ACIE www.acie-securite.com

advertisement
®
ACIE
CATALOGUE EDITION
www.acie-securite.com
THE ACCESS CONTROL SOLUTION
21
LIST OF THE PRODUCTS
ITEM
2211** serial
AC serial
AC-B120
AC-CCP-* serial
ACFP640
AC-R70**-EV serial
AC-RADA-** serial
ADIP
AT868
AT8WAY
BA403 * serial
BIOMAT-** serial
BM405 * serial
BODER * serial
BOPO * serial
CA301 * serial
CA868 * serial
CCP05 * serial
CL-** serial
CONVERT24-12 38
CP100
CPA
CP-ELA
DCW2R
EVOLUTION * serial
FLEX-M
GA série
INTERMAT-PRO
IO8-ELA
IO8-RAD
LAT
LAT-M
LE-** serial
LEC**ELA serial
LEC**-WDT serial
ITEM
LEC**-WDT serial
LECTEUR-ISO-WDT
LOPM
LOGEV1
LP868-AT
LP868-AT
LP868WDT-AT
MEM01
PAC** serial
PCROLL-** serial
PM485-ELA
* PROX-ELA serial
PO401
PROBUS
PROTEC-POWER
R20 * serial
RT868
RT868
RT868-WDT
RX-MIFARE
RX-MIFARE-WDT
SEPRO
SU * serial
SU485-ELA
SUN * serial
SUN-S-ELA
SUN-S-WDT
SUPM * serial
T868 * serial
TALOS2 ** serial
TALOS-EAB
TALOS-SAB
TRANS-SMS
VIGIK ** serial
WIN-RAD
PAGE
42
44
50
38
45
13
57
22
48
48
32
20
33
49
40
32
33
36
24
38
22
22
8
48
7
50
44
13
13
56
28
29
14
11
18
LISTE
PRODUITS
2
PAGE
18
19
28
6
12
30
19
49
36
15
10
11
50
14
8
33
12
29
19
9
18
49
25
10
26
9
18
27
33
25
53
53
48
52
56
CONTENTS
EVOLUTION
SYSTEM
5
WIEGAND &
DATACLOCK
READERS
STANDALONE
CENTRAL UNITS
POWER SUPPLIES &
VOLTAGE
CONVERTERS
35
17
PUSHBUTTONS &
UNLOCKING CASES
39
21
LOCKINGS &
ARTICULATED ARMS
43
STANDALONE
READERS AND RELAYS
OUTPUTS
23
ACCESSORIES
47
IDS TAGS &
REMOTE
CONTROLS
31
VIGIK SYSTEM
51
WIRELESS CCTV
SECURITY SYSTEM
3
55
ACIE
AVAILABLE NOW
APPLICATION
EVOLUTION SYSTEM
FOR THE EVOLUTION SYSTEM
The EVOLUTION System can communicate with an alarm
system, partially or totally and supervise trought video.
Thus,the access control will be able to manage the
armement and disarmement functions from 16 alarm
partitions.
The alarm central will be able to activate and disactivate up
to 16 accesses profiles
Manage your accesses,
Look at your history,
Unlock the antipassback
Have a simple access to the
everyday utilisation of your
EVOLUTION access control system.
Compatible with the Z6GE
unit centrals
THIS APPLICATION IS FREE
APPLI
4
5
ACIE
EVOLUTION SYSTEM
TECHNICAL FEATURES
TECHNICAL FEATURES
EVOLUTION SYSTEM
POWER-EVOLUTION Unit central
EVOLUTION UNIT CENTRAL WITH POWER-SUPPLY
Self protected box with opening by micro swift.
Dimensions : 400 x 290 x 90 mm
Installation environnement : IP 54 from 0° to 50°C.
Power supply : 220V CA
Loader : 12V CC 2A
Battery 12V 7AH not included
•3000 users
• 600 visitors profiles
•128 access profiles
•30 time schedules
•2 dayly segments by planning
•24 public holidays
•4 periods of holidays
•4 zones of anti-passback
•4 counter areas
•4 zones of outfeed
•128 lift's levels
•16 Intrusion servo-controls
•Non volatile memory non volatile
• IP natif
•Degrated mode management
•IP video flows management
•4 levels of access:
- Conditioned hour control
- Permanent control
- Forbidden access
• SAS management.
- Logic relationships creation
- Supervision module
Software LOGEV1
Global management of 30 doors
interfaces. Programmable by frontal
keypad or software on line USB or
TCP/IP. 16 Unit centrals can be
connected together ie 480 doors.
•Advanced access control
•Lift management
•Video management
•Intrusion servo-controls
FREE ANDROID
APPLICATION
CT-EVOLUTION UNIT
CENTRAL
Compatible Windows
XP – VISTA – SEVEN –
HUIT 32 and 64 Bits
Global control of 100 aereas
Up to 16 control panels by area
Single station installation.
-Advanced control of access
- Lift control
- Video control
- Intrusion servo-control
- Management of parkings with license plate
- ANDROID application for lite management
ACIE
6
EVOLUTION CENTRAL UNIT WITHOUT POWER SUPPLY
Self protected box with opening by micro swift
Dimensions : 175x200x40m
Installation environment: IP 54 from 0° to 50°C.
power supply : 12/24V CA or CC 200mA
7
ACIE
EVOLUTION SYSTEM
TECHNICAL FEATURES
LECTEURS RS485 ELA
EVOLUTION SYSTEM
TECHNICAL FEATURES
système EVOLUTION
Antivandal keypad RS485-ELA SUN-S-ELA
Local unit PROTEC-POWER
LOCAL UNIT EVOLUTION WITH POWER SUPPLY
KEYPAD FOR ELA EVOLUTION BUS
Self protected box with opening by micro swift.
Dimensions keypad : 110x85x22mm
Dimensions 345 x 245 x 80 mm
Electronic : 110x110x80mm
Installation environment: IP 54 from 0° to 50°C.
Installation environment : Keypad
Power supply :220V CA
IP66 - 30° to 50°C Electronic : IP54 0°
Loader 12V CC 1.5A
à 50°C
Battery 12V 7AH not included
Power supply : 12V CC 160mA
Access level : code from 1 to 8 digits
Global control of the door for one reader *
or two with Wiegand or Dataclock.
3 Inputs,door supervision,exit request and
inhibition.
2 Relays ,door driver and available,programmable.
Trigger action or maintained
*
2 readers in parallel if no zone option is programmed
in the interface
Global control of the door for one
reader or two with Wiegand format or
DataClock.
3 Inputs, door supervision,exit request
and inhition.
2 relays, door driver and available ,
programmable. Trigger action or
maintained.
Keypad + proximity RS485-ELA
Local unit CP-ELA
RX-MIFARE
roximit
LOCAL UNIT EVOLUTION WITHOUT POWER SUPPLY
Self protected box with opening by micro swift.
Dimensions : 158x 87x33mm
Installation environment : IP40 - 20° to 50°C
Power supply : 12/24V CC 100mA
Dimensions 110x110x48m
Installation environment : IP 54 from 0° to 50°C.
