DATE: PROJECT: Vertical Adjustment Plastering Compound Vent Slot Lamp (By Others) Lampholder Alzak Cone Support Plaster Anchor Screw Torsion Spring Turnbuckle Plaster Anchor Housing K7411FM TYPE: Flush Mount Low Voltage Directional AR111 or PAR-36 Lamps 4 1/8" Round Conoid Aperture Aperture Drywall Screw Pan Representative illustration. Flush Mount Kurt Versen’s flush mount fixtures eliminate overlapping flanges and lock into the ceiling for a unique, finished appearance. A clean, uncluttered ceiling emphasizes the attention to detail, enhancing the impact of the interior environment. It is a factory installed option with a proven installation technique. Optics and Applications The parabolic cone provides shielding and brightness control in directional applications. Use also for vertical downlighting in sloped ceilings. Ideal for highlighting merchandise, art objects and other points of interest. Design Features The lamp assembly rotates 360° and tilts 40°. Positive locking maintains focusing during relamping. The cone is retained by a torsion spring and rotates with the lamp to maintain position. The lamp can be aimed and locked, then fine-tuned with a threaded turnbuckle. Flush mount design resists cracking and chipping by mechanically fastening fixture to drywall. To simplify installation, three adjustment mechanisms adapt the fixture to ceiling conditions. Adjustable mounting rails fit different support systems and accommodate ceiling thicknesses from 3/8" to 7/8". Maximum extension is 26". Top or bottom service. Finish A specular clear Alzak cone is standard. Optional colors and Softglow® finishes are available. Structural parts are painted optical matte black to suppress light leaks. Aperture Pan Drywall Screw Alzak Cone Plaster Shield Plaster Anchor Support Rail Dimensions and Lamps General Fixtures are pre-wired and thermally protected, UL and C-UL listed for damp location and eight wire 75°C branch circuit wiring. All products are union made. Designed and manufactured in the USA. Warranty 5 Year Warranty. See www.kurtversen.com for details or select hyperlink. D A B C Number A Depth B C Aperture Width D Length Lamps K7411FM 7 3/4" 197mm 4 1/8" 105mm 18 3/8" 467mm 25-75W AR111 25-50W PAR-36 Rev1 Date 2/16/2016 Transformer Each fixture has a magnetic transformer with 120V primary as standard. A voltage switch provides secondary output of 12V or 5.5V as required. The transformer is rated 180° C Class H with a built-in 150° thermal reset. It is accessible through the aperture. 19 3/8" 492mm Accessories B Black cone. WHT White complete cone. G Gold cone. WT White cone return. W Wheat cone. LL Linear spread lens. Y Pewter cone. SO Solite lens. CP Chicago Plenum UV Ultraviolet filter. STC Straight top cone,restricts aiming angle to 10°. FR Frosted lens. Example: LLFR for linear lens frosted. ET1 Electronic transformer 120V to 12V. ET2 Electronic transformer 277V to 12V. FMW Flush mount wood, contact the factory. V277 277 volt primary magnetic transformer. WRL Wattage restriction label, specify wattage. S Softglow ® add S to color, e.g.SC Softglow® clear. ©2016 Kurt Versen, a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Kurt Versen reserves the right to change specifications without notice. One Paragon Drive, Suite 