RECESSED LIGHTING FLUORESCENT 4” 452 454 456 458 460 A2000V A2010V A2000VL A2010VL A2000VLS 462 464 466 468 470 A2010VLS A2000VS A2010VS A2400S A2450S 472 474 476 478 480 B2675 F2450VT F2575R F2575RU FB2675 486-488 490-492 494-496 498-500 502-504 FR6HO FR6HOLA FR6HOLB FR6HOW90 FR6HOW120 506-512 514 516-518 520-522 524-526 FR6VO FR6VOG FR6VOLA FR6VOLB FR6VOW90 528-530 532-534 FR6VOW90D FR6VOW120 538 540 542 544 546 FR7C FR7O FR7OLA FR7OLB FR7T 550 552 554 556 558 FR8C FR8O FR8OLA FR8OLB FR8T 482 FC2675 6” 7” 8” 10 www.contrastlighting.com Compact Fluorescent Energy Efficient Lighting 4” 450 www.contrastlighting.com fluorescent FR8C-11 See page 550 for more details 451 FLUO 4” A2000V Downlight A2000V-02 Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000V) Cobalt Blue (A2010V). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 211/16” 68mm 111/16” 43mm Hole Cut : 41/4” 21/2” 63mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2000V-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code.Ex.: A2000V-01MG 452 www.contrastlighting.com A2000V Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF2000D18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: NWF2000D182 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 120˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 30 60° 50 70 45° 90 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.4 1.3 0.9 0.6 0.4 0.3 0.3 0.2 DIA 5.7’ 7.6’ 9.5’ 11.3’ 13.2’ 15.1’ 17.0’ 18.9’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 57.7% Spacing Criteria 1.7 Certificate S0604261 80 50 30 67 67 47 42 35 29 28 22 23 17 19 14 50 50 30 60 60 42 38 31 27 25 20 20 16 17 13 30 50 30 56 56 39 36 29 25 23 19 19 15 16 12 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 55 75 45° 100 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.6 1.4 0.9 0.6 0.5 0.4 0.3 0.2 DIA 2.7’ 3.7’ 4.6’ 5.5’ 6.4’ 7.3’ 8.2’ 9.2 Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 45.3% Spacing Criteria 1.6 Certificate S0512014 80 50 30 53 53 38 34 29 24 23 18 19 15 16 12 50 50 30 47 47 34 31 26 22 21 17 17 14 14 11 30 50 30 44 44 32 29 24 21 19 16 16 13 14 11 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 50 60° 75 100 45° 125 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.6 2.0 1.3 0.9 0.7 0.5 0.4 0.3 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 40.2% Spacing Criteria 1.4 Certificate S0512011 80 50 30 47 47 34 31 26 23 21 17 17 14 15 11 50 50 30 43 43 31 29 24 21 19 16 16 13 14 11 30 50 30 40 40 29 27 23 20 18 16 15 13 13 10 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 40 75° 80 60° 120 160 45° 200 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.5 3.1 2.0 1.4 1.0 0.8 0.6 0.5 DIA 2.1’ 2.9’ 3.6’ 4.3’ 5.0’ 5.7’ 6.4’ 7.1’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 46.7% Spacing Criteria 1.5 Certificate S0512052 80 50 30 54 54 39 36 30 26 24 19 20 15 16 13 50 50 30 49 49 35 33 27 24 22 18 18 15 15 12 30 50 30 46 46 33 31 25 22 21 17 17 14 14 12 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 453 FLUO 4” A2010V Downlight A2010V-02 Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000V) Cobalt Blue (A2010V). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 211/16” 68mm 111/16” 43mm Hole Cut : 41/4” 21/2” 63mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 18W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2010V-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2010V-14MG 454 www.contrastlighting.com A2010V Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2000D26 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: F2000D262 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 120˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 0 75° 10 60° 20 30 45° 40 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.0 0.6 0.4 0.3 0.2 0.1 0.1 0.1 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 12.1% Spacing Criteria 1.8 Certificate S0604262 80 50 30 14 14 11 11 09 08 07 06 06 05 05 04 50 50 30 13 13 11 10 08 08 07 06 06 05 05 04 30 50 30 13 13 10 10 08 07 07 06 06 05 05 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 15 60° 25 30 45° 40 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.1 0.6 0.4 0.3 0.2 0.2 0.1 0.1 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 7.7% Spacing Criteria 1.5 Certificate S0512051 80 50 30 09 09 08 07 06 06 05 05 05 04 04 03 50 50 30 09 09 07 07 06 06 05 05 04 04 04 03 30 50 30 08 08 07 07 06 06 05 05 04 04 04 03 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 25 60° 40 55 45° 70 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.9 1.0 0.7 0.5 0.3 0.3 0.1 0.1 DIA 0.8’ 1.1’ 1.4’ 1.7’ 2.0’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 7.9% Spacing Criteria 1.2 Certificate S0512013 80 50 30 09 09 08 08 07 06 06 05 05 04 04 04 50 50 30 09 09 08 07 07 06 06 05 05 04 04 04 30 50 30 08 08 07 07 06 06 05 05 05 04 04 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 60 80 45° 100 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.7 1.5 1.0 0.7 0.5 0.4 0.3 0.2 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 9.4% Spacing Criteria 1.4 Certificate S0512054 80 50 30 11 11 09 09 08 07 07 06 06 05 05 04 50 50 30 10 10 09 09 07 07 06 06 05 05 05 04 30 50 30 10 10 09 08 07 07 06 06 05 05 05 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 455 FLUO 4” A2000VL Downlight A2000VL-04BR Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VL) Cobalt Blue (A2010VL). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 215/16” 74mm 115/16” 49mm Hole Cut : 41/4” 23/16” 55mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2000VL-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2000VL-11MG 456 www.contrastlighting.com A2000VL Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF2000D18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: NWF2000D182 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 120˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 30 60° 50 70 45° 90 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.4 1.3 0.9 0.6 0.4 0.3 0.3 0.2 DIA 5.7’ 7.6’ 9.5’ 11.3’ 13.2’ 15.1’ 17.0’ 18.9’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 57.7% Spacing Criteria 1.7 Certificate S0604261 80 50 30 67 67 47 42 35 29 28 22 23 17 19 14 50 50 30 60 60 42 38 31 27 25 20 20 16 17 13 30 50 30 56 56 39 36 29 25 23 19 19 15 16 12 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 55 75 45° 100 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.6 1.4 0.9 0.6 0.5 0.4 0.3 0.2 DIA 2.7’ 3.7’ 4.6’ 5.5’ 6.4’ 7.3’ 8.2’ 9.2 Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 45.3% Spacing Criteria 1.6 Certificate S0512014 80 50 30 53 53 38 34 29 24 23 18 19 15 16 12 50 50 30 47 47 34 31 26 22 21 17 17 14 14 11 30 50 30 44 44 32 29 24 21 19 16 16 13 14 11 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 50 60° 75 100 45° 125 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.6 2.0 1.3 0.9 0.7 0.5 0.4 0.3 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 40.2% Spacing Criteria 1.4 Certificate S0512011 80 50 30 47 47 34 31 26 23 21 17 17 14 15 11 50 50 30 43 43 31 29 24 21 19 16 16 13 14 11 30 50 30 40 40 29 27 23 20 18 16 15 13 13 10 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 40 75° 80 60° 120 160 45° 200 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.5 3.1 2.0 1.4 1.0 0.8 0.6 0.5 DIA 2.1’ 2.9’ 3.6’ 4.3’ 5.0’ 5.7’ 6.4’ 7.1’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 46.7% Spacing Criteria 1.5 Certificate S0512052 80 50 30 54 54 39 36 30 26 24 19 20 15 16 13 50 50 30 49 49 35 33 27 24 22 18 18 15 15 12 30 50 30 46 46 33 31 25 22 21 17 17 14 14 12 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 457 FLUO 4” A2010VL Downlight A2010VL-08 Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VL) Cobalt Blue (A2010VL). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 215/16” 74mm 115/16” 49mm Hole Cut : 41/4” 23/16” 55mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2010VL-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2010VL-11MG 458 www.contrastlighting.com A2010VL Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: ISF2000D18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: ISF2000D182 • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 Mounting Bars • Take up to 7/8” thick ceilings • For NW and IC housings. • Adjustable and lockable from 10” to 24”. Trims • Lockable integral T-Bar tabs. May be hung Plated or painted steel from trusses or suspended ceilings. Efficient CFL Housings Housing Features Socket & Lamp Bases • Galvanized steel High temperature-rated • Below ceiling accessible 120˚C instead of 90˚C • Keyhole on socket assembly for easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 00 75° 10 60° 20 30 45° 40 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.0 0.6 0.4 0.3 0.2 0.1 0.1 0.1 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 12.1% Spacing Criteria 1.8 Certificate S0604262 80 50 30 14 14 11 11 09 08 07 06 06 05 05 04 50 50 30 13 13 11 10 08 08 07 06 06 05 05 04 30 50 30 13 13 10 10 08 07 07 06 06 05 05 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 15 60° 25 30 45° 40 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.1 0.6 0.4 0.3 0.2 0.2 0.1 0.1 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 7.7% Spacing Criteria 1.5 Certificate S0512051 80 50 30 09 09 08 07 06 06 05 05 05 04 04 03 50 50 30 09 09 07 07 06 06 05 05 04 04 04 03 30 50 30 08 08 07 07 06 06 05 05 04 04 04 03 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 25 60° 40 55 45° 70 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.9 1.0 0.7 0.5 0.3 0.3 0.1 0.1 DIA 0.8’ 1.1’ 1.4’ 1.7’ 2.2’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 7.9% Spacing Criteria 1.2 Certificate S0512013 80 50 30 09 09 08 08 07 06 06 05 05 04 04 04 50 50 30 09 09 08 07 07 06 06 05 05 04 04 04 30 50 30 08 08 07 07 06 06 05 05 05 04 04 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 60 80 45° 100 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.7 1.5 1.0 0.7 0.5 0.4 0.3 0.2 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 9.4% Spacing Criteria 1.4 Certificate S0512054 80 50 30 11 11 09 09 08 07 07 06 06 05 05 04 50 50 30 10 10 09 09 07 07 06 06 05 05 05 04 30 50 30 10 10 09 08 07 07 06 06 05 05 05 04 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 459 FLUO 4” A2000VLS Shower A2000VLS-04BR Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VLS) Cobalt Blue (A2010VLS). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 215/16” 74mm 115/16” 49mm Hole Cut : 41/4” 23/16” 55mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2000VLS-05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2000VLS-05MG 460 www.contrastlighting.com A2000VLS Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: ISF2000D18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: ISF2000D182 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 130˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 25 60° 40 55 45° 70 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.0 1.1 0.7 0.5 0.4 0.3 0.2 0.2 LUMINAIRE DIA 11.4’ 15.2’ 19.1’ 22.9’ 26.7’ 30.5’ 34.3’ 38.1’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° Lamp Type Initial Lumens COEFFICIENT OF UTILIZATION - % Input Watts 13W Quad, 2pin 780 120V 16W Operating AMPS 0.13A Luminaire Efficiency 51.0% Spacing Criteria 1.5 Certificate S0604263 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 59 59 41 37 31 26 24 19 20 15 16 12 50 50 30 53 53 36 33 27 23 21 17 18 14 15 11 30 50 30 49 49 33 28 25 19 20 14 16 11 14 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 25 60° 40 55 45° 75 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.9 1.1 0.7 0.5 0.4 0.3 0.2 0.2 DIA 3.7’ 5.0’ 6.2’ 7.5’ 8.7’ 10.0’ 11.2’ 12.4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 39.6% Spacing Criteria 1.4 Certificate S0512015 80 50 30 46 46 32 29 24 20 19 15 16 12 13 10 50 50 30 41 41 29 26 22 19 17 14 14 11 12 09 30 50 30 38 38 26 24 20 17 16 13 13 11 11 09 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 60 80 45° 100 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.9 1.6 1.0 0.7 0.5 0.4 0.3 0.3 DIA 2.7’ 3.7’ 4.6’ 5.5’ 6.4’ 7.3’ 8.2’ 9.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 39.7% Spacing Criteria 1.4 Certificate S0512012 80 50 30 46 46 33 30 25 21 20 16 16 12 13 10 50 50 30 41 41 29 27 22 19 18 15 15 12 12 10 30 50 30 39 39 27 25 21 18 17 14 14 11 12 09 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 50 60° 80 100 45° 130 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.6 2.0 1.3 0.9 0.7 0.5 0.4 0.3 DIA 3.7’ 5.0’ 6.2’ 7.5’ 8.7’ 10.0’ 11.2’ 12.4’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 34.9% Spacing Criteria 1.4 Certificate S0512053 80 50 30 41 41 29 26 22 18 17 14 14 11 12 09 50 50 30 36 36 26 23 19 17 15 13 13 10 11 08 30 50 30 34 34 24 22 18 16 14 12 12 10 10 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 461 FLUO 4” A2010VLS Shower A2010VLS-12BR Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VLS) Cobalt Blue (A2010VLS). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 215/16” 74mm 115/16” 49mm Hole Cut : 41/4” 23/16” 55mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2010VLS-06 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2010VLS-11MG 462 www.contrastlighting.com A2010VLS Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2000D26 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: F2000D262 • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 Mounting Bars • Take up to 7/8” thick ceilings • For NW and IC housings. • Adjustable and lockable from 10” to 24”. Trims • Lockable integral T-Bar tabs. May be hung Plated or painted steel from trusses or suspended ceilings. Efficient CFL Housings Housing Features Socket & Lamp Bases • Galvanized steel High temperature-rated • Below ceiling accessible 120˚C instead of 90˚C • Keyhole on socket assembly for easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 LUMINAIRE DIA 11.4’ 17.1’ 22.8’ 28.5’ 34.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower Lamp Type Initial Lumens Input Watts Operating AMPS NOTES 13W Quad, 2pin 780 120V 16W 0.13A 13W Elect. DTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 LUMINAIRE DIA 9.5’ 14.2’ 19.0’ 23.8’ 28.5’ Lamp Type Initial Lumens Input Watts Operating AMPS NOTES 13W Quad, 4pin 900 120V 277V 347V 18W 18W 18W 0.15A 0.07A 0.06A Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Elect. TTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 NOTES LUMINAIRE DIA 9.5’ 14.2’ 19.0’ 23.8’ 28.5’ Lamp Type Initial Lumens Input Watts Operating AMPS 18W Triple Tube, 4pin 1200 120V 277V 347V 19W 19W 21W 0.16A 0.07A 0.06A Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Elect. TTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.2 0.1 0.1 0.1 0.1 NOTES LUMINAIRE DIA 8’ 12’ 16’ 20’ 24’ Lamp Type Initial Lumens Input Watts Operating AMPS 26W Triple Tube, 4pin 1800 120V 277V 347V 28W 28W 31W 0.25A 0.11A 0.09A Beam Edge defined as 50% of Maximum Nadir Candlepower 463 FLUO 4” A2000VS Shower A2000VS-04BR Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VS) Cobalt Blue (A2010VS). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 211/16” 68mm 111/16” 43mm Hole Cut : 41/4” 21/2” 63mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2000VS-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: R3470-14MG 464 www.contrastlighting.com A2000VS Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2000D26 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: F2000D262 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 120˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000U13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000U13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 25 60° 40 55 45° 70 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.0 1.1 0.7 0.5 0.4 0.3 0.2 0.2 DIA 11.4’ 15.2’ 19.1’ 22.9’ 26.7’ 30.5’ 34.3’ 38.1’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 51.0% Spacing Criteria 1.5 Certificate S0604263 80 50 30 59 59 41 37 31 26 24 19 20 15 16 12 50 50 30 53 53 36 33 27 23 21 17 18 14 15 11 30 50 30 49 49 33 28 25 19 20 14 16 11 14 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 25 60° 40 55 45° 75 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.9 1.1 0.7 0.5 0.4 0.3 0.2 0.2 DIA 3.7’ 5.0’ 6.2’ 7.5’ 8.7’ 10.0’ 11.2’ 12.4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 39.6% Spacing Criteria 1.4 Certificate S0512015 80 50 30 46 46 32 29 24 20 19 15 16 12 13 10 50 50 30 41 41 29 26 22 19 17 14 14 11 12 09 30 50 30 38 38 26 24 20 17 16 13 13 11 11 09 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 40 60° 60 80 45° 100 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.9 1.6 1.0 0.7 0.5 0.4 0.3 0.3 DIA 2.7’ 3.7’ 4.6’ 5.5’ 6.4’ 7.3’ 8.2’ 9.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 39.7% Spacing Criteria 1.4 Certificate S0512012 80 50 30 46 46 33 30 25 21 20 16 16 12 13 10 50 50 30 41 41 29 27 22 19 18 15 15 12 12 10 30 50 30 39 39 27 25 21 18 17 14 14 11 12 09 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 50 60° 80 100 45° 130 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.6 2.0 1.3 0.9 0.7 0.5 0.4 0.3 DIA 3.7’ 5.0’ 6.2’ 7.5’ 8.7’ 10.0’ 11.2’ 12.4’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 34.9% Spacing Criteria 1.4 Certificate S0512053 80 50 30 41 41 29 26 22 18 17 14 14 11 12 09 50 50 30 36 36 26 23 19 17 15 13 13 10 11 08 30 50 30 34 34 24 22 18 16 14 12 12 10 10 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 465 FLUO 4” A2010VS Shower A2010VS-12BR Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Glass The glass is available in 2 colors. Natural (A2000VS) Cobalt Blue (A2010VS). Housings Specifications New Construction (NW) Code NWF2000U13 NWF2000U18 NWF2000U26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 6” 6” 6” 211/16” 68mm 111/16” 43mm Hole Cut : 41/4” 21/2” 63mm Remodel Code F2000 F2000U13 F2000U18 F2000U26 Lamp 1 X 13W 1 X 13W 1 X 18W 1 X 26W DTT DTT TTT TTT Base GX23-2 G24q-1 GX24q-2 GX24q-3 (2 (4 (4 (4 pin) pin) pin) pin) Volts 120V 120-277V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic Electronic L W 13” 139/16” 139/16” 139/16” X X X X Hole Cut : H 51/8” 51/8” 51/8” 51/8” X X X X 4” 102mm 4” 61/16” 61/16” 61/16” ø 53/16” 132mm 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000 1 ISF2000U13 1 ISF2000U18 Lamp 1 X 13W 1 X 13W 1 X 26W DTT DTT TTT Base GX23-2 (2 pin) G24q-1 (4 pin) GX24q-2 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/16” 193/8” 193/8” X X X H 81/8” 10” 10” X X X ø 21/8” 54mm 71/2” 61/16” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2010VS-04 For exterior use Wet and Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2010VS-01MG 466 www.contrastlighting.com A2010VS Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF2000D18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: NWF2000D182 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Trims from trusses or suspended ceilings. Plated or painted steel Housing Features Efficient CFL Housings • Galvanized steel Socket & Lamp Bases • Below ceiling accessible High temperature-rated • Keyhole on socket assembly for 120˚C instead of 90˚C easier installation • See specs in Housing Section Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000U13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000U13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Magn. DTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 LUMINAIRE DIA 11.4’ 17.1’ 22.8’ 28.5’ 34.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower Lamp Type Initial Lumens Input Watts Operating AMPS NOTES 13W Quad, 2pin 780 120V 16W 0.13A 13W Elect. DTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 LUMINAIRE DIA 9.5’ 14.2’ 19.0’ 23.8’ 28.5’ Lamp Type Initial Lumens Input Watts Operating AMPS NOTES 13W Quad, 4pin 900 120V 277V 347V 18W 18W 18W 0.15A 0.07A 0.06A Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Elect. TTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 NOTES LUMINAIRE DIA 9.5’ 14.2’ 19.0’ 23.8’ 28.5’ Lamp Type Initial Lumens Input Watts Operating AMPS 18W Triple Tube, 4pin 1200 120V 277V 347V 19W 19W 21W 0.16A 0.07A 0.06A Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Elect. TTT CONE OF LIGHT Distance 04’ 06’ 08’ 10’ 12’ FC 0.1 0.1 0.1 0.0 0.0 NOTES LUMINAIRE DIA 8’ 12’ 16’ 20’ 24’ Lamp Type Initial Lumens Input Watts Operating AMPS 26W Triple Tube, 4pin 1800 120V 277V 347V 28W 28W 31W 0.25A 0.11A 0.09A Beam Edge defined as 50% of Maximum Nadir Candlepower 467 FLUO 4” A2400S Shower A2400S-01 Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Lenses Standard: UV frosted lens (110mm). Ex.: A2400S. Also Available: Frosted convex: A2401S Clear convex: A2402S Clear: A2403S Frosted with clear center: A2404S See page 576 for more details. 