Frequency of emission : 13.56MHz format MIFARE
Read/Write
Power supply 12/24V CA or CC 100mA
Access level :
- tag only
- code only
- tag confirmed by code
ACIE
8
9
ACIE
EVOLUTION SYSTEM
TECHNICAL FEATURES
Keypad RS485-ELA SU485-ELA
EVOLUTION SYSTEM
TECHNICAL FEATURES
Proximity RS485-ELA Serial LEC**-ELA
PROXIMITY FOR ELA EVOLUTION BUS
KEYPAD RS485-ELA FOR EVOLUTION SYSTEM
Reader dimensions : 120x50x22mm
Dimensions : 105x85x40mm
Installation environment : IP65 - 30° to 50°C
Electronic : 110x110x80mm
Reader installation environment : IP60 -
Power supply : 12/24V CC 50 to 200mA
30° to 50°C
Outputs for inverter and timer relays from «1 to 99 ‘’ or
Electronic : IP54 0° to 50°
maintainted
Power supply : 12V CC 160mA
Users codes from 1 to 8 digits
Ref. SAB : Suplement for INOX surface mounting
Ref. EAB : Suplement for INOX inbuilt mounting.
Ref. LECEM-ELA 125KHz format EM
Ref. LECMI-ELA 13.56MHz format MIFARE
Global control of the door for one reader *
or two in format Wiegand 26 or DataClock.
3 Inputs, supervision of the door, exit
request, and inhibition.
2 Relays, door driver and available ,
programmable trigger action or maintained
Global control of the door for one reader *
or two in format Wiegand 26 or DataClock.
3 Inputs, supervision of the door, exit
request, and inhibition.
2 Relays, door driver and available ,
programmable trigger action or maintained
*2 readers in parallel if no zone option is programmed
in the interface
* 2 readers in parallel if no zone option is programmed
in the interface
Proximity RS485-ELA *PROX-ELA
Proximity RS485-ELA PM485-ELA
PROXIMITY FOR ELA EVOLUTION BUS
Reader dimensions : 115x50x22mm
READER RS485-ELA FOR EVOLUTION SYSTEM
Electronic : 110x110x80mm
Dimensions : 110 x 85 x 40 mm
Installation environment IP 65 de -30° à 50°C.
Reader Installation environment : IP60
- 30° to 50°C
Power supply 12v CC/CA 40 to 100mA
Electronic : IP54 0° to 50°
2 Outputs for inverter and timer relays from «1 to 99 ‘’ or
Power supply : 12V CC 160mA
maintainted
Frequency of emission 125KHz format EM
Ref. PPROX-ELA 125KHz polycarbonate box
Ref. TPROX-ELA 125KHz Zamac box
Ref. PMR-SAB : Suplement for INOX surface mounting
Ref. PMR-EAB : Suplement for INOX inbuilt mounting.
ACIE
EVOLUTION
SYSTEM
10
EVOLUTION
SYSTEM
11
ACIE
EVOLUTION SYSTEM
TECHNICAL FEATURES
Radio RS485-ELA RT868
EVOLUTION SYSTEM
TECHNICAL FEATURES
Plate Reader RS485-ELA INTERMAT-PRO
CONTROL TOTEM
RADIO FOR ELA EVOLUTION BUS
Dimensions : 150x 160x40mm
Installation environment: IP54 - 30° to 50°C
Power supply : 12/24V CC 80 to 200mA
Frequency of emission : 868MHz rolling code
Antena ¼ wired wave
An optional antena Ref.AT868 can be added for the
obstacles crossing
3,5 m
3,5 m
Automatisme
INTERMAT-PRO
Détection de véhicule
ELA interface for the control of number plate
The plates are liken to to tags
Dimensions : 1005 x 270 x 275 mm
Inox IP65
Power supply : 230v CA
Direct connection on the ELA-EVOLUTION bus
Reading up to 7 m night and day
Compatible with the LOG-EV1 version 10.31
Extension inputs-outputs IO8-ELA+
Self protected box with opening by micro swift.
Dimensions : 194x135x75m
Installation environment : IP54 - 30° to 50°C Power
supply : 12/24V CA or CC 100mA
8 inputs contacts and 8 programable relays outputs
Global control of the door.
3 Inputs, door supervision, exit
request,and inhibition. 2 Relays,
door driver and available ,
programmable. Trigger action or
maintained
The outputs relations of the
programmable inputs can be done
on distants relays on the bus.
The relays can be controlled by programmable
inputs, time solts, acess profiles.
Free-hand VL RS485-ELA LP868-AT
Serial AC-R70-**EV Video Storage
EXPLOITATION OF THE ACCESS CONTROL
EVENTS ON RECORDED INDEX POST AND
EVENTS
FREE HAND FOR ELA EVOLUTION BUS
Dimensions : 150x 160x40mm
Installation environment : IP54 - 30° to 50°C
Power supply: 12/24V CC 80 to 200mA
Pop-up of images in real time on access control events
AC-R7040-EV for 4 ACVISION cameras
AC-R7080-EV for 8 ACVISION cameras
AC-R7016-EV for 16 ACVISION cameras
AC-R7032-EV for 32 ACVISION cameras
PHOTO
An optional antena Ref.AT8WAY can be added for the
two-way circulation management.
Compatible with almost of the DAhUA, hIKVISION
AC-VISION ET PANASONIC (contact us for the references)
Configuration and exploitation integrated Freeware for
events management on Emap
2 x hard disks with 2TO of storage not included.
12
13
ACIE
EVOLUTION SYSTEM
TECHNICAL FEATURES
PROBUS bus extension
EVOLUTION SYSTEM
TECHNICAL FEATURES
USB registering readerPCROLL** range
Ref. PCROLL-MIEM : Emulation of the tags’ UID 125KHz and 13.56MHz
Ref. PCROLL-MI : Emulation of the tags’ UID 13.56MHz
Ref. PCROLL-EM : Emulation of the tags’ UID 125KHz
Self protected box with opening by micro swift.
Dimensions : 110X110X48mm
Installation environment : IP40 from 0° to 50°C.
Power supply : 12/24V CA or CC 40mA
Allow the creation of a ELA+ bus new branch .
Power supply provided by the USB port of the computer.
2 PROBUS interfaces can be inserted in
USB interface for the PCROLL
registering reader
the main bus of the central unit
without changing the original capacity
of the 31 interfaces . Each secondary bus
reaches a lenght of 1000m .No adressing is
Internal recorder readerLE-EM
necessary.
pour
Registering of the tags by presentation
Installation environment : 0° to 50°C.
Power supply provided by the unit
Frequency of emission:125KHz format EM
EMULATOR INTERFACE FOR TAGS' UID
Power supply provided by the USB port of the
computer.
Compatible for Wiegand, DataClock reader.
Screw connector for reader with 12V 100mA max.
If the reader’s consumption exceeds
100mA,it would have to be supplied
by
an
external
voltage
source.
Internal recorder reader LE-MI
USB interface for the PCROLL+CÂBLE registering reader
centrale
EMULATOR INTERFACE FOR UID TAGS
MIFARE format reading is
configurable
(standard or inverted)
Wiegand or DataColck configurable
reader.
Light and sound warning activity
ACIE
Registering of the tags by presentation
Installation environment : 0° to 50°C.
Power supply provided by the unit
Frequency of emission:: 13.56MHz format
MIFARE
14
Power supply provided by the USB port of the
computer.
