Annex - DAkkS

advertisement
Deutsche Akkreditierungsstelle GmbH
Annex to the Accreditation Certificate D-PL-20258-01-00
according to DIN EN ISO/IEC 17025:2005
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
Holder of certificate:
Amphenol-Tuchel Electronics Gesellschaft mit beschränkter Haftung
Prüflaboratorium
August-Häusser-Straße 10, 74080 Heilbronn
Tests in the fields:
Electrical, mechanical and environmental simulation tests under inclusion of temperature,
humidity, corrosion, IP degree of protection, vibration and mechanical shock as well as
combinations thereof for the validation of connectors and other technical products
Within the scope of accreditation marked with *), the testing laboratory is permitted, without being
required to inform and obtain prior approval from DAkkS, to use standards or equivalent testing
methods listed here with different issue dates.
Within the given testing field marked with #), the testing laboratory is permitted, without being
required to inform and obtain prior approval from DAkkS, the following: the free choice of standard
or equivalent testing methods. The listed testing methods are exemplary. The testing laboratory
maintains a current list of all testing methods within the flexible scope of accreditation.
Testing field
Connectors *
Standard /
In-House Procedure /
Version
DIN EN 60512-11:2013-01
Title of Standard or In-House Procedure
(Deviations / Modifications of Standard)
Test Range /
Restrictions
Connectors for electronic equipment - Tests
and measurements - Part1-1: General
examination; Test1a: Visual examination
(IEC60512-1-1:2002
This document is a translation. The definitive version is the original German annex to the accreditation certificate.
1/7
Annex to the accreditation certificate D-PL-20258-01-00
Testing field
Standard /
In-House Procedure /
Version
Title of Standard or In-House Procedure
(Deviations / Modifications of Standard)
Connectors *
DIN EN 60512-21:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 2-1: Electrical
continuity and contact resistance tests; Test
2a: Contact resistance; Millivolt level
method (IEC 60512-2-1:2002)
Connectors *
DIN EN 60512-22:2004-01
Connectors for electronic equipment- Tests
and measurements- Part 2-2: Electrical
continuity and contact resistance tests –
Test 2b: Contact resistance - Specified test
current method (IEC 60512-2-2:2003)
Connectors *
DIN EN 60512-26:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 2-6: Electrical
continuity and contact resistance tests; Test
2f: Housing (shell) electrical continuity (IEC
60512-2-6:2002)
Connectors *
DIN EN 60512-31:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 3-1: Insulation
tests; Test 3a: Insulation resistance (IEC
60512-3-1:2002)
Connectors *
DIN EN 60512-41:2004-01
Connectors for electronic equipment - Tests
and measurements – Part 4-1: Voltage
stress tests – Test 4a: Voltage proof (IEC
60512-4-1:2003)
Connectors *
DIN EN 60512-51:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 5-1: Currentcarrying capacity tests; Test 5a:
Temperature rise (IEC 60512-5-1:2002);
Connectors *
DIN EN 60512-52:2003-01-
Connectors for electronic equipment - Tests
and measurements – Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002)
Connectors *
DIN EN 60512-63:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 6-3: Dynamic
stress tests; Test 6c: Shock (IEC 60512-63:2002)
Connectors *
DIN EN 60512-64:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 6-4: Dynamic
stress tests; Test 6d: Vibration (sinusoidal)
(IEC 60512-6-4:2002)
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
- Translation -
Test Range /
Restrictions
2/7
Annex to the accreditation certificate D-PL-20258-01-00
Testing field
Standard /
In-House Procedure /
Version
Title of Standard or In-House Procedure
(Deviations / Modifications of Standard)
Connectors *
DIN EN 60512-65:2003-01
Connectors for electronic equipment - Tests
and measurements – Part 5-2: Currentcarrying capacity tests; Test 5b: Currenttemperature derating (IEC 60512-5-2:2002)
Connectors *
DIN EN 60512-91:2010-12