2 STANDARD 3 1 4 Housings Specifications 7/16” 11mm New Construction (NW) Code NW2000LF NWF2000LU18 NWF2000LU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 13/8” 35mm 71/4” 71/4” 71/4” Hole Cut : 41/4” Remodel Code F2000L F2000LU18 F2000LU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/4” 1311/16” 1311/16” X X X H 51/8” 51/8” 51/8” X X X 71/4” 71/4” 71/4” ø 53/16” 132mm Hole Cut : 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000L 1 ISF2000LU18 Lamp 1 X 13W 1 X 18W DTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) Volts 120V 120-277V Ballast L HPF Magn. 153/16” Electronic 193/8” W H X 81/8” X 71/2” X 10” X ø 41/16” 103mm 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2400S-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2400S-01MG 468 www.contrastlighting.com A2400S Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF2000LD18 • 277V: For dimming capability, change «U» • Keyhole on socket assembly for to «D» and add «2» at the end of the housing easier installation code of 18W to 42W. Ex: NWF2000LD182 • See specs in Housing Section Emergency Ballast Available for New Construction housing (NW) with Electronic Ballast (120-277V). Add «EM» to housing code. Ex: NWF2000LU26EM Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Trims Plated or painted steel Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000LU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000LU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 30 60° 45 60 45° 75 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 2.0 1.1 0.7 0.5 0.4 0.3 0.2 0.2 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 26.9% Spacing Criteria 1.4 Certificate S0608073R1 80 50 30 32 32 25 23 19 17 16 13 13 11 11 09 50 50 30 30 30 23 22 18 17 15 13 12 10 11 09 30 50 30 27 27 22 21 17 16 14 12 12 10 10 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 50 60° 75 100 45° 125 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.5 2.0 1.3 0.9 0.6 0.5 0.4 0.3 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 29.5% Spacing Criteria 1.4 Certificate S0512081 80 50 30 35 35 27 25 21 19 17 15 14 12 12 10 50 50 30 33 33 26 24 20 18 16 14 14 12 12 10 30 50 30 31 31 25 24 20 18 16 14 13 11 11 10 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 35 75° 75 60° 115 150 45° 190 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.1 2.9 1.8 1.3 0.9 0.7 0.6 0.5 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 30.1% Spacing Criteria 1.4 Certificate S0512072 80 50 30 36 36 28 26 22 19 17 15 14 12 12 10 50 50 30 33 33 26 25 20 18 17 14 14 12 12 10 30 50 30 32 32 25 24 20 18 16 14 13 11 11 09 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 469 FLUO 4” A2450S Shower A2450S-08 Vertical Wet location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Lenses Standard: UV frosted lens (110mm). Ex.: A2450S. Also Available: Frosted convex: A2451S Clear convex: A2452S Clear: A2453S Frosted with clear center: A2454S See page 576 for more details. 2 STANDARD 3 1 4 13/16” 30mm Housings Specifications 1/8” 3mm New Construction (NW) Code NW2000LF NWF2000LU18 NWF2000LU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 71/4” 71/4” 71/4” Hole Cut : 41/4” Remodel Code F2000L F2000LU18 F2000LU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120V 120-277V 120-277V Ballast HPF Magn. Electronic Electronic L W 153/4” 1311/16” 1311/16” X X X H 51/8” 51/8” 51/8” X X X ø 3” 76mm ø 47/8” 124mm 71/4” 71/4” 71/4” Hole Cut : 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000L 1 ISF2000LU18 Lamp 1 X 13W 1 X 18W DTT TTT Base GX23-2 (2 pin) GX24q-2 (4 pin) Volts 120V 120-277V Ballast L HPF Magn. 153/16” Electronic 193/8” W X X H 81/8” 10” X X 71/2” 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: A2450S-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: A2450S-11MG 470 www.contrastlighting.com A2450S Vertical Technical Specifications 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2000LD18 • 277V: For dimming capability, change «U» • Keyhole on socket assembly for to «D» and add «2» at the end of the housing easier installation code of 18W to 42W. Ex: F2000LD182 • See specs in Housing Section Emergency Ballast Available for New Construction housing (NW) with Electronic Ballast(120-277V). Add «EM» to housing code. Ex: NWF2000LU26EM Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Trims Plated or painted steel Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000LU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000LU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Photometric Data 13W Magn. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 13 75° 25 60° 38 50 45° 63 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 1.7 1.0 0.6 0.4 0.3 0.2 0.2 0.2 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 23.8% Spacing Criteria 1.4 Certificate S0608071R1 80 50 30 28 28 22 20 17 15 14 11 11 09 10 08 50 50 30 27 27 20 19 16 14 13 11 11 09 09 07 30 50 30 24 24 19 18 15 14 12 11 10 09 09 07 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 20 75° 45 60° 65 90 45° 110 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.0 1.7 1.1 0.8 0.6 0.4 0.3 0.3 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 26% Spacing Criteria 1.4 Certificate S0512074 80 50 30 31 31 24 22 19 16 15 13 13 10 11 09 50 50 30 29 29 23 21 18 16 14 12 12 10 10 08 30 50 30 28 28 22 21 17 16 14 12 12 10 10 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 30 75° 65 60° 100 130 45° 160 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 4.4 2.5 1.6 1.1 0.8 0.6 0.5 0.4 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 26.7% Spacing Criteria 1.4 Certificate S0512061 80 50 30 32 32 24 23 19 17 15 13 13 10 11 09 50 50 30 30 30 23 22 18 16 15 13 12 10 10 08 30 50 30 28 28 22 21 17 16 14 12 12 10 10 08 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 471 FLUO 4” B2675 Downlight B2675-08 Vertical modèle Damp location Compact fluorescent: 1 X CFQ-13W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Champagne finish: Add «CH» after the housing code. Ex.: F2675RCH Housings Specifications 5/8” 16mm New Construction (NW) Code NW2675F Lamp 1 X 13W DTT Base GX23-2 (2 pin) Volts 120V Ballast L HPF Magn. 1411/16” W X 17/8” 48mm H 10” X 6” X 6” X 71/2” Hole Cut : 45/8” Remodel Code F2675R Lamp 1 X 13W DTT Base GX23-2 (2 pin) Volts 120V Ballast L HPF Magn. 143/4” W X H 59/16” ø 6” 152mm Hole Cut : 45/8” Insulated Ceiling (IC)1 Code 1 ISF2675R Lamp 1 X 13W DTT Base GX23-2 (2 pin) Volts 120V Ballast L HPF Magn. 153/16” W X H 81/8 ø 37/8” 98mm Hole Cut : 45/8” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: B2675-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: B2675-11MG 472 www.contrastlighting.com B2675 Vertical Technical Specifications Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Trims Plated or painted steel Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent champagne finish. Add «CH» to housing code. Ex: F2575RCH Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2575RW • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2575RP 4” FLUO 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Photometric Data 13W Magn. DTT - Clear Reflector CANDLEPOWER DISTRIBUTION Candelas 90° 10 75° 40 60° 70 100 45° 130 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ 3.7 2.1 1.3 0.9 0.7 0.5 0.4 0.3 Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 49.1% Spacing Criteria 2.0 Certificate S0605102 80 50 30 58 58 45 42 35 31 28 23 23 18 19 15 50 50 30 55 55 43 40 33 30 27 23 22 18 18 15 30 50 30 52 52 41 39 32 29 26 22 21 18 18 14 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Magn. DTT - Champagne Reflector CANDLEPOWER DISTRIBUTION Candelas 90° 25 75° 45 60° 65 85 45° 105 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC DIA 3.0 1.7’ 1.7 2.3’ 1.1 2.9’ 0.8 3.5’ 0.6 4.0’ 0.4 4.6’ 0.3 5.2’ 0.3 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 40.6% Spacing Criteria 2.0 Certificate S0605103 80 50 30 48 48 38 35 29 26 23 19 19 15 16 12 50 50 30 45 45 35 33 28 25 22 19 18 15 15 12 30 50 30 43 43 34 32 27 24 21 19 17 15 15 12 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 473 FLUO 4” F2450VT Downlight F2450VT-04BR-WFF04 Damp location Compact fluorescent: 1 X CFQ-18W 1 X CFQ-26W 1 X CFTR-18W 1 X CFTR-26W 1 X CFTR-32W ** Lamps must meet ANSI requirements.** 3 5/16" 84mm 1/8" 3mm Glass Tube Colors Available in 7 different colors. Ex.: F2450VT-01-NFF07 COLORS Eggplant Blue Green Amber Natural Red White CODES -A -B -G -M -N -R -W 3" 4" Glass Tube Textures 5" Available in 2 different textures. Ex.: F2450VT-01-NFF07 TEXTURES CODES 3" à 7" 76 à 178mm 6" Clear Frosted int./ext. C FF 7" 3" 76mm 4 7/8" 124mm Glass Tube Lengths Available in 5 different lengths. Ex.: F2450VT-01-NFF07 LENGTHS 3” (76mm) 4” (102mm) 5” (127mm) 6” (152mm) 7” (178mm) 03 04 05 06 07 CODES 3" 76mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: F2450VT-02-NFF06 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F2450VT-11MG-RC03 474 www.contrastlighting.com F2450VT Vertical Technical Specifications Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF2000LU26EM Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Dimming Capability • 120V: For dimming capability, change «U» Housing Features to «D» in codes of housing of 18W to 42W. • Galvanized steel Ex.: F2000LD18 • Below ceiling accessible • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F2000LD182 F2450VT Trim codification Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2000LU18W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2000LU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Specs and codification F2450VT-04BR-WFF03 MODEL TRIM FINISH GLASS COLOR GLASS TEXTURE GLASS LENGTH F2450VT -04BR -W FF 03 -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -A -B -G -M -N -R -W Eggplant Cobalt Blue Green Amber Naturel Red White FF Frosted int./ext. C Clear 03 04 05 06 07 3” 4” 5” 6” 7” of of of of of the the the the the trim trim trim trim trim Housings Specifications New Construction (NW) Code NWF2000LU18 NWF2000LU18 NWF2000LU32 NWF2000LU32 Lamp 1 X 18W 1 X 18W 1 X 26W 1 X 26/32W DTT TTT DTT TTT Base G24q-2 GX24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L 1411/16” 1411/16” 1411/16” 1411/16” W X X X X 10” 10” 10” 10” H X X X X 71/4” 71/4” 71/4” 71/4” Hole Cut : 41/4” Remodel Code F2000LU18 F2000LU32 F2000LU32 Lamp 1 X 18W TTT 1 X 26W DTT 1 X 26/32W TTT Base GX24q-2 (4 pin) G24q-3 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L 1311/16” 1311/16” 1311/16” W X X X 51/8” 51/8” 51/8” H X X X 71/4” 71/4” 71/4” Hole Cut : 41/4” Insulated Ceiling (IC)1 Code 1 ISF2000LU18 Lamp 1 X 18W TTT Base GX24q-2 (4 pin) Volts 120-277V Ballast Electronic L 193/8” W X 10” H X 61/16” Hole Cut : 41/4” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 475 FLUO 4” F2575R Downlight F2575R Vertical Damp location Compact fluorescent: 1 X CFQ-13W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Champagne finish: Add «CH» after the housing code. Ex.: F2575RCH Housings Specifications 415/16” 125mm Remodel Code F2575R Lamp 1 X 13W DTT Base GX23-2 (2 pin) Volts 120V Ballast L HPF Magn. 143/4” W X 59/16” H X 6” Hole Cut : 45/8” **TRIM NOT REQUIRED** 149/16” 370mm Insulated Ceiling (IC)1 Code 1 ISF2575R Lamp 1 X 13W DTT **TRIM NOT REQUIRED** Airtight - ASTM#283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Housing finishes -01 White Ex.: F2575R 476 www.contrastlighting.com Base GX23-2 (2 pin) Volts 120V Ballast L HPF Magn. 153/16” W X 81/8” Hole Cut : 45/8” 515/16” 151mm H X 71/2” ø 57/16” 138mm F2575R Vertical Technical Specifications Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent champagne finish. Add «CH» to housing code. Ex: F2575RCH Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2575RP Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2575RW 4” FLUO 120V Class P, HPF Magnetic ballast • Instant start • 2 year warranty Photometric Data 13W Magn. DTT - Clear Reflector CANDLEPOWER DISTRIBUTION Candelas 90° 35 75° 65 60° 95 125 45° 155 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 4.3 2.4 1.6 1.1 0.8 0.6 0.5 0.4 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 59.4% Spacing Criteria 2.4 Certificate S0604264 80 50 30 71 71 54 50 41 36 33 27 26 21 22 17 50 50 30 66 66 51 48 39 35 31 26 25 21 21 16 30 50 30 63 63 49 46 38 34 30 26 24 20 20 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 13W Magn. DTT - Champagne Reflector CANDLEPOWER DISTRIBUTION Candelas 90° 15 75° 45 60° 75 105 45° 135 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 3.7 2.1 1.3 0.9 0.7 0.5 0.4 0.3 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 2pin 780 120V Input Watts 16W Operating AMPS 0.13A Luminaire Efficiency 50.8% Spacing Criteria 2.4 Certificate S0604265 80 50 30 61 61 46 43 35 31 28 23 22 18 19 14 50 50 30 56 56 44 41 33 30 26 22 21 17 18 14 30 50 30 54 54 42 40 32 29 26 22 21 17 17 14 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 477 FLUO 4” F2575RU Downlight F2575RU-01 Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the housing code. Ex.: F2575RU13M Housings Specifications 5” 127mm New Construction (NW) Code NWF2575RU13 NWF2575RU18 NWF2575RU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L 1411/16” 1411/16” 1411/16” W X X X 10” 10” 10” H X X X 75/8” 75/8” 75/8” Hole Cut : 45/8” **TRIM NOT REQUIRED** 14” 355mm Remodel Code F2575RU13 F2575RU18 F2575RU26 Lamp 1 X 13W 1 X 18W 1 X 26W DTT TTT TTT **TRIM NOT REQUIRED** Housing finishes -01 White Ex.: F2575RU18-01 478 www.contrastlighting.com Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L 143/16” 143/16” 143/16” W X X X 59/16” 59/16” 59/16” Hole Cut : 45/8” 71/16” 180mm H X X X 71/16” 71/16” 71/16” ø 51/2” 140mm F2575R Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2575RD18 • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: F2575RD182 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Reflector from trusses or suspended ceilings. 0.04’’aluminium reflector with low iridescence semi specular Housing Features clear finish. • Galvanized steel Optional: Low iridescent matte • Below ceiling accessible finish. Add «M» to housing code. • See specs in Housing Section Ex: F2575RU18M Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: AvailableA in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 40 75° 80 60° 120 160 45° 200 0° 15° 30° CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 71.8% Spacing Criteria 2.4 Certificate S0601131 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Triple Tube, 4 pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 76.8% Spacing Criteria 2.3 Certificate S060113 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.4 3.0 1.9 1.3 1.0 0.8 0.6 0.5 DIA 2.1’ 2.9’ 3.6’ 4.3’ 5.0’ 5.7’ 6.4’ 7.1’ 80 50 30 86 86 64 59 49 42 38 32 31 25 26 20 50 50 30 80 80 60 56 46 41 36 31 30 24 25 19 30 50 30 76 75 58 55 44 40 35 30 29 24 24 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 60 75° 120 60° 180 245 45° 300 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 8.4 4.7 3.0 2.1 1.5 1.2 0.9 0.8 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ 80 50 30 91 91 71 65 54 47 43 36 35 28 29 22 50 50 30 85 85 66 62 51 46 41 35 33 27 28 22 30 50 30 82 82 64 61 49 45 39 34 32 27 27 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 75 75° 155 60° 230 310 45° 385 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 10.6 6.0 3.8 2.7 1.9 1.5 1.2 1.0 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Triple Tube, 4 pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 68.2% Spacing Criteria 2.3 Certificate S0601161 Matte Reflector 0.83 Multiplier 80 50 30 81 81 62 57 47 41 37 31 30 24 25 19 50 50 30 76 76 58 54 44 39 35 30 29 23 24 19 30 50 30 73 73 56 53 43 38 34 29 28 23 23 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 479 HID FLUO GX10 4”1/2” 3 FB2675 finitions Downlight FB2675-08 Vertical modèle Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W 1 X CFTR-32W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the housing code. Ex.: FB2675RU18M Housings Specifications 9/16” 14mm New Construction (NW) Code NWF2675RU13 NWF2675RU18 NWF2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X H 10” 10” 10” X X X 75/8” 75/8” 75/8” Hole Cut : 45/8” Remodel Code F2675RU13 F2675RU18 F2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 6” 152mm H 59/16” 59/16” 59/16” X X X 71/16” 71/16” 71/16” Hole Cut : 45/8” ø 41/8” 105mm Insulated Ceiling (IC)1 Code 1 ISF2675RU13 1 ISF2675RU18 1 ISF2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 193/8” 193/8” 193/8” X X X H 10” 10” 10” X X X 61/16” 61/16” 61/16” Hole Cut : 45/8” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FB2675-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FB2675-11MG 480 www.contrastlighting.com FB2675 Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF2575RD18 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF2575RD182 Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • See specs in Housing Section Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: F2675RU18M Trims Plated or painted steel Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 45 75° 85 60° 130 170 45° 215 0° 15° 30° CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 70.4% Spacing Criteria 1.9 Certificate S0601132 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 73.3% Spacing Criteria 1.8 Certificate S0601134 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 71.1% Spacing Criteria 1.9 Certificate S0601162 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.9 3.3 2.1 1.5 1.1 0.8 0.7 0.5 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ 80 50 30 84 84 65 60 50 44 40 34 33 27 28 22 50 50 30 78 78 61 58 48 43 38 33 32 26 27 22 30 50 30 75 75 59 56 46 42 37 32 31 26 26 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 70 75° 145 60° 215 285 45° 355 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 9.8 5.5 3.5 2.4 1.8 1.4 1.1 0.9 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ 80 50 30 92 92 73 69 58 51 46 40 38 32 32 26 50 50 30 86 86 69 66 55 50 44 39 36 31 31 25 30 50 30 82 82 67 64 53 49 43 38 36 30 30 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90 75° 180 60° 270 360 45° 450 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 12.4 7.0 4.5 3.1 2.3 1.7 1.4 1.1 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ 80 50 30 85 85 66 61 51 45 41 35 34 28 28 23 50 50 30 79 79 62 59 49 44 39 34 32 27 27 22 30 50 30 76 76 60 57 47 43 38 33 31 27 27 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 100 75° 200 60° 300 400 45° 500 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 13.9 7.8 5.0 3.5 2.6 2.0 1.5 1.3 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 63.5% Spacing Criteria 1.9 Certificate S0601171 Matte Reflector 0.83 Multiplier 80 50 30 76 76 58 54 45 39 36 30 29 24 24 19 50 50 30 71 71 54 51 52 38 34 29 28 23 23 19 30 50 30 68 68 52 50 41 37 33 29 27 23 23 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 481 FLUO 4” FC2675 Downlight FC2675-13 Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the housing code. Ex.: F2675RU13M Housings Specifications New Construction (NW) Code NWF2675RU13 NWF2675RU18 NWF2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 1411/16” 1411/16” 1411/16” X X X 3/16” 4mm H 10” 10” 10” X X X 75/8” 75/8” 75/8” Hole Cut : 45/8” Remodel Code F2675RU13 F2675RU18 F2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 511/16” 145mm H 59/16” 59/16” 59/16” X X X 71/16” 71/16” 71/16” Hole Cut : 45/8” 45/16” 45/8” 109mm 117mm Insulated Ceiling (IC)1 Code 1 ISF2675RU13 1 ISF2675RU18 1 ISF2675RU32 Lamp 1 X 13W DTT 1 X 18W TTT 1 X 26/32W TTT Base G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 193/8” 193/8” 193/8” X X X H 10” 10” 10” X X X 61/16” 61/16” 61/16” Hole Cut : 45/8” Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 1 Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FC2675-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FC2675-14MG 