Power Conditioning Voltage Regulators Power Conditioning Transformers & Power Distribution Units Series 700F Power Processor Series 700A Power Processor Ultra-K Isolation Transformer (10 kVA to 150 kVA Three Phase) (5 kVA to 25 kVA Single Phase) (10 kVA to 1 mVA Three Phase) (5 kVA to 25 kVA Single Phase) (15 kVA to 500 kVA Three Phase) • 7-tap, microproces- • Meets NEMA TP 1-2002 dry type distribution transformer • Front access only! All installa- tion, operation, maintenance, and testing can occur from the front of the unit — no side or rear access required. • Identical voltage regulation and power conditioning performance as the Series 700A. • Front access to all options including a regulator bypass, output distribution circuit breakers, and input / output digital meters. • Advanced monitoring options include data-logging, programmable limit alarms, a waveform scope to view the real-time waveform for voltage and current, plus power quality monitoring with event logging. • Optional communications include Ethernet TCP/IP and MODBUS TCP. Applications: Commercial, Industrial, Power Generation Plants, Refineries, Aerospace, Telecommunications, Pulp / Paper Mills, Industrial Lasers sor-controlled. • Precisely maintains correct voltage to ± 3% within one cycle, and maintains regulation during extended brownouts. • Low output impedance transformer minimizes voltage distortion and sags commonly associated with high surge currents. • Triple-shielded transformer provides a noise-free ground, attenuates voltage spikes and transients, and re-establishes the N-G bond. • Internal bypass option that “maintains system isolation and voltage transformation.” for imaging and treatment modalities, healthcare I.T., MRI suites, and patient vicinity equipment. * Harmonic transformers are excluded from the NEMA TP 1-2002 Standard. Applications: Switch Mode Power Supplies, Variable Speed Drives, Sensitive Digital Equipment in Theaters and Recording Studios Series 900/200 Power Commander (“Plus”) Output Range from 6 VDC to 1000 VDC; 40 Amps to 35,000 Amps AACD (Automatic Average Current Density) (Consult factory for model specifics.) • Adjusts DC voltage for proper • Standard and custom designs • DC voltage adjustment based (15 kVA to 150 kVA Single Phase) (15 kVA to 450 kVA Three Phase) for plating, anodizing, e-coating, motor testing, and special applications. • Conventional and modular designs; air- or water-cooled models. • Three phase input available from 208 VAC to 600 VAC, 50 Hz or 60 Hz. • Provides isolated, • Precise electrical power for critical loads. • Automatic correction of voltage deviations to ± 1% of nominal. • Adjustable output voltage. • Electronically and magnetically regulated — no moving parts, virtually no preventive maintenance required. • High fault-clearing capability. • “Plus” models include computer-grade isolation transformers. Applications: Test Laboratories, Industrial, Commercial, Distributed Control Systems (DCS), Power Generation Authorities, Regulated Bypass for Uninterruptible Power Systems, Broadcast Communications e-coating film thickness. UPS, Power Conditioning Voltage Regulators, and Power Distribution for I.T., telecom, industrial automation, and testing applications. on load current to maximize savings on power and paint consumption. • Compatible with batch or continuous conveyor processes. • “Empty tank” power savings. Industrial DC Power Supplies (Rectifiers) for electrocoating, anodizing, and other metal finishing applications. Series 50 Secondary SCR (100A to 5000A) Warranty: Consult factory for specific product warranties, start-up services, and extended coverages. UL 60601-1 (Medical) UL 924 / C-UL (Emergency Lighting) UL / C-UL 1778 (Standard UPS) UL 1012 and 1561 (Power Conditioning Transformers) Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. 5 Emergency Lighting Inverters for commercial, industrial, educational, and medical facilities. Industrial DC Power Supplies (Rectifiers) 800A Commercial Model (500 VA to 15 kVA) 800PI Industrial Model (500 VA to 25 kVA) Applications: 800A — High-End Digital Photography, Security Systems, Medical Labs 800PI — Industrial Networks, Automation Equipment, Machine Tools, PLC’s, Instrumentation Medical-Grade Power Conditioners and UPS Applications: Food Processing, Pharmaceuticals, Commercial, Industrial, Audio / Visual, Wastewater Treatment, Robotics Series 800 Power Purifier regulated, and noise-free electrical power to protect sensitive electronic equipment. • Variable range regulation increases input voltage range under lighter loads, 800PI models shown while tight output voltage is maintained. • Provides power “ride-through”, even with the loss of input voltage for up to 1 cycle. • 800PI models available in NEMA 1, 2, and 3R enclosures. Electrical Power Solutions efficiency standards. • Achieves NEMA TP 1-2002 Table 4-2 efficiencies under a K13 non-linear load at or between 35% - 50% of its rating on models 30 kVA and higher. * • All copper windings and conductors with double-sized neutral. • Removes triplen harmonic currents from the line. • Double- or triple-shielded (146 dB) for high common mode noise attenuation. • Optional Cat. B3 TVSS with output high frequency noise filter. EPS-006-0416 Controlled Power Company engineers and produces the industry’s highest quality electrical power solutions, capitalizing on over 40 years of design and manufacturing expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. From Research and Development... through Engineering, Marketing, and Sales... through Manufacturing and Shipping... through Accounting and Customer Support, Controlled Power Company is never content with the status quo in either our products or our attention to our customers. We continue to be a leader