Vol. 6 Modified Products Discontinued Products New Products

advertisement
Vol. 6
New Products
Reversing standard type contactors SC-E series ........................................................................................ 2
Manual motor starters Power supply terminal covers .................................................................................. 5
22mm-dia. emergency stop pushbutton switches AR22 series .................................................................... 6
22mm-dia. emergency stop pushbutton switches AM22 series ................................................................... 8
Display lights DP36 and 40 series ............................................................................................................. 10
Power terminal blocks SKT series .............................................................................................................. 12
AC voltage and current transducers WT2AC series ................................................................................... 14
Arresters for low voltage circuit CN233 series ........................................................................................... 16
AC power distribution monitoring unit for one feeder, F-MPC04 series and CC2D CTs ............................. 18
Modified Products
Miniature control relays / HH52, HH54 series ............................................................................................. 22
Miniature control relays / Sockets for rail mounting ..................................................................................... 22
Display lights and multi display lights .......................................................................................................... 23
Manual motor starters / BM3 series ............................................................................................................ 23
Discontinued Products
AS-Interface Waterproof connector-type slave module FM6D, FM6B ....................................................... 24
AS-Interface Power supply FP1B-JNW213 .............................................................................................. 24
AS-Interface DeviceNet/AS-i gateway FC2L-DL ...................................................................................... 24
TIME006
New
Products
Reversing standard type contactors
SC-E series
Ideal for reversing 3-phase induction motors
Features
• Designed for the forward-reverse operation and plugging
stop of 3-phase induction motors.
• Mechanical interlock mechanism provided
• Snap-on 35mm top hat rail mounting
KK03-047
KK03-040
Reversing contactor
SC-E3RM
Power connection kits
SZ-ERW1/A + SZERW1/B
Types and ratings
• AC operated
Rated operational current (A)
Rated thermal Auxiliary contact arrangement
Frame Motor rating (kW)
3-phase (AC-3)
size
3-phase (AC-3)
Resistive load (AC-1) current (A)
200-240V 380-440V 200-240V 380-440V 200-240V 380-440V
9
4
9
20
20
(1NO+1NC) x 2, 2NC x 2
E02
2.2
20
(3NO+1NC) x 2, (2NO+2NC) x 2
12
5.5
12
20
20
(1NO+1NC) x 2, 2NC x 2
E03
3
20
(3NO+1NC) x 2, (2NO+2NC) x 2
18
7.5
18
25
25
(1NO+1NC) x 2, 2NC x 2
E04
4
25
(3NO+1NC) x 2, (2NO+2NC) x 2
25
11
25
32
32
(1NO+1NC) x 2, 2NC x 2
5.5
E05
32
(3NO+1NC) x 2, (2NO+2NC) x 2
32
15
32
50
(1NO+1NC) x 2, 2NC x 2
50
7.5
E1
50
(3NO+1NC) x 2, (2NO+2NC) x 2
40
18.5
40
60
(1NO+1NC) x 2, 2NC x 2
60
11
E2
60
(3NO+1NC) x 2, (2NO+2NC) x 2
50
22
50
65
(1NO+1NC) x 2, 2NC x 2
65
15
E2S
65
(3NO+1NC) x 2, (2NO+2NC) x 2
65
30
68
100
(1NO+1NC) x 2, 2NC x 2
100
18.5
E3
100
(3NO+1NC) x 2, (2NO+2NC) x 2
80
40
80
150
(1NO+1NC) x 2, 2NC x 2
150
22
E4
150
(3NO+1NC) x 2, (2NO+2NC) x 2
105
55
105
150
(2NO+2NC) x 2
150
30
E5
150
125
60
125
150
(2NO+2NC) x 2
150
37
E6
150
150
75
150
200
(2NO+2NC) x 2
200
45
E7
200
Notes: • Ratings conform to IEC standard
• The above types are shipped in a set containing two magnetic contactors,
one SZ-RM mechanical interlock unit, two front mounting auxiliary
contact blocks, and electrical interlock wiring. The power connection kit
for the reversing contactor is sold separately.
Type
SC-E02RM *
SC-E03RM *
SC-E04RM *
SC-E05RM *
SC-E1RM *
SC-E2RM *
SC-E2SRM *
SC-E3RM *
SC-E4RM *
SC-E5RM
SC-E6RM
SC-E7RM
• To prevent short-circuit faults when using SC-E02RM to SC-E04RM types
for high-speed switching, provide a time delay relay or other electrical
interlock to ensure that the switching time is 15ms min.
* Equipped with the SZ-A11/T, SZ-A02/T, SZ-A31/T, or SZ-A22/T front
mounting auxiliary contact block.
• DC operated
DC reversing magnetic contactors are also available.
Further
Information
2
Contact FUJI .