482 www.contrastlighting.com FC2675 Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F2675RD32 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F2675RD322 Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: F2675RU18M Trims Plated or painted steel Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM E283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P 4” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 40 75° 80 60° 120 160 45° 200 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 71.8% Spacing Criteria 2.4 Certificate S0601131 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Triple Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 76.8% Spacing Criteria 2.3 Certificate S0601133 Matte Reflector 0.83 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 5.4 3.0 1.9 1.3 1.0 0.8 0.6 0.5 DIA 2.1’ 2.9’ 3.6’ 4.3’ 5.0’ 5.7’ 6.4’ 7.1’ 80 50 30 86 86 64 59 49 42 38 32 31 25 26 20 50 50 30 80 80 60 56 46 41 36 31 30 24 25 19 30 50 30 76 76 58 55 44 40 35 30 29 24 24 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 18W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 60 75° 120 60° 180 245 45° 300 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 8.4 4.7 3.0 2.1 1.5 1.2 0.9 0.8 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ 80 50 30 91 91 71 65 54 47 43 36 35 28 29 22 50 50 30 85 85 66 62 51 46 41 35 33 27 28 22 30 50 30 82 82 64 61 49 45 39 34 32 27 27 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 75 75° 155 60° 230 310 45° 385 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 10.6 6.0 3.8 2.7 1.9 1.5 1.2 1.0 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 68.2% Spacing Criteria 2.3 Certificate S0601161 Matte Reflector 0.83 Multiplier 80 50 30 81 81 62 57 47 41 37 31 30 24 25 19 50 50 30 76 76 58 54 44 39 35 30 29 23 24 19 30 50 30 73 73 56 53 43 38 34 29 28 23 23 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 483 Compact Fluorescent Energy Efficient Lighting 6” FLUO 6” FR6HO Downlight FR6HO-11 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOM-12BR Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13 NWF6HU18 NWF6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 3/16” 5mm 73/16” 73/16” 73/16” Hole Cut : 63/4” Remodel Code F6HU13 F6HU18 F6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 141/8” 141/8” 141/8” X X X ø 8” 203mm H 8” 8” 8” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HO-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOM-14MG 486 www.contrastlighting.com FR6HO 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: FR6HOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 120 75° 240 60° 360 480 45° 600 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower Two 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 63% Spacing Criteria 1.4 (0-180) 1.6 (90-270) Certificate S0612054R1 Matte Reflector 0.80 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower Two 18W Quad, 4pin 2400 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 62% Spacing Criteria 1.4 (0-180) 1.6 (90-270) Certificate S0612064R1 Matte Reflector 0.80 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 16.5 9.3 5.9 4.1 3 2.3 1.8 1.5 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ 80 50 30 76 76 60 56 48 43 39 34 33 27 28 23 50 50 30 71 71 57 54 46 42 37 33 31 27 27 22 30 50 30 65 65 53 51 43 40 35 32 30 26 28 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 150 75° 300 60° 450 600 45° 750 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 20.4 11.5 7.3 5.1 3.7 2.9 2.3 1.8 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ 80 50 30 74 74 59 55 47 42 38 33 32 27 27 22 50 50 30 69 69 55 52 44 40 36 32 30 26 26 22 30 50 30 63 63 51 49 42 39 34 31 29 25 25 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 220 75° 440 60° 660 880 45° 1100 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 29.1 16.4 10.5 7.3 5.3 4.1 3.2 2.6 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4’ Beam Edge defined as 50% of Maximum Nadir Candlepower Two 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 67% Spacing Criteria 1.4 (0-180) 1.6 (90-270) Certificate S0612074R1 Matte Reflector 0.80 Multiplier 80 50 30 80 80 63 59 50 45 41 35 34 28 29 23 50 50 30 75 75 59 56 48 43 39 34 32 28 28 23 30 50 30 69 69 55 53 45 41 37 33 31 27 26 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 487 FLUO 6” FR6HO Downlight FR6HO-11 1 x DTT/TTT Horizontal Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** 1 X CFTR-32W Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOM-12BR Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13S NWF6HU18S NWF6HU26S NWF6HU32S Lamp 1 X 13W 1 X 18W 1 X 26W 1 X 32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 191/8” 191/8” 191/8” 191/8” X X X X H 10” 10” 10” 10” X X X X 3/16” 5mm 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13S F6HU18S F6HU26S F6HU32S Lamp 1 X 13W 1 X 18W 1 X 26W 1 X 32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 141/8” 141/8” 141/8” 141/8” X X X X H 8” 8” 8” 8” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HO-13 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOM-01MG 488 www.contrastlighting.com FR6HO 1 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: FR6HOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 85 75° 170 60° 255 340 45° 425 0° 15° 30° CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 77.6% Spacing Criteria 0.8 (0-180) 1(90-270) Certificate S0612051R1 Matte Reflector 0.76 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 75.8% Spacing Criteria 1 (0-180) 1.1 (90-270) Certificate S0612061R1 Matte Reflector 0.76 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 71.1% Spacing Criteria 1.1 (0-180) 1.1 (90-270) Certificate S0612071R1 Matte Reflector 0.76 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 11.3 6.3 4.1 2.8 2.1 1.6 1.3 1 DIA 0.6’ 0.8’ 1’ 1.2’ 1.3’ 1.5’ 1.7’ 1.9’ 80 50 30 92 92 72 68 58 52 48 41 40 34 35 29 50 50 30 86 86 68 64 55 50 46 40 39 33 33 28 30 50 30 79 79 63 61 52 48 43 39 37 32 32 28 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 100 75° 200 60° 300 400 45° 500 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 13.6 7.6 4.9 3.4 2.5 1.9 1.5 1.2 DIA 0.6’ 0.8’ 1’ 1.2’ 1.3’ 1.5’ 1.7’ 1.9’ 80 50 30 90 90 71 66 57 51 47 40 39 33 34 28 50 50 30 84 84 67 63 54 49 44 39 38 32 32 27 30 50 30 77 77 62 60 50 47 42 38 36 31 31 27 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 130 75° 260 60° 390 520 45° 650 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 17.7 10 6.4 4.4 3.3 2.5 2 1.6 DIA 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ 80 50 30 85 85 66 61 52 46 43 36 36 30 30 25 50 50 30 79 79 62 58 49 45 41 35 34 29 29 25 30 50 30 72 72 57 55 46 43 38 34 32 28 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 220 75° 440 60° 660 880 45° 1100 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 29.5 16.6 10.6 7.4 5.4 4.1 3.3 2.7 DIA 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 84% Spacing Criteria 1.1 (0-180) 1.1 (90-270) Certificate S0612081R1 Matte Reflector 0.76 Multiplier 80 50 30 101 101 80 75 64 57 52 45 44 37 38 31 50 50 30 94 94 75 71 61 55 50 44 42 36 36 31 30 50 30 86 86 70 67 57 53 47 43 40 35 35 30 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 489 FLUO 6” FR6HOLA Downlight FR6HOLA-01 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13 NWF6HU18 NWF6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 13/16” 73/16” 73/16” 73/16” 30mm Hole Cut : 63/4” Remodel Code F6HU13 F6HU18 F6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 141/8” 141/8” 141/8” X X X ø 8” 203mm H 8” 8” 8” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOLA-12BR For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLA-06MG 490 www.contrastlighting.com FR6HOLA 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD262 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26EM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 60 75° 120 60° 180 240 45° 300 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 7.9 4.4 2.8 2 1.4 1.1 0.9 0.7 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 51% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0612055R1 80 50 30 60 60 45 41 35 30 28 23 23 18 19 15 50 50 30 54 54 41 38 32 28 25 22 21 17 18 14 30 50 30 48 48 36 34 28 25 23 22 19 16 16 13 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 75 75° 150 60° 225 300 45° 375 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 9.8 5.5 3.5 2.5 1.8 1.4 1.1 0.9 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 18W Quad, 4pin 2400 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 52% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0612065R1 80 50 30 61 61 45 42 35 30 28 23 23 19 19 15 50 50 30 55 55 41 38 32 28 26 22 21 17 18 14 30 50 30 48 48 36 34 28 26 23 20 19 16 16 13 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 110 75° 220 60° 330 440 45° 550 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 15.2 8.6 5.5 3.8 2.8 2.1 1.7 1.4 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 57% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0612076R1 80 50 30 66 66 49 45 38 33 30 25 25 20 21 16 50 50 30 60 60 44 41 34 30 28 23 23 19 19 15 30 50 30 52 52 39 37 30 27 25 21 20 17 17 14 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 491 FLUO 6” FR6HOLA Downlight FR6HOLA-01 1 x DTT/TTT Horizontal Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** 1 X CFTR-32W Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13S NWF6HU18S NWF6HU26S NWF6HU32S Lamp 1 X 13W 1 X 18W 1 X 26W 1 X 32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 191/8” 191/8” 191/8” 191/8” X X X X H 10” 10” 10” 10” X X X X 13/16” 73/16” 73/16” 73/16” 73/16” 30mm Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13S F6HU18S F6HU26S F6HU32S Lamp 1 X 13W 1 X 18W 1 X 26W 1 X 32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 141/8” 141/8” 141/8” 141/8” X X X X H 8” 8” 8” 8” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOLA-04BR For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLA-05MG 492 www.contrastlighting.com FR6HOLA 1 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 40 75° 80 60° 120 160 45° 200 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 4.9 2.8 1.8 1.2 0.9 0.7 0.5 0.4 DIA 3.7’ 5’ 6.2’ 7.5’ 8.7’ 10’ 11.2’ 12.4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 61% Spacing Criteria 1.1 (0-180) 1.2 (90-270) Certificate S0612052R1 80 50 30 72 72 54 49 41 36 33 27 27 22 23 18 50 50 30 66 66 49 45 38 33 31 26 25 21 22 17 30 50 30 58 58 44 41 34 31 28 24 23 20 20 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 50 75° 100 60° 150 200 45° 250 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 6.5 3.7 2.4 1.6 1.2 0.9 0.7 0.6 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 60% Spacing Criteria 1.3 (0-180) 1.2 (90-270) Certificate S0612062R1 80 50 30 70 70 52 48 40 35 32 27 26 21 22 18 50 50 30 64 64 47 44 37 32 30 25 25 20 21 17 30 50 30 57 57 42 40 33 30 27 23 22 19 19 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 70 75° 140 60° 210 280 45° 350 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 7.7 4.3 2.8 1.9 1.4 1.1 0.9 0.7 DIA 5.7’ 7.6’ 9.5’ 11.3’ 13.2’ 15.1’ 17’ 18.9’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 60% Spacing Criteria 1.4 (0-180) 1.2 (90-270) Certificate S0612072R1 80 50 30 71 71 52 47 40 34 32 26 26 21 22 17 50 50 30 64 64 47 44 36 32 29 24 24 20 20 16 30 50 30 57 57 42 39 32 29 26 23 22 18 19 15 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 105 75° 210 60° 315 420 45° 525 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 14 7.9 5 3.5 2.6 2.0 1.6 1.3 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 69% Spacing Criteria 1.2 (0-180) 1.2 (90-270) Certificate S0612082R1 80 50 30 81 81 60 55 46 40 37 31 31 25 26 20 50 50 30 73 73 55 51 42 37 34 29 28 23 24 19 30 50 30 65 65 49 46 38 34 31 27 26 22 22 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 493 FLUO 6” FR6HOLB Downlight FR6HOLB-01 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13 NWF6HU18 NWF6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 13/16” 73/16” 73/16” 73/16” 30mm Hole Cut : 63/4” Remodel Code F6HU13 F6HU18 F6HU26 Lamp 2 X 13W 2 X 18W 2 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 141/8” 141/8” 141/8” X X X ø 8” 203mm H 8” 8” 8” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOLB-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLB-11MG 494 www.contrastlighting.com FR6HOLB 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD262 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26EM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 75 75° 150 60° 225 300 45° 375 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 10.1 5.7 3.6 2.5 1.9 1.4 1.1 0.9 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 55% Spacing Criteria 1.2 (0-180) 1.3 (90-270) Certificate S0612056R1 80 50 30 65 65 49 46 39 34 31 26 26 21 22 18 50 50 30 59 59 45 42 35 32 29 25 24 20 21 17 30 50 30 52 52 40 38 32 29 26 23 22 19 19 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 95 75° 190 60° 285 380 45° 475 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 12.9 7.3 4.7 3.2 2.4 1.8 1.4 1.2 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 18W Quad, 4pin 2400 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 56% Spacing Criteria 1.2 (0-180) 1.3 (90-270) Certificate S0612066R1 80 50 30 65 65 49 46 39 34 31 26 26 21 22 18 50 50 30 59 59 45 42 35 31 29 25 24 20 20 17 30 50 30 52 52 40 38 31 29 26 23 22 19 19 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 140 75° 280 60° 420 560 45° 700 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 18.8 10.5 6.8 4.7 3.4 2.6 2.1 1.7 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 60% Spacing Criteria 1.2 (0-180) 1.3 (90-270) Certificate S0612077R1 80 50 30 70 70 53 49 41 36 33 28 27 22 23 19 50 50 30 63 63 48 45 38 33 31 26 25 21 22 18 30 50 30 56 56 42 40 33 30 27 24 23 20 20 17 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 495 FLUO 6” FR6HOLB Downlight FR6HOLB-01 1 x DTT/TTT Horizontal Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** 1 X CFTR-32W Reflector Standard: semi-specular low iridescence aluminum 11/2” 38mm Housings Specifications 53/4” 146mm New Construction (NW) Code NWF6HU13S NWF6HU18S NWF6HU26S NWF6HU32S Lamp 1x13W 1X18W 1X26W 1X32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 191/8” 191/8” 191/8” 191/8” X X X X H 10” 10” 10” 10” X X X X 13/16” 73/16” 73/16” 73/16” 73/16” 30mm Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13S F6HU18S F6HU26S F6HU32S Lamp 1x13W 1X18W 1X26W 1X32W DTT DTT DTT TTT Base G24q-1 G24q-2 G24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 141/8” 141/8” 141/8” 141/8” X X X X H 8” 8” 8” 8” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOLB-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLB-05MG 496 www.contrastlighting.com FR6HOLB 1 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 55 75° 110 60° 165 220 45° 275 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 7 4 2.5 1.8 1.3 1 0.8 0.7 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 66% Spacing Criteria 0.9 (0-180) 0.9 (90-270) Certificate S0612053R1 80 50 30 77 77 58 54 46 40 37 31 31 26 26 21 50 50 30 71 71 53 50 42 38 35 30 29 24 25 21 30 50 30 63 63 48 46 38 35 32 28 27 23 23 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 65 75° 130 60° 195 260 45° 325 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 8.8 4.9 3.2 2.2 1.6 1.2 1 0.8 DIA 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 60% Spacing Criteria 0.9 (0-180) 1.0 (90-270) Certificate S0612063R1 80 50 30 72 72 54 50 42 37 34 29 29 24 24 20 50 50 30 67 67 51 47 40 35 33 28 27 23 24 19 30 50 30 62 62 47 44 37 34 31 27 26 22 22 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90 75° 180 60° 270 360 45° 450 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 11.7 6.6 4.2 2.9 2.1 1.6 1.3 1.1 DIA 0.8’ 1.1’ 1.4’ 1.7’ 2’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 63% Spacing Criteria 1.1 (0-180) 1.0 (90-270) Certificat S0612073R1 80 50 30 74 74 55 51 43 37 35 29 29 24 25 20 50 50 30 68 68 51 47 40 35 32 28 27 22 23 19 30 50 30 60 60 45 43 36 32 29 26 25 21 21 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 140 75° 280 60° 420 560 45° 700 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 18.6 10.5 6.7 4.6 3.4 2.6 2.1 1.7 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 71% Spacing Criteria 1.0 (0-180) 1.0 (90-270) Certificate S0612084R1 80 50 30 84 84 63 58 50 43 40 34 33 28 29 23 50 50 30 76 76 58 54 46 41 37 32 31 26 27 22 30 50 30 68 68 52 49 41 38 34 30 29 25 25 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 497 FLUO 6” FR6HOW90 90° Wall Wash FR6HOW90-04BR 2 x DTT/TTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** 2 X CFTR-26W Reflector Standard: semi-specular low iridescence aluminum 13/8” 35mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW90M-12BR Housings Specifications New Construction (NW) Code NWF6HU13 NWF6HU18 NWF6HU26 Lamp 2X13W DTT 2X18W DTT 2X26W DTT/TTT Base Volts (4 pin) 120-277V G24q-1 (4 pin) 120-277V G24q-2 G24q-3/GX24q-3 (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X 57/8” 149mm H 10” 10” 10” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13 F6HU18 F6HU26 Lamp 2X13W DTT 2X18W DTT 2X26W DTT/TTT Base Volts (4 pin) 120-277V G24q-1 (4 pin) 120-277V G24q-2 G24q-3/GX24q-3 (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 141/8” 141/8” 141/8” X X X H 8” 8” 8” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOW90-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW90-01MG 498 www.contrastlighting.com FR6HOW90 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD262 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26EM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6HOMW90 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 115 75° 75° 230 60° 60° 340 45° 45° 455 30° 90° 15° 570 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 65% Spacing Criteria 1.2 (0-180) 1.6 (90-270) Certificate S0806021R1 30° 80 50 30 78 78 61 57 48 43 39 33 32 27 26 22 50 50 30 73 73 57 54 46 41 37 32 31 26 26 22 10 50 30 67 67 53 51 43 39 35 31 29 26 25 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 145 75° 75° 295 60° 60° 440 45° 45° 585 30° 90° 15° 730 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 2400 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 63% Spacing Criteria 1.2 (0-180) 1.6 (90-270) Certificate S0805301R1 30° 80 50 30 75 75 59 55 47 42 38 33 31 26 27 22 50 50 30 70 70 56 53 44 40 36 32 30 26 26 21 10 50 30 64 64 52 50 42 39 34 31 29 25 25 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 185 75° 75° 370 60° 60° 560 45° 45° 745 30° 90° 15° 930 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 58% Spacing Criteria 1.3 (0-180) 1.5 (90-270) Certificate S0805272R1 30° 80 50 30 68 68 54 50 43 38 35 30 29 24 24 20 50 50 30 64 64 51 48 41 37 33 29 28 24 24 20 10 50 30 59 59 47 45 38 35 31 28 26 23 22 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 2 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 220 75° 75° 440 60° 45° 90° 60° 660 45° 880 30° 15° 0° 1100 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 60% Spacing Criteria 1.1 (0-180) 1.7 (90-270) Certificate S0805281R1 80 50 30 72 72 56 53 45 40 36 31 30 25 25 21 50 50 30 67 67 53 50 42 38 35 30 29 25 25 20 10 50 30 61 61 50 48 40 37 33 29 27 24 23 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 499 FLUO 6” FR6HOW90 90° Wall Wash FR6HOW90-04BR 1 x DTT/TTT Horizontal Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** 1 X CFTR-32W Reflector Standard: semi-specular low iridescence aluminum 13/8” 35mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW90M-12BR Housings Specifications New Construction (NW) Code NWF6HU13S NWF6HU18S NWF6HU26S NWF6HU32S Lamp 1X13W 1X18W 1X26W 1X32W DTT DTT TTT TTT Base G24q-1 G24q-2 GX24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 191/8” 191/8” 191/8” 191/8” X X X X 57/8” 149mm H 10” 10” 10” 10” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13S F6HU18S F6HU26S F6HU32S Lamp 1X13W 1X18W 1X26W 1X32W DTT DTT TTT TTT Base G24q-1 G24q-2 GX24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 141/8” 141/8” 141/8” 141/8” X X X X H 8” 8” 8” 8” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOW90-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW90-01MG 