Bussmann Circuit Protection Solutions Surge Protection Made Simple ™ IEC Applications High Performance Lightning & Surge Protection Products for All IEC Applications • Vibration and shock resistant according to EN 60068-2 standards. • easyID™ Visual indication and optional remote contact signaling make status monitoring simple. • High surge discharge capacity due to heavy-duty zinc oxide varistor and spark-gap technology. • Wide range of IEC Class l and Class ll SPD covering all the major markets around the world. • Modular DIN-rail design with color-coding and rejection feature makes it easy to identify, install and maintain. The Need for Surge Protection Today’s world is full of electronic products and devices that are susceptible to damage from overvoltage surges. Whether the cause is static discharge or lightning, overvoltage surges can quickly destroy consumer electronics or sophisticated electronic packages used in industrial and commercial applications. Surge protection products from Bussmann help assure power quality that’s free from damaging surges and overvoltage conditions. Safe and Simple ・IP20 Finger-safe construction. ・Suppressor rejection feature make it easy to know the suppressor system is installed and properly operating to protect your IEC system investment. ・Simple selection of system voltage and remote contact signaling option. ・Five year limited warranty.* Complete Line of Surge Protection Solutions Bussmann offers surge protection products for PV, wind power, telecom and UL, applications. Base & Module Number System BSP X X XXX XXX X BSP = Product Series Technology Type M = MOV H = Hybrid S = Spark-Gap G = GDT Poles 1 = 1-pole 2 = 2-pole 3 = 3-pole 4 = 4-pole System Voltage 230 = 230Vac 320 - 320Vac - Specific to India 400 = 400Vac - Specific to China 440 = 440Vac System Type IT = IT system TN = TN system TNC = TNC system TNS = TNS system TT = TT system Optional Remote Contact Signaling R = Optional contact signaling Blank = No remote switch option Replacement Module Number System BP X XXX BP = Product Series Technology M = MOV S = Spark-Gap XXX H = Hybrid G = GDT MCOV 50NPE*, 100NPE*, 255, 275, 320, 385, 440 *NPE = Neutral to Earth System Type IEC = All IEC System Types PV Wind Telecom UL IEC Ordering Information Power System Poles TN 2 Volts 230 Bussmann Part Number BSPS2255TN(R) Lightning Arrestors - IEC Class l Description 230V Combined lightning current and surge arrestor for 2-pole TN systems (remote) TNC TNS TT 3 4 2 230 230 230 BSPS3255TNC(R) BSPS4255TNS(R) BSPS2255TT(R) TT 4 230 BSPS4255TT(R) TN TN TN TN TN TN TNC TNS TT 1 1 1 1 1 2 3 4 2 230 230 320 400 440 230 230 230 230 BSPM1275TN(R) BSPG1255NPE(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM2275TN(R) BSPM3275TNC(R) BSPM4275TNS(R) BSPH2275TT(R) 230V Combined lightning current and surge arrestor for 3-pole TN-C systems (remote) 230V Combined lightning current and surge arrestor for 4-pole TN-S systems (remote) 230V Combined lightning current and surge arrestor for single-pole 1+1 TT and TN systems (remote) 230/400V Combined lightning current and surge arrestor for 3+1 TT and TN-S systems (remote) Surge Arrestors - IEC Class ll 230V Surge arrestor for single-pole TN systems (remote) 240V 1-Pole GDT DIN rail SPD for N-PE (remote) 320V Surge arrestor for single-pole TN systems (remote) (India Market 230/400V) 400V Surge arrestor for single-pole TN systems (remote) (Chinese Market 230/400) 440V Surge arrestor for single-pole TNC systems (400/690V) (remote) 230V Surge arrestor for 2-pole TN systems (remote) 230/400V