Fluorescent - Contrast Lighting

advertisement
RECESSED LIGHTING
FLUORESCENT
4”
452
454
456
458
460
A2000V
A2010V
A2000VL
A2010VL
A2000VLS
462
464
466
468
470
A2010VLS
A2000VS
A2010VS
A2400S
A2450S
472
474
476
478
480
B2675
F2450VT
F2575R
F2575RU
FB2675
486-488
490-492
494-496
498-500
502-504
FR6HO
FR6HOLA
FR6HOLB
FR6HOW90
FR6HOW120
506-512
514
516-518
520-522
524-526
FR6VO
FR6VOG
FR6VOLA
FR6VOLB
FR6VOW90
528-530
532-534
FR6VOW90D
FR6VOW120
538
540
542
544
546
FR7C
FR7O
FR7OLA
FR7OLB
FR7T
550
552
554
556
558
FR8C
FR8O
FR8OLA
FR8OLB
FR8T
482
FC2675
6”
7”
8”
10
www.contrastlighting.com
Compact Fluorescent
Energy Efficient Lighting
4”
450
www.contrastlighting.com
fluorescent
FR8C-11
See page 550 for more details
451
FLUO
4”
A2000V
Downlight
A2000V-02
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000V)
Cobalt Blue (A2010V).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
211/16”
68mm
111/16”
43mm
Hole Cut : 41/4”
21/2”
63mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2000V-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code.Ex.: A2000V-01MG
452
www.contrastlighting.com
A2000V
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF2000D18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: NWF2000D182
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
120˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
30
60°
50
70
45°
90
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.4
1.3
0.9
0.6
0.4
0.3
0.3
0.2
DIA
5.7’
7.6’
9.5’
11.3’
13.2’
15.1’
17.0’
18.9’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 57.7%
Spacing Criteria
1.7
Certificate
S0604261
80
50 30
67 67
47 42
35 29
28 22
23 17
19 14
50
50 30
60 60
42 38
31 27
25 20
20 16
17 13
30
50 30
56 56
39 36
29 25
23 19
19 15
16 12
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
55
75
45°
100
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.6
1.4
0.9
0.6
0.5
0.4
0.3
0.2
DIA
2.7’
3.7’
4.6’
5.5’
6.4’
7.3’
8.2’
9.2
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 45.3%
Spacing Criteria
1.6
Certificate
S0512014
80
50 30
53 53
38 34
29 24
23 18
19 15
16 12
50
50 30
47 47
34 31
26 22
21 17
17 14
14 11
30
50 30
44 44
32 29
24 21
19 16
16 13
14 11
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
50
60°
75
100
45°
125
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.6
2.0
1.3
0.9
0.7
0.5
0.4
0.3
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 40.2%
Spacing Criteria
1.4
Certificate
S0512011
80
50 30
47 47
34 31
26 23
21 17
17 14
15 11
50
50 30
43 43
31 29
24 21
19 16
16 13
14 11
30
50 30
40 40
29 27
23 20
18 16
15 13
13 10
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
40
75°
80
60°
120
160
45°
200
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.5
3.1
2.0
1.4
1.0
0.8
0.6
0.5
DIA
2.1’
2.9’
3.6’
4.3’
5.0’
5.7’
6.4’
7.1’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 46.7%
Spacing Criteria
1.5
Certificate
S0512052
80
50 30
54 54
39 36
30 26
24 19
20 15
16 13
50
50 30
49 49
35 33
27 24
22 18
18 15
15 12
30
50 30
46 46
33 31
25 22
21 17
17 14
14 12
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
453
FLUO
4”
A2010V
Downlight
A2010V-02
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000V)
Cobalt Blue (A2010V).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
211/16”
68mm
111/16”
43mm
Hole Cut : 41/4”
21/2”
63mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 18W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2010V-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2010V-14MG
454
www.contrastlighting.com
A2010V
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2000D26
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: F2000D262
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
120˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
0
75°
10
60°
20
30
45°
40
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.0
0.6
0.4
0.3
0.2
0.1
0.1
0.1
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 12.1%
Spacing Criteria
1.8
Certificate
S0604262
80
50 30
14 14
11 11
09 08
07 06
06 05
05 04
50
50 30
13 13
11 10
08 08
07 06
06 05
05 04
30
50 30
13 13
10 10
08 07
07 06
06 05
05 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
15
60°
25
30
45°
40
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.1
0.6
0.4
0.3
0.2
0.2
0.1
0.1
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 7.7%
Spacing Criteria
1.5
Certificate
S0512051
80
50 30
09 09
08 07
06 06
05 05
05 04
04 03
50
50 30
09 09
07 07
06 06
05 05
04 04
04 03
30
50 30
08 08
07 07
06 06
05 05
04 04
04 03
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
25
60°
40
55
45°
70
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.9
1.0
0.7
0.5
0.3
0.3
0.1
0.1
DIA
0.8’
1.1’
1.4’
1.7’
2.0’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 7.9%
Spacing Criteria
1.2
Certificate
S0512013
80
50 30
09 09
08 08
07 06
06 05
05 04
04 04
50
50 30
09 09
08 07
07 06
06 05
05 04
04 04
30
50 30
08 08
07 07
06 06
05 05
05 04
04 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
60
80
45°
100
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.7
1.5
1.0
0.7
0.5
0.4
0.3
0.2
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 9.4%
Spacing Criteria
1.4
Certificate
S0512054
80
50 30
11 11
09 09
08 07
07 06
06 05
05 04
50
50 30
10 10
09 09
07 07
06 06
05 05
05 04
30
50 30
10 10
09 08
07 07
06 06
05 05
05 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
455
FLUO
4”
A2000VL
Downlight
A2000VL-04BR
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VL)
Cobalt Blue (A2010VL).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
215/16”
74mm
115/16”
49mm
Hole Cut : 41/4”
23/16”
55mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2000VL-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2000VL-11MG
456
www.contrastlighting.com
A2000VL
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF2000D18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: NWF2000D182
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
120˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
30
60°
50
70
45°
90
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.4
1.3
0.9
0.6
0.4
0.3
0.3
0.2
DIA
5.7’
7.6’
9.5’
11.3’
13.2’
15.1’
17.0’
18.9’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 57.7%
Spacing Criteria
1.7
Certificate
S0604261
80
50 30
67 67
47 42
35 29
28 22
23 17
19 14
50
50 30
60 60
42 38
31 27
25 20
20 16
17 13
30
50 30
56 56
39 36
29 25
23 19
19 15
16 12
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
55
75
45°
100
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.6
1.4
0.9
0.6
0.5
0.4
0.3
0.2
DIA
2.7’
3.7’
4.6’
5.5’
6.4’
7.3’
8.2’
9.2
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 45.3%
Spacing Criteria
1.6
Certificate
S0512014
80
50 30
53 53
38 34
29 24
23 18
19 15
16 12
50
50 30
47 47
34 31
26 22
21 17
17 14
14 11
30
50 30
44 44
32 29
24 21
19 16
16 13
14 11
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
50
60°
75
100
45°
125
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.6
2.0
1.3
0.9
0.7
0.5
0.4
0.3
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 40.2%
Spacing Criteria
1.4
Certificate
S0512011
80
50 30
47 47
34 31
26 23
21 17
17 14
15 11
50
50 30
43 43
31 29
24 21
19 16
16 13
14 11
30
50 30
40 40
29 27
23 20
18 16
15 13
13 10
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
40
75°
80
60°
120
160
45°
200
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.5
3.1
2.0
1.4
1.0
0.8
0.6
0.5
DIA
2.1’
2.9’
3.6’
4.3’
5.0’
5.7’
6.4’
7.1’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 46.7%
Spacing Criteria
1.5
Certificate
S0512052
80
50 30
54 54
39 36
30 26
24 19
20 15
16 13
50
50 30
49 49
35 33
27 24
22 18
18 15
15 12
30
50 30
46 46
33 31
25 22
21 17
17 14
14 12
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
457
FLUO
4”
A2010VL
Downlight
A2010VL-08
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VL)
Cobalt Blue (A2010VL).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
215/16”
74mm
115/16”
49mm
Hole Cut : 41/4”
23/16”
55mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2010VL-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2010VL-11MG
458
www.contrastlighting.com
A2010VL
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: ISF2000D18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: ISF2000D182
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
Mounting Bars
• Take up to 7/8” thick ceilings
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. Trims
• Lockable integral T-Bar tabs. May be hung Plated or painted steel
from trusses or suspended ceilings.
Efficient CFL Housings
Housing Features
Socket & Lamp Bases
• Galvanized steel
High temperature-rated
• Below ceiling accessible
120˚C instead of 90˚C
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
00
75°
10
60°
20
30
45°
40
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.0
0.6
0.4
0.3
0.2
0.1
0.1
0.1
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 12.1%
Spacing Criteria
1.8
Certificate
S0604262
80
50 30
14 14
11 11
09 08
07 06
06 05
05 04
50
50 30
13 13
11 10
08 08
07 06
06 05
05 04
30
50 30
13 13
10 10
08 07
07 06
06 05
05 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
15
60°
25
30
45°
40
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.1
0.6
0.4
0.3
0.2
0.2
0.1
0.1
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 7.7%
Spacing Criteria
1.5
Certificate
S0512051
80
50 30
09 09
08 07
06 06
05 05
05 04
04 03
50
50 30
09 09
07 07
06 06
05 05
04 04
04 03
30
50 30
08 08
07 07
06 06
05 05
04 04
04 03
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
25
60°
40
55
45°
70
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.9
1.0
0.7
0.5
0.3
0.3
0.1
0.1
DIA
0.8’
1.1’
1.4’
1.7’
2.2’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 7.9%
Spacing Criteria
1.2
Certificate
S0512013
80
50 30
09 09
08 08
07 06
06 05
05 04
04 04
50
50 30
09 09
08 07
07 06
06 05
05 04
04 04
30
50 30
08 08
07 07
06 06
05 05
05 04
04 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
60
80
45°
100
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.7
1.5
1.0
0.7
0.5
0.4
0.3
0.2
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 9.4%
Spacing Criteria
1.4
Certificate
S0512054
80
50 30
11 11
09 09
08 07
07 06
06 05
05 04
50
50 30
10 10
09 09
07 07
06 06
05 05
05 04
30
50 30
10 10
09 08
07 07
06 06
05 05
05 04
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
459
FLUO
4”
A2000VLS
Shower
A2000VLS-04BR
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VLS)
Cobalt Blue (A2010VLS).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
215/16”
74mm
115/16”
49mm
Hole Cut : 41/4”
23/16”
55mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2000VLS-05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2000VLS-05MG
460
www.contrastlighting.com
A2000VLS
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: ISF2000D18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: ISF2000D182
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
130˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
25
60°
40
55
45°
70
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.0
1.1
0.7
0.5
0.4
0.3
0.2
0.2
LUMINAIRE
DIA
11.4’
15.2’
19.1’
22.9’
26.7’
30.5’
34.3’
38.1’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
Lamp Type
Initial Lumens
COEFFICIENT OF UTILIZATION - %
Input Watts
13W Quad, 2pin
780
120V
16W
Operating AMPS
0.13A
Luminaire Efficiency 51.0%
Spacing Criteria
1.5
Certificate
S0604263
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
59 59
41 37
31 26
24 19
20 15
16 12
50
50 30
53 53
36 33
27 23
21 17
18 14
15 11
30
50 30
49 49
33 28
25 19
20 14
16 11
14 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
25
60°
40
55
45°
75
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.9
1.1
0.7
0.5
0.4
0.3
0.2
0.2
DIA
3.7’
5.0’
6.2’
7.5’
8.7’
10.0’
11.2’
12.4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 39.6%
Spacing Criteria
1.4
Certificate
S0512015
80
50 30
46 46
32 29
24 20
19 15
16 12
13 10
50
50 30
41 41
29 26
22 19
17 14
14 11
12 09
30
50 30
38 38
26 24
20 17
16 13
13 11
11 09
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
60
80
45°
100
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.9
1.6
1.0
0.7
0.5
0.4
0.3
0.3
DIA
2.7’
3.7’
4.6’
5.5’
6.4’
7.3’
8.2’
9.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 39.7%
Spacing Criteria
1.4
Certificate
S0512012
80
50 30
46 46
33 30
25 21
20 16
16 12
13 10
50
50 30
41 41
29 27
22 19
18 15
15 12
12 10
30
50 30
39 39
27 25
21 18
17 14
14 11
12 09
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
50
60°
80
100
45°
130
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.6
2.0
1.3
0.9
0.7
0.5
0.4
0.3
DIA
3.7’
5.0’
6.2’
7.5’
8.7’
10.0’
11.2’
12.4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 34.9%
Spacing Criteria
1.4
Certificate
S0512053
80
50 30
41 41
29 26
22 18
17 14
14 11
12 09
50
50 30
36 36
26 23
19 17
15 13
13 10
11 08
30
50 30
34 34
24 22
18 16
14 12
12 10
10 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
461
FLUO
4”
A2010VLS
Shower
A2010VLS-12BR
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VLS)
Cobalt Blue (A2010VLS).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
215/16”
74mm
115/16”
49mm
Hole Cut : 41/4”
23/16”
55mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2010VLS-06
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2010VLS-11MG
462
www.contrastlighting.com
A2010VLS
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2000D26
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: F2000D262
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
Mounting Bars
• Take up to 7/8” thick ceilings
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. Trims
• Lockable integral T-Bar tabs. May be hung Plated or painted steel
from trusses or suspended ceilings.
Efficient CFL Housings
Housing Features
Socket & Lamp Bases
• Galvanized steel
High temperature-rated
• Below ceiling accessible
120˚C instead of 90˚C
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
LUMINAIRE
DIA
11.4’
17.1’
22.8’
28.5’
34.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
NOTES
13W Quad, 2pin
780
120V
16W
0.13A
13W Elect. DTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
LUMINAIRE
DIA
9.5’
14.2’
19.0’
23.8’
28.5’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
NOTES
13W Quad, 4pin
900
120V 277V 347V
18W
18W 18W
0.15A 0.07A 0.06A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Elect. TTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
NOTES
LUMINAIRE
DIA
9.5’
14.2’
19.0’
23.8’
28.5’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
18W Triple Tube, 4pin
1200
120V 277V 347V
19W
19W 21W
0.16A 0.07A 0.06A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Elect. TTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.2
0.1
0.1
0.1
0.1
NOTES
LUMINAIRE
DIA
8’
12’
16’
20’
24’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
26W Triple Tube, 4pin
1800
120V 277V 347V
28W
28W 31W
0.25A 0.11A 0.09A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
463
FLUO
4”
A2000VS
Shower
A2000VS-04BR
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VS)
Cobalt Blue (A2010VS).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
211/16”
68mm
111/16”
43mm
Hole Cut : 41/4”
21/2”
63mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2000VS-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: R3470-14MG
464
www.contrastlighting.com
A2000VS
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2000D26
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: F2000D262
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
120˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000U13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000U13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
25
60°
40
55
45°
70
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.0
1.1
0.7
0.5
0.4
0.3
0.2
0.2
DIA
11.4’
15.2’
19.1’
22.9’
26.7’
30.5’
34.3’
38.1’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 51.0%
Spacing Criteria
1.5
Certificate
S0604263
80
50 30
59 59
41 37
31 26
24 19
20 15
16 12
50
50 30
53 53
36 33
27 23
21 17
18 14
15 11
30
50 30
49 49
33 28
25 19
20 14
16 11
14 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
25
60°
40
55
45°
75
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.9
1.1
0.7
0.5
0.4
0.3
0.2
0.2
DIA
3.7’
5.0’
6.2’
7.5’
8.7’
10.0’
11.2’
12.4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 39.6%
Spacing Criteria
1.4
Certificate
S0512015
80
50 30
46 46
32 29
24 20
19 15
16 12
13 10
50
50 30
41 41
29 26
22 19
17 14
14 11
12 09
30
50 30
38 38
26 24
20 17
16 13
13 11
11 09
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
40
60°
60
80
45°
100
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.9
1.6
1.0
0.7
0.5
0.4
0.3
0.3
DIA
2.7’
3.7’
4.6’
5.5’
6.4’
7.3’
8.2’
9.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 39.7%
Spacing Criteria
1.4
Certificate
S0512012
80
50 30
46 46
33 30
25 21
20 16
16 12
13 10
50
50 30
41 41
29 27
22 19
18 15
15 12
12 10
30
50 30
39 39
27 25
21 18
17 14
14 11
12 09
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
50
60°
80
100
45°
130
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.6
2.0
1.3
0.9
0.7
0.5
0.4
0.3
DIA
3.7’
5.0’
6.2’
7.5’
8.7’
10.0’
11.2’
12.4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 34.9%
Spacing Criteria
1.4
Certificate
S0512053
80
50 30
41 41
29 26
22 18
17 14
14 11
12 09
50
50 30
36 36
26 23
19 17
15 13
13 10
11 08
30
50 30
34 34
24 22
18 16
14 12
12 10
10 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
465
FLUO
4”
A2010VS
Shower
A2010VS-12BR
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Glass
The glass is available in 2 colors.
Natural (A2000VS)
Cobalt Blue (A2010VS).
Housings Specifications
New Construction (NW)
Code
NWF2000U13
NWF2000U18
NWF2000U26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
6”
6”
6”
211/16”
68mm
111/16”
43mm
Hole Cut : 41/4”
21/2”
63mm
Remodel
Code
F2000
F2000U13
F2000U18
F2000U26
Lamp
1 X 13W
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
TTT
TTT
Base
GX23-2
G24q-1
GX24q-2
GX24q-3
(2
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120V
120-277V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
Electronic
L
W
13”
139/16”
139/16”
139/16”
X
X
X
X
Hole Cut :
H
51/8”
51/8”
51/8”
51/8”
X
X
X
X
4”
102mm
4”
61/16”
61/16”
61/16”
ø 53/16”
132mm
41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000
1
ISF2000U13
1
ISF2000U18
Lamp
1 X 13W
1 X 13W
1 X 26W
DTT
DTT
TTT
Base
GX23-2 (2 pin)
G24q-1 (4 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/16”
193/8”
193/8”
X
X
X
H
81/8”
10”
10”
X
X
X
ø 21/8”
54mm
71/2”
61/16”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2010VS-04
For exterior use Wet and Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2010VS-01MG
466
www.contrastlighting.com
A2010VS
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF2000D18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: NWF2000D182
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Trims
from trusses or suspended ceilings.
Plated or painted steel
Housing Features
Efficient CFL Housings
• Galvanized steel
Socket & Lamp Bases
• Below ceiling accessible
High temperature-rated
• Keyhole on socket assembly for
120˚C instead of 90˚C
easier installation
• See specs in Housing Section
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000U13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000U13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Magn. DTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
LUMINAIRE
DIA
11.4’
17.1’
22.8’
28.5’
34.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
NOTES
13W Quad, 2pin
780
120V
16W
0.13A
13W Elect. DTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
LUMINAIRE
DIA
9.5’
14.2’
19.0’
23.8’
28.5’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
NOTES
13W Quad, 4pin
900
120V 277V 347V
18W
18W 18W
0.15A 0.07A 0.06A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Elect. TTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
NOTES
LUMINAIRE
DIA
9.5’
14.2’
19.0’
23.8’
28.5’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
18W Triple Tube, 4pin
1200
120V 277V 347V
19W
19W 21W
0.16A 0.07A 0.06A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Elect. TTT
CONE OF LIGHT
Distance
04’
06’
08’
10’
12’
FC
0.1
0.1
0.1
0.0
0.0
NOTES
LUMINAIRE
DIA
8’
12’
16’
20’
24’
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
26W Triple Tube, 4pin
1800
120V 277V 347V
28W
28W 31W
0.25A 0.11A 0.09A
Beam Edge defined as
50% of Maximum Nadir
Candlepower
467
FLUO
4”
A2400S
Shower
A2400S-01
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Lenses
Standard: UV frosted lens (110mm). Ex.: A2400S. Also Available:
Frosted convex:
A2401S
Clear convex:
A2402S
Clear:
A2403S
Frosted with clear center:
A2404S
See page 576 for more details.
2
STANDARD
3
1
4
Housings Specifications
7/16”
11mm
New Construction (NW)
Code
NW2000LF
NWF2000LU18
NWF2000LU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
13/8”
35mm
71/4”
71/4”
71/4”
Hole Cut : 41/4”
Remodel
Code
F2000L
F2000LU18
F2000LU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/4”
1311/16”
1311/16”
X
X
X
H
51/8”
51/8”
51/8”
X
X
X
71/4”
71/4”
71/4”
ø 53/16”
132mm
Hole Cut : 41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000L
1
ISF2000LU18
Lamp
1 X 13W
1 X 18W
DTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
Ballast
L
HPF Magn. 153/16”
Electronic 193/8”
W
H
X 81/8”
X 71/2”
X
10”
X
ø 41/16”
103mm
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2400S-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2400S-01MG
468
www.contrastlighting.com
A2400S
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF2000LD18
• 277V: For dimming capability, change «U» • Keyhole on socket assembly for
to «D» and add «2» at the end of the housing easier installation
code of 18W to 42W. Ex: NWF2000LD182
• See specs in Housing Section
Emergency Ballast
Available for New Construction housing
(NW) with Electronic Ballast (120-277V).
Add «EM» to housing code.
