ABB Motors and Generators Technical Data Sheet - DOL Project Location Department/Author Customer name Customer ref. Item name 1.00001 Our ref. Rev/Changed by A Saving ident untitled.xls Pages 1(3) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Definition Product Product code Type/Frame Mounting Rated output PN Service factor Type of duty Rated voltage UN Rated frequency fN Rated speed nN Rated current IN No-load current Starting current Is/IN Nominal torque TN Locked rotor torque TS/TN Maximum torque Tmax/TN Minimum torque Tmin/TN Speed at minimum torque Load characteristics (IEC 60034-2-1:2007) PLL determined from residual loss 19 20 21 22 23 Maximum starting time from hot 24 Maximum starting time from cold 25 Insulation class / Temperature class 26 Ambient temperature 27 Altitude 28 Enclosure 29 Cooling system 30 Bearing DE/NDE 31 Type of Grease 32 Sound pressure level (LP dB(A) 1m) 33 Moment of inertia J = ¼ GD2 34 Balancing 35 Vibration class 36 Position of terminal box 37 Terminal box entries; no, dimens. 38 Number of power terminals 39 Direction of rotation 40 Weight of rotor 41 Total weight of motor 42 Dimension drawing no. 43 44 45 Ex-motors 46 47 48 Option Variant Codes / Definition 49 50 51 52 53 54 55 Date of issue 11/04/2011 Data Unit Remarks TEFC, 3-phase, squirrel cage induction motor 3GAA 091 313-ASE M3AA 90 LB 2 IM1001, B3(foot) 2.2 kW 1 S1(IEC) 100% 415 VY ± 5 % (IEC 60034-1) 50 Hz ± 2 % (IEC 60034-1) 2890 r/min 4.3 A 2 A 7.2 Fullfilled IEC 60034-12 des. N,H 7.3 Nm 2.8 3.4 2.8 480 r/min Load % Current A Efficiency % Power factor 100 4.3 85.0 / IE2 0.83 75 3.4 85.5 0.78 50 2.6 84.5 0.69 Start 31 0.65 10 s 18 s F/B 40 °C 1000 m.a.s.l. IP55 IC411 self ventilated 6205-2Z/C3 - 6204-2Z/C3 63 0.0027 dB(A) kg-m2 Top CW or CCW 4 18 Remarks: Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC Guaranteed values on request kg kg at load ABB Motors and Generators Load Curves Project Location Department/Author Customer name Customer ref. Item name Our ref. Rev/Changed byDate of issue A 11/04/2011 Saving ident untitled.xls Pages 2(3) 1.00001 Product TEFC, 3-phase, squirrel cage induction motor Type/Frame Product code Rated output PN Type of duty M3AA 90 LB 2 3GAA 091 313-ASE 2.2 kW S1(IEC) 100% Voltage (V) Frequency (Hz) 415 50 Current IN (A) Speed (r/min) 4.3 2890 Power factor at PN 0.83 Efficiency (%) at PN 85 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 P2/Pn Current Efficiency Load characteristics (IEC 60034-2-1:2007) Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC Cosinus 1.3 1.4 ABB Motors and Generators Starting Curves Department/Author Our ref. Project Location Customer name Customer ref. Rev/Changed bDate of issue Saving ident Item name 1.00001 Pages A 11/04/2011 untitled.xls TEFC, 3-phase, squirrel cage induction motor M3AA 90 LB 2 3GAA 091 313-ASE Frequency (Hz) 2.2 kW Rated current IN S1(IEC) 100% Type of product Type/Frame Product code Rated output PN Type of duty Jmotor (kgm2) Jload (kgm2) 0.0027 Voltage (V) 100% Tstart/TN Speed (r/min) TN (Nm) 2890 7.3 Starting time (s) Speed (r/min) 415 2.8 3(3) 50 4.3 Voltage (V) Tstart/TN A 415V(100%) 2.8 Run-up time (s) Speed (r/min) Is/In 7.2 Is/In 7.2 Tmax/Tn 3.4 Tmax/Tn 3.4 4.5 9 4 8 3.5 7 3 6 2.5 5 2 4 1.5 3 1 2 0.5 1 Is/In n Ts/Tn Tload (Nm) Nbr. of consecutive starts 0 0 250 500 750 0 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 Speed (r/min) TMotorUn 415V TMotorU2 415V(100%) IMotorUn 415V IMotorU2 415V(100%) Load characteristics (IEC 60034-2-1:2007) Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC ABB Motors and Generators Technical