The Right Connection for Class I Division 2 Certified For Hazardous Locations For applications that require C1/D2 certification, B+B SmartWorx has a selection of connectivity and communication solutions designed to operate in hazardous environments. Class I/Division 2 Data Communications Equipment for Safe Operation & Regulatory Compliance Class I/Division 2 safety certification is a mandated requirement for devices in many industrial applications, and for good reason. A Class I/Division 2 hazardous location is defined as an area in which flammable gases, vapors or liquids may potentially be present. A Class I/Division 2 certified device is specifically designed and manufactured to reduce the risk that it will produce an electrical discharge that could serve as the ignition point for a fire or explosion. From serial servers and media converters to network gateways and switches, B+B SmartWorx designs and builds the Class I/Division 2 certified connectivity equipment you need to meet regulatory standards and establish safe, reliable data communications in potentially hazardous environments. Certified For Hazardous Locations 2 Wzzard™ Intelligent Sensor Nodes (WSD series) • Connect your existing sensors and make them wireless (standard analog input, digital input/output, thermocouple) • Integrated motion accelerometer and temperature sensors • Ultra low power – 802.15.4e SmartMesh IP or Bluetooth 4.0 LE • Communicates with Spectre Network Gateway via scalable and reliable wireless mesh networks • Battery powered nodes • Read or configure nodes via Android, iOS tablets, smart phones using the Wzzard appplication • Rugged, IP67, fiber reinforced polyester PBT enclosure • Wide operating temperature Wzzard™ APPLICATION STARTER Kits (Energy Monitoring and more...) • Includes: Spectre™ gateway, Wzzard™ mesh nodes, application specific sensors, dashboard application and accessories. Certifications - SENSOR NODES & APPLICATION KITS UL/CSA, Class I/Division 2, Groups A,B,C,D EN55022 CISPR Class A IEC EN 61000-4-2 – ESD +/- 8kV air, +/- 4kV contact IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CI IEC EN 61000-6-2 – Generic immunity standards for heavy industrial environments IEC EN 61000-6-4 – Emission standards for heavy industrial environments Industry Canada – RSS210 FCC Part 15 Class A, Part 15.247 CE RoHS Directive (lead-free) IEC 60068-2-6:2007 – Vibration EN 60255-21-1 – Vibration IEC 60068-2-27:2008 – Shock EN 60255-21-2 – Shock WEEE Class I/Division 2 Rated Spectre™ Cellular Routers (RT3G series, RTLTE series) • • • • • • Cellular router technologies: LTE and 3G Ethernet, USB, I/O, Serial RS-232/422/485 WiFi access point Wide operating temperature Modbus compatible Certified for use with multiple North American & Canadian carriers Certifications - Cellular Routers UL Class I/Division 2 ETSI EN 300 342 – Immunity ETSI EN 301 489-1 V1.8.1 ETSI EN 301 511, v9.0.2 ETSI EN 301 908-1&2, v3.2.1 EN55022 Class B – Emission (RT3G series) EN55022 Class A – Emission (RTLTE series) IEC EN 60950 – Safety IEC EN 60747 – Isolation FCC Part 15 CE CARRIERS: Verizon, AT&T, T-Mobile, Rogers, Telus (RT3G series) Verizon, AT&T, T-Mobile (RTLTE series) bb-smartworx.com 3 (Shown: 1 base I/O unit, with 3 expansion I/O modules) Industrial Wireless I/O (ZZxD series) IP67 INDUSTRIAL Radio Modems & I/O (Xtreme™ ZXT series) • • • • • • Instant plug-n-play