Deutsche Akkreditierungsstelle GmbH Annex to the Accreditation Certificate D-PL-20258-01-00 according to DIN EN ISO/IEC 17025:2005 Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 Holder of certificate: Amphenol-Tuchel Electronics Gesellschaft mit beschränkter Haftung Prüflaboratorium August-Häusser-Straße 10, 74080 Heilbronn Tests in the fields: Electrical, mechanical and environmental simulation tests under inclusion of temperature, humidity, corrosion, IP degree of protection, vibration and mechanical shock as well as combinations thereof for the validation of connectors and other technical products Within the scope of accreditation marked with *), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, to use standards or equivalent testing methods listed here with different issue dates. Within the given testing field marked with #), the testing laboratory is permitted, without being required to inform and obtain prior approval from DAkkS, the following: the free choice of standard or equivalent testing methods. The listed testing methods are exemplary. The testing laboratory maintains a current list of all testing methods within the flexible scope of accreditation. Testing field Connectors * Standard / In-House Procedure / Version DIN EN 60512-11:2013-01 Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions Connectors for electronic equipment - Tests and measurements - Part1-1: General examination; Test1a: Visual examination (IEC60512-1-1:2002 This document is a translation. The definitive version is the original German annex to the accreditation certificate. 1/7 Annex to the accreditation certificate D-PL-20258-01-00 Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Connectors * DIN EN 60512-21:2003-01 Connectors for electronic equipment - Tests and measurements – Part 2-1: Electrical continuity and contact resistance tests; Test 2a: Contact resistance; Millivolt level method (IEC 60512-2-1:2002) Connectors * DIN EN 60512-22:2004-01 Connectors for electronic equipment- Tests and measurements- Part 2-2: Electrical continuity and contact resistance tests – Test 2b: Contact resistance - Specified test current method (IEC 60512-2-2:2003) Connectors * DIN EN 60512-26:2003-01 Connectors for electronic equipment - Tests and measurements – Part 2-6: Electrical continuity and contact resistance tests; Test 2f: Housing (shell) electrical continuity (IEC 60512-2-6:2002) Connectors * DIN EN 60512-31:2003-01 Connectors for electronic equipment - Tests and measurements – Part 3-1: Insulation tests; Test 3a: Insulation resistance (IEC 60512-3-1:2002) Connectors * DIN EN 60512-41:2004-01 Connectors for electronic equipment - Tests and measurements – Part 4-1: Voltage stress tests – Test 4a: Voltage proof (IEC 60512-4-1:2003) Connectors * DIN EN 60512-51:2003-01 Connectors for electronic equipment - Tests and measurements – Part 5-1: Currentcarrying capacity tests; Test 5a: Temperature rise (IEC 60512-5-1:2002); Connectors * DIN EN 60512-52:2003-01- Connectors for electronic equipment - Tests and measurements – Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002) Connectors * DIN EN 60512-63:2003-01 Connectors for electronic equipment - Tests and measurements – Part 6-3: Dynamic stress tests; Test 6c: Shock (IEC 60512-63:2002) Connectors * DIN EN 60512-64:2003-01 Connectors for electronic equipment - Tests and measurements – Part 6-4: Dynamic stress tests; Test 6d: Vibration (sinusoidal) (IEC 60512-6-4:2002) Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 - Translation - Test Range / Restrictions 2/7 Annex to the accreditation certificate D-PL-20258-01-00 Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Connectors * DIN EN 60512-65:2003-01 Connectors for electronic equipment - Tests and measurements – Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002) Connectors * DIN EN 60512-91:2010-12 Connectors for electronic equipment - Tests and measurements- Part 9-1: Endurance tests – Test 9a: Mechanical operation (IEC 60512-9-1:2010) Connectors * DIN EN 60512-92:2012-09 Connectors for electronic equipment - Tests and measurements – Part 9-2: Endurance tests - Test 9b: Electrical load and temperature (IEC 60512-9-2:2011) Connectors * DIN EN 60512-95:2010-12 Connectors for electronic equipment - Tests and measurements – Part -5: Endurance tests – Test 9e: Current loading, cyclic (IEC 60512-9-5:2010) Connectors * DIN EN 60512-104:2004-06 Connectors for electronic equipment- Tests and measurements – Part 10-4: Impact tests (free components), static load tests and overload tests - endurance tests and overload tests – Test 10d: Electrical overload (connectors) (IEC 60512-10-4:2003); Connectors * DIN EN 60512-111:1999-08 Electromechanical components for electronic equipment - Basic testing procedures and measuring methods – Part 11: Climatic tests; Section 1: Test 11a: Climatic sequence (IEC 60512-11-1:1995) Connectors * DIN EN 60512-131:2006-11 Connectors for electronic equipment - Tests and measurements – Part 13-2: Mechanical operation tests – Test 13b: Insertion and withdrawal forces (IEC 60512-13-2:2006 Connectors * DIN EN 60512-132:2006-11 Connectors for electronic equipment - Tests and measurements – Part 13-2: Mechanical operation tests – Test 13b: Insertion and withdrawal forces (IEC 60512-13-2:2006) Connectors * DIN EN 60512-135:2006-11 Connectors for electronic equipment - Tests and measurements – Part 13-5: Mechanical operation tests – Test 13e: Polarizing and keying method (IEC 60512-13-5:2006) Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 - Translation - Test Range / Restrictions Low pressure tests exempted 3/7 Annex to the accreditation certificate D-PL-20258-01-00 Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions Connectors * DIN EN 61984:200911 Connectors * DIN EN 60352-2:2014- Solderless connections – Part 2: Crimped 04 connections - General requirements, test methods and practical guidance (IEC 603522:2006) Connectors * DIN EN 60529:201409 Degrees of protection provided by enclosures (IP Code) (IEC 60529:1989 + A1:1999 + A2:2013) Limited to: Protection against contact IP 1x up to IP4x Water tightness IPx7 and IPx8 Degree of protection * ISO 20653:2013-02 Road vehicles - Degrees of protection (IP code) - Protection of electrical equipment against foreign objects, water and access Limited to: Protection against contact IP 1x up to IP4x Water tightness IPx7 and IPx8 Connectors VW 75174:2010-04 Climatic Testing * Motor vehicle connectors – Test specification DIN EN 60068-2-31 DIN EN 60512-1114 DIN EN 60512-14-5 DIN EN 60068-2-13 DIN EN 60512-15-6 DIN EN 60512-1-2 DIN EN 60512-1-3 DIN EN 60512-1-4 DIN 40050-9 Connectors Climatic Testing *# VW 75174-2:2008-01 Motor vehicle connectors - Slow-Motion Test Exempted Mixed flowing gastest ( MFG 4) Connectors Climatic Testing *# VW 60330:2013-12 Crimped connections Solderless electrical connections Exempted DIN EN 60512-16-8 Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 Connectors- Safety requirements and tests (IEC 61984:2008) - Translation - 4/7 Annex to the accreditation certificate D-PL-20258-01-00 Testing field Standard / In-House Procedure / Version Title of Standard or In-House Procedure (Deviations / Modifications of Standard) Test Range / Restrictions Environmental DIN EN 60068-2Simulation*# 1:2008-01 Environmental testing – Part 2-1: Tests – Test A: Cold (IEC 60068-2-1:2007) Environmental DIN EN 60068-2Simulation*# 2:2008-05 Environmental testing – Part 2-2: Tests – Test B: Dry heat (IEC 60068-2-2:2007) Environmental DIN EN 60068-2Simulation*# 6:2008-10 Environmental testing- Part 2-6: Tests - Test Fc: Vibration (sinusoidal) (IEC 60068-2-6:2007) Environmental DIN EN 60068-2Simulation*# 11:2000-02 Environmental testing – Part 2: Tests; test Ka: Salt mist (IEC 60068-2-11:1981) Environmental DIN EN 60068-2Simulation*# 14:2010-04 Environmental testing – Part 2-14: Tests – Test N: Change of temperature (IEC 