Ex: NWF2000LU26EM
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Trims
Plated or painted steel
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000LU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000LU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
30
60°
45
60
45°
75
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
2.0
1.1
0.7
0.5
0.4
0.3
0.2
0.2
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 26.9%
Spacing Criteria
1.4
Certificate
S0608073R1
80
50 30
32 32
25 23
19 17
16 13
13 11
11 09
50
50 30
30 30
23 22
18 17
15 13
12 10
11 09
30
50 30
27 27
22 21
17 16
14 12
12 10
10 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
50
60°
75
100
45°
125
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.5
2.0
1.3
0.9
0.6
0.5
0.4
0.3
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 29.5%
Spacing Criteria
1.4
Certificate
S0512081
80
50 30
35 35
27 25
21 19
17 15
14 12
12 10
50
50 30
33 33
26 24
20 18
16 14
14 12
12 10
30
50 30
31 31
25 24
20 18
16 14
13 11
11 10
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
35
75°
75
60°
115
150
45°
190
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.1
2.9
1.8
1.3
0.9
0.7
0.6
0.5
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 30.1%
Spacing Criteria
1.4
Certificate
S0512072
80
50 30
36 36
28 26
22 19
17 15
14 12
12 10
50
50 30
33 33
26 25
20 18
17 14
14 12
12 10
30
50 30
32 32
25 24
20 18
16 14
13 11
11 09
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
469
FLUO
4”
A2450S
Shower
A2450S-08
Vertical
Wet location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Lenses
Standard: UV frosted lens (110mm). Ex.: A2450S. Also Available:
Frosted convex:
A2451S
Clear convex:
A2452S
Clear:
A2453S
Frosted with clear center:
A2454S
See page 576 for more details.
2
STANDARD
3
1
4
13/16”
30mm
Housings Specifications
1/8”
3mm
New Construction (NW)
Code
NW2000LF
NWF2000LU18
NWF2000LU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
71/4”
71/4”
71/4”
Hole Cut : 41/4”
Remodel
Code
F2000L
F2000LU18
F2000LU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120V
120-277V
120-277V
Ballast
HPF Magn.
Electronic
Electronic
L
W
153/4”
1311/16”
1311/16”
X
X
X
H
51/8”
51/8”
51/8”
X
X
X
ø 3”
76mm
ø 47/8”
124mm
71/4”
71/4”
71/4”
Hole Cut : 41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000L
1
ISF2000LU18
Lamp
1 X 13W
1 X 18W
DTT
TTT
Base
GX23-2 (2 pin)
GX24q-2 (4 pin)
Volts
120V
120-277V
Ballast
L
HPF Magn. 153/16”
Electronic 193/8”
W
X
X
H
81/8”
10”
X
X
71/2”
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: A2450S-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: A2450S-11MG
470
www.contrastlighting.com
A2450S
Vertical
Technical Specifications
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2000LD18
• 277V: For dimming capability, change «U» • Keyhole on socket assembly for
to «D» and add «2» at the end of the housing easier installation
code of 18W to 42W. Ex: F2000LD182
• See specs in Housing Section
Emergency Ballast
Available for New Construction housing
(NW) with Electronic Ballast(120-277V).
Add «EM» to housing code.
Ex: NWF2000LU26EM
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Trims
Plated or painted steel
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000LU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000LU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Photometric Data
13W Magn. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
13
75°
25
60°
38
50
45°
63
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
1.7
1.0
0.6
0.4
0.3
0.2
0.2
0.2
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 23.8%
Spacing Criteria
1.4
Certificate
S0608071R1
80
50 30
28 28
22 20
17 15
14 11
11 09
10 08
50
50 30
27 27
20 19
16 14
13 11
11 09
09 07
30
50 30
24 24
19 18
15 14
12 11
10 09
09 07
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
20
75°
45
60°
65
90
45°
110
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.0
1.7
1.1
0.8
0.6
0.4
0.3
0.3
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 26%
Spacing Criteria
1.4
Certificate
S0512074
80
50 30
31 31
24 22
19 16
15 13
13 10
11 09
50
50 30
29 29
23 21
18 16
14 12
12 10
10 08
30
50 30
28 28
22 21
17 16
14 12
12 10
10 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
30
75°
65
60°
100
130
45°
160
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
4.4
2.5
1.6
1.1
0.8
0.6
0.5
0.4
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 26.7%
Spacing Criteria
1.4
Certificate
S0512061
80
50 30
32 32
24 23
19 17
15 13
13 10
11 09
50
50 30
30 30
23 22
18 16
15 13
12 10
10 08
30
50 30
28 28
22 21
17 16
14 12
12 10
10 08
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
471
FLUO
4”
B2675
Downlight
B2675-08
Vertical
modèle
Damp location
Compact fluorescent: 1 X CFQ-13W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Champagne finish: Add «CH» after the housing code. Ex.: F2675RCH
Housings Specifications
5/8”
16mm
New Construction (NW)
Code
NW2675F
Lamp
1 X 13W
DTT
Base
GX23-2
(2 pin)
Volts
120V
Ballast
L
HPF Magn. 1411/16”
W
X
17/8”
48mm
H
10”
X
6”
X
6”
X
71/2”
Hole Cut : 45/8”
Remodel
Code
F2675R
Lamp
1 X 13W
DTT
Base
GX23-2
(2 pin)
Volts
120V
Ballast
L
HPF Magn. 143/4”
W
X
H
59/16”
ø 6”
152mm
Hole Cut : 45/8”
Insulated Ceiling (IC)1
Code
1
ISF2675R
Lamp
1 X 13W
DTT
Base
GX23-2
(2 pin)
Volts
120V
Ballast
L
HPF Magn. 153/16”
W
X
H
81/8
ø 37/8”
98mm
Hole Cut : 45/8”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: B2675-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: B2675-11MG
472
www.contrastlighting.com
B2675
Vertical
Technical Specifications
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Trims
Plated or painted steel
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent champagne
finish. Add «CH» to housing code.
Ex: F2575RCH
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2575RW
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2575RP
4”
FLUO
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Photometric Data
13W Magn. DTT - Clear Reflector
CANDLEPOWER DISTRIBUTION
Candelas
90°
10
75°
40
60°
70
100
45°
130
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
3.7
2.1
1.3
0.9
0.7
0.5
0.4
0.3
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 49.1%
Spacing Criteria
2.0
Certificate
S0605102
80
50 30
58 58
45 42
35 31
28 23
23 18
19 15
50
50 30
55 55
43 40
33 30
27 23
22 18
18 15
30
50 30
52 52
41 39
32 29
26 22
21 18
18 14
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Magn. DTT - Champagne Reflector
CANDLEPOWER DISTRIBUTION
Candelas
90°
25
75°
45
60°
65
85
45°
105
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
DIA
3.0
1.7’
1.7
2.3’
1.1
2.9’
0.8
3.5’
0.6
4.0’
0.4
4.6’
0.3
5.2’
0.3
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 40.6%
Spacing Criteria
2.0
Certificate
S0605103
80
50 30
48 48
38 35
29 26
23 19
19 15
16 12
50
50 30
45 45
35 33
28 25
22 19
18 15
15 12
30
50 30
43 43
34 32
27 24
21 19
17 15
15 12
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
473
FLUO
4”
F2450VT
Downlight
F2450VT-04BR-WFF04
Damp location
Compact fluorescent: 1 X CFQ-18W
1 X CFQ-26W
1 X CFTR-18W 1 X CFTR-26W 1 X CFTR-32W
** Lamps must meet ANSI requirements.**
3 5/16"
84mm
1/8"
3mm
Glass Tube Colors
Available in 7 different colors.
Ex.: F2450VT-01-NFF07
COLORS
Eggplant
Blue
Green
Amber
Natural
Red
White
CODES
-A
-B
-G
-M
-N
-R
-W
3"
4"
Glass Tube Textures
5"
Available in 2 different textures.
Ex.: F2450VT-01-NFF07
TEXTURES
CODES
3" à 7"
76 à 178mm
6"
Clear
Frosted int./ext.
C
FF
7"
3"
76mm
4 7/8"
124mm
Glass Tube Lengths
Available in 5 different lengths.
Ex.: F2450VT-01-NFF07
LENGTHS
3” (76mm)
4” (102mm)
5” (127mm)
6” (152mm)
7” (178mm)
03
04
05
06
07
CODES
3"
76mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: F2450VT-02-NFF06
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F2450VT-11MG-RC03
474
www.contrastlighting.com
F2450VT
Vertical
Technical Specifications
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF2000LU26EM
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Dimming Capability
• 120V: For dimming capability, change «U» Housing Features
to «D» in codes of housing of 18W to 42W. • Galvanized steel
Ex.: F2000LD18
• Below ceiling accessible
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F2000LD182
F2450VT
Trim codification
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2000LU18W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2000LU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Specs and codification
F2450VT-04BR-WFF03
MODEL
TRIM FINISH
GLASS COLOR
GLASS TEXTURE
GLASS LENGTH
F2450VT
-04BR
-W
FF
03
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-A
-B
-G
-M
-N
-R
-W
Eggplant
Cobalt Blue
Green
Amber
Naturel
Red
White
FF
Frosted int./ext.
C
Clear
03
04
05
06
07
3”
4”
5”
6”
7”
of
of
of
of
of
the
the
the
the
the
trim
trim
trim
trim
trim
Housings Specifications
New Construction (NW)
Code
NWF2000LU18
NWF2000LU18
NWF2000LU32
NWF2000LU32
Lamp
1 X 18W
1 X 18W
1 X 26W
1 X 26/32W
DTT
TTT
DTT
TTT
Base
G24q-2
GX24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
1411/16”
1411/16”
1411/16”
1411/16”
W
X
X
X
X
10”
10”
10”
10”
H
X
X
X
X
71/4”
71/4”
71/4”
71/4”
Hole Cut : 41/4”
Remodel
Code
F2000LU18
F2000LU32
F2000LU32
Lamp
1 X 18W
TTT
1 X 26W
DTT
1 X 26/32W TTT
Base
GX24q-2 (4 pin)
G24q-3 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
1311/16”
1311/16”
1311/16”
W
X
X
X
51/8”
51/8”
51/8”
H
X
X
X
71/4”
71/4”
71/4”
Hole Cut : 41/4”
Insulated Ceiling (IC)1
Code
1
ISF2000LU18
Lamp
1 X 18W
TTT
Base
GX24q-2 (4 pin)
Volts
120-277V
Ballast
Electronic
L
193/8”
W
X
10”
H
X
61/16”
Hole Cut : 41/4”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
475
FLUO
4”
F2575R
Downlight
F2575R
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Champagne finish: Add «CH» after the housing code. Ex.: F2575RCH
Housings Specifications
415/16”
125mm
Remodel
Code
F2575R
Lamp
1 X 13W
DTT
Base
GX23-2
(2 pin)
Volts
120V
Ballast
L
HPF Magn. 143/4”
W
X
59/16”
H
X
6”
Hole Cut : 45/8”
**TRIM NOT REQUIRED**
149/16”
370mm
Insulated Ceiling (IC)1
Code
1
ISF2575R
Lamp
1 X 13W
DTT
**TRIM NOT REQUIRED**
Airtight - ASTM#283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Housing finishes
-01
White
Ex.: F2575R
476
www.contrastlighting.com
Base
GX23-2
(2 pin)
Volts
120V
Ballast
L
HPF Magn. 153/16”
W
X
81/8”
Hole Cut : 45/8”
515/16”
151mm
H
X
71/2”
ø 57/16”
138mm
F2575R
Vertical
Technical Specifications
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent champagne
finish. Add «CH» to housing code.
Ex: F2575RCH
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2575RP
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2575RW
4”
FLUO
120V Class P, HPF Magnetic ballast
• Instant start
• 2 year warranty
Photometric Data
13W Magn. DTT - Clear Reflector
CANDLEPOWER DISTRIBUTION
Candelas
90°
35
75°
65
60°
95
125
45°
155
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
4.3
2.4
1.6
1.1
0.8
0.6
0.5
0.4
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 59.4%
Spacing Criteria
2.4
Certificate
S0604264
80
50 30
71 71
54 50
41 36
33 27
26 21
22 17
50
50 30
66 66
51 48
39 35
31 26
25 21
21 16
30
50 30
63 63
49 46
38 34
30 26
24 20
20 16
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
13W Magn. DTT - Champagne Reflector
CANDLEPOWER DISTRIBUTION
Candelas
90°
15
75°
45
60°
75
105
45°
135
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
3.7
2.1
1.3
0.9
0.7
0.5
0.4
0.3
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 2pin
780
120V
Input Watts
16W
Operating AMPS
0.13A
Luminaire Efficiency 50.8%
Spacing Criteria
2.4
Certificate
S0604265
80
50 30
61 61
46 43
35 31
28 23
22 18
19 14
50
50 30
56 56
44 41
33 30
26 22
21 17
18 14
30
50 30
54 54
42 40
32 29
26 22
21 17
17 14
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
477
FLUO
4”
F2575RU
Downlight
F2575RU-01
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the housing code. Ex.: F2575RU13M
Housings Specifications
5”
127mm
New Construction (NW)
Code
NWF2575RU13
NWF2575RU18
NWF2575RU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
1411/16”
1411/16”
1411/16”
W
X
X
X
10”
10”
10”
H
X
X
X
75/8”
75/8”
75/8”
Hole Cut : 45/8”
**TRIM NOT REQUIRED**
14”
355mm
Remodel
Code
F2575RU13
F2575RU18
F2575RU26
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
TTT
TTT
**TRIM NOT REQUIRED**
Housing finishes
-01
White
Ex.: F2575RU18-01
478
www.contrastlighting.com
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
143/16”
143/16”
143/16”
W
X
X
X
59/16”
59/16”
59/16”
Hole Cut : 45/8”
71/16”
180mm
H
X
X
X
71/16”
71/16”
71/16”
ø 51/2”
140mm
F2575R
Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2575RD18
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: F2575RD182
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Reflector
from trusses or suspended ceilings.
0.04’’aluminium reflector with
low iridescence semi specular
Housing Features
clear finish.
• Galvanized steel
Optional: Low iridescent matte
• Below ceiling accessible
finish. Add «M» to housing code.
• See specs in Housing Section
Ex: F2575RU18M
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
AvailableA in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
40
75°
80
60°
120
160
45°
200
0°
15°
30°
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 71.8%
Spacing Criteria
2.4
Certificate
S0601131
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Triple Tube, 4 pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 76.8%
Spacing Criteria
2.3
Certificate
S060113
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.4
3.0
1.9
1.3
1.0
0.8
0.6
0.5
DIA
2.1’
2.9’
3.6’
4.3’
5.0’
5.7’
6.4’
7.1’
80
50 30
86 86
64 59
49 42
38 32
31 25
26 20
50
50 30
80 80
60 56
46 41
36 31
30 24
25 19
30
50 30
76 75
58 55
44 40
35 30
29 24
24 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
60
75°
120
60°
180
245
45°
300
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
8.4
4.7
3.0
2.1
1.5
1.2
0.9
0.8
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
80
50 30
91 91
71 65
54 47
43 36
35 28
29 22
50
50 30
85 85
66 62
51 46
41 35
33 27
28 22
30
50 30
82 82
64 61
49 45
39 34
32 27
27 22
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
75
75°
155
60°
230
310
45°
385
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
10.6
6.0
3.8
2.7
1.9
1.5
1.2
1.0
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Triple Tube, 4 pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 68.2%
Spacing Criteria
2.3
Certificate
S0601161
Matte Reflector
0.83
Multiplier
80
50 30
81 81
62 57
47 41
37 31
30 24
25 19
50
50 30
76 76
58 54
44 39
35 30
29 23
24 19
30
50 30
73 73
56 53
43 38
34 29
28 23
23 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
479
HID FLUO
GX10
4”1/2”
3
FB2675
finitions
Downlight
FB2675-08
Vertical
modèle
Damp location
Compact fluorescent: 1 X CFQ-13W 1 X CFTR-18W 1 X CFTR-26W 1 X CFTR-32W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the housing code. Ex.: FB2675RU18M
Housings Specifications
9/16”
14mm
New Construction (NW)
Code
NWF2675RU13
NWF2675RU18
NWF2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
H
10”
10”
10”
X
X
X
75/8”
75/8”
75/8”
Hole Cut : 45/8”
Remodel
Code
F2675RU13
F2675RU18
F2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 6”
152mm
H
59/16”
59/16”
59/16”
X
X
X
71/16”
71/16”
71/16”
Hole Cut : 45/8”
ø 41/8”
105mm
Insulated Ceiling (IC)1
Code
1
ISF2675RU13
1
ISF2675RU18
1
ISF2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
193/8”
193/8”
193/8”
X
X
X
H
10”
10”
10”
X
X
X
61/16”
61/16”
61/16”
Hole Cut : 45/8”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FB2675-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FB2675-11MG
480
www.contrastlighting.com
FB2675
Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF2575RD18
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF2575RD182
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• See specs in Housing Section
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: F2675RU18M
Trims
Plated or painted steel
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
45
75°
85
60°
130
170
45°
215
0°
15°
30°
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 70.4%
Spacing Criteria
1.9
Certificate
S0601132
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 73.3%
Spacing Criteria
1.8
Certificate
S0601134
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 71.1%
Spacing Criteria
1.9
Certificate
S0601162
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.9
3.3
2.1
1.5
1.1
0.8
0.7
0.5
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
80
50 30
84 84
65 60
50 44
40 34
33 27
28 22
50
50 30
78 78
61 58
48 43
38 33
32 26
27 22
30
50 30
75 75
59 56
46 42
37 32
31 26
26 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
70
75°
145
60°
215
285
45°
355
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
9.8
5.5
3.5
2.4
1.8
1.4
1.1
0.9
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
80
50 30
92 92
73 69
58 51
46 40
38 32
32 26
50
50 30
86 86
69 66
55 50
44 39
36 31
31 25
30
50 30
82 82
67 64
53 49
43 38
36 30
30 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
90
75°
180
60°
270
360
45°
450
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
12.4
7.0
4.5
3.1
2.3
1.7
1.4
1.1
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
80
50 30
85 85
66 61
51 45
41 35
34 28
28 23
50
50 30
79 79
62 59
49 44
39 34
32 27
27 22
30
50 30
76 76
60 57
47 43
38 33
31 27
27 22
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
100
75°
200
60°
300
400
45°
500
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
13.9
7.8
5.0
3.5
2.6
2.0
1.5
1.3
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 63.5%
Spacing Criteria
1.9
Certificate
S0601171
Matte Reflector
0.83
Multiplier
80
50 30
76 76
58 54
45 39
36 30
29 24
24 19
50
50 30
71 71
54 51
52 38
34 29
28 23
23 19
30
50 30
68 68
52 50
41 37
33 29
27 23
23 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
481
FLUO
4”
FC2675
Downlight
FC2675-13
Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFTR-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the housing code. Ex.: F2675RU13M
Housings Specifications
New Construction (NW)
Code
NWF2675RU13
NWF2675RU18
NWF2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
1411/16”
1411/16”
1411/16”
X
X
X
3/16”
4mm
H
10”
10”
10”
X
X
X
75/8”
75/8”
75/8”
Hole Cut : 45/8”
Remodel
Code
F2675RU13
F2675RU18
F2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 511/16”
145mm
H
59/16”
59/16”
59/16”
X
X
X
71/16”
71/16”
71/16”
Hole Cut : 45/8”
45/16”
45/8”
109mm 117mm
Insulated Ceiling (IC)1
Code
1
ISF2675RU13
1
ISF2675RU18
1
ISF2675RU32
Lamp
1 X 13W
DTT
1 X 18W
TTT
1 X 26/32W TTT
Base
G24q-1 (4 pin)
GX24q-2 (4 pin)
GX24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
193/8”
193/8”
193/8”
X
X
X
H
10”
10”
10”
X
X
X
61/16”
61/16”
61/16”
Hole Cut : 45/8”
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
1
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FC2675-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FC2675-14MG
482
www.contrastlighting.com
FC2675
Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F2675RD32
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F2675RD322
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: F2675RU18M
Trims
Plated or painted steel
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM E283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
4”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
40
75°
80
60°
120
160
45°
200
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 71.8%
Spacing Criteria
2.4
Certificate
S0601131
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Triple Tube, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 76.8%