set-up 1-to-1 or 1-to-multipoint AES encryption security Modbus compatible Wide temperature IP67 rated case for outdoor applications Certifications - RADIO MODEMS & I/O - ZXT series UL, cULus, Class I/Division 2, Groups A,B,C,D (File # E245458) NEMA TS2 (Radio Modems) EN55022: 2006 Class A Emissions IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-6 – CI IEC EN 61000-6-1 – Immunity- residential, commercial, light industrial environments FCC Class A FCC ID (ZXT9-RM series Radio Modems – OUR-9XTEND) FCC ID (ZXT24-RM series Radio Modems – OUR-XBEEPRO) CE RoHS Directive (lead-free) Certified For Hazardous Locations 4 • Low latency 15mS response rate • 128/256-bit AES encryption • Software selectable: RF transmit power & over-the-air data rates • Modbus compatible; Wide temperature • Monitor and control analog/digital I/Os with C1/D2 snap-on modules Certifications - STANDARD I/O - ZZxD series UL/cULus, Class I/Division 2 (File # E24545), UL508 (File# E222870) C1/D2 models: ZZ24D-Nx-SR (2.4 GHz, short range), ZZ9D-Nx-LR (900 MHz,long range) C1/D2 snap-on modules: ZZ-2AI2AO, ZZ-4AI, ZZ-4AO, ZZ-4AO-2, ZZ-4DI4DO-DCT, ZZ-4DI4DO-DCT1, ZZ-4RTD1, ZZ-8DI-DC, ZZ-8DO-R, ZZ-8DO-T, ZZ-8DO-T1, ZZ-PROG1-USB IEC EN 61000-6-2 – Immunity standards - industrial environments FCC Part 15 Class A CE RoHS Directive (lead-free) Long Range Radio Modem & Kit (ZP9D-115RM-LR model) • • • • • • Up to 14mi/22km (40mi/64km w/optional antenna) AES encryption security Modbus compatible Wide temperature Dual power supply IP30 case Radio Modem Complete Kit Certifications - standard RADIO MODEM & KITS UL, cULus, Class I/Division 2, Groups A, B, C, D (File# E245458) EN55022 CISPR Class B Emissions IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CS IEC EN 61000-4-8 – PFM IEC EN 61000-4-11 – Voltage Dips & Interruptions IEC EN 61000-6-1 – Immunity- residential, commercial, light industrial environments FCC Part 15 Class B CE RoHS Directive (lead-free) Ultra-Slim Ethernet Switches Industrial Wired Routers (ESW100 series) • • • • • 5 or 8 ports Copper, LC, SM/MM fiber port combinations Redundant AC/DC power inputs IP30 metal case, DIN or 6-way panel mount Ultra compact, slimline CERTIFICATIONS - ETHERNET SWITCHES - ESW100 series UL/cUL, Class I/Division 2, Groups A,B,C,D EN55022 – CISPR Class B Emissions IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CI IEC EN 61000-6-2 – Immunity standards - industrial environments FCC CE RoHS Directive (lead-free) IEEE 802.3x – Flow Fontrol IEEE 802.3u – 100Base-TX & 100Base-FX Fast Ethernet IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Free Fall (Spectre™ ERT31x series) • Secure VPN with IPsec, OpenVPN, or L2TP • DHCP, NAT, NAT-T, DynDNS, NTP, VRRP • Firewall: filtering of addresses, ports, protocols • Remote configuration and management • VLAN 802.1Q: virtual LAN • Wide temperature range: -40 to 75°C CERTIFICATIONS - WIRED ROUTERS - ERT31x series Class I/Division 2 NEMA TS1/TS2 ETSI EN 301 511, v9.0.2 ETSI EN 301 908-1&2, v3.2.1 ETSI EN 301 489-1 V1.8.1 EN 60950-1:06 ed.2 + A11:09 + A1:10 FCC CE RoHS Directive (lead-free) IEC 60068-2-27 – Shock IEC 60068-2-6 – Vibration Power-over-Ethernet (PoE/ PoE+) Switches (EIRHP305-T, EIRP305-24V-T models) WIDE TEMPERATURE Ethernet Switches (ESW200 series) • • • • • 5 or 8 ports Copper, LC/SC/ST, SM/MM fiber port combinations Redundant AC/DC power inputs IP30 metal case, DIN