Compatible for Wiegand, DataClock reader.
50 cm cable for 12V 100mA reader max
15
ACIE
EW
N
ADIP
ACCESSES POINTS contrOLLER
®
ACIE
WIEGAND &
DATACLOCK READERS
The Wiegand & Dataclock readers can be integrated in
almost all the door controllers which are on the market
No decision data is integrated in the reader . The
ADIP,the accesses points controller (UTL) enables the conection
of 2 WIEGAND or CLOCK&DATA readers to the IP computing
network. Standalone for one door (in/out).
Wiegand & Dataclock formats of communication comply
with standards of communication protocols.
A Wiegand reader have terminals registered D0(data0)
and D1(data1)
A Dataclock reader have terminals registered D(data) and
The configuration and
consulting only on
computer or
SMARTPHONE application.
C(clock)
The readers are configurables either with micro-switch or
ACIE
with programming process.
The Wiegand readers can be away from 50 m to the
door controller which manages the Dataclock readers
which are situated to 15m.
Outdoor power supply 12vDC and POE for the IP connection
2 IP connections, RJ45 type for interconnecting a second ADIP controler, a
camera or a intercom
2 inputs for WIEGAND or CLOCK&DATA reader
2 programmable inputs for G door detection
2 programmable inputs for push buttons
2 programmable inhibition inputs (INH) (I-SAS)
2 output relays for door control
2 programmable auxiliary relays
Interconnection of 2 devices for security door management
Integrated DynDns in the Webserver device
Peer to peer communication
From 16 to 32 ADIP connectable controlers in network
65 000 users / 16 users groups with bank holidays
Selectable ANTIPSSBACK trought 3 nivels
16 schedules with 2 combinable time slots
Supervision of the entrances and exits from the soft
- Entrance event :
PB Opening door push button
Burglary detection or opened door too long
Start entrance
Antipassback
Entrance with counting
Entrance with counting in relation with the start entrance
- Exit event
Door opening through push button
Burglary alarm (timed)
Maximum opening time alarm (timed) /Detection alamr with RAZ of the
start entrance
Exit relation of user / Exit relation of entrance
Antipassback refusal
Empty area/ full area
General listing of the movement by date, users etc …
www.acie-securite.com
ADIP
16
The Wiegand or DataClock frames can be conveyed
through wires or radio waves which can be very useful for
example assembly point reader or for avoiding civil
engineering works to go from one point to another
You have to use the WIN-RAD radio bridge
e
Page 22
17
ACIE
CARACTERISTIQUES TECHNIQUES
WIEGAND &
DATACLOCK
READERS
TECHNICAL FEATURES
Proximity Wiegand & Dataclock Serial LEC**-WDT
WIEGAND &
DATACLOCK READERS
TECHNICAL FEATURES
lecteur READER
Polycarbonate housing
Dimensions : 112x 42x36mm
Built-in electronics
Light and sound indicators
Green led and buzzer
Installation environment: IP54 - 25° to 65°C
Power : 12V CC 20mA
Dataclock communication.
Cable output of 2.50m
Built-in electronics in polycarbonate housing 120x50x22mm
Light leds and bip.
Green and red leds available
Installation Environement : IP60 - 30° to 50°C
Power : 12V CC 60mA
Ref. LECEM-WDT 125KHz EM format
Ref. LECMI-WDT 13.56MHz MIFARE format
Ref. LECMIEM-WDT 125KHz EM format and 13.56MHz MIFARE
format
The scrolling Dataclock ISO-DT reads
the magnetic track ISO2 of the bank
cards cartes d’abonnement, etc…
The output format of the WDT
readers Is programmable. 6 different
formats are configurable..
Radio Wiegand & dataclock RT868 -WDT
Keypad + proximity Wiegand & Dataclock
RX-MIFARE-WDT
Polycarbonate housing
Dimensions : 158x 87x33mm
Light and sound indicators
Red and green leds available.
Control of the code :
3 nivels of access
- Only tag
- Only code
- Tag confirmed by code
Installation: environment IP40 - 20° to 50°C
Power : 12/24V CC 100mA
Emission frequency: 13.56MHz MIFARE format
Reading/Writing
Wiegand and Dataclock programmable
communication
The RT and LP readers are also
available in 2.45GHz. frequency
Wiegand & Dataclock keypad SUN-S-WDT
Anti-vandal box : 110x 85x22mm
Electronique encapsulée et moulée
Light and sound indicators
Red and green leds available.
Control of the code
Installation: environment IP66 - 30° à 50°C
Power : 12/24V CC 50mA
Wiegand and Dataclock programmable communication
Codes de 1 to 8 digits
ACIE
Polycarbonate housing: 150x 160 x 40 mm
Light and sound indicators
Control of the code
Reading/writing of the remote controls
Antenna 1/4 wired wave
Installation environment: IP54 -30° to 50°C
Power : 12/24V CC 80 to 200mA
Emission frequency: 868MHz rolling code
Wiegand & Dataclock programmable communication
An optional antenna Ref. AT868 can be added for the
radio abstacles crossing.
18
Free hand VL Wiegand & Dataclock
LP868WDT-AT
Polycarbonate housing : 150 x 160 x 40mm
Light and sound indicators of activity
Control of the site’s code
Read/Write of the active tags
Provided with its antenna,90° tube and fixing stapes.
Installation environment : IP54 -30° to 50°C
Power supply : 12/24V CC 80 à 200mA
Wiegand and Dataclock programmable
communication
An optional antenna Ref. AT8WAY can be added for the
two ways flow
19
ACIE
WIEGAND &
DATACLOCK READERS
TECHNICAL FEATURES
Tag+fingerprint or Code+fingerprint BIOMAT-EM
Polycarbonate housing, surface assembly
Dimensions: 195x90x55mm
Installation environment : IP65 -30 to 65C°
Power supply12/24V 40 à 200mA
Provided with power supply 220V/12V500mA
CCP05 Tag reader 125KHz
• Standalone Mode
- 800 users
- 2 outputs relays NO.C.NC.
•System Mode
- Wiegand format Wiegand management
•ELA Mode
- 3000 users
- 2 output relays NO.C.NC.
STANDALONE
CENTRAL UNIT
The access screening of a door is managed only by a
standalone reader.
The access level provided by this kind of reader is
extremly wide
A more advanced level access management is often
necessary .
Thus an access level will be conditionned by one or several
Tag+Fingerprint BIOMAT-MIFARE
schedules, bank holidays, conditions of access direction , a
limited number of accesses, etc.
The standalone central units have their own programming
Polycarbonate housing, surface assembly
Dimensions: 195x90x55mm
Installation environment : IP65 -30 to 65C°
Power supply12/24V 40 à 200mA
Provided with power supply 220V/12V500mA
CCP05 Tag reader 13.56MHz
interface. No software is necessary. Some standalone central
•Standalone mode
- 800 users
- 2 outputs relays NO.C.NC.
•System mode
Management of the Wiegand and Dataclock formats
• ELA Mode
- 3000 users
- 2 outputs relays NO.C.NC
extension more than 2 controlled doors in entrance only or
ACIE
units have essential functions for access management
whereas others are more advanced and offer historical
data,options and so on...
In anycase, a standalone central unit doesn't enable an
one door in entrance and exit.