500 www.contrastlighting.com FR6HOW90 1 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6HOMW90 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 80 75° 75° 155 60° 60° 235 45° 90° 45° 315 30° 15° 390 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 71% Spacing Criteria 1.3 (0-180) 1.1 (90-270) Certificate S0806024R1 80 50 30 85 85 67 62 53 47 44 38 37 31 32 26 50 50 30 79 79 63 60 51 46 42 37 35 30 31 26 10 50 30 73 73 59 56 47 44 40 36 34 30 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 90 75° 75° 185 60° 60° 275 45° 45° 370 30° 90° 15° 460 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 67% Spacing Criteria 1.3 (0-180) 1.1 (90-270) Certificate S0805304R1 30° 80 50 30 80 80 63 59 50 45 41 36 35 29 30 25 50 50 30 75 75 60 56 48 43 39 35 33 29 29 24 10 50 30 69 69 55 53 45 42 37 33 32 28 27 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 150 75° 75° 295 60° 60° 445 45° 90° 45° 595 30° 15° 740 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 72% Spacing Criteria 1.2 (0-180) 1.1 (90-270) Certificate S0805294R1 80 50 30 86 86 68 63 54 48 44 38 37 32 32 27 50 50 30 80 80 64 61 51 47 42 37 36 31 31 26 10 50 30 74 74 59 57 48 45 40 36 34 30 30 26 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 220 75° 75° 440 60° 45° 90° 60° 660 45° 880 30° 15° 1100 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 81% Spacing Criteria 1.2 (0-180) 1.2 (90-270) Certificate S0805293R1 80 50 30 96 96 76 71 60 54 49 43 41 35 36 29 50 50 30 90 90 72 68 57 52 47 42 40 34 34 29 10 50 30 83 83 67 64 54 50 45 40 38 33 33 28 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 501 FLUO 6” FR6HOW120 120° Wall Wash FR6HOW120-01 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum 13/8” 35mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW120M-12BR Housings Specifications New Construction (NW) Code NWF6HU13 NWF6HU18 NWF6HU26 Lamp 2X13W 2X18W 2X26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X 57/8” 149mm H 10” 10” 10” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13 F6HU18 F6HU26 Lamp 2X13W 2X18W 2X26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 141/8” 141/8” 141/8” X X X H 8” 8” 8” X X X 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOW120-02 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW120-02MG 502 www.contrastlighting.com FR6HOW120 2 x DTTHorizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD262 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26EM Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: F2675RU18M Trims Plated or painted steel Efficient CFL Housings Socket & Lamp Bases High temperature-rated 130˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM#283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 105 75° 75° 215 60° 60° 320 45° 45° 425 30° 90° 15° 530 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 62% Spacing Criteria 1.2 (0-180) 1.5 (90-270) Certificate S0806022R1 30° 80 50 30 74 74 57 54 45 40 37 31 30 25 26 21 50 50 30 69 69 54 51 43 39 35 30 29 25 25 20 10 50 30 63 63 50 48 40 37 33 29 28 24 24 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 140 75° 75° 280 60° 60° 420 45° 45° 560 30° 90° 15° 700 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 2400 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 64% Spacing Criteria 1.2 (0-180) 1.5 (90-270) Certificate S0805302R1 30° 80 50 30 76 76 59 55 47 42 38 32 31 26 27 22 50 50 30 71 71 56 53 44 40 36 32 30 26 26 21 10 50 30 65 65 52 50 42 38 34 31 29 25 25 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 180 75° 75° 360 60° 60° 540 45° 90° 45° 720 30° 15° 900 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 57% Spacing Criteria 1.3 (0-180) 1.5 (90-270) Certificat S0805271R1 80 50 30 68 68 53 50 42 37 34 29 28 24 24 20 50 50 30 64 64 50 47 40 36 32 28 27 23 23 19 10 50 30 59 59 47 45 37 34 31 27 26 22 22 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 503 FLUO 6” FR6HOW120 120° Wall Wash FR6HOW120-01 1 x DTT/TTT Horizontal Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFTR-26W ** Lamps must meet ANSI requirements.** 1 X CFTR-32W Reflector Standard: semi-specular low iridescence aluminum 13/8” 35mm Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW120M-12BR Housings Specifications New Construction (NW) Code NWF6HU13S NWF6HU18S NWF6HU26S NWF6HU32S Lamp 1X13W 1X18W 1X26W 1X32W DTT DTT TTT TTT Base G24q-1 G24q-2 GX24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 191/8” 191/8” 191/8” 191/8” X X X X 57/8” 149mm H 10” 10” 10” 10” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” ø 8” 203mm Remodel Code F6HU13S F6HU18S F6HU26S F6HU32S Lamp 1X13W 1X18W 1X26W 1X32W DTT DTT TTT TTT Base G24q-1 G24q-2 GX24q-3 GX24q-3 (4 (4 (4 (4 pin) pin) pin) pin) Volts 120-277V 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic Electronic L W 141/8” 141/8” 141/8” 141/8” X X X X H 8” 8” 8” 8” X X X X 73/16” 73/16” 73/16” 73/16” Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6HOW120-02 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW120-02MG 504 www.contrastlighting.com FR6HOW120 1 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6HD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6HD26S2 Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6HD26SEM Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6HOMW120 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 75 75° 75° 150 60° 60° 225 45° 90° 45° 295 30° 15° 370 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 70% Spacing Criteria 1.2 (0-180) 0.9 (90-270) Certificate S0806023R1 80 50 30 83 83 64 60 51 45 42 36 35 30 31 25 50 50 30 77 77 61 57 48 44 40 35 34 29 29 25 10 50 30 71 71 56 54 45 42 38 34 32 28 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 90 75° 75° 180 60° 60° 270 45° 45° 360 30° 90° 15° 450 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 66% Spacing Criteria 1.3 (0-180) 1.0 (90-270) Certificate S0805303R1 30° 80 50 30 79 79 61 57 49 43 40 34 34 28 29 24 50 50 30 73 73 58 55 46 42 38 33 32 28 28 23 10 50 30 67 67 54 52 43 40 36 32 31 27 27 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 150 75° 75° 300 60° 60° 450 45° 90° 45° 600 30° 15° 750 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 70% Spacing Criteria 1.2 (0-180) 1.0 (90-270) Certificate S0805291R1 80 50 30 83 83 65 61 52 46 42 37 36 30 31 26 50 50 30 78 78 61 58 49 44 41 36 34 30 30 25 10 50 30 72 72 57 55 46 43 38 34 33 29 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 180 75° 75° 355 60° 45° 90° 60° 535 45° 715 30° 15° 890 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 69% Spacing Criteria 1.2 (0-180) 1.1 (90-270) Certificate S0805292R1 80 50 30 82 82 64 60 51 45 42 36 35 29 30 25 50 50 30 76 76 60 57 48 44 40 35 34 29 29 24 10 50 30 70 70 56 54 45 42 38 34 32 28 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 505 FLUO 6” FR6VO Downlight FR6VO-11 1 x DTT Narrow Flood Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-08 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W Base DTT G24q-1 DTT G24q-2 DTT/TTT G24q-3 Volts (4 pin) 120-277V (4 pin) 120-277V (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VO-13 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-14MG 506 www.contrastlighting.com FR6VO 1 x DTT Narrow Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 180 75° 360 60° 540 720 45° 900 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 24.3 13.7 8.8 6.1 4.5 3.4 2.7 2.2 0.4’ 0.5’ 0.6’ 0.7’ 0.8’ 1’ 1.1’ 1.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 75% Spacing Criteria 0.6 Certificate S0611231R1 Matte Reflector 0.82 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 72% Spacing Criteria 0.6 Certificate S0611244R1 Matte Reflector 0.82 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 90 90 77 74 67 62 58 53 51 46 45 41 50 50 30 84 84 74 71 64 61 56 52 50 46 44 40 30 50 30 77 77 69 68 61 59 54 51 48 45 43 40 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 240 75° 480 60° 720 960 45° 1200 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 30.6 17.2 11 7.7 5.6 4.3 3.4 2.8 0.4’ 0.5’ 0.6’ 0.7’ 0.8’ 1’ 1.1’ 1.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° 80 50 30 86 86 74 71 64 59 55 51 48 44 43 38 50 50 30 80 80 70 68 61 58 53 50 47 43 42 38 30 50 30 74 74 66 65 58 56 51 48 46 42 41 37 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 300 75° 600 60° 900 1200 45° 1500 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 40 22.5 14.4 10 7.3 5.6 4.4 3.6 0.4’ 0.5’ 0.6’ 0.7’ 0.8’ 1’ 1.1’ 1.2’ Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 73% Spacing Criteria 0.6 Certificate S0611281R1 Matte Reflector 0.82 Multiplier 80 50 30 87 87 74 70 62 58 54 49 47 42 41 36 50 50 30 81 81 70 67 60 56 52 48 45 41 40 36 30 50 30 74 74 66 64 57 54 50 47 44 40 39 35 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 507 FLUO 6” FR6VO Downlight FR6VO-11 1 x TTT Narrow Flood Vertical Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-08 Housings Specifications Max 9” 229mm New Construction (NW) Code Lamp NWF6VU42 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” X H 10” X 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base Volts Ballast L GX/G24q-3/q-4 (4 pin) 120-277V Electronic 143/16” W X H 8” X 93/16” ø 8” 203mm Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VO-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-02MG 508 www.contrastlighting.com FR6VO 1 x TTT Narrow Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 300 75° 600 60° 900 1200 45° 1500 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 39.5 22.2 14.2 9.9 7.3 5.6 4.4 3.6 0.5’ 0.6’ 0.8’ 0.9’ 1.1’ 1.2’ 1.4’ 1.6’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILIZATION - % LUMINAIRE Lamp Type Initial Lumens 26W Triple Tube, 4pin Ceiling Reflect % 80 50 30 Wall Reflect % 50 30 50 30 50 30 1800 120V 277V 347V RCR 0 85 85 80 80 73 73 Input Watts 28W 28W 31W 2 73 70 70 68 66 64 Operating AMPS 0.25A 0.11A 0.09A 4 63 59 61 58 58 56 Luminaire Efficiency 71% 6 55 51 53 50 52 49 8 48 44 47 43 46 43 Spacing Criteria 0.8 10 43 39 42 38 41 38 Certificate S0611293R1 Matte Reflector Zonal Cavity Method Effective Floor 0.82 Multiplier Cavity Reflectance 20% 1 X 32W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 300 75° 720 60° 1080 1440 45° 1800 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 47.7 26.8 17.2 11.9 8.8 6.7 5.3 4.3 0.6’ 0.8’ 1’ 1.2’ 1.3’ 1.5’ 1.7’ 1.9’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILIZATION - % LUMINAIRE 50 30 32W Triple Tube, 4pin Ceiling Reflect % 80 Wall Reflect % 50 30 50 30 50 30 2400 0 93 93 86 86 79 79 120V 277V 347V RCR Input Watts 36W 36W 36W 2 78 75 74 72 70 68 Operating AMPS 0.30A 0.13A 0.11A 4 66 61 64 60 60 57 6 57 51 55 50 52 49 Luminaire Efficiency 78% 8 49 44 48 43 46 42 Spacing Criteria 0.8 10 43 38 42 37 41 37 Certificate S0611303R1 Matte Reflector Zonal Cavity Method Effective Floor 0.82 Multiplier Cavity Reflectance 20% Lamp Type Initial Lumens 1 X 42W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 460 75° 920 60° 1380 1840 45° 2300 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 61.8 34.7 22.2 15.4 11.3 8.7 6.9 5.6 0.5’ 0.6’ 0.8’ 0.9’ 1.1’ 1.2’ 1.4’ 1.6’ Beam Edge defined as 50% of Maximum Nadir Candlepower COEFFICIENT OF UTILIZATION - % LUMINAIRE 50 30 42W Triple Tube, 4pin Ceiling Reflect % 80 Wall Reflect % 50 30 50 30 50 30 3200 120V 277V 347V RCR 0 87 87 81 81 74 74 Input Watts 48W 48W 50W 2 73 70 69 67 65 63 Operating AMPS 0.41A 0.18A 0.15A 4 53 48 51 47 49 46 Luminaire Efficiency 72% 6 53 48 51 47 49 46 8 46 41 44 40 43 39 Spacing Criteria 0.7 10 40 35 39 35 38 35 Certificate S0612041R1 Matte Reflector Zonal Cavity Method Effective Floor 0.82 Multiplier Cavity Reflectance 20% Lamp Type Initial Lumens Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 509 FLUO 6” FR6VO Open FR6VO-11 1 x DTT Wide Flood Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-06 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts (4 pin) 120-277V (4 pin) 120-277V (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VO-13 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-14MG 510 www.contrastlighting.com FR6VO 1 x DTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 140 75° 280 60° 420 560 45° 700 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 19.1 10.8 6.9 4.8 3.5 2.7 2.1 1.7 0.5’ 0.6’ 0.8’ 0.9’ 1.1’ 1.2’ 1.4’ 1.6’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens 13W Quad Tube, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 82% Spacing Criteria 0.6 Certificate S0611241R1 Matte Reflector 0.82 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens 18W Quad Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 81% Spacing Criteria 0.6 Certificate S0611273R1 Matte Reflector 0.82 Multiplier Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 98 98 82 78 68 63 58 52 50 44 43 38 50 50 30 91 91 78 75 65 61 56 51 48 43 42 37 30 50 30 84 84 73 71 62 59 53 50 46 42 41 37 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 160 75° 320 60° 480 640 45° 800 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 22.1 12.5 8 5.5 4.1 3.1 2.5 2 0.5’ 0.6’ 0.8’ 0.9’ 1.1’ 1.2’ 1.4’ 1.6’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° 80 50 30 97 97 80 75 65 59 54 48 46 40 40 34 50 50 30 91 91 75 72 62 58 52 47 45 39 39 34 30 50 30 83 83 71 68 59 55 50 46 43 39 37 33 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 240 75° 480 60° 720 960 45° 1200 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 17.6 9.9 6.3 4.4 3.2 2.5 2 1.6 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 26W Quad Tube, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 80% Spacing Criteria 0.6 Certificate S0611284R1 Matte Reflector 0.82 Multiplier 80 50 30 96 96 77 73 63 57 52 46 44 38 38 33 50 50 30 90 90 73 70 60 55 50 45 43 37 37 32 30 50 30 82 82 68 66 56 53 48 43 41 37 36 31 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 511 FLUO 6” FR6VO Downlight FR6VO-11 1 x TTT Wide Flood Vertical Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-05 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” X H 10” X 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts Ballast L W H (4 pin) 120-277V Electronic 143/16” X 8” X 93/16” ø 8” 203mm Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VO-01 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-05MG 512 www.contrastlighting.com FR6VO 1 x TTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOM Efficient CFL Housings Socket & Lamp Bases High temperature-rated 130˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 240 75° 480 60° 720 960 45° 1200 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 31.2 17.6 11.2 7.8 5.7 4.4 3.5 2.8 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILISATION - % LUMINAIRE Lamp Type Initial Lumens 26W Triple Tube, 4pin Ceiling Reflect % 80 50 30 Wall Reflect % 50 30 50 30 50 30 1800 120V 277V 347V RCR 0 91 91 85 85 78 78 Input Watts 28W 28W 31W 2 76 73 72 70 68 66 Operating AMPS 0.25A 0.11A 0.09A 4 64 59 62 58 58 56 Luminaire Efficiency 76% 6 54 49 53 48 50 47 8 47 42 45 41 44 40 Spacing Criteria 0.9 10 41 36 40 35 38 35 Certificat S0611296R1 Matte Reflector Zonal Cavity Method Effective Floor 0.82 Multiplier Cavity Reflectance 20% 1 X 32W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 300 75° 600 60° 900 1200 45° 1500 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 39.2 12.5 8 5.5 4.1 3.1 2.5 2 0.8’ 1.1’ 1.4’ 1.7’ 2’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILISATION - % LUMINAIRE 50 30 32W Triple Tube, 4pin Ceiling Reflect % 80 Wall Reflect % 50 30 50 30 50 30 2400 0 106 106 99 99 91 91 120V 277V 347V RCR Input Watts 36W 36W 36W 2 87 82 82 78 77 74 Operating AMPS 0.30A 0.13A 0.11A 4 71 64 67 62 64 60 6 59 52 56 51 54 49 Luminaire Efficiency 89% 8 50 43 48 42 46 41 Spacing Criteria 0.9 10 43 36 42 36 40 35 Certificat S0612013R1 Matte Reflector Zonal Cavity Method Effective Floor 0.82 Multiplier Cavity Reflectance 20% Lamp Type Initial Lumens 1 X 42W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 360 75° 720 60° 1080 1440 45° 1800 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 49.5 27.8 17.5 12.4 9.1 7 5.5 4.5 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILISATION - % Lamp Type Initial Lumens Ceiling Reflect % 80 Wall Reflect % 50 30 RCR 0 102 102 2 82 77 4 66 60 6 55 48 8 47 40 42W Triple Tube, 4pin 3200 120V 277V 347V Input Watts 48W 48W 50W Operating AMPS 0.41A 0.18A 0.15A Luminaire Efficiency 85% Spacing Criteria 0.8 Certificat S0612044R1 Matte Reflector 0.82 Multiplier 50 50 30 95 95 78 74 63 58 53 47 45 39 30 50 30 88 88 72 70 60 56 50 46 43 38 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 513 4” 6 FLUO FR6VOG-O4FUR05 FR6VOG-O4RFF07 FR6VOG-O4BRIND03 FR6VOG Downlight Vertical FR6VOG-O4WFF00 Damp location Compact fluorescent: 1 X 13W DTT 1 X 18W DTT 1 X 26W DTT Reflector 93/16” 233mm Standard: semi-specular low iridescence aluminum 3/16” 5mm Housings Specifications 3” 76mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W Base G24q-1 G24q-2 G24q-3 DTT DTT DTT Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 5” 127mm 93/16” 93/16” 93/16” 7” 178mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W Base G24q-1 G24q-2 G24q-3 DTT DTT DTT Volts Ballast L W H (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” X X X ø 6 3/16” 157mm 93/16” 93/16” 93/16” Ø 8” 203mm Hole Cut : 63/4” Glass Colors FUR IND Furia SUN India A M Sunset Amber R Eggplant B Red Clobalt Blue W CAR White Caramel Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOG-05SUNC05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOG-01MGFUR03 514 www.contrastlighting.com FR6VOG Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S FR6VOG Trim codification MODEL FR6VOG Listings • cULus Listed for through branch wiring and damp location. 6” Specs and codification FR6VOG-04BRWFFOO TRIM FINISH GLASS COLOR GLASS TEXTURE GLASS LENGTH -04BR W FF 00 -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C FLUO • 277V: For dimming capability, change «U» Locking System to «D» and add «2» at the end of the housing • Perfect fit to ceiling code of 18W to 42W. Ex: NWF6VD26S2 • No light leak • Hooks PAT #CAN. 2.088.648 Mounting Bars and #USA. 5.377.088 • For NW. • Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings • Lockable integral T-Bar tabs. May be hung Reflector from trusses or suspended ceilings. 