FUJI ED & C TIMES Vol. 6
Reversing standard type contactors SC-E series
New Products
• Power connection kits for reversing
Used with
Power connection kit
Type
SZ-ERW1/A (Line side)
SZ-ERW1/B (Load side)
SZ-ERW1/D (Load side)
SZ-ERW2/A (Line side)
SZ-ERW2/B (Load side)
SZ-ERW2/D (Load side)
SZ-ERW3/A (Line side)
SZ-ERW3/B (Load side)
SZ-ERW3/D (Load side)
Used with
Power connection kit
Type
SZ-ERW4/A (Line side)
SZ-ERW4/B (Load side)
SZ-ERW5/A (Line side)
SZ-ERW5/B (Load side)
SZ-ERW6/A (Line side)
SZ-ERW6/B (Load side)
SC-E02 to SC-E05
SC-E02/G to SC-E05/G
SC-E1 to E2S
SC-E1/G to E2S/G
SC-E5
SC-E6
SC-E7
SC-E3, E4
SC-E3/G, E4/G
Dimensions, mm
wiring diagrams
• AC operated
(1NO+1NC) x 2
SC-E02RM, 03RM, 04RM, 05RM
119 (Rail height 15)
109
92
61
8.5
99
56
Panel drilling
1/L13/L2 5/L3 53 61
2/T14/T2 6/T354 62
21
35
2/T14/T2 6/T3 54 62
20
35
A1 A2
14.5
Coil terminal
M3.5
Auxiliary
terminal
M3.5
1/L13/L2 5/L3 53 61
A1 A2
Main
terminal
1/L13/L2 5/L3 51 61
60
81
49
28
70.5
2NC x 2
1/L13/L2 5/L3 51 61
A1 A2
2/T14/T2 6/T352 62
7.7
A1 A2
2/T14/T2 6/T3 52 62
10.5
10
Mass: 0.8kg (4-aux. contacts)
0.77kg (2-aux. contacts)
13
Mounting hole
4-M4
(2NO+2NC) x 2
1/L13/L2 5/L3 53 61 71 83
Panel drilling
134 (Rail height 15)
124
Main
terminal
107
2/T14/T2 6/T354 62 72 84
A1 A2
2/T14/T2 6/T3 54 62 72 84
Coil terminal
M3.5
121
67
45
45
22
(3NO+NC) x 2
18.5
2
9.5
65.5
10.5
1/L13/L2 5/L3 53 61 71 83
A1 A2
SC-E1RM, E2RM, E2SRM
1/L13/L2 5/L3 53 61 73 83
1/L13/L2 5/L3 53 61 73 83
A1 A2
Auxiliary
terminal
M3.5
75
90
57
28
86
A1 A2
2/T14/T2 6/T3 54 62 74 84
67
16.5
7.7
2/T14/T2 6/T354 62 74 84
10
Mounting hole
4-M4
Mass: 1.3kg (4-aux. contacts)
1.27kg (2-aux. contacts)
SC-E3RM, E4RM
149 (Rail height 15)
139
121
147
80
Main
terminal
Panel drilling
(54 to)60
23
Auxiliary
terminal
M3.5
Mass: 2.24kg (4-aux. contacts)
2.21kg (2-aux. contacts)
FUJI ED & C TIMES Vol. 6
7.7
20.5
10
13
(54 to)60
90
77
112
28
108
19.5
72.5
10.5
2.5
Coil terminal
M3.5
80
Mounting hole
4-M4
3
New Products Reversing standard type contactors SC-E series
Dimensions, mm
wiring diagrams
• AC operated
(1NO+1NC) x 2
SC-E5RM
Main
terminal
137
1/L13/L2 5/L3 53 61
Coil terminal
M3.5
200
32
A1 A2
111
2/T14/T2 6/T354 62
2/T14/T2 6/T3 54 62
7.5
4
10.5
1.6
1/L13/L2 5/L3 53 61
A1 A2
230
82
2NC x 2
1/L13/L2 5/L3 51 61
A1 A2
165
150
129
155
1/L13/L2 5/L3 51 61
2/T14/T2 6/T352 62
A1 A2
2/T14/T2 6/T3 52 62
(2NO+2NC) x 2
Mounting hole
3-M5
Auxiliary terminal M3.5
1/L13/L2 5/L3 53 61 71 83
Mass : 4.64kg
1/L13/L2 5/L3 53 61 71 83
A1 A2
2/T14/T2 6/T354 62 72 84
A1 A2
2/T14/T2 6/T3 54 62 72 84
SC-E6RM
Main
terminal
1.6
32
4
Coil terminal
M3.5
250
220
83
123
7.5
145
(3NO+NC) x 2
1/L13/L2 5/L3 53 61 73 83
1/L13/L2 5/L3 53 61 73 83
A1 A2
16
A1 A2
Mounting hole 3-M5
2/T14/T2 6/T3 54 62 74 84
190
175
143
169.5
2/T14/T2 6/T354 62 74 84
Auxiliary terminal M3.5
Mass : 5.8kg
• SC-E7RM
Main terminal
290
4
260
138
84
35
Mass : 6.8kg
4
Mounting hole
3-M6
215
200
146
175
27
2
Coil terminalM3.5
7.5
147
Auxiliary terminal M3.5
FUJI ED & C TIMES Vol. 6
New
Products
Manual motor starters
Power supply terminal covers
New power supply terminal covers allow UL508
Type E and UL508 Type F applications for MMSs
Features
• Combining the BZ0TCRE power supply terminal cover and
BZ0TKUAB short-circuit alarm contact block in a FUJI
BM3R series manual motor starter (MMS) allows it to be
used as a manual self-protected combination controller
(Type E combination motor controller). In the BM3V series,
the BZ0TCRE power supply terminal cover is not necessary
to fulfill the UL489 insulation distance requirement.
• Combining the BZ0TCRE power supply terminal cover and
BZ0TKUAB short-circuit alarm contact block in a
combination starter formed by a BM3R MMS and an SCseries magnetic contactor allows it be used as a selfprotected combination controller (Type F combination motor
controller). In the BM3V series, the BZ0TCRE power supply
terminal cover is not necessary to fulfill the UL489 insulation
distance requirement.
Type E advantages
• Since the Type E can be used for branch circuit protection
(BCP) as stipulated in NEC 430.52(c)(6), there is no need to
provide upstream UL489-approved BCPs as short-circuit
protection for motor branching circuits. Ordinarily, a
separate BCP is necessary for each motor.
• It takes up less space inside the control panel.
Note: Using Type E to eliminate the need for a BCP applies
only to motor load circuits. It cannot be applied to other
loads, such as resistance load and lamp load circuits.
Power supply terminal cover
BZ0TCRE
MMS with BZ0TCRE
Type F advantages
• By including a compliant MMS in the Type E and applying it
as a BCP as stipulated in NEC 430.52(c)(6), there is no
need to provide upstream UL489-approved BCPs as shortcircuit protection for motor branching circuits. Ordinarily, a
separate BCP is necessary for each motor.
• It takes up less space inside the control panel.
Note: Using Type F to eliminate the need for a BCP applies
only to motor load circuits. It cannot be applied to other
loads, such as resistance load and lamp load circuits
Type: BZ0TCRE
Dimensions, mm
10.5
8
3-ø7.5
1 L1
3 L2
5 L3
1 L1
3 L2
5 L3
45
13
8
10.8
5.4
55.5
10.5
35.5
FUJI ED & C TIMES Vol. 6
5
New
Products
22mm-dia. emergency stop
pushbutton switches AR22 series
Integrated operator/contact block improves
reliability.
Features
• Reliability of safety functions increased by integrated
operator/contact block construction.
• LED (24V AC/DC) and neon (110V, 120V, 220V, 240V AC)
illuminated types available, with interconnected lamp circuit
that turns the lamp on when the contacts are closed.
• White arrow on red button clearly indicates push-lock/turnreset direction.
• Combination of AU-flashed Ag contacts and sliding
mechanism ensures high contact reliability.
• Terminal cover for protection degree IP2X increases worker
safety by preventing fingers from accidentally touching
charged parts.
• FUJI original trigger action mechanism stops contacts from
operating until the button is locked, to prevent accidental
pressing by a person or object.
• Forced contact opening mechanism securely breaks the
circuit even during errors, such as the partial welding of 1NC
contacts.
• Conforms to international standards, including UL/CSA and
EN European Standards (TÜV), and bears CE markings.