READERS
WIEGAND
& DATACLOCK
20
STANDALONE
21
ACIE
STANDALONE
CENTRAL UNITS
TECHNICAL FEATURES
STANDALONE READERS
with RELAY OUTPUTS
Central unit CPA
Polycarbonate housing, surface assembly
Dimensions: 105x85x40mm
Installation environment : IP65 -30 to 65C°
Power supply 12V 100mA
The readers with standalone technology, ie without any
communication with a remote element, take their decision
internally.
- Control of one Wiegand format reader - 500 users
- 2 outputs relays NO.C.NC.
The standalone readers have a programming interface,
keypad or micro-switch, and an internal memory for users
storage.
Central unit CP100
The number of users that can be created is from 27 to 800 for
Polycarbonate housing, surface assembly
Dimensions: 175x200x40mm
Installation environment : IP54 de 0 to 50C°
Power supply 12/24V 200mA
the highest capacity of memory.
Some readers have advanced functions, such as the
activation of an access group, the subjection to an alarm
- Control of 2 Wiegand or dataclock formats readers 250 users
- 3 outputs relays NO.C.NC.
- 8 access groups
- 8 time slots
- SAS management
- Counter area
- 1000 recorded events
system, the supervision of the tags batteries or of the remote
controls.
In the case of complicated or expensive civil engineering
works, the standalone readers can be connected to radio
Standalone central unit ADIP
bridges like IO8-RAD.Thus up to 8 relays informations and 8
inputs informations can be relayed.
Power 12 VDC and POE
Consumption 150mA
Dimensions with box 150 x 160 x 40mm
Installation environment IP54 from 0 to 50°C
Web Server integrated
Management of 32 ADIP in network
Management of 2 Wiegand readers
For 1 or 2 doors
65000 Users
2 doors relays and 2 programmable relays
ACIE
22
23
ACIE
CARACTERISTIQUES TECHNIQUES
STANDALONE READERS
WITH RELAY OUTPUTS
TECHNICAL FEATURES
STANDALONE
READERS WITH RELAY
OUTPUTS
TECHNICAL FEATURES
Standalone keypad 2 relays TALOS-2G
STANDALONE relay CL-3C
Ref. TALOS2-G : Polycarbonate - Surface mounting
Ref. TALOS2-S : idem TALOS2-G but in metallic box
Ref. TALOS2-S -TME : idem TALOS2-S but metallic keys
Ref. TALOS-E : accessory for built in assembly
Dimensions : 110x 85x30mm
Installation environment : IP65 - 30° to 50°C
Power : 12/24V CC 25 à 100mA
2 relays ouputs timer relays from «1 to 99 ‘’ or
continuous
60 users codes from 1 to 8 digits
Enlightened keys
Surface mounting box in zamac
Dimensions : 116x 87x38mm
Installation environment : IP65 - 30° to 50°C
Power : 12/24V CC 50 to 200mA
2 inverser time relays outputs from «1 to 99 ‘’ or continuous 60
users codes from 1 to 8 digits
Enlightened keys
Same programmation and
functionning than the SU
family.
Keypad + Standalone free-hands 2 relays keypads
CL-RF
Dimensions : 110x 85x30mm
Installation environment: IP65 - 30° to 50°C
Power : 12/24V CC 25 to 100mA
2 relays ouputs timer relays from «1 to 99 ‘’ or
continuous
60 users codes from 1 to 8 digits
Enlightened keys
Surface mounting box in zamac
Radio receiver for 125KHz tags
Ref. BA-CL : Tag for CL-RF keypads (see product
details page 32)
PHOTO
+ CARACTERISTIQUES
TECHNIQUES
BA-CL
ACIE
24
Standalone keypad 1 - 2 - 4 relays
SU serial
Ref. SU1 : Polycarbonate - Surface mounting 1 relay 60 codes
Ref. SU2 : idem SU1 but 2 relays and enlightened keys
Réf. SU4 : idem SU2 but 4 relays 28 codes
Ref. TME : Supplement for enlightened metallic keys
Ref. SAB : Supplement for surface mounting INOX
Ref. EAB : Supplement INOX built-in front.
Dimensions : 105x85x40mm
Installation environment: IP65 - 30° to 50°C
Power : 12/24V CC 50 to 200mA
inverser time relays outputs from «1 to 99 ‘’ or continuous
Users codes from 1 to 8 digits
Build your SU keypad according
to your needs
25
ACIE
CARACTERISTIQUES TECHNIQUES
STANDALONE
READERS WITH
RELAY OUTPUTS
TECHNICAL FEATURES
Standalone keypad 2 remote relays SUN-S
STANDALONE
READERS WITH
RELAY OUTPUTS
TECHNICAL FEATURES
Keypad + standalone proximity 2 relays
RX-MIFARE
Polycarbonate housing 158x 87x33mm
Light and sound indicators of activity
Green led and red led available
3 access levels:
- Tag only
- Code only
- Tag confirmed by code.
Compatible bus ELA
Installation environment : IP40 - 20° to 50°C
Power supply : 12/24V CC 100mA
Frequency of emission: 13.56MHz format MIFARE
Read/Write
2 reverser and time-lag relays outputs from «1 to 240» or
continuous
800 codes or tags
2 reverser and time-lag relays outputs from «1 to 99» or
maintained
250 users codes 1-8 digits
Enlightened retro keys
Possibility to cable a second keypad as SUN-S-WDT
on the remote electronics.
Remote electronic : 60x150x60mm
keypad : 110x85x22mm
Installation environment : IP66 - 30° to 50°C
Power supply: 12/24V CC 35 to 100mA
Standalone keypad 2 remote relays SUN-P
Piezzo keys
2 reverser and time-lag relays outputs from «1 to 99» or
maintained
250 users codes from 1 to 8 digits
Keypad output on 1.80m cable which can be extended to 15m
Keypad : 155x44x12mm
Remote electronic : 160x150x60mm
Installation environment : IP65 - 30° to 50°C
Power supply : 12V CC 35 to 100mA
Keypad+ standalone proximity 2 relays SUPM Range
Ref. SUPM01: with proximity antenna integrated
Ref. SUPM : with remote proximity antenna
Ref. SUPMLED : same as SUPM but with 2 leds on remote antenna
Ref. SU-SAB : Suplement for INOX front ( only for SUPM and
SUPMLED)
Ref. SU-EAB : Suplement for built-in INOX front
Dimensions : 110x85x40mm
Installation environment : IP65 - 30° to 50°C
Power supply : 12V CC/CA 40 to 100mA
2 reverser and time-lag relays outputs from «1 to 99» or
maintained
250 tags format 125KHz
ACIE
STANDALONE
READERS
RELAY OUTPUTS
26
STANDALONE
READERS
RELAY OUTPUTS
27
ACIE
CARACTERISTIQUES TECHNIQUES
STANDALONE
READERS WITH
RELAY OUTPUTS
TECHNICAL FEATURES
TECHNICAL FEATURES
STANDALONE
READERS WITH
RELAY OUTPUTS
Standalone proximity 2 relays LOPM
Standalone proximity 1 relay LAT-M
RELAY OUTPUTS
Dimensions : 110x85x40mm
Installation environment: IP66- 30° to 50°C
Power : 12V CC 80mA
1 reverser and time-lag relays outputs from «1 to 99» or maintained
30 tags 125KHz format
Green led available
Zamac protection shell
Réf. PMR-SAB : Suplement for INOX front
Réf. PMR-EAB : Suplement for built-in INOX front
Programming cards required:
Réf. CME : Erasing card
Réf. CMP1 : Assignement of the relay1
Réf. CMP2 : Assignement of the relay2
Dimensions : 110x85x40mm
Installation environment : IP65 - 30°to 50°C
Power supply : 12V CC/CA 40 to 100mA
2 reverser and time-lag relays outputs from «1 to 99» or
maintained
250 tags format 125KHz
Standalone proximity 1 relay LAT
Dimensions : 110x85x40mm
Installation environment : IP66- 30° to 50°C
Power supply: 12V CC 80mA
2 reverser and time-lag relays outputs from «1 to 99» or
maintained
30 tags 125KHz format
Green led available
Standalone radio 4 relays RT868
Installation environment : IP54 - 30° to 50°C
Power supply : 12/24V CC 80 to 200mA
Frequency of emission: 868MHz rolling code.