Surge arrestor for 3-pole TNC systems (remote) 230/400V Surge arrestor for 3-pole TNS systems (remote) 230V Surge arrestor for 2-pole phase TT systems (remote) TT 4 230 BSPH4275TT(R) 230/400V Surge arrestor for 3+1 TT and TN-S systems (remote) * See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.bussmannasia.com/surge. For more information visit our website at www.bussmannasia.com Modules BPS255IEC, BPS50NPE BPS255IEC BPS255IEC BPS255IEC, BPS50NPE BPS255IEC, BPS100NPE BPM275IEC BPG255NPE BPM320IEC BPM385IEC BPM440IEC BPM275IEC BPM275IEC BPM275IEC BPM275IEC, BPSNPE BPM275IEC, BPSNPE Surge Protection Made Simple ™ for IEC Applications IEC Class I Combined Lightning, Current and Surge Arresters for 230 Volt, 2-Pole TN & TT Systems Description The Bussmann ® IEC Class I 230 Volt, two-pole, modular combined lightning, current and surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPS2255TN(R) BSPS2255TT(R) 230 Volt models are offered with MCOV rating of 255 volts. TN System Arresters The features of these two-pole devices are for use as a modular combined lightning and current arrester and surge arrester for use in single TN- systems (“2-0” circuit). TT System Arrester Provides a current arresting means for use in single TT- systems (“1-1” circuit). Visual Status Indication Remote Signal Contact Available Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Creepage Discharge Spark Gap Dimensions - mm Circuit Diagrams Shown with optional remote contact signaling Spark Gap Trigger BSPS2255TNR BSPS2255TTR Shown with optional remote contact signaling Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com Ordering Information System Voltage/Poles Max. Continuous operating AC voltage (MCOV) [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Modules: MOV technology Spark Gap technology 230V/2 255V BSPS2255TN BSPS2255TNR (2X) BPS255IEC -- 230V/2 255V BSPS2255TT BSPS2255TTR (1X) BPS255IEC (1X) BPS50NPEIEC* Specific energy [L+N-PE] [W/R] Lightning impulse current (10/350 µs) [L, N-PE] [Iimp] 625.00 kJ/ohms 25kA Specific energy [L,N-PE] [W/R] 156.25 kJ/ohms Voltage protection level [L-PE]/[N-PE] [UP] Voltage protection level [L-N]/[N-PE] [UP] Follow current extinguishing capability AC [Ifi] Follow current extinguishing capability [L-N]/[N-PE] [Ifi] Temporary overvoltage (TOV) [N-PE] [UT] SPD according to EN 61643-11/... IEC 61643-1 Energy-coordinated protection effect with regard to the terminal equipment Energy-coordinated protection effect with regard to the terminal equipment (< _ 5m) Nominal AC voltage [UN] Lightning impulse current (10/350 µs) [L+N-PE] [Itotal] Nominal discharge current (8/20 µs) [In] Follow current limitation/Selectivity Response time [tA] Max. Backup fuse (L) up to IK < _ 50kA rms Max. Backup fuse (L) for IK > 50kA rms Max. Backup fuse (L-L´) Temporary overvoltage (TOV) [L-N] [UT] TOV characteristics Operating temperature range (parallel connection) [TUP] Operating temperature range (series connection) [TUS] Operating temperature range [parallel]/[continuity] [TU] Operating state/fault indication Number of ports < _ 1.5 kV/< _ 1.5 kV -50kA rms --- -25/50kA Is [L-N]/[N-PE] 156.25kJ/ohms/ 625.00 kJ/ohms -< _ 1.5kV/< _ 1.5kV -50kA rms/100A rms 1200V/200 ms Specifications Cross-sectional area (L, L´, N, N´, PE, Cross-sectional area (L, N, PE) [max.] Cross-sectional area (L´, N´, For mounting on Enclosure material Location category Degree of protection Capacity Standards Information Product Warranty Type 1/Class I Type 1 + Type 2 Type 1 + Type 2 + Type 3 230V 50kA 25/50kA no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.) < _ 100 ns 315A gL/gG 200A gL/gG 125A gL/gG 440V/5 sec. withstand -40°C to +80°C -40°C to +60°C -40°C to +80°C/-40°C to +60°C green (good)/red (replace) 1 ) [min.] 10mm2 solid/flexible 50mm2/1AWG stranded-35mm2/2AWG flexible ) [max.] 