KK03-037
AR22VGE
Emergency stop
pushbutton switch
KK03-036
AR22VGF
Emergency stop
illuminated pushbutton switch
Types and ratings
• Emergency stop pushbutton switches EN418
Forced contact opening and trigger action mechanisms
Operator
40mm dia.
Push-lock, turn-reset
Contact arrangement
1NC
1NO+1NC
2NC
Type
AR22VGE-01R
AR22VGE-11R
AR22VGE-02R
Button color
Red
• Emergency stop illuminated pushbutton switches EN418
Forced contact opening and trigger action mechanisms
Operator
40mm dia.
Push-lock, turn-reset
Type of lamp
LED lamp
Full-voltage type
Lamp voltage
24V AC/DC
Neon lamp
Full-voltage type
110V AC: H
120V AC: K
220V AC: M
240V AC: P
Contact arrangement
1NC
1NO+1NC
2NC
1NC
1NO+1NC
2NC
Type
AR22VGF-01E3R
AR22VGF-11E3R
AR22VGF-02E3R
AR22VGF-01 1R
AR22VGF-11 1R
AR22VGF-02 1R
Button color
Red
Red
Note: • Replace the mark by the lamp voltage code. 110V AC: H, 120V AC: K, 220V AC: M, 240V AC: P
• Lamp contacts are built-in, and switch operation and lamp circuit are interconnected. When current is
applied to the lamp circuit, the lamp turns on as soon as the contacts are colsed.
6
FUJI ED & C TIMES Vol. 6
22mm-dia. emergency stop pushbutton switch AR22 series
Specifications
New Products
Contact ratings
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R500281370001)
Rated insulation voltage Ui
Durability Mechanical
Electrical
Operating frequency
Withstand voltage
Insulation resistance
Vibration
250V AC/DC
Min. 100000 operations
Min. 100000 operations
1800 operations/hour (on-load factor 40%)
2500V AC 1minute
100MΩ (500V DC megger)
Malfunction durability:
10-55Hz double amplitude 0.1mm
Mechanical durability:
16.7Hz double amplitude 3.0mm
Malfunction durability: 150m/s2
Shock
Mechanical durability: 500m/s2
Operating -20 to +60°C (Illuminated type: -20 to +50°C)
Ambient
temperature
No icing, no condensation
Storage
-40 to +80°C
45 to 85%RH (at -5 to +40°C)
Humidity (in box)
No icing, no condensation
IEC 60529: IP65
Operator protection
degree
JEM 1030: IP65f
Terminal protection degree IEC 60529: IP2X
Rated operational current le (A)
Rated
Rated
DC
operational
AC
thermal
current Ith (A) voltage Ue (V) AC15 (Ind. load) DC13 (Ind. load)
1.5
24
6
10
—
3
120
0.3
—
125
—
3
240
0.15
—
250
UL and CSA
• AC (COSø=0.35)
Contact
rating code
B300
Break (A)
3
240V
Make (A)
15
Break (A)
1.5
• DC (Time constant T0.95=6P)
Contact
rating code
Q300
Operating characteristics
125V
Make/Break (A)
0.55
250V
Make/Break (A)
0.27
Standards
UL508
CSA C22.2 No. 14
EN60947-5-1
EN60947-5-5
Push-lock, turn-reset
26N
Approx. 10mm
Approx. 45°
Approx. 0.2N•m
Operator
Required operating force
Operating stroke
Resetting operation angle
Required resetting force
120V
Make (A)
30
File No. E44592 (UL Recognized)
File No. E44592 (c-UL Recognized)
TÜV licence No. R500281370001
Dimensions, mm
57
Terminal cover
32
40
55
ø30
Terminal No. 3 (21)
Terminal No. 1 (11)
Terminal No. 4 (22)
Terminal No. X1
Nut
3
Terminal No. 2 (12)
4
Lamp terminal screw M3.5
(Illuminated type only)
Terminal screw M3.5
Terminal No. X2
Spring washer
Packing
Panel thickness
1 to 6
Note: Terminal No. shown in ( ) are for contact arrangement 2NC.
FUJI ED & C TIMES Vol. 6
7
New
Products
22mm-dia. emergency stop
pushbutton switches AM22 series
Emergency stop pushbutton switches with locking
nut on the front panel.
Features
• White arrow on red button clearly indicates push-lock/turnreset direction.
• FUJI original trigger action mechanism stops contacts from
operating until the button is locked, to prevent accidental
pressing by a person or object.
• Forced contact opening mechanism securely breaks the
circuit even during errors, such as the partial welding of 1NC
contacts.
• Conforms to international standards, including UL/CSA and
EN European Standards (TÜV), and bears CE markings.
KK02-236
AM22V0E
Emergency stop
pushbutton switch
KK02-240, 239
AM22V0F
Emergency stop
illuminated pushbutton switch
Types and ratings
Emergency stop pushbutton switches EN418
Forced contact opening and trigger action mechanisms
Operator
40mm dia.
Push-lock, turn-reset
29mm dia.
Push-lock, turn-reset
Contact
arrangement
1NC
1NO+1NC
2NC
3NC
2NO+2NC
4NC
1NC
1NO+1NC
2NC
3NC
2NO+2NC
4NC
Type
AM22V0E-01R
AM22V0E-11R
AM22V0E-02R
AM22V0E-03R
AM22V0E-22R
AM22V0E-04R
AM22VSE-01R
AM22VSE-11R
AM22VSE-02R
AM22VSE-03R
AM22VSE-22R
AM22VSE-04R
Button
color
Red
Emergency stop illuminated pushbutton switches EN418
Forced contact opening and trigger action mechanisms
Operator
Transformer
LED lamp
Lamp voltage Contact
arrangement Type
40mm dia. Without 24V AC/DC
Push-lock,
turn-reset
With
110V AC: H
220V AC: M
Red
29mm dia. Without 24V AC/DC
Push-lock,
turn-reset
With
Notes: • Up to 4-contact blocks are available.
• NO contact is used for overlap contact.
110V AC: H
220V AC: M
Transparent Without 24V AC/DC
colored
40mm dia.
Push-lock,
turn-reset With
Note: Replace the
110V AC: H
220V AC: M
1NC
1NO+1NC
2NC
3NC
1NC
1NO+1NC
2NC
1NC
1NO+1NC
2NC
3NC
1NC
1NO+1NC
2NC
1NC
1NO+1NC
2NC
3NC
1NC
1NO+1NC
2NC
mark by the lamp voltage code.