in the broad range of markets we serve, by proactively anticipating power quality trends and requirements, and listening attentively to our prospects’ and customers’ needs. Medical-Grade Power Conditioners and UPS MedPoweRx Model LT/M SuiteLITE Model SCLU (700 VA to 2.1 kVA) (600 W to 3000 W) • Battery back-up for patient • Meets the hospital-grade vicinity medical systems. • Less than 300 micro-amps leakage current to ground. • Optional specially-designed wheeled cart for portability. Applications: Mammography, Ultrasound, Fluoroscopy, Dialysis, Hospital Room PC’s, Nurse Call Stations, Fetal Monitor Carts* * Disclaimer: Product not intended for life support applications. Controlled Power Company does not accept any liability for this product being used with ventilators or any other life support systems. lighting power requirements of RF-shielded MRI suites. • Assures a highly-filtered, regulated, dimmable, DC output, and provides illumination without image interference. • Slide dimmer control with on / off switch, or optional in-suite lighting adjustment. • Compact size for easy installation, maintenance-free. Applications: MRI Suite Lighting SureImage Model 700F/M SureImage Model Ultra-K/M (75 K(i) to 225 K(i) Three Phase) • 98% efficiency, typical. • High frequency filter. • Low temperature rise (105˚F). • 146 dB common mode noise attenuation. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology (60 K(i) to 260 K(i) Three Phase) • Output line voltage regulation ± 2%, typical. • Up to 97% efficiency. • Front access enclosure. • Optional input and output metering with real-time monitoring and waveform viewing. • Optional output circuit breakers. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology, Linear Accelerator Centralized Emergency Lighting Inverters Uninterruptible Power Supplies (UPS) EON Model EL3 UltraLITE Model ELC LT Series Model ES (10 kW to 33 kW Three Phase) (600 W to 2 kW Single Phase) (700 VA to 2.1 kVA) (4500 VA to 15500 VA) • Computer-based, self-testing / • Compact, front access design, •Tower (Model LT) or • Online, double-conversion self-diagnostic emergency lighting system with data-logging and reporting (NFPA 101, 7.9.3.1.3). • Physically smaller than comparable three-phase emergency lighting inverter products, without compromising performance or serviceability. • Requires only (1) battery cabinet for 90 minutes runtime. • Only batteries with front-access terminals are used. Applications: Theaters / Concert Halls, Auditoriums, Airports, Casinos, Conference / Banquet Centers, Industrial Manufacturing, Warehouses UltraLITE Model ELU • Color, TFT, high resolution touch- (1.5 kW to 14 kW Single Phase) screen display for viewing system parameters, status, alarms, and programming of date / time values and system setpoints. • Provides complete system diagnostics and testing, including all NFPA-compliant automatic battery testing and report logging. • Performs egress lighting integrity test. Download product brochure and specifications from any product webpage: • Model SCLU • Model Ultra-K/M • Model 700F/M 2 © April 2016. Controlled Power Company. Intellistat™, Intellistat TS™, NetMinder™, and Fuzzy Ranging™ are trademarks of Controlled Power Company. • Model LTN-3R outdoor UPS with extended runtimes; NEMA 3R raintight enclosure design. • Elastomeric insulation prevents condensation and internal moisture. • Conformal coated circuit boards. • Runtimes from 30 minutes to 9.5 hours at full load, model dependent. Applications: LT, LTR, LTN — Industrial / Automated Process Controls, Point-of-Sale Computers, Instrumentation LTN-3R — Traffic Controls, Vehicle / Cargo Scanning, Solar Array Controls • Seamless transfer, online Model ELU display shown Available On: UltraLITE Model ELU: 1.5 kW – 14 kW sizes Standard On: EON Model EL3: 10 kW – 33 kW three phase sizes NetMinderTM Communications Remote (BACnet, SNMP, TCP/IP, E-Mail, MODBUS) communication of test results and system status. Provides automatic transfer between normal and emergency power for up to eight (8) individual single phase, 20 amp circuits. • Model LT/M rack-mount (Model LTR) styles available. • Line cord / receptacle or hardwired models. • Model LTN (NEMA 2) UPS with extended battery runtimes; front access style enclosure. Applications: Commercial, Industrial, Schools, Hospitals, Office Buildings, Retail Stores, Multi-Unit Dwellings Advanced Digital Monitoring The Intellistat TSTM SwitchLITE Model EZT Features And Benefits Common to Both the SureImage Models Ultra-K/M and the 700F/M • “K(i) Rated” to meet the momentary power demand of medical imaging and treatment equipment. • Significantly reduces / eliminates “artifacts” in the digital image, which enhances workflow, increases patient throughput, and contributes to lower operating costs. • Triple shielded isolation transformer provides excellent common and normal mode noise attenuation. • Low output impedance delivers < 2% load regulation from typical steady state load to intermittent power demand. featuring one of the smallest cabinet footprints in the industry. • Uninterrupted, regulated, continuous sinewave output, compatible with all existing and future lighting loads. • Timed Normally Off Bus “PLUS” option includes an adjustable soft start to accommodate the high inrush current of “normally off” emergency lights. • High-speed automatic static bypass. • Manual bypass switch. • NEMA 2 drip-proof enclosure. double-conversion system, compatible with all existing and future lighting loads. • Automatic static bypass. • Secure, internal make-before-break inverter bypass switch. • Basic and advanced Intellistat TS™ monitoring options. • System approved for 42k AIC rated source. • Online double-conversion technology. • Up to 4 hours of runtime in