The WitLink-2000® is the first radio system to incorporate front-loadable plug-ins to support diversified network
requirements. The WitLink-2000® feature of auto-detecting the Plug-In type allows the end-users to seamlessly
adapt to existing network requirements. Software-controlled "reduced capacity" utilizes Spectrum-on-Demand.
WitLink-2000® may scale from low capacity/low spectrum (such as 4*DS1/E1) to medium capacity / larger spectrum
(such as DS3/E3) without the need of existing hardware modification. Furthermore, these changes are field upgradeable.
The Ethernet 10/100Base-T interface plug-in supports wireless bridge implementations. These implementations are ideally
suited for Service Providers (ISP’s video-on-demand, MTU’s) and private networks. This plug-ins features two
10/100Base-T ports (Full Duplex) + 4*DS1 (E1) ports. The plug-Ins supports full transparent bridging. The PDH Plug-Ins
may be used up to a maximum capacity of DS3+4*DS1 (E3+1E1).
Modular plug-in interfaces, 6Mbps to 52 Mbps
Wireless Bridge – 2*10/100Base-T+4*DS1
Wireless Bridge – 2*10/100Base-T+4*E1
PDH – DS3+16*DS1, E3+16*E1, 4*E1/8*E1
Common IDU Specifications
IDU to ODU Connection
Number of cables
Type
Impedance
Recommended Cable
Maximum distance
IDU Connector type
Modem
Modulation type
Forward error correction
Environmental
Temperature (operation)
Relative humidity
Power Requirements
DC source
DC consumption
Mechanical
Dimensions
Weight
Standard Interfaces
Auxiliary data channel
Relay alarm outputs & external inputs
Touch keys and display interface
Network management
1+1 redundancy
Standards
Safety
EMC/EMI
Single Coaxial Cable
RG-8
50 Ohms unbalanced
Belden 9913 (RG-8) or equivalent
Up to 300m (1000ft)
"N" type Female connector
4FSK
Reed Solomon Code (correction of up to 20 bytes out of 255 bytes frame)
-5ºC to +45ºC
95% at 40ºC
22 to 60Vdc, polarity insensitive
20 Watt
1.75" (1U) x19" x12" (HxWxD) (fits standard 19" equipment rack)
10 lbs, 4.6 kg
EIA RS232 data in port; shielded RJ45 / Optional EOW service channel
D- type, 25 pin, female; 5 relays floating from “C” relay; 4 floating inputs
5 touch keys & 16x2 character LCD - standard feature
10Base- T Ethernet management port: shielded RJ45
NMS- IN port: RS232 SNMP, shielded RJ45
110 pin, female
CE mark EN60950 (ETSI); NRTL ANSI/ UL1950 (FCC)
EN 300 386-2 (ETSI), EN 300 385 (ETSI); FCC Part 15
WitLink-2000 Technical Specifications Rev-02
Outdoor Unit (ODU) and Antennas
The WitLink-2000® flexible ODU/antenna combination is available
in all frequencies within 7~38GHz range, with ETSI and FCC
approved versions. The radio frequency components of the ODU
are contained within a hermetically-sealed enclosure. The ODU
may be press fitted onto the antenna and can be mounted on a mast,
tower or rooftop. This flexible design allows the ODU to be
disconnected from the antenna without affecting antenna alignment,
and directly mounted to the antenna without the need for use of any
waveguides or adaptors. One coaxial cable is used to connect the
ODU to the IDU. Power is provided to the ODU via this single cable.
The compact, aesthetic WitLink-2000® ODU is capacity independent as well, resulting in quicker deployment
and redeployment, simplified logistics and reduced spare part requirements.