Button
color
AM22V0F-01E3R Red
AM22V0F-11E3R
AM22V0F-02E3R
AM22V0F-03E3R
AM22V0F-01 3R
AM22V0F-11 3R
AM22V0F-02 3R
AM22VSF-01E3R
AM22VSF-11E3R
AM22VSF-02E3R
AM22VSF-03E3R
AM22VSF-01 3R
AM22VSF-11 3R
AM22VSF-02 3R
AM22VDF-01E3R
AM22VDF-11E3R
AM22VDF-02E3R
AM22VDF-03E3R
AM22VDF-01 3R
AM22VDF-11 3R
AM22VDF-02 3R
110V AC: H, 220V AC: M
• LED lamp voltage
Lamp Full-voltage With transformer
voltage 6V
24V 110V 127V 220V 254V 380V 440V 480V 550V
AC AC/DC AC AC AC AC AC AC AC AC
W
V
T
S
Q
M
Code A
E
L
H
Notes: • 6V AC LED lamp is used for the separate mounting transformer.
• NO contact is used for overlap contact.
• Switch operation and lamp circuit are not interconnected.
8
FUJI ED & C TIMES Vol. 6
22mm-dia. emergency stop pushbutton switch AM22 series
Specifications
New Products
Contact ratings
10A
600V AC/DC
(Illuminated full-voltage type 250V AC/DC)
Min. 300000 operations
Min. 300000 operations
1200 operations/hour (on-load factor 40%)
2500V AC 1minute
100MΩ (500V DC megger)
Malfunction durability:
10-55Hz double amplitude 0.1mm
Mechanical durability:
16.7Hz double amplitude 3.0mm
Malfunction durability: 150m/s2
Shock
Mechanical durability: 500m/s2
Operating -20 to +60°C (Illuminated type: -20 to +50°C)
Ambient
temperature
No icing, no condensation
Storage
-40 to +80°C
45 to 85%RH (at -5 to +40°C)
Humidity (in box)
No icing, no condensation
IEC 60529: IP65
Operator protection
degree
JEM 1030: IP65f
Rated thermal current
Rated insulation voltage
Ui
Durability Mechanical
Electrical
Operating frequency
Withstand voltage
Insulation resistance
Vibration
Operating characteristics
JIS C 8201-5-1, IEC 60947-5-1, EN 60947-5-1 (TÜV R50028146)
Rated operational voltage
Ue (V)
24
120
125
240
250
480
600
Rated operational current le (A)
DC
AC
DC13 (Ind. load)
AC15 (Ind. load)
2
6
—
6
0.65
—
—
6
0.23
—
—
2.5
—
2
UL and CSA
• AC (COSø=0.35)
240V
480V
600V
Contact 120V
Make Break Make Break Make Break Make Break
rating
code
(A)
(A)
(A)
(A)
(A)
(A)
(A)
(A)
60
30
15
12
6
3
1.5
1.2
A600
• DC (Time constant T0.95=6P)
250V
Make/Break
(A)
0.27
Contact 125V
Make/Break
rating
code
(A)
0.55
Q600
300-600V
Make/Break
(A)
0.1
Push-lock, turn-reset
Approx. 23N
Approx. 9mm
Approx. 60°
Approx. 0.25N•m
Operator
Required operating force
Operating stroke
Resetting operation angle
Required resetting force
Standards
File No. E 44592 (UL Listed)
File No. LR 20479
TÜV licence No. R50028146
UL508
CSA C22.2 No.14
EN 60947-5-1
EN 60947-5-5
Dimensions, mm
ø40
1
30
59.5(63.5 *1)
ø40
32.5
30
39.5
24.5 *1
37
Terminal screw M3.5
44
32.5
39.5
37
44
59.5
37
1
Terminal cover
• 40mm dia. push-lock, turn-reset with transformer
AM22V0F
37
• 40mm dia. push-lock, turn-reset
AM22V0E
ø16
Terminal screw M3.5
Packing
Nut
Operation angle: 60°
Panel
thickness
1 to 6
Terminal cover
Packing
Transformer
Panel
thickness
1 to 6
Nut
ø16
Operation angle: 60°
Note: *1 Dimensions for the types with transformers of
the lamp voltages 254V to 550V AC.
FUJI ED & C TIMES Vol. 6
9
New
Products
Display lights
DP36 and 40 series
New design with high-brightness LED and self-lifting
terminal improves safety and working conditions.
Features
• Employs high-brightness LED
• New LED lamp significantly reduces power consumption and
mass.
• Reduces wiring work and improves safety by integrating the
FUJI self-lifting terminal (quick mounting terminal) and
terminal cover
• LED lamp incorporates a circuit to prevent lighting errors.
• Modular design of LED unit allows easy changes in colors
and color arrangement (two- and three-split rectangular
illumination faces).
• Can be used with film legend plates.
• Ideal for side-by-side mounting
KK03-072A
DP36 series
Types and ratings
• DP36 series (LED lamp)
Shape of illumination face
Illumination
type
Voltage input
type
Lamp voltage
Type
Square, 36x36mm
Full face
Full voltage
With resistor unit
12V AC/DC
24V AC/DC
100 to 110V AC/DC
DP36S1NDP36S1NDP36S1N-
B3
E3
H3
With CR unit
200 to 220V AC/DC
DP36S1N-
M3
Full face
Full voltage
2-split face
With resistor unit
With CR unit
Full voltage
3-split face
With resistor unit
With CR unit
Full voltage
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
DP36T1NDP36T1NDP36T1NDP36T1NDP36T2NDP3612NDP36T2NDP36T2NDP36T3NDP36T3NDP36T3NDP36T3N-
B3
E3
H3
M3
B3
E3
H3
M3
B3
E3
H3
M3
DP36S1N
Rectangular, 36x72mm
DP36T1N
DP36T3N
With resistor unit
With CR unit
Specify the illumination
color code in the
mark.
Red: R
Green: G
Yellow: Y
Orange: A
White: W
Blue: S
Snow-white: P
Notes: • Voltages other than above are available.
• DP36S1N, T1N and T2N with check terminals are also available.