a front access cabinet design, with zero side or rear clearance requirements. • Color monitor with high-resolution touch-screen display. Model LTN-3R shown • Internal bypass option that “maintains system isolation and voltage transformation”. • Multiple input / output voltage configurations. • Custom-configured output distribution and receptacles. True uninterruptible power, designed for HID, incandescent, halogen, and quartz lighting applications, plus PFC electronic ballast loading up to 50% of the inverter’s rated output. Applications: LAN / WAN, Telecommunications, Industrial Controls Applications: ES, ESV — I.T. Server Rooms, Industrial Controls, and Telemetry HV Series (7.5 kVA to 25 kVA) • Integral constant voltage transformer isolates and regulates output voltage. • Internal bypass option that “maintains system isolation and voltage transformation”. • Optional “System Power Analyzer” local monitor. Applications: Windfarm Power Substations, SCADA / DCS, Extensive LAN / WAN Systems, Industrial Controls Note: “Variable Range Regulation” (using Fuzzy Ranging™ technology) broadens the input operating range of the UPS as a function of load, down to -40% of the input voltage; standard on the LT and MD Series products. Applications: Commercial, Industrial, Schools, Hospitals, Arenas, Mass Transit, Airports, Restaurants, Worship Facilities Features And Benefits Common to All Controlled Power Company LT, MD, and HV Series UPS’s • Steady, regulated output voltage to ± 3% of nominal, extends the life of protected equipment. • Built-in isolation eliminates electrical noise, and provides a “newly derived power source”. • Field-expandable power ratings, and optional extended battery runtimes. • Batteries are pre-assembled, installed, tested, and shipped within the UPS enclosure. (Excluding Model LTN-3R) • No-break, continuous power provides seamless transfer to back-up power, and prevents data loss. • Accelerated battery charger options. • Optional “NetMinder”™ UPS Management Suite software and hardware for UPS monitoring and unattended computer / network shutdown. Features And Benefits Common to All Controlled Power Company Emergency Lighting Inverters • Uninterrupted, regulated power for “normally on” lighting fixtures / exit lamps, and for “normally off” emergency lights. • Meets NFPA 101 and 111 standards. NFPA compliant as “Life Safety Equipment”. • Front access design with small footprint — front access distribution behind a lockable panel door. • UL 924 Listed as “Emergency Lighting Equipment” with standard 90 minutes; optional battery run times available. • Generator-compatible and available with 10 – 15 minutes back-up; UL 924 Listed as “Auxiliary Lighting and Power Equipment”. Download product brochure and specifications from any product webpage: • Model EL3 • Model ELC • Model ELU • Model ELN • Model ELE (1.5 kVA to 14 kVA) (3.1 kVA to 7.5 kVA) ELN (550 W to 1.5 kW Single Phase) ELE (5.3 kW to 18 kW Single Phase) time, without the need for additional cabinetry. • Choice of nominal input voltages, with conversion to the exact nominal output voltage needed, even in bypass. • Color monitor with high-resolution touch-screen display. • Full network communications options. Model ESV MD Series eLITE Models technology. • Extended battery backup • Model EZT 3 Download product brochure and specifications from any product webpage: • Model LT • Model LTN • Model LTN-3R • MD Series • HV Series • Model ES • Model LTR • Model ESV 4 Controlled Power Company engineers and produces the industry’s highest quality electrical power solutions, capitalizing on over 40 years of design and manufacturing expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. From Research and Development... through Engineering, Marketing, and Sales... through Manufacturing and Shipping... through Accounting and Customer Support, Controlled Power Company is never content with the status quo in either our products or our attention to our customers. We continue to be a leader in the broad range of markets we serve, by proactively anticipating power quality trends and requirements, and listening attentively to our prospects’ and customers’ needs. Medical-Grade Power Conditioners and UPS MedPoweRx Model LT/M SuiteLITE Model SCLU (700 VA to 2.1 kVA) (600 W to 3000 W) • Battery back-up for patient • Meets the hospital-grade vicinity medical systems. • Less than 300 micro-amps leakage current to ground. • Optional specially-designed wheeled cart for portability. Applications: Mammography, Ultrasound, Fluoroscopy, Dialysis, Hospital Room PC’s, Nurse Call Stations, Fetal Monitor Carts* * Disclaimer: Product not intended for life support applications. Controlled Power Company does not accept any liability for this product being used with ventilators or any other life support systems. lighting power requirements of RF-shielded MRI suites. • Assures a highly-filtered, regulated, dimmable, DC output, and provides illumination without image interference. • Slide dimmer control with on / off switch, or optional in-suite lighting adjustment. • Compact size for easy installation, maintenance-free. Applications: MRI Suite Lighting SureImage Model 700F/M SureImage Model Ultra-K/M (75 K(i) to 225 K(i) Three Phase) • 98% efficiency, typical. • High frequency filter. • Low temperature rise (105˚F). • 146 dB common mode noise attenuation. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology (60 K(i) to 260 K(i) Three Phase) • Output line voltage regulation ± 2%, typical. • Up to 97% efficiency. • Front access enclosure. • Optional input and output metering with real-time monitoring and waveform viewing. • Optional output circuit breakers. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology, Linear Accelerator Centralized Emergency Lighting Inverters Uninterruptible Power Supplies (UPS) EON Model EL3 UltraLITE Model ELC LT Series Model ES (10 kW to 33 kW Three Phase) (600 W to 2 kW Single Phase) (700 VA to 2.1 kVA) (4500 VA to 15500 VA) • Computer-based, self-testing / • Compact, front access design, •Tower (Model LT) or • Online, double-conversion self-diagnostic emergency lighting system with data-logging and reporting (NFPA 101, 7.9.3.1.3). • Physically smaller than comparable three-phase emergency lighting inverter products, without compromising performance or serviceability. • Requires only (1) battery cabinet for 90 minutes runtime. • Only batteries with front-access terminals are used. Applications: Theaters / Concert Halls, Auditoriums, Airports, Casinos, Conference / Banquet Centers, Industrial Manufacturing, Warehouses UltraLITE Model ELU • Color, TFT, high resolution touch- (1.5 kW to 14 kW Single Phase) screen display for viewing system parameters, status, alarms, and programming of date / time values and system setpoints. • Provides complete system diagnostics and testing, including all NFPA-compliant automatic battery testing and report logging. • Performs egress lighting integrity test. Download product brochure and specifications from any product webpage: • Model SCLU • Model Ultra-K/M • Model 700F/M 2 © April 2016. Controlled Power Company. Intellistat™, Intellistat TS™, NetMinder™, and Fuzzy Ranging™ are trademarks of Controlled Power Company. • Model LTN-3R outdoor UPS with extended runtimes; NEMA 3R raintight enclosure design. • Elastomeric insulation prevents condensation and internal moisture. • Conformal coated circuit boards. • Runtimes from 30 minutes to 9.5 hours at full load, model dependent. Applications: LT, LTR, LTN — Industrial / Automated Process Controls, Point-of-Sale Computers, Instrumentation LTN-3R — Traffic Controls, Vehicle / Cargo Scanning, Solar Array Controls • Seamless transfer, online Model ELU display shown Available On: UltraLITE Model ELU: 1.5 kW – 14 kW sizes Standard On: EON Model EL3: 10 kW – 33 kW three phase sizes NetMinderTM Communications Remote (BACnet, SNMP, TCP/IP, E-Mail, MODBUS) communication of test results and system status. Provides automatic transfer between normal and emergency power for up to eight (8) individual single phase, 20 amp circuits. • Model LT/M rack-mount (Model LTR) styles available. • Line cord / receptacle or hardwired models. • Model LTN (NEMA 2) UPS with extended battery runtimes; front access style enclosure. Applications: Commercial, Industrial, Schools, Hospitals, Office Buildings, Retail Stores, Multi-Unit Dwellings Advanced Digital Monitoring The Intellistat TSTM SwitchLITE Model EZT Features And Benefits Common to Both the SureImage Models Ultra-K/M and the 700F/M • “K(i) Rated” to meet the momentary power demand of medical imaging and treatment equipment. • Significantly reduces / eliminates “artifacts” in the digital image, which enhances workflow, increases patient throughput, and contributes to lower operating costs. • Triple shielded isolation transformer provides excellent common and normal mode noise attenuation. • Low output impedance delivers < 2% load regulation from typical steady state load to intermittent power demand. featuring one of the smallest cabinet footprints in the industry. • Uninterrupted, regulated, continuous sinewave output, compatible with all existing and future lighting loads. • Timed Normally Off Bus “PLUS” option includes an adjustable soft start to accommodate the high inrush current of “normally off” emergency lights. • High-speed automatic static bypass. • Manual bypass switch. • NEMA 2 drip-proof enclosure. double-conversion system, compatible with all existing and future lighting loads. • Automatic static bypass. • Secure, internal make-before-break inverter bypass switch. • Basic and advanced Intellistat TS™ monitoring options. • System approved for 42k AIC rated source. • Online double-conversion technology. • Up to 4 hours of runtime in a front access cabinet design, with zero side or rear clearance requirements. • Color monitor with high-resolution touch-screen display. Model LTN-3R shown • Internal bypass option that “maintains system isolation and voltage transformation”. • Multiple input / output voltage configurations. • Custom-configured output distribution and receptacles. True uninterruptible power, designed for HID, incandescent, halogen, and quartz lighting applications, plus PFC electronic ballast loading up to 50% of the inverter’s rated output. Applications: LAN / WAN, Telecommunications, Industrial Controls Applications: ES, ESV — I.T. Server Rooms, Industrial Controls, and Telemetry HV Series (7.5 kVA to 25 kVA) • Integral constant voltage transformer isolates and regulates output voltage. • Internal bypass option that “maintains system isolation and voltage transformation”. • Optional “System Power Analyzer” local monitor. Applications: Windfarm Power Substations, SCADA / DCS, Extensive LAN / WAN Systems, Industrial Controls Note: “Variable Range Regulation” (using Fuzzy Ranging™ technology) broadens the input operating range of the UPS as a function of load, down to -40% of the input voltage; standard on the LT and MD Series products. Applications: Commercial, Industrial, Schools, Hospitals, Arenas, Mass Transit, Airports, Restaurants, Worship Facilities Features And Benefits Common to All Controlled Power Company LT, MD, and HV Series UPS’s • Steady, regulated output voltage to ± 3% of nominal, extends the life of protected equipment. • Built-in isolation eliminates electrical noise, and provides a “newly derived power source”. • Field-expandable power ratings, and optional extended battery runtimes. • Batteries are pre-assembled, installed, tested, and shipped