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN Rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 4 mods., DIN 43880 KEMA Five Years** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Recommended Bussmann NH DIN Size Back Up Fuses Size NH Fuse Part Number Size NH Fuse Part Number 00 125NHG00B (max L-L) 02 125NHG02B (max L-L) 0 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA) 01 125NHG01B (max L-L) 2 315NHG2B (max L < _50kA) 1 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L < _ 50kA) Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class I Combined Lightning, Current and Surge Arrester for 230/400 Volt, 3-Pole TNC Systems Description The Bussmann® IEC Class I 230 Volt, three-pole, modular combined lightning, current and surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPS3255TNC(R) 230 Volt models are offered with a MCOV rating of 255 volts. TNC System Arrester The features of these three-pole devices are for use in TN-C 230/400 Volt systems (“3-0” circuit) against surges. Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Remote Signal Contact Available Visual Status Indication Creepage Discharge Spark Gap Circuit Diagrams Dimensions - mm Spark Gap Trigger Shown with optional remote contact signaling BSPS3255TNC(R) Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com Ordering Information System Voltage/Poles Max. Continuous operating AC voltage (MCOV) [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Module MOV technology 230/400V/3 255V BSPS3255TNC BSPS3255TNCR BPS255IEC Specifications SPD according to EN 61643-11/... IEC 61643-1 Energy-coordinated protection effect with regard to the terminal equipment Energy-coordinated protection effect with regard to the terminal equipment (< _ 5m) Nominal AC voltage [UN] Lightning impulse current (10/350 µs) [L1+L2+L3-PEN] [Itotal] Specific energy [L1+L2+L3-PEN] [W/R] Lightning impulse current (10/350 µs) [L-PEN] [Iimp] Specific energy [L-PEN] [W/R] Nominal discharge current (8/20 µs) [In] Voltage protection level [UP] Follow current extinguishing capability AC [Ifi] Follow current limitation/Selectivity Response time [tA] Max. Backup fuse (L) up to IK = 50kA rms Max. Backup fuse (L) for IK > 50kA rms Max. Backup fuse (L-L´) Temporary overvoltage (TOV) [UT] TOV characteristics Operating temperature range [parallel]/[continuity] [TU] Operating state/fault indication Number of ports Type 1/Class I Type 1 + Type 2 Type 1 + Type 2 + Type 3 230/400V 75kA 1.40 MJ/ohms 25kA 156.25kJ/ohms 25/75kA < _ 1.5kV 50kA rms no tripping of a 20A gL/gG fuse up to 50kA rms (prosp.) < _ 100 ns 315A gL/gG 200A gL/gG 125A gL/gG 440V/5 sec. withstand -40°C to +80°C/-40°C to +60°C green (good)/red (replace) 1 Cross-sectional area (L1, L1´, L2, L2´, L3, L3´, PEN, Cross-sectional area (L1, L2, L3, PEN) [max.] 10mm2 solid/flexible 50mm2/1AWG stranded-35mm2/2AWG flexible Cross-sectional area (L1´, L2´, L3´, Mounting Enclosure material Location category Degree of protection Capacity Standards Information Product Warranty ) [min.] ) [max.] 