INSTALLATION INSTRUCTION ACCIAIO ® BX/HZ920 F L U O R E S C E N T 120V/277V, 347V or 480V Input T5, T5HO, T8 WET LOCATION / IP66 HZ models: Class I, Division 2, Class I, Zone 2 Groups A, B, C & D, Hazardous locations R C US Chain mount (chain optional) Surface mounting bracket Safety cable EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Steel Housing Die-cast aluminum end cap Model: Operation BX920, BX902S, HZ920, HZ920S SA (AC & Emergency) *not available on HZ models Lamps Input 217W T8 214W T5 224W T5HO 228W T5 232W T8 254W T5HO 120V / 277V 347V or 480V Tempered glass lens Stainless steel lock screw IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 040113 INSTALLATIONGUARDS 1. Make sure the main power is off. ® 2. Attach and secure ACCIAIO mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cables to safety brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. RELAMPING 1. Detach mounting brackets from housing having the fixture hang from safety cables (If there is 48” clearance on site this process is not necessary see) (figures 2, 3 & 4) 2. Loosen stainless steel screw from NON-FEED end cap and remove end cap off. 3. Remove security crossbar (up – out motion) 4. Partially or completely slide out rail system until lamps are accessible. 5. Repeat the same process in reverse to close and seal the unit. Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 Safety cable G N L 2 Connect wires to main power. (72” standard line cord provided) power is off 4 Attach mounting brackets to surface. G N L Snap fixture to brackets. 3 5 Safety bracket G N BLACK / HOT WHITE / NEUTRAL 6 GREEN /GROUND 42.00 Canopy kit (provided by others) 42.00 21.00 L 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cables to safety brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. Fixture completely installed. RELAMPING 1 NOTE: step1 can be skipped IF YOU HAVE 48“ BETWEEN UNITS 2 Detach luminaire from surface mount brackets using a flathead screwdriver. Unit is held by two safety cables that allow the ACCIAIO® to drop down evenly approximately 12” for easy accesibility. 3 Loosen stainless steel lock screw to release non-feed, die-cast end cap. 4 Remove crossbar bracket in an up and out motion for access to the ballast and lamp rail system. Grasp here and pull Ratcheted lamp sockets must be turned to disengage and remove lamps Reverse all steps to close and secure ACCIAIO®. INSTALLATION INSTRUCTION ACCIAIO ® BX/HZ940 F L U O R E S C E N T 120V/277V, 347V or 480V Input T5, T5HO, T8 WET LOCATION / IP66 HZ models: Class I, Division 2, Class I, Zone 2 Groups A, B, C & D, Hazardous locations R C US Chain mount (Chain optional) Surface mounting bracket Safety cable EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Model: Operation Die-cast aluminum end cap BX940, BX940S, HZ940, HZ940S HT (AC Only) SA1 (AC & Emergency - one lamp) SA2 (AC & Emergency - two lamp) *not available on HZ models Steel Housing Lamps Input 432W T8 428W T5 454W T5HO 120V / 277V 347V or 480V Tempered glass lens Stainless steel lock screw IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 040113 INSTALLATIONGUARDS 1. Make sure the main power is off. ® 2. Attach and secure ACCIAIO mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cables to safety brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. RELAMPING 1. Detach mounting brackets from housing having the fixture hang from safety cables (If there is 48” clearance on site this process is not necessary see) (figures 2, 3 & 4) 2. Loosen stainless steel screw from NON-FEED end cap and remove end cap off. 3. Remove security crossbar (up – out motion) 4. Partially or completely slide out rail system until lamps are accessible. 5. Repeat the same process in reverse to close and seal the unit. Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 2 Connect wires to main power. (72” standard line cord provided) power is off Safety cable 4 Attach mounting brackets to surface. G N L Snap fixture to brackets. 5 3 Safety Bracket 42.00 G N BLACK / HOT WHITE / NEUTRAL 6 GREEN /GROUND Canopy kit (provided by others) 42.00 L 21.00 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Connect safety cables to safety brackets (top of the fixture). 4. Connect safety cables to already installed mounting brackets. 5. Bring the fixture up and snap mounting bracket onto housing side channels. 