4 reverser and time-lag relays outputs from «1 to 240»
or maintained
800 remote controls
Polycarbonate housing: 150x 160x40mm
Light and sound indicators of activity
Control of the site’s code
Read/Write of remote controls.
Antenna with 1/4 wired wave
Compatible bus ELA
An optional antenna Ref.AT868 can be added for the radio
obstacles crossing
It requires the programming cards:
Ref. CME for the erasing
Ref. CMP1 for the relay 1 assignement
ACIE
28
29
ACIE
STANDALONE
READERS WITH
RELAY OUTPUTS
TECHNICAL FEATURES
IDS TAGS
& REMOTE CONTROLS
Standalone free hand 4 relays LP868-AT
An identifier is a series of numbers (decimal) or numbers
Polycarbonate housing: 150x 160x40mm
Light and sound indicators of activity
and letters ( hexadecimal) memorized in a tag or a remote
control
Control of the site’s code
Read/Write of active tags
Provided with its antenna,90° tube and fixing stapes.
A secret pin is also an identifier when it is tabulated on
Compatible bus ELA
keypad.
Installation environment : IP54 - 30° to 50°C
Power supply: 12/24V CC 80 to 200mA
Frequency of emission: 868MHz rolling code
4 reverser and time-lag relays outputs from «1 to 240»
or maintained
An optional antenna Ref. AT8WAY can be added for the
The indentifier is associated to a memory position of user in
the reader or the remote system, which allows to identify the
person asking access
two ways flow
The 2 main frequencies associated to the Read technology of
proximity tag are 125KHz EM and 13.56MHz MIFARE.
The RT and LP readers are also
available in 2.45 GHz frecuency
The MIFARE tags have a memory more important than the
EM tags and can be used for others applications than access
control
The tags with MIFARE technology have the Read/Write
function ( can be reprogrammed) whereas the tags with
EM technology have the Read function only. These both
frequencies are subjected to standards.The 868MHz and
2.45GHz are used for the long range technologies.
ACIE
30
31
ACIE
CARACTERISTIQUES TECHNIQUES
IDS TAGS
& REMOTE CONTROLS
TECHNICAL FEATURES
IDS TAGS
& REMOTE CONTROLS
TECHNICAL FEATURES
Passive IDs patchs R20 range
Passive IDs tags CA301 range
PATCH format diameter 20mm
Transparent adhesive PVC finishing. No UID is
engraved
Requires programming
Ref. R20 : format EM 125KHz Read only
Ref. R20M : format MIFARE 13.56MHz Read/Write
Flexible format( CB) 86x54x0.8mm
White PVC finishing
UID number engraved in decimal and
hexadecimal
Ref. CA301 : format EM 125KHz Read only
Ref. CA301M : format MIFARE 13.56MHz Read/Write
Passive IDs bracelet BM405 Range
Passive IDs tags CL307 range
Rigid format 86x54x1.8mm
FormBRACELET SWATCH format diameter 65 to
74mm
Silicone finishing black, blue, green, red,
waterproof.
No UID is engraved. Requires programming
Ref. BM405: format EM 125KHz Read only
Ref. BM405M : format MIFARE 13.56MHz Read/
White PVC finishing with operculum for lace or strap clip .
UID number engraved in decimal and hexadecimal
Active IDs tags CA868
«Electronic
Ref. CL307 : format EM 125KHz Read only
Ref. CL307M : format MIFARE 13.56MHz Read/Write
Electronic toll system» format
Dimensions : 54X86X40mm
Black PVC finishing provided with the fixing clip lithium battery
CR2032
Front micro-switch M/A
Passive IDs keyrings BA403 range
No UID is engraved . Requires programming
Ref. CA868 : format 868MHz Read/Write
Ref. CA868-EM : format 868MHz Read/Write + 125KHz Read only
FKEYRING format 44x35x4mm
Ref. CA868-MIFARE: format 868MHz Read/Write + 125KHz Read
Black PVC finishing with stainless steel ring
only
UID number engraved in decimal and
hexadecimal
Ref. BA403 : format EM 125KHz Read only
Ref. BA403M : format MIFARE 13.56MHz Read/
Write
ACIE
32
Active IDs remote controls T868 range
Remote control format
Dimensions : 65x35x10mm
provided with the fixing clip
Blue PVC finishing with key ring.
No engraved UID.
Requires programming lithium battery CR2032
Programmable 1 , 2 or 4 channels. Témoin d’émission et de
réception.
Ref. T868 : format 868MHz Read/Write
Ref. T868-EM : format 868MHz Read/Write+ 125KHz Read only
Ref. T868-MIFARE : format 868MHz + 13.56MHz Read/Write
33
ACIE
POWER SUPPLIES
& VOLTAGE CONVERTERS
A security system is as worthwhile for its functional characteristics
as for its functioning in case of power cut.
Then, the sizing of the power supply and its battery ‘s capacity are
decisive to ensure a correct functionning of the apparels which
have to be supplied.
An energy balance is necessary
That’s why, it’s important to know the limits of high and low
tensions of the apparels to be supplied,their consumption during
a standard tension slot, the lenght of the cable needed to supply
the power and its physical characteristics.