Spacing Criteria
2.3
Certificate
S0601133
Matte Reflector
0.83
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
5.4
3.0
1.9
1.3
1.0
0.8
0.6
0.5
DIA
2.1’
2.9’
3.6’
4.3’
5.0’
5.7’
6.4’
7.1’
80
50 30
86 86
64 59
49 42
38 32
31 25
26 20
50
50 30
80 80
60 56
46 41
36 31
30 24
25 19
30
50 30
76 76
58 55
44 40
35 30
29 24
24 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
18W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
60
75°
120
60°
180
245
45°
300
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
8.4
4.7
3.0
2.1
1.5
1.2
0.9
0.8
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
80
50 30
91 91
71 65
54 47
43 36
35 28
29 22
50
50 30
85 85
66 62
51 46
41 35
33 27
28 22
30
50 30
82 82
64 61
49 45
39 34
32 27
27 22
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
75
75°
155
60°
230
310
45°
385
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
10.6
6.0
3.8
2.7
1.9
1.5
1.2
1.0
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 68.2%
Spacing Criteria
2.3
Certificate
S0601161
Matte Reflector
0.83
Multiplier
80
50 30
81 81
62 57
47 41
37 31
30 24
25 19
50
50 30
76 76
58 54
44 39
35 30
29 23
24 19
30
50 30
73 73
56 53
43 38
34 29
28 23
23 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
483
Compact Fluorescent
Energy Efficient Lighting
6”
FLUO
6”
FR6HO
Downlight
FR6HO-11
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOM-12BR
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13
NWF6HU18
NWF6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
3/16”
5mm
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Remodel
Code
F6HU13
F6HU18
F6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HO-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOM-14MG
486
www.contrastlighting.com
FR6HO
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: FR6HOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
120
75°
240
60°
360
480
45°
600
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Two 13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W 33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 63%
Spacing Criteria
1.4 (0-180) 1.6 (90-270)
Certificate
S0612054R1
Matte Reflector
0.80
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Two 18W Quad, 4pin
2400
120V 277V 347V
Input Watts
35W
35W 38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 62%
Spacing Criteria
1.4 (0-180) 1.6 (90-270)
Certificate
S0612064R1
Matte Reflector
0.80
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
16.5
9.3
5.9
4.1
3
2.3
1.8
1.5
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
80
50 30
76 76
60 56
48 43
39 34
33 27
28 23
50
50 30
71 71
57 54
46 42
37 33
31 27
27 22
30
50 30
65 65
53 51
43 40
35 32
30 26
28 22
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
150
75°
300
60°
450
600
45°
750
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
20.4
11.5
7.3
5.1
3.7
2.9
2.3
1.8
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
80
50 30
74 74
59 55
47 42
38 33
32 27
27 22
50
50 30
69 69
55 52
44 40
36 32
30 26
26 22
30
50 30
63 63
51 49
42 39
34 31
29 25
25 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
220
75°
440
60°
660
880
45°
1100
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
29.1
16.4
10.5
7.3
5.3
4.1
3.2
2.6
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Two 26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 67%
Spacing Criteria
1.4 (0-180) 1.6 (90-270)
Certificate
S0612074R1
Matte Reflector
0.80
Multiplier
80
50 30
80 80
63 59
50 45
41 35
34 28
29 23
50
50 30
75 75
59 56
48 43
39 34
32 28
28 23
30
50 30
69 69
55 53
45 41
37 33
31 27
26 22
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
487
FLUO
6”
FR6HO
Downlight
FR6HO-11
1 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
1 X CFTR-32W
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOM-12BR
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13S
NWF6HU18S
NWF6HU26S
NWF6HU32S
Lamp
1 X 13W
1 X 18W
1 X 26W
1 X 32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
191/8”
X
X
X
X
H
10”
10”
10”
10”
X
X
X
X
3/16”
5mm
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13S
F6HU18S
F6HU26S
F6HU32S
Lamp
1 X 13W
1 X 18W
1 X 26W
1 X 32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
141/8”
X
X
X
X
H
8”
8”
8”
8”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HO-13
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOM-01MG
488
www.contrastlighting.com
FR6HO
1 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: FR6HOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
85
75°
170
60°
255
340
45°
425
0°
15°
30°
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 77.6%
Spacing Criteria
0.8 (0-180) 1(90-270)
Certificate
S0612051R1
Matte Reflector
0.76
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 75.8%
Spacing Criteria
1 (0-180) 1.1 (90-270)
Certificate
S0612061R1
Matte Reflector
0.76
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 71.1%
Spacing Criteria
1.1 (0-180) 1.1 (90-270)
Certificate
S0612071R1
Matte Reflector
0.76
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
11.3
6.3
4.1
2.8
2.1
1.6
1.3
1
DIA
0.6’
0.8’
1’
1.2’
1.3’
1.5’
1.7’
1.9’
80
50 30
92 92
72 68
58 52
48 41
40 34
35 29
50
50 30
86 86
68 64
55 50
46 40
39 33
33 28
30
50 30
79 79
63 61
52 48
43 39
37 32
32 28
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
100
75°
200
60°
300
400
45°
500
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
13.6
7.6
4.9
3.4
2.5
1.9
1.5
1.2
DIA
0.6’
0.8’
1’
1.2’
1.3’
1.5’
1.7’
1.9’
80
50 30
90 90
71 66
57 51
47 40
39 33
34 28
50
50 30
84 84
67 63
54 49
44 39
38 32
32 27
30
50 30
77 77
62 60
50 47
42 38
36 31
31 27
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
130
75°
260
60°
390
520
45°
650
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
17.7
10
6.4
4.4
3.3
2.5
2
1.6
DIA
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
80
50 30
85 85
66 61
52 46
43 36
36 30
30 25
50
50 30
79 79
62 58
49 45
41 35
34 29
29 25
30
50 30
72 72
57 55
46 43
38 34
32 28
28 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
220
75°
440
60°
660
880
45°
1100
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
29.5
16.6
10.6
7.4
5.4
4.1
3.3
2.7
DIA
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 84%
Spacing Criteria
1.1 (0-180) 1.1 (90-270)
Certificate
S0612081R1
Matte Reflector
0.76
Multiplier
80
50 30
101 101
80 75
64 57
52 45
44 37
38 31
50
50 30
94 94
75 71
61 55
50 44
42 36
36 31
30
50 30
86 86
70 67
57 53
47 43
40 35
35 30
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
489
FLUO
6”
FR6HOLA
Downlight
FR6HOLA-01
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13
NWF6HU18
NWF6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
13/16”
73/16”
73/16”
73/16”
30mm
Hole Cut : 63/4”
Remodel
Code
F6HU13
F6HU18
F6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOLA-12BR
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLA-06MG
490
www.contrastlighting.com
FR6HOLA
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD262
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26EM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
60
75°
120
60°
180
240
45°
300
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
7.9
4.4
2.8
2
1.4
1.1
0.9
0.7
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W 33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 51%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0612055R1
80
50 30
60 60
45 41
35 30
28 23
23 18
19 15
50
50 30
54 54
41 38
32 28
25 22
21 17
18 14
30
50 30
48 48
36 34
28 25
23 22
19 16
16 13
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
75
75°
150
60°
225
300
45°
375
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
9.8
5.5
3.5
2.5
1.8
1.4
1.1
0.9
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 18W Quad, 4pin
2400
120V 277V 347V
Input Watts
35W
35W 38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 52%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0612065R1
80
50 30
61 61
45 42
35 30
28 23
23 19
19 15
50
50 30
55 55
41 38
32 28
26 22
21 17
18 14
30
50 30
48 48
36 34
28 26
23 20
19 16
16 13
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
110
75°
220
60°
330
440
45°
550
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
15.2
8.6
5.5
3.8
2.8
2.1
1.7
1.4
DIA
1.7’
2.3’
2.9’
3.5’
4’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 57%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0612076R1
80
50 30
66 66
49 45
38 33
30 25
25 20
21 16
50
50 30
60 60
44 41
34 30
28 23
23 19
19 15
30
50 30
52 52
39 37
30 27
25 21
20 17
17 14
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
491
FLUO
6”
FR6HOLA
Downlight
FR6HOLA-01
1 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
1 X CFTR-32W
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13S
NWF6HU18S
NWF6HU26S
NWF6HU32S
Lamp
1 X 13W
1 X 18W
1 X 26W
1 X 32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
191/8”
X
X
X
X
H
10”
10”
10”
10”
X
X
X
X
13/16”
73/16”
73/16”
73/16”
73/16”
30mm
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13S
F6HU18S
F6HU26S
F6HU32S
Lamp
1 X 13W
1 X 18W
1 X 26W
1 X 32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
141/8”
X
X
X
X
H
8”
8”
8”
8”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOLA-04BR
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLA-05MG
492
www.contrastlighting.com
FR6HOLA
1 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
40
75°
80
60°
120
160
45°
200
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
4.9
2.8
1.8
1.2
0.9
0.7
0.5
0.4
DIA
3.7’
5’
6.2’
7.5’
8.7’
10’
11.2’
12.4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 61%
Spacing Criteria
1.1 (0-180) 1.2 (90-270)
Certificate
S0612052R1
80
50 30
72 72
54 49
41 36
33 27
27 22
23 18
50
50 30
66 66
49 45
38 33
31 26
25 21
22 17
30
50 30
58 58
44 41
34 31
28 24
23 20
20 16
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
50
75°
100
60°
150
200
45°
250
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
6.5
3.7
2.4
1.6
1.2
0.9
0.7
0.6
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 60%
Spacing Criteria
1.3 (0-180) 1.2 (90-270)
Certificate
S0612062R1
80
50 30
70 70
52 48
40 35
32 27
26 21
22 18
50
50 30
64 64
47 44
37 32
30 25
25 20
21 17
30
50 30
57 57
42 40
33 30
27 23
22 19
19 16
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
70
75°
140
60°
210
280
45°
350
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
7.7
4.3
2.8
1.9
1.4
1.1
0.9
0.7
DIA
5.7’
7.6’
9.5’
11.3’
13.2’
15.1’
17’
18.9’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 60%
Spacing Criteria
1.4 (0-180) 1.2 (90-270)
Certificate
S0612072R1
80
50 30
71 71
52 47
40 34
32 26
26 21
22 17
50
50 30
64 64
47 44
36 32
29 24
24 20
20 16
30
50 30
57 57
42 39
32 29
26 23
22 18
19 15
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
105
75°
210
60°
315
420
45°
525
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
14
7.9
5
3.5
2.6
2.0
1.6
1.3
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 69%
Spacing Criteria
1.2 (0-180) 1.2 (90-270)
Certificate
S0612082R1
80
50 30
81 81
60 55
46 40
37 31
31 25
26 20
50
50 30
73 73
55 51
42 37
34 29
28 23
24 19
30
50 30
65 65
49 46
38 34
31 27
26 22
22 18
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
493
FLUO
6”
FR6HOLB
Downlight
FR6HOLB-01
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13
NWF6HU18
NWF6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
13/16”
73/16”
73/16”
73/16”
30mm
Hole Cut : 63/4”
Remodel
Code
F6HU13
F6HU18
F6HU26
Lamp
2 X 13W
2 X 18W
2 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOLB-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLB-11MG
494
www.contrastlighting.com
FR6HOLB
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD262
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26EM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
75
75°
150
60°
225
300
45°
375
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
10.1
5.7
3.6
2.5
1.9
1.4
1.1
0.9
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W 33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 55%
Spacing Criteria
1.2 (0-180) 1.3 (90-270)
Certificate
S0612056R1
80
50 30
65 65
49 46
39 34
31 26
26 21
22 18
50
50 30
59 59
45 42
35 32
29 25
24 20
21 17
30
50 30
52 52
40 38
32 29
26 23
22 19
19 16
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
95
75°
190
60°
285
380
45°
475
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
12.9
7.3
4.7
3.2
2.4
1.8
1.4
1.2
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 18W Quad, 4pin
2400
120V 277V 347V
Input Watts
35W
35W 38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 56%
Spacing Criteria
1.2 (0-180) 1.3 (90-270)
Certificate
S0612066R1
80
50 30
65 65
49 46
39 34
31 26
26 21
22 18
50
50 30
59 59
45 42
35 31
29 25
24 20
20 17
30
50 30
52 52
40 38
31 29
26 23
22 19
19 16
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
140
75°
280
60°
420
560
45°
700
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
18.8
10.5
6.8
4.7
3.4
2.6
2.1
1.7
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 60%
Spacing Criteria
1.2 (0-180) 1.3 (90-270)
Certificate
S0612077R1
80
50 30
70 70
53 49
41 36
33 28
27 22
23 19
50
50 30
63 63
48 45
38 33
31 26
25 21
22 18
30
50 30
56 56
42 40
33 30
27 24
23 20
20 17
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
495
FLUO
6”
FR6HOLB
Downlight
FR6HOLB-01
1 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
1 X CFTR-32W
Reflector
Standard: semi-specular low iridescence aluminum
11/2”
38mm
Housings Specifications
53/4”
146mm
New Construction (NW)
Code
NWF6HU13S
NWF6HU18S
NWF6HU26S
NWF6HU32S
Lamp
1x13W
1X18W
1X26W
1X32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
191/8”
X
X
X
X
H
10”
10”
10”
10”
X
X
X
X
13/16”
73/16”
73/16”
73/16”
73/16”
30mm
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13S
F6HU18S
F6HU26S
F6HU32S
Lamp
1x13W
1X18W
1X26W
1X32W
DTT
DTT
DTT
TTT
Base
G24q-1
G24q-2
G24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
141/8”
X
X
X
X
H
8”
8”
8”
8”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOLB-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOLB-05MG
496
www.contrastlighting.com
FR6HOLB
1 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
55
75°
110
60°
165
220
45°
275
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
7
4
2.5
1.8
1.3
1
0.8
0.7
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 66%
Spacing Criteria
0.9 (0-180) 0.9 (90-270)
Certificate
S0612053R1
80
50 30
77 77
58 54
46 40
37 31
31 26
26 21
50
50 30
71 71
53 50
42 38
35 30
29 24
25 21
30
50 30
63 63
48 46
38 35
32 28
27 23
23 20
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
65
75°
130
60°
195
260
45°
325
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
8.8
4.9
3.2
2.2
1.6
1.2
1
0.8
DIA
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 60%
Spacing Criteria
0.9 (0-180) 1.0 (90-270)
Certificate
S0612063R1
80
50 30
72 72
54 50
42 37
34 29
29 24
24 20
50
50 30
67 67
51 47
40 35
33 28
27 23
24 19
30
50 30
62 62
47 44
37 34
31 27
26 22
22 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
90
75°
180
60°
270
360
45°
450
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
11.7
6.6
4.2
2.9
2.1
1.6
1.3
1.1
DIA
0.8’
1.1’
1.4’
1.7’
2’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 63%
Spacing Criteria
1.1 (0-180) 1.0 (90-270)
Certificat
S0612073R1
80
50 30
74 74
55 51
43 37
35 29
29 24
25 20
50
50 30
68 68
51 47
40 35
32 28
27 22
23 19
30
50 30
60 60
45 43
36 32
29 26
25 21
21 18
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
140
75°
280
60°
420
560
45°
700
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
18.6
10.5
6.7
4.6
3.4
2.6
2.1
1.7
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 71%
Spacing Criteria
1.0 (0-180) 1.0 (90-270)
Certificate
S0612084R1
80
50 30
84 84
63 58
50 43
40 34
33 28
29 23
50
50 30
76 76
58 54
46 41
37 32
31 26
27 22
30
50 30
68 68
52 49
41 38
34 30
29 25
25 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
497
FLUO
6”
FR6HOW90
90° Wall Wash
FR6HOW90-04BR
2 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
2 X CFTR-26W
Reflector
Standard: semi-specular low iridescence aluminum
13/8”
35mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW90M-12BR
Housings Specifications
New Construction (NW)
Code
NWF6HU13
NWF6HU18
NWF6HU26
Lamp
2X13W DTT
2X18W DTT
2X26W DTT/TTT
Base
Volts
(4 pin) 120-277V
G24q-1
(4 pin) 120-277V
G24q-2
G24q-3/GX24q-3 (4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
57/8”
149mm
H
10”
10”
10”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13
F6HU18
F6HU26
Lamp
2X13W DTT
2X18W DTT
2X26W DTT/TTT
Base
Volts
(4 pin) 120-277V
G24q-1
(4 pin) 120-277V
G24q-2
G24q-3/GX24q-3 (4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
X
X
X
H
8”
8”
8”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOW90-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW90-01MG
498
www.contrastlighting.com
FR6HOW90
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD262
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26EM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6HOMW90
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
115
75°
75°
230
60°
60°
340
45°
45°
455
30°
90°
15°
570
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W 33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 65%
Spacing Criteria
1.2 (0-180) 1.6 (90-270)
Certificate
S0806021R1
30°
80
50 30
78 78
61 57
48 43
39 33
32 27
26 22
50
50 30
73 73
57 54
46 41
37 32
31 26
26 22
10
50 30
67 67
53 51
43 39
35 31
29 26
25 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
145
75°
75°
295
60°
60°
440
45°
45°
585
30°
90°
15°
730
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
2400
120V 277V 347V
Input Watts
35W
35W 38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 63%
Spacing Criteria
1.2 (0-180) 1.6 (90-270)
Certificate
S0805301R1
30°
80
50 30
75 75
59 55
47 42
38 33
31 26
27 22
50
50 30
70 70
56 53
44 40
36 32
30 26
26 21
10
50 30
64 64
52 50
42 39
34 31
29 25
25 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
185
75°
75°
370
60°
60°
560
45°
45°
745
30°
90°
15°
930
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 58%
Spacing Criteria
1.3 (0-180) 1.5 (90-270)
Certificate
S0805272R1
30°
80
50 30
68 68
54 50
43 38
35 30
29 24
24 20
50
50 30
64 64
51 48
41 37
33 29
28 24
24 20
10
50 30
59 59
47 45
38 35
31 28
26 23
22 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
2 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
220
75°
75°
440
60°
45°
90°
60°
660
45°
880
30°
15°
0°
1100
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
3600
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 60%
Spacing Criteria
1.1 (0-180) 1.7 (90-270)
Certificate
S0805281R1
80
50 30
72 72
56 53
45 40
36 31
30 25
25 21
50
50 30
67 67
53 50
42 38
35 30
29 25
25 20
10
50 30
61 61
50 48
40 37
33 29
27 24
23 20
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
499
FLUO
6”
FR6HOW90
90° Wall Wash
FR6HOW90-04BR
1 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
1 X CFTR-32W
Reflector
Standard: semi-specular low iridescence aluminum
13/8”
35mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW90M-12BR
Housings Specifications
New Construction (NW)
Code
NWF6HU13S
NWF6HU18S
NWF6HU26S
NWF6HU32S
Lamp
1X13W
1X18W
1X26W
1X32W
DTT
DTT
TTT
TTT
Base
G24q-1
G24q-2
GX24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
191/8”
X
X
X
X
57/8”
149mm
H
10”
10”
10”
10”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13S
F6HU18S
F6HU26S
F6HU32S
Lamp
1X13W
1X18W
1X26W
1X32W
DTT
DTT
TTT
TTT
Base
G24q-1
G24q-2
GX24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
141/8”
X
X
X
X