0.04’’aluminium reflector with low iridescence semi specular Housing Features clear finish. • Galvanized steel • Below ceiling accessible Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty FUR IND CAR B M R A W SUN Furia India Caramel Cobalt Blue Amber Red Eggplant White Sunset EXCEPTION : There is no texture to specify for Furia and India glass. FF Frosted int./ext. C Clear 00 03 05 07 Flush (0”) 3” of the trim 5” of the trim 7” of the trim 515 FLUO 6” FR6VOLA 1 x DTT Wide Flood Vertical FR6VOLA-01 Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 13/16” 30mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W H (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” X X X 93/16” 93/16” 93/16” ø 8” 203mm Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOLA-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLA-11MG 516 www.contrastlighting.com FR6VOLA 1 x DTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 55 75° 110 60° 165 220 45° 275 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 7.3 4.1 2.6 1.8 1.3 1 0.8 0.7 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad Tube, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 62% Spacing Criteria 1 Certificate S0611242R1 80 50 30 73 73 57 53 45 40 37 32 31 26 26 22 50 50 30 67 67 53 50 42 38 35 30 29 25 25 21 30 50 30 61 61 48 46 39 36 32 29 27 24 24 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 65 75° 130 60° 200 265 45° 330 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 9 5 3.2 2.2 1.6 1.2 1 0.8 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 61% Spacing Criteria 1 Certificate S0611274R1 80 50 30 72 72 56 52 44 39 36 30 29 24 24 20 50 50 30 66 66 52 49 41 37 34 29 28 24 24 20 30 50 30 60 60 47 45 38 35 31 28 26 23 23 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 90 75° 180 60° 270 360 45° 450 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 12.4 7 4.5 3.1 2.3 1.8 1.4 1.1 0.8’ 1.1’ 1.4’ 1.7’ 2’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad Tube, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 59% Spacing Criteria 1 Certificate S0611285R1 80 50 30 70 70 54 50 42 37 34 29 29 24 24 20 50 50 30 65 65 50 47 40 36 32 28 27 23 23 19 30 50 30 58 58 45 43 36 33 30 27 43 38 22 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 517 FLUO 6” FR6VOLA 1 x TTT Wide Flood Vertical FR6VOLA-01 Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications Max 9” 229mm New Construction (NW) Code Lamp NWF6VU42 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” X H 10” X 93/16” X 93/16” Hole Cut : 63/4” 13/16” 30mm Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts Ballast L W H (4 pin) 120-277V Electronic 143/16” X 8” Hole Cut : 63/4” ø 8” 203mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOLA-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLA-11MG 518 www.contrastlighting.com FR6VOLA 1 x TTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 100 75° 200 60° 300 400 45° 500 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 13.3 7.5 4.8 3.3 2.4 1.9 1.5 1.2 0.8’ 1.1’ 1.4’ 1.7’ 2’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILISATION - % Lamp Type Initial Lumens 80 50 30 67 67 52 49 41 37 34 29 28 24 24 20 26W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 1800 120V 277V 347V RCR 0 Input Watts 28W 28W 31W 2 Operating AMPS 0.25A 0.11A 0.09A 4 Luminaire Efficiency 56% 6 8 Spacing Criteria 1 10 Certificat S0611301R1 50 50 30 61 61 48 46 39 35 32 28 27 23 23 20 30 50 30 55 55 44 42 36 33 30 27 25 22 22 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 32W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 135 75° 270 60° 405 540 45° 675 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 18.5 10.4 6.7 4.6 3.4 2.6 2.1 1.7 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILISATION - % LUMINAIRE 32W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 2400 0 120V 277V 347V RCR Input Watts 36W 36W 36W 2 Operating AMPS 0.30A 0.13A 0.11A 4 6 Luminaire Efficiency 66% 8 Spacing Criteria 1.1 10 Certificat S06112014R1 Lamp Type Initial Lumens 80 50 30 78 78 60 56 47 42 38 33 32 27 27 22 50 50 30 72 72 56 53 44 40 36 31 30 26 26 22 30 50 30 65 65 51 49 41 37 33 30 28 25 24 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 42W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 165 75° 330 60° 500 665 45° 830 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 18.5 10.4 6.7 4.6 3.4 2.6 2.1 1.7 1’ 1.3’ 1.7’ 2’ 2.3’ 2.7’ 3’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower COEFFICIENT OF UTILISATION - % LUMINAIRE 42W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 3200 120V 277V 347V RCR 0 Input Watts 48W 48W 50W 2 Operating AMPS 0.41A 0.18A 0.15A 4 Luminaire Efficiency 63% 6 8 Spacing Criteria 1 10 Certificat S0612045R1 Lamp Type Initial Lumens 80 50 30 75 75 58 53 45 40 37 31 30 25 26 21 50 50 30 69 69 53 50 42 38 34 30 29 24 25 20 30 50 30 62 62 48 46 38 35 32 28 27 23 23 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 519 FLUO 6” FR6VOLB 1 x DTT Wide Flood Vertical FR6VOLB-01 Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector FLUO Standard: semi-specular low iridescence aluminum Housings Specifications New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast Max 9” 229mm L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 13/16” 30mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W H (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” (4 pin) 120-277V Electronic 143/16” X 8” X X X 93/16” 93/16” 93/16” ø 8” 203mm Hole Cut : 63/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOLB-02 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLB-02MG 520 www.contrastlighting.com FR6VOLB 1 x DTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 80 75° 160 60° 240 320 45° 400 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 10.9 6.1 3.9 2.7 2 1.5 1.2 1 0.6’ 0.8’ 1’ 1.2’ 1.3’ 1.5’ 1.7’ 1.9’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad Tube, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 67% Spacing Criteria 1 Certificate S0611243R1 80 50 30 80 80 64 60 52 46 43 37 36 31 31 26 50 50 30 74 74 60 57 49 44 41 36 35 30 30 26 30 50 30 67 67 55 53 45 42 38 35 33 29 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 18W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 95 75° 190 60° 285 380 45° 475 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 13 7.3 4.7 3.2 2.4 1.8 1.4 1.2 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad Tube, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 66% Spacing Criteria 0.8 Certificate S0611275R1 80 50 30 78 78 62 58 50 44 41 35 34 29 30 25 50 50 30 72 72 58 54 46 42 39 34 33 28 28 24 30 50 30 65 65 53 51 43 40 36 33 31 27 27 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 26W Elect. DTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 120 75° 240 60° 260 480 45° 600 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 17.6 9.9 6.3 4.4 3.2 2.5 2 1.6 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad Tube, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 64% Spacing Criteria 0.8 Certificate S0611291R1 80 50 30 76 76 59 55 47 42 39 34 33 28 28 24 50 50 30 70 70 55 52 44 40 37 32 31 27 27 23 30 50 30 63 63 50 48 41 38 34 31 29 26 26 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 521 FLUO 6” FR6VOLB 1 x TTT Wide Flood Vertical FR6VOLB-01 Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications Max 9” 229mm New Construction (NW) Code Lamp NWF6VU42 1 X 26/32/42W TTT Base GX24q-3/q-4 (4 pin) Volts Ballast L 120-277V Electronic 191/8” W X H 10” X 93/16” X 93/16” Hole Cut : 63/4” 13/16” 30mm Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 (4 pin) Volts Ballast L 120-277V Electronic 143/16” W X H 8” Hole Cut : 63/4” ø 8” 203mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOLB-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLB-14MG 522 www.contrastlighting.com FR6VOLB 1 x TTT Wide Flood Vertical Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF6VD26S • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION CONE OF LIGHT Candelas 90° Distance FC DIA 140 75° 280 60° 420 560 45° 700 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 19.4 10.9 7 4.8 3.6 2.7 2.2 1.7 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens 80 50 30 73 73 58 55 47 43 39 34 33 29 29 24 26W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 1800 120V 277V 347V RCR 0 Input Watts 28W 28W 31W 2 Operating AMPS 0.25A 0.11A 0.09A 4 Luminaire Efficiency 61% 6 8 Spacing Criteria 0.9 10 Certificate S0611302R1 50 50 30 67 67 54 52 45 41 37 33 32 28 28 24 30 50 30 61 61 50 48 41 39 35 32 30 27 26 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 32W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 185 75° 370 60° 555 740 45° 925 0° 15° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 25.1 14.1 9 6.3 4.6 3.5 2.8 2.3 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° COEFFICIENT OF UTILIZATION - % LUMINAIRE 32W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 2400 0 120V 277V 347V RCR Input Watts 36W 36W 36W 2 Operating AMPS 0.30A 0.13A 0.11A 4 6 Luminaire Efficiency 70% 8 Spacing Criteria 0.6 10 Certificate S0612015R1 Lamp Type Initial Lumens 80 50 30 84 84 66 61 52 47 43 37 36 31 31 26 50 50 30 77 77 61 58 49 45 41 36 35 30 30 25 30 50 30 69 69 56 54 45 42 38 34 32 29 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 1 X 42W Elect. TTT CONE OF LIGHT CANDLEPOWER DISTRIBUTION Candelas 90° Distance FC DIA 240 75° 480 60° 720 960 45° 1200 0° 15° 30° 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ 31.4 17.7 11.3 7.9 5.8 4.4 3.5 2.8 0.7’ 0.9’ 1.2’ 1.4’ 1.6’ 1.9’ 2.1’ 2.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower COEFFICIENT OF UTILIZATION - % LUMINAIRE 42W Triple Tube, 4pin Ceiling Reflect % Wall Reflect % 3200 120V 277V 347V RCR 0 Input Watts 48W 48W 50W 2 Operating AMPS 0.41A 0.18A 0.15A 4 Luminaire Efficiency 68% 6 8 Spacing Criteria 0.4 10 Certificate S0612046R1 Lamp Type Initial Lumens 80 50 30 80 80 63 58 50 44 41 35 34 29 30 24 50 50 30 74 74 58 55 47 42 39 34 33 28 28 24 30 50 30 66 66 53 51 43 40 36 32 31 27 27 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% Instructions for Lamp Position DIAGRAM FOR NARROW/WIDE FLOOD ADJUSTMENT FOR NARROW FLOOD (N) 26W DTT 42W TTT FOR WIDE FLOOD (W) N N N 18W DTT 13W DTT 26W TTT 32W TTT W W 26W DTT 42W TTT 13W 18W 26W 32W DTT DTT TTT TTT REFLECTOR 523 FLUO 6” FR6VOW90 90° Wall Wash FR6VOW90-01 1 x DTT Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90M-05 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts (4 pin) 120-277V (4 pin) 120-277V (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW90-05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90-02MG 524 www.contrastlighting.com FR6VOW90 1 x DTT Vertical Technical Specifications Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOMW90 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 95 75° 75° 195 60° 60° 290 45° 45° 385 30° 90° 15° 480 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 77% Spacing Criteria 0.6 (0-180) 0.8 (90-270) Certificate S0806051R1 30° 80 50 30 92 92 75 71 61 55 51 45 43 37 37 31 50 50 30 85 85 71 68 58 54 49 44 41 36 36 31 10 50 30 78 78 66 64 55 52 46 42 39 35 34 30 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 110 75° 75° 220 60° 60° 330 45° 90° 45° 440 30° 15° 550 0° 0° 15° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 70% Spacing Criteria 1.0 (0-180) 0.9 (90-270) Certificate 30° S0806061R1 80 50 30 83 83 66 62 53 48 44 38 37 31 31 26 50 50 30 78 78 63 59 50 46 42 37 35 30 30 26 10 50 30 71 71 58 56 47 44 40 36 34 30 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 155 75° 75° 315 60° 60° 470 45° 90° 45° 625 30° 15° 780 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 82% Spacing Criteria 0.5 (0-180) 1.1 (90-270) Certificate S0804072R1 80 50 30 97 97 76 71 60 53 49 42 41 34 35 29 50 50 30 91 91 71 67 57 52 47 41 39 34 34 28 10 50 30 83 83 66 64 53 49 44 40 38 33 32 28 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 525 FLUO 6” FR6VOW90 90° Wall Wash FR6VOW90-01 1 x TTT Vertical Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90M-05 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W DTT 1 X 18W DTT 1 X 26/32/42W TTT Base G24q-1 G24q-2 GX24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W DTT 1 X 18W DTT 1 X 26/32/42W TTT Base G24q-1 G24q-2 GX24q-3/q-4 Volts (4 pin) 120-277V (4 pin) 120-277V (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW90-05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code.Ex.: F6VOW90-02MG 526 www.contrastlighting.com FR6VOW90 1 x TTT Vertical Technical Specifications Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOMW90 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 165 75° 75° 330 60° 60° 500 45° 30° 90° 45° 665 15° 830 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 66% Spacing Criteria 1.1 (0-180) 1.1 (90-270) Certificate S0806101R1 80 50 30 78 78 64 61 53 48 44 39 37 33 32 28 50 50 30 73 73 61 58 51 47 42 38 36 32 31 27 10 50 30 67 67 57 55 48 45 40 37 35 31 30 27 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 200 75° 75° 395 60° 60° 595 45° 30° 90° 45° 790 15° 990 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 69% Spacing Criteria 1.1 (0-180) 1.1 (90-270) Certificate S0806111R1 80 50 30 82 82 66 62 53 48 44 38 37 31 31 26 50 50 30 77 77 62 59 51 46 42 37 35 31 30 26 10 50 30 71 71 58 56 48 44 40 36 34 30 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 300 75° 75° 600 60° 60° 900 45° 90° 45° 1200 30° 15° 1500 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 42W Triple Tube, 4pin 3200 120V 277V 347V Input Watts 48W 48W 50W Operating AMPS 0.41A 0.18A 0.15A Luminaire Efficiency 64% Spacing Criteria 1.0 (0-180) 1.0 (90-270) Certificate S0806117R1 80 50 30 77 77 62 58 50 46 42 37 35 31 31 26 50 50 30 72 72 59 56 48 44 40 36 34 30 30 26 10 50 30 66 66 55 53 45 42 38 35 33 29 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 527 FLUO 6” FR6VOW90D 90° Doube Wall Wash FR6VOW90D-01 1 x DTT Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90DM-05 Housings Specifications Max 9” 229mm New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 Volts Ballast L W (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” (4 pin) 120-277V Electronic 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base Volts (4 pin) 120-277V G24q-1 (4 pin) 120-277V G24q-2 GX/G24q-3/q-4 (4 pin) 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW90D-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90D-01MG 528 www.contrastlighting.com FR6VOW90D 1 x DTT Vertical Technical Specifications Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOMW90D Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 60 75° 75° 125 60° 60° 185 45° 30° 90° 45° 250 15° 310 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 68% Spacing Criteria 0.7 (0-180) 1.2 (90-270) Certificate S0806121R1 80 50 30 81 81 64 60 51 46 42 36 35 29 30 25 50 50 30 75 75 60 57 49 44 40 35 34 29 29 24 10 50 30 69 69 56 54 46 42 38 34 32 28 27 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 80 75° 75° 160 60° 60° 240 45° 90° 45° 320 30° 15° 400 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 71% Spacing Criteria 0.6 (0-180) 1.3 (90-270) Certificate S0806124R1 80 50 30 84 84 66 61 52 46 42 36 35 29 30 24 50 50 30 78 78 62 58 49 44 40 35 33 28 29 24 10 50 30 72 72 58 55 46 42 38 34 32 28 27 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 110 75° 75° 220 60° 60° 325 45° 90° 45° 430 30° 15° 540 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 76% Spacing Criteria 1.2 (0-180) 1.4 (90-270) Certificate S0804073R1 80 50 30 91 91 70 65 54 48 44 37 36 30 31 25 50 50 30 85 85 65 62 51 46 42 36 35 29 29 24 10 50 30 78 78 61 58 48 44 39 35 33 28 28 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 529 FLUO 6” FR6VOW90D 90° Doube Wall Wash FR6VOW90D-01 1 x TTT Vertical Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90DM-05 Housings Specifications Max 9” 229mm New Construction (NW) Code Lamp NWF6VU42 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts (4 pin) 120-277V Ballast L Electronic 191/8” W X H 10” X 93/16” X 93/16” Hole Cut : 63/4” 3/16” 5mm Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 Volts (4 pin) 120-277V Ballast L Electronic 143/16” W X H 8” ø 8” 203mm Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW90D-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90D-01MG 530 www.contrastlighting.com Technical Specifications Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 1 x TTT Vertical • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOMW90d Trims Plated or painted steel 6” Efficient CFL Housings Socket & Lamp Bases High temperature-rated 130˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM#283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty FR6VOW90D Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 120 75° 75° 230 60° 60° 350 45° 30° 90° 45° 460 15° 580 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 68% Spacing Criteria 1.2 (0-180) 1.4 (90-270) Certificate S0806125R1 80 50 30 81 81 65 61 52 47 43 37 36 30 30 25 50 50 30 76 76 61 58 49 45 41 36 34 30 29 25 10 50 30 69 69 57 55 47 43 39 35 33 29 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 160 75° 75° 320 60° 60° 475 45° 90° 45° 630 30° 15° 790 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 77% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0806128R1 80 50 30 91 91 71 67 56 50 46 39 38 32 32 26 50 50 30 85 85 67 64 54 48 44 38 36 31 31 26 10 50 30 78 78 63 60 50 46 41 37 35 30 30 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 140 75° 75° 285 60° 60° 425 45° 90° 45° 570 30° 15° 710 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 42W Triple Tube, 4pin 3200 120V 277V 347V Input Watts 48W 48W 50W Operating AMPS 0.41A 0.18A 0.15A Luminaire Efficiency 62% Spacing Criteria 1.4 (0-180) 1.4 (90-270) Certificate S08061211R1 80 50 30 73 73 56 52 44 38 35 30 29 24 24 20 50 50 30 69 69 53 50 41 37 33 29 28 23 24 19 10 50 30 63 63 49 47 39 35 31 28 26 22 22 19 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 531 FLUO 6” FR6VOW120 120° Wall Wash FR6VOW120-01 1 x DTT Vertical Damp location Compact fluorescent: 1 X CFQ-13W 1 X CFQ-18W 1 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW120M-05 Max 9” 229mm Housings Specifications New Construction (NW) Code NWF6VU13 NWF6VU18 NWF6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 93/16” 93/16” 93/16” 3/16” 5mm Hole Cut : 63/4” Remodel Code F6VU13 F6VU18 F6VU42 Lamp 1 X 13W 1 X 18W 1 X 26W DTT DTT DTT Base G24q-1 G24q-2 G24q-3/q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 143/16” 143/16” 143/16” X X X ø 8” 203mm H 8” 8” 8” X X X 93/16” 93/16” 93/16” Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW120-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW120-05MG 532 www.contrastlighting.com FR6VOW120 1 x DTT Vertical Technical Specifications Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR6VOMW120 Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 90 75° 75° 185 60° 60° 275 45° 30° 90° 45° 370 15° 460 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 13W Quad, 4pin 900 120V 277V 347V Input Watts 18W 18W 18W Operating AMPS 0.15A 0.07A 0.06A Luminaire Efficiency 71% Spacing Criteria 1.2 (0-180) 1.1 (90-270) Certificate S0806052R1 80 50 30 84 84 68 65 56 50 46 40 39 33 33 28 50 50 30 78 78 65 62 53 49 44 40 37 33 32 28 10 50 30 72 72 60 58 50 47 42 38 36 32 31 27 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 105 75° 75° 210 60° 60° 315 45° 30° 90° 45° 415 15° 520 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 18W Quad, 4pin 1200 120V 277V 347V Input Watts 19W 19W 21W Operating AMPS 0.16A 0.07A 0.06A Luminaire Efficiency 71% Spacing Criteria 1.1 (0-180) 1.0 (90-270) Certificate S0806062R1 80 50 30 84 84 67 62 53 47 43 38 36 31 31 26 50 50 30 79 79 63 60 51 46 42 37 35 30 30 25 10 50 30 72 72 59 56 47 44 39 35 33 29 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 150 75° 75° 300 60° 60° 445 45° 90° 45° 595 30° 15° 740 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Quad, 4pin 1710 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 75% Spacing Criteria 0.5 (0-180) 1.1 (90-270) Certificate S0804071R1 80 50 30 90 90 69 64 55 48 44 38 37 31 31 26 50 50 30 84 84 65 62 52 47 42 37 35 30 30 25 10 50 30 77 77 61 58 48 45 40 36 34 29 29 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 533 FLUO 6” FR6VOW120 120° Wall Wash FR6VOW120-01 1 x TTT Vertical Damp location Compact fluorescent: 1 X CFTR-26W 1 X CFTR-32W 1 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW120M-05 Max 9” 229mm Housings Specifications New Construction (NW) Code Lamp NWF6VU42 1 X 26/32/42W TTT Base GX24q-3/q-4 (4 pin) Volts Ballast 120-277V Electronic L W 191/8” X H 10” X 93/16” Hole Cut : 63/4” 3/16” 5mm Remodel Code F6VU42 Lamp 1 X 26/32/42W TTT Base GX24q-3/q-4 (4 pin) Volts Ballast 120-277V Electronic L W 143/16” X H 8” X 93/16” ø 8” 203mm Hole Cut : 63/4” 61/2” 166mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR6VOW120-03 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW120-05MG 534 www.contrastlighting.com FR6VOW120 1 x TTT Vertical Technical Specifications Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Locking System Ex.: NWF6VD26S • Perfect fit to ceiling • 277V: For dimming capability, change «U» • No light leak to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF6VD26S2 • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: F6VU42M Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 6” FLUO Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 1 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 155 75° 75° 315 60° 60° 470 45° 30° 90° 45° 625 15° 780 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 26W Triple Tube, 4pin 1800 120V 277V 347V Input Watts 28W 28W 31W Operating AMPS 0.25A 0.11A 0.09A Luminaire Efficiency 65% Spacing Criteria 1.2 (0-180) 1.2 (90-270) Certificate S0806102R1 80 50 30 77 77 63 60 52 47 43 38 36 31 31 26 50 50 30 72 72 60 57 49 45 41 37 35 31 30 26 10 50 30 66 66 56 54 47 44 39 36 33 30 29 26 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 200 75° 75° 395 60° 60° 595 45° 30° 90° 45° 795 15° 990 0° 0° 15° 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 32W Triple Tube, 4pin 2400 120V 277V 347V Input Watts 36W 36W 36W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 