Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series
Mid Series Multi-port
Venturi Vacuum Pumps
with Silencers
Ideal Applications:
VP20/VP20BV-MP • High performance – vacuum up to 28”Hg
[948mbar]
• End-of-Arm Tooling/Robotics
• Pick & place
• Flexible manufacturing
• Packaging – carton erecting, robotic palletizing
• Automation assembly
Features/Benefits:
• High production – fast cycle times with
shot to shot consistency
VP20-60M-MP with vacuum cup
assembly transfers wooden plug
spools for carpet roll application
• High flow – maintains strong holding force,
overcome leakage
• Home Run plumbing – saves compressed air
• Easy mounting – fractional and metric T-slot
compatible
• Time saving – pre-designed, factory assembled,
quick installation
• Safe operation – no electricity needed at pump
VP20BV-90H-MP with ST4 silencer
Vaccon’s Multi-port venturi vacuum pumps combine a venturi with
a manifold to distribute vacuum to multiple locations. The result is a
compact vacuum generation and distribution system for End-of-Arm Tools
and applications where one pump powers multiple cups.
VP20-MP pumps have 4 vacuum ports that distribute vacuum equally to
four locations with “Home-Run” plumbing. The streamlined design minimizes
vacuum loss, maximizes vacuum flow and speeds cycle times for safe,
efficient lifting operations. VP20BV-MP offers an optional integrated valve.
In addition to the 4 topside vacuum ports, there is a port fitted with a 1.5”
diameter glycerin filled vacuum gauge and another port that can be plumbed
to a compressed air source to provide a blow-off. The manifold design allows
one compressed air connection to feed blow-off air to all vacuum locations
simultaneously, saving the need to plumb a separate blow-off line.
An M5 threaded port allows you to connect a Vaccon miniature vacuum
sensor/switch to provide an electrical signal for vacuum achieved/part
present and to alert failures.
• Reliable – non-clogging, trouble-free operation
Performance Level Designations:
“L” 0-10”Hg [0 to 339mbar] for low vacuum/high flow applications
“M” 0-20”Hg [0 to 677mbar] for medium vacuum/high flow applications
“H” 0-28”Hg [0 to 948mbar] for high vacuum/standard flow applications
Pump Options:
• Interchangeable venturi cartridges – 11 different performance levels –
(VP10 & VP20 Series only)
• Silencers - ST4 (straight-through) silencers won’t clog, STAA4 silencers
for ultra quiet operation
• Integrated 2-way valve - 24 VDC, normally closed
• Miniature sensors or switches with quick disconnects
• G port threads for metric machines – an “I” prefix designates products
with metric threads
• Choice of operating pressures to meet machine and factory air supply
80 PSI [5.5 bar] standard (60 PSI [4.1 bar] option)
Vacuum Vacuum Vacuum Vacuum
Principles of Operation:
Vacuum is produced instantly by supplying compressed air to
a Mid series venturi cartridge and is distributed to the vacuum
manifold ports, gauge port, switch/sensor port and the optional
blow-off port if required.
Air Supply
Eliminate the Guesswork: Contact Us!
Vacuum technology isn’t an exact science. To ensure proper product selection, Vaccon offers free application engineering assistance,
a 30 Day Test & Evaluation Program or you can send sample products to our in-house test facility and we will test and size a pump for you.
To download a complete set of drawings in 13 different CAD formats, please visit our website at www.vaccon.com
For more information or technical assistance, please call 508-359-7200 or 800-848-8788 or email engineering@vaccon.com
72
Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
Exhaust
Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series
VP20- (60, 90, 100, 150) (L, M, H) -MP Series Configurations and Options:
All Vaccon pumps offer a variety of options and accessories to meet your specific requirements.
Please configure your pump from the options listed below.
Optional Switches/Sensor
w/Quick Disconnect
VSMN-QD-6 – 6” pigtail & QD
VSMP-QD-6 – 6” pigtail & QD
VTMV-QD-6 – 6” pigtail & QD
AA4 – Silencer
(standard)
On-line Configurator and CAD
Drawings @ www.vaccon.com
New powerful design tool saves you time
by configuring the pump you need on-line.
When complete, simply download the CAD
drawing in any one of 13 different CAD
formats and insert it right into your design.
vST4 – Silencer
(optional)
Get the pump you need,
in the format you like!
Cartridge Assembly
(nozzle & diffuser)
STAA4 – S ilencer
(optional)
Supply Port
NPT or
G Port
Threads
How to Specify:
VG-150-GF – Vacuum Gauge,
Glycerin filled (standard)
Valve Assembly
(optional)
VP20-MP pumps are Fractional
and Metric T-Slot compatible.
See EOAT Section.
VP20 - 60 H - 60 - MP - ST4 - VSMP-QD-6
P/N
Imperial Thread-NPT
VP20
No Valve
VP20BV with Valve Assy
P/N
Metric Thread-G Port
I-VP20 No Valve
I-VP20BV with Valve
P/N
60
90
100
150
Max. Flow Level
(N/A in L)
P/N
L
Max. Vac Level
10"Hg [339 mbar]
(N/A in 60 Series)
20"Hg [677 mbar]
28"Hg [948 mbar]
M
H
P/N
Switch/Sensor
None (Standard)
VSMN-QD-6 Switch – NPN with QD
VSMP-QD-6 Switch – PNP with QD
VTMV-QD-6 Sensor – 1-5VDC Output w/QD
P/N
ST4
STAA4
P/N
60
Silencer
AA4 Closed-End (Standard)
Straight -Through
Hybrid Silencer
Operating Pressure
80 PSI [5.5 bar] (Standard)
60 PSI [4.0 bar]
For complete Performance Data, see page 94.
Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
73
Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series
Standard Pump: VP20- (60, 90, 100, 150) (L, M, H) - MP
X
T
"A"
AIR SUPPLY PORT
"B"
VACUUM
PORTS
(4X)
N
"E" SENSOR PORT
"C" EXHAUST PORT
L
H
P
W
R
M
J
S
V
TYP
K
3X Ø "D"
MOUNTING HOLES
U
X
"F"
AUX VACUUM OR
BLOW-OFF CONN. PORT
Z
Y
X
VP20-90H-MP
VP20-100M-MP
Specifications: Standard VP20-90H-MP
Weight:
12oz [340g]
Noise Level: 64 dB
Model #
VP20-MP
w/AA4
w/ST4
w/STAA4
Model #
I-VP20-MP
w/AA4
w/ST4
w/STAA4
74
Imperial Dimensions (in.)
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
N/A
4.59
1/4 1/4 1/4
1/4
0.21 10-32
0.35 1.53 1.82 1.50 0.38 3.40 1.30 0.20 0.23 1.90 2.75 0.78 0.75 5.05 1.60 1.16
NPT F NPT F NPT F
NPT F
N/A
6.31
Metric Dimensions (mm)
A
B
C
D
E
F
H
J
K
L
M
N
P
R
S
T
U
V
W
X
Y
Z
N/A
116.6
G 1/4 G 1/4 G 1/4 5.3 M5 G 1/4 8.9 38.9 46.2 38.1 9.7 86.4 33.0 5.1 5.8 48.2 69.9 19.8 19.1 128.3 40.6 29.5
N/A
160.3
A
B
C
D
E
F
Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series
Standard Pump: VP20BV- (60, 90, 100, 150) (L, M, H) - MP
M
POWER CONNECT LEADS
24 AWG (.51mm)
BLK -24VDC
RED +24VDC
STAA4 SILENCER
'A' AIR SUPPLY PORT
E
X
'Y' AUX. VACUUM PORT
'B'
VACUUM
PORTS
(4X)
N
M5 AUX. VACUUM PORT
AA4 SILENCER
L
W
'C' EXHAUST PORT
P
J
V
TYP.
R
S
3X
'D'
MOUNTING
HOLES
T
K
U
X
'F'
AUX VACUUM OR
BLOW-OFF CONN. PORT
Z
H
ST4 SILENCER
X
VP20BV-90H-MP
Specifications: Standard VP20BV-90H-MP
Weight:
16.1oz [456.4g]
Noise Level: 64 dB
Model #
Imperial Dimensions (in.)
VP20BV-MP
A
B
C
D
E
F
H
J
K
L
M
N
P
w/AA4
1/8 1/4 1/4
1/4
w/ST4
0.20 0.38
3.13 1.53 1.82 1.50 0.59 3.41 1.10
NPT F NPT F NPT F
NPT F
w/STAA4
Model #
Metric Dimensions (mm)
I-VP20BV-MP A
B
C
D
E
F
H
J
K
L
M
N
P
w/AA4
w/ST4
G 1/8 G 1/4 G 1/4 5.1 9.65 G 1/4 79.50 38.86 46.23 38.10 14.97 86.61 27.94
w/STAA4
R
X
7.75
0.20 1.76 1.65 2.75 0.78 0.75 8.22
9.47
R
S
S
T
T
U
U
V
V
W
W
X
Y
Z
1/8
1.13
NPT
Y
Z
196.85
5.08 44.70 41.91 69.85 19.69 19.05 208.79 G 1/8 28.70
240.54
Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com
75
Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series
VP20-MP Pump Standard Specifications:
Pump Material:
Anodized Aluminum (For silencer material, see page 244 - 248)
Cartridge Material:
Nylon, Buna-N O-ring (Other materials available, see page 8)
Medium:
Filtered (50 Micron) un-lubricated, non-corrosive dry gases
Operating Temperature:
-30° to ~250° F [-34° to ~121°C]
Operating Pressure:80 PSI [5.5 bar] standard or 60 PSI [4.1 bar] – Consult Factory for other operating pressures
Optional 2-Way Valve Specifications:
Valve Type:
Axial 2-Way Solenoid Valve, Normally closed
Valve Body Material:
Brass, Aluminum, Buna-N
Valve Operating Pressure:
Vacuum to 120 PSI [-1 to 8 bar]
Electrical:
24 VDC [-15% to +10% Nominal]
Power Consumption:
4 watts
Response Time:
6 milliseconds
Cycle Rate:
80 cycles/second
Average Life:
100 million cycles or better
Electrical Connection:
2 Pin Connector with 24 AWG, 18” leads [457.2mm]
LED Indicator:
Yes
VP20-MP Operating and Installation Requirements:
76
Cartridge size:
C60 (M, H) and C90 (L, M, H)
C100 (L, M, H) and C150 (L, M, H)
Supply Line:
1/4” O.D. [6mm] tube recommended
3/8” O.D. [10mm] tube recommended
Vacuum Line:
1/4” O.D. [6mm] tube recommended
3/8” O.D. [10mm] tube recommended
Vacuum Line Filtration:
Typically vacuum filters are not required. If desired, Vaccon recommends – VF250LPM. See page 254. Control Valve:
3 way/2 position (faster part release), minimum orifice – 0.125” [3mm]
Mounting Holes:
Mounting holes accept 10-32 or M5 screws