Common ODU Specifications
General
Frequency stability
Frequency channel selection
Environmental
Temperature (operation)
Relative humidity
Altitude
Power Requirements
DC source
DC consumption
Mechanical
Dimensions
Weight
Standards
Environmental
Safety
±5ppm
Software-controlled
-33ºC to +55ºC
All weather protection (up to 100%)
Up to 15,000 feet AMSL (4,500 m)
22 to 60Vdc, supplied by the IDU
23 Watt / 32 Watt for high power
9.05" x 6.9" (23x17.5 cm) (DxH)
9.6 lbs, 4.9 kg
ETS-300-019-2-4
CE mark EN60950 (ETSI); NRTL ANSI/ UL1950 (FCC)
Antenna Specifications – (Direct Mount or Indirect Mount via Wave guide)
Type
Parabolic, high performance, all frequencies
Diameters
1'(30cm), 1.5’(45cm), 2'(60cm), 3'(90cm), 4'(120cm), 6'(180cm)
7/8/13/15GHz (2, 3, 4, 6 feet) 18/23GHz (1, 1.5, 2, 3, 4 feet)
Diameter per Frequency
26GHz(1, 1.5, 2, 3 feet) 38GHz (1, 1.5, 2 feet)
Polarization
Horizontal or vertical
WitLink-2000 Technical Specifications Rev-02
System Specification (Table I)
System
Parameters
7/8 GHz
ETSI
13 GHz
ETSI
15 GHz
ETSI
18 GHz
FCC & ETSI
General
Operating at
Frequency
Tx / Rx
Spacing
RF connector
Transmitter
Tx output
Power
Output power
Control range
ITU
emissions
designators
per capacity
7.125 – 8.5 GHz
12.75 – 13.25 GHz
14.40 – 15.35 GHz
17.70 – 19.70 GHz
119,154,161,311 MHz
266 MHz
315, 420, 728 MHz
FCC 1560 MHz
ETSI 1010 MHz
Waveguide Flange
(WR-112)
Waveguide Flange
(WR-62)
Waveguide Flange
(WR-62)
Waveguide Flange
(WR-42)
+27dB
+25dB
+25dB
Software Controlled; Mute – 45 dBm
+35 dBm
+35 dBm
+37 dBm
7M00F7W
14M0F7W
28M0F7W
56M0F7W
7M00F7W
14M0F7W
28M0F7W
56M0F7W
7M00F7W
14M0F7W
28M0F7W
56M0F7W
+20dB
+24dBm for High power
+30 dBm
FCC
ETSI
5M50F7W
13M8F7W
10M0F7W
27M5F7W
20M0F7W
55M5F7W
40M0F7W
Receiver
FCC
Sensitivity
-6
@10 BER
4*E1
8*E1
16*E1
E3
E3+E1
4*E1 -81 dBm
8*E1 -78 dBm
16*E1 -75 dBm
E3
-75 dBm
E3+E1 -73 dBm
-82 dBm
-79 dBm
-77 dBm
-77 dBm
-75 dBm
Max input
signal level
System Gain
4*E1 -81 dBm
8*E1 -78 dBm
16*E1 -75 dBm
E3
-75 dBm
E3+E1 -73 dBm
8*DS1
16*DS1
DS3
DS3+2*DS1
DS3+4*DS1
-79dBm
-76dBm
-73dBm
-73dBm
-72dBm
ETSI
8*E1
16*E1
E3
E3+E1
-77dBm
-74dBm
-74dBm
-72dBm
-10 dBm @ 10-3 BER
FCC
4*E1
8*E1
16*E1
E3
E3+E1
Standards
RF channel
Arrangement
Complies
with
109 dB
106 dB
104 dB
104 dB
102 dB
4*E1
8*E1
16*E1
E3
E3+E1
106 dB
103 dB
100 dB
100 dB
98 dB
4*E1 106 dB
8*E1 103 dB
16*E1 100 dB
E3
100 dB
E3+E1 98 dB
8*DS1
16*DS1
DS3
DS3+2*DS1
DS3+4*DS1
99 dB
96 dB
93 dB
93 dB
92 dB
ETSI
8*E1
16*E1
E3
E3+E1
97 dB
94 dB
94 dB
92 dB
ITU-R Rec.F.385-6
ITU-R Rec.F.386-6
ITU-R Rec.F.497-6
ITU-R Rec.F.636-3
ITU-R Rec.F.595-6
ETSI EN 301 216V1.2.1
ETSI EN 301 128
ETSI EN 301 128
ETSI EN 301 751
ETSI EN 301 128
FCC Part
101
WitLink-2000 Technical Specifications Rev-02
System Specification (Table II)
System
Parameters
General
Operating at
frequency
Tx / Rx
Spacing
RF connector
Transmitter
Tx output
power
Output power
Control range
ITU
emissions
designators
per capacity