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN rail per to EN 60715 Thermoplastic, UL 94V0 Indoor IP20 6 mods., DIN 43880 KEMA Five Years* Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Size 00 0 01 1 Recommended Bussmann NH DIN Size Back Up Fuses NH Fuse Part Number Size NH Fuse Part Number 125NHG00B (max L-L) 02 125NHG02B (max L-L) 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA) 125NHG01B (max L-L) 2 315NHG2B (max L < _50kA) 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L < _ 50kA) The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class I Combined Lightning, Current and Surge Arresters for 230/400 Volt, 4-Pole TNS & TT Systems Description The Bussmann ® IEC Class I 230 volt, four-pole, modular combined lightning, current and surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPS4255TNS(R) BSPS4255TT(R) 230 Volt models are offered with MCOV ratings of 255 volts. TNS System Arresters The features of these four-pole devices are for use in TNS 230/400 volt systems (“4-0” circuit) against surges. TT System Arrester Provides a current arresting means between neutral conductor and protective conductor in TT 230/400 volt systems (“3+1” circuit) against surges. Visual Status Indication Remote Signaling Contact Remote Signal Contact Available The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Creepage Discharge Spark Gap Dimensions - mm Circuit Diagrams Spark Gap Trigger BSPS4255TNS(R) Shown with optional remote contact signaling Shown with optional remote contact signaling BSPS4255TT(R) Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com Ordering Information System Voltage/Poles Max. Continuous operating AC voltage (MCOV) [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Modules: MOV technology Spark Gap technology 230/400V/4 255V BSPS4255TNS BSPS4255TNSR BPS255IEC -- 230/400V/4 255V BSPS4255TT BSPS4255TTR BPS255IEC BPS100NPEIEC* Specifications SPD according to EN 61643-11/... IEC 61643-1 Energy-coordinated protection effect with regard to the terminal equipment Energy-coordinated protection effect with regard to the terminal equipment (< _ 5m) Nominal AC voltage [UN] Lightning impulse current (10/350 µs) [L1+L2+L3+N-PE] [Itotal] Specific energy [L1+L2+L3+N-PE] [W/R] Lightning impulse current (10/350 µs) [L, N-PE] [Iimp] TNS system specific energy [L,N-PE] [W/R] TT system specific energy [L-N]/[N-PE] [W/R] Nominal discharge current (8/20 µs) [In] Voltage protection level [L-PE]/[N-PE] [UP] TNS system follow current extinguishing capability AC [Ifi] TT system follow current extinguishing capability AC [Ifi] Follow current limitation/Selectivity Response time [tA] Max. Backup fuse (L) up to IK < _ 50kA rms Max. Backup fuse (L) for IK > 50kA rms Max. Backup fuse (L-L´) Temporary overvoltage (TOV) [L-N] [UT] Temporary overvoltage (TOV) [N-PE] [UT] TOV characteristics Operating temperature range [parallel]/[continuity] [TU] Operating state/fault indication Number of ports Cross-sectional area (L1, L1´, L2, L2´, L3, L3´, N, N´, PE, Cross-sectional area (L1, L2, L3, N, PE) [max.] Cross-sectional area (L1´, L2´, L3´, N´, Mounting Enclosure material Location category Degree of protection Capacity Agency Information Product Warranty Type 1/Class I Type 1 + Type 2 Type 1 + Type 2 + Type 3 230/400V 100kA 2.50MJ/ohms 25kA 156.25kJ/ohms 156.25kJ/ohms/2.50kJ/ohms 25/100kA < _ 1.5kV/< _ 1.5kV 50kA rms 50kA rms/100A rms No tripping of a 20A gL/gG fuse up to 50kA rms (prosp.) < _ 100 ns 315A gL/gG 200A gL/gG 125A gL/gG 440V/5 sec. 1200V/200mS Withstand -40°C to +80°C/-40°C to +60°C green (good)/red (replace) 1 ) [min.] ) [max.] 10mm2 solid/flexible 50mm2/1AWG stranded-35mm2/2AWG flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN Rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 8 mods., DIN 