10
FUJI ED & C TIMES Vol. 6
Display lights DP36 and 40 series
New Products
• DP40 series (LED lamp)
Shape of illumination face
Illumination
type
Voltage input
type
Lamp voltage
Type
Square, 40x40mm
Full face
Full voltage
With resistor unit
12V AC/DC
24V AC/DC
100 to 110V AC/DC
DP40S1NDP40S1NDP40S1N-
B3
E3
H3
With CR unit
200 to 220V AC/DC
DP40S1N-
M3
Full face
Full voltage
2-split face
With resistor unit
With CR unit
Full voltage
3-split face
With resistor unit
With CR unit
Full voltage
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
12V AC/DC
24V AC/DC
100 to 110V AC/DC
200 to 220V AC/DC
DP40T1NDP40T1NDP40T1NDP40T1NDP40T2NDP4012NDP40T2NDP40T2NDP40T3NDP40T3NDP40T3NDP40T3N-
B3
E3
H3
M3
B3
E3
H3
M3
B3
E3
H3
M3
DP40S1N
Rectangular, 40x80mm
DP40T1N
With resistor unit
With CR unit
DP40T3N
Specify the illumination
color code in the
mark.
Red: R
Green: G
Yellow: Y
Orange: A
White: W
Blue: S
Snow-white: P
Notes: • Voltages other than above are available.
• DP36S1N, T1N and T2N with check terminals are also available.
Dimensions, mm
• DP36 series
Panel cutting
• Square, 36x36mm
8
61
+0.6
Terminal screw M3.5
31 –0.5
+0.6
X1
12.8
30 sq.
8
31 –0.5
36 sq.
X2
Panel thickness: 1 to 6
Mass: 42g
3-split face type
66
36
X1
X2
X2
X3
X2
X4
X5
X6
30
8
8
Terminal screw M3.5
Panel thickness: 1 to 6
X1
+0.6
–0.5
X1
+0.6
67 –0.5
12.8
61
36
8
66
36
12.8
72
31
• Rectangular, 36x72mm
Mass: 86g
Mass: 103g
• DP40 series
• Square, 40x40mm
8
61
35 +10
Terminal screw M3.5
X1
+1
0
12.8
34.5 sq.
8
35
40 sq.
X2
Panel thickness: 1 to 6
Mass: 48g
3-split face type
74.5
48
X2
X2
X1
X1
X1
X2
X2
X2
8
8
Terminal screw M3.5
Panel thickness: 1 to 6
FUJI ED & C TIMES Vol. 6
Mass: 96g
+1
0
X1
12.8
X1
75 +10
12.8
40
74.5
36
61
34.5
8
80
35
• Rectangular, 40x80mm
Mass: 114g
11
New
Products
Power terminal blocks
SKT series
Further improving the efficiency and ease of wiring
and inspections
Features
• Transparent terminal cover allows the wiring configuration to
be checked externally.
• Slotted hexagon head bolts that can be tightened with
screwdrivers or box wrenches are used for the terminals.
• The line side and load side are provided with hinged
terminal covers to ensure safety and allow easier
maintenance and inspections.
• cUL approved, file No. E45457
SKT14A-3C to SKT100A3C only.
AF01-220
SKT14A-3C
Types and ratings
• Terminal blocks
Pole
Rated insulation
voltage (V AC)
Rated continuous
current (A)
3
600
3 + 1 (Earth terminal)
600
50
100
150
200
50
100
150
200
Applicable cable size
(mm2)
2 to 14
2 to 38
14 to 60
30 to 100
2 to 14
2 to 38
14 to 60
30 to 100
Type
SKT14A-3C
SKT38A-3C
SKT60A-3C
SKT100A-3C
SKT14A-3CG
SKT38A-3CG
SKT60A-3CG
SKT100A-3CG
• Connectors
Rated insulation voltage
(V AC)
600
Rated continuous current
(A)
50
100
150
200
400
400
200
Specifications
Insulation resistance
Withstand voltage
Ambient temperature
Humidity
Flammability
Temperature rise
12
Applicable cable size
(mm2 )
2 to 14
2 to 38
14 to 60
30 to 100
80 to 200
80 to 200
30 to 80
Type
SKT14-S
SKT38-S
SKT60-S
SKT100-S
SKT200-S
SKT200-SD
Tightening torque
100MΩ or more (500V DC megger)
2500V AC 1minute
-20 to +55°C
85%RH or less
UL94V-2 (Cover)
45K or less (JIS C 2811)
Type
SKT14A-3C
SKT14A-3CG
SKT38A-3C
SKT38A-3CG
SKT60A-3C
SKT60A-3CG
SKT100A-3C
SKT100A-3CG
Recommended tightening
torque (N•m)
Line side
4.5–5.0
(M6)
4.5–5.0
(M6)
9–10
(M8)
15–20
(M10)
Load side
11.5–15.5
(14mm2, M8)
11.5–15.5
(38mm2, M8)
11.5–15.5
(60mm2, M8)
23–31
(100mm2, M10)
Cable pull-out
min. force (N)
Min. cable
222
(2mm2)
222
(2mm2)
311
(14mm2)
311
(30mm2)
Max. cable
400
(14mm2)
445
(38mm2)
623
(60mm2)
801
(100mm2)
FUJI ED & C TIMES Vol. 6
Power terminal blocks SKT series
New Products
Dimensions, mm
• Terminal block
SKT14A-3C (Without earth terminal)
SKT14A-3CG (With earth terminal)
94
25
25
24
SKT38A-3C (Without earth terminal)
SKT38A-3CG (With earth terminal)
94
25
25
24
17.5
17.5
M6
M6
2-ø4.5
32.5
32.5
80
65
80
65
2-ø4.5
M8
29.5
M8
29.5
67
67
60
60
Earth terminal
Earth terminal
75
75
SKT60A-3C (Without earth terminal)
SKT60A-3CG (With earth terminal)
30
24
115
30
SKT100A-3C (Without earth terminal)
SKT100A-3CG (With earth terminal)
135
24
23
35
29
M10
M8
2-ø5.5
115.5
89
2-ø6.5
43
34
90.5
69
29.5
80
95
79
M10
Earth terminal
Earth terminal
105
90
SKT38-S
10
M6
8 9
(26)
M8
10.3
15
14
SKT200-S
48
6
M16
33.1
M16
FUJI ED & C TIMES Vol. 6
11
8
34
15
71.5 max.
22
2
30
46
22
80 max.
22
2
30
46
22
80 max.
46.2
61.9 max.
15
23
M5
67
38
67
38
11
8
(13.4)
38.2
6.2
4
6
50
M10
20
Panel drilling
M10
M4 (depth 10)
M4 (depth 10)
(ø13)
64
50
4
(27.5)
2-M5
Mountig hole
2-ø6
ø14
4
62
14.6
12 7 12
(32)
12
18.8
SKT200-SD
64
50
6
2-M5
Mounting hole
2-ø6
17
62
71.5
36
2-ø4.5
ø5.3
(28)
4
33.3
43.4max
27.9
(8.4)
10.3
15
(11.8)
14
27.8
M10
9 10
(29)
M8
4
33.3
41.6max
26.1
4
(8.4)
M8
M8
SKT100-S
25
ø4.3
(27)
48
ø4.3
(27)
57
29
38.5
8 9
(26)
17.2
10
M6
19
38.1
50.4 max.