Connectors for electronic equipment - Tests
and measurements- Part 9-1: Endurance
tests – Test 9a: Mechanical operation (IEC
60512-9-1:2010)
Connectors *
DIN EN 60512-92:2012-09
Connectors for electronic equipment - Tests
and measurements – Part 9-2: Endurance
tests - Test 9b: Electrical load and
temperature (IEC 60512-9-2:2011)
Connectors *
DIN EN 60512-95:2010-12
Connectors for electronic equipment - Tests
and measurements – Part -5: Endurance
tests – Test 9e: Current loading, cyclic (IEC
60512-9-5:2010)
Connectors *
DIN EN 60512-104:2004-06
Connectors for electronic equipment- Tests
and measurements – Part 10-4: Impact tests
(free components), static load tests and
overload tests - endurance tests and
overload tests – Test 10d: Electrical overload
(connectors) (IEC 60512-10-4:2003);
Connectors *
DIN EN 60512-111:1999-08
Electromechanical components for
electronic equipment - Basic testing
procedures and measuring methods – Part
11: Climatic tests; Section 1: Test 11a:
Climatic sequence (IEC 60512-11-1:1995)
Connectors *
DIN EN 60512-131:2006-11
Connectors for electronic equipment - Tests
and measurements – Part 13-2: Mechanical
operation tests – Test 13b: Insertion and
withdrawal forces (IEC 60512-13-2:2006
Connectors *
DIN EN 60512-132:2006-11
Connectors for electronic equipment - Tests
and measurements – Part 13-2: Mechanical
operation tests – Test 13b: Insertion and
withdrawal forces (IEC 60512-13-2:2006)
Connectors *
DIN EN 60512-135:2006-11
Connectors for electronic equipment - Tests
and measurements – Part 13-5: Mechanical
operation tests – Test 13e: Polarizing and
keying method (IEC 60512-13-5:2006)
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
- Translation -
Test Range /
Restrictions
Low pressure tests
exempted
3/7
Annex to the accreditation certificate D-PL-20258-01-00
Testing field
Standard /
In-House Procedure /
Version
Title of Standard or In-House Procedure
(Deviations / Modifications of Standard)
Test Range /
Restrictions
Connectors *
DIN EN 61984:200911
Connectors *
DIN EN 60352-2:2014- Solderless connections – Part 2: Crimped
04
connections - General requirements, test
methods and practical guidance (IEC 603522:2006)
Connectors *
DIN EN 60529:201409
Degrees of protection provided by
enclosures (IP Code) (IEC 60529:1989 +
A1:1999 + A2:2013)
Limited to:
Protection against
contact IP 1x up to
IP4x
Water tightness
IPx7 and IPx8
Degree of
protection *
ISO 20653:2013-02
Road vehicles - Degrees of protection (IP
code) - Protection of electrical equipment
against foreign objects, water and access
Limited to:
Protection against
contact IP 1x up to
IP4x
Water tightness
IPx7 and IPx8
Connectors
VW 75174:2010-04
Climatic Testing *
Motor vehicle connectors – Test
specification
DIN EN 60068-2-31
DIN EN 60512-1114
DIN EN 60512-14-5
DIN EN 60068-2-13
DIN EN 60512-15-6
DIN EN 60512-1-2
DIN EN 60512-1-3
DIN EN 60512-1-4
DIN 40050-9
Connectors
Climatic
Testing *#
VW 75174-2:2008-01
Motor vehicle connectors - Slow-Motion
Test
Exempted Mixed
flowing gastest (
MFG 4)
Connectors
Climatic
Testing *#
VW 60330:2013-12
Crimped connections
Solderless electrical connections
Exempted DIN EN
60512-16-8
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
Connectors- Safety requirements and tests
(IEC 61984:2008)
- Translation -
4/7
Annex to the accreditation certificate D-PL-20258-01-00
Testing field
Standard /
In-House Procedure /
Version
Title of Standard or In-House Procedure
(Deviations / Modifications of Standard)
Test Range /
Restrictions
Environmental DIN EN 60068-2Simulation*# 1:2008-01
Environmental testing – Part 2-1: Tests – Test A:
Cold (IEC 60068-2-1:2007)
Environmental DIN EN 60068-2Simulation*# 2:2008-05
Environmental testing – Part 2-2: Tests – Test B:
Dry heat (IEC 60068-2-2:2007)
Environmental DIN EN 60068-2Simulation*# 6:2008-10
Environmental testing- Part 2-6: Tests - Test Fc:
Vibration (sinusoidal) (IEC 60068-2-6:2007)
Environmental DIN EN 60068-2Simulation*# 11:2000-02
Environmental testing – Part 2: Tests; test Ka: Salt
mist (IEC 60068-2-11:1981)
Environmental DIN EN 60068-2Simulation*# 14:2010-04