H
8”
8”
8”
8”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOW90-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW90-01MG
500
www.contrastlighting.com
FR6HOW90
1 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6HOMW90
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
80
75°
75°
155
60°
60°
235
45°
90°
45°
315
30°
15°
390
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 71%
Spacing Criteria
1.3 (0-180) 1.1 (90-270)
Certificate
S0806024R1
80
50 30
85 85
67 62
53 47
44 38
37 31
32 26
50
50 30
79 79
63 60
51 46
42 37
35 30
31 26
10
50 30
73 73
59 56
47 44
40 36
34 30
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
90
75°
75°
185
60°
60°
275
45°
45°
370
30°
90°
15°
460
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 67%
Spacing Criteria
1.3 (0-180) 1.1 (90-270)
Certificate
S0805304R1
30°
80
50 30
80 80
63 59
50 45
41 36
35 29
30 25
50
50 30
75 75
60 56
48 43
39 35
33 29
29 24
10
50 30
69 69
55 53
45 42
37 33
32 28
27 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
150
75°
75°
295
60°
60°
445
45°
90°
45°
595
30°
15°
740
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 72%
Spacing Criteria
1.2 (0-180) 1.1 (90-270)
Certificate
S0805294R1
80
50 30
86 86
68 63
54 48
44 38
37 32
32 27
50
50 30
80 80
64 61
51 47
42 37
36 31
31 26
10
50 30
74 74
59 57
48 45
40 36
34 30
30 26
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
220
75°
75°
440
60°
45°
90°
60°
660
45°
880
30°
15°
1100
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 81%
Spacing Criteria
1.2 (0-180) 1.2 (90-270)
Certificate
S0805293R1
80
50 30
96 96
76 71
60 54
49 43
41 35
36 29
50
50 30
90 90
72 68
57 52
47 42
40 34
34 29
10
50 30
83 83
67 64
54 50
45 40
38 33
33 28
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
501
FLUO
6”
FR6HOW120
120° Wall Wash
FR6HOW120-01
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
13/8”
35mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW120M-12BR
Housings Specifications
New Construction (NW)
Code
NWF6HU13
NWF6HU18
NWF6HU26
Lamp
2X13W
2X18W
2X26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
57/8”
149mm
H
10”
10”
10”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13
F6HU18
F6HU26
Lamp
2X13W
2X18W
2X26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
X
X
X
H
8”
8”
8”
X
X
X
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOW120-02
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW120-02MG
502
www.contrastlighting.com
FR6HOW120
2 x DTTHorizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD262
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26EM
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: F2675RU18M
Trims
Plated or painted steel
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
130˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM#283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
105
75°
75°
215
60°
60°
320
45°
45°
425
30°
90°
15°
530
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W 33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 62%
Spacing Criteria
1.2 (0-180) 1.5 (90-270)
Certificate
S0806022R1
30°
80
50 30
74 74
57 54
45 40
37 31
30 25
26 21
50
50 30
69 69
54 51
43 39
35 30
29 25
25 20
10
50 30
63 63
50 48
40 37
33 29
28 24
24 20
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
140
75°
75°
280
60°
60°
420
45°
45°
560
30°
90°
15°
700
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
2400
120V 277V 347V
Input Watts
35W
35W 38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 64%
Spacing Criteria
1.2 (0-180) 1.5 (90-270)
Certificate
S0805302R1
30°
80
50 30
76 76
59 55
47 42
38 32
31 26
27 22
50
50 30
71 71
56 53
44 40
36 32
30 26
26 21
10
50 30
65 65
52 50
42 38
34 31
29 25
25 21
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
180
75°
75°
360
60°
60°
540
45°
90°
45°
720
30°
15°
900
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W 57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 57%
Spacing Criteria
1.3 (0-180) 1.5 (90-270)
Certificat
S0805271R1
80
50 30
68 68
53 50
42 37
34 29
28 24
24 20
50
50 30
64 64
50 47
40 36
32 28
27 23
23 19
10
50 30
59 59
47 45
37 34
31 27
26 22
22 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
503
FLUO
6”
FR6HOW120
120° Wall Wash
FR6HOW120-01
1 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFTR-26W
** Lamps must meet ANSI requirements.**
1 X CFTR-32W
Reflector
Standard: semi-specular low iridescence aluminum
13/8”
35mm
Matte iridescence free: Add «M» after the trim code. Ex.: FR6HOW120M-12BR
Housings Specifications
New Construction (NW)
Code
NWF6HU13S
NWF6HU18S
NWF6HU26S
NWF6HU32S
Lamp
1X13W
1X18W
1X26W
1X32W
DTT
DTT
TTT
TTT
Base
G24q-1
G24q-2
GX24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
191/8”
X
X
X
X
57/8”
149mm
H
10”
10”
10”
10”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
ø 8”
203mm
Remodel
Code
F6HU13S
F6HU18S
F6HU26S
F6HU32S
Lamp
1X13W
1X18W
1X26W
1X32W
DTT
DTT
TTT
TTT
Base
G24q-1
G24q-2
GX24q-3
GX24q-3
(4
(4
(4
(4
pin)
pin)
pin)
pin)
Volts
120-277V
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
Electronic
L
W
141/8”
141/8”
141/8”
141/8”
X
X
X
X
H
8”
8”
8”
8”
X
X
X
X
73/16”
73/16”
73/16”
73/16”
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6HOW120-02
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6HOW120-02MG
504
www.contrastlighting.com
FR6HOW120
1 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6HD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6HD26S2
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6HD26SEM
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6HOMW120
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
75
75°
75°
150
60°
60°
225
45°
90°
45°
295
30°
15°
370
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 70%
Spacing Criteria
1.2 (0-180) 0.9 (90-270)
Certificate
S0806023R1
80
50 30
83 83
64 60
51 45
42 36
35 30
31 25
50
50 30
77 77
61 57
48 44
40 35
34 29
29 25
10
50 30
71 71
56 54
45 42
38 34
32 28
28 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
90
75°
75°
180
60°
60°
270
45°
45°
360
30°
90°
15°
450
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 66%
Spacing Criteria
1.3 (0-180) 1.0 (90-270)
Certificate
S0805303R1
30°
80
50 30
79 79
61 57
49 43
40 34
34 28
29 24
50
50 30
73 73
58 55
46 42
38 33
32 28
28 23
10
50 30
67 67
54 52
43 40
36 32
31 27
27 23
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
150
75°
75°
300
60°
60°
450
45°
90°
45°
600
30°
15°
750
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 70%
Spacing Criteria
1.2 (0-180) 1.0 (90-270)
Certificate
S0805291R1
80
50 30
83 83
65 61
52 46
42 37
36 30
31 26
50
50 30
78 78
61 58
49 44
41 36
34 30
30 25
10
50 30
72 72
57 55
46 43
38 34
33 29
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
180
75°
75°
355
60°
45°
90°
60°
535
45°
715
30°
15°
890
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 69%
Spacing Criteria
1.2 (0-180) 1.1 (90-270)
Certificate
S0805292R1
80
50 30
82 82
64 60
51 45
42 36
35 29
30 25
50
50 30
76 76
60 57
48 44
40 35
34 29
29 24
10
50 30
70 70
56 54
45 42
38 34
32 28
28 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
505
FLUO
6”
FR6VO
Downlight
FR6VO-11
1 x DTT Narrow Flood Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-08
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
Base
DTT
G24q-1
DTT
G24q-2
DTT/TTT G24q-3
Volts
(4 pin) 120-277V
(4 pin) 120-277V
(4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VO-13
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-14MG
506
www.contrastlighting.com
FR6VO
1 x DTT Narrow Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
180
75°
360
60°
540
720
45°
900
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
24.3
13.7
8.8
6.1
4.5
3.4
2.7
2.2
0.4’
0.5’
0.6’
0.7’
0.8’
1’
1.1’
1.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W 18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 75%
Spacing Criteria
0.6
Certificate
S0611231R1
Matte Reflector
0.82
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W 19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 72%
Spacing Criteria
0.6
Certificate
S0611244R1
Matte Reflector
0.82
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
90 90
77 74
67 62
58 53
51 46
45 41
50
50 30
84 84
74 71
64 61
56 52
50 46
44 40
30
50 30
77 77
69 68
61 59
54 51
48 45
43 40
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 18W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
240
75°
480
60°
720
960
45°
1200
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
30.6
17.2
11
7.7
5.6
4.3
3.4
2.8
0.4’
0.5’
0.6’
0.7’
0.8’
1’
1.1’
1.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
80
50 30
86 86
74 71
64 59
55 51
48 44
43 38
50
50 30
80 80
70 68
61 58
53 50
47 43
42 38
30
50 30
74 74
66 65
58 56
51 48
46 42
41 37
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 26W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
300
75°
600
60°
900
1200
45°
1500
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
40
22.5
14.4
10
7.3
5.6
4.4
3.6
0.4’
0.5’
0.6’
0.7’
0.8’
1’
1.1’
1.2’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W 28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 73%
Spacing Criteria
0.6
Certificate
S0611281R1
Matte Reflector
0.82
Multiplier
80
50 30
87 87
74 70
62 58
54 49
47 42
41 36
50
50 30
81 81
70 67
60 56
52 48
45 41
40 36
30
50 30
74 74
66 64
57 54
50 47
44 40
39 35
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
507
FLUO
6”
FR6VO
Downlight
FR6VO-11
1 x TTT Narrow Flood Vertical
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-08
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
Lamp
NWF6VU42 1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
X
H
10”
X
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
Volts
Ballast
L
GX/G24q-3/q-4 (4 pin) 120-277V Electronic 143/16”
W
X
H
8”
X
93/16”
ø 8”
203mm
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VO-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-02MG
508
www.contrastlighting.com
FR6VO
1 x TTT Narrow Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
300
75°
600
60°
900
1200
45°
1500
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
39.5
22.2
14.2
9.9
7.3
5.6
4.4
3.6
0.5’
0.6’
0.8’
0.9’
1.1’
1.2’
1.4’
1.6’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILIZATION - %
LUMINAIRE
Lamp Type
Initial Lumens
26W Triple Tube, 4pin Ceiling Reflect % 80
50
30
Wall Reflect %
50 30 50 30 50 30
1800
120V 277V 347V RCR
0
85 85 80 80 73 73
Input Watts
28W 28W 31W
2
73 70 70 68 66 64
Operating AMPS
0.25A 0.11A 0.09A
4
63 59 61 58 58 56
Luminaire Efficiency 71%
6
55 51 53 50 52 49
8
48 44 47 43 46 43
Spacing Criteria
0.8
10
43 39 42 38 41 38
Certificate
S0611293R1
Matte Reflector
Zonal Cavity Method Effective Floor
0.82
Multiplier
Cavity Reflectance 20%
1 X 32W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
300
75°
720
60°
1080
1440
45°
1800
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
47.7
26.8
17.2
11.9
8.8
6.7
5.3
4.3
0.6’
0.8’
1’
1.2’
1.3’
1.5’
1.7’
1.9’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILIZATION - %
LUMINAIRE
50
30
32W Triple Tube, 4pin Ceiling Reflect % 80
Wall Reflect %
50 30 50 30 50 30
2400
0
93 93 86 86 79 79
120V 277V 347V RCR
Input Watts
36W 36W 36W
2
78 75 74 72 70 68
Operating AMPS
0.30A 0.13A 0.11A
4
66 61 64 60 60 57
6
57 51 55 50 52 49
Luminaire Efficiency 78%
8
49 44 48 43 46 42
Spacing Criteria
0.8
10
43 38 42 37 41 37
Certificate
S0611303R1
Matte Reflector
Zonal
Cavity
Method
Effective Floor
0.82
Multiplier
Cavity Reflectance 20%
Lamp Type
Initial Lumens
1 X 42W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
460
75°
920
60°
1380
1840
45°
2300
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
61.8
34.7
22.2
15.4
11.3
8.7
6.9
5.6
0.5’
0.6’
0.8’
0.9’
1.1’
1.2’
1.4’
1.6’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
COEFFICIENT OF UTILIZATION - %
LUMINAIRE
50
30
42W Triple Tube, 4pin Ceiling Reflect % 80
Wall Reflect %
50 30 50 30 50 30
3200
120V 277V 347V RCR
0
87 87 81 81 74 74
Input Watts
48W 48W 50W
2
73 70 69 67 65 63
Operating AMPS
0.41A 0.18A 0.15A
4
53 48 51 47 49 46
Luminaire Efficiency 72%
6
53 48 51 47 49 46
8
46 41 44 40 43 39
Spacing Criteria
0.7
10
40 35 39 35 38 35
Certificate
S0612041R1
Matte Reflector
Zonal Cavity Method Effective Floor
0.82
Multiplier
Cavity Reflectance 20%
Lamp Type
Initial Lumens
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
509
FLUO
6”
FR6VO
Open
FR6VO-11
1 x DTT Wide Flood Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-06
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
(4 pin) 120-277V
(4 pin) 120-277V
(4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VO-13
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-14MG
510
www.contrastlighting.com
FR6VO
1 x DTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
140
75°
280
60°
420
560
45°
700
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
19.1
10.8
6.9
4.8
3.5
2.7
2.1
1.7
0.5’
0.6’
0.8’
0.9’
1.1’
1.2’
1.4’
1.6’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
13W Quad Tube, 4pin
900
120V 277V 347V
Input Watts
18W 18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 82%
Spacing Criteria
0.6
Certificate
S0611241R1
Matte Reflector
0.82
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
18W Quad Tube, 4pin
1200
120V 277V 347V
Input Watts
19W 19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 81%
Spacing Criteria
0.6
Certificate
S0611273R1
Matte Reflector
0.82
Multiplier
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
98 98
82 78
68 63
58 52
50 44
43 38
50
50 30
91 91
78 75
65 61
56 51
48 43
42 37
30
50 30
84 84
73 71
62 59
53 50
46 42
41 37
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 18W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
160
75°
320
60°
480
640
45°
800
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
22.1
12.5
8
5.5
4.1
3.1
2.5
2
0.5’
0.6’
0.8’
0.9’
1.1’
1.2’
1.4’
1.6’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
80
50 30
97 97
80 75
65 59
54 48
46 40
40 34
50
50 30
91 91
75 72
62 58
52 47
45 39
39 34
30
50 30
83 83
71 68
59 55
50 46
43 39
37 33
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 26W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
240
75°
480
60°
720
960
45°
1200
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
17.6
9.9
6.3
4.4
3.2
2.5
2
1.6
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
26W Quad Tube, 4pin
1710
120V 277V 347V
Input Watts
28W 28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 80%
Spacing Criteria
0.6
Certificate
S0611284R1
Matte Reflector
0.82
Multiplier
80
50 30
96 96
77 73
63 57
52 46
44 38
38 33
50
50 30
90 90
73 70
60 55
50 45
43 37
37 32
30
50 30
82 82
68 66
56 53
48 43
41 37
36 31
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
511
FLUO
6”
FR6VO
Downlight
FR6VO-11
1 x TTT Wide Flood Vertical
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOM-05
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
X
H
10”
X
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
Ballast
L
W
H
(4 pin) 120-277V Electronic 143/16” X 8”
X
93/16”
ø 8”
203mm
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VO-01
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VO-05MG
512
www.contrastlighting.com
FR6VO
1 x TTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOM
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
130˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
240
75°
480
60°
720
960
45°
1200
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
31.2
17.6
11.2
7.8
5.7
4.4
3.5
2.8
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILISATION - %
LUMINAIRE
Lamp Type
Initial Lumens
26W Triple Tube, 4pin Ceiling Reflect % 80
50
30
Wall Reflect %
50 30 50 30 50 30
1800
120V 277V 347V RCR
0
91 91 85 85 78 78
Input Watts
28W 28W 31W
2
76 73 72 70 68 66
Operating AMPS
0.25A 0.11A 0.09A
4
64 59 62 58 58 56
Luminaire Efficiency 76%
6
54 49 53 48 50 47
8
47 42 45 41 44 40
Spacing Criteria
0.9
10
41 36 40 35 38 35
Certificat
S0611296R1
Matte Reflector
Zonal Cavity Method Effective Floor
0.82
Multiplier
Cavity Reflectance 20%
1 X 32W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
300
75°
600
60°
900
1200
45°
1500
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
39.2
12.5
8
5.5
4.1
3.1
2.5
2
0.8’
1.1’
1.4’
1.7’
2’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILISATION - %
LUMINAIRE
50
30
32W Triple Tube, 4pin Ceiling Reflect % 80
Wall Reflect %
50 30 50 30 50 30
2400
0
106 106 99 99 91 91
120V 277V 347V RCR
Input Watts
36W 36W 36W
2
87 82 82 78 77 74
Operating AMPS
0.30A 0.13A 0.11A
4
71 64 67 62 64 60
6
59 52 56 51 54 49
Luminaire Efficiency 89%
8
50 43 48 42 46 41
Spacing Criteria
0.9
10
43 36 42 36 40 35
Certificat
S0612013R1
Matte Reflector
Zonal
Cavity
Method
Effective Floor
0.82
Multiplier
Cavity Reflectance 20%
Lamp Type
Initial Lumens
1 X 42W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
360
75°
720
60°
1080
1440
45°
1800
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
49.5
27.8
17.5
12.4
9.1
7
5.5
4.5
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILISATION - %
Lamp Type
Initial Lumens
Ceiling Reflect % 80
Wall Reflect %
50 30
RCR
0
102 102
2
82 77
4
66 60
6
55 48
8
47 40
42W Triple Tube, 4pin
3200
120V 277V 347V
Input Watts
48W 48W 50W
Operating AMPS
0.41A 0.18A 0.15A
Luminaire Efficiency 85%
Spacing Criteria
0.8
Certificat
S0612044R1
Matte Reflector
0.82
Multiplier
50
50 30
95 95
78 74
63 58
53 47
45 39
30
50 30
88 88
72 70
60 56
50 46
43 38
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
513
4”
6
FLUO
FR6VOG-O4FUR05
FR6VOG-O4RFF07
FR6VOG-O4BRIND03
FR6VOG
Downlight
Vertical
FR6VOG-O4WFF00
Damp location
Compact fluorescent: 1 X 13W DTT
1 X 18W DTT
1 X 26W DTT
Reflector
93/16”
233mm
Standard: semi-specular low iridescence aluminum
3/16”
5mm
Housings Specifications
3”
76mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
Base
G24q-1
G24q-2
G24q-3
DTT
DTT
DTT
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
5”
127mm
93/16”
93/16”
93/16”
7”
178mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
Base
G24q-1
G24q-2
G24q-3
DTT
DTT
DTT
Volts
Ballast
L
W
H
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
X
X
X
ø 6 3/16”
157mm
93/16”
93/16”
93/16”
Ø 8”
203mm
Hole Cut : 63/4”
Glass Colors
FUR
IND
Furia
SUN
India
A
M
Sunset
Amber
R
Eggplant
B
Red
Clobalt
Blue
W
CAR
White
Caramel
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOG-05SUNC05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOG-01MGFUR03
514
www.contrastlighting.com
FR6VOG
Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
FR6VOG
Trim codification
MODEL
FR6VOG
Listings
• cULus Listed for through branch
wiring and damp location.
6”
Specs and codification
FR6VOG-04BRWFFOO
TRIM FINISH
GLASS COLOR
GLASS TEXTURE
GLASS LENGTH
-04BR
W
FF
00
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
FLUO
• 277V: For dimming capability, change «U» Locking System
to «D» and add «2» at the end of the housing • Perfect fit to ceiling
code of 18W to 42W. Ex: NWF6VD26S2
• No light leak
• Hooks PAT #CAN. 2.088.648
Mounting Bars
and #USA. 5.377.088
• For NW.
• Adjustable and lockable from 10” to 24”. • Take up to 7/8” thick ceilings
• Lockable integral T-Bar tabs. May be hung Reflector
from trusses or suspended ceilings.
0.04’’aluminium reflector with
low iridescence semi specular
Housing Features
clear finish.
• Galvanized steel
• Below ceiling accessible
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
FUR
IND
CAR
B
M
R
A
W
SUN
Furia
India
Caramel
Cobalt Blue
Amber
Red
Eggplant
White
Sunset
EXCEPTION :
There is no texture
to specify for Furia
and India glass.
FF
Frosted int./ext.