Data Sheet - DOL Project Location Department/Author Customer name Customer ref. Item name 1.00002 Our ref. Rev/Changed by A Saving ident untitled.xls Pages 1(3) No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Definition Product Product code Type/Frame Mounting Rated output PN Service factor Type of duty Rated voltage UN Rated frequency fN Rated speed nN Rated current IN No-load current Starting current Is/IN Nominal torque TN Locked rotor torque TS/TN Maximum torque Tmax/TN Minimum torque Tmin/TN Speed at minimum torque Load characteristics (IEC 60034-2-1:2007) PLL determined from residual loss 19 20 21 22 23 Maximum starting time from hot 24 Maximum starting time from cold 25 Insulation class / Temperature class 26 Ambient temperature 27 Altitude 28 Enclosure 29 Cooling system 30 Bearing DE/NDE 31 Type of Grease 32 Sound pressure level (LP dB(A) 1m) 33 Moment of inertia J = ¼ GD2 34 Balancing 35 Vibration class 36 Position of terminal box 37 Terminal box entries; no, dimens. 38 Number of power terminals 39 Direction of rotation 40 Weight of rotor 41 Total weight of motor 42 Dimension drawing no. 43 44 45 Ex-motors 46 47 48 Option Variant Codes / Definition 49 50 51 52 53 54 55 Date of issue 11/04/2011 Data Unit Remarks TEFC, 3-phase, squirrel cage induction motor 3GAA 091 313-BSE M3AA 90 LB 2 IM3001, B5(flange) 2.2 kW 1 S1(IEC) 100% 415 VY ± 5 % (IEC 60034-1) 50 Hz ± 2 % (IEC 60034-1) 2890 r/min 4.3 A 2 A 7.2 Fullfilled IEC 60034-12 des. N,H 7.3 Nm 2.8 3.4 2.8 480 r/min Load % Current A Efficiency % Power factor 100 4.3 85.0 / IE2 0.83 75 3.4 85.5 0.78 50 2.6 84.5 0.69 Start 31 0.65 10 s 18 s F/B 40 °C 1000 m.a.s.l. IP55 IC411 self ventilated 6205-2Z/C3 - 6204-2Z/C3 63 0.0027 dB(A) kg-m2 Top CW or CCW 4 18 Remarks: Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC Guaranteed values on request kg kg at load ABB Motors and Generators Load Curves Project Location Department/Author Customer name Customer ref. Item name Our ref. Rev/Changed byDate of issue A 11/04/2011 Saving ident untitled.xls Pages 2(3) 1.00002 Product TEFC, 3-phase, squirrel cage induction motor Type/Frame Product code Rated output PN Type of duty M3AA 90 LB 2 3GAA 091 313-BSE 2.2 kW S1(IEC) 100% Voltage (V) Frequency (Hz) 415 50 Current IN (A) Speed (r/min) 4.3 2890 Power factor at PN 0.83 Efficiency (%) at PN 85 1.4 1.3 1.2 1.1 1 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1 1.1 1.2 P2/Pn Current Efficiency Load characteristics (IEC 60034-2-1:2007) Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC Cosinus 1.3 1.4 ABB Motors and Generators Starting Curves Project Location Department/Author Customer name Customer ref. Our ref. Rev/Changed b Date of issue Saving ident Item name 1.00002 Pages A 11/04/2011 untitled.xls TEFC, 3-phase, squirrel cage induction motor M3AA 90 LB 2 3GAA 091 313-BSE Frequency (Hz) 2.2 kW Rated current IN S1(IEC) 100% Type of product Type/Frame Product code Rated output PN Type of duty Jmotor (kgm2) Jload (kgm2) 0.0027 Voltage (V) 100% Tstart/TN Speed (r/min) TN (Nm) 2890 7.3 3(3) 50 4.3 A Voltage (V) Tstart/TN 415V(100%) 2.8 Tload (Nm) Starting time (s) Speed (r/min) Is/In 7.2 Run-up time (s) Speed (r/min) Is/In 7.2 Nbr. of consecutive starts Tmax/Tn 3.4 Tmax/Tn 3.4 4.5 9 4 8 3.5 7 3 6 2.5 5 2 4 1.5 3 1 2 0.5 1 Is/In Ts/Tn 415 2.8 0 0 250 500 750 0 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 Speed (r/min) TMotorUn 415V TMotorU2 415V(100%) IMotorUn 415V IMotorU2 415V(100%) Load characteristics (IEC 60034-2-1:2007) Data based on situation 13/11/2010 All data subject to tolerances in accordance with IEC