23 GHz
FCC & ETSI
26 GHz
ETSI
21.20 – 23.60 GHz
24.50 – 26.50 GHz
FCC 1200 MHz
ETSI 1008, 1232 MHz
Waveguide Flange
(WR-42)
+20 dBm
Waveguide Flange
(WR-42)
FCC 38.60 – 40.00 GHz
ETSI 37.00 – 39.50 GHz
FCC 700 MHz
ETSI 1200 MHz
Waveguide Flange
(WR-28)
+20 dBm
+30 dB
ETSI
7M00F7W
14M0F7W
28M0F7W
56M0F7W
FCC
7M00F7W
12M5F7W
25M0F7W
50M0F7W
1008 MHz
38 GHz
FCC & ETSI
Software Controlled; Mute – 45 dBm
+30 dB
7M00F7W
14M0F7W
28M0F7W
56M0F7W
+17 dBm
+27 dB
FCC
ETSI
7M00F7W
7M00F7W
12M5F7W
14M0F7W
25M0F7W
28M0F7W
50M0F7W
56M0F7W
Receiver
FCC
FCC
Sensitivity
-6
@10 BER
4*DS1
8*DS1
16*DS1
DS3
DS3+2*DS1
DS3+4*DS1
-81 dBm
-79 dBm
-76 dBm
-74 dBm
-74 dBm
-72 dBm
ETSI
4*E1
8*E1
16*E1
E3
E3+E1
-81 dBm
-78 dBm
-75 dBm
-75 dBm
-73 dBm
Max input
signal level
System Gain
4*E1
8*E1
16*E1
E3
E3+E1
-81 dBm
-78 dBm
-75 dBm
-75 dBm
-73dBm
4*DS1
8*DS1
16*DS1
DS3
DS3+2*DS1
DS3+4*DS1
ETSI
4*E1
8*E1
16*E1
E3
E3+E1
FCC
FCC
ETSI
4*E1 101 dB
8*E1 98 dB
16*E1 95 dB
E3
95 dB
E3+E1 93 dB
Arrangement
Complies
with
-78 dBm
-75 dBm
-72 dBm
-72 dBm
-71 dBm
-10 dBm @ 10-3 BER
4*DS1
101 dB
8*DS1
99 dB
16*DS1
96 dB
DS3
94 dB
DS3+2*DS1 94 dB
DS3+4*DS1 92 dB
Standards
RF channel
-78 dBm
-75 dBm
-72 dBm
-70 dBm
-70 dBm
-69 dBm
4*E1 95 dB
8*E1 95 dB
16*E1 98 dB
E3
101 dB
E3+E1 93 dB
4*DS1
8*DS1
16*DS1
DS3
DS3+2*DS1
DS3+4*DS1
95 dB
92 dB
89 dB
87 dB
87 dB
86 dB
ETSI
4*E1
8*E1
16*E1
E3
E3+E1
96 dB
93 dB
90 dB
90 dB
89 dB
ITU-R Rec.F.637-3
ITU-R Rec.F.748-3
ITU-R Rec.F.749-1
ETSI EN 300 198
FCC Part
101
ETSI EN 300 431
ETSI EN 301 390
ETSI EN 300 751
ETSI EN 300 197
ETSI EN 301 390
ETSI EN 301 751
FCC Part
101
WitLink-2000 Technical Specifications Rev-02
Interface Plug-ins
Component
Technical Parameters
Two 10/100Base-T+4DS1(4E1)
PIN-42042 (PIN-52042)
DS3 +16DS1 (E3+16E1)
PIN-12161 (PIN-22161)
4E1/8E1
PIN-22040 (PIN-22080)
Digital Interface
IEEE 802.3,802.3u standard
Compliance: DS1(E1) per
ITU-T Rec.G.703
DS1(E1)&DS3(E3) per
ITU-T Rec.G.703
E1 per ITU-T Rec.G.703
Digital Input/Output
Connector
10/100Base-T-shielded RJ45,
100Ω; DS1(E1)-shielded
RJ48, 100Ω (120Ω)
Digital Line Code
DS1-AMI / B8ZS
E1-HDB3
Digital Capacity
Configurable
Capacities
Channel Spacing
23/38GHz FCC
Channel Spacing
18GHz FCC
Channel Spacing
13/15/23/26/38GHz
ETSI
Channel Spacing
18GHz ETSI
2x10/100Base-T ports+4DS1
(4E1) wayside channels
2x10/100Base-T+4DS1
2x10/100Base-T+1,2,4E1
12.5MHz, 25MHz, 50MHz
10MHz, 20MHz, 40MHz
DS1(E1)-shielded RJ48,
100Ω (120Ω) balanced,
DS3(E3) – Coax BNC,
75Ω unbalanced
DS1-AMI/B8ZS, DS3-B3ZS
E1- HDB3, E3-HDB3
Up to 16DS1 (16E1) or
DS3+4DS1 (E3+1E1)
4/8/16DS1, DS3, DS3+4DS1
4/8/16E1, E3, E3+1E1
7.5MHz, 12.5MHz, 25MHz
50MHz
7.5MHz, 10MHz, 20MHz
40MHz
E1-shielded RJ48, 120Ω
E1-HDB3
Up to 4 or 8E1
4 / 8E1
14MHz, 28MHz, 56MHz
7MHz, 14MHz, 28MHz
7MHz, 14MHz
13.75MHz, 27.5MHz, 55MHz
7MHz, 13.75MHz, 27.5MHz
13.75MHz
Additional LAN Specifications
Available throughput at
100Mbs full duplex
data input rates.
