Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series Mid Series Multi-port Venturi Vacuum Pumps with Silencers Ideal Applications: VP20/VP20BV-MP • High performance – vacuum up to 28”Hg [948mbar] • End-of-Arm Tooling/Robotics • Pick & place • Flexible manufacturing • Packaging – carton erecting, robotic palletizing • Automation assembly Features/Benefits: • High production – fast cycle times with shot to shot consistency VP20-60M-MP with vacuum cup assembly transfers wooden plug spools for carpet roll application • High flow – maintains strong holding force, overcome leakage • Home Run plumbing – saves compressed air • Easy mounting – fractional and metric T-slot compatible • Time saving – pre-designed, factory assembled, quick installation • Safe operation – no electricity needed at pump VP20BV-90H-MP with ST4 silencer Vaccon’s Multi-port venturi vacuum pumps combine a venturi with a manifold to distribute vacuum to multiple locations. The result is a compact vacuum generation and distribution system for End-of-Arm Tools and applications where one pump powers multiple cups. VP20-MP pumps have 4 vacuum ports that distribute vacuum equally to four locations with “Home-Run” plumbing. The streamlined design minimizes vacuum loss, maximizes vacuum flow and speeds cycle times for safe, efficient lifting operations. VP20BV-MP offers an optional integrated valve. In addition to the 4 topside vacuum ports, there is a port fitted with a 1.5” diameter glycerin filled vacuum gauge and another port that can be plumbed to a compressed air source to provide a blow-off. The manifold design allows one compressed air connection to feed blow-off air to all vacuum locations simultaneously, saving the need to plumb a separate blow-off line. An M5 threaded port allows you to connect a Vaccon miniature vacuum sensor/switch to provide an electrical signal for vacuum achieved/part present and to alert failures. • Reliable – non-clogging, trouble-free operation Performance Level Designations: “L” 0-10”Hg [0 to 339mbar] for low vacuum/high flow applications “M” 0-20”Hg [0 to 677mbar] for medium vacuum/high flow applications “H” 0-28”Hg [0 to 948mbar] for high vacuum/standard flow applications Pump Options: • Interchangeable venturi cartridges – 11 different performance levels – (VP10 & VP20 Series only) • Silencers - ST4 (straight-through) silencers won’t clog, STAA4 silencers for ultra quiet operation • Integrated 2-way valve - 24 VDC, normally closed • Miniature sensors or switches with quick disconnects • G port threads for metric machines – an “I” prefix designates products with metric threads • Choice of operating pressures to meet machine and factory air supply 80 PSI [5.5 bar] standard (60 PSI [4.1 bar] option) Vacuum Vacuum Vacuum Vacuum Principles of Operation: Vacuum is produced instantly by supplying compressed air to a Mid series venturi cartridge and is distributed to the vacuum manifold ports, gauge port, switch/sensor port and the optional blow-off port if required. Air Supply Eliminate the Guesswork: Contact Us! Vacuum technology isn’t an exact science. To ensure proper product selection, Vaccon offers free application engineering assistance, a 30 Day Test & Evaluation Program or you can send sample products to our in-house test facility and we will test and size a pump for you. To download a complete set of drawings in 13 different CAD formats, please visit our website at www.vaccon.com For more information or technical assistance, please call 508-359-7200 or 800-848-8788 or email engineering@vaccon.com 72 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com Exhaust Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series VP20- (60, 90, 100, 150) (L, M, H) -MP Series Configurations and Options: All Vaccon pumps offer a variety of options and accessories to meet your specific requirements. Please configure your pump from the options listed below. Optional Switches/Sensor w/Quick Disconnect VSMN-QD-6 – 6” pigtail & QD VSMP-QD-6 – 6” pigtail & QD VTMV-QD-6 – 6” pigtail & QD AA4 – Silencer (standard) On-line Configurator and CAD Drawings @ www.vaccon.com New powerful design tool saves you time by configuring the pump you need on-line. When complete, simply download the CAD drawing in any one of 13 different CAD formats and insert it right into your design. vST4 – Silencer (optional) Get the pump you need, in the format you like! Cartridge Assembly (nozzle & diffuser) STAA4 – S