Several additional power supplies can be necessary to reach the
needed power for the good functioning of the setting-up
34
35
ACIE
CARACTERISTIQUES TECHNIQUES
POWER SUPPLIES
& VOLTAGE
CONVERTERS
TECHNICAL FEATURES
COFFRETS ALIMENTATIONS
& CONVERTISSEURS
TECHNICAL FEATURES
Charger box 12V PAC5-12
Charger box 12V CCP 05 range
Typical secondary voltage
Key closing
Power on indicator
Power on indicator 12V
Battery indicator
Sealed wire-passes
Dimensions : 295x195x92mm
Only interior installation
Power supply : 220v
Charger : 12V CC 5A
Battery: 12V 17Ah not included
Typical secondary voltage
Format PLEXO : 194x135x75mm
Power on indicator
Installation environment interior only
Power supply 220v
Charger 12V CC 0.5A
Battery location 12V 1.2Ah
Ref. CCP05 : Battery 12V 1.2Ah not included
Ref. CCP05-B : Battery 12V ,1,2 Ah included
Charger box12V PAC1.5-12
Charger box 24V PAC1.5-24
Typical secondary voltage
Key closing
Typical secondary voltage
Key closing
Power on indicator
Power on indicator 24V
Battery indicator
Sealed wire-passess
Dimensions : 287x287x124mm
Only interior installation
Power supply : 220v
Charger : 24V CC 1.5A 2 x
Battery : 12V 7Ah not included
Power on indicator
Sealed wire-passes
Dimensions : 265x195x75mm
Only interior installation
Power supply : 220v
Charger : 12V CC 1.5A
Battery :12V 7Ah not included
Charger box 12V PAC3-12
Charger box24V PAC2.5-24
Typical secondary voltage
Key closing
Power on indicator
Power on indicator 12V
Battery indicator
Sealed wire-passes
Dimensions : 295x195x72mm
Only interior installation
Power supply:220v
Charger :12V CC 3A
Typical secondary voltage
Key closing
Power on indicator
Power on indicator 24V
Battery indicator
Sealed wire-passes
Dimensions : 285x285x124mm
Only interior installation
Power supply : 220v
Charger : 24V CC 2.5A
2 x Batteries 12V 7Ah not included
ACIE
36
37
ACIE
POWER SUPPLIES
& VOLTAGE
CONVERTERS
TECHNICAL FEATURES
Charger box 24V PAC5-24
PUSHBUTTONS &
CASES
OF UNLOCKING
Additional power supply
Key closing
Power on/off indicator
A door which is controlled by a reader in entrance isn’t
Power on indicator 24V
necessary controlled in exit.Usually ,the door is shut after the
Battery indicator OK and default
user has come in, so you have to find way to go out without
Sealed wire-passes
Dimensions : 397x287x85mm
generating any alarm of forced door if the position of the
Only interior installation
door is supervised by a magnetic contact. A push button
Power supply: 220v
can be connected to the entrance door dedicated to the
Charger : 24V CC .5A
2 x Batteries 12V 7Ah not included
entrance request, standalone reader or the door controller’s
interface for the systems. .The event of the exit request by
push button allows then the opening of the door without
Voltage converter CONVERT24-12
generating a forced door alarm.The exit requests can be
made by pushing a button or by approaching a captor.
The controlled doors of building receiving a public( ERP)
have to be equipped with an additional manual relase for
Electronics sheathed thermo retracted
emergency unlocking.
translucent.
Dimensions : 42X15m
Installation environment : 0° to 50°C.
The accessibilty is an essential factor of the social and
Input up to 30V DC or AC
professional integration for the physically handicapped
output12VDC 300 mA
persons.Obligation since 1975,the law from 2005,February
Charger box SPECIAL VIDEO PROTECTION 4 or 9 OUTPUTS
AC-CCP-4C
Additional power supply
Closing with key
Sector presence indicator
Jointed wire grommets
Dimensions : 203x163x74mm
Installation environment indoor only
Power : 220v
Charger : 12V CC 3A
Battery :12V 7Ah à prévoir
Power supplied on 4 outputs protected by fuse wires
,11th( for the eguality of the rights and opportunities, the
participation and citizenship of the handicapped persons.)
holds the generalized principe of accessibility:» the access to
everything for everybody».
AC-CCP-9C
Additional power supply
Closing with key
Sector presence indicator
Jointed wire grommets
Dimensions : 360 x195 x75mm
Installation environment indoor only
Power : 220v
Charger : 12V CC 8A
Battery :12V 7Ah not included
Power supplied on 9 outputs protected by fuse wires
ACIE
38
39
ACIE
CARACTERISTIQUES TECHNIQUES
PUSHBUTTONS &
CASES
OF UNLOCKING
TECHNICAL FEATURES
PUSHBUTTONS &
CASES
OF UNLOCKING
TECHNICAL FEATURES
Surface mounted push button BOPO-IS
Push button switch BOPO
Push button switch
Iluminated push button mounted on stainless steel housing and face
Polycarbonate finishing
Blue light ring 12V
beige
Inox finishing with direction finger symbol
Engraved key symbol
Dimensions : Housing 84x41x45mm
Dimensions : 86x86x46xmm
Insulated contacts C-NO and C-NC 3A on 250V
Security screw fixing
Ref. BOPO-IS-PMR : same as BOPO-IS but in compliance with the PMR
standard
Free hand pushbutton
BOPO-S-IR
Push button by pressing action BOPO-S
Free-hand button approach detector from 3 to 12 cm
Iluminated push button
Power supply 12Vcc 35mA
Blue light ring 12V
Output relay NO/NC 1A sous 24Vcc
Drilling diameter : 22mm
Drilling diameter : 19mm
Depth : 38.9mm
Depth : 40mm
Insulated contacts C-NO and C-NC
Detection and time delay distance adjustable by potentiometers
2 colors indicators
Conditions of use IP65 : -20 to 70°C
Built in Free hand push button BOPO-I-IR
Built-in Push button BOPO-I
Free-hand built-in button od approch detector from 3 to 12cmPushbutton
Iluminated push button mounted on stainless steel facade
12Vcc 35mA
Blue light ring 12V
Output relay NO/NC 1A sous 24Vcc
Inox finishing with direction finger symbol
Inox finishing with direction finger symbol
Dimensions :
Front dimensions : 84x41mm
- Front 84x41mm
Depth : 40mm
- Depth 38.9mm
Detection and time delay distance adjustable by potentiometers
Insulated contacts C-NO and C-NC 3A on 250V
2 colors indicators
Security screw fixing
Conditions of use IP65 : -20 to 70°C
Security screw fixing
Ref. BOPO-I-PMR : same as BOPO-I but in compliance with the PMR
standard
ACIE
40
Ref. BOPO-I- IR-PMR : same as BOPO-I-IR but in compliance with the PMR standard
41
ACIE
PUSHBUTTONS &
CASES
OF UNLOCKING
TECHNICAL FEATURES
Free-hand button BOPO-IS-IR
LOCKINGS
& ARTICULATED
ARMS
Free-hand button approach detector from 3cm to 12 cm on covered
case. Power supply 12Vcc 35mA
Several means of lockings are used in the management of
Output relay NO/NC 1A on 24Vcc
Inox finishing with direction finger symbol
Front dimensions : 84x41x45mm
Detection and time delay distance adjustable by potentiometers
2 colors indicators
Conditions of use IP65 : -20 to 70°C
Security screw fixing
Ref. BOPO-IS- IR-PMR : same as BOPO-IS-IR but in compliance with the
PMR standard
accesses.
The most commonly used are the electric strikes and the
electro magnetic locks
A wide range of aspects and options existes in each line
of products. The fitter has to make the choice the more
adapted according to the access which has to be controlled.
A special attention has to be given to the equipements of
Built in push button
BOPO-I-PMR
Push button surface mounted
BOPO-IS-PMR
the doors from buildings which are open to the public, to
the exit door, to the senditive doors according to the level of
controlled required.
