Process Control Signals Hazardous, NEMA & IP Definitions Visual Signals Electronic Signals Edwards® 5540M Adaptatone® Millennium Central Tone Generator PLC Compatible* Features • PLC compatible - No external relays required • Stand-alone. 27 tone capability - No additional tone modules needed • Four 3 pulse temporal tones • New "soft" tones • Four Input, Four Output • Corrosion resistant electrostatic heat flowed epoxy finish • Captive Components • Centralized programmable tone selection • System-wide priority tone selection Description • Models available for 24V DC/AC 50/ 60 Hz, 120V AC 50/60 Hz, 120V to 240V AC and 125 to 250V DC • 24V DC battery backup terminals provided • Short Circuit protected Installation System components are designed for either 1/2" (13mm) conduit or surface mounting. See Adaptatone Signaling Installation, pages 4-43 & 4-44. Applications Adaptatone Signaling Systems are designed for industrial applications The Edwards 5540M Millennium Central Tone Generator has been designed for applications where simultaneous signaling of a high decibel, heavy duty signal is required. The Millennium Central Tone Generator produces the 27 standard Adaptatone sounds. The tone generator assures a synchronous signaling sound from all remote speakers. The four tones may be activated from field-wired, normally open contacts, or a 24VDC or 120VAC external voltage source such as an output of a PLC. The tones may be selected by setting miniature dip switches within the unit. The programmed tones operate on a pyramid-type priority system. Normally open contacts can be obtained from the Cat. No. 5538-4 or Cat. No. 55384R Adaptatone Signal Actuator. See page 4-40. Agency Approvals • UL Listed • cUL (24AQ, 24N5 & 24Y6 models) • CE Marked (24Y6 AC only & 24AQ models) Specifications • Heavy duty zinc cast construction 4-28 Fax-on-Demand # 1607 Cat. No. 5540M-24AQ 5540M-24N5 5540M-120N5 5540M-24Y6 5540M-120Y6 Volts 24V DC 24V AC 50/60 Hz 120V AC 50/60 Hz 120V AC 50/60 Hz 240V AC 50/60 Hz 125V DC 250V DC calling for high decibel output and microprocessor reliability combined with simultaneous signal delivery over all speakers included in the system. Typical applications include: emergency warning systems, plant evacuation alarms, security intrusion sirens, process monitoring, shift startand-dismissal horns, and paging signals. Input Card Activation Voltage Signal Off Standby Current (Amps) Signal On Operating Current (Amps) 24VDC 0.10 0.10 0.10 0.10 0.10 0.10 0.10 0.02 0.64 1.22 0.23 0.23 0.28 0.15 0.15 0.08 24VDC 120VAC 24VDC 120VAC © 2000 EDWARDS CHESHIRE, CT 06410 www.edwards-signals.com *PLC COMPATIBILITY This device may be operated by PLCs that match the input load requirements of this signal. Be sure to match the input load characteristics of the signal with the output chatacteristics of the PLC before connecting. Signal Input Load Characteristics PLC output to meet following product input parameters Max. off state leakage current (mA) Continuous on current (mA) Surge (inrush/duration) (Amps/milliSeconds) 24V DC only 25 650 25/.024 5540M-*N5 120V 50/60 hz 25 290 2.82/4 24VDC Input Board Circuit 5V DC to 24V DC (each input) 2 6 — 120VAC Input Board Circuit 120VAC 50/60 Hz (each input) 5 13 — 5540M-24AQ Electronic Signals Operating voltage (Volts) Cat. No. * = Input board designation 24 or 120 Percussive pairs of 700 and 570 Hz tones, each damped to zero 98 Warble 575 and 770 Hz alternately, 87 ms each 104 Siren 600-1250 Hz up and down sweep in 8 Sec. 110 Stutter Percussive 470 Hz, 83 ms on, 109 ms off 99 Slow Whoop 600-1250 Hz upward sweep n 4 seconds 110 Beep 470 Hz, 0.55 seconds on, 0.55 seconds off 102 Chime 1 700 Hz percussive repeat at 1 Hz 98 Fast Whoop 600-1250 Hz upward sweep in 1 second 110 Hi/Lo 780 to 600 Hz alternately, 0.52 seconds each 105 Rapid Siren 600-1250 Hz up and down sweep in 0.25 Sec. 107 Yeow 1250-600 Hz downward sweep in 1.6 seconds and repeat 110 Horn 470 Hz continuous 102 370 Hz continuous 102 Dual Tone 450-500 Hz, 0.4 to 0.5 second cycle 103 3 Pulse Air Horn 370 Hz, 3-0.5 second pulses separated by 0.5 seconds followed by a 1.5 second delay and repeat 107 3 Pulse Dual Tone 450-500 Hz, 0.4 to 0.5 second cycle, 3-0.5 second pulses separated by 0.5 seconds followed by a 1.5 second delay and repeat 105 3 Pulse Chime 2 575 Hz, 3-0.5 second pulses separated by 0.5 seconds followed by a 1.5 second delay and repeat 95 Phasor 416-625 Hz up and down sweep in 13ms 102 Telephone 570 and 770 Hz alternately 50ms. each for 1.2 sec., 1.5s delay 103 Staircase 440-2000 Hz up and down steps, 750ms 107 3 Tone Alert 463, 641,and 869 Hz, 200ms each 1 sec delay 106 Presignal Chime 470 Hz percussive repeat at 1.5 Hz 95 NFPA Whoop 422-775 Hz upward sweep 850 ms each, 1 second delay and repeat 104 Westminster Two measures 411, 520, 407, 312 Hz 98 Three Blind Mice Four Measures, 787, 714, 625, 952, 333 Hz 101 † Ratings taken in an anechoic chamber with signal volume control set at maximum and measurements made on an "A" weighted scale with peak hold. 4-29 Fax-on-Demand # 1607 Appendix © 2000 EDWARDS CHESHIRE, CT 06410 www.edwards-signals.com Telephone Signals & Accessories 107 ADA/Hospital Signaling Devices 96 470 Hz, 3 0.5 second pulses separated by 0.5 seconds followed by a 1.5 second delay and repeat Clocks 575 Hz percussive repeat at 1 Hz. 3 Pulse Horn Fire Alarm Equipment Chime 2 Push Buttons Contactors Transformers Door Devices Air Horn Electric Chimes The Adaptatone Millennium signals have priority capability. The programmed tones operate on a pyramid-type priority system. The tone programmed on switch 1 overrides the tones programmed on switches 2, 3, and 4. The tone on switch 2 overrides the tones programmed on switches 3 and 4. Likewise, the tone on switch 3 overrides the tone programmed on switch 4. The tone programmed on switch 4 has the lowest priority and cannot override any other programmed tone. Ding-Dong Outdoor Warning Signals Priority Tone Operation dB Ratings at 10 Ft.† Volume Description Message Centers & Annunciators Programming the Adaptatone Signal for the tone or tones selected is accomplished through setting the switches located in the signal base. A convenient tone selection chart is provided in the cover of each unit. In some cases the signaling task will dictate the tones required. For example, if a paging function is to be performed one of the unique percussive tones (Chime1 or Chime 2) may be most suitable. Local regulations or standards may require specific tones such as siren, horn, hi-lo. In some cases varying ambient noise may necessitate on-site evaluation of all available tones to select the most suitable tone. On-site volume control is also available by adjusting the conveniently located volume control in the base. Tone Horns & Sirens Tone Chart Bells & Buzzers Programmable Tone Selection