6. Connect labeled wires to main power. Fixture completely installed. RELAMPING 1 NOTE: step1 can be skipped IF YOU HAVE 48“ BETWEEN UNITS 2 Detach luminaire from surface mount brackets using a flathead screwdriver. Unit is held by two safety cables that allow the ACCIAIO® to drop down evenly approximately 12” for easy accesibility. 3 Loosen stainless steel lock screw to release non-feed, die-cast end cap. 4 Grasp here and pull Remove crossbar bracket in an up and out motion for access to the ballast and lamp rail system. Ratcheted lamp sockets must be turned to disengage and remove lamps Reverse all steps to close and secure ACCIAIO® INSTALLATION INSTRUCTION ACCIAIO ® BX/HZ950 single COMPACT FLUORESCENT 120V/277V, 347V or 480V Input WET LOCATION / IP66 DHZ models: Class I, DIvision 2, Class I, Zone 2 Groups A, B, C & D, Hazardous locations R C 2 Chain mount (Chain optional) 1 Surface mounting bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Model: Die-cast aluminum B end cap B Steel Housing Operation Lamps Input BX950, BX950S, HZ950, HZ950S HT (AC Only) 236W CF 255W CF 120V/277V 347V or 480V Tempered glass lens Stainless steel lock screw IMPORTANT SAFEGUARDS INSTALLATIONGUARDS WARNING A 1. Make sure the main power is off. 2. AAttach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Bring the fixture up and snap mounting bracket onto housing side channels. 4. Connect labeled wires to main power. No User serviceable parts. Refer service to a qualified service technician. This document property of and contains proprietary to Beghelli, Inc. It is submitted in confidence Readis the instructions prior information to installing and /or operating this device.and is to be used solely for the purpose for which it was furnished and returned upon request. This document and such information is not to be reproduced, transmitted, disclosed, or used otherwise in whole or in part without prior authorization of Beghelli, Inc. The recipient's acceptance of this document shall be considered an Installation should be written performed by a licensed electrician / installer agreement to the foregoing. in accordance with local codes. PART NAME Beghelli 3250 Corporate Way IMPORTANT SAFETYGUARDS Miramar, Florida 33025 UNLESS OTHERWISE SPECIFIED ALL DIMENSIONS = INCHES MATERIAL Ph: 954 442 6600 Fx:954 442 6677 www.beghelli.com FINISH ANGLES + 1 When using electrical equipment, basic safety precautions should DATE DRAWN BY DWG NO always beTOLERANCES: followed including the following: .X = + 0.030" Miguel Angel Pino 11/14/2011 .XX = + 0.015" SIZE SCALE REF NO SHEET = + 0.005" READ AND .XXX FOLLOW ALL SAFETY INSTRUCTIONS DO NOT SCALE 2 1 - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 040113 REV RELAMPING 1. Loosen stainless steel lock screw from feed end cap 2. Release feed, die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com US INSTALLATION 1 power is off Attach mounting brackets to surface. G WHITE / NEUTRAL G N N L 3 Snap fixture to brackets. BLACK / HOT GREEN /GROUND Canopy kit (provided by others) 4 2 Connect wires to main power. (72” standard line cord provided) L Fixture completely installed. 1. Make sure the main power is off. 2. Attach and secure ACCIAIO® mounting brackets to surface. Use appropriate fasteners. 3. Bring the fixture up and snap mounting bracket onto housing side channels. 4. Connect labeled wires to main power. RELAMPING 1 2 Loosen stainless steel lock screw from feed end cap 3 Grasp here and pull Release feed, die-cast end cap. 4 Slide out rail system to access the ballast and lamps. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® INSTALLATION INSTRUCTION ACCIAIO ® BX/HZ950 duo COMPACT FLUORESCENT 120V/277V, 347V or 480V Input WET LOCATION / IP66 HZ models: Class I, Division 2, Class I, Zone 2 Groups A, B, C & D, Hazardous locations R C US Surface mounting bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMP / INPUT Die-cast aluminum end cap MA NIT RU STE Model: SL E AV T NI Operation U Lamps Input BX950, BX950S, HZ950, HZ950S HT (AC Only) 436W CF 455W CF 120V/277V 347V or 480V Steel Housing Tempered glass lens Jumper cable (with watertight connectors) Stainless steel lock screw IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: INSTALLATIONGUARDS 1. Make sure the main power is off. 2. Attach and secure ACCIAIO mounting brackets to surface. (Use appropriated fasteners) 3. Bring MASTER fixture up and snap mounting brackets onto housing side channels. 4. Bring SLAVE fixture up and snap mounting brackets onto housing side channels. 5. Connect MASTER and SLAVE using jumper cable with watertight connectors. 6. Connect MASTER fixture to main (AC) power following labels information. 