60068-2-14:2009) Environmental DIN EN 60068-2Simulation*# 27:2010-02 Environmental testing – Part 2-27: Tests – Test Ea and guidance: Shock (IEC 60068-2-27:2008) Environmental DIN EN 60068-2Simulation*# 30:2006-06 Environmental testing – Part 2-30: Tests – Test Db: Damp heat, cyclic (12h + 12h cycle) (IEC 60068-230:2005) Environmental DIN EN 60068-2Simulation*# 38:2010-06 Environmental testing – Part 2-38: Tests – Test Z/AD: Composite temperature/humidity cyclic test (IEC 60068-2-38:2009) Environmental DIN EN 60068-2Simulation*# 52:1996-10 Environmental testing – Part 2: Tests, Test Kb: Salt mist, cyclic (sodium chloride solution) (IEC 600682-52:1996) Environmental DIN EN 60068-2Simulation*# 61:1993-12 Environmental testing; part 2: test methods; test Low pressure Z/ABDM: climatic sequence (IEC 60068-2-61:1991) tests exempted Environmental DIN EN 60068-2Simulation*# 64:2009-04 Environmental testing – Part 2-64: Tests – Test Fh: Vibration, broadband random and guidance (IEC 60068-2-64:2008); Environmental DIN EN 60068-2Simulation*# 78:2014-02 Environmental testing – Part 2-78: Tests - Test Cab: Damp heat, steady state (IEC 60068-2-78:2012) Corrosion*# DIN EN ISO 9227:2012-09 Corrosion tests in artificial atmospheres - Salt spray tests (ISO 9227:2012) Only NSS Corrosion*# ASTM B 117:2011 Standard Practice for Operating Salt Spray (Fog) Apparatus Only NSS Corrosion*# DIN EN ISO 62702:2005-09 Paints and varnishes - Determination of resistance to humidity – Part 2: Procedure for exposing test specimens in condensation-water atmospheres (ISO 6270-2:2005); Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 - Translation - 5/7 Annex to the accreditation certificate D-PL-20258-01-00 Type of testing testing area / value range Measurement uncertainty limit deviation example standard Heat / Cold # -70°C up to +180°C - ±2 K DIN EN 60068-2-1 DIN EN 60068-2-2 Temperature Change # -70°C up to +180°C - ±2 K DIN EN 60068-2-14 Nb Temperature Shock # 70°C up to +180°C - ±2 K DIN EN 60068-2-14 Na Temperature # 70°C up to +180°C ±0,25 K - - Humidity # 10 % up to 100 % RH ±3% RH DIN EN 60068-2-78 DIN EN ISO 6270-2 CHT Temperature Humidity cyclic # 10 % up to 100 % RH ±3% RH DIN EN 60068-2-38 DIN EN ISO 6270-2 AT / AHT Humidity # 95 % RH IPX7 / IPX8 Immersion test # at ambient temperature up to 25 m Pressure # up to 4 bar ±2% RH at 25°C up to 55°C - DIN EN 60529 ISO 20653 ±0,005 bar IP1X to IP4X Test probe # Test Force: ±10 % DIN EN 60529 ISO 20653 Vibration Sinusoidal / Frequency range # 5 Hz up to 2.000 Hz Frequency: ±1 Hz from 5 Hz up to 50 Hz; ±2 % over 50 Hz Acceleration reference point: ±15 % DIN EN 60068-2-6 Random Vibration / Frequency range # 5 Hz up to 2.000 Hz ±10 % grms DIN EN 60068-2-64 Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 - Translation - 6/7 Annex to the accreditation certificate D-PL-20258-01-00 Type of testing testing area / value range Measurement uncertainty limit deviation example standard Mechanical Shock # Acceleration: 5 g up to 50 g Shock duration: 2 ms up to 30 ms ±15 % m/s Combined Vibration & Temperature # -50°C up to +150°C ±2 K Frequency # 2 Hz up to 5.000 Hz ±2 % Acceleration # 0,1 m/s² up to 1.000 m/s² ±5 % Salt spray test # Ambient temperature (+5 K) up to +50°C ±2 K DIN EN ISO 9227 DIN EN 60068-2-11 DIN EN 60068-2-52 Condensation water atmosphere CH, AHT, AT # Ambient temperature (+5 K) up to +42°C ±3 K DIN EN ISO 6270-2 Visual inspection # Magnification ratio 8X up to 1000X Stereo Contact interruption # 1 µs, 10 µs Temperature rise # Current: 1 A up to 1000 A Temperature: 20°C up to 250°C Temperature: ±0,25 K Force, pull and push # 1 N up to 100 kN ±0,5 % Heat / Cold # -70°C up to +180°C - Period of validity: 2016-02-02 to 2021-02-01 Date of issue: 2016-02-02 DIN EN 60068-2-27 DIN EN 60512-1-1 Time: ±10 % DIN EN 60512-2-5 Current: ±1 % DIN EN 60512-5-1 DIN EN 60512-5-2 DIN EN 60512-10-4 DIN EN 60512-13-1 DIN EN 60512-13-2 ±2 K - Translation - DIN EN 60068-2-1 DIN EN 60068-2-2 7/7