17
17.2
17
SKT60-S
53
26
22.8
53
26
11.6
• Connector
SKT14-S
38.5
M8
67
48
29.5
35
34
13
New
Products
AC voltage and current transducers
WT2AC series
Isolated AC transducers with a thin profile and
excellent cost performance
Features
FUJI WT2 AC voltage and current transducers convert AC
voltage/current into DC voltage/current, and also isolate input/
output circuits and power supplies.
• Select from an 85 to 264V AC, 24V DC, or 110V DC control
power supply
• Three isolated ports: input, output, and power supply
• Use either IEC 35mm rail mounting or screw mounting
• Screw terminals with cover ensure safe, sure connection.
Rail mounting
Screw mounting
Specifications and performance
Input-output
(mA) (mA) (mA) (V)
Output
• Performance
Accuracy: ±0.4% FS
Temperature characteristic: ±0.2%/10°C FS(Typical)
Response time: 0.5s max. (0 to 90%)
Insulation resistance: 100MΩ (500V DC megger)
Withstand voltage: 2000V AC 1min
10
5
20
5
6
3
12
3
2
1
4
1
• Input
Current input
Voltage output 0 to 10mV
0 to 100mV
0 to 1V
0 to 5V DC, 1 to 5V DC
0 to 10V DC
Current output 0 to 1mA DC
0 to 5mA DC
0 to 10mA DC
0 to 16mA DC
0 to 20mA DC
1 to 5mA DC
2 to 10mA DC
4 to 20mA DC
14
0.5
2.5
55
75
150
1
5
110
150
300
(A)
(A)
(V)
(V)
(V)
Input
• Output
Output signal
0
0
0
0
0
Input frequency
50Hz, 60Hz
Permissible external
resistance
10kΩ or more
100kΩ or more
200kΩ or more
1kΩ or more
2kΩ or more
15kΩ or less
3kΩ or less
1.5kΩ or less
900Ω or less
750Ω or less
3kΩ or less
1.5kΩ or less
750Ω or less
Output
Voltage input
Input signal
0 to 110V AC
0 to 150V AC
0 to 300V AC
0 to 1A AC
0 to 5A AC
(mA) (mA) (mA) (mA) (mA) (mV) (mV) (V)
(V)
(V)
20
16
10
10
5
10
8
0
0
5
1 100
10
5
2.5
0.5 50
5
0.5
5
2.5
0
0
0
0
0
0
0
0
1
0
0.5
0
2.5
1 (A)
5 (A)
55
110 (V)
0
75
150 (V)
0
150
300 (V)
0
Input
FUJI ED & C TIMES Vol. 6
AC voltage and current transducers WT2AC series
New Products
Dimensions, mm
• Rail mounting
• Screw mounting
127
80
104
Terminal screw
M3.5 x 8
97
25
127
35mm wide IEC rail
Panel
Mounting screw
M4 x 12
Panel drilling
One-unit mounted
n-unit mounted
26 x (n-1)
26
26
97
97
M4
Wiring diagram
Current input
Voltage input
U
u
V
VT
v
1 2
3 4
Output
K
CT
L
k
R
1 2
3 4
(–)
(+)
5 6
7 8
Control power
source
(+)
(–)
FUJI ED & C TIMES Vol. 6
15
New
Products
Arresters for low voltage circuit
CN233 series
Addition of 20kA models absorbing inductive
lightning surges from power supply
Features
• Coordinated operation of 2 types of varistors enables
extremely fast response to surges and a high level absorption.
• Built-in thermal fuses prevent problems such as short-circuit
due to deterioration of elements.
• Indicators for easy confirmation of device status
• Integrated terminal construction reduces space and wiring
requirements for easier handling of the arrester.
• Standard-feature terminal cover to protect against electrical
shock
CN233 series
Application
• Electronic devices, such as computers, measurement devices,
and communications devices
• Inverters and UPSs
• Electronic devices inside distribution boards (e.g., power
distribution boards and lighting distribution boards)
Specifications
CN23311
Single-phase/2-wire
110V
240 to 310V
420 to 520V
700V max.
1000V max.
5kA (2 times)
20kA (2 times)
Type
Rated voltage
Reference voltage
V1ma
Clamping voltage
Vp
Discharge current
(8/20µs)
Line
Ground
Line
Ground
Line
Ground
CN23312
Single-phase/2-wire
220V
420 to 520V
610 to 750V
1100V min.
1500V min.
CN23332
3-phase/3-wire
220V
420 to 520V
610 to 750V
1100V max.
1500V max.
Single-phase/3-wire
100V/200V
CN2334E
3-phase/3-wire
440V (Voltage to ground)
–
850 to 1100V
–
2500V max.
–
20kA (2 times)
Internal wiring
• CN23311, CN23312
1/L1
• CN23332
Z2
F
1/L1
Z1
E
1/L1
F:Thermal fuse
16
Z1
Z2
E
3/L2
Z2
E
3/L2
Z1
F
5/L3
L: Indicator
Z1
Z2
F
L
F
3/L2
Z2
Z2
F
L
L
• CN2334E
Z2
Z2
5/L3
Z1, Z2: Component for surge protective device
FUJI ED & C TIMES Vol. 6
Arresters for low voltage circuit CN233 series
New Products
Application example
• Single-phase/2-wire (110AC, 220V AC)
• Single-phase/3-wire (100/200V AC)
L1
N
L2
Fuse
(AFaC-30 or-60)
Fuse
(AFaC -30 or -60)
1/L1
1/L1 3/L2 5/L3
3/L2
CN23311, 12
CN23332
E
E
• 3-phase/3-wire (220V AC)
• 3-phase/3-wire (440V AC)
Inverter
Motor
Fuse
(AFaC-30 or -60)
Fuse
(AFaC-30 or -60)
1/L1 3/L2 5/L3
1/L1 3/L2 5/L3
CN2324L*
CN23332
E
1/L1 3/L2 5/L3
CN2334E
E
* Do not wire to the black-colored screw terminal.