Thus, do not propose electric stikes or electromagnetic
NO/NF enlightened push button monted
on an inox plate 20/10ème in accordance
with the disabled persons
Back box included
Engraved in braille for the blind persons
Sound indicator for opening (sound level
85dBA at 10 cm)
The system can receive an exterior contyrol
indicator
4 TORX rounded scews included M4 x 20
torx device
Dimensions : H104 x L44 x P53mm
Enlightened push button NO/NF mounted
on an inox plate 20/10ème in accordance with
the law regarding the disabled persons
Engraved in braille transcription for the
blind persons
Sound indicator for opening (sound level
85dBA at 10 cm)
The system can receive an exterior contyrol
indicator
4 TORX rounded scews included M4 x 20
torx device
Dimensions : H110 x L40 x P48 mm
locks for the doors where the unicity of passage has to be
guaranteed, rather prefer revolving door or tripods.
Prefer means of lockings which have standby time in case of
power cut.
In any case, the knowledge of the current law regarding the
outfeed has to be considered
Emergency unlocking box serial 2211**
Distorting box by pressure with memory status indicator
Locked door
Unlocked door
Green ABS finishing
Reset by key tool
Ref. 221122 : 1 contact NO et NC on 250v Ref. 221123 : Idem
221122 but 2 contacts
Conditions of use IP44 : - 30 to 70°C
Dimensions : 86x87x52mm
ACIE
42
43
ACIE
CARACTERISTIQUES TECHNIQUES
LOCKINGS
& ARTICULATED
ARMS
TECHNICAL FEATURES
TECHNICAL FEATURES
LOCKINGS
& ARTICULATED
ARMS
Electro-magnetic locks Serial AC550
Electric strikes GA serial
Invertible electric strike
Invertible INOX Headstall included
Dimensions : Electric strike
30x17x73mm Têtière 250x21mm
Ref. GA20 : transmission unlocking 12v 580mA
Ref. GA22 : same as GA20 but with memory control and back stricke
contact and 620mA
Ref. GA26 : Unlocking on failure 12v 280mA
Ref. GA28 : Idem GA22 but 290mA
Covered assembly
Electro-magnet dimensions: 265x70x38mm
Counter-plate:175x61x13mm
Power supply : 12/24Vcc 270/180mA
Hall Effect contact position and led.
Assembly accesories not included:
Ref. AC550ZL :Fixing brackets Z and L for AC550CTC
Dimensions : 180x70x70mm 180x75x70mm 242x35x42mm
Articulated arm ACFP640
Electro-magnetic locks serial AC300
Ref. AC300 : Covered assembly,
Electro-magnet dimensions: 242x52x25
Counter-plate: 158x45x13 12/24Vcc 270/180mA
Ref. AC300ENC : built-in assembly
Electro-magnet dimensions : 46x248x23mm
Counter-plate: 158x45x13 mm 12Vcc 350mA
Assembly accesories not included:
Ref. AC300ZL : Fixing brackets Z and L for AC300CTC
Dimensions : 160x50x50mm 160x50x57mm 242x35x42mm
ACIE
44
45
ACIE
EW
N
ACCESSORIES
TRANS-SMS
Not bigger than its SIM card,
the transmitter interface
The configurations of the setting-ups and the need of the
fits to all the systems you want to
TRANS-SMS
clients are often different,that’s why it’s important to be
watch over or control.
able to adapt the functionning of an equipment and its
installation.
Thus many interfaces with additional functionalities are
available.
SIM card not
included .
Operator of your
choice.
WATCH OVER
CONTROL
2 programmable inputs will send you
personalized SMS alert messages.
Do not hesitate to submit your specific needs to one of ours
technical advisers.
1 programmable output will react to your calls or
SMS through simple recognition of the calling
number , avoiding the call being invoiced.
Temporary or permanent
the installation of the
TRANS-SMS transmitter will
be very helpful.
®
ACIE
Sécurité
Available on the
App Store
THE ACCESS CONTROL SOLUTION
TRANS-SM
46
ACIE
47
ACIE
CARACTERISTIQUES TECHNIQUES
ACCESSORIES
TECHNICAL FEATURES
Universal SMS transmitter TRANS-SMS
ACCESSORIES
TECHNICAL FEATURES
Anti-overvoltage SEPRO
Dimensions : 80 x 60 x 30mm
Power supplies 2 x CR123 included or through
adaptator 220v 12v ( not included)
Programmed through SMS
GSM/GPRS : Quad band EGSM 900/1800-850/1900 MHz
National operator SIM card, PIN code desactivated
2 programmed inputs NF or NO
1 M/A function through push button or through SMS or
through schedule
1 transistorized output for relay control* through SMS or
through recognition of calling number (up to 50 N°)
Printed circuit under heat shrinkable tube.
Dimensions : 40X15m
Installation environment : 0° à 50°C.
No power supply
Only one contact to the ground is needed..
Come in before the ELA+ bus’ branch which has to be protected.
Come in before the reader which has to be protected between the
Wiegand or Dataclock datas’s wires
*The relay is receivable on the TRANS-SMS only if supplied external 12V and no with
CR123 battery.
Radio accessory
Memory transfer key MEM-01
AT868
Accesory for obstacle crossing with radio-receiver serial RT868
Coaxial cable 50ohms of 1m which can be extended.
Basis and antenna ABS
Hight : 240mm
Basis depht : 115mm
Direct connection on the receiver terminal.
users’ memory transfer key for readers serials:
-LP
-RT
-RX :
Printed circuit appearence
No power
Free-hand accessory VL AT8WAY
2nd antenna kit for receiver LP868 serial.
Coaxial cable 50ohms of 1m which can be extended.
Delivered with connection box, 90°antenna mast and fixing
stapes.
Make the two-way flow detection possible on only
one LP868 reader.
Direct connection on the receiver terminal.
Junction boxes BODER serial
Dual presentation interfaceDCW2R
Polycarbonate housing:: 105x 85x40mm
One relay driver on one user’s dual indentification.
PLEXO format box
Opening detection contact
Conditions of use IP54
Réf. BODER1: dimensions : 110x100x80mm
Réf. BODER1-B : same BODER1 but with 14 pairs of terminals
Réf. BODER2 : dimensions : 194x135x75mm
Réf. BODER2-B : same BODER2 but with 30 pairs of terminals
Come in between the Wiegand or Dataclock reader and the door controller.
Transparent mode for the users which are not allowed to the dual
presentation.
Up to 200 allowed users
Installation environment : IP65 - 30° to 50°C
Power supply : 12/24V CC 20 to 100mA
2 relay outputs programmable Wiegand and Dataclock Communication
ACIE
ACCESSOIRES
48
ACCESSOIRES
49
ACIE
ACCESSORIES
TECHNICAL FEATURES
SYSTEMES VIGIK
Door loop FLEX serial
Door loop with box input output
The VIGIK system is a concept from the Post.
Ref. FLEX-M : 40 cm nickel internal diameter 10mm
The principle is to replace the T10 pass at the entrance of
Support post for reader PO401
Support post for reader
Dimensions :
the buildings by a 13.56MHz RFIF key in order to control the
rights ans copies.
The companies which have access to the buildings, such as
- Post 1100x60x40mm
the Post, the emergency services, have specific rights, usually
- Platine 90x90mm
few hours by day for selected buildings in a selected area.
Stainless steel, epoxy paint
These tags are called « service tags»
finish
Support for readers serials:
-SU
The residents of the building have specific rights which
- PM
- PROX
usually are dedicated only to the building of their residence.