7. Turn ON power. READ AND FOLLOW ALL SAFETY INSTRUCTIONS RELAMPING - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. 1. Disconnet MASTER and SLAVE from jumper cable loosen stainless steel lock screw from feed end cap. 2. Release feed, die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO® SAVE THESE INSTRUCTIONS! 040113 Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION 1 G power is off N L WHITE / NEUTRAL BLACK / HOT Attach mounting brackets to surface. GREEN /GROUND 6 2 Connect wires to main power. (72” standard line cord provided) G N L Snap fixture to brackets. 14.370 3-4-5 Canopy kit (provided by others) 3.150 Fixture completely installed. 1. Make sure the main power is off. 2. Attach and secure ACCIAIO mounting brackets to surface. (Use appropriated fasteners) 3. Bring MASTER fixture up and snap mounting brackets onto housing side channels. 4. Bring SLAVE fixture up and snap mounting brackets onto housing side channels. 5. Connect MASTER and SLAVE using jumper cable with watertight connectors. 6. Connect MASTER fixture to main (AC) power following labels information. 7. Turn ON power. RELAMPING 1 2 Disconnet master and slave from jumper cable, loosen stainless steel lock screw from feed end cap. 3 Release feed, die-cast end cap. 4 Grasp here and pull Slide out rail system to access the ballast and lamps. 12.539 Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO®. INSTALLATION INSTRUCTION ACCIAIO ® BX/HZ960 Flood COMPACT FLUORESCENT 120V/277V, 347V or 480V Input WET LOCATION / IP66 HZ models: Class I, Division 2, Class I, Zone 2 Groups A, B, C & D, Hazardous locations Mounting Bracket R C Aluminum non-feed die-cast end cap U Bracket EACH MODEL NUMBER CONSISTS OF THE FOLLOWING: SERIES / OPERATION / LAMPS / INPUT Aluminum feed die-cast end cap Model: Steel Housing Operation Lamps Input BX960, BX960S, HZ960, HZ960S HT (AC Only) 236W CF 255W CF 120V/277V 347V or 480V Stainless steel lock screw Tempered glass lens IMPORTANT SAFEGUARDS WARNING No User serviceable parts. Refer service to a qualified service technician. Read instructions prior to installing and /or operating this device. Installation should be performed by a licensed electrician / installer in accordance with local codes. IMPORTANT SAFETYGUARDS When using electrical equipment, basic safety precautions should always be followed including the following: READ AND FOLLOW ALL SAFETY INSTRUCTIONS - Do not let power cords touch hot surfaces. - Do not mount near gas or electric heaters. - Equipment should be mounted in locations and at heights where unauthorized personnel will not readily subject it to tampering. - The use of accessory equipment not recommended by Beghelli Inc., may cause an unsafe condition, and will void the warranty. - Do not use this equipment for other than its intended purpose. - Servicing of this equipment should be performed by qualified service personnel. SAVE THESE INSTRUCTIONS! 040113 US INSTALLATIONGUARDS Make sure the main power is off: Loosen lock screw and detach feed die-cast end cap. Loosen set screws / Slide mounting brackets onto housing through channels. Position mounting brackets 12” apart (keep set screws loose until final adjustment). Mount U bracket on desired surface against the containment and use proper fasteners (provided by others). Mount the fixture on installed U bracket using provided screws. Tighten set screws. Adjust desired angle. Connect labeled wires to main power. Turn ON power. RELAMPING 1. Loosen stainless steel lock screw from feed end cap and release. 2. Release feed die-cast end cap 3. Slide out rail system to access the ballast and lamps. 4. Disengage and remove lamps from sockets. Reverse all steps to close and secure ACCIAIO®. Beghelli Canada Inc. 3900 14th Avenue Markham, Ontario L3R 4R3 Canada Tel (905) 948-9500 Fax (905) 948-8673 www.BeghelliLuce.com INSTALLATION Containment tab 1 2 Loosen only (Do not remove) Set screw (2) Slide mounting brackets onto housing up to containment tab. Detach feed die-cast end cap. 3 4 12.0” Angle adjustment Tighten set screw N L Position brackets at (12”) apart attach feed die-cast end cap. Use proper fasteners (provided by others) G Final mounting and adjustment. RELAMPING 1 2 Loosen stainless steel lock screw from feed die-cast end cap. 3 Release feed die-cast end cap. 4 Grasp here and pull Slide out rail system to access the ballast and lamps. Disengage and remove lamps from sockets Reverse all steps to close and secure ACCIAIO®.