within the UPS enclosure. (Excluding Model LTN-3R) • No-break, continuous power provides seamless transfer to back-up power, and prevents data loss. • Accelerated battery charger options. • Optional “NetMinder”™ UPS Management Suite software and hardware for UPS monitoring and unattended computer / network shutdown. Features And Benefits Common to All Controlled Power Company Emergency Lighting Inverters • Uninterrupted, regulated power for “normally on” lighting fixtures / exit lamps, and for “normally off” emergency lights. • Meets NFPA 101 and 111 standards. NFPA compliant as “Life Safety Equipment”. • Front access design with small footprint — front access distribution behind a lockable panel door. • UL 924 Listed as “Emergency Lighting Equipment” with standard 90 minutes; optional battery run times available. • Generator-compatible and available with 10 – 15 minutes back-up; UL 924 Listed as “Auxiliary Lighting and Power Equipment”. Download product brochure and specifications from any product webpage: • Model EL3 • Model ELC • Model ELU • Model ELN • Model ELE (1.5 kVA to 14 kVA) (3.1 kVA to 7.5 kVA) ELN (550 W to 1.5 kW Single Phase) ELE (5.3 kW to 18 kW Single Phase) time, without the need for additional cabinetry. • Choice of nominal input voltages, with conversion to the exact nominal output voltage needed, even in bypass. • Color monitor with high-resolution touch-screen display. • Full network communications options. Model ESV MD Series eLITE Models technology. • Extended battery backup • Model EZT 3 Download product brochure and specifications from any product webpage: • Model LT • Model LTN • Model LTN-3R • MD Series • HV Series • Model ES • Model LTR • Model ESV 4 Controlled Power Company engineers and produces the industry’s highest quality electrical power solutions, capitalizing on over 40 years of design and manufacturing expertise. We have an enviable reputation for quality, which is reflected in the design, workmanship, and performance of our products. From Research and Development... through Engineering, Marketing, and Sales... through Manufacturing and Shipping... through Accounting and Customer Support, Controlled Power Company is never content with the status quo in either our products or our attention to our customers. We continue to be a leader in the broad range of markets we serve, by proactively anticipating power quality trends and requirements, and listening attentively to our prospects’ and customers’ needs. Medical-Grade Power Conditioners and UPS MedPoweRx Model LT/M SuiteLITE Model SCLU (700 VA to 2.1 kVA) (600 W to 3000 W) • Battery back-up for patient • Meets the hospital-grade vicinity medical systems. • Less than 300 micro-amps leakage current to ground. • Optional specially-designed wheeled cart for portability. Applications: Mammography, Ultrasound, Fluoroscopy, Dialysis, Hospital Room PC’s, Nurse Call Stations, Fetal Monitor Carts* * Disclaimer: Product not intended for life support applications. Controlled Power Company does not accept any liability for this product being used with ventilators or any other life support systems. lighting power requirements of RF-shielded MRI suites. • Assures a highly-filtered, regulated, dimmable, DC output, and provides illumination without image interference. • Slide dimmer control with on / off switch, or optional in-suite lighting adjustment. • Compact size for easy installation, maintenance-free. Applications: MRI Suite Lighting SureImage Model 700F/M SureImage Model Ultra-K/M (75 K(i) to 225 K(i) Three Phase) • 98% efficiency, typical. • High frequency filter. • Low temperature rise (105˚F). • 146 dB common mode noise attenuation. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology (60 K(i) to 260 K(i) Three Phase) • Output line voltage regulation ± 2%, typical. • Up to 97% efficiency. • Front access enclosure. • Optional input and output metering with real-time monitoring and waveform viewing. • Optional output circuit breakers. Applications: MRI, CT, PET, Molecular Imaging, X-Ray, Cardiology, Linear Accelerator Centralized Emergency Lighting Inverters Uninterruptible Power Supplies (UPS) EON Model EL3 UltraLITE Model ELC LT Series Model ES (10 kW to 33 kW Three Phase) (600 W to 2 kW Single Phase) (700 VA to 2.1 kVA) (4500 VA to 15500 VA) • Computer-based, self-testing / • Compact, front access design, •Tower (Model LT) or • Online, double-conversion self-diagnostic emergency lighting system with data-logging and reporting (NFPA 101, 7.9.3.1.3). • Physically smaller than comparable three-phase emergency lighting inverter products, without compromising performance or serviceability. • Requires only (1) battery cabinet for 90 minutes runtime. • Only batteries with front-access terminals are used. Applications: Theaters / Concert Halls, Auditoriums, Airports, Casinos, Conference / Banquet Centers, Industrial Manufacturing, Warehouses UltraLITE Model ELU • Color, TFT, high resolution touch- (1.5 kW to 14 kW Single Phase) screen display for viewing system parameters, status, alarms, and programming of date / time values and system setpoints. • Provides complete system diagnostics and testing, including all NFPA-compliant automatic battery testing and report logging. • Performs egress lighting integrity test. Download product brochure and specifications from any product webpage: • Model SCLU • Model Ultra-K/M • Model 700F/M 2 © April 2016. Controlled Power Company. Intellistat™, Intellistat TS™, NetMinder™, and Fuzzy Ranging™ are trademarks of Controlled Power Company. • Model LTN-3R outdoor UPS with extended runtimes; NEMA 3R raintight enclosure design. • Elastomeric insulation prevents condensation and internal moisture. • Conformal coated circuit boards. • Runtimes from 30 minutes to 9.5 hours at