C
Clear
00
03
05
07
Flush (0”)
3” of the trim
5” of the trim
7” of the trim
515
FLUO
6”
FR6VOLA
1 x DTT Wide Flood Vertical
FR6VOLA-01
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
13/16”
30mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
H
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
X
X
X
93/16”
93/16”
93/16”
ø 8”
203mm
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOLA-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLA-11MG
516
www.contrastlighting.com
FR6VOLA
1 x DTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
55
75°
110
60°
165
220
45°
275
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
7.3
4.1
2.6
1.8
1.3
1
0.8
0.7
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad Tube, 4pin
900
120V 277V 347V
Input Watts
18W 18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 62%
Spacing Criteria
1
Certificate
S0611242R1
80
50 30
73 73
57 53
45 40
37 32
31 26
26 22
50
50 30
67 67
53 50
42 38
35 30
29 25
25 21
30
50 30
61 61
48 46
39 36
32 29
27 24
24 20
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 18W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
65
75°
130
60°
200
265
45°
330
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
9
5
3.2
2.2
1.6
1.2
1
0.8
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W 19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 61%
Spacing Criteria
1
Certificate
S0611274R1
80
50 30
72 72
56 52
44 39
36 30
29 24
24 20
50
50 30
66 66
52 49
41 37
34 29
28 24
24 20
30
50 30
60 60
47 45
38 35
31 28
26 23
23 19
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 26W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
90
75°
180
60°
270
360
45°
450
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
12.4
7
4.5
3.1
2.3
1.8
1.4
1.1
0.8’
1.1’
1.4’
1.7’
2’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad Tube, 4pin
1710
120V 277V 347V
Input Watts
28W 28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 59%
Spacing Criteria
1
Certificate
S0611285R1
80
50 30
70 70
54 50
42 37
34 29
29 24
24 20
50
50 30
65 65
50 47
40 36
32 28
27 23
23 19
30
50 30
58 58
45 43
36 33
30 27
43 38
22 18
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
517
FLUO
6”
FR6VOLA
1 x TTT Wide Flood Vertical
FR6VOLA-01
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
Lamp
NWF6VU42 1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
X
H
10”
X
93/16”
X
93/16”
Hole Cut : 63/4”
13/16”
30mm
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
Ballast
L
W
H
(4 pin) 120-277V Electronic 143/16” X 8”
Hole Cut : 63/4”
ø 8”
203mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOLA-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLA-11MG
518
www.contrastlighting.com
FR6VOLA
1 x TTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
100
75°
200
60°
300
400
45°
500
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
13.3
7.5
4.8
3.3
2.4
1.9
1.5
1.2
0.8’
1.1’
1.4’
1.7’
2’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILISATION - %
Lamp Type
Initial Lumens
80
50 30
67 67
52 49
41 37
34 29
28 24
24 20
26W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
1800
120V 277V 347V RCR
0
Input Watts
28W 28W 31W
2
Operating AMPS
0.25A 0.11A 0.09A
4
Luminaire Efficiency 56%
6
8
Spacing Criteria
1
10
Certificat
S0611301R1
50
50 30
61 61
48 46
39 35
32 28
27 23
23 20
30
50 30
55 55
44 42
36 33
30 27
25 22
22 19
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 32W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
135
75°
270
60°
405
540
45°
675
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
18.5
10.4
6.7
4.6
3.4
2.6
2.1
1.7
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILISATION - %
LUMINAIRE
32W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
2400
0
120V 277V 347V RCR
Input Watts
36W 36W 36W
2
Operating AMPS
0.30A 0.13A 0.11A
4
6
Luminaire Efficiency 66%
8
Spacing Criteria
1.1
10
Certificat
S06112014R1
Lamp Type
Initial Lumens
80
50 30
78 78
60 56
47 42
38 33
32 27
27 22
50
50 30
72 72
56 53
44 40
36 31
30 26
26 22
30
50 30
65 65
51 49
41 37
33 30
28 25
24 21
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 42W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
165
75°
330
60°
500
665
45°
830
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
18.5
10.4
6.7
4.6
3.4
2.6
2.1
1.7
1’
1.3’
1.7’
2’
2.3’
2.7’
3’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
COEFFICIENT OF UTILISATION - %
LUMINAIRE
42W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
3200
120V 277V 347V RCR
0
Input Watts
48W 48W 50W
2
Operating AMPS
0.41A 0.18A 0.15A
4
Luminaire Efficiency 63%
6
8
Spacing Criteria
1
10
Certificat
S0612045R1
Lamp Type
Initial Lumens
80
50 30
75 75
58 53
45 40
37 31
30 25
26 21
50
50 30
69 69
53 50
42 38
34 30
29 24
25 20
30
50 30
62 62
48 46
38 35
32 28
27 23
23 16
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
519
FLUO
6”
FR6VOLB
1 x DTT Wide Flood Vertical
FR6VOLB-01
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
FLUO
Standard: semi-specular low iridescence aluminum
Housings Specifications
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
Max 9”
229mm
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
13/16”
30mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
H
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
(4 pin) 120-277V Electronic 143/16” X 8”
X
X
X
93/16”
93/16”
93/16”
ø 8”
203mm
Hole Cut : 63/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOLB-02
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLB-02MG
520
www.contrastlighting.com
FR6VOLB
1 x DTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
80
75°
160
60°
240
320
45°
400
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
10.9
6.1
3.9
2.7
2
1.5
1.2
1
0.6’
0.8’
1’
1.2’
1.3’
1.5’
1.7’
1.9’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad Tube, 4pin
900
120V 277V 347V
Input Watts
18W 18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 67%
Spacing Criteria
1
Certificate
S0611243R1
80
50 30
80 80
64 60
52 46
43 37
36 31
31 26
50
50 30
74 74
60 57
49 44
41 36
35 30
30 26
30
50 30
67 67
55 53
45 42
38 35
33 29
29 25
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 18W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
95
75°
190
60°
285
380
45°
475
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
13
7.3
4.7
3.2
2.4
1.8
1.4
1.2
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad Tube, 4pin
1200
120V 277V 347V
Input Watts
19W 19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 66%
Spacing Criteria
0.8
Certificate
S0611275R1
80
50 30
78 78
62 58
50 44
41 35
34 29
30 25
50
50 30
72 72
58 54
46 42
39 34
33 28
28 24
30
50 30
65 65
53 51
43 40
36 33
31 27
27 23
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 26W Elect. DTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
120
75°
240
60°
260
480
45°
600
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
17.6
9.9
6.3
4.4
3.2
2.5
2
1.6
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad Tube, 4pin
1710
120V 277V 347V
Input Watts
28W 28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 64%
Spacing Criteria
0.8
Certificate
S0611291R1
80
50 30
76 76
59 55
47 42
39 34
33 28
28 24
50
50 30
70 70
55 52
44 40
37 32
31 27
27 23
30
50 30
63 63
50 48
41 38
34 31
29 26
26 22
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
521
FLUO
6”
FR6VOLB
1 x TTT Wide Flood Vertical
FR6VOLB-01
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
Lamp
NWF6VU42 1 X 26/32/42W TTT
Base
GX24q-3/q-4
(4 pin)
Volts
Ballast
L
120-277V Electronic 191/8”
W
X
H
10”
X
93/16”
X
93/16”
Hole Cut : 63/4”
13/16”
30mm
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4
(4 pin)
Volts
Ballast
L
120-277V Electronic 143/16”
W
X
H
8”
Hole Cut : 63/4”
ø 8”
203mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOLB-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR6VOLB-14MG
522
www.contrastlighting.com
FR6VOLB
1 x TTT Wide Flood Vertical
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF6VD26S
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION
CONE OF LIGHT
Candelas
90° Distance FC
DIA
140
75°
280
60°
420
560
45°
700
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
19.4
10.9
7
4.8
3.6
2.7
2.2
1.7
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
80
50 30
73 73
58 55
47 43
39 34
33 29
29 24
26W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
1800
120V 277V 347V RCR
0
Input Watts
28W 28W 31W
2
Operating AMPS
0.25A 0.11A 0.09A
4
Luminaire Efficiency 61%
6
8
Spacing Criteria
0.9
10
Certificate
S0611302R1
50
50 30
67 67
54 52
45 41
37 33
32 28
28 24
30
50 30
61 61
50 48
41 39
35 32
30 27
26 23
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 32W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
185
75°
370
60°
555
740
45°
925
0°
15°
06’
08’
10’
12’
14’
16’
18’
20’
25.1
14.1
9
6.3
4.6
3.5
2.8
2.3
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
COEFFICIENT OF UTILIZATION - %
LUMINAIRE
32W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
2400
0
120V 277V 347V RCR
Input Watts
36W 36W 36W
2
Operating AMPS
0.30A 0.13A 0.11A
4
6
Luminaire Efficiency 70%
8
Spacing Criteria
0.6
10
Certificate
S0612015R1
Lamp Type
Initial Lumens
80
50 30
84 84
66 61
52 47
43 37
36 31
31 26
50
50 30
77 77
61 58
49 45
41 36
35 30
30 25
30
50 30
69 69
56 54
45 42
38 34
32 29
28 24
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
1 X 42W Elect. TTT
CONE OF LIGHT
CANDLEPOWER DISTRIBUTION
Candelas
90° Distance FC
DIA
240
75°
480
60°
720
960
45°
1200
0°
15°
30°
06’
08’
10’
12’
14’
16’
18’
20’
31.4
17.7
11.3
7.9
5.8
4.4
3.5
2.8
0.7’
0.9’
1.2’
1.4’
1.6’
1.9’
2.1’
2.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
COEFFICIENT OF UTILIZATION - %
LUMINAIRE
42W Triple Tube, 4pin Ceiling Reflect %
Wall Reflect %
3200
120V 277V 347V RCR
0
Input Watts
48W 48W 50W
2
Operating AMPS
0.41A 0.18A 0.15A
4
Luminaire Efficiency 68%
6
8
Spacing Criteria
0.4
10
Certificate
S0612046R1
Lamp Type
Initial Lumens
80
50 30
80 80
63 58
50 44
41 35
34 29
30 24
50
50 30
74 74
58 55
47 42
39 34
33 28
28 24
30
50 30
66 66
53 51
43 40
36 32
31 27
27 23
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
Instructions for Lamp Position
DIAGRAM FOR
NARROW/WIDE FLOOD ADJUSTMENT
FOR NARROW
FLOOD (N)
26W DTT
42W TTT
FOR WIDE
FLOOD (W)
N
N
N
18W DTT
13W DTT
26W TTT
32W TTT
W
W
26W DTT
42W TTT
13W
18W
26W
32W
DTT
DTT
TTT
TTT
REFLECTOR
523
FLUO
6”
FR6VOW90
90° Wall Wash
FR6VOW90-01
1 x DTT Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90M-05
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
(4 pin) 120-277V
(4 pin) 120-277V
(4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW90-05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90-02MG
524
www.contrastlighting.com
FR6VOW90
1 x DTT Vertical
Technical Specifications
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOMW90
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
95
75°
75°
195
60°
60°
290
45°
45°
385
30°
90°
15°
480
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 77%
Spacing Criteria
0.6 (0-180) 0.8 (90-270)
Certificate
S0806051R1
30°
80
50 30
92 92
75 71
61 55
51 45
43 37
37 31
50
50 30
85 85
71 68
58 54
49 44
41 36
36 31
10
50 30
78 78
66 64
55 52
46 42
39 35
34 30
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
110
75°
75°
220
60°
60°
330
45°
90°
45°
440
30°
15°
550
0°
0°
15°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 70%
Spacing Criteria
1.0 (0-180) 0.9 (90-270)
Certificate
30°
S0806061R1
80
50 30
83 83
66 62
53 48
44 38
37 31
31 26
50
50 30
78 78
63 59
50 46
42 37
35 30
30 26
10
50 30
71 71
58 56
47 44
40 36
34 30
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
155
75°
75°
315
60°
60°
470
45°
90°
45°
625
30°
15°
780
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 82%
Spacing Criteria
0.5 (0-180) 1.1 (90-270)
Certificate
S0804072R1
80
50 30
97 97
76 71
60 53
49 42
41 34
35 29
50
50 30
91 91
71 67
57 52
47 41
39 34
34 28
10
50 30
83 83
66 64
53 49
44 40
38 33
32 28
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
525
FLUO
6”
FR6VOW90
90° Wall Wash
FR6VOW90-01
1 x TTT Vertical
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90M-05
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
DTT
1 X 18W
DTT
1 X 26/32/42W TTT
Base
G24q-1
G24q-2
GX24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
DTT
1 X 18W
DTT
1 X 26/32/42W TTT
Base
G24q-1
G24q-2
GX24q-3/q-4
Volts
(4 pin) 120-277V
(4 pin) 120-277V
(4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW90-05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code.Ex.: F6VOW90-02MG
526
www.contrastlighting.com
FR6VOW90
1 x TTT Vertical
Technical Specifications
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOMW90
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
165
75°
75°
330
60°
60°
500
45°
30°
90°
45°
665
15°
830
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 66%
Spacing Criteria
1.1 (0-180) 1.1 (90-270)
Certificate
S0806101R1
80
50 30
78 78
64 61
53 48
44 39
37 33
32 28
50
50 30
73 73
61 58
51 47
42 38
36 32
31 27
10
50 30
67 67
57 55
48 45
40 37
35 31
30 27
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
200
75°
75°
395
60°
60°
595
45°
30°
90°
45°
790
15°
990
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 69%
Spacing Criteria
1.1 (0-180) 1.1 (90-270)
Certificate
S0806111R1
80
50 30
82 82
66 62
53 48
44 38
37 31
31 26
50
50 30
77 77
62 59
51 46
42 37
35 31
30 26
10
50 30
71 71
58 56
48 44
40 36
34 30
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
300
75°
75°
600
60°
60°
900
45°
90°
45°
1200
30°
15°
1500
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
42W Triple Tube, 4pin
3200
120V 277V 347V
Input Watts
48W
48W 50W
Operating AMPS
0.41A 0.18A 0.15A
Luminaire Efficiency 64%
Spacing Criteria
1.0 (0-180) 1.0 (90-270)
Certificate
S0806117R1
80
50 30
77 77
62 58
50 46
42 37
35 31
31 26
50
50 30
72 72
59 56
48 44
40 36
34 30
30 26
10
50 30
66 66
55 53
45 42
38 35
33 29
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
527
FLUO
6”
FR6VOW90D
90° Doube Wall Wash
FR6VOW90D-01
1 x DTT Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90DM-05
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
Volts
Ballast
L
W
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
(4 pin) 120-277V Electronic 191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
Volts
(4 pin) 120-277V
G24q-1
(4 pin) 120-277V
G24q-2
GX/G24q-3/q-4 (4 pin) 120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW90D-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90D-01MG
528
www.contrastlighting.com
FR6VOW90D
1 x DTT Vertical
Technical Specifications
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOMW90D
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
60
75°
75°
125
60°
60°
185
45°
30°
90°
45°
250
15°
310
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 68%
Spacing Criteria
0.7 (0-180) 1.2 (90-270)
Certificate
S0806121R1
80
50 30
81 81
64 60
51 46
42 36
35 29
30 25
50
50 30
75 75
60 57
49 44
40 35
34 29
29 24
10
50 30
69 69
56 54
46 42
38 34
32 28
27 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
80
75°
75°
160
60°
60°
240
45°
90°
45°
320
30°
15°
400
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 71%
Spacing Criteria
0.6 (0-180) 1.3 (90-270)
Certificate
S0806124R1
80
50 30
84 84
66 61
52 46
42 36
35 29
30 24
50
50 30
78 78
62 58
49 44
40 35
33 28
29 24
10
50 30
72 72
58 55
46 42
38 34
32 28
27 23
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
110
75°
75°
220
60°
60°
325
45°
90°
45°
430
30°
15°
540
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 76%
Spacing Criteria
1.2 (0-180) 1.4 (90-270)
Certificate
S0804073R1
80
50 30
91 91
70 65
54 48
44 37
36 30
31 25
50
50 30
85 85
65 62
51 46
42 36
35 29
29 24
10
50 30
78 78
61 58
48 44
39 35
33 28
28 23
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
529
FLUO
6”
FR6VOW90D
90° Doube Wall Wash
FR6VOW90D-01
1 x TTT Vertical
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W
1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW90DM-05
Housings Specifications
Max 9”
229mm
New Construction (NW)
Code
Lamp
NWF6VU42 1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
(4 pin) 120-277V
Ballast
L
Electronic 191/8”
W
X
H
10”
X
93/16”
X
93/16”
Hole Cut : 63/4”
3/16”
5mm
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4
Volts
(4 pin) 120-277V
Ballast
L
Electronic 143/16”
W
X
H
8”
ø 8”
203mm
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW90D-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW90D-01MG
530
www.contrastlighting.com
Technical Specifications
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
1 x TTT Vertical
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOMW90d
Trims
Plated or painted steel
6”
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
130˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM#283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
FR6VOW90D
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
120
75°
75°
230
60°
60°
350
45°
30°
90°
45°
460
15°
580
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 68%
Spacing Criteria
1.2 (0-180) 1.4 (90-270)
Certificate
S0806125R1
80
50 30
81 81
65 61
52 47
43 37
36 30
30 25
50
50 30
76 76
61 58
49 45
41 36
34 30
29 25
10
50 30
69 69
57 55
47 43
39 35
33 29
28 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
160
75°
75°
320
60°
60°
475
45°
90°
45°
630
30°
15°
790
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 77%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0806128R1
80
50 30
91 91
71 67
56 50
46 39
38 32
32 26
50
50 30
85 85
67 64
54 48
44 38
36 31
31 26
10
50 30
78 78
63 60
50 46
41 37
35 30
30 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
140
75°
75°
285
60°
60°
425
45°
90°
45°
570
30°
15°
710
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
42W Triple Tube, 4pin
3200
120V 277V 347V
Input Watts
48W
48W 50W
Operating AMPS
0.41A 0.18A 0.15A
Luminaire Efficiency 62%
Spacing Criteria
1.4 (0-180) 1.4 (90-270)
Certificate
S08061211R1
80
50 30
73 73
56 52
44 38
35 30
29 24
24 20
50
50 30
69 69
53 50
41 37
33 29
28 23
24 19
10
50 30
63 63
49 47
39 35
31 28
26 22
22 19
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
531
FLUO
6”
FR6VOW120
120° Wall Wash
FR6VOW120-01
1 x DTT Vertical
Damp location
Compact fluorescent: 1 X CFQ-13W
1 X CFQ-18W 1 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW120M-05
Max 9”
229mm
Housings Specifications
New Construction (NW)
Code
NWF6VU13
NWF6VU18
NWF6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
93/16”
93/16”
93/16”
3/16”
5mm
Hole Cut : 63/4”
Remodel
Code
F6VU13
F6VU18
F6VU42
Lamp
1 X 13W
1 X 18W
1 X 26W
DTT
DTT
DTT
Base
G24q-1
G24q-2
G24q-3/q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
143/16”
143/16”
143/16”
X
X
X
ø 8”
203mm
H
8”
8”
8”
X
X
X
93/16”
93/16”
93/16”
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW120-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW120-05MG
532
www.contrastlighting.com
FR6VOW120
1 x DTT Vertical
Technical Specifications
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR6VOMW120
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
90
75°
75°
185
60°
60°
275
45°
30°
90°
45°
370
15°
460
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
13W Quad, 4pin
900
120V 277V 347V
Input Watts
18W
18W 18W
Operating AMPS
0.15A 0.07A 0.06A
Luminaire Efficiency 71%
Spacing Criteria
1.2 (0-180) 1.1 (90-270)
Certificate
S0806052R1
80
50 30
84 84
68 65
56 50
46 40
39 33
33 28
50
50 30
78 78
65 62
53 49
44 40
37 33
32 28
10
50 30
72 72
60 58
50 47
42 38
36 32
31 27
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
105
75°
75°
210
60°
60°
315
45°
30°
90°
45°
415
15°
520
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
18W Quad, 4pin
1200
120V 277V 347V
Input Watts
19W
19W 21W
Operating AMPS
0.16A 0.07A 0.06A
Luminaire Efficiency 71%
Spacing Criteria
1.1 (0-180) 1.0 (90-270)
Certificate
S0806062R1
80
50 30
84 84
67 62
53 47
43 38
36 31
31 26
50
50 30
79 79
63 60
51 46
42 37
35 30
30 25
10
50 30
72 72
59 56
47 44
39 35
33 29
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
150
75°
75°
300
60°
60°
445
45°
90°
45°
595
30°
15°
740
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Quad, 4pin
1710
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 75%
Spacing Criteria
0.5 (0-180) 1.1 (90-270)
Certificate
S0804071R1
80
50 30
90 90
69 64
55 48
44 38
37 31
31 26
50
50 30
84 84
65 62
52 47
42 37
35 30
30 25
10
50 30
77 77
61 58
48 45
40 36
34 29
29 25
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
533
FLUO
6”
FR6VOW120
120° Wall Wash
FR6VOW120-01
1 x TTT Vertical
Damp location
Compact fluorescent: 1 X CFTR-26W
1 X CFTR-32W 1 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR6VOW120M-05
Max 9”
229mm
Housings Specifications
New Construction (NW)
Code
Lamp
NWF6VU42 1 X 26/32/42W TTT
Base
GX24q-3/q-4 (4 pin)
Volts
Ballast
120-277V Electronic
L
W
191/8”
X
H
10”
X
93/16”
Hole Cut : 63/4”
3/16”
5mm
Remodel
Code
F6VU42
Lamp
1 X 26/32/42W TTT
Base
GX24q-3/q-4 (4 pin)
Volts
Ballast
120-277V Electronic
L
W
143/16”
X
H
8”
X
93/16”
ø 8”
203mm
Hole Cut : 63/4”
61/2”
166mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR6VOW120-03
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: F6VOW120-05MG
534
www.contrastlighting.com
FR6VOW120
1 x TTT Vertical
Technical Specifications
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Locking System
Ex.: NWF6VD26S
• Perfect fit to ceiling
• 277V: For dimming capability, change «U» • No light leak
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF6VD26S2
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: F6VU42M
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
6”
FLUO
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
1 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
155
75°
75°
315
60°
60°
470
45°
30°
90°
45°
625
15°
780
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
26W Triple Tube, 4pin
1800
120V 277V 347V
Input Watts
28W
28W 31W
Operating AMPS
0.25A 0.11A 0.09A
Luminaire Efficiency 65%
Spacing Criteria
1.2 (0-180) 1.2 (90-270)
Certificate
S0806102R1
80
50 30
77 77
63 60
52 47
43 38
36 31
31 26
50
50 30
72 72
60 57
49 45
41 37
35 31
30 26
10
50 30
66 66
56 54
47 44
39 36
33 30
29 26
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
200
75°
75°
395
60°
60°
595
45°
30°
90°
45°
795
15°
990
0°
0°
15°
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
32W Triple Tube, 4pin
2400
120V 277V 347V
Input Watts
36W
36W 36W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 73%
Spacing Criteria
1.2 (0-180) 1.2 (90-270)
Certificate
S0806112R1
80
50 30
87 87
69 65
55 50
45 39
38 32
32 27
50
50 30
81 81
65 62
53 48
43 38
36 31
31 26
10
50 30
75 75
61 59
49 46
41 37
35 31
30 26
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
0°
1 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION Candelas
90°
90°
280
75°
75°
560
60°
60°
840
45°
90°
45°
1120
30°
15°
1400
0°
0°
15°
30°
0°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
42W Triple Tube, 4pin
3200
120V 277V 347V
Input Watts
48W
48W 50W
Operating AMPS
0.41A 0.18A 0.15A
Luminaire Efficiency 64%
Spacing Criteria
1.1 (0-180) 1.0 (90-270)
Certificate
S0806118R1
80
50 30
76 76
61 57
49 44
41 36
34 29
30 25
50
50 30
71 71
58 55
47 43
39 35
33 29
29 25
10
50 30
65 65
54 52
44 41
37 34
32 28
28 24
Zonal Cavity Method Effective Floor Cavity
Reflectance 20%
NOTES
535
Compact Fluorescent
Energy Efficient Lighting
7”
FLUO
7”
FR7C
Cross Louver
FR7C-11
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
New Construction (NW)
Code
NWF7U13
NWF7U18
NWF7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
63/16”
157mm
H
10”
10”
10”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 8”
Remodel
Code
F7U13
F7U18
F7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1
G24q-2
G24q-3
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
91/16”
X
63/16”
145/8”
145/8”
X
91/16”
91/16”
X
63/16”
63/16”
X
ø 91/8”
232mm
H
145/8”
X
Hole Cut : 8”
75/8”
194mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR7C-05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR7C-05MG
538
www.contrastlighting.com
FR7C
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF7D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF7D262
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
7”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF7U26EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
125
75°
255
60°
385
510
45°
640
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
13.4
7.5
4.8
3.4
2.5
1.9
1.5
1.2
LUMINAIRE
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
COEFFICIENT OF UTILIZATION - %
Two 13W Quad, 4pin
1800
120V 277V 347V
30W
30W
33W
0.26A 0.11A 0.10A
51.9%
1.4 (0-180) 1.6 (90-270)
S0602163
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
62 62
51 49
43 39
36 32
30 26
26 22
50
50 30
58 58
49 47
41 38
34 31
29 26
25 22
30
50 30
55 55
47 46
40 37
33 31
28 25
24 21
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
135
75°
270
60°
405
540
45°
675
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
15.8
8.9
5.7
3.9
2.9
2.2
1.8
1.4
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 18W Quad, 4pin
2500
120V 277V 347V
Input Watts
35W
35W
38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 51.7%
Spacing Criteria
1.4 (0-180) 1.6 (90-270)
Certificate
S0601183
80
50 30
62 62
51 48
42 38
35 31
29 26
25 21
50
50 30
58 58
48 46
40 37
34 30
28 25
24 21
30
50 30
55 55
47 45
39 36
33 30
28 25
24 21
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
200
75°
400
60°
600
800
45°
1000
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
24.3
13.7
8.8
6.1
4.5
3.4
2.7
2.2
LUMINAIRE
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
COEFFICIENT OF UTILIZATION - %
Two 26W Quad, 4pin
3600
120V 277V 347V
56W
56W
57W
0.47A 0.21A 0.17A
64.5%
1.4 (0-180) 1.9 (90-270)
S0602152
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
77 77
62 59
50 45
41 36
34 29
29 24
50
50 30
72 72
59 56
48 44
39 35
33 28
28 23
30
50 30
69 69
57 55
46 43
38 34
32 28
27 23
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
539
FLUO
7”
FR7O
Downlight
FR7O-11
2 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
2 X CFTR-26W
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR7OM-04
Housings Specifications
New Construction (NW)
Code
NWF7U13
NWF7U18
NWF7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT/TTT
Base
(4 pin)
G24q-1
(4 pin)
G24q-2
GX/G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
63/16”
157mm
H
10”
10”
10”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 8”
Remodel
Code
F7U13
F7U18
F7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT/TTT
Base
(4 pin)
G24q-1
(4 pin)
G24q-2
GX/G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
91/16”
X
63/16”
145/8”
145/8”
X
91/16”
91/16”
X
63/16”
63/16”
X
ø 91/8”
232mm
H
145/8”
X
Hole Cut : 8”
7”
178mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR7O-06
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR7O-11MG
540
www.contrastlighting.com
FR7O
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F7D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F7D182
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to trim code.