Dimensions, mm
• CN233
50
16 16
12.5
Panel drilling
Terminal screw M5
M4
2
90
75
95
120
24
107 to 109
83
2
35mm wide rail
FUJI ED & C TIMES Vol. 6
25
Mounting plate
17
New
Products
AC power distribution monitoring
unit for one feeder, F-MPC04 series
Digital multimeters – all of the measurement functions for
AC power distribution monitoring in a single unit
Features
A wide variety of output functions to select from for
preventive maintenance
• Power alarm/current prealarm output provided
• Electric energy pulse signal provided
• Leakage current alarm, leakage current prealarm output
(with leakage current measuring function only)
Capable of measuring inrush current of equipment such
as welders
• High-speed sampling and calculation of voltage and current
UM03-ARA3
Compact design allows installation almost anywhere.
• Space-saving construction simplifies installation.
• Monitors individual equipment, sections, and the entire floor
Networking capability
• External interface uses RS-485 communications.
• Can be connected to the same electric power distribution
system as other F-MPC (04, 04P, 30, 60B series) products
System configuration
Distribution monitoring unit
UM03-ARA3
PC
RS-485
Types and functions
Converter
RS-232C
Function
Leakage current measuring
function
Not provided
Provided
Type
UM03-ARA3
UM03-ARA3G
Equipment
Specifications
• General
Applicable circuit
Control power supply
Inrush current
Control power consumption
Short-time overload Current input circuit
resistance
Voltage input circuit
Vibration
Shock
Withstand voltage / Insulation resistance
(500V DC megger)
Ambient temperature
Humidity
Atmosphere
Grounding
Allowable power interrupting time
18
3-phase 3-wire: 2-CT, single-phase 3-wire: 2-CT, single-phase 2-wire: 1-CT
100 to 200V AC ( 85 to 264V AC)
50/60Hz (45 to 66Hz)
15A, 3ms or less (at 110V AC, 50Hz)
30A, 3ms or less (at 220V AC, 50Hz)
Approx. 7VA (at 220V AC) Approx. 5VA (at 110V AC)
Max. 20 times setting value, 9 times for 0.5s
Max. 2 times setting value, 9 times for 0.5s
10 to 58Hz 0.075mm (one-way amplitude)
300m/s2, in each X, Y, and Z directions, 2 times
2kV /10MΩ Between power supply terminals connected together and other terminals connected together
2kV /10MΩ Between measurement input terminals connected together and other terminals connected together
2kV /10MΩ Between alarm output terminals connected together and other terminals connected together
500V /10MΩ Between watthour pulse output terminals connected together and other terminals connected together
Operating: -10 to +55˚C
Storage: -20 to +70˚C
20 to 90%RH (no condensation)
Free from corrosive gases and excessive of dusts
Grounding resistance of 100Ω or less
20ms (unit will continue operation)
FUJI ED & C TIMES Vol. 6
AC power distribution monitoring unit for one feeder and CTs
New Products
• Measurement
Item
Current, demand current
Max. demand current value
Demand value and max. demand value of
higher harmonic current
Demand active power
Max. demand active power value
Reactive power
Power factor
Active electric energy
Reactive electric energy
Voltage
Frequency
Leakage current (I/o /Iob)
Max. demand value
Effective measurement range
• With split toroidal CT (200A AC) *
0, 0.4 % of In (0.8A) to 300A
• With split toroidal CT (400A AC) *
0, 0.4% of In (1.6A) to 600A
• With small split toroidal CT (5A) *
0, 0.4% of In (0.2A) to 50A
0, to 1.5 times CT rating (for 5A)
• Demand time setting: 0, 1 to 15min
(by 1min stepped )
30min setting: Available
Converted into an input voltage
60 to 264 V AC
45 to 66Hz
0, 10 to 1000mA
4-digit
Accuracy
R- and T-phase: ±1.5% FS
S-phase: ±2.5% FS
± 2.5% FS
4-digit
±1.5% FS
4-digit
3-digit
5-digit
5-digit
4-digit
±3% FS
±5% FS Converted into a phase angle of 90˚
Equivalent to JIS standard class
±5%
Vu-v and Vw-u: ±1.5% FS, Vv-w: ±2.5% FS
3-digit
4-digit
±0.5% FS
±2.5%
Display
4-digit
Note: New model CTs, see page 20.
• Output
Item
Watt-hour pulse output
Alarm output
Current prealarm (OCA), power alarm
Leakage current prealarm (OCGA)
Leakage current alarm (OCGA)
UM03-ARA3
Provided
Provided
Not provided
Front panel
POWER
UM03-ARA3G
Provided
Provided
Provided
Specification
Transistor open collector output 35V DC 100mA
Replay output 250V AC 1A
• Terminal layout
OCA
1
11
OCGA
2
12
Measurement mode display LEDs
DEMAND HIST
SET
TEST
Measurement value, or set value display
A
cosø
V
Hz
R(U-V)
S(V-W)
T(W-U)
kWh
kvarh
kW
kvar
ALARM
Watthour pulse output
terminals
Alarm output terminals
OCG
3
13
DXA
COM
4
14
DXB
U
5
15
SG
V
6
16
Ir-k
W
7
17 COM-I
Display item, or unit LEDs
X10
RS-485 communication
terminals
X100
X1000
Measurement voltage
input terminals
Selection switches
SELECT
Watt-hour
pulse
SET
Control power input
terminals
8
100-240V AC
9
10
18
Measurement current
input terminals
It-k
19
20
ZCT
Leakage current
input terminals
FG
Note: Alarm output terminal 2 3 and ZCT input terminal 19 20 of the
UM03-ARA3 (without leakage current measuring function) are
NC terminals. Do not connect anything to these terminals.
Dimensions, mm
Panel cutting
POWER
SET
V
Hz
kW
kvar
ALARM
kWh
kvarh
X10
X100
X1000
120 min.
R(U-V)
S(V-W)
T(W-U)
45 +0.6
0
TEST
92 +0.8
0
A
cosø
96
107
DEMAND HIST
48
12
Mass: Approx. 400g
FUJI ED & C TIMES Vol. 6
102
Bracket for panel mounting
60 min.
19
New Products AC power distribution monitoring unit for one feeder and CTs
New split toroidal type current transformers/CC2D
Features
Designed for even easier handling. Line-up includes types
designed specially for FUJI multiple function protectors and
controllers (F-MPC), and types for use with other
instrumentation.
• Improved design enables easier mounting.
• Large K L display allows easier identification of primary
conductor direction.
• Hook attached makes it easier to secure the primary
conductor with a retaining band.
• Built-in clamping diode (on all types except the CC2D81)
CT secondary wiring will not burn out even with the contact
open.
