CROUZET Switches & Sensors 1415 S Roselle Road Palatine IL 60067 USA Customer Service : 1-800-677-5311 http://www.crouzet.com PBX Secure ® Presentation PBX Secure main technical features : > Dimensions : According to DIN 41 636 form F > Electrical configuration: Change-over double break with four terminals, electrical separation (form Zb) > Standard and low level electrical rating versions I(mA) > Safety : Direct opening action according to IEC 60947-5-1 Annex K > Technical advantage: Long overtravel beyond positive opening position > Sealing (Mechanism/Terminals): IP40/IP00-IP20 and IP67/IP00-IP20 > Environment : Operating temperatures -50°C to +85°C (-58°F to +185°F) > Choice of accessories: Levers, mounting brackets and covers > Ability to customize depending on the technical requirements: specific connectors, protection covers, actuators… Sealing The PBX Secure range includes an IP40 and a sealed IP 67 version. With any version, the PBX plunger is equipped with a silicon membrane which protects the contacts against external pollutions (dust and fluids). For the IP67 version, a joint makes the sealing inside the housing, and potting resin strengthens the sealing between the terminals and the housing. Direct Opening Action and Long Overtravel Crouzet offers a switch insuring a very high contact reliability. This solution has been validated by many mechanical endurance tests made by various Crouzet customers, especially in the railway and off-road markets. The PBX switch guarantees the opening of the contacts with its positive break mechanism (cf. standard IEC 60 947-51). The product intrinsically gets a long overtravel after the positive opening position (POP), allowing it to absorb the mechanical tolerances. This offers a greater flexibility for implementation for customers. This patented contact block, from the proven Crouzet Industrial Limit Switch product family, is very efficient (more than 10 million cycles) and operates in extreme temperature environments (qualified for -50°C/-58°F). Protection Degree and Low Temperature Crouzet is proud to offer a unique product with an IP67 level and a -50°C/-58°F minimum operating temperature to be compliant with DIN 41636 form F and IEC 60947-5-1. PBX Standards, Conformity and Approvals The PBX Range has been developed according to industrial and railway standards. Product standard: IEC 60947-5-1 Positive opening operation: IEC 60947-5-1 Annex K Product Dimensions: DIN 41 636 FORM F Insulation coordination following IEC 60 947-1 o Pollution degree : III o Rated impulse withstand voltage Uimp : 4kV o Insulation voltage: 400V Insulation coordination following EN 50124-1 (Railway standards) o Pollution degree: 3A o Rated impulse withstand voltage Uimp : 2.5kV o Insulation voltage: 150V Fire and Smoke Resistance o UL94-V0 o IEC 60695-2-12 GWFI 960°C (1760°F) o NFF 16 101 and NFF 16 102 Protection degree (Mechanism/Terminals) o IEC 60529 - IP40/IP00-IP20 - IP67/IP00-IP20 Approvals o SNCF (French Railway) qualification approval (registration 10-5312 235 and 10-5312 134) o CCC o Contact us PBX Qualification Synthesis The tables below give an overview on the tests that have been applied and the associated standards. Electrical Tests Test Contact Resistance Related Standard NFC 93 050 Level / Goal Status < 15 mΩ measured at 1A 30V > 5000MΩ at 500VDC between open contacts and between contacts and ground 1500 V between open contacts 2000 V between separate circuits and between contacts and ground Max 4.4mm. Measured by neutralizing snap action mechanism and checking for 2.5kV across contacts No damage upon applying a 5N force on each of the 2 NC contacts, and simultaneously a 28N force on plunger. Temperature rise on parts do not exceed standard limits when carrying a 10A current AC15 / 250 V / 6 A 100,000 cycles AC15 / 250 V / 2.5 A 1,000,000 cycles DC13 / 125 V / 0.5 A L/R = 100 ms 100,000 cycles DC13 / 125 V / 0.2 A L/R = 50 ms 1,000,000 cycles 110 VDC / 1 A L/R = 5 ms 200,000 cycles 24 VDC /10mA 2,000,000 cycles Insulation Resistance NFC 93 050 Dielectric Strength NFC 93 050 Positive Opening Position Crouzet criterion Positive Opening Operation Robustness of mechanical transmitter IEC 60947-5-1 annex K Thermal Rating IEC 60 947- 5-1 Electrical Endurance IEC 60 947- 5-1 Electrical Endurance IEC 60 947- 5-1 Electrical Endurance IEC 60 947- 5-1 Electrical Endurance IEC 60 947- 5-1 Electrical Endurance IEC 60 947- 5-1 Electrical Endurance (low energy ) IEC 60 947- 5-4 Short-Circuit protection IEC 60 947- 5-1 6AgG Fuse . Tested at 1000A short circuit current Impulse withstand voltage CEI 60060 - 1.2 / 50 µs 2.5 kV pulse : between open contacts 5 kV pulse : between contacts and ground Environmental Tests Test Related Standard Mechanical Durability Min Operating Temperature Max Operating Temperature Damp Heat Salt Spray Rapid change of Temperature Crouzet criterion IEC 60068-2-1 IEC 60068-2-2 IEC 60068-2-30 IEC 60068-2-11 IEC 60068-2-14 Sinus Vibrations IEC 60068-2-6 Random Vibrations endurance Tests EN 61 373 Shocks IEC 60068-2-27 Degree of protection IP6x IEC 60 529 Degree of protection IPx7 IEC 60 529 Level / Goal 10 M cycles at full travel - 2 Hz Correct operation after a 24h storage at -50°C/-58°F Correct operation after a 24h storage at +85°C/+185°F 55°C(131°F) /95% relative humidity /6 cycles 96h Low T : -50°C(-58°F) / High T : +85°C(+185°F) 10g - 15Hz to 500Hz : 3 axis with no micro-opening of contacts > 10µs 5-150Hz 0.18g²/Hz 0.79g (rms) 5 hours on each axis with no micro-opening of contacts > 10µs 50g/11ms on 3 axis with no micro-opening of contacts > 10µs no dust ingress 1m immersion in water during 30' with no water ingress Status