With flow control
(Channel spacing @
FEC10)
LAN sensitivity @
FER
(Frame error rate)
LED Indicators
ETSI PIN-52042
Ethernet only
Ethernet+4E1
14 MHz – 18 Mbps 14 MHz – 10 Mbps
28 MHz – 36 Mbps 28 MHz – 28 Mbps
56 MHz – 48 Mbps 56 MHz – 40 Mbps
FCC PIN-42042
Ethernet only
Ethernet+4DS1
12.5 MHz – 12 Mbps 12.5 MHz – 6 Mbps
25 MHz – 24 Mbps 25 MHz – 18 Mbps
50 MHz – 48 Mbps 50 MHz – 42 Mbps
*Note: Each E1 used drops 2Mb/s from the maximum available Ethernet throughput*
Frame error rate < 5x10-4 at channel spacing 14/28/56 MHz According to FER/BER equivalence
table: ETSI EN 301 785 (Sensitivity @10-6 BER values are specified in tables I and II)
Full / Half duplex, Port enabled / disabled, Port activity, speed and collisions
WitLink-2000 Technical Specifications Rev-02
1+1 Redundancy Kits for 1 and 2 Antenna Configuration
WitLink-2000® supports Hot Standby redundancy, with no single points of failure.
Redundancy is achieved by routing the tributaries and interfaces input lines via a passive Redundant Switching Unit (RSU).
The switching logic is performed in the RSU. Switching decisions are made according to Hardware and Software failure
indications (link status, RSL, BER, etc.) generated by each terminal. A defective IDU or ODU can be easily removed
Without affecting the operating link and replaced with no down time. The RSU is backup powered by either IDU.
The RDK (Redundancy Kit) is used to complete a protected WitLink-2000® terminal.
The RDK-X2161-C-13-38-1ANT kit supports one antenna configuration, for all frequencies, with asymmetric split
RF Coupler. The kit includes the RSU, Redundant Plug-in (RPI-X2161, E3+16E1 or DS3+16DS1) and the upper
and lower interconnection assemblies used to interconnect the RSU with the two IDUs. The kit includes the ODU
Protection Assembly (OPA), which includes the ODU-1+1 Mount, one RF directional coupler and one rigid waveguide.
Not included (per terminal side) are the 2 IDUs and 2 Plug-ins, 2 ODUs, 1 Antenna + mount, 2 coaxial cables and one
flexible waveguide used to interconnect between the OPA and the selected antenna.
The RDK-X2161-2ANT kit supports two antenna configurations for all frequencies. The kit includes the RSU,
Redundant Plug-in (RPI-X2161, E3+16E1 or DS3+16DS1) and the Upper and Lower interconnection assemblies used to
interconnect the RSU with the two IDUs. Each of the two ODUs are individually connected to an antenna. It is possible to
mount the ODUs directly to the antennas, or use a flexible waveguide (Requires Mount-1+0 to mount the ODU on the pole).
Not included (per terminal side) are the 2 IDUs and 2 Plug-ins, 2 ODUs,
2 Antennas + mounts, and 2 coaxial cables.
Common Redundancy Kit Specification
System characteristics
RDK-X2161-C-13-38-1ANT
RDK-X2161-2ANT
Link Management
IDU LCD Front-panel, RSU front panel, WitView-EM
Management connections
10 Base-T Ethernet, SLIP (RJ45 connectors type)
Switching time
100mSec typical
Dual ODU/Single antenna
Dual ODU/Dual antennas
Mechanical configuration
Mounted on Witcom’s antennas or
ODUs
Mounted on OPA
on mount-1+0 and flexible waveguide
FCC & ETSI, all frequencies,
RF coupler
Asymmetric split 1.8dB main,
N/A
6.5dB standby
Operation modes
Hot standby
Hot standby, frequency diversity
WitLink-2000 Technical Specifications Rev-02
WitView-EM: SNMP Element Manager
WitView-EM™ is an intuitive, pro-active element network management system with enhanced diagnostic
and performance monitoring tools. It provides open, reliable and user-friendly GUI-based SNMP management.
Based on a standard SNMP platform, WitView-EM™ can be integrated with HP OpenView™ or used as a stand-alone
management application. WitView-EM™ supports local and remote terminal configuration, status/alarm reporting,
traps, statistics (per G.826) and diagnostics. WitView-EM™ provides the SNMP tool to proactively manage
all links from a single operator console, over IP. WitView-EM™ runs on Microsoft Windows® 95/98/2000 or
NT stations. The embedded SNMP agent in each WitLink-2000® IDU implements standard IEFT/RFC MIB II Ethernet,
E1/DS1, E3/DS3 MIBs, and private WitLink-2000® MIB extensions that enable remote monitoring and control
of the entire link or complete network from a single point. An incorporated RIP Protocol enables simultaneous
management of all radio links. All radio links can be easily in-band or out-of-band controlled from the management
station. All system parameters are software configurable.
Trivial File Transfer Protocol (TFTP) enables remote software upgrading.
WitLink-2000 Technical Specifications Rev-02