43880 KEMA Five Years** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Size 00 0 01 1 Recommended Bussmann NH DIN Size Back Up Fuses NH Fuse Part Number Size NH Fuse Part Number 125NHG00B (max L-L) 02 125NHG02B (max L-L) 125NHG0B (max L-L) 02 200NHG02B (max L Ik >50kA) 125NHG01B (max L-L) 2 315NHG2B (max L < _50kA) 200NHG1B (max L Ik >50kA) 03 315NHG03B (max L < _ 50kA) The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class II Surge Arresters for 230-600 Volt, 1-Pole TN & TT Systems Description The Bussmann IEC Class II 275, 320, 385, 440 and 600 volt, onepole, modular surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPM1275TN(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM1600TN(R) BSPG1255NPE(R) Class II single-pole surge arrester models are offered with MCOV ratings of 255, 275, 320, 385, 440 and 600 volts. TN System Arresters The features of these single-pole devices are for use as a single device or in combination with other devices. TT System Arrester Provides a current arresting means between neutral conductor and protective conductor in TT systems, this device helps ensure fulfilling the requirements for protection of personnel and equipment in “3+1” and “1+1” circuits. Visual Status Indication Remote Signal Contact Available Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Module Circuit Diagrams - Shown with optional remote contact signaling Dimensions - mm MOV Thermal Disconnector Gas Discharge Tube (single) Shown with optional remote contact signaling BSPM1275TN(R) BSPM1320TN(R) BSPM1385TN(R) BSPM1440TN(R) BSPM1600TN(R) BSPG1255NPE(R) For more information visit our website at www.bussmannasia.com Ordering Information System Voltage/Poles 230V/1 Max. Continuous operating AC voltage (MCOV) [UC] 275V Catalog Numbers: Without Remote Signaling BSPM1275TN (Base + Modules) With Remote Signaling BSPM1275TNR Replacement Modules BPM275IEC 230V/1 230V/1 400V/1 600V/1 230V/1* 320V 385V 440V 600V 255V BSPM1320TN BSPM1385TN BSPM1440TN BSPM1600TN BSPG1255NPE BSPM1320TNR BSPM1385TNR BSPM1440TNR BSPM1600TNR BSPG1255NPER BPM320IEC BPM385IEC BPM440IEC BPM600IEC BPG255NPE Specifications Line system type Max. Continuous operating DC voltage [UC] Voltage protection level [UP] Voltage protection level at 5kA [UP] Max. mains-side overcurrent protection Short-circuit withstand capability for max. mains-side overcurrent protection Temporary overvoltage (TOV) [UT] Response time [tA] Follow current extinguishing capability [Ifi] Lightning impulse current (10/350 µs) [Iimp] Nominal discharge current (8/20 µs) [In] Max. Discharge current (8/20 µs) [Imax] Standards Information Capacity SPD according to EN 61643-11 SPD according to IEC 61643-1 TOV characteristics Operating temperature range [TU] Operating state/fault indication Number of ports Cross-sectional area (min.) Cross-sectional area (max.) Mounting Enclosure material Location category Degree of protection Product Warranty TN / TT 350V < _ 1.25kV < _ 1kV 125A gL/gG TN / TT 420V < _ 1.5kV < _ 1.2kV 125A gL/gG TN / TT 500V < _ 1.75kV < _ 1.35kV 125A gL/gG TN 585V < _ 2kV < _ 1.7kV 125A gL/gG TN 600V < _ 2.5kV < _ 2kV 100A gL-gG TT -< _ 1.5kV --- 50kArms 25kArms 25kArms 25kArms 25kA rms -- 335V/5 sec. < _ 25 ns --20kA 40kA KEMA 335V/5 sec. < _ 25 ns --20kA 40kA KEMA, CSA 600V/5 sec. < _ 25 ns --15kA 30kA KEMA 1200V/200 ms < _ 100 ns 100Arms 12kA 20kA 40kA KEMA 385V/5 sec. 580V/5 sec. < _ 25 ns < _ 25 ns ----20kA 20kA 40kA 40kA KEMA, CSA KEMA, CSA 1 mod., DIN 43880 Type 2 Class II Withstand -40°C to +80°C Green (good) / Red (replace) 