73% Spacing Criteria 1.2 (0-180) 1.2 (90-270) Certificate S0806112R1 80 50 30 87 87 69 65 55 50 45 39 38 32 32 27 50 50 30 81 81 65 62 53 48 43 38 36 31 31 26 10 50 30 75 75 61 59 49 46 41 37 35 31 30 26 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0° 1 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 90° 280 75° 75° 560 60° 60° 840 45° 90° 45° 1120 30° 15° 1400 0° 0° 15° 30° 0° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 42W Triple Tube, 4pin 3200 120V 277V 347V Input Watts 48W 48W 50W Operating AMPS 0.41A 0.18A 0.15A Luminaire Efficiency 64% Spacing Criteria 1.1 (0-180) 1.0 (90-270) Certificate S0806118R1 80 50 30 76 76 61 57 49 44 41 36 34 29 30 25 50 50 30 71 71 58 55 47 43 39 35 33 29 29 25 10 50 30 65 65 54 52 44 41 37 34 32 28 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 535 Compact Fluorescent Energy Efficient Lighting 7” FLUO 7” FR7C Cross Louver FR7C-11 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications New Construction (NW) Code NWF7U13 NWF7U18 NWF7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X 63/16” 157mm H 10” 10” 10” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 8” Remodel Code F7U13 F7U18 F7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 G24q-2 G24q-3 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 91/16” X 63/16” 145/8” 145/8” X 91/16” 91/16” X 63/16” 63/16” X ø 91/8” 232mm H 145/8” X Hole Cut : 8” 75/8” 194mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR7C-05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR7C-05MG 538 www.contrastlighting.com FR7C 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF7D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF7D262 Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 7” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF7U26EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 125 75° 255 60° 385 510 45° 640 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 13.4 7.5 4.8 3.4 2.5 1.9 1.5 1.2 LUMINAIRE DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate COEFFICIENT OF UTILIZATION - % Two 13W Quad, 4pin 1800 120V 277V 347V 30W 30W 33W 0.26A 0.11A 0.10A 51.9% 1.4 (0-180) 1.6 (90-270) S0602163 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 62 62 51 49 43 39 36 32 30 26 26 22 50 50 30 58 58 49 47 41 38 34 31 29 26 25 22 30 50 30 55 55 47 46 40 37 33 31 28 25 24 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 135 75° 270 60° 405 540 45° 675 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 15.8 8.9 5.7 3.9 2.9 2.2 1.8 1.4 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 18W Quad, 4pin 2500 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 51.7% Spacing Criteria 1.4 (0-180) 1.6 (90-270) Certificate S0601183 80 50 30 62 62 51 48 42 38 35 31 29 26 25 21 50 50 30 58 58 48 46 40 37 34 30 28 25 24 21 30 50 30 55 55 47 45 39 36 33 30 28 25 24 21 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 200 75° 400 60° 600 800 45° 1000 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 24.3 13.7 8.8 6.1 4.5 3.4 2.7 2.2 LUMINAIRE DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate COEFFICIENT OF UTILIZATION - % Two 26W Quad, 4pin 3600 120V 277V 347V 56W 56W 57W 0.47A 0.21A 0.17A 64.5% 1.4 (0-180) 1.9 (90-270) S0602152 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 77 77 62 59 50 45 41 36 34 29 29 24 50 50 30 72 72 59 56 48 44 39 35 33 28 28 23 30 50 30 69 69 57 55 46 43 38 34 32 28 27 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 539 FLUO 7” FR7O Downlight FR7O-11 2 x DTT/TTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** 2 X CFTR-26W Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR7OM-04 Housings Specifications New Construction (NW) Code NWF7U13 NWF7U18 NWF7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT/TTT Base (4 pin) G24q-1 (4 pin) G24q-2 GX/G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X 63/16” 157mm H 10” 10” 10” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 8” Remodel Code F7U13 F7U18 F7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT/TTT Base (4 pin) G24q-1 (4 pin) G24q-2 GX/G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 91/16” X 63/16” 145/8” 145/8” X 91/16” 91/16” X 63/16” 63/16” X ø 91/8” 232mm H 145/8” X Hole Cut : 8” 7” 178mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR7O-06 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR7O-11MG 540 www.contrastlighting.com FR7O 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F7D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F7D182 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to trim code. Ex: FR70M Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 7” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF7U13EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 130 75° 265 60° 400 525 45° 660 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 13.6 7.7 4.9 3.4 2.5 1.9 1.5 1.2 LUMINAIRE DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate Matte Reflector Multiplier CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Two 13W Quad, 4pin 1800 120V 277V 347V 30W 30W 33W 0.26A 0.11A 0.10A 64% 1.3 (0-180) 2.0 (90-270) S0602162 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 76 76 62 59 50 45 41 36 34 29 29 24 50 50 30 71 71 59 56 48 44 39 35 33 28 28 23 0.95 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 30 50 30 68 68 57 55 46 43 38 34 32 28 27 23 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 165 75° 330 60° 500 665 45° 830 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 19.7 11.1 7.1 4.9 3.6 2.8 2.2 1.8 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate Matte Reflector Multiplier CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Two 18W Quad, 4pin 2500 120V 277V 347V 35W 35W 38W 0.30A 0.13A 0.11A 79.9% 1.7 (0-180) 2.0 (90-270) S0601182 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 95 95 77 72 62 55 50 43 41 35 34 18 50 50 30 89 89 73 69 59 54 48 42 39 34 33 28 0.95 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 30 50 30 85 85 70 67 57 53 46 42 38 33 32 27 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 190 75° 380 60° 570 760 45° 950 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 22.1 12.5 8.0 5.5 4.1 3.1 2.5 2.0 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Lamp Type Initial Lumens Beam Edge defined as 50% of Maximum Nadir Candlepower Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate Matte Reflector Multiplier CONE OF LIGHT LUMINAIRE COEFFICIENT OF UTILIZATION - % Two 26W Quad, 4pin 3420 120V 277V 347V 56W 56W 57W 0.47A 0.21A 0.17A 51.1% 1.3 (0-180) 1.5 (90-270) S0602151 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 61 61 51 48 42 38 35 31 30 26 25 22 50 50 30 57 57 48 46 40 37 34 31 29 26 25 22 0.95 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 30 50 30 54 54 46 45 39 37 33 30 28 25 24 21 2 X 26W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 280 75° 560 60° 840 1120 45° 1400 0° 15° 30° Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 34.8 19.6 12.5 8.7 6.4 4.9 3.9 3.1 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificate Matte Reflector Multiplier COEFFICIENT OF UTILIZATION - % Two 26W Triple, 4pin 3600 120V 277V 347V 56W 56W 57W 0.47A 0.21A 0.17A 65.5% 1.2 (0-180) 1.9 (90-270) S0704092R1 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 78 78 64 60 52 47 43 38 36 31 30 25 50 50 30 73 73 61 58 50 46 41 37 34 30 29 25 0.95 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 30 50 30 67 67 57 55 47 44 39 36 33 29 28 24 541 FLUO 7” FR7OLA 2 x DTT Horizontal FR7OLA-01 Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications New Construction (NW) Code NWF7U13 NWF7U18 NWF7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT 63/16” 157mm 3/16 5mm Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 63/16” 63/16” 63/16” Hole Cut : 8” 11/2” 37mm Remodel Code F7U13 F7U18 F7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 91/16” X 63/16” 145/8” 145/8” X 91/16” 91/16” X 63/16” 63/16” X ø 91/4” 235mm H 145/8” X Hole Cut : 8” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR7OLA-07 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR7OLA-14MG 542 www.contrastlighting.com FR7OLA 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF7D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF7D262 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 7” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF7D26EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 55 75° 110 60° 165 225 45° 280 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 7.6 4.3 2.7 1.9 1.4 1.1 0.8 0.7 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 45% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0602231 80 50 30 54 54 41 38 32 28 26 22 21 17 18 14 50 50 30 50 50 38 36 30 27 24 21 20 17 17 14 30 50 30 48 48 37 35 29 26 24 20 20 17 17 14 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 70 75° 140 60° 205 275 45° 340 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 9.3 5.2 3.4 2.3 1.7 1.3 1.0 0.8 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 18W Quad, 4pin 2500 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 47.5% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0602233 80 50 30 56 55 43 39 33 29 26 22 22 18 18 15 50 50 30 52 52 40 37 31 27 25 21 21 17 17 14 30 50 30 49 49 38 36 29 27 24 21 20 17 17 14 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 100 75° 195 60° 290 385 45° 485 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 13.2 7.4 4.7 3.3 2.4 1.9 1.5 1.2 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 42.1% Spacing Criteria 1.3 (0-180) 1.4 (90-270) Certificate S0602235 80 50 30 50 50 38 35 30 26 24 20 20 16 17 13 50 50 30 47 47 36 34 28 25 23 19 19 16 16 13 30 50 30 45 45 34 33 27 24 22 19 18 15 15 13 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 543 FLUO 7” FR7OLB 2 x DTT Horizontal FR7OLB-01 Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications New Construction (NW) Code NWF7U13 NWF7U18 NWF7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT 63/16” 157mm 3/16 5mm Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 10” 10” 10” X X X 63/16” 63/16” 63/16” Hole Cut : 8” 11/2” 37mm Remodel Code F7U13 F7U18 F7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 91/16” X 63/16” 145/8” 145/8” X 91/16” 91/16” X 63/16” 63/16” X ø 91/4” 235mm H 145/8” X Hole Cut : 8” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR7OLB-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR7OLB-02MG 544 www.contrastlighting.com FR7OLB 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F7D18 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F7D182 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 7” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF7U26EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 85 75° 170 60° 250 340 45° 425 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 9.9 5.6 3.6 2.5 1.8 1.4 1.1 0.9 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 13W Quad, 4pin 1800 120V 277V 347V Input Watts 30W 30W 33W Operating AMPS 0.26A 0.11A 0.10A Luminaire Efficiency 50.7% Spacing Criteria 1.1 (0-180) 1.5 (90-270) Certificate S0602232 80 50 30 60 60 47 44 37 33 30 26 25 21 22 18 50 50 30 56 56 44 42 36 32 29 26 24 21 21 17 30 50 30 54 54 43 41 34 31 28 25 24 21 20 17 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 95 75° 190 60° 285 380 45° 475 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 12.5 7.0 4.5 3.1 2.3 1.8 1.4 1.1 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 18W Quad, 4pin 2500 120V 277V 347V Input Watts 35W 35W 38W Operating AMPS 0.30A 0.13A 0.11A Luminaire Efficiency 52.8% Spacing Criteria 1.2 (0-180) 1.4 (90-270) Certificate S0602234 80 50 30 63 63 49 45 38 34 31 27 26 22 22 18 50 50 30 59 59 46 43 36 33 30 26 25 21 21 18 30 50 30 56 56 44 42 32 32 26 25 21 21 18 17 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 135 75° 270 60° 405 540 45° 675 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 17.1 9.6 6.2 4.3 3.1 2.4 1.9 1.5 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 47.3% Spacing Criteria 1.2 (0-180) 1.4 (90-270) Certificate S0602236 80 50 30 56 56 44 41 35 31 28 24 23 19 20 16 50 50 30 53 53 41 39 33 30 27 23 22 19 19 16 30 50 30 50 50 40 38 32 29 26 23 22 19 19 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 545 FLUO 7” FR7T Turbo Louver FR7T-11 2 x DTT Horizontal Damp location Compact fluorescent: 2 X CFQ-13W 2 X CFQ-18W 2 X CFQ-26W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications New Construction (NW) Code NWF7U13 NWF7U18 NWF7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X 63/16” 157mm H 10” 10” 10” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 8” Remodel Code F7U13 F7U18 F7U26 Lamp 2 X 13W DTT 2 X 18W DTT 2 X 26W DTT Base G24q-1 (4 pin) G24q-2 (4 pin) G24q-3 (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 91/16” X 63/16” 145/8” 145/8” X 91/16” 91/16” X 63/16” 63/16” X ø 9” 230mm H 145/8” X Hole Cut : 8” 75/8” 194mm Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR7T-05 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR7T-05MG 546 www.contrastlighting.com FR7T 2 x DTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF7D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF7D262 Mounting Bars • For NW and IC housings. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 7” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF6U18EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 13W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 105 75° 205 60° 315 415 45° 520 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 12.4 7.0 4.5 3.1 2.3 1.7 1.4 1.1 LUMINAIRE DIA 0.8’ 1.1’ 1.4’ 1.7’ 2.0’ 2.2’ 2.5’ 2.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificat COEFFICIENT OF UTILISATION - % Two 13W Quad, 4pin 1800 120V 277V 347V 30W 30W 33W 0.26A 0.11A 0.10A 40.1% 1.6 (0-180) 1.7 (90-270) S0602164 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 48 48 40 38 34 31 28 26 24 21 21 18 50 50 30 45 45 38 37 32 30 27 25 23 21 20 18 30 50 30 43 43 37 36 32 30 27 25 23 21 20 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 18W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 120 75° 240 60° 360 480 45° 600 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 14.2 8.2 5.1 3.5 2.6 2.0 1.6 1.3 LUMINAIRE DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificat COEFFICIENT OF UTILISATION - % Two 18W Quad, 4pin 2500 120V 277V 347V 35W 35W 38W 0.30A 0.13A 0.11A 39.8% 1.6 (0-180) 1.7 (90-270) S0601184 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 47 47 39 37 33 30 28 25 23 20 20 17 50 50 30 44 44 37 36 31 29 27 24 23 20 19 17 30 50 30 42 42 36 35 31 29 26 24 22 20 19 17 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 170 75° 340 60° 515 685 45° 860 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 21.0 11.8 7.6 5.2 3.9 2.9 2.3 1.9 LUMINAIRE DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower Lamp Type Initial Lumens Input Watts Operating AMPS Luminaire Efficiency Spacing Criteria Certificat COEFFICIENT OF UTILISATION - % Two 26W Quad, 4pin 3600 120V 277V 347V 56W 56W 57W 0.30A 0.13A 0.13A 41.1% 1.6 S0602161 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 80 50 30 49 49 39 39 34 31 29 26 24 21 21 18 50 50 30 46 46 39 37 33 31 28 25 24 21 20 18 30 50 30 44 44 38 36 32 30 27 25 23 21 20 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 547 Compact Fluorescent Energy Efficient Lighting 8” FLUO 8” FR8C Cross Louver FR8C-11 2 x DTT/TTT Horizontal Damp location Compact fluorescent: 2 X CFQ-26W 2 X CFTR-32W 2 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications 63/16” 157mm New Construction (NW) Code NWF8U26 NWF8U32 NWF8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 111/4” 111/4” 111/4” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 91/4” Remodel Code F8U26 F8U32 F8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 151/4” 151/4” 151/4” X X X 107/16” 107/16” 107/16” X X X ø 103/8” 264mm ø 81/2” 216mm H 63/16” 63/16” 63/16” ø 73/4” 198mm Hole Cut : 91/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR8C-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR8C-05MG 550 www.contrastlighting.com FR8C 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F8D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F8D262 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 8” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF8U26EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 205 75° 410 60° 615 820 45° 1025 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 28.3 15.9 10.2 7.1 5.2 4.0 3.1 2.5 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 57.5% Spacing Criteria 1.2 Certificate S0602172 80 50 30 69 69 56 53 46 42 38 33 32 27 27 23 50 50 30 64 64 53 51 44 40 36 32 30 27 26 22 30 50 30 61 61 51 50 42 40 35 32 30 26 26 22 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 340 75° 680 60° 1020 1360 45° 1700 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 46.7 26.3 16.8 11.7 8.6 6.6 5.2 4.2 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 32W Triple Tube, 4pin 4800 120V 277V 347V Input Watts 69W 67W 62W Operating AMPS 0.58A 0.26A 0.19A Luminaire Efficiency 67.8% Spacing Criteria 1.1 (0-180) 1.4 (90-270) Certificate S0602212 80 50 30 81 81 67 63 55 50 45 40 38 33 32 27 50 50 30 75 75 63 60 52 48 43 39 37 32 31 27 30 50 30 72 72 61 59 51 47 42 38 36 32 31 27 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 325 75° 650 60° 980 1305 45° 1630 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 44.8 25.2 16.1 11.2 8.2 6.5 5.0 4.0 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 42W Triple Tube, 4pin 6400 120V 277V 347V Input Watts 91W 90W 80W Operating AMPS 0.76A 0.32A 0.25A Luminaire Efficiency 67.4% Spacing Criteria 1.4 (0-180) 1.5 (90-270) Certificate S0602202 80 50 30 80 80 65 62 52 47 43 37 35 30 30 24 50 50 30 75 75 62 59 50 46 41 36 34 29 29 24 30 50 30 72 72 60 57 48 45 40 36 33 29 28 24 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 551 FLUO 8” FR8O Downlight FR8O-11 2 x DTT/TTT Horizontal Damp location Compact fluorescent: 2 X CFQ-26W 2 X CFTR-32W 2 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Matte iridescence free: Add «M» after the trim code. Ex.: FR8OM-06 Housings Specifications 63/16” 157mm New Construction (NW) Code NWF8U26 NWF8U32 NWF8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 111/4” 111/4” 111/4” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 91/4” Remodel Code F8U26 F8U32 F8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W ø 81/2” 216mm H 151/4” X 107/16” X 63/16” 151/4” 151/4” X 107/16” 107/16” X 63/16” 63/16” X X ø 103/8” 264mm ø 73/4” 198mm Hole Cut : 91/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR8O-08 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR8O-11MG 552 www.contrastlighting.com FR8O 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF8D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF8D422 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Optional: Low iridescent matte finish. Add «M» to housing code. Ex: NWF8U26M Trims Plated or painted steel Efficient CFL Housings Socket & Lamp Bases High temperature-rated 130˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM#283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P 8” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF8U32EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 200 75° 405 60° 605 805 45° 1010 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 25.3 14.2 9.1 6.3 4.6 3.6 2.8 2.3 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 67.4% Spacing Criteria 1.1 (0-180) 1.4 (90-270) Certificate S0602171 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Matte Reflector Multiplier Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0.95 80 50 30 80 80 65 61 52 47 42 36 35 29 29 24 50 50 30 75 75 61 58 49 45 40 35 33 29 28 24 30 50 30 72 72 59 57 48 44 39 35 33 28 28 24 2 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 340 75° 380 60° 1020 1360 45° 1700 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 43.2 24.3 15.6 10.8 7.9 6.1 4.8 3.9 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Two 32W Triple Tube, 4pin 4800 120V 277V 347V Input Watts 69W 67W 62W Operating AMPS 0.58A 0.26A 0.19A Luminaire Efficiency 73.3% Spacing Criteria 1.1 (0-180) 1.5 (90-270) Certificate S0602211 