™ Fuseholders for Indicating Fuses GMT Type Dimensional Data Printed Circuit Board Application Shown With GMT Fuse Installed Note: Similar Body Dimensions of All Holders Are Identical. 0.31" Approx. 0.84" 0.84" (7.7mm) (21.4mm) (21.4mm) 0.64" (16.3mm) 1.02" 0.64" (16.3mm) 0.13" 1.02" HLT (25.9mm) (25.9mm) (3.2mm) 0.15" (3.8mm) HLS 0.15" (3.8mm) HLS-F HLS-C 0.25" (6.4mm) 0.13" (3.2mm) (6.4mm) (10.3mm) 0.84" CATALOG SYMBOL: HLS, HLT, PCT FUSEHOLDERS FOR GMT TYPE INDICATING FUSES ELECTRICAL RATING–60V DC, 125V AC UL RECOGNIZED (GUIDE # IZLT2, FILE E14853) 15AMP (60V DC) Materials: Body: Terminals: HLT-F 0.08" (2.0mm) 0.41" 0.25" HLT-D (21.3mm) Wire Wrap Terminal 0.025" x 0.063" 0.64" (16.3mm) (0.64mm) (1.6mm) 0.45" (11.4mm) 0.11" Fuse Terminal Alarm Terminal PCT-A (2.8mm) PCT Thermosplastic, UL 94V0 flammability rating Tin-plated bifrucated copper For use with GMT Type Indicating Fuses 0.19" (4.8mm) (6.4mm) x "A" Spaces Tolerance to be non-accumulative 0.25" Panel Mounting Data 0.15"(3.8mm) Dia. 0.16"(3.9mm) Dia. .041" Multiple Fuseholders with bus bars Ordering Information–Catalog No. 0.86" (21.8mm) (10.4mm) 1.21" (30.8mm) 0.27" (6.7mm) 0.25" (6.4mm) .09" Dia. Holes (2.4mm) (3 Holes Per Poles of Fuseholder) Termination Location Body Style HLT HLS (No flanges) L (Left only) No. of Poles 01 thru 25 (Min. of 2 poles required for bus bars) Type of bus bars used B1*, B2, B3, B4, B5, SL** (Short Leads .135") ML** (Medium Leads .250") ** Not available with bus bars B1 (Angle Bar Only)* B2 ("L" Bar Only) B3 ("U" Bar Only) * Angle Bar mounts on common or center terminals only. †Minimum of 4 Poles Required. **SL Version is not available with bus bars. Bus Bar Position P1† (Inside– Both Sides) P2 (Outside– Both Sides) B4 (Angle & "L" Bars) R (Right only) P3 (Outside– Right Only) B (Both ends) P4 (Outside– Left Only) B5 ("L" &"U" Bars) The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled.This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0712 BU-SB12567 Page 1 of 1 Data Sheet 5010 Bussmann® Telpower DC Power Distribution Fuses TPA ® 170 Volts, DC, 3–50 Amps Dimensional Data – TPA Fuses 38.10 1.50" 14.61 .58" 4.83 .19" 10.31 .41" CATALOG SYMBOL: TPA and TPA-B DC POWER DISTRIBUTION FUSES AMPERE RATING: 3-50 Amps VOLTAGE RATING: TPA - 170 VOLTS DC; TPA-B - 65V DC INTERRUPTING RATINGS: TPA, 100 kA; TPA-B, 20kA CONSTRUCTION: • SILVER-PLATED BRASS FERRULES AND INDICATOR PIN. • GLASS MELAMINE TUBE. AGENCY APPROVALS: U.L. RECOGNIZED (GUIDE # JFHR2, FILE E56412) CSA CERTIFIED, CLASS 1422-30, FILE 53787 Catalog Numbers TPA-3 TPA-5 TPA-10 TPA-15 TPA-20 TPA-25 TPA-30 TPA-40 TPA-50 TPA-B-20 TPA-B-25 • Recognized branch circuit protection. • Current-limiting capability. • Complete system coordination capability. • Use with Telpower TP15914 and TP15900-4 Disconnect Switches. • Five position spare fuseholder available – Part No. 5TPH. Five Position Spare Fuseholder – 5TPH 75.57 2.98" 26.16 1.03" SPARE FUSE HOLDER BODY DOUBLE SIDED ADHESIVE TAPE 15.88 .63" 12-28-98 SB98107 Rev. A Form No. TPA Page 1 of 2 BIF Doc #5012 