Ex: FR70M
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
7”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF7U13EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
130
75°
265
60°
400
525
45°
660
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
13.6
7.7
4.9
3.4
2.5
1.9
1.5
1.2
LUMINAIRE
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
Matte Reflector
Multiplier
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Two 13W Quad, 4pin
1800
120V 277V 347V
30W
30W
33W
0.26A 0.11A 0.10A
64%
1.3 (0-180) 2.0 (90-270)
S0602162
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
76 76
62 59
50 45
41 36
34 29
29 24
50
50 30
71 71
59 56
48 44
39 35
33 28
28 23
0.95
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
30
50 30
68 68
57 55
46 43
38 34
32 28
27 23
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
165
75°
330
60°
500
665
45°
830
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
19.7
11.1
7.1
4.9
3.6
2.8
2.2
1.8
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
Matte Reflector
Multiplier
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Two 18W Quad, 4pin
2500
120V 277V 347V
35W
35W
38W
0.30A 0.13A 0.11A
79.9%
1.7 (0-180) 2.0 (90-270)
S0601182
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
95 95
77 72
62 55
50 43
41 35
34 18
50
50 30
89 89
73 69
59 54
48 42
39 34
33 28
0.95
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
30
50 30
85 85
70 67
57 53
46 42
38 33
32 27
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
190
75°
380
60°
570
760
45°
950
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
22.1
12.5
8.0
5.5
4.1
3.1
2.5
2.0
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Lamp Type
Initial Lumens
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
Matte Reflector
Multiplier
CONE OF LIGHT
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Two 26W Quad, 4pin
3420
120V 277V 347V
56W
56W
57W
0.47A 0.21A 0.17A
51.1%
1.3 (0-180) 1.5 (90-270)
S0602151
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
61 61
51 48
42 38
35 31
30 26
25 22
50
50 30
57 57
48 46
40 37
34 31
29 26
25 22
0.95
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
30
50 30
54 54
46 45
39 37
33 30
28 25
24 21
2 X 26W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
280
75°
560
60°
840
1120
45°
1400
0°
15°
30°
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
34.8
19.6
12.5
8.7
6.4
4.9
3.9
3.1
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificate
Matte Reflector
Multiplier
COEFFICIENT OF UTILIZATION - %
Two 26W Triple, 4pin
3600
120V 277V 347V
56W
56W
57W
0.47A 0.21A 0.17A
65.5%
1.2 (0-180) 1.9 (90-270)
S0704092R1
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
78 78
64 60
52 47
43 38
36 31
30 25
50
50 30
73 73
61 58
50 46
41 37
34 30
29 25
0.95
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
30
50 30
67 67
57 55
47 44
39 36
33 29
28 24
541
FLUO
7”
FR7OLA
2 x DTT Horizontal
FR7OLA-01
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
New Construction (NW)
Code
NWF7U13
NWF7U18
NWF7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
63/16”
157mm
3/16
5mm
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
63/16”
63/16”
63/16”
Hole Cut : 8”
11/2”
37mm
Remodel
Code
F7U13
F7U18
F7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
91/16”
X
63/16”
145/8”
145/8”
X
91/16”
91/16”
X
63/16”
63/16”
X
ø 91/4”
235mm
H
145/8”
X
Hole Cut : 8”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR7OLA-07
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR7OLA-14MG
542
www.contrastlighting.com
FR7OLA
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF7D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF7D262
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
7”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF7D26EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
55
75°
110
60°
165
225
45°
280
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
7.6
4.3
2.7
1.9
1.4
1.1
0.8
0.7
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W
33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 45%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0602231
80
50 30
54 54
41 38
32 28
26 22
21 17
18 14
50
50 30
50 50
38 36
30 27
24 21
20 17
17 14
30
50 30
48 48
37 35
29 26
24 20
20 17
17 14
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
70
75°
140
60°
205
275
45°
340
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
9.3
5.2
3.4
2.3
1.7
1.3
1.0
0.8
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 18W Quad, 4pin
2500
120V 277V 347V
Input Watts
35W
35W
38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 47.5%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0602233
80
50 30
56 55
43 39
33 29
26 22
22 18
18 15
50
50 30
52 52
40 37
31 27
25 21
21 17
17 14
30
50 30
49 49
38 36
29 27
24 21
20 17
17 14
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
100
75°
195
60°
290
385
45°
485
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
13.2
7.4
4.7
3.3
2.4
1.9
1.5
1.2
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 42.1%
Spacing Criteria
1.3 (0-180) 1.4 (90-270)
Certificate
S0602235
80
50 30
50 50
38 35
30 26
24 20
20 16
17 13
50
50 30
47 47
36 34
28 25
23 19
19 16
16 13
30
50 30
45 45
34 33
27 24
22 19
18 15
15 13
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
543
FLUO
7”
FR7OLB
2 x DTT Horizontal
FR7OLB-01
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
New Construction (NW)
Code
NWF7U13
NWF7U18
NWF7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
63/16”
157mm
3/16
5mm
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
10”
10”
10”
X
X
X
63/16”
63/16”
63/16”
Hole Cut : 8”
11/2”
37mm
Remodel
Code
F7U13
F7U18
F7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
91/16”
X
63/16”
145/8”
145/8”
X
91/16”
91/16”
X
63/16”
63/16”
X
ø 91/4”
235mm
H
145/8”
X
Hole Cut : 8”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR7OLB-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR7OLB-02MG
544
www.contrastlighting.com
FR7OLB
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F7D18
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F7D182
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
7”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF7U26EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
85
75°
170
60°
250
340
45°
425
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
9.9
5.6
3.6
2.5
1.8
1.4
1.1
0.9
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 13W Quad, 4pin
1800
120V 277V 347V
Input Watts
30W
30W
33W
Operating AMPS
0.26A 0.11A 0.10A
Luminaire Efficiency 50.7%
Spacing Criteria
1.1 (0-180) 1.5 (90-270)
Certificate
S0602232
80
50 30
60 60
47 44
37 33
30 26
25 21
22 18
50
50 30
56 56
44 42
36 32
29 26
24 21
21 17
30
50 30
54 54
43 41
34 31
28 25
24 21
20 17
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
95
75°
190
60°
285
380
45°
475
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
12.5
7.0
4.5
3.1
2.3
1.8
1.4
1.1
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 18W Quad, 4pin
2500
120V 277V 347V
Input Watts
35W
35W
38W
Operating AMPS
0.30A 0.13A 0.11A
Luminaire Efficiency 52.8%
Spacing Criteria
1.2 (0-180) 1.4 (90-270)
Certificate
S0602234
80
50 30
63 63
49 45
38 34
31 27
26 22
22 18
50
50 30
59 59
46 43
36 33
30 26
25 21
21 18
30
50 30
56 56
44 42
32 32
26 25
21 21
18 17
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
135
75°
270
60°
405
540
45°
675
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
17.1
9.6
6.2
4.3
3.1
2.4
1.9
1.5
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 47.3%
Spacing Criteria
1.2 (0-180) 1.4 (90-270)
Certificate
S0602236
80
50 30
56 56
44 41
35 31
28 24
23 19
20 16
50
50 30
53 53
41 39
33 30
27 23
22 19
19 16
30
50 30
50 50
40 38
32 29
26 23
22 19
19 16
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
545
FLUO
7”
FR7T
Turbo Louver
FR7T-11
2 x DTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-13W
2 X CFQ-18W 2 X CFQ-26W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
New Construction (NW)
Code
NWF7U13
NWF7U18
NWF7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
63/16”
157mm
H
10”
10”
10”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 8”
Remodel
Code
F7U13
F7U18
F7U26
Lamp
2 X 13W DTT
2 X 18W DTT
2 X 26W DTT
Base
G24q-1 (4 pin)
G24q-2 (4 pin)
G24q-3 (4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
91/16”
X
63/16”
145/8”
145/8”
X
91/16”
91/16”
X
63/16”
63/16”
X
ø 9”
230mm
H
145/8”
X
Hole Cut : 8”
75/8”
194mm
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR7T-05
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR7T-05MG
546
www.contrastlighting.com
FR7T
2 x DTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF7D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF7D262
Mounting Bars
• For NW and IC housings.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
7”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF6U18EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 13W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
105
75°
205
60°
315
415
45°
520
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
12.4
7.0
4.5
3.1
2.3
1.7
1.4
1.1
LUMINAIRE
DIA
0.8’
1.1’
1.4’
1.7’
2.0’
2.2’
2.5’
2.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificat
COEFFICIENT OF UTILISATION - %
Two 13W Quad, 4pin
1800
120V 277V 347V
30W
30W
33W
0.26A 0.11A 0.10A
40.1%
1.6 (0-180) 1.7 (90-270)
S0602164
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
48 48
40 38
34 31
28 26
24 21
21 18
50
50 30
45 45
38 37
32 30
27 25
23 21
20 18
30
50 30
43 43
37 36
32 30
27 25
23 21
20 18
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 18W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
120
75°
240
60°
360
480
45°
600
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
14.2
8.2
5.1
3.5
2.6
2.0
1.6
1.3
LUMINAIRE
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificat
COEFFICIENT OF UTILISATION - %
Two 18W Quad, 4pin
2500
120V 277V 347V
35W
35W
38W
0.30A 0.13A 0.11A
39.8%
1.6 (0-180) 1.7 (90-270)
S0601184
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
47 47
39 37
33 30
28 25
23 20
20 17
50
50 30
44 44
37 36
31 29
27 24
23 20
19 17
30
50 30
42 42
36 35
31 29
26 24
22 20
19 17
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
170
75°
340
60°
515
685
45°
860
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
21.0
11.8
7.6
5.2
3.9
2.9
2.3
1.9
LUMINAIRE
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
Lamp Type
Initial Lumens
Input Watts
Operating AMPS
Luminaire Efficiency
Spacing Criteria
Certificat
COEFFICIENT OF UTILISATION - %
Two 26W Quad, 4pin
3600
120V 277V 347V
56W
56W
57W
0.30A 0.13A 0.13A
41.1%
1.6
S0602161
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
80
50 30
49 49
39 39
34 31
29 26
24 21
21 18
50
50 30
46 46
39 37
33 31
28 25
24 21
20 18
30
50 30
44 44
38 36
32 30
27 25
23 21
20 18
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
547
Compact Fluorescent
Energy Efficient Lighting
8”
FLUO
8”
FR8C
Cross Louver
FR8C-11
2 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-26W
2 X CFTR-32W 2 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
63/16”
157mm
New Construction (NW)
Code
NWF8U26
NWF8U32
NWF8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
111/4”
111/4”
111/4”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 91/4”
Remodel
Code
F8U26
F8U32
F8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
151/4”
151/4”
151/4”
X
X
X
107/16”
107/16”
107/16”
X
X
X
ø 103/8”
264mm
ø 81/2”
216mm
H
63/16”
63/16”
63/16”
ø 73/4”
198mm
Hole Cut : 91/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR8C-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR8C-05MG
550
www.contrastlighting.com
FR8C
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F8D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F8D262
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
8”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF8U26EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
205
75°
410
60°
615
820
45°
1025
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
28.3
15.9
10.2
7.1
5.2
4.0
3.1
2.5
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 57.5%
Spacing Criteria
1.2
Certificate
S0602172
80
50 30
69 69
56 53
46 42
38 33
32 27
27 23
50
50 30
64 64
53 51
44 40
36 32
30 27
26 22
30
50 30
61 61
51 50
42 40
35 32
30 26
26 22
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
340
75°
680
60°
1020
1360
45°
1700
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
46.7
26.3
16.8
11.7
8.6
6.6
5.2
4.2
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 32W Triple Tube, 4pin
4800
120V 277V 347V
Input Watts
69W
67W
62W
Operating AMPS
0.58A 0.26A 0.19A
Luminaire Efficiency 67.8%
Spacing Criteria
1.1 (0-180) 1.4 (90-270)
Certificate
S0602212
80
50 30
81 81
67 63
55 50
45 40
38 33
32 27
50
50 30
75 75
63 60
52 48
43 39
37 32
31 27
30
50 30
72 72
61 59
51 47
42 38
36 32
31 27
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
325
75°
650
60°
980
1305
45°
1630
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
44.8
25.2
16.1
11.2
8.2
6.5
5.0
4.0
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 42W Triple Tube, 4pin
6400
120V 277V 347V
Input Watts
91W
90W
80W
Operating AMPS
0.76A 0.32A 0.25A
Luminaire Efficiency 67.4%
Spacing Criteria
1.4 (0-180) 1.5 (90-270)
Certificate
S0602202
80
50 30
80 80
65 62
52 47
43 37
35 30
30 24
50
50 30
75 75
62 59
50 46
41 36
34 29
29 24
30
50 30
72 72
60 57
48 45
40 36
33 29
28 24
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
551
FLUO
8”
FR8O
Downlight
FR8O-11
2 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-26W
2 X CFTR-32W 2 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Matte iridescence free: Add «M» after the trim code. Ex.: FR8OM-06
Housings Specifications
63/16”
157mm
New Construction (NW)
Code
NWF8U26
NWF8U32
NWF8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
111/4”
111/4”
111/4”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 91/4”
Remodel
Code
F8U26
F8U32
F8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
ø 81/2”
216mm
H
151/4”
X
107/16”
X
63/16”
151/4”
151/4”
X
107/16”
107/16”
X
63/16”
63/16”
X
X
ø 103/8”
264mm
ø 73/4”
198mm
Hole Cut : 91/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR8O-08
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR8O-11MG
552
www.contrastlighting.com
FR8O
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF8D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF8D422
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Optional: Low iridescent matte
finish. Add «M» to housing code.
Ex: NWF8U26M
Trims
Plated or painted steel
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
130˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM#283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
8”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF8U32EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
200
75°
405
60°
605
805
45°
1010
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
25.3
14.2
9.1
6.3
4.6
3.6
2.8
2.3
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 67.4%
Spacing Criteria
1.1 (0-180) 1.4 (90-270)
Certificate
S0602171
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Matte Reflector
Multiplier
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
0.95
80
50 30
80 80
65 61
52 47
42 36
35 29
29 24
50
50 30
75 75
61 58
49 45
40 35
33 29
28 24
30
50 30
72 72
59 57
48 44
39 35
33 28
28 24
2 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
340
75°
380
60°
1020
1360
45°
1700
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
43.2
24.3
15.6
10.8
7.9
6.1
4.8
3.9
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Two 32W Triple Tube, 4pin
4800
120V 277V 347V
Input Watts
69W
67W
62W
Operating AMPS
0.58A 0.26A 0.19A
Luminaire Efficiency 73.3%
Spacing Criteria
1.1 (0-180) 1.5 (90-270)
Certificate
S0602211
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Matte Reflector
Multiplier
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
0.95
80
50 30
87 87
71 67
57 52
47 41
39 33
33 28
50
50 30
81 81
67 64
54 50
45 40
37 32
32 27
30
50 30
78 78
65 62
53 49
44 39
37 32
31 27
2 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
325
75°
650
60°
980
1305
45°
1630
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
44.9
25.2
16.2
11.2
8.2
6.3
5.0
4.0
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Two 42W Triple Tube, 4pin
6400
120V 277V 347V
Input Watts
91W
90W
80W
Operating AMPS
0.76A 0.32A 0.25A
Luminaire Efficiency 70.5%
Spacing Criteria
1.2 (0-180) 1.5 (90-270)
Certificate
S0602201
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Matte Reflector
Multiplier
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
0.95
80
50 30
84 84
67 63
53 48
43 37
35 29
30 24
50
50 30
78 78
63 60
51 48
41 36
34 29
29 24
30
50 30
75 75
61 59
49 45
40 35
33 28
28 23
NOTES
553
FLUO
8”
FR8OLA
2 x DTT/TTT Horizontal
FR8OLA-01
Damp location
Compact fluorescent: 2 X CFQ-26W
2 X CFTR-32W 2 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
63/16”
157mm
New Construction (NW)
Code
NWF8U26
NWF8U32
NWF8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
111/4”
111/4”
111/4”
X
X
X
63/16”
63/16”
63/16”
13/8”
35mm
3/16”
5mm
Hole Cut : 91/4”
Remodel
Code
F8U26
F8U32
F8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
107/16”
X
63/16”
151/4”
151/4”
X
107/16”
107/16”
X
63/16”
63/16”
X
ø 101/2”
267mm
H
151/4”
X
Hole Cut : 91/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR8OLA-04
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR8OLA-11MG
554
www.contrastlighting.com
FR8OLA
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: NWF8D26
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: NWF8D262
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
8”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF8D26EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
115
75°
230
60°
345
460
45°
575
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
15.6
8.8
5.6
3.9
2.9
2.2
1.7
1.4
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 49%
Spacing Criteria
1.3
Certificate
S0604191
80
50 30
58 58
44 41
34 30
28 23
23 19
19 15
50
50 30
54 54
41 39
32 29
26 22
22 18
18 15
30
50 30
51 51
40 38
31 28
25 22
21 18
18 15
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
150
75°
305
60°
460
615
45°
770
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
20.4
11.5
7.3
5.1
3.7
2.9
2.3
1.8
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3’
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 32W Triple Tube, 4pin
4800
120V 277V 347V
Input Watts
69W
67W
62W
Operating AMPS
0.58A 0.26A 0.19A
Luminaire Efficiency 52.6%
Spacing Criteria
1.1 (0-180) 1.3 (90-270)
Certificate
S0604195
80
50 30
62 62
49 46
39 34
31 27
26 22
22 18
50
50 30
58 58
46 43
36 33
30 26
25 21
21 18
30
50 30
55 55
44 42
35 32
29 26
24 21
21 18
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
265
75°
465
60°
665
865
45°
1065
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
31.2
17.5
11.2
7.8
5.7
4.4
3.5
2.8
DIA
1.7’
2.3’
2.9’
3.5’
4.0’
4.6’
5.2’
5.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 42W Triple Tube, 4pin
6400
120V 277V 347V
Input Watts
91W
90W
80W
Operating AMPS
0.76A 0.32A 0.25A
Luminaire Efficiency 54.1%
Spacing Criteria
1.2 (0-180) 1.3 (90-270)
Certificate
S0604193
80
50 30
64 64
49 45
38 33
30 25
25 20
21 17
50
50 30
59 59
45 42
35 31
28 24
24 20
20 16
30
50 30
56 56
43 41
34 30
27 24
23 19
19 16
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
555
FLUO
8”
FR8OLB
2 x DTT/TTT Horizontal
FR8OLB-01
Damp location
Compact fluorescent: 2 X CFQ-26W
2 X CFTR-32W 2 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
63/16”
157mm
New Construction (NW)
Code
NWF8U26
NWF8U32
NWF8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
111/4”
111/4”
111/4”
X
X
X
63/16”
63/16”
63/16”
13/8”
35mm
3/16”
5mm
Hole Cut : 91/4”
Remodel
Code
F8U26
F8U32
F8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
X
107/16”
X
63/16”
151/4”
151/4”
X
107/16”
107/16”
X
63/16”
63/16”
X
ø 101/2”
267mm
H
151/4”
X
Hole Cut : 91/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR8OLB-12BR
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR8OLB-06MG
556
www.contrastlighting.com
FR8OLB
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F8D32
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F8D322
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
8”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF8U32EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Trims
Plated or painted steel
Photometric Data
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
154
75°
308
60°
462
616
45°
770
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
21.2
11.9
7.6
5.3
3.9
3
2.4
1.9
DIA
1.4’
1.9’
2.4’
2.9’
3.3’
3.8’
4.3
4.8’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3420
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 52.6%
Spacing Criteria
1.1 (0-180) 1.3 (90-270)
Certificate
S0604192
80
50 30
62 62
49 46
39 34
31 27
26 22
22 18
50
50 30
58 58
46 43
36 33
30 26
25 21
21 18
30
50 30
55 55
44 42
35 32
29 26
24 21
21 18
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
275
75°
550
60°
825
1100
45°
1375
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
37.8
21.3
13.6
9.4
6.9
5.3
4.2
3.4
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 32W Triple Tube, 4pin
4800
120V 277V 347V
Input Watts
69W
67W
62W
Operating AMPS
0.58A 0.26A 0.19A
Luminaire Efficiency 55.4%
Spacing Criteria
0.9 (0-180) 1.3 (90-270)
Certificate
S0604196
80
50 30
66 66
52 49
42 38
34 30
29 24
25 21
50
50 30
61 61
49 47
40 36
33 29
28 24
24 20
30
50 30
58 58
47 45
38 35
32 28
27 23
23 20
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
0
75°
400
60°
800
1200
45°
1600
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
43.3
24.4
15.6
10.8
8.0
6.1
4.8
3.9
DIA
1.0’
1.3’
1.7’
2.0’
2.3’
2.7’
3.0’
3.3’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILIZATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 42W Triple Tube, 4pin
3200
120V 277V 347V
Input Watts
91W
90W
80W
Operating AMPS
0.76A 0.32A 0.25A
Luminaire Efficiency 59.6%
Spacing Criteria
1.0 (0-180) 1.3 (90-270)
Certificate
S0604194
80
50 30
71 71
55 51
43 38
35 30
29 24
25 20
50
50 30
65 65
51 48
41 37
33 29
28 24
24 20
30
50 30
62 62
49 47
39 36
32 28
27 23
23 20
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
557
FLUO
8”
FR8T
Turbo Louver
FR8T-11
2 x DTT/TTT Horizontal
Damp location
Compact fluorescent: 2 X CFQ-26W
2 X CFTR-32W 2 X CFTR-42W
** Lamps must meet ANSI requirements.**
Reflector
Standard: semi-specular low iridescence aluminum
Housings Specifications
63/16”
157mm
New Construction (NW)
Code
NWF8U26
NWF8U32
NWF8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
191/8”
191/8”
191/8”
X
X
X
H
111/4”
111/4”
111/4”
X
X
X
63/16”
63/16”
63/16”
3/16”
5mm
Hole Cut : 91/4”
Remodel
Code
F8U26
F8U32
F8U42
Lamp
2 X 26W
2 X 32W
2 X 42W
DTT
TTT
TTT
Base
G24q-3
GX24q-3
GX24q-4
(4 pin)
(4 pin)
(4 pin)
Volts
120-277V
120-277V
120-277V
Ballast
Electronic
Electronic
Electronic
L
W
151/4”
151/4”
151/4”
X
X
X
H
107/16”
107/16”
107/16”
X
X
X
63/16”
63/16”
63/16”
ø 103/8”
264mm
ø 8”
203mm
Hole Cut : 91/4”
Trim finishes
-01
-02
-03
-04
-04BR
-05
-06
-07
-08
-11
-12BR
-13
-14
-15
-16
White
Black
Gold
Plated 24k
Chrome
Brushed
Chrome
Architectural
Bronze
Antique
Copper
Antique
Brass
Antique
Silver
Matte White
Brushed
Nickel
Satin
Nickel
Almond
Metallic
Grey
Satin
Chrome
Ex.: FR8T-13
For exterior use and Wet Locations, MARINE GRADE treatment is recommended. May be applied on finishes: -01, -02, -05, -06, -11, -14
and -15. See page 576 for more details. Add MG to code. Ex.: FR8T-05MG
558
www.contrastlighting.com
FR8T
2 x DTT/TTT Horizontal
Technical Specifications
Dimming Capability
• 120V: For dimming capability, change «U»
to «D» in codes of housing of 18W to 42W.
