Industrial Grade Switches Product Line Bulletin Motor Starter Switches and NEMA Enclosures Safety Disconnect Switches Motor Starter Switch Features 10 YEAR LIMITED UL 508 Listed CUL per CSA Specification C22.2 No. 14 Certified Topped roll-over brass bushings secure yoke to device Robust, full-face, nickel-plated, brass mounting yoke offers exceptional strength and corrosion-resistance Large toggle is easy to turn ON/OFF with gloved hand 30A & 40A Motor Starter Switch Features Oversized Valox® toggle is capable of withstanding extreme impact, harsh chemical attack, and prolonged ultraviolet exposure Mounting yoke is permanently marked with catalog number, amperage, voltage and horsepower ratings for easy identification #10 triple-combination nickel-plated terminal screws resist loosening from vibration and facilitates tightening to proper torque ranges Internal chamber barriers prevents flash-over between contact sets Impact-resistant Rynite® face and base Strip gauge and terminal identification permanently marked on base of device Positive toggle ON/OFF actuation is accomplished by the toggle riding on a single-piece, non-conductive, non-tracking, thermoplastic pivotal link designed to minimize friction, resists wear, and high-use deterioration. COMPONENT Side and back wired terminal screws accept up to a #10 AWG solid copper wire Multiple termination design accepts back and side wiring, terminal clamps, or ring terminals High-performance silver-cadmium oxide contacts minimize wear and erosion. .062” Nickel-Plated Brass Base Rynite® Toggle Valox® Face Rynite® Contacts .031” Thick Silver Cadmium Oxide Triple Drive #10 Terminal Screws #10-32 Nickel-Plated Brass Slotted; Undercut Binding Head Design Assembly Topped Roll-Over Brass Bushings NEMA ANSI STANDARDS & CERTIFICATIONS UL UL Fed Spec CUL per CSA ⻬ Listed WS896E C22.2 No.14 NOM ⻬ 508 #E63969 Not Applicable #E63969 #057 C-73 High-conductive nickel-plated brass terminal screws improve current flow and prolong component life. Insulating barriers provide terminal isolation between phases NEMA 1 and NEMA 3R enclosures with or without switches are available. DESCRIPTION Mounting Yoke WD1& WD6 1 Thick walled Rynite® housing and interlocking face encapsulates and protects internal mechanism in extreme and harsh industrial environments CAT. NO. RATING MS302 30AMP 600V AC 2 HP 120V 5 HP 240V 10HP 480V 15 HP 600V 30AMP 600V AC 3 HP 120V 71/2 HP 240V 15HP 480V 20 HP 600V 40AMP 600V AC 2 HP 120V 5 HP 240V 10HP 480V 15 HP 600V 40AMP 600V AC 3 HP 120V 71/2 HP 240V 15HP 480V 20 HP 600V MS303 MS402 MS403 To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: AC HORSEPOWER RATING www.leviton.com Motor Starter Switch Features 10 YEAR LIMITED UL 508 Listed CUL per CSA Specification C22.2 No. 14 Certified Large toggle is easy to turn ON/OFF with gloved hand Topped roll-over zinc-plated brass bushings secure yoke to device Thick walled Rynite® housing and interlocking face encapsulates and protects internal mechanism in extreme and harsh industrial environments Insulating barriers provide terminal isolation between phases 60A Motor Starter Switch Features Impact-resistant Rynite® face and base Front or back wired terminal screws accept up to a #4 