Datasheet - Functional Devices, Inc.

advertisement
(800) 888-5538
sales@functionaldevices.com
www.functionaldevices.com
SWITCH / CIRCUIT BREAKER COMBOS
Enclosed Power Control Center, 4 Amp Switch /
Circuit Breaker, 120 Vac, 2 Outlets, Terminals
Outlets will be controlled
by switch/breaker when
jumper is in this position.
Output Hot “H” is controlled
by switch/breaker.
PSPW2RB4
Enclosed Power Control Center, 4 Amp Switch /
Circuit Breaker, 120 Vac, 2 Outlets, Wires
Outlets will always be
energized when jumper
is in this position.
Outlets will be controlled
by switch/breaker when
jumper is in this position.
INPUT
H
Enclosed Power Control Center, 10 Amp Switch /
Circuit Breaker, 120 Vac, 2 Outlets, Wires
Outlets will always be
energized when jumper
is in this position.
Outlets will be controlled
by switch/breaker when
jumper is in this position.
G
N
OUTPUT
H
H
ALWAYS HOT
BLUE = LOAD
Blue wire is controlled
by switch/breaker.
N
Circuit Breaker
Terminals
PSPT2RB4
4 Amps
PSPT2RB10
10 Amps
•
•
PSPW2RB4
4 Amps
PSPW2RB10
10 Amps
Wires
•
•
SPECIFICATIONS
Operating
Temperature:
Humidity Range:
Circuit Breaker:
Dimensions:
G
BLUE = LOAD
Blue wire is controlled
by switch/breaker.
PSP SERIES
Model #
G
Output Hot “H” is controlled
by switch/breaker.
INPUT
G
N
PSPW2RB10
Black
Wire
Black
Wire
White
Wire
Green
Wire
N
H
SWITCHED
H
N
GND “G” and Neutral “N” pass from
INPUT to OUTPUT uninterrupted.
OUTPUT
H
Blue
Wire
N
ALWAYS HOT
G
G
SWITCHED
G
SWITCHED
N
OUTPUT
Blue
Wire
GND “G” and Neutral “N” pass from
INPUT to OUTPUT uninterrupted.
H
White
Wire
H
Made in USA
Meets
“Buy American”
of ARRA 2009
Outlets will be controlled
by switch/breaker when
jumper is in this position.
INPUT
Green
Wire
N
SWITCHED
G
Outlets will always be
energized when jumper
is in this position.
OUTPUT
ALWAYS HOT
INPUT
Enclosed Power Control Center, 10 Amp Switch /
Circuit Breaker, 120 Vac, 2 Outlets, Terminals
ALWAYS HOT
Outlets will always be
energized when jumper
is in this position.
PSPT2RB10
Wires:
Approvals:
Housing Rating:
Terminals:
-30 to 140° F
5 to 95% (noncondensing)
4 Amp Max. or 10 Amp Max.
4.000˝ x 4.000˝ x 1.800˝
(w/ .500˝ NPT Nipple - PSPW2RB4
& PSPW2RB10)
16˝, 600V Rated (PSPW2RB4 & PSPW2RB10)
UL Listed, UL916, C-UL, CE, RoHS
UL Accepted for Use in Plenum, NEMA 1
Ground “G˝ and Neutral “N˝ pass from INPUT
to OUTPUT uninterrupted.
OUTPUT (PSPT2RB4 & PSPT2RB10)
Hot “H˝ is controlled by the switch/breaker.
Notes:
• Indicator light will illuminate when switch/breaker is ON
(RESET position) indicating power has been transferred from
INPUT to OUTPUT by the switch/breaker. If it is desired for the
indicator light to be illuminated continuously to indicate the
presence of input (Line) power, INPUT and OUTPUT may be
reversed -- connect input power from line to OUTPUT and
connect output load to INPUT (operation of the jumpers
above also reverses).
POWER
CONTROL
PSPT2RB4
102715