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Matte Reflector Multiplier Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0.95 80 50 30 87 87 71 67 57 52 47 41 39 33 33 28 50 50 30 81 81 67 64 54 50 45 40 37 32 32 27 30 50 30 78 78 65 62 53 49 44 39 37 32 31 27 2 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 325 75° 650 60° 980 1305 45° 1630 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 44.9 25.2 16.2 11.2 8.2 6.3 5.0 4.0 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Two 42W Triple Tube, 4pin 6400 120V 277V 347V Input Watts 91W 90W 80W Operating AMPS 0.76A 0.32A 0.25A Luminaire Efficiency 70.5% Spacing Criteria 1.2 (0-180) 1.5 (90-270) Certificate S0602201 Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Matte Reflector Multiplier Zonal Cavity Method Effective Floor Cavity Reflectance 20% 0.95 80 50 30 84 84 67 63 53 48 43 37 35 29 30 24 50 50 30 78 78 63 60 51 48 41 36 34 29 29 24 30 50 30 75 75 61 59 49 45 40 35 33 28 28 23 NOTES 553 FLUO 8” FR8OLA 2 x DTT/TTT Horizontal FR8OLA-01 Damp location Compact fluorescent: 2 X CFQ-26W 2 X CFTR-32W 2 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications 63/16” 157mm New Construction (NW) Code NWF8U26 NWF8U32 NWF8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 111/4” 111/4” 111/4” X X X 63/16” 63/16” 63/16” 13/8” 35mm 3/16” 5mm Hole Cut : 91/4” Remodel Code F8U26 F8U32 F8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 107/16” X 63/16” 151/4” 151/4” X 107/16” 107/16” X 63/16” 63/16” X ø 101/2” 267mm H 151/4” X Hole Cut : 91/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR8OLA-04 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR8OLA-11MG 554 www.contrastlighting.com FR8OLA 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: NWF8D26 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: NWF8D262 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 8” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF8D26EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 115 75° 230 60° 345 460 45° 575 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 15.6 8.8 5.6 3.9 2.9 2.2 1.7 1.4 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 49% Spacing Criteria 1.3 Certificate S0604191 80 50 30 58 58 44 41 34 30 28 23 23 19 19 15 50 50 30 54 54 41 39 32 29 26 22 22 18 18 15 30 50 30 51 51 40 38 31 28 25 22 21 18 18 15 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 150 75° 305 60° 460 615 45° 770 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 20.4 11.5 7.3 5.1 3.7 2.9 2.3 1.8 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3’ 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 32W Triple Tube, 4pin 4800 120V 277V 347V Input Watts 69W 67W 62W Operating AMPS 0.58A 0.26A 0.19A Luminaire Efficiency 52.6% Spacing Criteria 1.1 (0-180) 1.3 (90-270) Certificate S0604195 80 50 30 62 62 49 46 39 34 31 27 26 22 22 18 50 50 30 58 58 46 43 36 33 30 26 25 21 21 18 30 50 30 55 55 44 42 35 32 29 26 24 21 21 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 265 75° 465 60° 665 865 45° 1065 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 31.2 17.5 11.2 7.8 5.7 4.4 3.5 2.8 DIA 1.7’ 2.3’ 2.9’ 3.5’ 4.0’ 4.6’ 5.2’ 5.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 42W Triple Tube, 4pin 6400 120V 277V 347V Input Watts 91W 90W 80W Operating AMPS 0.76A 0.32A 0.25A Luminaire Efficiency 54.1% Spacing Criteria 1.2 (0-180) 1.3 (90-270) Certificate S0604193 80 50 30 64 64 49 45 38 33 30 25 25 20 21 17 50 50 30 59 59 45 42 35 31 28 24 24 20 20 16 30 50 30 56 56 43 41 34 30 27 24 23 19 19 16 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 555 FLUO 8” FR8OLB 2 x DTT/TTT Horizontal FR8OLB-01 Damp location Compact fluorescent: 2 X CFQ-26W 2 X CFTR-32W 2 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications 63/16” 157mm New Construction (NW) Code NWF8U26 NWF8U32 NWF8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 111/4” 111/4” 111/4” X X X 63/16” 63/16” 63/16” 13/8” 35mm 3/16” 5mm Hole Cut : 91/4” Remodel Code F8U26 F8U32 F8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W X 107/16” X 63/16” 151/4” 151/4” X 107/16” 107/16” X 63/16” 63/16” X ø 101/2” 267mm H 151/4” X Hole Cut : 91/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR8OLB-12BR For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR8OLB-06MG 556 www.contrastlighting.com FR8OLB 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F8D32 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F8D322 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 8” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF8U32EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Trims Plated or painted steel Photometric Data 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 154 75° 308 60° 462 616 45° 770 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 21.2 11.9 7.6 5.3 3.9 3 2.4 1.9 DIA 1.4’ 1.9’ 2.4’ 2.9’ 3.3’ 3.8’ 4.3 4.8’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3420 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 52.6% Spacing Criteria 1.1 (0-180) 1.3 (90-270) Certificate S0604192 80 50 30 62 62 49 46 39 34 31 27 26 22 22 18 50 50 30 58 58 46 43 36 33 30 26 25 21 21 18 30 50 30 55 55 44 42 35 32 29 26 24 21 21 18 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 275 75° 550 60° 825 1100 45° 1375 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 37.8 21.3 13.6 9.4 6.9 5.3 4.2 3.4 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 32W Triple Tube, 4pin 4800 120V 277V 347V Input Watts 69W 67W 62W Operating AMPS 0.58A 0.26A 0.19A Luminaire Efficiency 55.4% Spacing Criteria 0.9 (0-180) 1.3 (90-270) Certificate S0604196 80 50 30 66 66 52 49 42 38 34 30 29 24 25 21 50 50 30 61 61 49 47 40 36 33 29 28 24 24 20 30 50 30 58 58 47 45 38 35 32 28 27 23 23 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 0 75° 400 60° 800 1200 45° 1600 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 43.3 24.4 15.6 10.8 8.0 6.1 4.8 3.9 DIA 1.0’ 1.3’ 1.7’ 2.0’ 2.3’ 2.7’ 3.0’ 3.3’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILIZATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 42W Triple Tube, 4pin 3200 120V 277V 347V Input Watts 91W 90W 80W Operating AMPS 0.76A 0.32A 0.25A Luminaire Efficiency 59.6% Spacing Criteria 1.0 (0-180) 1.3 (90-270) Certificate S0604194 80 50 30 71 71 55 51 43 38 35 30 29 24 25 20 50 50 30 65 65 51 48 41 37 33 29 28 24 24 20 30 50 30 62 62 49 47 39 36 32 28 27 23 23 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 557 FLUO 8” FR8T Turbo Louver FR8T-11 2 x DTT/TTT Horizontal Damp location Compact fluorescent: 2 X CFQ-26W 2 X CFTR-32W 2 X CFTR-42W ** Lamps must meet ANSI requirements.** Reflector Standard: semi-specular low iridescence aluminum Housings Specifications 63/16” 157mm New Construction (NW) Code NWF8U26 NWF8U32 NWF8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 191/8” 191/8” 191/8” X X X H 111/4” 111/4” 111/4” X X X 63/16” 63/16” 63/16” 3/16” 5mm Hole Cut : 91/4” Remodel Code F8U26 F8U32 F8U42 Lamp 2 X 26W 2 X 32W 2 X 42W DTT TTT TTT Base G24q-3 GX24q-3 GX24q-4 (4 pin) (4 pin) (4 pin) Volts 120-277V 120-277V 120-277V Ballast Electronic Electronic Electronic L W 151/4” 151/4” 151/4” X X X H 107/16” 107/16” 107/16” X X X 63/16” 63/16” 63/16” ø 103/8” 264mm ø 8” 203mm Hole Cut : 91/4” Trim finishes -01 -02 -03 -04 -04BR -05 -06 -07 -08 -11 -12BR -13 -14 -15 -16 White Black Gold Plated 24k Chrome Brushed Chrome Architectural Bronze Antique Copper Antique Brass Antique Silver Matte White Brushed Nickel Satin Nickel Almond Metallic Grey Satin Chrome Ex.: FR8T-13 For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14 and -15. See page 576 for more details. Add MG to code. Ex.: FR8T-05MG 558 www.contrastlighting.com FR8T 2 x DTT/TTT Horizontal Technical Specifications Dimming Capability • 120V: For dimming capability, change «U» to «D» in codes of housing of 18W to 42W. Ex.: F8D42 • 277V: For dimming capability, change «U» to «D» and add «2» at the end of the housing code of 18W to 42W. Ex: F8D422 Mounting Bars • For NW. • Adjustable and lockable from 10” to 24”. • Lockable integral T-Bar tabs. May be hung from trusses or suspended ceilings. Housing Features • Galvanized steel • Below ceiling accessible • Keyhole on socket assembly for easier installation • See specs in Housing Section Locking System • Perfect fit to ceiling • No light leak • Hooks PAT #CAN. 2.088.648 and #USA. 5.377.088 • Take up to 7/8” thick ceilings Reflector 0.04’’aluminium reflector with low iridescence semi specular clear finish. Trims Plated or painted steel Efficient CFL Housings Socket & Lamp Bases High temperature-rated 120˚C instead of 90˚C Listings • cULus Listed for through branch wiring and damp location. 1 IC Housings meet: • Airtight ASTM#283 • State of California Stat Title 24 requirements. Add «W» to code. Ex: ISF2675RU13W • City of Chicago For ceiling air Plenum add «P» to code. Ex: ISF2675RU13P 8” FLUO Emergency Ballast Available for New Construction housing (NW) with horizontal lamp only (120-277V). Add «EM» to housing code. Ex: NWF8U32EM Ballast • 120V through 277V Class P • HPF Electronic ballast • 347V HPF Electronic ballast: Available in Canada. For ordering change «U» to «3». • Program start without flickering • <10% THD and End of life lamp protection • 5 Year Warranty Photometric Data 2 X 26W Elect. DTT CANDLEPOWER DISTRIBUTION Candelas 90° 170 75° 335 60° 505 675 45° 840 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 22.4 12.6 8.1 5.6 4.1 3.2 2.5 2.0 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILISATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 26W Quad, 4pin 3600 120V 277V 347V Input Watts 56W 56W 57W Operating AMPS 0.47A 0.21A 0.17A Luminaire Efficiency 49.7% Spacing Criteria 1.5 (0-180) 1.6 (90-270) Certificat S0602173 80 50 30 59 55 49 47 40 39 34 32 28 27 24 23 50 50 30 55 55 47 45 39 36 32 29 27 24 23 20 30 50 30 53 53 45 43 38 35 32 29 27 24 23 20 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 32W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 335 75° 675 60° 1015 1350 45° 1690 0° 15° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 39.8 22.4 14.3 9.9 7.3 5.6 4.4 3.6 DIA 1.2’ 1.6’ 2’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower 30° LUMINAIRE COEFFICIENT OF UTILISATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 32W Triple Tube, 4pin 4800 120V 277V 347V Input Watts 69W 67W 62W Operating AMPS 0.58A 0.26A 0.19A Luminaire Efficiency 59.2% Spacing Criteria 1.3 (0-180) 1.5 (90-270) Certificat S0602213 80 50 30 71 71 59 56 49 45 41 37 35 30 30 25 50 50 30 66 66 56 54 47 44 39 36 33 30 29 25 30 50 30 63 63 54 53 46 43 38 35 33 29 28 25 Zonal Cavity Method Effective Floor Cavity Reflectance 20% 2 X 42W Elect. TTT CANDLEPOWER DISTRIBUTION Candelas 90° 325 75° 650 60° 980 1305 45° 1630 0° 15° 30° CONE OF LIGHT Distance 06’ 08’ 10’ 12’ 14’ 16’ 18’ 20’ FC 44.8 25.2 16.1 11.2 8.2 6.3 5.0 4.0 DIA 1.2’ 1.6’ 2.0’ 2.4’ 2.8’ 3.2’ 3.6’ 4.0’ Beam Edge defined as 50% of Maximum Nadir Candlepower LUMINAIRE COEFFICIENT OF UTILISATION - % Lamp Type Initial Lumens Ceiling Reflect % Wall Reflect % RCR 0 2 4 6 8 10 Two 42W Triple Tube, 4pin 6400 120V 277V 347V Input Watts 91W 90W 80W Operating AMPS 0.76A 0.32A 0.25A Luminaire Efficiency 59.5% Spacing Criteria 1.5 (0-180) 1.5 (90-270) Certificat S0602203 80 50 30 71 71 58 55 48 44 39 35 33 28 28 24 50 50 30 66 66 55 53 46 42 38 34 32 28 27 23 30 50 30 63 63 54 52 44 41 37 34 31 28 26 23 Zonal Cavity Method Effective Floor Cavity Reflectance 20% NOTES 559 Housing Specifications Compact Fluorescent 4 6 7 8” , , & CFL HOUSINGS 4” REMODEL 4’’ Vertical Compact Fluorescent PRODUCTS CODES F2000 F2000L F2000U13 F2000313 F2000U18 F2000318 F2000U26 F2000326 F2000D18 F2000D182 F2000D26 F2000D262 F2000LU18 F2000L318 F2000LU26 F2000L326 F2000LU32 F2000L332 F2000LD18 F2000LD182 F2000LD26 F2000LD262 F2000LD32 F2000LD322 HOLE CUT BALLAST VOLTAGE ø 41/4” Magnetic HPF 120V ø 41/4” Magnetic HPF (108mm) (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” (108mm) Electronic 120V 120/277V Electronic Electronic 347V 120/277V Electronic Electronic 347V 120/277V Electronic 347V Electronic Electronic 120V 120/277V Electronic Electronic Electronic 120V 120/277V 120/277V Electronic Electronic 347V 120/277V Electronic Electronic 347V 120/277V Electronic 347V Electronic Electronic 120V 120/277V Electronic Electronic 120V 120/277V Electronic Electronic 120V 120/277V • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 562 www.contrastlighting.com LENGTH 13” WIDTH 51/8” HEIGHT SOURCE 4” 13W DTT (331mm) (131mm) (102mm) 153/4” 51/8” 71/4” (400mm) (131mm) (184mm) 139/16” 51/8” 61/16” 13W DTT 13W DTT (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” 13W DTT 18W TTT (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” 18W TTT 26W TTT (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” 26W TTT 18W TTT (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” 18W TTT 26W TTT (345 mm) (131mm) (154mm) 139/16” 51/8” 61/16” 26W TTT 18W TTT (345 mm) (131mm) (154mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” 18W TTT 26W TTT (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” 26W TTT 26W TTT (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” 26W TTT 18W TTT (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” 18W TTT 26W TTT (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 1311/16” 51/8” 71/4” (348mm) (131mm) (184mm) 26W TTT 26W TTT 26W TTT BASE GX23-2 (2 pin) GX23-2 (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (2 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) Continued on next page... REMODEL 4’’ Vertical Compact Fluorescent PRODUCTS CODES F2575R F2675R F2575RU13 F2575R313 F2575RU18 F2575R318 F2575RU26 F2575R326 F2575RD18 F2575RD182 F2575RD26 F2575RD262 F2675RD18 F2675RD182 F2675RD32 F2675RD322 F2675RU13 F2675R313 F2675RU18 F2675R318 F2675RU32 F2675R332 HOLE CUT BALLAST VOLTAGE ø 45/8” Magnetic HPF 120V ø 45/8” Magnetic HPF (118mm) (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) Electronic 120V 120/277V Electronic Electronic 347V 120/277V Electronic Electronic 347V 120/277V Electronic 347V Electronic Electronic 120V 120/277V Electronic Electronic 120V 120/277V Electronic Electronic 120V 120/277V Electronic Electronic Electronic 120V 120/277V 120/277V Electronic Electronic 347V 120/277V Electronic Electronic 347V 120/277V Electronic 347V LENGTH 143/8” WIDTH 59/16” HEIGHT SOURCE 6” 13W DTT (375mm) (140mm) (149mm) 143/8” 59/16” 6” (375mm) (140mm) (149mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 13W DTT 13W DTT 13W DTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 18W TTT 18W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 26W TTT 26W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 18W TTT 18W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 26W TTT 26W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 18W TTT 18W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 26W TTT 26W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 13W DTT 13W DTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 18W TTT 18W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” 26/32W TTT 26/32W TTT (361mm) (141mm) (180mm) 143/16” 59/16” 71/16” (361mm) (141mm) (180mm) BASE GX23-2 CFL HOUSINGS 4” ... continued (2 pin) GX23-2 (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 563 CFL HOUSINGS 4” NEW CONSTRUCTION 4’’ Vertical Compact Fluorescent PRODUCTS CODES NW2000LF NWF2000U13 NWF2000313 NWF2000U18 NWF2000318 NWF2000U26 NWF2000326 NWF2000D18 NWF2000D182 NWF2000D26 NWF2000D262 NWF2000LU18 NWF2000L318 NWF2000LU26 NWF2000L326 NWF2000LU32 NWF2000L332 NWF2000LD18 NWF2000LD182 NWF2000LD26 NWF2000LD262 NWF2000LD32 NWF2000LD322 HOLE CUT BALLAST VOLTAGE ø 41/4” Magnetic HPF 120V (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø Electronic Electronic Electronic Electronic Electronic 41/4” Electronic ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming (108mm) (108mm) (108mm) (108mm) (108mm) ø 41/4” (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) ø 41/4” (108mm) Electronic Electronic Electronic Electronic Electronic ø 41/4” Electronic ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming (108mm) (108mm) (108mm) (108mm) (108mm) (108mm) (108mm) 120/277V 347V 120/277V 347V 120/277V 347V 120V 277V 120V 277V 120/277V 347V 120/277V 347V 120/277V 347V 120V 277V 120V 277V 120V 277V LENGTH 1411/16” WIDTH 10” HEIGHT SOURCE 71/4” 13W DTT (374mm) (254mm) (184mm) 1411/16” 10” 6” 13W DTT (374mm) (254mm) (153mm) 1411/16” 10” 6” 13W DTT 18W TTT (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 6” 18W TTT 26W TTT (374mm) (254mm) (153mm) 1411/16” 10” 6” 26W TTT 18W TTT (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 6” (374mm) (254mm) (153mm) 1411/16” 10” 71/4” (374mm) (254mm) (184mm) 1411/16” 10” 71/4” (374mm) 1411/16” (374mm) 1411/16” (254mm) (184mm) 10” 71/4” (254mm) (184mm) 10” 71/4” (374mm) (254mm) (184mm) 1411/16” 10” 71/4” (374mm) (254mm) (184mm) 1411/16” 10” 71/4” (374mm) 1411/16” (374mm) 1411/16” (254mm) (184mm) 10” 71/4” (254mm) (184mm) 10” 71/4” (374mm) (254mm) (184mm) 1411/16” 10” 71/4” (374mm) (254mm) (184mm) 1411/16” 10” 71/4” (374mm) 1411/16” (374mm) 1411/16” (374mm) 18W TTT 26W TTT 26W TTT 18W TTT 18W TTT 26W TTT 26W TTT 32W TTT 32W TTT 18W TTT 18W TTT 26W TTT 26W TTT (254mm) (184mm) 10” (254mm) 71/4” (184mm) 32W TTT 10” 71/4” 32W TTT (254mm) (184mm) BASE GX23-2 (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (2 pin) GX24q-3 (4 pin) GX24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-1 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) Continued on next page... Emergency ballast available for New Construction housing with horizontal lamps only (120/277V). Add «EM» to housing code. Ex.: NWF6HU13EM • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 564 www.contrastlighting.com ... continued Vertical Compact Fluorescent PRODUCTS CODES NW2675F NWF2575RU13 NWF2575R313 NWF2575RU18 NWF2575R318 NWF2575RU26 NWF2575R326 NWF2575RD18 NWF2575RD182 NWF2575RD26 NWF2575RD262 NWF2675RU13 NWF2675R313 NWF2675RU18 NWF2675R318 NWF2675RU32 HOLE CUT BALLAST VOLTAGE ø 45/8” Magnetic HPF 120V (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) Electronic Electronic Electronic Electronic Electronic ø 45/8” Electronic ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” (118mm) (118mm) (118mm) (118mm) (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) ø 45/8” ø 45/8” (118mm) (118mm) Electronic Electronic Electronic Electronic Electronic NWF2675R332 ø 45/8” (118mm) Electronic NWF2675RD18 ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming NWF2675RD182 NWF2675RD32 NWF2675RD322 (118mm) (118mm) (118mm) (118mm) 120/277V 347V 120/277V 347V 120/277V 347V 120V 277V 120V 277V 120V 347V 120V 347V 120V 347V 120V 277V 120V 277V LENGTH 1411/16” WIDTH 10” HEIGHT SOURCE 6” 13W DTT (374mm) (254mm) (153mm) 1411/16” 10” 75/8” (374mm) 1411/16” (374mm) 1411/16” (254mm) (194mm) 10” 75/8” (194mm) 10” 75/8” 18W TTT 18W TTT (254mm) (194mm) 1411/16” 10” 75/8” (374mm) (254mm) (194mm) 1411/16” 10” 75/8” 1411/16” (374mm) 1411/16” (254mm) (194mm) 10” 75/8” 10” 75/8” 18W TTT 18W TTT (254mm) (194mm) 10” 75/8” (374mm) (254mm) (194mm) 1411/16” 10” 75/8” (374mm) 1411/16” (254mm) (194mm) 10” 75/8” 10” 75/8” 13W DTT 13W DTT (254mm) (194mm) 10” 75/8” (374mm) (254mm) (194mm) 1411/16” 10” 75/8” (374mm) 1411/16” (254mm) (194mm) 10” 75/8” 10” 75/8” 26/32W TTT 26/32W TTT (254mm) (194mm) 10” 75/8” (374mm) (254mm) (194mm) 1411/16” 10” 75/8” (374mm) 1411/16” (254mm) (194mm) 10” 75/8” 18W TTT 18W TTT (254mm) (194mm) 10” 75/8” 26/32W TTT 26/32W TTT (374mm) (254mm) (194mm) 1411/16” 10” 75/8” (374mm) 18W TTT (194mm) 1411/16” 1411/16” 18W TTT (254mm) (374mm) (374mm) 26W TTT (194mm) 1411/16” 1411/16” 26W TTT (254mm) (374mm) (374mm) 26W TTT (194mm) 1411/16” 1411/16” 26W TTT (254mm) (374mm) (374mm) 13W DTT (254mm) (374mm) (374mm) 13W DTT (254mm) (194mm) BASE GX23-2 CFL HOUSINGS NEW CONSTRUCTION 4’’ (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (2 pin) GX24q-3 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) G24q-1 (2 pin) G24q-1 (2 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 565 CFL HOUSINGS 4” INSULATED CEILING 4’’ Vertical Compact Fluorescent PRODUCTS CODES ISF2000 ISF2000L ISF2000U13 ISF2000313 ISF2000U18 ISF2000318 ISF2000D18 ISF2000D182 ISF2000LU18 ISF2000L318 ISF2000LD18 ISF2000LD182 