stranded AWG or #10 solid AWG copper wire Internal chamber barriers prevents flash-over between contact sets Positive toggle ON/OFF actuation is accomplished by the toggle riding on a single-piece, non-conductive, non-tracking, thermoplastic pivotal link designed to minimize friction, resists wear, and high-use deterioration. Zinc-plated lug-type terminal screws, hold conductors securely in place assuring an excellent electrical connection and delivery of maximum current to the designated large (.218”) diameter contact. COMPONENT DESCRIPTION Mounting Yoke .062” Nickel-Plated Brass Base Rynite® Toggle Valox® Face Rynite® Figure 1 – Cat. Nos. MS602-BW/FW Line 600VAC .046” Thick Silver Cadmium Oxide Terminal 5/16-24 Assembly Topped Roll-Over Zinc-Plated Brass Bushings CAT. NO. T2 OFF Motor T1 NEMA 3R enclosure is carbon steel with polyester powder coating over phosphatized surface for a highly durable finish Figure 2 – Cat. Nos. MS603-BW/FW Line L3 Line L2 T2 Line L1 T1 Line 600VAC T3 OFF Motor RATING AC HORSEPOWER RATING MS602 60AMP 600V AC 2-Pole 1ø 10 HP 240V 15HP 480V 20 HP 600V MS603 60AMP 600V AC 3-Pole 3ø 10 HP 240V 25HP 480V 30 HP 600V Zinc-Plated Steel, Triple-Combination NEMA ANSI STANDARDS & CERTIFICATIONS UL UL Fed Spec CUL per CSA ⻬ Listed WS896E C22.2 No.14 NOM ⻬ 508 #E63969 Not Applicable #E63969 #057 C-73 L2 L1 Contacts WD1& WD6 Cam break action opens & closes, high-performance, double contacts used to absorb high energy in the make-break-cycle, run cooler and more efficiently prolonging and extending switching performance. To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com 2 30 & 40A 600V AC Industrial Grade, Back & Side Wired-MSS Devices, SideWired,BusBarTermination& RingTerminal-WS Devices ENVIRONMENTAL FLAMMABILITY OPERATING TEMP. Rated V0 per UL94 -40C to 65C ELECTRICAL DIELECTRIC VOLTAGE OVERLOAD UL 508 TEST Withstands 2200V for 1min TEMP. RISE 50 cycles of overload at 6 times rated current ENDURANCE 50 C max UL 508 6,000 cycles inductive at full rated motor type load. Dual rated current General and Manual Motor Control MECHANICAL Industrial Grade Motor Starter Switches TERMINAL I.D. T1, T2, T3, L1, L2 & L3 marked on back of device MS302-S TERMINAL ACCOMM. PRODUCT I.D. Ratings are permanently stamped on device strap #10 -#8 AWG MS303 MS403 TOGGLE COLOR CERTIFICATION CUL UL Fed Spec per CSA NOM WS896E C22.2 No.111 NEMA WD-1 ANSI & WD-6 C-73 UL 508 #E63969 TORQUE 20 inch pounds N1303 DOUBLE-POLE SINGLE-THROW 10 YEAR LIMITED Not Applicable #E63969 #057 WS402 N3303 AC HP RATING THREE-POLE SINGLE-THROW AC HP RATING 30A 600V AC, Motor Starting Switch Switch Only Switch Only Switch in NEMA 1 Switch in NEMA 3R 2HP 120V Enclosure Enclosure Black MS302 Black (short toggle) MS302-S N1302 – 5HP 240V 10HP 480V 15HP 600V N3302 – Switch in NEMA 1 Switch in NEMA 3R 3HP 120V Enclosure Enclosure MS303 MS303-S N1303 – N3303 – 71/2HP 240V 15HP 480V 20HP 600V 40A 600V AC, Motor Starting Switch Black 2HP 120V 5HP 240V 10HP 480V 15HP 600V MS402 40A 600V AC, Welder Starting Switch 3HP 120V 71/2HP 240V 15HP 480V 20HP 600V MS403 (Terminal Screws Packaged Separately) Recognized Component for OEM use. Black WS402 NEMA 1 STEEL ENCLOSURE WITHOUT SWITCH 30 Amp MS Switch 5HP 240V NEMA 3R ENCLOSURE