1 1.5mm2/14AWG solid/flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN Rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 Five Years** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Recommended Bussmann Back Up Fuses DIN TT / TN System NH Fuse Part Numbers Fuse Size 275, 320, 385, 440V 600V 00 125NHG00B 100NHG00B-690 0 125NHG0B 100NHG0B-690 01 125NHG01B -1 -100NHG1B-690 02 125NHG02B -2 -100NHG2B-690 The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class II Surge Arresters for 230 Volt, 2-Pole TN & TT Systems Description The Bussmann ® IEC Class II 230 volt, two-pole, modular surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPM2275TN(R) BSPH2275TT(R) 230 Volt models are offered with MCOV ratings of 255 and 275 volts. TN System Arresters The features of these single-pole devices are for use in single-phase 230 volt TN systems (“2-0” circuit). TT System Arrester The features of these single-pole devices are for use in single-phase 230 volt TT and TNS systems (“1-1” circuit). Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Visual Status Indication Remote Signal Contact Available MOV Thermal Disconnector Circuit Diagrams Dimensions - mm Gas Discharge Tube (single) BSPM2275TN(R) BSPH2275TT(R) Shown with optional remote contact signaling Shown with optional remote contact signaling Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com Ordering Information System Voltage/Poles Max. continuous operating AC voltage (MCOV) [UC] Max. Continuous operating AC voltage (MCOV) [L-N] [UC] Max. Continuous operating AC voltage (MCOV) [N-PE] [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Modules: MOV Technology Spark Gap technology 230V/2 275V --BSPM2275TN BSPM2275TNR BPM275IEC -- 230V/2 -275V 255V BSPH2275TT BSPH2275TTR BPM275IEC BPSNPEIEC* -< _ 1.25kV < _ 1kV ----< _ 25 ns --335V/5 sec. --- 12kA --< _ 1.25kV < _ 1kV < _ 1.5kV 100A rms -< _ 25 ns < _ 100 ns -335V/5 sec. 1200V/200 ms Specifications Lightning impulse current (10/350 µs) [N-PE] [Iimp] Voltage protection level [UP] Voltage protection level at 5kA [UP] Voltage protection level [L-N] [UP] Voltage protection level [L-N] at 5kA [UP] Voltage protection level [N-PE] [UP] Follow current extinguishing capability [N-PE] [Ifi] Response time [tA] Response time [L-N] [tA] Response time [N-PE] [tA] Temporary overvoltage (TOV) [UT] Temporary overvoltage (TOV) [L-N] [UT] Temporary overvoltage (TOV) [N-PE] [UT] SPD according to EN 61643-11 SPD according to IEC 61643-1 Nominal discharge current (8/20 µs) [In] Max. discharge current (8/20 µs) [Imax] Max. mains-side overcurrent protection Short-circuit withstand capability for max. mains-side overcurrent protection Nominal AC voltage [UN] TOV characteristics Operating temperature range [TU] Operating state/fault indication Number of ports Cross-sectional area (min.) Cross-sectional area (max.) Mounting Enclosure material Location category Degree of protection Capacity Standards Information Product Warranty Type 2 Class II 20kA 40kA 125A gL/gG 50kA rms 230V withstand -40°C to +80°C green (good)/red (replace) 1 1.5mm2/14AWG solid/flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 2 mods., DIN 43880 KEMA Five Years** Remote Contact Signaling Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * N-PE Surge arrester for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Recommended Bussmann Back Up Fuses DIN Fuse Size NH Fuse Part Number 00 125NHG00B 0 125NHG0B 01 125NHG01B 02 125NHG02B The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class II Surge Arrester for 120/240 and 230/400 Volt, 3-Pole TNC Systems Description The Bussmann ® IEC Class II 120/240 volt and 230/400 volt, threepole, modular surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPM3150TNC(R) BSPM3275TNC(R) BSPM3385TNC(R) 120 Volt models are offered with a MCOV rating of 150 volts. 