Ex.: F8D42
• 277V: For dimming capability, change «U»
to «D» and add «2» at the end of the housing
code of 18W to 42W. Ex: F8D422
Mounting Bars
• For NW.
• Adjustable and lockable from 10” to 24”.
• Lockable integral T-Bar tabs. May be hung
from trusses or suspended ceilings.
Housing Features
• Galvanized steel
• Below ceiling accessible
• Keyhole on socket assembly for
easier installation
• See specs in Housing Section
Locking System
• Perfect fit to ceiling
• No light leak
• Hooks PAT #CAN. 2.088.648
and #USA. 5.377.088
• Take up to 7/8” thick ceilings
Reflector
0.04’’aluminium reflector with
low iridescence semi specular
clear finish.
Trims
Plated or painted steel
Efficient CFL Housings
Socket & Lamp Bases
High temperature-rated
120˚C instead of 90˚C
Listings
• cULus Listed for through branch
wiring and damp location.
1
IC Housings meet:
• Airtight ASTM#283
• State of California Stat Title 24
requirements. Add «W» to code.
Ex: ISF2675RU13W
• City of Chicago
For ceiling air Plenum add «P»
to code. Ex: ISF2675RU13P
8”
FLUO
Emergency Ballast
Available for New Construction housing
(NW) with horizontal lamp only (120-277V).
Add «EM» to housing code.
Ex: NWF8U32EM
Ballast
• 120V through 277V Class P
• HPF Electronic ballast
• 347V HPF Electronic ballast:
Available in Canada.
For ordering change «U» to «3».
• Program start without flickering
• <10% THD and End of life lamp protection
• 5 Year Warranty
Photometric Data
2 X 26W Elect. DTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
170
75°
335
60°
505
675
45°
840
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
22.4
12.6
8.1
5.6
4.1
3.2
2.5
2.0
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILISATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 26W Quad, 4pin
3600
120V 277V 347V
Input Watts
56W
56W
57W
Operating AMPS
0.47A 0.21A 0.17A
Luminaire Efficiency 49.7%
Spacing Criteria
1.5 (0-180) 1.6 (90-270)
Certificat
S0602173
80
50 30
59 55
49 47
40 39
34 32
28 27
24 23
50
50 30
55 55
47 45
39 36
32 29
27 24
23 20
30
50 30
53 53
45 43
38 35
32 29
27 24
23 20
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 32W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
335
75°
675
60°
1015
1350
45°
1690
0°
15°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
39.8
22.4
14.3
9.9
7.3
5.6
4.4
3.6
DIA
1.2’
1.6’
2’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
30°
LUMINAIRE
COEFFICIENT OF UTILISATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 32W Triple Tube, 4pin
4800
120V 277V 347V
Input Watts
69W
67W
62W
Operating AMPS
0.58A 0.26A 0.19A
Luminaire Efficiency 59.2%
Spacing Criteria
1.3 (0-180) 1.5 (90-270)
Certificat
S0602213
80
50 30
71 71
59 56
49 45
41 37
35 30
30 25
50
50 30
66 66
56 54
47 44
39 36
33 30
29 25
30
50 30
63 63
54 53
46 43
38 35
33 29
28 25
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
2 X 42W Elect. TTT
CANDLEPOWER DISTRIBUTION
Candelas
90°
325
75°
650
60°
980
1305
45°
1630
0°
15°
30°
CONE OF LIGHT
Distance
06’
08’
10’
12’
14’
16’
18’
20’
FC
44.8
25.2
16.1
11.2
8.2
6.3
5.0
4.0
DIA
1.2’
1.6’
2.0’
2.4’
2.8’
3.2’
3.6’
4.0’
Beam Edge defined as
50% of Maximum Nadir
Candlepower
LUMINAIRE
COEFFICIENT OF UTILISATION - %
Lamp Type
Initial Lumens
Ceiling Reflect %
Wall Reflect %
RCR
0
2
4
6
8
10
Two 42W Triple Tube, 4pin
6400
120V 277V 347V
Input Watts
91W
90W
80W
Operating AMPS
0.76A 0.32A 0.25A
Luminaire Efficiency 59.5%
Spacing Criteria
1.5 (0-180) 1.5 (90-270)
Certificat
S0602203
80
50 30
71 71
58 55
48 44
39 35
33 28
28 24
50
50 30
66 66
55 53
46 42
38 34
32 28
27 23
30
50 30
63 63
54 52
44 41
37 34
31 28
26 23
Zonal Cavity Method Effective Floor
Cavity Reflectance 20%
NOTES
559
Housing Specifications
Compact Fluorescent
4 6 7 8”
,
,
&
CFL HOUSINGS
4”
REMODEL 4’’
Vertical Compact Fluorescent
PRODUCTS
CODES
F2000
F2000L
F2000U13
F2000313
F2000U18
F2000318
F2000U26
F2000326
F2000D18
F2000D182
F2000D26
F2000D262
F2000LU18
F2000L318
F2000LU26
F2000L326
F2000LU32
F2000L332
F2000LD18
F2000LD182
F2000LD26
F2000LD262
F2000LD32
F2000LD322
HOLE CUT
BALLAST
VOLTAGE
ø 41/4”
Magnetic
HPF
120V
ø 41/4”
Magnetic
HPF
(108mm)
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
(108mm)
Electronic
120V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
347V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
Electronic
120V
120/277V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
347V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
120V
120/277V
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
562
www.contrastlighting.com
LENGTH
13”
WIDTH
51/8”
HEIGHT
SOURCE
4”
13W DTT
(331mm)
(131mm)
(102mm)
153/4”
51/8”
71/4”
(400mm)
(131mm)
(184mm)
139/16”
51/8”
61/16”
13W DTT
13W DTT
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
13W DTT
18W TTT
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
18W TTT
26W TTT
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
26W TTT
18W TTT
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
18W TTT
26W TTT
(345 mm)
(131mm)
(154mm)
139/16”
51/8”
61/16”
26W TTT
18W TTT
(345 mm)
(131mm)
(154mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
18W TTT
26W TTT
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
26W TTT
26W TTT
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
26W TTT
18W TTT
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
18W TTT
26W TTT
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
1311/16”
51/8”
71/4”
(348mm)
(131mm)
(184mm)
26W TTT
26W TTT
26W TTT
BASE
GX23-2
(2 pin)
GX23-2
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(2 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
Continued on next page...
REMODEL 4’’
Vertical Compact Fluorescent
PRODUCTS
CODES
F2575R
F2675R
F2575RU13
F2575R313
F2575RU18
F2575R318
F2575RU26
F2575R326
F2575RD18
F2575RD182
F2575RD26
F2575RD262
F2675RD18
F2675RD182
F2675RD32
F2675RD322
F2675RU13
F2675R313
F2675RU18
F2675R318
F2675RU32
F2675R332
HOLE CUT
BALLAST
VOLTAGE
ø 45/8”
Magnetic
HPF
120V
ø 45/8”
Magnetic
HPF
(118mm)
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
Electronic
120V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
347V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
120V
120/277V
Electronic
Electronic
Electronic
120V
120/277V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
Electronic
347V
120/277V
Electronic
347V
LENGTH
143/8”
WIDTH
59/16”
HEIGHT
SOURCE
6”
13W DTT
(375mm)
(140mm)
(149mm)
143/8”
59/16”
6”
(375mm)
(140mm)
(149mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
13W DTT
13W DTT
13W DTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
18W TTT
18W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
26W TTT
26W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
18W TTT
18W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
26W TTT
26W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
18W TTT
18W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
26W TTT
26W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
13W DTT
13W DTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
18W TTT
18W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
26/32W TTT
26/32W TTT
(361mm)
(141mm)
(180mm)
143/16”
59/16”
71/16”
(361mm)
(141mm)
(180mm)
BASE
GX23-2
CFL HOUSINGS
4”
... continued
(2 pin)
GX23-2
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
563
CFL HOUSINGS
4”
NEW CONSTRUCTION 4’’
Vertical Compact Fluorescent
PRODUCTS
CODES
NW2000LF
NWF2000U13
NWF2000313
NWF2000U18
NWF2000318
NWF2000U26
NWF2000326
NWF2000D18
NWF2000D182
NWF2000D26
NWF2000D262
NWF2000LU18
NWF2000L318
NWF2000LU26
NWF2000L326
NWF2000LU32
NWF2000L332
NWF2000LD18
NWF2000LD182
NWF2000LD26
NWF2000LD262
NWF2000LD32
NWF2000LD322
HOLE CUT
BALLAST
VOLTAGE
ø 41/4”
Magnetic
HPF
120V
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
Electronic
Electronic
Electronic
Electronic
Electronic
41/4”
Electronic
ø 41/4”
Electronic
Dimming
ø 41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
(108mm)
(108mm)
(108mm)
(108mm)
(108mm)
ø 41/4”
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
ø 41/4”
(108mm)
Electronic
Electronic
Electronic
Electronic
Electronic
ø 41/4”
Electronic
ø
41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
ø 41/4”
Electronic
Dimming
ø 41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
(108mm)
(108mm)
(108mm)
(108mm)
(108mm)
(108mm)
(108mm)
120/277V
347V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
120/277V
347V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
120V
277V
LENGTH
1411/16”
WIDTH
10”
HEIGHT
SOURCE
71/4”
13W DTT
(374mm)
(254mm)
(184mm)
1411/16”
10”
6”
13W DTT
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
13W DTT
18W TTT
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
18W TTT
26W TTT
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
26W TTT
18W TTT
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
6”
(374mm)
(254mm)
(153mm)
1411/16”
10”
71/4”
(374mm)
(254mm)
(184mm)
1411/16”
10”
71/4”
(374mm)
1411/16”
(374mm)
1411/16”
(254mm)
(184mm)
10”
71/4”
(254mm)
(184mm)
10”
71/4”
(374mm)
(254mm)
(184mm)
1411/16”
10”
71/4”
(374mm)
(254mm)
(184mm)
1411/16”
10”
71/4”
(374mm)
1411/16”
(374mm)
1411/16”
(254mm)
(184mm)
10”
71/4”
(254mm)
(184mm)
10”
71/4”
(374mm)
(254mm)
(184mm)
1411/16”
10”
71/4”
(374mm)
(254mm)
(184mm)
1411/16”
10”
71/4”
(374mm)
1411/16”
(374mm)
1411/16”
(374mm)
18W TTT
26W TTT
26W TTT
18W TTT
18W TTT
26W TTT
26W TTT
32W TTT
32W TTT
18W TTT
18W TTT
26W TTT
26W TTT
(254mm)
(184mm)
10”
(254mm)
71/4”
(184mm)
32W TTT
10”
71/4”
32W TTT
(254mm)
(184mm)
BASE
GX23-2
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(2 pin)
GX24q-3
(4 pin)
GX24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
Continued on next page...
Emergency ballast available for New Construction housing with horizontal lamps only
(120/277V). Add «EM» to housing code. Ex.: NWF6HU13EM
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
564
www.contrastlighting.com
... continued
Vertical Compact Fluorescent
PRODUCTS
CODES
NW2675F
NWF2575RU13
NWF2575R313
NWF2575RU18
NWF2575R318
NWF2575RU26
NWF2575R326
NWF2575RD18
NWF2575RD182
NWF2575RD26
NWF2575RD262
NWF2675RU13
NWF2675R313
NWF2675RU18
NWF2675R318
NWF2675RU32
HOLE CUT
BALLAST
VOLTAGE
ø 45/8”
Magnetic
HPF
120V
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
Electronic
Electronic
Electronic
Electronic
Electronic
ø
45/8”
Electronic
ø
45/8”
Electronic
Dimming
ø 45/8”
Electronic
Dimming
ø 45/8”
Electronic
Dimming
ø
45/8”
Electronic
Dimming
ø
45/8”
(118mm)
(118mm)
(118mm)
(118mm)
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
ø
45/8”
ø
45/8”
(118mm)
(118mm)
Electronic
Electronic
Electronic
Electronic
Electronic
NWF2675R332
ø 45/8”
(118mm)
Electronic
NWF2675RD18
ø 45/8”
Electronic
Dimming
ø
45/8”
Electronic
Dimming
ø
45/8”
Electronic
Dimming
ø 45/8”
Electronic
Dimming
NWF2675RD182
NWF2675RD32
NWF2675RD322
(118mm)
(118mm)
(118mm)
(118mm)
120/277V
347V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
120V
347V
120V
347V
120V
347V
120V
277V
120V
277V
LENGTH
1411/16”
WIDTH
10”
HEIGHT
SOURCE
6”
13W DTT
(374mm)
(254mm)
(153mm)
1411/16”
10”
75/8”
(374mm)
1411/16”
(374mm)
1411/16”
(254mm)
(194mm)
10”
75/8”
(194mm)
10”
75/8”
18W TTT
18W TTT
(254mm)
(194mm)
1411/16”
10”
75/8”
(374mm)
(254mm)
(194mm)
1411/16”
10”
75/8”
1411/16”
(374mm)
1411/16”
(254mm)
(194mm)
10”
75/8”
10”
75/8”
18W TTT
18W TTT
(254mm)
(194mm)
10”
75/8”
(374mm)
(254mm)
(194mm)
1411/16”
10”
75/8”
(374mm)
1411/16”
(254mm)
(194mm)
10”
75/8”
10”
75/8”
13W DTT
13W DTT
(254mm)
(194mm)
10”
75/8”
(374mm)
(254mm)
(194mm)
1411/16”
10”
75/8”
(374mm)
1411/16”
(254mm)
(194mm)
10”
75/8”
10”
75/8”
26/32W TTT
26/32W TTT
(254mm)
(194mm)
10”
75/8”
(374mm)
(254mm)
(194mm)
1411/16”
10”
75/8”
(374mm)
1411/16”
(254mm)
(194mm)
10”
75/8”
18W TTT
18W TTT
(254mm)
(194mm)
10”
75/8”
26/32W TTT
26/32W TTT
(374mm)
(254mm)
(194mm)
1411/16”
10”
75/8”
(374mm)
18W TTT
(194mm)
1411/16”
1411/16”
18W TTT
(254mm)
(374mm)
(374mm)
26W TTT
(194mm)
1411/16”
1411/16”
26W TTT
(254mm)
(374mm)
(374mm)
26W TTT
(194mm)
1411/16”
1411/16”
26W TTT
(254mm)
(374mm)
(374mm)
13W DTT
(254mm)
(374mm)
(374mm)
13W DTT
(254mm)
(194mm)
BASE
GX23-2
CFL HOUSINGS
NEW CONSTRUCTION 4’’
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(2 pin)
GX24q-3
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
G24q-1
(2 pin)
G24q-1
(2 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
565
CFL HOUSINGS
4”
INSULATED CEILING 4’’
Vertical Compact Fluorescent
PRODUCTS
CODES
ISF2000
ISF2000L
ISF2000U13
ISF2000313
ISF2000U18
ISF2000318
ISF2000D18
ISF2000D182
ISF2000LU18
ISF2000L318
ISF2000LD18
ISF2000LD182
ISF2575R
ISF2675R
ISF2675RU13
ISF2675R313
ISF2675RU18
ISF2675R318
ISF2675RU32
ISF2675R332
ISF2675RD18
ISF2675RD182
ISF2675RD32
ISF2675RD322
HOLE CUT
BALLAST
VOLTAGE
ø 41/4”
Magnetic
HPF
120V
ø 41/4”
Magnetic
HPF
(108mm)
(108mm)
ø 41/4”
(108mm)
ø
41/4”
ø
41/4”
(108mm)
(108mm)
Electronic
Electronic
Electronic
ø 41/4”
Electronic
ø 41/4”
Electronic
Dimming
41/4”
Electronic
Dimming
(108mm)
(108mm)
ø
(108mm)
ø 41/4”
(108mm)
Electronic
ø 41/4”
Electronic
ø
41/4”
Electronic
Dimming
ø
41/4”
Electronic
Dimming
ø 45/8”
Magnetic
HPF
ø 45/8”
Magnetic
HPF
(108mm)
(108mm)
(108mm)
(118mm)
(118mm)
ø
45/8”
ø
45/8”
ø
45/8”
(118mm)
(118mm)
(118mm)
ø 45/8”
(118mm)
ø 45/8”
(118mm)
Electronic
Electronic
Electronic
Electronic
Electronic
ø
45/8”
Electronic
ø
45/8”
Electronic
Dimming
ø 45/8”
Electronic
Dimming
ø 45/8”
Electronic
Dimming
45/8”
Electronic
Dimming
(118mm)
(118mm)
(118mm)
(118mm)
ø
(118mm)
Airtight - ASTM E283
Title 24 - Add «W» to code
Chicago Plenum - «P» to code
566
www.contrastlighting.com
120V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
120V
277V
120V
120V
120/277V
347V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
LENGTH
153/16”
WIDTH
81/8”
HEIGHT
SOURCE
71/2”
13W DTT
(386mm)
(207mm)
(191mm)
153/16”
81/8”
71/2”
(386mm)
(207mm)
(191mm)
193/8”
10”
61/16”
(492mm)
193/8”
(492mm)
193/8”
(179mm)
10”
(254mm)
61/16”
(179mm)
13W DTT
10”
61/16”
18W TTT
(254mm)
(179mm)
193/8”
10”
61/16”
(492mm)
(254mm)
(179mm)
193/8”
10”
61/16”
193/8”
10”
61/16”
18W TTT
18W TTT
(254mm)
(179mm)
10”
61/16”
(492mm)
(254mm)
(179mm)
193/8”
10”
61/16”
(492mm)
193/8”
(254mm)
(179mm)
10”
61/16”
10”
61/16”
18W TTT
13W DTT
(254mm)
(179mm)
10”
61/16”
(386mm)
(254mm)
(179mm)
153/16”
10”
61/16”
(492mm)
193/8”
(492mm)
193/8”
(254mm)
(179mm)
10”
61/16”
10”
(254mm)
61/16”
(179mm)
13W DTT
10”
61/16”
18W TTT
(254mm)
(179mm)
10”
61/16”
(492mm)
(254mm)
(179mm)
193/8”
10”
61/16”
(492mm)
193/8”
10”
(254mm)
61/16”
(179mm)
26/32W TTT
10”
61/16”
18W TTT
(254mm)
(179mm)
10”
61/16”
(492mm)
(254mm)
(179mm)
193/8”
10”
61/16”
(492mm)
26/32W TTT
(179mm)
193/8”
193/8”
18W TTT
(254mm)
(492mm)
(492mm)
13W DTT
(179mm)
193/8”
193/8”
13W DTT
(254mm)
(492mm)
(492mm)
18W TTT
(179mm)
153/16”
193/8”
18W TTT
(254mm)
(492mm)
(386mm)
18W TTT
(179mm)
193/8”
193/8”
18W TTT
(254mm)
(492mm)
(492mm)
13W DTT
(254mm)
(492mm)
(492mm)
13W DTT
(254mm)
(179mm)
10”
61/16”
(254mm)
(179mm)
18W TTT
26/32W TTT
26/32W TTT
BASE
GX23-2
(2 pin)
GX23-2
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX23-2
(2 pin)
GX23-2
(2 pin)
G24q-1
(4 pin)
G24q-1
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
GX24q-2
(4 pin)
GX24q-2
(4 pin)
GX24q-3
(4 pin)
GX24q-3
(4 pin)
• Insulated Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
REMODEL 6’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
F6HU13
F6H313
F6HU13S
F6H313S
F6HU18
F6H318
F6HU18S
F6H318S
F6HU26
F6H326
F6HU26S
F6H326S
F6HU32S
F6H332S
F6HD18
F6HD182
F6HD18S
F6HD18S2
F6HD26
F6HD262
F6HD26S
F6HD26S2
F6HD32S
F6HD32S2
HOLE CUT
ø
63/4”
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø
63/4”
ø
63/4”
(172mm)
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø
63/4”
ø
63/4”
(172mm)
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
BALLAST
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
120/277V
347V
120/277V
347V
120/277V
347V
120/277V
Electronic
Electronic
(172mm)
347V
Electronic
ø 63/4”
(172mm)
120/277V
Electronic
ø
(172mm)
347V
Electronic
63/4”
(172mm)
120/277V
141/8”
Electronic
ø
(172mm)
LENGTH
Electronic
63/4”
(172mm)
VOLTAGE
Electronic
347V
120/277V
347V
120V
277V
120V
277V
120V
277V
120V
277V
120V
277V
WIDTH
HEIGHT
SOURCE
BASE
8”
73/16”
2 X 13W
DTT
G24q-1
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 X 13W
DTT
G24q-1
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 13W
DTT
G24q-1
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 13W
DTT
G24q-1