WITHOUT SWITCH 30 or 40 Amp MS Switch – – 302 STAINLESS STEEL LOCKOUT WALLPLATE w/ TAMPER-RESISTANT SCREWS & SPANNER TOOL 302 STAINLESS STEEL 2 Knockouts #1: 1/2”-11/4” Bottom #2: 1/2”- 3/4” Bottom 2 Knockouts 1/2” & 3/4” Top & Bottom EnclosureDimensions See page 4 84001-LOK 1.50 (38.1 mm) .96 (24.4 mm) .96 (24.4 mm) .900 (22.9 mm) 2.47 (62.7 mm) 2.0 (50.8 mm) 2.47 (62.7 mm) 2.0 (50.8 mm) 1.20 (30.5 mm) 2.45 (62.2 mm) 1.00 (25.4 mm) 2.97 (75.4 mm) 3.11 (78.7 mm) 1.14 (28.96 mm) 1.38 (35.0 mm) 84009-40 K.O. TOP & BOTTOM 2.19 (55.6 mm) 3.8 (96.5 mm) 3.8 (96.5 mm) 1.87 (47.5 mm) 1.50 (38.1 mm) 84001-40 Lock Purchased Seperately 2.40 (61.0 mm) N33NC 5.60 (142.2 mm) N13NC 1.20 (30.5 mm) TOP BACK MS302-S Toggle Length, .64 (16.3 mm) MS302 & MS303 3 MS402 & MS403 WS402 To learn more about Leviton devices or for answers to technical questions call our Techline at N13NC 1-800-824-3005 or visit us at: For N3303 dimensions see page A12. www.leviton.com 60A 600V AC 10 YEAR LIMITED Industrial Grade, Front & Back Wired-MSS Devices ENVIRONMENTAL FLAMMABILITY OPERATING TEMP. Rated V0 per UL94 -40C to 65C ELECTRICAL DIELECTRIC VOLTAGE OVERLOAD UL 508 TEST Withstands 2200V for 1min TEMP. RISE 50 cycles of overload at 6 times rated current ENDURANCE 50 C max UL 508 6,000 cycles inductive at full rated motor type load. Dual rated current General and Manual Motor Control CERTIFICATION MECHANICAL TERMINAL I.D. T1, T2, T3, L1, L2 & L3 marked on back of device TERMINAL ACCOMM. #10 -#4 AWG PRODUCT I.D. Ratings are permanently stamped on device strap TOGGLE COLOR UL 508 #E63969 25 inch pounds #E63969 #057 N3603 - Without Front Cover N3603 DOUBLE-POLE SINGLE-THROW Not Applicable AC HORSEPOWER RATING THREE-POLE SINGLE-THROW AC HORSEPOWER RATING 60A 600V AC, Motor Starting Switch Back-Wired Switch Only Black Front-Wired Switch Only MS602-BW Front-Wired Switch in NEMA 3R Enclosure MS602-FW 10HP 240V 15HP 480V 20HP 600V N3602 Back-Wired Switch Only Front-Wired Switch Only Front-Wired Switch in NEMA 3R Enclosure MS603-BW MS603-FW N3603 10HP 240V 25HP 480V 30HP 600V 1.71 (43.3mm) 1.37 (34.9mm) NEMA 3R ENCLOSURE WITHOUT SWITCH 40 or 60 Amp MS Switch 3.43 (87.2 mm) 1.70 (43.3 mm) 0.96 (24.3mm) LEVITON CAT.NO. MS603 PEND. THREE PHASE MANU MOTO CONTR THREE PHASE 10HP-240VAC 25HP-480VAC. 30HP-600VAC 60A-600V.A.C GENERAL PURPOSE 3.75 (95.2 mm) 3.28 (83.3 mm) 2.38 (60.3 mm) 3.75 (95.2mm) 3.28 (83.3mm) 60A-600V.A.C GENERAL PURPOSE 10HP-240VAC 25HP-480VAC. 30HP-600VAC MANU MOTO CONTR 2.38 (60.3mm) PAT. 2 Knockouts #1: 1/2”-11/4” Bottom #2: 1/2”- 3/4” Bottom C US 1.37 (34.9 mm) 3.43 (87.2mm) MS602-BW & MS603-BW .05 (1.3 mm) MS602-FW & MS603-FW N36NC 6.3 (160.0 mm) 4.33 (109.9 mm) 4.30 (109.2 mm) 4.3 (109.2 mm) X.01 X.01 8.1 (205.7 mm) 0.05REF NO PAINT/FINISH ON THREAD(4) 5.5 (139.7 mm) 6.15 (156.2 mm) 3.86 (98.0 mm) 4.13 (105 mm) 4.13 (105 mm) #10-32 TAP 1.23 (31.3 mm) .13 (3.2 mm) Industrial Grade Motor Starter Switches MS602-FW TORQUE CUL UL Fed Spec per CSA NOM C22.2 No.111 WS896E NEMA WD-1 ANSI & WD-6 C-73 6.15 (156.2 mm) SIDE FRONT N3303 - See page 3 for Product Information To learn more about Leviton devices or for answers to technical questions call our Techline at INTERIOR SIDE N3603 1-800-824-3005 or visit us at: www.leviton.com 4 Disconnect Switch Features 2 YEAR LIMITED 30 Amp, Non-Fused Safety Disconnect Switch Captive Stainless Steel Cover Screws Won’t Fall Out When Cover is Open Engineered to IP65 Standards High Impact, Non-Conductive Valox® Cover, Housing and Handle 2-Top Knock-outs for Wiring Flexibility Safety Disconnect Switch Features Factory-Installed Cover Gasket Enclosure Rated to UL and IEC Watertight Standards Type 3R, 4X, and 12K IP65 (4) Mounting Feet Included (5 Position Settings) DS30-AX UL94 V-0 Self-Extinguishing, Flame Retardant Rating Liquid-tight Conduit Fitting Can Be Installed for Top or Bottom Feed 1 Fitting Supplied 30 Amp - 1” Metal Ground Frame 1 Factory Installed Auxiliary Contact (Normally Open - 10 Amp) Additional Auxiliary Contacts Available (Normally Closed - 10 Amp) IEC Non-Fused Switch Mechanism Drill Mark for Side Conduit Entry Neutral Buss Lockout Mechanism Integrated with Handle Ground Buss High-Visibilty Handle can be Locked and Tagged in the OFF Position (even when cover is off) Drill Mark for Back Conduit Entry STANDARDS & CERTIFICATIONS Saftey Disconnect Switches UL 98 Fused (Including 100A Non-Fused -DS) E63969 5 UL 508 Non-Fused CSA C22.2 No. 14 NOM CE IEC 947-3 ⻬ ⻬ ⻬ ⻬ To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com Disconnect Switch Features Watertight Safety Disconnect Switches 2 YEAR LIMITED 30 Amp Fused, 60 & 100 Amp (Fused & Non-Fused) Liquid-tight conduit fitting can be installed for top or bottom feed Red “pistol grip” handle provides visual confirmation of switch’s status One fitting supplied: • 30 Amp - 1” • 60 Amp - 1-1/2” • 100 Amp - 2” Integrated lockout handle meets OSHA safety regulations Stainless steel screws are captive and will not fall out when cover is opened Handle with padlock installed Circuit identification pad for means of identifying specific equipment loads Fused Models Accept “Class J” Time-Delay Fuses DS60-FAX Generous wiring space for top to bottom wiring Pre-wired grounding plates (top and bottom of enclosure) connect to metal conduit grounding system Brass threaded inserts will not strip, provide higher torque, and form tighter seal between back box and cover Disconnect switch with integrated fuse holder offers proven performance in a compact package • Fused cartridges accept “Class J” fuses (not included) • 1 Factory installed Auxiliary Contact (Normally Open - 10 Amp) • Additional Auxiliary Contact Available (Normally Closed - 10 Amp) • Easily accessible neutral and ground terminal blocks Rugged hinge mechanism pivots 180º for easy access during installation and maintenance Safety Disconnect Switch Features Impact UV and chemical-resistant Valox enclosure rated to UL and IEC watertight standards • Type 3R, 4X & 12K • IP67 DS60-FAX STANDARDS & CERTIFICATIONS Saftey Disconnect Switches UL 98 Fused (Including 100A Non-Fused -DS) E63969 UL 508 Non-Fused CSA C22.2 No. 14 NOM CE IEC 947-3 ⻬ ⻬ ⻬ ⻬ To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com 6 Specifications 2 YEAR LIMITED Watertight Safety Disconnect Switches Safety Disconnect Switches Engineered to UL & IEC Watertight Standards DS30-AX Engineered to IP65 Water Jetting Standards Ordering Information AMPS MAX VOLTAGE 30 60 100 600V AC 600V AC 600V