Edwards® 5540M Adaptatone® Millennium Central Tone Generator

advertisement
Process
Control
Signals
Hazardous,
NEMA &
IP Definitions
Visual
Signals
Electronic
Signals
Edwards® 5540M
Adaptatone® Millennium
Central Tone Generator
PLC Compatible*
Features
• PLC compatible - No external relays
required
• Stand-alone. 27 tone capability - No
additional tone modules needed
• Four 3 pulse temporal tones
• New "soft" tones
• Four Input, Four Output
• Corrosion resistant electrostatic
heat flowed epoxy finish
• Captive Components
• Centralized programmable tone
selection
• System-wide priority tone selection
Description
• Models available for 24V DC/AC 50/
60 Hz, 120V AC 50/60 Hz, 120V to
240V AC and 125 to 250V DC
• 24V DC battery backup terminals
provided
• Short Circuit protected
Installation
System components are designed for
either 1/2" (13mm) conduit or surface mounting. See Adaptatone Signaling Installation, pages 4-43 & 4-44.
Applications
Adaptatone Signaling Systems are
designed for industrial applications
The Edwards 5540M Millennium Central Tone Generator has been designed for applications where simultaneous signaling of a high decibel,
heavy duty signal is required. The Millennium Central Tone Generator produces the 27 standard Adaptatone
sounds. The tone generator assures a
synchronous signaling sound from all
remote speakers. The four tones
may be activated from field-wired,
normally open contacts, or a 24VDC
or 120VAC external voltage source
such as an output of a PLC. The tones
may be selected by setting miniature
dip switches within the unit. The programmed tones operate on a pyramid-type priority system. Normally
open contacts can be obtained from
the Cat. No. 5538-4 or Cat. No. 55384R Adaptatone Signal Actuator. See
page 4-40.
Agency Approvals
• UL Listed
• cUL (24AQ, 24N5 & 24Y6 models)
• CE Marked (24Y6 AC only & 24AQ
models)
Specifications
• Heavy duty zinc cast construction
4-28
Fax-on-Demand # 1607
Cat. No.
5540M-24AQ
5540M-24N5
5540M-120N5
5540M-24Y6
5540M-120Y6
Volts
24V DC
24V AC 50/60 Hz
120V AC 50/60 Hz
120V AC 50/60 Hz
240V AC 50/60 Hz
125V DC
250V DC
calling for high decibel output and
microprocessor reliability combined
with simultaneous signal delivery
over all speakers included in the system. Typical applications include:
emergency warning systems, plant
evacuation alarms, security intrusion
sirens, process monitoring, shift startand-dismissal horns, and paging signals.
Input
Card
Activation
Voltage
Signal Off
Standby
Current
(Amps)
Signal On
Operating
Current
(Amps)
24VDC
0.10
0.10
0.10
0.10
0.10
0.10
0.10
0.02
0.64
1.22
0.23
0.23
0.28
0.15
0.15
0.08
24VDC
120VAC
24VDC
120VAC
© 2000 EDWARDS
CHESHIRE, CT 06410
www.edwards-signals.com
*PLC COMPATIBILITY
This device may be operated by PLCs that match the input load requirements of this signal. Be sure to match the
input load characteristics of the signal with the output chatacteristics of the PLC before connecting.
Signal Input Load Characteristics
PLC output to meet following product input parameters
Max. off state
leakage current (mA)
Continuous on
current (mA)
Surge (inrush/duration)
(Amps/milliSeconds)
24V DC only
25
650
25/.024
5540M-*N5
120V 50/60 hz
25
290
2.82/4
24VDC Input
Board Circuit
5V DC to 24V DC
(each input)
2
6
—
120VAC Input
Board Circuit
120VAC 50/60 Hz
(each input)
5
13
—
5540M-24AQ
Electronic
Signals
Operating voltage
(Volts)
Cat. No.
* = Input board designation 24 or 120
Percussive pairs of 700 and 570 Hz tones, each damped to zero
98
Warble
575 and 770 Hz alternately, 87 ms each
104
Siren
600-1250 Hz up and down sweep in 8 Sec.