CC2D
Types and ratings
Type
Rated
primary
current (A)
Mass
(g)
Rated
secondary
current
Rated
frequency
(Hz)
Rated burden
Withstand voltage
Connection
0.2693mVA
Load resistance:
5Ω
26.93mVA
Load resistance:
5Ω
44.4mVA
Load resistance:
10Ω or less
88.9mVA
Load resistance:
5Ω or less
0.5VA
Load resistance:
0.5Ω or less
1000V AC/1min
Between sensor core
and output
1000V AC/1min
Between sensor core
and output
2000V AC/1min
Between sensor core
and output
2000V AC/1min
Between sensor core
and output
2000V AC/1min or more
Between sensor core
and output
Heat-resistant IV cable
AWG22 x1000mm supplied
45
Heat-resistant IV cable
AWG22 x1000mm supplied
45
Heat-resistant IV cable
AWG18 x1000mm supplied
200
Heat-resistant IV cable
AWG18 x1000mm supplied
300
Heat-resistant IV cable
AWG18 x1000mm supplied
300
CC2D81-0057
5
7.34mA
50/60
CC2D81-0506
50
73.4mA
50/60
CC2D65-2008
200
66.7mA
50/60
CC2D54-4009
400
133.33mA
50/60
CC2D74-1001
CC2D74-2001
CC2D74-4001
100
200
400
1A
1A
1A
50/60
Performance
Application
Type
Ratio error
Phase difference
Insulation resistance
Output protection
Operating
temperature
and humidity
For F-MPC
CC2D81-0057
±1% In
±1.5%/0.2 In
150' ±150' /In
180' ±180' /0.2 In
150' ±150' /In
180' ±180' /0.2 In
±60' /In
±90' /0.2 In
±60' /In
±90' /0.2 In
90' ±90' /In
120' ±120' /0.2 In
60' ±60' /In
90' ±90' /0.2 In
±80' /In ±100' /0.2 In
100MΩ
(500V DC megger)
Not provided
–20 to +50°C
80%RH or less
No condensation
100MΩ
(500V DC megger)
Provided
Built-in clamping diode
CC2D81-0506
CC2D65-2008
CC2D54-4009
General
purpose
CC2D74-1001
CC2D74-2001
CC2D74-4001
20
±1% In
±1.5%/0.2 In
FUJI ED & C TIMES Vol. 6
AC power distribution monitoring unit for one feeder and CTs
New Products
Dimensions, mm
• CC2D81
26
• CC2D65
1
23
1
1.5
13.5
45
1
4
34
4
22
ø10
K
27
39
ø2
4
L
K
L
64
Clamp
36
39
k (White)
1000
l (Black)
Clamp
k (White)
Output lead
AWG22: 1000mm
Hook
l (Black)
Output lead
AWG18: 1000mm
• CC2D54, CC2D74
1.5
57
1
4
38
4
ø3
6
22
L
49
Clamp
45
80
K
Hook
k (White)
l (Black)
Output lead
AWG18: 1000mm
FUJI ED & C TIMES Vol. 6
21
Modified Products
Miniature control relays / HH52, HH54 series
Change in external terminals
• Standard
Plug-in mounting: HH54P, HH54PW, HH52P-R
Flange mounting: HH54S, HH54SW, HH52S-R
Conventional
New
Projection
• High capacity
Plug-in mounting: HH54PU
Flange mounting: HH54SU
Terminals
• With extra pick-up coil
Plug-in mounting: HH54-2P
Flange mounting: HH54-2S
■ Time of modification: April 2004
Miniature control relays / Sockets for rail mounting
Changes in company logo of sockets
• Screw terminal M3
TP58X1: For HH52P
TP514X1: For HH54P
Conventional
Upper
Side
New
Bottom
Upper
Bottom
New logo
TP514X1
Logo
Side
Type number
Name plate
Name plate
■ Time of modification: May 2004
22
FUJI ED & C TIMES Vol. 6
Modified Products
Display lights and multi display lights
Change in shape of mounting kit APX111
Conventional
New
3.8mm
2.8mm
■ Time of modification: February 2004
Manual motor starters / BM3 series
Change in nameplates on right side
Conventional
• 32AF types: BM3RSB
BM3RHB
BM3RHBK
New
Added Tap Conductor
Protection
• 63AF types: BM3VSB
BM3VHB
BM3VHBK
■ Time of modification: April 2004
FUJI ED & C TIMES Vol. 6
Added combined contactor type number
conforming to UL508 Type F
23
Discontinued Products
The production of the following products has or will soon be discontinued.
Please use substituting models.
AS-Interface Waterproof connector-type slave module FM6D, FM6B
• Slaves
4-input (NPN)
4-output (NPN)
2-input/2-output (NPN)
• Slave bases
Pressure welding connection
Screw terminal connection
Discontinued
Substitute
FM6D-40XXN
FM6D-04TNX
FM6D-22TNN
FM6D1-40XXN
FM6D1-04TNX
FM6D1-22TNN
FM6B1-04FK
FM6B1-04FE
None
None
FM6B-04FK
FM6B-04FE
FM6B-04PG
FM6B-04PE
■ Time of discontinuation: March 2004
Further
Information
Contact FUJI for details of
substituting models.
AS-Interface Power supply FP1B-JNW213
Discontinued
• For communications/external
aux. power supply
Substitute
FP1B-JNW213
None
■ Time of discontinuation: February 2004
AS-Interface DeviceNet/AS-i gateway FC2L-DL
Discontinued
• Conversion capsule
FC2L-DL
(Version2.0)
Substitute
FC2LA-DL
(Version2.1)
Hardware and software are compatible.
Contact FUJI for details of
Further
Information substituting models.
■ Time of discontinuation: March 2004
Safety Considerations
• For safe operation, before using the product read the instruction manual or user manual that comes with the product carefully or consult the
Fuji sales representative from which you purchased the product.
• Products introduced in this catalog have not been designed or manufactured for such applications in a system or equipment that will affect
human bodies or lives.
• Customers, who want to use the products introduced in this catalog for special systems or devices such as for atomic-energy control,
aerospace use, medical use, passenger vehicle, and traffic control, are requested to consult the Fuji sales division.
• Customers are requested to prepare safety measures when they apply the products introduced in this catalog to such systems or facilities
that will affect human lives or cause severe damage to property if the products become faulty.
• For safe operation, wiring should be conducted only by qualified engineers who have sufficient technical knowledge about electrical work or
wiring.
Gate City Ohsaki, East Tower
11-2, Osaki 1-chome, Shinagawa-ku, Tokyo, 141-0032, Japan
Phone: +81-3-5435-7135~8
Fax:
+81-3-5435-7456~9
URL http://www.fujielectric.co.jp/fcs/eng
Printed on 100% recycled paper using soy-based ink
Information in this catalog is subject to change without notice.
Printed in Japan 2004-3 L25 FIS