AC CATALOG NO. ELECTRICAL Device Current Applied Ground Path Integrity 30 A 60 A 100 A Current Interrupting FUSED DS30-AX DS60-AX DS100-AX DS30-FAX DS60-FAX – 120V AC 208V AC 240V AC 480V AC 600V AC 3Ø Y120/208V AC 3Ø 240V AC 3Ø 480V AC 3Ø 600V AC 1 5 2.5 5 NA 5 5 15 15 2 20 10 20 20 20 20 40 40 ENVIRONMENTAL Mold Stress Relief 70°C for 7 hours Knockout Test Remains in place with 20 lb push Flammability Crush 100 lb Impact 1.2 lb steel ball dropped from 5 ft Rain (3R) per UL 50 Cold Impact Same as above, after conditioning to -35°C Strength of Insulating Base and Support 110% of specified tightening torque on terminal screws Pullout 18 lb pull on internal wires MAX. HP RATINGS PER UL508 NON-FUSED SAFETY DISCONNECT SWITCHES DS30-AX DS60-AX DS100-AX VOLTS NR = Not Rated 60 A 2 min 120 A 4 min 200 A 6 min Certified for current interrupting at full-rated current and voltage 1000 V plus twice rated voltage for 1 minute Dielectric NON-FUSED MECHANICAL Duration 6000 operations at rated current and voltage (Power factor 0.75 – 0.80) Endurance 7 DS100-AX (Non-Fused) DS60-FAX (Fused) 5 25 15 25 20 25 30 50 50 VOLTS 120V AC 208V AC 240V AC 480V AC 600V AC 3Ø Y 120/208V AC 3Ø 240V AC 3Ø 480V AC 3Ø 600V AC Hosedown (4X) per UL 50 Dust (12K) per UL 50 Gasket Aging UV Resistance Operating Temperature MAX. HP RATINGS PER UL508 FUSED SAFETY DISCONNECT SWITCHES DS30-FAX DS60-FAX 2 7.5 3 15 20 7.5 7.5 15 20 NA = Not Available To learn more about Leviton devices or for answers to technical questions call our Techline at V2 or better per UL 94 or CSA 22.2 No 0.6; V-0 for watertight enclosure Water spray @ 5 psi from all sides for 1 hr Water spray @ 65 gal/min for 5 minutes Cement Dust Circulated @ 1000 ft/minute for 5 minutes 70°C for 168 hours Exposed plastic materials are UV stabilized -40°C to +60°C (-40°F to +140°F) 1-800-824-3005 or visit us at: NR 15 NR NR NR 15 15 30 50 www.leviton.com Specifications Watertight Safety Disconnect Switches 2 YEAR LIMITED Engineered to UL & IEC Watertight Standards Enclosures are Type 3R, 4X & 12K, IP67* to UL 508 for Non-Fused and UL 98 for Fused* ■ Certified to CSA Standard C22.2 number 14 ■ Classified to IEC Standard 947-3 ■ CE marking per low-voltage directives 73/23/EEC, 93/68/EEC ■ ■ Listed Material Specifications 30 & 60 Amp Switch, Fused 30 Amp Switch, Non-Fused Housing Cover Housing Base Housing Gasket Sealing Gasket Handle Screw handle Conduit Grounding Plate Conduit Hub Switch Switch Terminal Contacts Internal Screws Housing Screws Mounting Feet Ground Terminal Ground Terminal Block Neutral Terminal Neutral Terminal Block Valox 357 Valox 357 Solid Chloroprene Solid Chloroprene Valox 357 Stainless Steel Zinc-Coated Steel Die-Cast Zinc Nylon Brass Zinc-Coated Steel Stainless Steel Valox 357 Plated Brass/Steel Nylon Plated Brass/Steel Nylon 60 & 100 Amp Switch, Non-Fused PART Housing Cover Housing Base Housing Gasket Sealing Gasket Handle Screw handle Conduit Grounding Plate Conduit Hub Switch Switch Terminal Contacts Internal Screws Housing Screws Hinge Screws Mounting Feet Ground Terminal Ground Terminal Block Neutral Terminal Neutral Terminal Block PART MATERIAL Housing Cover Housing Base Housing Gasket Sealing Gasket Handle Screw handle Conduit Grounding