110
Stutter
Percussive 470 Hz, 83 ms on, 109 ms off
99
Slow Whoop
600-1250 Hz upward sweep n 4 seconds
110
Beep
470 Hz, 0.55 seconds on, 0.55 seconds off
102
Chime 1
700 Hz percussive repeat at 1 Hz
98
Fast Whoop
600-1250 Hz upward sweep in 1 second
110
Hi/Lo
780 to 600 Hz alternately, 0.52 seconds each
105
Rapid Siren
600-1250 Hz up and down sweep in 0.25 Sec.
107
Yeow
1250-600 Hz downward sweep in 1.6 seconds and repeat
110
Horn
470 Hz continuous
102
370 Hz continuous
102
Dual Tone
450-500 Hz, 0.4 to 0.5 second cycle
103
3 Pulse
Air Horn
370 Hz, 3-0.5 second pulses separated by 0.5 seconds
followed by a 1.5 second delay and repeat
107
3 Pulse
Dual Tone
450-500 Hz, 0.4 to 0.5 second cycle, 3-0.5 second pulses
separated by 0.5 seconds followed by a 1.5 second
delay and repeat
105
3 Pulse
Chime 2
575 Hz, 3-0.5 second pulses separated by 0.5 seconds
followed by a 1.5 second delay and repeat
95
Phasor
416-625 Hz up and down sweep in 13ms
102
Telephone
570 and 770 Hz alternately 50ms. each for
1.2 sec., 1.5s delay
103
Staircase
440-2000 Hz up and down steps, 750ms
107
3 Tone Alert
463, 641,and 869 Hz, 200ms each 1 sec delay
106
Presignal Chime
470 Hz percussive repeat at 1.5 Hz
95
NFPA Whoop
422-775 Hz upward sweep 850 ms each,
1 second delay and repeat
104
Westminster
Two measures 411, 520, 407, 312 Hz
98
Three Blind
Mice
Four Measures, 787, 714, 625, 952, 333 Hz
101
†
Ratings taken in an anechoic chamber with signal volume control set at maximum and measurements
made on an "A" weighted scale with peak hold.
4-29
Fax-on-Demand # 1607
Appendix
© 2000 EDWARDS
CHESHIRE, CT 06410
www.edwards-signals.com
Telephone
Signals &
Accessories
107
ADA/Hospital
Signaling
Devices
96
470 Hz, 3 0.5 second pulses separated
by 0.5 seconds followed by a 1.5 second delay and repeat
Clocks
575 Hz percussive repeat at 1 Hz.
3 Pulse Horn
Fire Alarm
Equipment
Chime 2
Push Buttons
Contactors Transformers
Door Devices
Air Horn
Electric
Chimes
The Adaptatone Millennium signals
have priority capability. The programmed tones operate on a pyramid-type priority system. The tone
programmed on switch 1 overrides
the tones programmed on switches
2, 3, and 4. The tone on switch 2
overrides the tones programmed on
switches 3 and 4. Likewise, the tone
on switch 3 overrides the tone programmed on switch 4. The tone programmed on switch 4 has the lowest
priority and cannot override any
other programmed tone.
Ding-Dong
Outdoor
Warning
Signals
Priority Tone Operation
dB Ratings at 10 Ft.†
Volume
Description
Message
Centers &
Annunciators
Programming the Adaptatone Signal
for the tone or tones selected is accomplished through setting the
switches located in the signal base. A
convenient tone selection chart is
provided in the cover of each unit. In
some cases the signaling task will dictate the tones required. For example,
if a paging function is to be performed one of the unique percussive
tones (Chime1 or Chime 2) may be
most suitable. Local regulations or
standards may require specific tones
such as siren, horn, hi-lo. In some
cases varying ambient noise may necessitate on-site evaluation of all
available tones to select the most
suitable tone. On-site volume control
is also available by adjusting the conveniently located volume control in
the base.
Tone
Horns &
Sirens
Tone Chart
Bells &
Buzzers
Programmable Tone
Selection
Download