full load, model dependent. Applications: LT, LTR, LTN — Industrial / Automated Process Controls, Point-of-Sale Computers, Instrumentation LTN-3R — Traffic Controls, Vehicle / Cargo Scanning, Solar Array Controls • Seamless transfer, online Model ELU display shown Available On: UltraLITE Model ELU: 1.5 kW – 14 kW sizes Standard On: EON Model EL3: 10 kW – 33 kW three phase sizes NetMinderTM Communications Remote (BACnet, SNMP, TCP/IP, E-Mail, MODBUS) communication of test results and system status. Provides automatic transfer between normal and emergency power for up to eight (8) individual single phase, 20 amp circuits. • Model LT/M rack-mount (Model LTR) styles available. • Line cord / receptacle or hardwired models. • Model LTN (NEMA 2) UPS with extended battery runtimes; front access style enclosure. Applications: Commercial, Industrial, Schools, Hospitals, Office Buildings, Retail Stores, Multi-Unit Dwellings Advanced Digital Monitoring The Intellistat TSTM SwitchLITE Model EZT Features And Benefits Common to Both the SureImage Models Ultra-K/M and the 700F/M • “K(i) Rated” to meet the momentary power demand of medical imaging and treatment equipment. • Significantly reduces / eliminates “artifacts” in the digital image, which enhances workflow, increases patient throughput, and contributes to lower operating costs. • Triple shielded isolation transformer provides excellent common and normal mode noise attenuation. • Low output impedance delivers < 2% load regulation from typical steady state load to intermittent power demand. featuring one of the smallest cabinet footprints in the industry. • Uninterrupted, regulated, continuous sinewave output, compatible with all existing and future lighting loads. • Timed Normally Off Bus “PLUS” option includes an adjustable soft start to accommodate the high inrush current of “normally off” emergency lights. • High-speed automatic static bypass. • Manual bypass switch. • NEMA 2 drip-proof enclosure. double-conversion system, compatible with all existing and future lighting loads. • Automatic static bypass. • Secure, internal make-before-break inverter bypass switch. • Basic and advanced Intellistat TS™ monitoring options. • System approved for 42k AIC rated source. • Online double-conversion technology. • Up to 4 hours of runtime in a front access cabinet design, with zero side or rear clearance requirements. • Color monitor with high-resolution touch-screen display. Model LTN-3R shown • Internal bypass option that “maintains system isolation and voltage transformation”. • Multiple input / output voltage configurations. • Custom-configured output distribution and receptacles. True uninterruptible power, designed for HID, incandescent, halogen, and quartz lighting applications, plus PFC electronic ballast loading up to 50% of the inverter’s rated output. Applications: LAN / WAN, Telecommunications, Industrial Controls Applications: ES, ESV — I.T. Server Rooms, Industrial Controls, and Telemetry HV Series (7.5 kVA to 25 kVA) • Integral constant voltage transformer isolates and regulates output voltage. • Internal bypass option that “maintains system isolation and voltage transformation”. • Optional “System Power Analyzer” local monitor. Applications: Windfarm Power Substations, SCADA / DCS, Extensive LAN / WAN Systems, Industrial Controls Note: “Variable Range Regulation” (using Fuzzy Ranging™ technology) broadens the input operating range of the UPS as a function of load, down to -40% of the input voltage; standard on the LT and MD Series products. Applications: Commercial, Industrial, Schools, Hospitals, Arenas, Mass Transit, Airports, Restaurants, Worship Facilities Features And Benefits Common to All Controlled Power Company LT, MD, and HV Series UPS’s • Steady, regulated output voltage to ± 3% of nominal, extends the life of protected equipment. • Built-in isolation eliminates electrical noise, and provides a “newly derived power source”. • Field-expandable power ratings, and optional extended battery runtimes. • Batteries are pre-assembled, installed, tested, and shipped within the UPS enclosure. (Excluding Model LTN-3R) • No-break, continuous power provides seamless transfer to back-up power, and prevents data loss. • Accelerated battery charger options. • Optional “NetMinder”™ UPS Management Suite software and hardware for UPS monitoring and unattended computer / network shutdown. Features And Benefits Common to All Controlled Power Company Emergency Lighting Inverters • Uninterrupted, regulated power for “normally on” lighting fixtures / exit lamps, and for “normally off” emergency lights. • Meets NFPA 101 and 111 standards. NFPA compliant as “Life Safety Equipment”. • Front access design with small footprint — front access distribution behind a lockable panel door. • UL 924 Listed as “Emergency Lighting Equipment” with standard 90 minutes; optional battery run times available. • Generator-compatible and available with 10 – 15 minutes back-up; UL 924 Listed as “Auxiliary Lighting and Power Equipment”. Download product brochure and specifications from any product webpage: • Model EL3 • Model ELC • Model ELU • Model ELN • Model ELE (1.5 kVA to 14 kVA) (3.1 kVA to 7.5 kVA) ELN (550 W to 1.5 kW Single Phase) ELE (5.3 kW to 18 kW Single Phase) time, without the need for additional cabinetry. • Choice of nominal input voltages, with conversion to the exact nominal output voltage needed, even in bypass. • Color monitor with high-resolution touch-screen display. • Full network communications options. Model ESV MD Series eLITE Models technology. • Extended battery backup • Model EZT 3 Download product brochure and specifications from any product webpage: • Model LT • Model LTN • Model LTN-3R • MD Series • HV Series • Model ES • Model LTR • Model ESV 4 Power Conditioning Voltage Regulators Power Conditioning Transformers & Power Distribution Units Series 700F Power Processor Series 700A Power Processor Ultra-K Isolation Transformer (10 kVA to 150 kVA Three Phase) (5 kVA to 25 kVA Single Phase) (10 kVA to 1 mVA Three Phase) (5 kVA to 25 kVA Single Phase) (15 kVA to 500 kVA Three Phase) • 7-tap, microproces- • Meets NEMA TP 1-2002 dry type distribution transformer • Front access only! All installa- tion, operation, maintenance, and testing can occur from the front of the unit — no side or rear access required. • Identical voltage regulation and power conditioning performance as the Series 700A. • Front access to all options including a regulator bypass, output distribution circuit breakers, and input / output digital meters. • Advanced monitoring options include data-logging, programmable limit alarms, a waveform scope to view the real-time waveform for voltage and current, plus power quality monitoring with event logging. • Optional communications include Ethernet TCP/IP and MODBUS TCP. Applications: Commercial, Industrial, Power Generation Plants, Refineries, Aerospace, Telecommunications, Pulp / Paper Mills, Industrial Lasers sor-controlled. • Precisely maintains correct voltage to ± 3% within one cycle, and maintains regulation during extended brownouts. • Low output impedance transformer minimizes voltage distortion and sags commonly associated with high surge currents. • Triple-shielded transformer provides a noise-free ground, attenuates voltage spikes and transients, and re-establishes the N-G bond. • Internal bypass option that “maintains system isolation and voltage transformation.” Applications: Food Processing, Pharmaceuticals, Commercial, Industrial, Audio / Visual, Wastewater Treatment, Robotics Series 900/200 Power Commander (“Plus”) (15 kVA to 150 kVA Single Phase) (15 kVA to 450 kVA Three Phase) Series 800 Power Purifier regulated, and noise-free electrical power to protect sensitive electronic equipment. • Variable range regulation increases input voltage range under lighter loads, 800PI models shown while tight output voltage is maintained. • Provides power “ride-through”, even with the loss of input voltage for up to 1 cycle. • 800PI models available in NEMA 1, 2, and 3R enclosures. Applications: 800A — High-End Digital Photography, Security Systems, Medical Labs 800PI — Industrial Networks, Automation Equipment, Machine Tools, PLC’s, Instrumentation • Precise electrical power for critical loads. • Automatic correction of voltage deviations to ± 1% of nominal. • Adjustable output voltage. • Electronically and magnetically regulated — no moving parts, virtually no preventive maintenance required. • High fault-clearing capability. • “Plus” models include computer-grade isolation transformers. Applications: Test Laboratories, Industrial, Commercial, Distributed Control Systems (DCS), Power Generation Authorities, Regulated Bypass for Uninterruptible Power Systems, Broadcast Communications Download product brochure and specifications from any product webpage: • Series 700F • Series 800A • Series 800PI • Series 900/200 • Series 900/200 “Plus” 5 • Series 700A for imaging and treatment modalities, healthcare I.T., MRI suites, and patient vicinity equipment. Applications: Switch Mode Power Supplies, Variable Speed Drives, Sensitive Digital Equipment in Theaters and Recording Studios Download product brochure and specifications from the product webpage: • Ultra-K Output Range from 6 VDC to 1000 VDC; 40 Amps to 35,000 Amps (Consult factory for model specifics.) Emergency Lighting Inverters for commercial, industrial, educational, and medical facilities. Industrial DC Power Supplies (Rectifiers) for plating, anodizing, e-coating, motor testing, and special applications. • Conventional and modular designs; air- or water-cooled models. • Three phase input available from 208 VAC to 600 VAC, 50 Hz or 60 Hz. • Provides isolated, Medical-Grade Power Conditioners and UPS * Harmonic transformers are excluded from the NEMA TP 1-2002 Standard. AACD (Automatic Average Current Density) • Adjusts DC voltage for proper UPS, Power Conditioning Voltage Regulators, and Power Distribution for I.T., telecom, industrial automation, and testing applications. e-coating film thickness. • DC voltage adjustment based on load current to maximize savings on power and paint consumption. • Compatible with batch or continuous conveyor processes. • “Empty tank” power savings. • Standard and custom designs 800A Commercial Model (500 VA to 15 kVA) 800PI Industrial Model (500 VA to 25 kVA) Electrical Power Solutions efficiency standards. • Achieves NEMA TP 1-2002 Table 4-2 efficiencies under a K13 non-linear load at or between 35% - 50% of its rating on models 30 kVA and higher. * • All copper windings and conductors with double-sized neutral. • Removes triplen harmonic currents from the line. • Double- or triple-shielded (146 dB) for high common mode noise attenuation. • Optional Cat. B3 TVSS with output high frequency noise filter. Industrial DC Power Supplies (Rectifiers) for electrocoating, anodizing, and other metal finishing applications. Series 50 Secondary SCR (100A to 5000A) Download product brochure and specifications from any product webpage: • Series 50 • AACD See more of our Industrial DC Power Supplies... visit our Rectifier product-family webpage! UL 60601-1 (Medical) UL 924 / C-UL (Emergency Lighting) UL / C-UL 1778 (Standard UPS) UL 1012 and 1561 (Power Conditioning Transformers) Warranty: Consult factory for specific product warranties, start-up services, and extended coverages. Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. EPS-006-0416 Power Conditioning Voltage Regulators Power Conditioning Transformers & Power Distribution Units Series 700F Power Processor Series 700A Power Processor Ultra-K Isolation Transformer (10 kVA to 150 kVA Three Phase) (5 kVA to 25 kVA Single Phase) (10 kVA to 1 mVA Three Phase) (5 kVA to 25 kVA Single Phase) (15 kVA to 500 kVA Three Phase) • 7-tap, microproces- • Meets NEMA TP 1-2002 dry type distribution transformer • Front access only! All installa- tion, operation, maintenance, and testing can occur from the front of the unit — no side or rear access required. • Identical voltage regulation and power conditioning performance as the Series 700A. • Front access to all options including a regulator bypass, output distribution circuit breakers, and input / output digital meters. • Advanced monitoring options include data-logging, programmable limit alarms, a waveform scope to view the real-time waveform for voltage and current, plus power quality monitoring with event logging. • Optional communications include Ethernet TCP/IP and MODBUS TCP. Applications: Commercial, Industrial, Power Generation Plants, Refineries, Aerospace, Telecommunications, Pulp / Paper Mills, Industrial Lasers sor-controlled. • Precisely maintains correct voltage to ± 3% within one cycle, and maintains regulation during extended brownouts. • Low output impedance transformer minimizes voltage distortion and sags commonly associated with high surge currents. • Triple-shielded transformer provides a noise-free ground, attenuates voltage spikes and transients, and re-establishes the N-G bond. • Internal bypass option that “maintains system isolation and voltage transformation.” Applications: Food Processing, Pharmaceuticals, Commercial, Industrial, Audio / Visual, Wastewater Treatment, Robotics Series 900/200 Power Commander (“Plus”) (15 kVA to 150 kVA Single Phase) (15 kVA to 450 kVA Three Phase) Series 800 Power Purifier regulated, and noise-free electrical power to protect sensitive electronic equipment. • Variable range regulation increases input voltage range under lighter loads, 800PI models shown while tight output voltage is maintained. • Provides power “ride-through”, even with the loss of input voltage for up to 1 cycle. • 800PI models available in NEMA 1, 2, and 3R enclosures. Applications: 800A — High-End Digital Photography, Security Systems, Medical Labs 800PI — Industrial Networks, Automation Equipment, Machine Tools, PLC’s, Instrumentation • Precise electrical power for critical loads. • Automatic correction of voltage deviations to ± 1% of nominal. • Adjustable output voltage. • Electronically and magnetically regulated — no moving parts, virtually no preventive maintenance required. • High fault-clearing capability. • “Plus” models include computer-grade isolation transformers. Applications: Test Laboratories, Industrial, Commercial, Distributed Control Systems (DCS), Power Generation Authorities, Regulated Bypass for Uninterruptible Power Systems, Broadcast Communications Download product brochure and specifications from any product webpage: • Series 700F • Series 800A • Series 800PI • Series 900/200 • Series 900/200 “Plus” 5 • Series 700A for imaging and treatment modalities, healthcare I.T., MRI suites, and patient vicinity equipment. Applications: Switch Mode Power Supplies, Variable Speed Drives, Sensitive Digital Equipment in Theaters and Recording Studios Download product brochure and specifications from the product webpage: • Ultra-K Output Range from 6 VDC to 1000 VDC; 40 Amps to 35,000 Amps (Consult factory for model specifics.) Emergency Lighting Inverters for commercial, industrial, educational, and medical facilities. Industrial DC Power Supplies (Rectifiers) for plating, anodizing, e-coating, motor testing, and special applications. • Conventional and modular designs; air- or water-cooled models. • Three phase input available from 208 VAC to 600 VAC, 50 Hz or 60 Hz. • Provides isolated, Medical-Grade Power Conditioners and UPS * Harmonic transformers are excluded from the NEMA TP 1-2002 Standard. AACD (Automatic Average Current Density) • Adjusts DC voltage for proper UPS, Power Conditioning Voltage Regulators, and Power Distribution for I.T., telecom, industrial automation, and testing applications. e-coating film thickness. • DC voltage adjustment based on load current to maximize savings on power and paint consumption. • Compatible with batch or continuous conveyor processes. • “Empty tank” power savings. • Standard and custom designs 800A Commercial Model (500 VA to 15 kVA) 800PI Industrial Model (500 VA to 25 kVA) Electrical Power Solutions efficiency standards. • Achieves NEMA TP 1-2002 Table 4-2 efficiencies under a K13 non-linear load at or between 35% - 50% of its rating on models 30 kVA and higher. * • All copper windings and conductors with double-sized neutral. • Removes triplen harmonic currents from the line. • Double- or triple-shielded (146 dB) for high common mode noise attenuation. • Optional Cat. B3 TVSS with output high frequency noise filter. Industrial DC Power Supplies (Rectifiers) for electrocoating, anodizing, and other metal finishing applications. Series 50 Secondary SCR (100A to 5000A) Download product brochure and specifications from either product webpage: • Series 50 • AACD See more of our Industrial DC Power Supplies... visit our Rectifier product-family webpage! UL 60601-1 (Medical) UL 924 / C-UL (Emergency Lighting) UL / C-UL 1778 (Standard UPS) UL 1012 and 1561 (Power Conditioning Transformers) Warranty: Consult factory for specific product warranties, start-up services, and extended coverages. Represented by: 1955 Stephenson Hwy., Troy MI 48083 www.controlledpwr.com email: info@controlledpwr.com Phone: (800) 521-4792 Fax: (248) 528-0411 All information and data within this brochure is subject to change without notice. EPS-006-0416