Bussmann® Telpower DC Power Distribution Fuses TPA ® 170 Volts DC, 3–50 Amps AMPERE RATING 3 5 1 10 1 10,000 1 CURRENT IN AMPERES 1 .01 1,000 .01 100 .1 10 .1 100 10 10 TIME IN SECONDS TIME IN SECONDS 100 10 15 100 20 30 40 50 CURRENT IN AMPERES TPA-B AMPERE RATING 1,000 20 25 10 1 1,000 100 .01 10 .1 1 TIME IN SECONDS 100 The only controlled copy of this BIF document is the electronic read-only version located on the Bussmann Network Drive. All other copies of this BIF document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 10,000 1,000 TPA 20-50 Amps 1,000 10,000 AMPERE RATING 1,000 TPA 3-15 Amps CURRENT IN AMPERES 12-28-98 SB98107 Rev. A Form No. TPL Page 2 of 2 BIF Doc #5012 Fast-Acting Indicating Telecom Fuse 60Vdc/125Vac Dimensional Data — in 0.127 CONTACT AND ALARM SPRING 0.107 0.688 MAX. 0.585 0.118 Catalog Symbol: GMT Fast-acting indicating fuse for telecom circuits. Ratings: Volts: 60Vdc/125Vac Amps: 18/100 – 15A IR: 450A @ 60Vdc 300A @ 125Vac Agency Information: UL Recognized, Guide JFHR2, File E56412 Materials: Body: Thermoplastic (flammability rating: UL94V0) Terminals: Tin-plated beryllium copper Carton Quantity & Weight: 100 fuses per carton, 0.33 lbs. (150g.) Fuse Holders: Catalog Nos. HLS, HLT and PCT 0.81 Covers — in (mm) 0.20" (5.1mm) BUSS GMT-X 0.95" (24.0mm) 0.36" (9.0mm) 0.84" (21.3mm) GMT-X Fuse Cover General Information: • For telecom, computer, or control circuits. • Visual spring indicating and alarm circuit indicating. • Color coded flags designate amp rating. • Fuses easily replaced without use of insulated tools. • Fuses can be removed with wire hook when mounted on minimum centers. • GMT-X fuse cover available. • GMT-Y fuse cover (with pull-tab) available. 0.95" (24.0mm) 0.20" (5.1mm) BUSS GMT-Y 0.7" (17.8mm) Catalog Symbol and Color Codes Catalog Symbol Color Code Catalog Symbol Color Code GMT-18/100A Yellow GMT-3 1/2A White/Blue GMT-1/4A Violet GMT-4A White/Brown GMT-3/8A White/Gray GMT-5A Green GMT-1/2A Red GMT-7 1/2A Black/White GMT-65/100A Black GMT-10A Red/White GMT-3/4A Brown GMT-12A Yellow/Green GMT-1A Gray GMT-15A Red/Blue GMT-1 1/3A White GMT-Dummy Gray GMT-1 1/2A White/Yellow GMT-A (alarm)* Yellow GMT-2A Orange GMT-X (cover) Clear GMT-3A Blue 0.84" (21.3mm) GMT-Y Fuse Cover *Designed specifically for use in the Telpower® Series 15800 fused disconnect switch. 0708 BU-SB08204 Page 1 of 2 Data Sheet 5008 Amp Rating 1 300 1 18 ⁄100A ⁄4A 3 ⁄8A 65 ⁄100A 1A 1.5A 2A 3A 4A 5A 7.5A 10A 15A 3 ⁄2A ⁄4A 11⁄3A 12A Time-Current Characteristic Curves–Average Melt 100 Time In Seconds 10 1 1,0000 100 10 .01 .11 1 .11 Current In Amps Test Specifications Percent Overload Opening Time 100% 10 min. (minimum) 150% 5 min. (maximum) The only controlled copy of this Data Sheet is the electronic read-only version located on the Cooper Bussmann Network Drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Cooper Bussmann reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Cooper Bussmann also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. 0708 BU-SB08204 Page 2 of 2 Data Sheet 5008