C60H Single Pole RCBO C60H Single Pole RCBO Whether you are trying to incorporate earth leakage protection into a main switchboard or a distribution board... C60H Single Pole RCBO Single Pole RCBO - 10kA Technical Data Sensitivity Rating Width in mod. of 9mm Reference C60H single pole 30mA type AC 10A 2 26858 RCBO 16A 2 26859 C curve 20A 2 26860 32A 2 26861 L OUT Description IN OUT IN T L N U O T U L OUT O BSEN 61009 IEC 1009 L 10000 3 • Clip on Auxiliaries Standards: IEC60898, AS/NZS4898, AS3190 Approval number N13634 M E R L IN G E R IN IN IN T L N U O T OUT U O L OUT L IN T U O T U O L OUT L reset 26927 26924 Rated voltage N BSEN 61009 IEC 1009 Description SD Test OUT IN L BSEN 61009 IEC 1009 10000 3 0 -0FF 0 -0FF multi 9 C60H R C B O 45A R100 I∆ n 100mA 240V a 26870 M E R L IN G E R IN M E R L IN G E R IN 3 3 10000 M E R L IN G E R IN multi 9 C60H R C B O 45A R100 I∆ n 100mA 240V a 26870 0 -0FF 10000 3 10000 multi 9 C60H R C B O 45A R100 I∆ n 100mA 240V a 26870 IN multi 9 C60H R C B O IN 0 -0FF L 45A R100 OUT BSEN 61009 IEC 1009 N OUT OUT L I∆ n 100mA IN L OUT 240V a L IN BSEN 61009 IEC 1009 OUT N OUT OUT L 0 -0FF M E R L IN G E R IN multi 9 C60H R C B O L OUT 45A R100 3 10000 M E R L IN G E R IN multi 9 C60H R C B O 45A R100 I∆ n 100mA 240V a 26870 0 -0FF L & N out: tunnel terminals 16mm2 cables OF 26870 IN I∆ n 100mA IN MADE 240V a L ALIAN 26870 OUT BSEN 61009 IEC 1009 N OUT OUT L AUSTR • Voltage rating: 110 - 240V AC • Breaking capacity Icn - 10kA • Residual breaking capacity I∆m - 6kA • Current ratings In - 10 ...32A • Electrical endurance (O-C cycles): 20 000 • Tropicalisation: treatment 2 (relative humidity: 95% at 55˚C) • Weight 240g • Connection: • L in: tunnel terminals 25mm2 cables OF auxiliary switch SD alarm switch OF auxiliary switch SD alarm switch Width in mod. of 9mm Reference 1 26924 1 26927 C Curve tripping curve: the magnetic trip operates between 5 and 10 In Tripping Curves 10 000 5 000 1h 2 000 times (s) instantaneous 30 mA 1 000 500 MX+OF shunt trip voltage release ...you will save time & money with the C60H single pole RCBO 240-415V AC 110-130V DC 2 48-130V AC 48VDC 2 200 100 26946 1000 50 20 10 26947 multi 9 MN multi 9 MX OF D1 D2 U< 110.130V 220.415Va 26946 220.415Va 26960 MN undervoltage release 220-240V AC 2 1 .5 MERLIN GERIN MERLIN GERIN 100 5 t(s) 2 26960 10 .2 1 .1 .05 0.37 0.20 .02 .01 48V AC MX+OF shunt trip MN undervoltage release 48V DC 2 2 26961 0.15 .005 .002 .001 .5 .7 1 0.05 0.03 2 3 4 5 7 10 20 30 50 70 100 200 300 0.010 26962 MERLIN GERIN MERLIN GERIN multi 9 multi 9 C60H RCBO C60H RCBO C45 R100 10000 I∆n 100mA 3 240Va 26870 10000 I∆n 100mA 3 240Va 26870 O - OFF O - OFF Reference Sealable, line side terminal screw shields 26981 18 45 111 26970 BSEN 61009 IEC 1009 IN L IN L L L O UT O UT O UT O UT L OUT IN IN N OUT Sealable terminal screw shields L OUT 48 N OUT Padlocking attachment 0.300 Minimum distance to metal escutcheon 4mm 44 Description Padlocking attachment BSEN 61009 IEC 1009 0.100 Dimensions Accessories C45 R100 0.030 I / In 51 18 5,5 66 9 3000 (A) current (I∆n) C60H Single Pole RCBO C60H Single Pole RCBO C60H Single Pole RCBO Your favourite miniature circuit breaker now incorporates residual current protection... Aesthetics & Convenience Product Design ➀ ➁ ➂ ➃ ➄ ➅ ➆ ➇ ➈ ➉ • Same profile as all other multi 9 devices • Toggle position same as multi 9 MCB’s • Full range of auxiliaries & accessories • Auxiliaries & accessories common to standard MCB’s • High stacking density = smaller chassis & distribution boards • Tunnel terminals accept cables up to 16mm2 Performance & Safety Single case construction - ensures product robustness Industry proven C60H MCB mechanism Provision of functional earth ensures safe operation even with loss of neutral connection Suitable for isolation - handle position always indicates contact position Test trip button - conveniently positioned for periodic testing Incoming line connection terminal Outgoing line connection terminal Incoming neutral connection Outgoing neutral connection Foolproof terminal design: - moving barrier prevents incorrect cable insertion - cable strand centring guides ensure correct cable positions & strand grouping ➁ ➅➉ • High interrupting capacity - 10kA • 100% compatible with multi 9 chassis & distribution boards ➃ • Positive contact indication - suitable for isolation • Loss of neutral protection - automatic tripping ➄ • Padlockable with standard multi 9 lock dog ➆➉ • Direction of toggle operation same as multi 9 MCB’s & complies ➈➉ ➀ with AS3000:2000 clause 2.9.2.3 ➇ ➂ Reliability & Continuity of Service ...all in a single pole width • Enhanced discrimination with Merlin Gerin NS range of MCCB’s • Back up to 50kA with BS & DIN fuses • Retrofits multi 9 MCB’s with no chassis tee off or escutcheon modifications • Robust single case construction NEW SOUTH WALES OFFICE Norwest Business Park 2 Solent Circuit Baulkham Hills 2153 Sydney NSW Tel: (02) 9851 2800 Fax: (02) 9629 8555 VICTORIA SALES OFFICE &MANUFACTURING 77 Ricketts Road Mt. Waverley 3149 Melbourne VIC Tel: (03) 9558 9876 Fax: (03) 9558 9701 Medium Voltage Switchgear Tel: (03) 9558 9876 Fax: (03) 9558 9700 Medium Voltage Transformers Tel: Fax (03) 5762 3411 (03) 5762 5113 QUEENSLAND OFFICE 30 Graystone Street Tingalpa 4173 Brisbane QLD Tel: (07) 3890 2112 Fax: (07) 3890 2098 SOUTH AUSTRALIA OFFICE Building 1A Corbett Court Export Park Adelaide Airport 5950 Adelaide SA Tel: (08) 8234 4388 Fax: (08) 8234 4122 WESTERN AUSTRALIA OFFICE 26 Gibberd Road Balcatta 6021 Perth WA Tel: (08) 9344 2727 Fax: (08) 9344 6335 AUS990301