ilencer (optional) Supply Port NPT or G Port Threads How to Specify: VG-150-GF – Vacuum Gauge, Glycerin filled (standard) Valve Assembly (optional) VP20-MP pumps are Fractional and Metric T-Slot compatible. See EOAT Section. VP20 - 60 H - 60 - MP - ST4 - VSMP-QD-6 P/N Imperial Thread-NPT VP20 No Valve VP20BV with Valve Assy P/N Metric Thread-G Port I-VP20 No Valve I-VP20BV with Valve P/N 60 90 100 150 Max. Flow Level (N/A in L) P/N L Max. Vac Level 10"Hg [339 mbar] (N/A in 60 Series) 20"Hg [677 mbar] 28"Hg [948 mbar] M H P/N Switch/Sensor None (Standard) VSMN-QD-6 Switch – NPN with QD VSMP-QD-6 Switch – PNP with QD VTMV-QD-6 Sensor – 1-5VDC Output w/QD P/N ST4 STAA4 P/N 60 Silencer AA4 Closed-End (Standard) Straight -Through Hybrid Silencer Operating Pressure 80 PSI [5.5 bar] (Standard) 60 PSI [4.0 bar] For complete Performance Data, see page 94. Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com 73 Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series Standard Pump: VP20- (60, 90, 100, 150) (L, M, H) - MP X T "A" AIR SUPPLY PORT "B" VACUUM PORTS (4X) N "E" SENSOR PORT "C" EXHAUST PORT L H P W R M J S V TYP K 3X Ø "D" MOUNTING HOLES U X "F" AUX VACUUM OR BLOW-OFF CONN. PORT Z Y X VP20-90H-MP VP20-100M-MP Specifications: Standard VP20-90H-MP Weight: 12oz [340g] Noise Level: 64 dB Model # VP20-MP w/AA4 w/ST4 w/STAA4 Model # I-VP20-MP w/AA4 w/ST4 w/STAA4 74 Imperial Dimensions (in.) H J K L M N P R S T U V W X Y Z N/A 4.59 1/4 1/4 1/4 1/4 0.21 10-32 0.35 1.53 1.82 1.50 0.38 3.40 1.30 0.20 0.23 1.90 2.75 0.78 0.75 5.05 1.60 1.16 NPT F NPT F NPT F NPT F N/A 6.31 Metric Dimensions (mm) A B C D E F H J K L M N P R S T U V W X Y Z N/A 116.6 G 1/4 G 1/4 G 1/4 5.3 M5 G 1/4 8.9 38.9 46.2 38.1 9.7 86.4 33.0 5.1 5.8 48.2 69.9 19.8 19.1 128.3 40.6 29.5 N/A 160.3 A B C D E F Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series Standard Pump: VP20BV- (60, 90, 100, 150) (L, M, H) - MP M POWER CONNECT LEADS 24 AWG (.51mm) BLK -24VDC RED +24VDC STAA4 SILENCER 'A' AIR SUPPLY PORT E X 'Y' AUX. VACUUM PORT 'B' VACUUM PORTS (4X) N M5 AUX. VACUUM PORT AA4 SILENCER L W 'C' EXHAUST PORT P J V TYP. R S 3X 'D' MOUNTING HOLES T K U X 'F' AUX VACUUM OR BLOW-OFF CONN. PORT Z H ST4 SILENCER X VP20BV-90H-MP Specifications: Standard VP20BV-90H-MP Weight: 16.1oz [456.4g] Noise Level: 64 dB Model # Imperial Dimensions (in.) VP20BV-MP A B C D E F H J K L M N P w/AA4 1/8 1/4 1/4 1/4 w/ST4 0.20 0.38 3.13 1.53 1.82 1.50 0.59 3.41 1.10 NPT F NPT F NPT F NPT F w/STAA4 Model # Metric Dimensions (mm) I-VP20BV-MP A B C D E F H J K L M N P w/AA4 w/ST4 G 1/8 G 1/4 G 1/4 5.1 9.65 G 1/4 79.50 38.86 46.23 38.10 14.97 86.61 27.94 w/STAA4 R X 7.75 0.20 1.76 1.65 2.75 0.78 0.75 8.22 9.47 R S S T T U U V V W W X Y Z 1/8 1.13 NPT Y Z 196.85 5.08 44.70 41.91 69.85 19.69 19.05 208.79 G 1/8 28.70 240.54 Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com 75 Multi-port Venturi Vacuum Pumps w/ Optional Solenoid Valve – Mid Series VP20-MP Pump Standard Specifications: Pump Material: Anodized Aluminum (For silencer material, see page 244 - 248) Cartridge Material: Nylon, Buna-N O-ring (Other materials available, see page 8) Medium: Filtered (50 Micron) un-lubricated, non-corrosive dry gases Operating Temperature: -30° to ~250° F [-34° to ~121°C] Operating Pressure:80 PSI [5.5 bar] standard or 60 PSI [4.1 bar] – Consult Factory for other operating pressures Optional 2-Way Valve Specifications: Valve Type: Axial 2-Way Solenoid Valve, Normally closed Valve Body Material: Brass, Aluminum, Buna-N Valve Operating Pressure: Vacuum to 120 PSI [-1 to 8 bar] Electrical: 24 VDC [-15% to +10% Nominal] Power Consumption: 4 watts Response Time: 6 milliseconds Cycle Rate: 80 cycles/second Average Life: 100 million cycles or better Electrical Connection: 2 Pin Connector with 24 AWG, 18” leads [457.2mm] LED Indicator: Yes VP20-MP Operating and Installation Requirements: 76 Cartridge size: C60 (M, H) and C90 (L, M, H) C100 (L, M, H) and C150 (L, M, H) Supply Line: 1/4” O.D. [6mm] tube recommended 3/8” O.D. [10mm] tube recommended Vacuum Line: 1/4” O.D. [6mm] tube recommended 3/8” O.D. [10mm] tube recommended Vacuum Line Filtration: Typically vacuum filters are not required. If desired, Vaccon recommends – VF250LPM. See page 254. Control Valve: 3 way/2 position (faster part release), minimum orifice – 0.125” [3mm] Mounting Holes: Mounting holes accept 10-32 or M5 screws Phone: 1-800-848-8788 or 508-359-7200 E-Mail: engineering@vaccon.com