These tags are called» residents tags»
AC-B120 Terminal
Support post to fix reader
Dimensions :
- Colunn 1200 X 100 mm
- Platine 250 x 200 mm
- Base 250 x 200 mm
Thermo lacquering in the oven grey titanium
Bare plate to be drilled included plaquee 200 x 130
mm
ACIE
ACCESSOIRES
50
SYSTEMES
VIGIK
51
ACIE
CARACTERISTIQUES TECHNIQUES
VIGIK SYSTEMS
TECHNICAL FEATURES
Kit VIGIK-MI
VIGIK SYSTEMS
TECHNICAL FEATURES
TALOS-EAB Keypad
Panel unit kit with a remote reading head 13.56MHz
Ref. VIGIK-MI-W : idem VIGIK-MI + WIEGAND access control 34
bytes
Dimensions :
- front : 220 x 105 x 2 mm
- back : 200 x 90 x 40 mm
Finition : inox 20/10éme
2 domed scews and TORX tool included
Hole in the front for :
- TALOS serial Keypads
- T25 or VIGIK head
The VIGIK serial systems cope with the
characteristics and functionalities
of the VIGIK specifications
TALOS-SAB keypad
Kit VIGIK-MIEM
Dimensions :
- front : 220 x 105 x 2 mm
- back : 200 x 105 x 40 mm
Panel unit kit with a remote reading head
Finition : inox 20/10éme
2 domed scews and TORX tool included
.twin frecuency, 13.56MHz and 125KHz
Ref. VIGIK-MIEM-W: idem VIGIK-MIEM + WIEGAND access
Hole in the front for :
control 34 bytes
- TALOS serial Keypads
- T25 or VIGIK head
ACIE
SYSTEMES
VIGIK
52
SYSTEMES
VIGIK
53
ACIE
U
EA
UV
NO
PONTS RADIO
INTERMAT-PRO
• Dimensions : 1005 x 270 x 275 mm
• Température : -20°C à +50°C
• Etanchéité : IP65
• Alimentation : 230V CA
• Utilisateurs : 3000
• Capteur d’image CCD céramique B/N de 1/2“
• Résolution : 782 x 582 pixels
• Flash LEDs infrarouges synchronisé avec le temps d’exposition
du capteur CCD
• Filtre infrarouge pour intempérie
Les installations de sécurité sont aujourd’hui de plus en plus
«étirées» et le passage de cable peut rapidement devenir un
probleme, tant d’un point de vue technique que de coût.
La solution des ponts radio présente alors tout son intérêt.
Seules quelques règles d’usage pour leur mise en oeuvre
s’imposent d’évidence ; distance entre les 2 points à relayer
TOT E M I N T E R M AT - Lecteur de plaques d’immatriculation
correspondante au regard des performances du pont radio
utilisé et une implation des vis à vis à vue champ libre.
Une installation SIMPLE
Constitués d’un émetteur et d’un récepteur, ils permettent
de transporter différents types de signaux électriques.
3,5 m
3,5 m
Automatisme
INTERMAT-PRO
Vidéo Analogique, RS232, RS485, TCP/IP, Wiegand, Contacts
Secs.
Un pont radio peut disposer de plusieurs canaux de
transmission et peut être relayé par un autre pont radio et
rebondir ainsi jusqu’à, peu de vraies limites..
Détection de véhicule
®
ACIE
Sécurité
Available on the
App Store
la solution contrôle d’accès
INTERMAT
PRO
54
ACIE
PONTS
RADIO
55
ACIE
CARACTERISTIQUES TECHNIQUES
PONTS RADIO
TECHNICAL FEATURES
Radio bridge
TECHNICAL FEATURES
WIN-RAD
Wireless CCTV Security system 5,8GHz mono directionnal
POWER
AC-RADA-1000
• Kit Transmitter Receiver
• 1 analogical video canal
• 8 selectionnable channels
• 1 Km long range
• 12Vcc 360mA / device
• Between -20 to 50°C
POWER
AC-RADA-3000
• Kit Transmitter Receiver
• 1 analogical video signal
• 8 selectionnable channels
• 3Km selectionnable channels
• 12Vcc 500 mA / device
• Between -20 to 50°C
• Kit Transmitter Receiver
• 4 analogical video signal
• 8 selectionnable channels
• 2Km long range
• 12Vcc 800 mA / device
• Between -20 to 50°C
POWER
Range up to 50m free field of vision with
integrated antenna or 100 m free field of vision
with the AT868 omni-directional external antena.
VIDEO - AUDIO
868MHz
Transmitter/Receiver for Wiegand or Dataclock
Wireless CCTV
Security system
AC-RADA-4-RX/TX
EQUIPMENT
VIDEO
EQUIPMENT
VIDEO
=>1 Km <=
COAXIAL
COAXIAL
EQUIPMENT
VIDEO
=>3 Km <=
COAXIAL
COAXIAL
POWER
12VCC
12VCC
EQUIPMENT
VIDEO
POWER
12VCC
12VCC
EQUIPMENT
VIDEO
POWER
12VCC
12VCC
EQUIPMENT
VIDEO
=>2 Km <=
4 COAXIAL
4 COAXIAL
Transmitters and receivers need a
local 12Vcc
power supply.
RS485/RS232
Wireless CCTV Security system 869MHz bi-directional
AC-RADA-485
• Modem (2 to be included)
• 1 data bus RS485 / RS232
• 10 selectionnable channels
• Portée 6Km champs libre à vue
• 12Vcc 400 mA / appareil
• Fonctionnel entre -20 à 50°C
12VCC
12VCC
=>6 Km <=
EQUIPMENT
RS485/RS232
EQUIPMENT
RS485/RS232
RS485
RS485
IP-ETHERNET
Wireless CCTV Security system5,8GHz bi-directional
AC-RADN2
Radio bridge IO8-RAD
• Kit Transmitter Receiver
• 1 IP network up to 20Mbps
• Internet or Ethernet
•
• 8 selectionnable channels
• 2 Km long range
• Power supplies provided
• Between -20 to 50°C
220V
220V
INJECTOR
POE
=>2 Km <=
INJECTOR
POE
IP NETWORK
EQUIPMENT IP
ACCESSOIRES
ACCESSORIES
868MHZ multi-applications
Bi-directional transmitter/receiver for 8 relays,8 inputs by
transmitter and receiver.
Range up to 50m free field of vision with intergrated
220V
Antenna 5.2 GHz Omni directional
Gain 12dBi.
Up to 3500m with AC-RADN2 kit
INJECTOR
POE
220V
INJECTOR
POE
IP NETWORK
EQUIPMENT IP
AC-ANT-OMNI
220V
Antenna 5.2 GHz Directional Gain
24dBi.
Up to 5000m with AC-RADN2 kit
INJECTOR
POE
EQUIPMENT IP
AC-5-DIR
antena or 100m free field of vision with AT868
=>3,5 Km <=
=>5 Km <=
220V
INJECTOR
POE
I NETWORK
omnidirectional
external antena.
ACIE
56
57
ACIE
ACIE
58
59
ACIE
®
ACIE
www.acie-securite.com
Our distributor
ISO 9001
BUREAU VERITAS
Certification
Nº ES021687-B
Download