230 Volt models are offered with a MCOV rating of 275 or 385 volts. TNC System Arresters The features of these three-pole devices are for use in TN-C 120/240 volt or 230/400 volt systems (“3-0” circuit) against surges. Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Visual Status Indication Remote Signal Contact Available MOV Circuit Diagrams Dimensions - mm Thermal Disconnector BSPM3150TNC(R), BSPM3275TNC(R), BSPM3385TNC(R) Shown with optional remote contact signaling Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com ORDERING INFORMATION System Voltage/Poles Max. Continuous operating AC voltage (MCOV) [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Module MOV technology 120V/3 150V BSPM3150TNC BSPM3150TNCR BPM150IEC 230V/3 275V BSPM3275TNC BSPM3275TNCR BPM275IEC 230V/3 385V BSPM3385TNC BSPM3385TNCR BPM385IEC SPECIFICATIONS Nominal AC voltage [UN] Voltage protection level [UP] Voltage protection level at 5kA [UP] Short-circuit withstand capability for max. mains-side overcurrent protection Temporary overvoltage (TOV) [UT] Standards Information Nominal discharge current (8/20 µs) [In] Max. Discharge current (8/20 µs) [Imax] SPD according to EN 61643-11 SPD according to IEC 61643-1 Response time [tA] Max. mains-side overcurrent protection TOV characteristics Operating temperature range [TU] Operating state/fault indication Number of ports Cross-sectional area (min.) Cross-sectional area (max.) Mounting Enclosure material Location category Degree of protection Capacity Product Warranty 120/240V < _ 0.7kV < _ 0.55kV 50kArms 175V/5 sec -15kA 230/400V 230/400V < _ 1.25kV < _ 1.75kV < _ 1kV < _ 1.35kV 50kArms 25kArms 335V/5 sec. 385V/5 sec KEMA -20kA 20kA 40kA Type 2 Class II < _ 25 ns 125A gL/gG withstand -40°C to +80°C Green (good)/Red (replace) 1 1.5mm2/14AWG solid/flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 3 mods., DIN 43880 Five Years* REMOTE CONTACT SIGNALING Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Recommended Bussmann Back Up Fuses DIN Fuse Size NH Fuse Part Number 00 125NHG00B 0 125NHG0B 01 125NHG01B 02 125NHG02B The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com Surge Protection Made Simple ™ for IEC Applications IEC Class II Surge Arresters for 230/400 Volt, 4-Pole TNS & TT Systems Description The Bussmann ® IEC Class II 230/400 volt, four-pole, modular surge arresters feature local, easy ID™ visual indication and optional remote contact signaling. The unique module locking system fixes the protection module to the base part. Modules can be easily replaced without tools by simply depressing the release buttons. Integrated mechanical coding between the base and protection module ensures against installing an incorrect replacement module. BSPM4275TNS(R) BSPH4275TT(R) BSPH4320TT(R) BSPH4385TT(R) These 230 Volt models are offered with MCOV ratings of 275, 320 or 385 volts. TNS System Arrester The features of these four-pole devices are for use in TNS 230/400 volt systems (“4-0” circuit) against surges. TT System Arrester The features of these four-pole devices are for use in TT and TN-S 230/400 volt systems (“3+1” circuit) against surges. Remote Signaling Contact The three-pole terminal remote signaling contact versions have a floating changeover contact for use as a break or