Environmental testing – Part 2-14: Tests – Test N:
Change of temperature (IEC 60068-2-14:2009)
Environmental DIN EN 60068-2Simulation*# 27:2010-02
Environmental testing – Part 2-27: Tests – Test Ea
and guidance: Shock (IEC 60068-2-27:2008)
Environmental DIN EN 60068-2Simulation*# 30:2006-06
Environmental testing – Part 2-30: Tests – Test Db:
Damp heat, cyclic (12h + 12h cycle) (IEC 60068-230:2005)
Environmental DIN EN 60068-2Simulation*# 38:2010-06
Environmental testing – Part 2-38: Tests – Test
Z/AD: Composite temperature/humidity cyclic test
(IEC 60068-2-38:2009)
Environmental DIN EN 60068-2Simulation*# 52:1996-10
Environmental testing – Part 2: Tests, Test Kb: Salt
mist, cyclic (sodium chloride solution) (IEC 600682-52:1996)
Environmental DIN EN 60068-2Simulation*# 61:1993-12
Environmental testing; part 2: test methods; test Low pressure
Z/ABDM: climatic sequence (IEC 60068-2-61:1991) tests exempted
Environmental DIN EN 60068-2Simulation*# 64:2009-04
Environmental testing – Part 2-64: Tests – Test Fh:
Vibration, broadband random and guidance (IEC
60068-2-64:2008);
Environmental DIN EN 60068-2Simulation*# 78:2014-02
Environmental testing – Part 2-78: Tests - Test Cab:
Damp heat, steady state (IEC 60068-2-78:2012)
Corrosion*#
DIN EN ISO
9227:2012-09
Corrosion tests in artificial atmospheres - Salt
spray tests (ISO 9227:2012)
Only NSS
Corrosion*#
ASTM B 117:2011
Standard Practice for Operating Salt Spray (Fog)
Apparatus
Only NSS
Corrosion*#
DIN EN ISO 62702:2005-09
Paints and varnishes - Determination of resistance
to humidity – Part 2: Procedure for exposing test
specimens in condensation-water atmospheres
(ISO 6270-2:2005);
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
- Translation -
5/7
Annex to the accreditation certificate D-PL-20258-01-00
Type of testing
testing area /
value range
Measurement
uncertainty
limit deviation
example standard
Heat / Cold #
-70°C up to +180°C
-
±2 K
DIN EN 60068-2-1
DIN EN 60068-2-2
Temperature Change #
-70°C up to +180°C
-
±2 K
DIN EN 60068-2-14 Nb
Temperature Shock #
70°C up to +180°C
-
±2 K
DIN EN 60068-2-14 Na
Temperature #
70°C up to +180°C
±0,25 K
-
-
Humidity #
10 % up to 100 %
RH
±3% RH
DIN EN 60068-2-78
DIN EN ISO 6270-2
CHT
Temperature Humidity
cyclic #
10 % up to 100 %
RH
±3% RH
DIN EN 60068-2-38
DIN EN ISO 6270-2 AT
/ AHT
Humidity #
95 % RH
IPX7 / IPX8
Immersion test #
at ambient
temperature
up to 25 m
Pressure #
up to 4 bar
±2% RH at
25°C up to
55°C
-
DIN EN 60529
ISO 20653
±0,005 bar
IP1X to IP4X
Test probe #
Test Force:
±10 %
DIN EN 60529
ISO 20653
Vibration Sinusoidal /
Frequency range #
5 Hz up to 2.000 Hz
Frequency:
±1 Hz from 5 Hz
up to 50 Hz;
±2 % over 50 Hz
Acceleration
reference point:
±15 %
DIN EN 60068-2-6
Random Vibration /
Frequency range #
5 Hz up to 2.000 Hz
±10 % grms
DIN EN 60068-2-64
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
- Translation -
6/7
Annex to the accreditation certificate D-PL-20258-01-00
Type of testing
testing area /
value range
Measurement
uncertainty
limit deviation
example standard
Mechanical Shock #
Acceleration:
5 g up to 50 g
Shock duration:
2 ms up to 30 ms
±15 % m/s
Combined Vibration &
Temperature #
-50°C up to +150°C
±2 K
Frequency #
2 Hz up to 5.000 Hz
±2 %
Acceleration #
0,1 m/s² up to
1.000 m/s²
±5 %
Salt spray test #
Ambient
temperature
(+5 K) up to +50°C
±2 K
DIN EN ISO 9227
DIN EN 60068-2-11
DIN EN 60068-2-52
Condensation water
atmosphere
CH, AHT, AT #
Ambient
temperature
(+5 K) up to +42°C
±3 K
DIN EN ISO 6270-2
Visual inspection #
Magnification ratio
8X up to 1000X
Stereo
Contact interruption #
1 µs, 10 µs
Temperature rise #
Current:
1 A up to 1000 A
Temperature:
20°C up to 250°C
Temperature:
±0,25 K
Force, pull and push #
1 N up to 100 kN
±0,5 %
Heat / Cold #
-70°C up to +180°C
-
Period of validity: 2016-02-02 to 2021-02-01
Date of issue: 2016-02-02
DIN EN 60068-2-27
DIN EN 60512-1-1
Time:
±10 %
DIN EN 60512-2-5
Current:
±1 %
DIN EN 60512-5-1
DIN EN 60512-5-2
DIN EN 60512-10-4
DIN EN 60512-13-1
DIN EN 60512-13-2
±2 K
- Translation -
DIN EN 60068-2-1
DIN EN 60068-2-2
7/7
Download