or 6-way panel mount Wide temperature CERTIFICATIONS - ETHERNET SWITCHES - ESW200 series UL/cUL, Class I/Division 2, Groups A,B,C,D EN55022 – CISPR Class B Emissions IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CI IEC EN 61000-6-2 – Immunity standards - industrial environments FCC CE RoHS Directive (lead-free) IEEE 802.3x – Flow Fontrol IEEE 802.3u – 100Base-TX & 100Base-FX Fast Ethernet IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Free Fall • • • • • • Simplifies powering of remote devices Dual power inputs and alarm output IP30 metal case, DIN or panel mount Wide temperature 24 or 48VDC power (EIRP305-24V-T) 48VDC power (EIRHP305-T) CERTIFICATIONS - PoE SWITCHES - #EIRHP305-T, #EIRP305-24V-T UL/cULus, Class I/Division 2, Groups A,B,C,D (#Model EIRP-24V-T) UL/cUL, Class I Division 2, Groups A,B,C,D File# E173795 (#Model EIRHP-305-T) FCC CE RoHS directive (lead-free) EN 61000-4-2 – ESD EN 61000-4-3 – RFI EN 61000-4-4 – EFT EN 61000-4-5 – Surge EN 61000-4-6 – CI EN 61000-4-8 – PFM EN 61000-6-2 – Immunity standards - industrial environments EN 61000-6-4 – Emission standards - industrial environments IEEE 802.3 – 10Base-T Ethernet IEEE 802.3u – 100Base-TX & 100Base-FX Fast Ethernet IEEE 802.3x – Flow Control & Back Pressure IEEE 802.3af – Power-over-Ethernet IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Free Fall bb-smartworx.com 5 Ethernet Serial DEVICE Servers (VESR900 series) • • • • Multi-serial-port (MEI), Ethernet port options Automatically monitors, reconnects communications Ethernet pass-through port option (VESR92x models) Wide temperature CERTIFICATIONS - Serial Servers - VeSR900 series UL Listed (File# E222870) UL Class1/Division 2 Groups A,B,C,D HAZLOC (File# E245458) NEMA TS2 (Model# VESR901) FCC CE RoHS Directive (lead-free) Auto-negotiation & Auto MDI/MDX IEEE 802.3, 803.u – (1) 10/100 Ethernet Port ((VESR92x models) Ethernet Protocol Gateways Modbus Ethernet Gateways (MESR900 series) • • • • • Modbus TCP, RTU & ASCII Serial/Ethernet, master/slave flexibility Up to 16 Modbus TCP masters Ethernet pass-through port option (MESR92x models) Wide temperature CERTIFICATIONS - MODBUS Gateways - MeSR900 series UL Listed (File# E222870) UL Class1/Division 2 Groups A,B,C,D, HAZLOC (File# E245458) NEMA TS2 (Model# MESR901) FCC CE RoHS Directive (lead-free) Auto-negotiation & Auto MDI/MDX IEEE 802.3, 803.u – (1) 10/100 Ethernet Port ((VESR92x models) Ethernet Media Converters (EIR-M-ST, EIR-M-SC, EIR-S-SC models) (VFG series) • Protocol converter, data logger, web interface with virtual HMI - all in one • Integrate multi-vendor systems, devices, protocols • Built-in driver list for PLC, PC, SCADA system mapping • Converts multiple protocols simultaneously (up to 9 protocols with expansion card) CERTIFICATIONS - PROTOCOL GATEWAys - VFG1000/2000/3000 series cULus Listed, Class I/Division 2, Groups A,B,C,D, UL Listed, UL508 EMC EN 61326 – Immunity - control. lab, test & measurement IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CS EN 55011 – RF - industrial, scientific, medical, arc welding FCC CE RoHS Directive (lead-free) IEC 61010-1 – Measurement/Control/Laboratory 6 • • • • • • Convert copper signals to fiber 10/100Base Redundant 10-48VDC power inputs Auto negotiation - data rate & duplex modes MDI/MDI-X (auto cross-over) Wide temperature; IP30 metal case CERTIFICATIONS - MEDIA CONVERTERS - #EIR-M-ST, #EIR-M-SC, #EIR-S-SC UL60950-1, Class I/Division 2, Groups A,B,C,D for Hazardous Locations NEMA TS1/TS2 EN60950-1 IEC EN 61000-4-2 (-3, -4, -5, -6, -8, -11) IEC EN 61000-6-2 – Immunity standards - industrial environments IEC EN 61000-6-3 – Emission - residential, commercial, light industrial environments FCC Part 15, Class A CE RoHS Directive (lead-free) IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Free Fall Hardened Converters & Repeaters (485DRCi-PH, 232OPDRi-PH, 485OPDRi-PH, FOSTCDRi-PH-xx models) • • • • • 3-way isolation Wide temperature Modbus compatible IP30 case Power utility, substation, oil, gas, traffic & more Class I/Division 2 Rated CERTIFICATIONS - SERIAL Converters & REpeaters - #485DRCi-PH, #232OPDRi-PH, #485OPDRi-PH, #FOSTCDRi-PH-xx UL, Class I/Division 2, File: E245458 NEMA TS1/2 (Models 485DRCI-PH, 232OPDRI-PH, 485OPDRI-PH, FOSTCDRI-PH-MT) IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CS IEC EN 61000-4-12 – Oscillatory IEC EN 61000-4-16 – Disturbance IEC EN 61000-4-17 – Ripple FCC CE RoHS Directive (lead-free) IEEE 1613 C37.90. (-1, -2, -3) – Electrical Power Substations IEC 61850-3 – Power Utility Automation IEC 60068-2-1 – Cold IEC 60068-2-2 – Dry Heat IEC 60068-2-30 – Damp Heat/Cyclic IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Free Fall INDUSTRIAL USB Hubs Class I/Division 2 Rated Accessories (UHRx04 series) • • • • • • USB 1.0/2.0 industrial--grade hubs High retention USB connectors Level 4 ESD protection - 15kV Wide temperature 4kV isolation (#UHR204) IP30 metal case CERTIFICATIONS - USB HUBS - #UHR204, #UHR304 UL Listed, Class I/Division 2, Groups A,B,C,D (File: E245458) Ind. Cont. Eq. for HAZ LOC, 3HTV, Temp Code:T4A IEC EN 61000-4-2 – ESD IEC EN 61000-4-3 – RFI IEC EN 61000-4-4 – EFT IEC EN 61000-4-5 – Surge IEC EN 61000-4-6 – CS IEC EN 61000-4-8 – PFM IEC EN 61000-6-2 – Immunity standards - industrial environments FCC Class B CE RoHS Directive (lead-free) IEC 60068-2-6 – Vibration IEC 60068-2-27 – Shock IEC 60068-2-32 – Drop Contact B+B, your distributor or channel partner for details. • • • • • Power supplies NEMA TS1/TS2 enclosures & back panels Cabling Terminal blocks DIN rail Certified For Hazardous Locations 7 Rugged, Reliable Class I/Division 2 Data Networking Global Reach for Global Support In addition to our U.S. manufacturing, distribution, and customer support operations, we have a manufacturing facility located in the Czech Republic. Our European headquarters in Ireland provides service, support and product availability for customers in Europe, the Middle East, and Africa through a network of more than 40 qualified distributors. B+B SmartWorx products are also available around the world through our expanding network of channel partners, including value-added resellers and system integrators. All B+B SmartWorx Ethernet products carry a limited life-time warranty and a 30-day 100% satisfaction return policy. Learn how B+B SmartWorx can create an Ethernet-based solution for you by visiting us online or contacting us directly. Find B+B products in more than 60 countries around the world Talk to your favorite distributor about B+B SmartWorx’ products, or to find a channel partner near you, please go to www.bb-smartworx.com Latin America-Carribean Contact: Fanny Scargle Phone: 1-727-797-0300 Cell: 1-727-480-5920 Email: fscargle@bb-smartworx.com Skype: fscargle 4715