make contact, according to circuit concept. Dimensions - mm Visual Status Indication Remote Signal Contact Available Circuit Diagrams BSPM4275TNS(R) Shown with optional remote contact signaling MOV Thermal Disconnector Gas Discharge Tube (single) BSPH4275TT(R) BSPH4320TT(R) BSPH4385TT(R) Shown with optional remote contact signaling For more information visit our website at www.bussmannasia.com Shown with optional remote contact signaling ORDERING INFORMATION System Voltage/Poles Max. continuous operating AC voltage (MCOV) [UC] Max. continuous operating AC voltage (MCOV) [L-N] [UC] Max. continuous operating AC voltage [N-PE] [UC] Catalog Numbers: Without Remote Signaling With Remote Signaling Replacement Modules: MOV technology Spark Gap technology 230V/4 275V --BSPM4275TNS BSPM4275TNSR BPM275IEC -- 230V/4 230V/4 230V/4 ---275V 320V 385V 255V 255V 255V BSPH4275TT BSPH4320TT BSPH4385TT BSPH4275TTR BSPH4320TTR BSPH4385TTR BPM275IEC BPM320IEC BPM385IEC BPSNPEIEC* BPSNPEIEC* BPSNPEIEC* -< _ 1.25kV < _ 1kV ----< _ 25 ns --335V/5 sec. --- 12kA 12kA 12kA ------< _ 1.25kV < _ 1.5kV < _ 1.75kV < _ 1kV < _ 1.2kV < _ 1.35kV < _ 1.5kV < _ 1.5kV < _ 1.5kV 100Arms 100Arms 100Arms ---< _ 25 ns < _ 25 ns < _ 25 ns < _ 100 ns < _ 100 ns < _ 100 ns ---335V/5 sec. 335V/5 sec. 385V/5 sec. 1200V/200 ms 1200V/200 ms 1200V/200 ms SPECIFICATIONS Lightning impulse current (10/350 µs) [N-PE] [Iimp] Voltage protection level [UP] Voltage protection level at 5kA [UP] Voltage protection level [L-N] [UP] Voltage protection level [L-N] at 5kA [UP] Voltage protection level [N-PE] [UP] Follow current extinguishing capability [N-PE] [Ifi] Response time [tA] Response time [L-N] [tA] Response time [N-PE] [tA] Temporary overvoltage (TOV) [UT] Temporary overvoltage (TOV) [L-N] [UT] Temporary overvoltage (TOV) [N-PE] [UT] Short-circuit withstand capability for max. mains-side overcurrent protection SPD according to EN 61643-11 SPD according to IEC 61643-1 Nominal AC voltage [UN] Nominal discharge current (8/20 µs) [In] Max. discharge current (8/20 µs) [Imax] Max. mains-side overcurrent protection TOV characteristics Operating temperature range [TU] Operating state/fault indication Number of ports Cross-sectional area (min.) Cross-sectional area (max.) Mounting Enclosure material Location category Degree of protection Capacity Standards Information Product Warranty 50kArms 50kArms 25kArms 25kArms Type 2 Class II 230/400V 20kA 40kA 125A gL/gG withstand -40°C to +80°C green (good)/red (replace) 1 1.5mm2/14AWG solid/flexible 35mm2/2AWG stranded-25mm2/4AWG flexible 35mm DIN rail per EN 60715 Thermoplastic, UL 94V0 Indoor IP20 4 mods., DIN 43880 KEMA Five Years** REMOTE CONTACT SIGNALING Remote Contact Signaling Type AC Switching Capacity (Volts/Amps) DC Switching Capacity (Volts/Amps) Conductor Ratings and Cross-Sectional Area for Remote Contact Signal Terminals Ordering Information Changeover Contact 250V/0.1A 250V/0.1A; 125V/0.2A; 75V/0.5A 60/75°C Max. 1.5mm2/14AWG Solid/Flexible Order from Catalog Numbers Above * N-PE Surge arrester module for location between neutral conductor and protective conductor in TT systems. ** See Bussmann SPD Limited Warranty Statement (3A1502) for details at www.cooperbussmann.com/surge. Recommended Bussmann Back Up Fuses DIN Fuse Size NH Fuse Part Number 00 125NHG00B 0 125NHG0B 01 125NHG01B 02 125NHG02B The only controlled copy of this Data Sheet is the electronic read-only version located on the Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. For more information visit our website at www.bussmannasia.com