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 X 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 X 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 X 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 X 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 32W
TTT
GX24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 X 32W
TTT
GX24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 x 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 x 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 x 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 x 18W
DTT
G24q-2
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 x 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
2 x 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 x 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 x 26W
DTT
G24q-3
(4 pin)
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
1 x 32W
TTT
GX24q-3
1 x 32W
TTT
GX24q-3
(359mm)
(204mm)
(183mm)
141/8”
8”
73/16”
(359mm)
(204mm)
(183mm)
CFL HOUSINGS
6”
(4 pin)
(4 pin)
(4 pin)
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
567
CFL HOUSINGS
6”
NEW CONSTRUCTION 6’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
NWF6HU13
NWF6H313
NWF6HU13S
NWF6H313S
NWF6HU18
NWF6H318
NWF6HU18S
NWF6H318S
NWF6HU26
NWF6H326
NWF6HU26S
NWF6H326S
NWF6HU32S
NWF6H332S
NWF6HD18
NWF6HD182
NWF6HD18S
NWF6HD18S2
NWF6HD26
NWF6HD262
NWF6HD26S
NWF6HD26S2
NWF6HD32S
NWF6HD32S2
HOLE CUT
ø
63/4”
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø
63/4”
ø
63/4”
(172mm)
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
ø
63/4”
ø
63/4”
(172mm)
(172mm)
ø 63/4”
(172mm)
ø 63/4”
(172mm)
BALLAST
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
Electronic
ø
63/4”
ø
63/4”
Electronic
ø 63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø
63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
ø 63/4”
Electronic
Dimming
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
Electronic
VOLTAGE
LENGTH
120/277V
191/8”
347V
120/277V
347V
120/277V
347V
120/277V
347V
120/277V
347V
120/277V
347V
120/277V
347V
120V
277V
120V
277V
120V
277V
120V
277V
120V
277V
WIDTH
HEIGHT
SOURCE
BASE
10”
73/16”
2 X 13W
DTT
G24q-1
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
2 X 13W
DTT
G24q-1
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 13W
DTT
G24q-1
568
www.contrastlighting.com
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 13W
DTT
G24q-1
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
2 X 18W
DTT
G24q-2
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
2 X 18W
DTT
G24q-2
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 18W
DTT
G24q-2
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 18W
DTT
G24q-2
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
2 X 26W
DTT
G24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
2 X 26W
DTT
G24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 26W
DTT
G24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 26W
DTT
G24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 32W
TTT
GX24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
191/8”
10”
73/16”
1 X 32W
TTT
GX24q-3
(4 pin)
(486mm)
(254mm)
(183mm)
173/16”
81/2”
73/16”
2 x 18W
DTT
G24q-2
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
2 x 18W
DTT
G24q-2
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
1 x 18W
DTT
G24q-2
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
1 x 18W
DTT
G24q-2
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
2 x 26W
DTT
G24q-3
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
2 x 26W
DTT
G24q-3
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
1 x 26W
DTT
G24q-3
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
1 x 26W
DTT
G24q-3
(4 pin)
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
1 x 32W
TTT
GX24q-3
1 x 32W
TTT
GX24q-3
(437mm)
(216mm)
(183mm)
173/16”
81/2”
73/16”
(437mm)
(216mm)
(183mm)
Emergency ballast available for New Construction housing with horizontal lamps only
(120/277V). Add «EM» to housing code. Ex.: NWF6HU13EM
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
(4 pin)
(4 pin)
(4 pin)
(4 pin)
REMODEL 6’’
Vertical Compact Fluorescent
PRODUCTS
CODES
F6VU13
F6V313
F6VU18
F6V318
F6VU42
F6V342
F6VD18
F6VD182
F6VD42
F6VD422
HOLE CUT
BALLAST
VOLTAGE
ø 63/4”
Electronic
120/277V
ø 63/4”
Electronic
347V
ø 63/4”
Electronic
120/277V
(172mm)
(172mm)
(172mm)
ø
63/4”
(172mm)
Electronic
347V
ø 63/4”
Electronic
120/277V
ø 63/4”
Electronic
347V
ø 63/4”
Electronic
120V
ø 63/4”
Electronic
277V
ø 63/4”
Electronic
120V
ø 63/4”
Electronic
277V
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
(172mm)
LENGTH
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
143/16”
(360mm)
WIDTH
8”
(165mm)
8”
(165mm)
8”
HEIGHT
SOURCE
BASE
93/16”
1 X 13W DTT
G24q-1 (4 pin)
93/16”
1 X 13W DTT
G24q-1 (4 pin)
(204mm)
(233mm)
(165mm)
(233mm)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
8”
93/16”
1 X 18W DTT
G24q-2 (4 pin)
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
(165mm)
8”
(165mm)
8”
(165mm)
8”
(165mm)
8”
(165mm)
8”
(165mm)
8”
(165mm)
(233mm)
93/16”
(233mm)
93/16”
(233mm)
(233mm)
(233mm)
93/16”
(233mm)
93/16”
(233mm)
CFL HOUSINGS
6”
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
569
CFL HOUSINGS
6”
NEW CONSTRUCTION 6’’
Vertical Compact Fluorescent
PRODUCTS
CODES
HOLE CUT
63/4”
BALLAST
VOLTAGE
LENGTH
120/277V
191/8”
NWF6VU13
ø
(172mm)
NWF6V313
ø 63/4”
(172mm)
Electronic
347V
NWF6VU18
ø 63/4”
(172mm)
Electronic
120/277V
63/4”
Electronic
NWF6V318
ø
(172mm)
Electronic
347V
NWF6VU42
ø 63/4”
(172mm)
Electronic
120/277V
NWF6V342
ø 63/4”
(172mm)
Electronic
347V
NWF6VD18
ø 63/4”
(172mm)
Electronic
Dimming
120V
NWF6VD182
ø 63/4”
(172mm)
Electronic
Dimming
277V
NWF6VD42
ø 63/4”
(172mm)
Electronic
Dimming
120V
NWF6VD422
ø 63/4”
(172mm)
Electronic
Dimming
277V
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
570
www.contrastlighting.com
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
WIDTH
HEIGHT
SOURCE
BASE
(254mm)
10”
93/16”
(233mm)
1 X 13W DTT
G24q-1 (4 pin)
10”
93/16”
1 X 13W DTT
G24q-1 (4 pin)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
(254mm)
10”
(254mm)
10”
(254mm)
10”
(254mm)
10”
(254mm)
(233mm)
(233mm)
93/16”
(233mm)
93/16”
(233mm)
(486mm)
(254mm)
(233mm)
93/16”
1 X 18W DTT
G24q-2 (4 pin)
191/8”
10”
93/16”
1 X 18W DTT
G24q-2 (4 pin)
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
1 X 26W DTT
1 X 26/32W TTT
1 X 42W TTT
G24q-3 (4 pin)
GX24q-3 (4 pin)
GX24q-4 (4 pin)
(486mm)
191/8”
(486mm)
191/8”
(486mm)
10”
(233mm)
(254mm)
10”
(254mm)
10”
(254mm)
(233mm)
93/16”
(233mm)
93/16”
(233mm)
REMODEL 7’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
HOLE CUT
BALLAST
VOLTAGE
F7U13
ø 8”
(203mm)
Electronic
120/277V
F7313
ø 8”
(203mm)
F7U18
ø 8”
(203mm)
F7318
ø 8”
(203mm)
Electronic
347V
F7U26
ø 8”
(203mm)
Electronic
120/277V
F7326
ø 8”
(203mm)
Electronic
F7D18
ø 8”
(203mm)
Electronic
Dimming
F7D182
ø 8”
(203mm)
Electronic
Dimming
277V
F7D26
ø 8”
(203mm)
Electronic
Dimming
120V
F7D262
ø 8”
(203mm)
Electronic
Dimming
Electronic
Electronic
347V
120/277V
347V
120V
277V
LENGTH
145/8”
WIDTH
91/16”
HEIGHT
SOURCE
BASE
(372mm)
(231mm)
(157mm)
63/16”
2 X 13W DTT
G24q-1 (4 pin)
145/8”
91/16”
63/16”
(372mm)
(231mm)
(157mm)
2 X 13W DTT
G24q-1 (4 pin)
145/8”
91/16”
63/16”
(372mm)
(231mm)
(157mm)
2 X 18W DTT
G24q-2 (4 pin)
145/8”
91/16”
63/16”
2 X 18W DTT
G24q-2 (4 pin)
(372mm)
145/8”
(231mm)
91/16”
(157mm)
(372mm)
(231mm)
(157mm)
63/16”
2 X 26W DTT
G24q-3 (4 pin)
145/8”
91/16”
63/16”
(372mm)
(231mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
145/8”
91/16”
63/16”
(372mm)
(231mm)
(157mm)
2 X 18W DTT
G24q-1 (4 pin)
145/8”
91/16”
63/16”
2 X 18W DTT
G24q-2 (4 pin)
(372mm)
145/8”
(231mm)
(372mm)
(231mm)
(157mm)
63/16”
2 X 26W DTT
G24q-3 (4 pin)
145/8”
91/16”
63/16”
2 X 26W DTT
G24q-3 (4 pin)
WIDTH
HEIGHT
SOURCE
BASE
(254mm)
10”
63/16”
(157mm)
2 X 13W DTT
G24q-1 (4 pin)
10”
63/16”
(372mm)
91/16”
(157mm)
(231mm)
(157mm)
CFL HOUSINGS
7”
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
NEW CONSTRUCTION 7’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
HOLE CUT
NWF7U13
ø 8”
(203mm)
NWF7313
ø 8”
(203mm)
NWF7U18
ø 8”
(203mm)
Electronic
120/277V
NWF7318
ø 8”
(203mm)
Electronic
347V
NWF7U26
ø 8”
(203mm)
NWF7326
ø 8”
(203mm)
Electronic
NWF7D18
ø 8”
(203mm)
Electronic
Dimming
120V
NWF7D182
ø 8”
(203mm)
Electronic
Dimming
277V
NWF7D26
ø 8”
(203mm)
Electronic
Dimming
NWF7D262
ø 8”
(203mm)
Electronic
Dimming
BALLAST
Electronic
Electronic
Electronic
VOLTAGE
LENGTH
120/277V
191/8”
347V
120/277V
347V
120V
277V
(486mm)
191/8”
(486mm)
(254mm)
(157mm)
2 X 13W DTT
G24q-1 (4 pin)
191/8”
10”
63/16”
2 X 18W DTT
G24q-2 (4 pin)
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
(254mm)
10”
(157mm)
(254mm)
(157mm)
63/16”
2 X 18W DTT
G24q-2 (4 pin)
(254mm)
10”
63/16”
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
10”
63/16”
(486mm)
(254mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
191/8”
10”
63/16”
2 X 18 W DTT
G24q-1 (4 pin)
(486mm)
191/8”
(486mm)
191/8”
(486mm)
191/8”
(486mm)
(254mm)
10”
(157mm)
(254mm)
(157mm)
63/16”
2 X 18W DTT
G24q-2 (4 pin)
(254mm)
10”
63/16”
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
10”
63/16”
2 X 26W DTT
G24q-3 (4 pin)
(254mm)
(157mm)
Emergency ballast available for New Construction housing with horizontal lamps only
(120/277V). Add «EM» to housing code. Ex.: NWF7D182EM
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
571
CFL HOUSINGS
8”
REMODEL 8’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
HOLE CUT
BALLAST
VOLTAGE
F8U26
ø 91/4”
(235mm)
Electronic
120/277V
F8326
91/4”
ø
(235mm)
Electronic
347V
F8U32
ø
(235mm)
F8332
ø 91/4”
(235mm)
Electronic
347V
F8U42
ø 91/4”
(235mm)
Electronic
120/277V
F8342
91/4”
91/4”
ø
(235mm)
120/277V
Electronic
ø
(235mm)
Electronic
Dimming
F8D262
ø 91/4”
(235mm)
Electronic
Dimming
277V
F8D32
ø 91/4”
(235mm)
Electronic
Dimming
120V
91/4”
ø
(235mm)
Electronic
Dimming
91/4”
120V
277V
F8D42
ø
(235mm)
Electronic
Dimming
120V
F8D422
ø 91/4”
(235mm)
Electronic
Dimming
277V
• Remodel Housings accept 7/8” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
572
347V
F8D26
F8D322
91/4”
Electronic
www.contrastlighting.com
LENGTH
151/4”
WIDTH
107/16”
HEIGHT
SOURCE
BASE
(388mm)
(266mm)
(157mm)
63/16”
2 X 26W DTT
G24q-3 (4 pin)
151/4”
107/16”
63/16”
(388mm)
(266mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
151/4”
107/16”
63/16”
(388mm)
(266mm)
(157mm)
2 X 32W TTT
GX24q-3 (4 pin)
151/4”
107/16”
63/16”
2 X 32W TTT
GX24q-3 (4 pin)
(388mm)
151/4”
(266mm)
107/16”
(157mm)
(388mm)
(266mm)
(157mm)
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
151/4”
107/16”
63/16”
(388mm)
(266mm)
(157mm)
2 X 42W TTT
GX24q-4 (4 pin)
151/4”
107/16”
63/16”
(388mm)
(266mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
151/4”
107/16”
63/16”
2 X 26W DTT
G24q-3 (4 pin)
(388mm)
151/4”
(266mm)
107/16”
(157mm)
(388mm)
(266mm)
(157mm)
63/16”
2 X 32W TTT
GX24q-3 (4 pin)
151/4”
107/16”
63/16”
(388mm)
(266mm)
(157mm)
2 X 32W TTT
GX24q-3 (4 pin)
151/4”
107/16”
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
(388mm)
151/4”
(388mm)
(266mm)
107/16”
(266mm)
(157mm)
(157mm)
NEW CONSTRUCTION 8’’
Horizontal Compact Fluorescent
PRODUCTS
CODES
HOLE CUT
BALLAST
VOLTAGE
NWF8U26
ø 91/4”
(235mm)
Electronic
120/277V
NWF8326
ø 91/4”
(235mm)
Electronic
347V
Electronic
120/277V
NWF8U32
91/4”
ø
(235mm)
NWF8332
ø
(235mm)
NWF8U42
ø 91/4”
(235mm)
Electronic
120/277V
NWF8342
ø 91/4”
(235mm)
Electronic
347V
NWF8D26
91/4”
ø
(235mm)
Electronic
91/4”
Electronic
Dimming
91/4”
347V
120V
NWF8D262
ø
(235mm)
Electronic
Dimming
NWF8D32
ø 91/4”
(235mm)
Electronic
Dimming
120V
NWF8D322
ø 91/4”
(235mm)
Electronic
Dimming
277V
NWF8D42
NWF8D422
91/4”
ø
(235mm)
Electronic
Dimming
91/4”
Electronic
Dimming
ø
(235mm)
277V
120V
277V
LENGTH
191/8”
(486mm)
191/8”
(486mm)
191/8”
WIDTH
141/8”
(359mm)
141/8”
(359mm)
141/8”
HEIGHT
SOURCE
BASE
63/16”
2 X 26W DTT
G24q-3 (4 pin)
63/16”
2 X 26W DTT
G24q-3 (4 pin)
(157mm)
(157mm)
(486mm)
(359mm)
(157mm)
63/16”
2 X 32W TTT
GX24q-3 (4 pin)
191/8”
141/8”
63/16”
(486mm)
(359mm)
(157mm)
2 X 32W TTT
GX24q-3 (4 pin)
191/8”
141/8”
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
(486mm)
191/8”
(359mm)
141/8”
(157mm)
(486mm)
(359mm)
(157mm)
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
191/8”
141/8”
63/16”
(486mm)
(359mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
191/8”
141/8”
63/16”
(486mm)
(359mm)
(157mm)
2 X 26W DTT
G24q-3 (4 pin)
191/8”
141/8”
63/16”
2 X 32W TTT
GX24q-3 (4 pin)
(486mm)
191/8”
(359mm)
141/8”
(157mm)
(486mm)
(359mm)
(157mm)
63/16”
2 X 32W TTT
GX24q-3 (4 pin)
191/8”
141/8”
63/16”
2 X 42W TTT
GX24q-4 (4 pin)
2 X 42W TTT
GX24q-4 (4 pin)
(486mm)
(359mm)
(157mm)
191/8”
141/8”
63/16”
(486mm)
(359mm)
(157mm)
CFL HOUSINGS
8”
Emergency ballast available for New Construction housing with horizontal lamps only
(120/277V). Add «EM» to housing code. Ex.: NWF8D262EM
• New Construction Housings accept 1 1/2” ceiling thickness.
• Below Ceiling Accessibility
• Thermally Protected Housings
573
Parts and Accessories
Compact Fluorescent
4 6 7 8”
,
,
&
Parts & Accessories
Shower Lenses
For compact fluorescent 4”
shower trims.
LENSES
Lenses for compact
fluorescent 4”
(110mm)
Clear / convex
312648
Frosted / convex
312649
Clear
103099
*Frosted
103100
Frosted / clear center
103101
*Frosted lens is factory installed. The other lenses are sold separately.
Marine Grade Treatment
Available for Contrast trims.
This treatment is offered with our trim collection of finishes -01, -02, -05, -06, -11, -14 and -15. Unless
otherwise indicated, all trim series are for interior use only. For exterior use, «Marine Grade» treatment is
recommended. This procedure increases rust resistance up to 5 times more than the untreated galvanized
steel. Furtermore, the high temperature powder coated paint process provides a durable finish.
The «Marine Grade» treatment is recommended for very high level humidity locations and is particularly
efficient in high salinity areas such as coastal regions. It may be used for outdoors such as soffits and
porches, or for indoors, in high humidity or wet areas such as spas, saunas, showers, pool, etc. This
treatment is offered with a Contrast limited warranty of two (2) years.
576
www.contrastlighting.com
Parts & Accessories
Ballast
For Fluorescent.
Electronic Ballast
CODE
100744
100746
100742
100743
100745
100750
DESCRIPTION
120-277V 1 X 13W BES
Electronic
120-277V 2 X 13W BES
Electronic
120-277V 1 X 18W BES
Electronic
120-277V 2 X 18W BES
Electronic
120-277V 1 X 26/32/42W BES
Electronic
120-277V 2 X 26W BES
Electronic
347V 1 X 13W BES
Electronic
347V 2 X 13W BES
Electronic
347V 1 X 18W BES
Electronic
347V 2 X 18W BES
Electronic
347V 1 X 26/32/42W BES
Electronic
347V 2 X 26W BES
Electronic
100749
120-277V 2 X 26/32/42W BES
Electronic
100747
347V 2 X 26/32/42W BES
Electronic
CODE
DESCRIPTION
101278
DIM 120V
1 X 18W BES
DIM 277V
101289
Electronic Dimmable
101279
DIM 120V
2 X 18W BES
DIM 277V
101281
Electronic Dimmable
101286
DIM 120V
2 X 26W BES
DIM 277V
101283
Electronic Dimmable
101138
DIM 120V
2 X 26W BES
1 X 26/32/42W BES
DIM 277V
101280
1 X 26/32/42W BES
Electronic Dimmable
101287
DIM 120V
2 X 32/42W BES
DIM 277V
101284
Electronic Dimmable
CODE
DESCRIPTION
101308
Hi Power Factor 120V 13W
CODE
DESCRIPTION
306997
120/277V 60HZ
Dimmable Ballast
Magnetic Ballast
Magnetic
Emergency Ballast
Electronic
577
Energy Star
Energy Star
R
Qualified Fixtures
4”
Housings
F2000U13
F2675RU13
F2000LU18
F2575RU13
F2000U18
F2675RU18
F2000LU26
F2575RU18
F2000U26
F2675RU26
NWF2000LU18
F2575RU26
NWF2000U13
F2675RU32
NWF2000LU26
NWF2575RU13
NWF2000U18
NWF2675RU13
NWF2000LD26
NWF2575RU18
NWF2000U26
NWF2675RU18
NWF2575RU26
NWF2000D26
NWF2675RU26
NWF2575RD26
NWF2675RD26
NWF2675RU32
combined with
combined with
combined with
NWF2675RD32
Trims
A2000V
FB2675
A2400S
A2000VL
FC2675
A2401S
A2000VLS
A2450S
A2000VS
A2451S
A2010V
F2450VT
A2010VL
A2010VLS
A2010VS
578
www.contrastlighting.com
Energy Star
6”
Housings
7”
Housings
F6HD26S
F6VU13
F6HD32S
F6VU18
F7U13
F7U18
F6HU13
F6VU26
F7U26
F6HU13S
F6VU32
NWF7U13
F6HU18
F6VU42
NWF7U18
F6HU18S
NWF6VU13
NWF7U26
F6HU26
NWF6VU18
F6HU26S
NWF6VU42
8”
Housings
F8U26
NWF8U26
Energy Star
Qualified Fixtures
F6HU32S
NWF6HD26S
NWF6HD32S
NWF6HU13
NWF6HU13S
NWF6HU26S
NWF6HU32S
Trims
combined with
NWF6HU26
combined with
NWF6HU18S
combined with
combined with
NWF6HU18
Trims
Trims
FR6HO
FR6VO
FR7C
FR8C
FR6HOLA
FR6VOLA
FR7O
FR8O
FR6HOLB
FR6VOLB
FR7OLA
FR8OLA
FR6HOM
FR6VOW120
FR7OLB
FR8OLB
FR6HOW120
FR6VOW90
FR7OM
FR8OM
FR6HOW90
FR6VOW90D
FR7T
FR8T
FR6HOMW120
FR6VOM
FR6HOMW90
FR6VOMW120
FR6VOMW90
FR6VOMW90D
579
Download