Plate Conduit Hub Switch Switch Terminal Contacts Internal Screws Housing Screws Hinge Screws Fuse Holder Mounting Feet Ground Terminal Ground Terminal Block Neutral Terminal Neutral Terminal Block MATERIAL Valox 357 Valox 357 Solid Chloroprene Solid Chloroprene Valox 357 Stainless Steel Zinc-Coated Steel Die-Cast Zinc Reinforced Nylon Brass Zinc-Coated Steel Stainless Steel Stainless Steel Valox 357 Plated Brass/Steel Nylon Plated Brass/Steel Nylon MATERIAL Safety Disconnect Switches PART Valox 357 Valox 357 Solid Chloroprene Solid Chloroprene Valox 357 Stainless Steel Zinc-Coated Steel Die-Cast Zinc Reinforced Nylon Brass Zinc-Coated Steel Stainless Steel Stainless Steel Reinforced Nylon Valox 357 Plated Brass/Steel Nylon Plated Brass/Steel Nylon STANDARDS & CERTIFICATIONS Safety Disconnect Switches UL 98 UL 508 CSA Fused Non-Fused C22.2 No.14 ⻬ ⻬ ⻬ NOM CE IEC 947-3 ⻬ ⻬ ⻬ Valox® is a registered trademark of GE. * IP Ratings & UL Standards CATALOG NO. IP RATING UL STANDARD DS30-AX DS60-AX DS100-AX DS30-FAX DS60-FAX IP65 IP67 IP67 IP67 IP67 UL508 UL508 UL98 UL98 UL98 To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com 8 Dimensions Watertight Safety Disconnect Switches 7.95 (202 mm) 8.78 (223 mm) 7.12 (180.9 mm) 7.83 (199 mm) 6.3 (160 mm) 5.12 (130 mm) 7.48 (190.1 mm) 3.11 (79.1 mm) 30 AMP FUSED & 60 AMP NON-FUSED ON 7.28 (184.9 mm) OFF 0.44 (11.1 mm) 5.24 (133.1 mm) 3.26 (82.8 mm) 6.24 (158.5 mm) 7.28 (90.9 mm) 30 AMP NON-FUSED 9 To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com 11.69 (297 mm) OFF 10.86 (275.9 mm) 12.52 (318 mm) 10.71 (271.9 mm) 8.86 (225 mm) 11.59 (294.4 mm) 6.85 (174.1 mm) Safety Disconnect Switch Dimensions ON Dimensions & Accessories Watertight Safety Disconnect Switches 8.54 (217 mm) 7.71 (195.9 mm) 8.94 (227.2 mm) 18.54 (471 mm) OFF 17.72 (450 mm) 16.73 (424.9 mm) 12.88 (327.1 mm) 17.65 (448.4 mm) 60 AMP FUSED & 100 AMP NON-FUSED Accessories for Safety Disconnect Switches & Mechanical Interlocks Auxiliary Contacts (Normally Closed - 10 Amp) -Leviton Mechanical Interlocks and Disconnect Switches automatically ship with one factory installed auxiliary contact, normally open. -A second auxiliary contact may be added. Select from the table below. APPLICATION CATALOG NO. 30 Amp (Non-Fused) 3145801 30 Amp (Fused) 60 & 100 Amp (Fused or Non-Fused) 3145807 Safety Disconnect Switch Dimensions & Accessories ON 16.89 (428.9 mm) 5.71 (145 mm) 3.70 (94.1 mm) 8.49 (215.7 mm) 14.88 (378 mm) 9.37 (238 mm) 6.89 (175 mm) 3145807 3145801 To learn more about Leviton devices or for answers to technical questions call our Techline at 1-800-824-3005 or visit us at: www.leviton.com 10 Leviton Manufacturing Co., Inc. 59-25 Little Neck Parkway, Little Neck, NY 11362-2591 Telephone: 1-800-323-8920 • FAX: 1-800-832-9538 Tech Line (8:30AM-6:00PM E.S.T. Monday-Friday): 1-800-824-3005 Leviton Manufacturing of Canada, Ltd. 165 Hymus Boulevard, Pointe Claire, Quebec H9R 1E9 Telephone: 1-800-469-7890 • FAX: 1-800-563-1853 Leviton S.A. de C.V. General Arista 54-A Col. Argentina, Mexico D.F., C.P. 11270 Telephone: 011-525-386-1131, 011-525-386-2052 • FAX: 011-525-386-1797 Visit us on the web at: www.leviton.com © Copyright 2002 Leviton Manufacturing Co., Inc. All rights reserved. sa