ISF2575R ISF2675R ISF2675RU13 ISF2675R313 ISF2675RU18 ISF2675R318 ISF2675RU32 ISF2675R332 ISF2675RD18 ISF2675RD182 ISF2675RD32 ISF2675RD322 HOLE CUT BALLAST VOLTAGE ø 41/4” Magnetic HPF 120V ø 41/4” Magnetic HPF (108mm) (108mm) ø 41/4” (108mm) ø 41/4” ø 41/4” (108mm) (108mm) Electronic Electronic Electronic ø 41/4” Electronic ø 41/4” Electronic Dimming 41/4” Electronic Dimming (108mm) (108mm) ø (108mm) ø 41/4” (108mm) Electronic ø 41/4” Electronic ø 41/4” Electronic Dimming ø 41/4” Electronic Dimming ø 45/8” Magnetic HPF ø 45/8” Magnetic HPF (108mm) (108mm) (108mm) (118mm) (118mm) ø 45/8” ø 45/8” ø 45/8” (118mm) (118mm) (118mm) ø 45/8” (118mm) ø 45/8” (118mm) Electronic Electronic Electronic Electronic Electronic ø 45/8” Electronic ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming ø 45/8” Electronic Dimming 45/8” Electronic Dimming (118mm) (118mm) (118mm) (118mm) ø (118mm) Airtight - ASTM E283 Title 24 - Add «W» to code Chicago Plenum - «P» to code 566 www.contrastlighting.com 120V 120/277V 347V 120/277V 347V 120V 277V 120V 277V 120V 277V 120V 120V 120/277V 347V 120/277V 347V 120/277V 347V 120V 277V 120V 277V LENGTH 153/16” WIDTH 81/8” HEIGHT SOURCE 71/2” 13W DTT (386mm) (207mm) (191mm) 153/16” 81/8” 71/2” (386mm) (207mm) (191mm) 193/8” 10” 61/16” (492mm) 193/8” (492mm) 193/8” (179mm) 10” (254mm) 61/16” (179mm) 13W DTT 10” 61/16” 18W TTT (254mm) (179mm) 193/8” 10” 61/16” (492mm) (254mm) (179mm) 193/8” 10” 61/16” 193/8” 10” 61/16” 18W TTT 18W TTT (254mm) (179mm) 10” 61/16” (492mm) (254mm) (179mm) 193/8” 10” 61/16” (492mm) 193/8” (254mm) (179mm) 10” 61/16” 10” 61/16” 18W TTT 13W DTT (254mm) (179mm) 10” 61/16” (386mm) (254mm) (179mm) 153/16” 10” 61/16” (492mm) 193/8” (492mm) 193/8” (254mm) (179mm) 10” 61/16” 10” (254mm) 61/16” (179mm) 13W DTT 10” 61/16” 18W TTT (254mm) (179mm) 10” 61/16” (492mm) (254mm) (179mm) 193/8” 10” 61/16” (492mm) 193/8” 10” (254mm) 61/16” (179mm) 26/32W TTT 10” 61/16” 18W TTT (254mm) (179mm) 10” 61/16” (492mm) (254mm) (179mm) 193/8” 10” 61/16” (492mm) 26/32W TTT (179mm) 193/8” 193/8” 18W TTT (254mm) (492mm) (492mm) 13W DTT (179mm) 193/8” 193/8” 13W DTT (254mm) (492mm) (492mm) 18W TTT (179mm) 153/16” 193/8” 18W TTT (254mm) (492mm) (386mm) 18W TTT (179mm) 193/8” 193/8” 18W TTT (254mm) (492mm) (492mm) 13W DTT (254mm) (492mm) (492mm) 13W DTT (254mm) (179mm) 10” 61/16” (254mm) (179mm) 18W TTT 26/32W TTT 26/32W TTT BASE GX23-2 (2 pin) GX23-2 (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX23-2 (2 pin) GX23-2 (2 pin) G24q-1 (4 pin) G24q-1 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) GX24q-2 (4 pin) GX24q-2 (4 pin) GX24q-3 (4 pin) GX24q-3 (4 pin) • Insulated Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings REMODEL 6’’ Horizontal Compact Fluorescent PRODUCTS CODES F6HU13 F6H313 F6HU13S F6H313S F6HU18 F6H318 F6HU18S F6H318S F6HU26 F6H326 F6HU26S F6H326S F6HU32S F6H332S F6HD18 F6HD182 F6HD18S F6HD18S2 F6HD26 F6HD262 F6HD26S F6HD26S2 F6HD32S F6HD32S2 HOLE CUT ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” ø 63/4” (172mm) (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” ø 63/4” (172mm) (172mm) ø 63/4” (172mm) ø 63/4” (172mm) BALLAST Electronic Electronic Electronic Electronic Electronic Electronic Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) 120/277V 347V 120/277V 347V 120/277V 347V 120/277V Electronic Electronic (172mm) 347V Electronic ø 63/4” (172mm) 120/277V Electronic ø (172mm) 347V Electronic 63/4” (172mm) 120/277V 141/8” Electronic ø (172mm) LENGTH Electronic 63/4” (172mm) VOLTAGE Electronic 347V 120/277V 347V 120V 277V 120V 277V 120V 277V 120V 277V 120V 277V WIDTH HEIGHT SOURCE BASE 8” 73/16” 2 X 13W DTT G24q-1 (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 X 13W DTT G24q-1 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 13W DTT G24q-1 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 13W DTT G24q-1 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 X 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 X 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 X 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 X 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 32W TTT GX24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 X 32W TTT GX24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 x 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 x 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 x 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 x 18W DTT G24q-2 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 x 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 2 x 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 x 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 x 26W DTT G24q-3 (4 pin) (359mm) (204mm) (183mm) 141/8” 8” 73/16” 1 x 32W TTT GX24q-3 1 x 32W TTT GX24q-3 (359mm) (204mm) (183mm) 141/8” 8” 73/16” (359mm) (204mm) (183mm) CFL HOUSINGS 6” (4 pin) (4 pin) (4 pin) • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 567 CFL HOUSINGS 6” NEW CONSTRUCTION 6’’ Horizontal Compact Fluorescent PRODUCTS CODES NWF6HU13 NWF6H313 NWF6HU13S NWF6H313S NWF6HU18 NWF6H318 NWF6HU18S NWF6H318S NWF6HU26 NWF6H326 NWF6HU26S NWF6H326S NWF6HU32S NWF6H332S NWF6HD18 NWF6HD182 NWF6HD18S NWF6HD18S2 NWF6HD26 NWF6HD262 NWF6HD26S NWF6HD26S2 NWF6HD32S NWF6HD32S2 HOLE CUT ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” ø 63/4” (172mm) (172mm) ø 63/4” (172mm) ø 63/4” (172mm) ø 63/4” ø 63/4” (172mm) (172mm) ø 63/4” (172mm) ø 63/4” (172mm) BALLAST Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic Electronic ø 63/4” ø 63/4” Electronic ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming ø 63/4” Electronic Dimming (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) Electronic VOLTAGE LENGTH 120/277V 191/8” 347V 120/277V 347V 120/277V 347V 120/277V 347V 120/277V 347V 120/277V 347V 120/277V 347V 120V 277V 120V 277V 120V 277V 120V 277V 120V 277V WIDTH HEIGHT SOURCE BASE 10” 73/16” 2 X 13W DTT G24q-1 (486mm) (254mm) (183mm) 191/8” 10” 73/16” 2 X 13W DTT G24q-1 (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 13W DTT G24q-1 568 www.contrastlighting.com (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 13W DTT G24q-1 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 2 X 18W DTT G24q-2 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 2 X 18W DTT G24q-2 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 18W DTT G24q-2 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 18W DTT G24q-2 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 2 X 26W DTT G24q-3 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 2 X 26W DTT G24q-3 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 26W DTT G24q-3 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 26W DTT G24q-3 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 32W TTT GX24q-3 (4 pin) (486mm) (254mm) (183mm) 191/8” 10” 73/16” 1 X 32W TTT GX24q-3 (4 pin) (486mm) (254mm) (183mm) 173/16” 81/2” 73/16” 2 x 18W DTT G24q-2 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 2 x 18W DTT G24q-2 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 1 x 18W DTT G24q-2 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 1 x 18W DTT G24q-2 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 2 x 26W DTT G24q-3 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 2 x 26W DTT G24q-3 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 1 x 26W DTT G24q-3 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 1 x 26W DTT G24q-3 (4 pin) (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” 1 x 32W TTT GX24q-3 1 x 32W TTT GX24q-3 (437mm) (216mm) (183mm) 173/16” 81/2” 73/16” (437mm) (216mm) (183mm) Emergency ballast available for New Construction housing with horizontal lamps only (120/277V). Add «EM» to housing code. Ex.: NWF6HU13EM • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings (4 pin) (4 pin) (4 pin) (4 pin) REMODEL 6’’ Vertical Compact Fluorescent PRODUCTS CODES F6VU13 F6V313 F6VU18 F6V318 F6VU42 F6V342 F6VD18 F6VD182 F6VD42 F6VD422 HOLE CUT BALLAST VOLTAGE ø 63/4” Electronic 120/277V ø 63/4” Electronic 347V ø 63/4” Electronic 120/277V (172mm) (172mm) (172mm) ø 63/4” (172mm) Electronic 347V ø 63/4” Electronic 120/277V ø 63/4” Electronic 347V ø 63/4” Electronic 120V ø 63/4” Electronic 277V ø 63/4” Electronic 120V ø 63/4” Electronic 277V (172mm) (172mm) (172mm) (172mm) (172mm) (172mm) LENGTH 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) 143/16” (360mm) WIDTH 8” (165mm) 8” (165mm) 8” HEIGHT SOURCE BASE 93/16” 1 X 13W DTT G24q-1 (4 pin) 93/16” 1 X 13W DTT G24q-1 (4 pin) (204mm) (233mm) (165mm) (233mm) 93/16” 1 X 18W DTT G24q-2 (4 pin) 8” 93/16” 1 X 18W DTT G24q-2 (4 pin) 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) 93/16” 1 X 18W DTT G24q-2 (4 pin) 93/16” 1 X 18W DTT G24q-2 (4 pin) 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) (165mm) 8” (165mm) 8” (165mm) 8” (165mm) 8” (165mm) 8” (165mm) 8” (165mm) (233mm) 93/16” (233mm) 93/16” (233mm) (233mm) (233mm) 93/16” (233mm) 93/16” (233mm) CFL HOUSINGS 6” • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 569 CFL HOUSINGS 6” NEW CONSTRUCTION 6’’ Vertical Compact Fluorescent PRODUCTS CODES HOLE CUT 63/4” BALLAST VOLTAGE LENGTH 120/277V 191/8” NWF6VU13 ø (172mm) NWF6V313 ø 63/4” (172mm) Electronic 347V NWF6VU18 ø 63/4” (172mm) Electronic 120/277V 63/4” Electronic NWF6V318 ø (172mm) Electronic 347V NWF6VU42 ø 63/4” (172mm) Electronic 120/277V NWF6V342 ø 63/4” (172mm) Electronic 347V NWF6VD18 ø 63/4” (172mm) Electronic Dimming 120V NWF6VD182 ø 63/4” (172mm) Electronic Dimming 277V NWF6VD42 ø 63/4” (172mm) Electronic Dimming 120V NWF6VD422 ø 63/4” (172mm) Electronic Dimming 277V • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 570 www.contrastlighting.com (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” WIDTH HEIGHT SOURCE BASE (254mm) 10” 93/16” (233mm) 1 X 13W DTT G24q-1 (4 pin) 10” 93/16” 1 X 13W DTT G24q-1 (4 pin) 93/16” 1 X 18W DTT G24q-2 (4 pin) 93/16” 1 X 18W DTT G24q-2 (4 pin) 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) (254mm) 10” (254mm) 10” (254mm) 10” (254mm) 10” (254mm) (233mm) (233mm) 93/16” (233mm) 93/16” (233mm) (486mm) (254mm) (233mm) 93/16” 1 X 18W DTT G24q-2 (4 pin) 191/8” 10” 93/16” 1 X 18W DTT G24q-2 (4 pin) 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) 1 X 26W DTT 1 X 26/32W TTT 1 X 42W TTT G24q-3 (4 pin) GX24q-3 (4 pin) GX24q-4 (4 pin) (486mm) 191/8” (486mm) 191/8” (486mm) 10” (233mm) (254mm) 10” (254mm) 10” (254mm) (233mm) 93/16” (233mm) 93/16” (233mm) REMODEL 7’’ Horizontal Compact Fluorescent PRODUCTS CODES HOLE CUT BALLAST VOLTAGE F7U13 ø 8” (203mm) Electronic 120/277V F7313 ø 8” (203mm) F7U18 ø 8” (203mm) F7318 ø 8” (203mm) Electronic 347V F7U26 ø 8” (203mm) Electronic 120/277V F7326 ø 8” (203mm) Electronic F7D18 ø 8” (203mm) Electronic Dimming F7D182 ø 8” (203mm) Electronic Dimming 277V F7D26 ø 8” (203mm) Electronic Dimming 120V F7D262 ø 8” (203mm) Electronic Dimming Electronic Electronic 347V 120/277V 347V 120V 277V LENGTH 145/8” WIDTH 91/16” HEIGHT SOURCE BASE (372mm) (231mm) (157mm) 63/16” 2 X 13W DTT G24q-1 (4 pin) 145/8” 91/16” 63/16” (372mm) (231mm) (157mm) 2 X 13W DTT G24q-1 (4 pin) 145/8” 91/16” 63/16” (372mm) (231mm) (157mm) 2 X 18W DTT G24q-2 (4 pin) 145/8” 91/16” 63/16” 2 X 18W DTT G24q-2 (4 pin) (372mm) 145/8” (231mm) 91/16” (157mm) (372mm) (231mm) (157mm) 63/16” 2 X 26W DTT G24q-3 (4 pin) 145/8” 91/16” 63/16” (372mm) (231mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 145/8” 91/16” 63/16” (372mm) (231mm) (157mm) 2 X 18W DTT G24q-1 (4 pin) 145/8” 91/16” 63/16” 2 X 18W DTT G24q-2 (4 pin) (372mm) 145/8” (231mm) (372mm) (231mm) (157mm) 63/16” 2 X 26W DTT G24q-3 (4 pin) 145/8” 91/16” 63/16” 2 X 26W DTT G24q-3 (4 pin) WIDTH HEIGHT SOURCE BASE (254mm) 10” 63/16” (157mm) 2 X 13W DTT G24q-1 (4 pin) 10” 63/16” (372mm) 91/16” (157mm) (231mm) (157mm) CFL HOUSINGS 7” • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings NEW CONSTRUCTION 7’’ Horizontal Compact Fluorescent PRODUCTS CODES HOLE CUT NWF7U13 ø 8” (203mm) NWF7313 ø 8” (203mm) NWF7U18 ø 8” (203mm) Electronic 120/277V NWF7318 ø 8” (203mm) Electronic 347V NWF7U26 ø 8” (203mm) NWF7326 ø 8” (203mm) Electronic NWF7D18 ø 8” (203mm) Electronic Dimming 120V NWF7D182 ø 8” (203mm) Electronic Dimming 277V NWF7D26 ø 8” (203mm) Electronic Dimming NWF7D262 ø 8” (203mm) Electronic Dimming BALLAST Electronic Electronic Electronic VOLTAGE LENGTH 120/277V 191/8” 347V 120/277V 347V 120V 277V (486mm) 191/8” (486mm) (254mm) (157mm) 2 X 13W DTT G24q-1 (4 pin) 191/8” 10” 63/16” 2 X 18W DTT G24q-2 (4 pin) (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” (254mm) 10” (157mm) (254mm) (157mm) 63/16” 2 X 18W DTT G24q-2 (4 pin) (254mm) 10” 63/16” (157mm) 2 X 26W DTT G24q-3 (4 pin) 10” 63/16” (486mm) (254mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 191/8” 10” 63/16” 2 X 18 W DTT G24q-1 (4 pin) (486mm) 191/8” (486mm) 191/8” (486mm) 191/8” (486mm) (254mm) 10” (157mm) (254mm) (157mm) 63/16” 2 X 18W DTT G24q-2 (4 pin) (254mm) 10” 63/16” (157mm) 2 X 26W DTT G24q-3 (4 pin) 10” 63/16” 2 X 26W DTT G24q-3 (4 pin) (254mm) (157mm) Emergency ballast available for New Construction housing with horizontal lamps only (120/277V). Add «EM» to housing code. Ex.: NWF7D182EM • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 571 CFL HOUSINGS 8” REMODEL 8’’ Horizontal Compact Fluorescent PRODUCTS CODES HOLE CUT BALLAST VOLTAGE F8U26 ø 91/4” (235mm) Electronic 120/277V F8326 91/4” ø (235mm) Electronic 347V F8U32 ø (235mm) F8332 ø 91/4” (235mm) Electronic 347V F8U42 ø 91/4” (235mm) Electronic 120/277V F8342 91/4” 91/4” ø (235mm) 120/277V Electronic ø (235mm) Electronic Dimming F8D262 ø 91/4” (235mm) Electronic Dimming 277V F8D32 ø 91/4” (235mm) Electronic Dimming 120V 91/4” ø (235mm) Electronic Dimming 91/4” 120V 277V F8D42 ø (235mm) Electronic Dimming 120V F8D422 ø 91/4” (235mm) Electronic Dimming 277V • Remodel Housings accept 7/8” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 572 347V F8D26 F8D322 91/4” Electronic www.contrastlighting.com LENGTH 151/4” WIDTH 107/16” HEIGHT SOURCE BASE (388mm) (266mm) (157mm) 63/16” 2 X 26W DTT G24q-3 (4 pin) 151/4” 107/16” 63/16” (388mm) (266mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 151/4” 107/16” 63/16” (388mm) (266mm) (157mm) 2 X 32W TTT GX24q-3 (4 pin) 151/4” 107/16” 63/16” 2 X 32W TTT GX24q-3 (4 pin) (388mm) 151/4” (266mm) 107/16” (157mm) (388mm) (266mm) (157mm) 63/16” 2 X 42W TTT GX24q-4 (4 pin) 151/4” 107/16” 63/16” (388mm) (266mm) (157mm) 2 X 42W TTT GX24q-4 (4 pin) 151/4” 107/16” 63/16” (388mm) (266mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 151/4” 107/16” 63/16” 2 X 26W DTT G24q-3 (4 pin) (388mm) 151/4” (266mm) 107/16” (157mm) (388mm) (266mm) (157mm) 63/16” 2 X 32W TTT GX24q-3 (4 pin) 151/4” 107/16” 63/16” (388mm) (266mm) (157mm) 2 X 32W TTT GX24q-3 (4 pin) 151/4” 107/16” 63/16” 2 X 42W TTT GX24q-4 (4 pin) 63/16” 2 X 42W TTT GX24q-4 (4 pin) (388mm) 151/4” (388mm) (266mm) 107/16” (266mm) (157mm) (157mm) NEW CONSTRUCTION 8’’ Horizontal Compact Fluorescent PRODUCTS CODES HOLE CUT BALLAST VOLTAGE NWF8U26 ø 91/4” (235mm) Electronic 120/277V NWF8326 ø 91/4” (235mm) Electronic 347V Electronic 120/277V NWF8U32 91/4” ø (235mm) NWF8332 ø (235mm) NWF8U42 ø 91/4” (235mm) Electronic 120/277V NWF8342 ø 91/4” (235mm) Electronic 347V NWF8D26 91/4” ø (235mm) Electronic 91/4” Electronic Dimming 91/4” 347V 120V NWF8D262 ø (235mm) Electronic Dimming NWF8D32 ø 91/4” (235mm) Electronic Dimming 120V NWF8D322 ø 91/4” (235mm) Electronic Dimming 277V NWF8D42 NWF8D422 91/4” ø (235mm) Electronic Dimming 91/4” Electronic Dimming ø (235mm) 277V 120V 277V LENGTH 191/8” (486mm) 191/8” (486mm) 191/8” WIDTH 141/8” (359mm) 141/8” (359mm) 141/8” HEIGHT SOURCE BASE 63/16” 2 X 26W DTT G24q-3 (4 pin) 63/16” 2 X 26W DTT G24q-3 (4 pin) (157mm) (157mm) (486mm) (359mm) (157mm) 63/16” 2 X 32W TTT GX24q-3 (4 pin) 191/8” 141/8” 63/16” (486mm) (359mm) (157mm) 2 X 32W TTT GX24q-3 (4 pin) 191/8” 141/8” 63/16” 2 X 42W TTT GX24q-4 (4 pin) (486mm) 191/8” (359mm) 141/8” (157mm) (486mm) (359mm) (157mm) 63/16” 2 X 42W TTT GX24q-4 (4 pin) 191/8” 141/8” 63/16” (486mm) (359mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 191/8” 141/8” 63/16” (486mm) (359mm) (157mm) 2 X 26W DTT G24q-3 (4 pin) 191/8” 141/8” 63/16” 2 X 32W TTT GX24q-3 (4 pin) (486mm) 191/8” (359mm) 141/8” (157mm) (486mm) (359mm) (157mm) 63/16” 2 X 32W TTT GX24q-3 (4 pin) 191/8” 141/8” 63/16” 2 X 42W TTT GX24q-4 (4 pin) 2 X 42W TTT GX24q-4 (4 pin) (486mm) (359mm) (157mm) 191/8” 141/8” 63/16” (486mm) (359mm) (157mm) CFL HOUSINGS 8” Emergency ballast available for New Construction housing with horizontal lamps only (120/277V). Add «EM» to housing code. Ex.: NWF8D262EM • New Construction Housings accept 1 1/2” ceiling thickness. • Below Ceiling Accessibility • Thermally Protected Housings 573 Parts and Accessories Compact Fluorescent 4 6 7 8” , , & Parts & Accessories Shower Lenses For compact fluorescent 4” shower trims. LENSES Lenses for compact fluorescent 4” (110mm) Clear / convex 312648 Frosted / convex 312649 Clear 103099 *Frosted 103100 Frosted / clear center 103101 *Frosted lens is factory installed. The other lenses are sold separately. Marine Grade Treatment Available for Contrast trims. This treatment is offered with our trim collection of finishes -01, -02, -05, -06, -11, -14 and -15. Unless otherwise indicated, all trim series are for interior use only. For exterior use, «Marine Grade» treatment is recommended. This procedure increases rust resistance up to 5 times more than the untreated galvanized steel. Furtermore, the high temperature powder coated paint process provides a durable finish. The «Marine Grade» treatment is recommended for very high level humidity locations and is particularly efficient in high salinity areas such as coastal regions. It may be used for outdoors such as soffits and porches, or for indoors, in high humidity or wet areas such as spas, saunas, showers, pool, etc. This treatment is offered with a Contrast limited warranty of two (2) years. 576 www.contrastlighting.com Parts & Accessories Ballast For Fluorescent. Electronic Ballast CODE 100744 100746 100742 100743 100745 100750 DESCRIPTION 120-277V 1 X 13W BES Electronic 120-277V 2 X 13W BES Electronic 120-277V 1 X 18W BES Electronic 120-277V 2 X 18W BES Electronic 120-277V 1 X 26/32/42W BES Electronic 120-277V 2 X 26W BES Electronic 347V 1 X 13W BES Electronic 347V 2 X 13W BES Electronic 347V 1 X 18W BES Electronic 347V 2 X 18W BES Electronic 347V 1 X 26/32/42W BES Electronic 347V 2 X 26W BES Electronic 100749 120-277V 2 X 26/32/42W BES Electronic 100747 347V 2 X 26/32/42W BES Electronic CODE DESCRIPTION 101278 DIM 120V 1 X 18W BES DIM 277V 101289 Electronic Dimmable 101279 DIM 120V 2 X 18W BES DIM 277V 101281 Electronic Dimmable 101286 DIM 120V 2 X 26W BES DIM 277V 101283 Electronic Dimmable 101138 DIM 120V 2 X 26W BES 1 X 26/32/42W BES DIM 277V 101280 1 X 26/32/42W BES Electronic Dimmable 101287 DIM 120V 2 X 32/42W BES DIM 277V 101284 Electronic Dimmable CODE DESCRIPTION 101308 Hi Power Factor 120V 13W CODE DESCRIPTION 306997 120/277V 60HZ Dimmable Ballast Magnetic Ballast Magnetic Emergency Ballast Electronic 577 Energy Star Energy Star R Qualified Fixtures 4” Housings F2000U13 F2675RU13 F2000LU18 F2575RU13 F2000U18 F2675RU18 F2000LU26 F2575RU18 F2000U26 F2675RU26 NWF2000LU18 F2575RU26 NWF2000U13 F2675RU32 NWF2000LU26 NWF2575RU13 NWF2000U18 NWF2675RU13 NWF2000LD26 NWF2575RU18 NWF2000U26 NWF2675RU18 NWF2575RU26 NWF2000D26 NWF2675RU26 NWF2575RD26 NWF2675RD26 NWF2675RU32 combined with combined with combined with NWF2675RD32 Trims A2000V FB2675 A2400S A2000VL FC2675 A2401S A2000VLS A2450S A2000VS A2451S A2010V F2450VT A2010VL A2010VLS A2010VS 578 www.contrastlighting.com Energy Star 6” Housings 7” Housings F6HD26S F6VU13 F6HD32S F6VU18 F7U13 F7U18 F6HU13 F6VU26 F7U26 F6HU13S F6VU32 NWF7U13 F6HU18 F6VU42 NWF7U18 F6HU18S NWF6VU13 NWF7U26 F6HU26 NWF6VU18 F6HU26S NWF6VU42 8” Housings F8U26 NWF8U26 Energy Star Qualified Fixtures F6HU32S NWF6HD26S NWF6HD32S NWF6HU13 NWF6HU13S NWF6HU26S NWF6HU32S Trims combined with NWF6HU26 combined with NWF6HU18S combined with combined with NWF6HU18 Trims Trims FR6HO FR6VO FR7C FR8C FR6HOLA FR6VOLA FR7O FR8O FR6HOLB FR6VOLB FR7OLA FR8OLA FR6HOM FR6VOW120 FR7OLB FR8OLB FR6HOW120 FR6VOW90 FR7OM FR8OM FR6HOW90 FR6VOW90D FR7T FR8T FR6HOMW120 FR6VOM FR6HOMW90 FR6VOMW120 FR6VOMW90 FR6VOMW90D 579