157, Montvale, NJ 07645 / Tel 201.664.8200 / Website www.kurtversen.com F K7411FM Footcandle Values Distance Nadir Lamps K7411FM 50W AR-111 FL K7411FM 75W AR-111 FL Distance FC 104 FC K7411FM 35W AR-111 SSP 183 73 2' 40 15' 10° 79 75° 500 65° 750 55° 1000 45° 1250 1500 35° 1750 2000 2250 2500 5° 15° 25° Nadir 5' 4' 5° 20' 10 85° 75° 8400 65° 12600 55° 16800 21000 45° 29400 35° 25200 33600 37800 5° 15° 42000 5° 15° 25° 75° 8400 65° 12600 16800 21000 45° 29400 35° 25200 33600 42000 5° 15° 25° 5° 25' 4 8' 7 6 8' 10° 10 Nadir 3' 6 7' 28 3' 5 10 7' 7' 2 4' 0 9' 46 13 4' 4 9' 20 4' 4' Candelas ° 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 85° 2800 75° 5600 65° 8400 11200 14000 45° 19600 35° 16800 22400 25200 28000 5° 15° 25° K7411FM 35W AR-111 SSP K7411FM 50W AR-111 SSP K7411FM 75W AR-111 SP Eff. 87% S/M .10 Eff. 88% S/M .10 Eff. 89% S/M .14 50W 850* 2590 2252 1914 1101 514 210 11 0 0 0 0 0 0 0 0 0 0 0 0 3 6 ° 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 50W 41110 981 89 10 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 42011 6107 1947 135 14 0 0 0 0 0 0 0 0 0 0 0 0 0 0 850* 15° 5 7' 7' 5° 30' 2 11' 4 11' 10° FC Diam FC Diam 1 5' 0 9 5' 3 7 11 5' 5' 2 4 11' 11' 11' 11' Notes 1 Data with clear specular cones. 2 Colored cone multipliers vary with lamp source, beam orientation, and degree of angulation. Contact the factory for specific data. 4101 3765 3510 1764 550 222 12 0 0 0 0 0 0 0 0 0 0 0 0 Vertical Angles ° Initial Lamp Lumens * 29 1250* 35W 350* 9' 47 75W Vertical Angles ° Initial Lamp Lumens * 9' 10° 20' FC Diam FC Diam 8 16 21 3' 25° 85° 4200 5' 41 66 35° 3360 5' 26 7' 45° 2940 8 15 65 0 55° 2520 Nadir 10 3' 65° 2100 18 2 75° 1680 12 Nadir 85° 1260 37800 5' 10° K7411FM 50W AR-111 FL K7411FM 75W AR-111 FL Eff. 72% S/M .46 Eff. 76% S/M .48 4200 5' 16 15° 67 45 17 4' 34 10° FC Diam FC Diam FC 15 5' 3' Nadir 105 11 5' 15° Diam FC Diam FC FC Diam FC Diam FC 3' 8 18 10° 15' FC Diam FC Diam FC 37 3' FC 10' FC 103 840 4200 41 5' 420 3780 26 0 Candlepower Distribution 85° 3' 3' 46 250 3' 64 4 115 K7411FM 75W AR-111 SP Nadir FC Diam FC Diam 27 See note 4. 2' 5° K7411FM 50W AR-111 SSP 187 K7411FM 50W AR-111 SP 15° FC Diam FC Diam FC 164 134 Nadir Lamps 10° 5' 3 Candlepower distribution curves: solid lines show horizontal distribution at nadir, dotted lines show horizontal distribution at 25° lamp tilt. 75W 1250* 25799 10401 4098 298 49 12 0 0 0 0 0 0 0 0 0 0 0 0 0 One Paragon Drive, Suite 157, Montvale, NJ 07645 / Tel 201.664.8200 / Website www.kurtversen.com ©2016 Kurt Versen, a division of Hubbell Lighting, Inc. / K7411FM / Rev1 Date 2/12/2016 Because of continuing product improvement programs, Kurt Versen reserves the right to change specifications without notice. 4 Pattern diameters are determined from each side of nadir with 0° lamp tilt. The diameter includes both sides, so a 10° diameter represents a total 20° pattern width at the work plane. Footcandles are measured at the diameter edge. Tilting the lamp changes all data. 5 All data with lamp shields in place, if required. 6 Brightness data is omitted because readings were negligible. 7 Because of the small 41/8" aperture, wide flood lamps may lose part of their output within the fixture. 8 For PAR-36 photometric data, contact the factory.