SPP Pumps Inc. Atlanta All rights reserved by SPP Pumps Ltd UL Listed, FM Approved Fire Pump Sets – Horizontal Split Case Pumps • Flows from 200-5000 US GPM – Vertical Turbine • Flows to 5000 US GPM – In-Line Pumps • Flows to 750 US GPM – End Suction • Flows to 1500 US GPM – Residential 13D • Flows to 70 US GPM All rights reserved by SPP Pumps Ltd What’s new and coming up… Grooved end jockey pumps – Already standard Grooved increasers standard with NBG packs – – New standard Class 250# flanges Grooved fire pumps – Spring 2013 All rights reserved by SPP Pumps Ltd Types of Fire Pumps Split Case Fire Pumps Inline Fire Pumps Vertical Turbine Fire Pumps End Suction Fire Pumps Residential 13D Fire pumps All rights reserved by SPP Pumps Ltd Everything you need to know about fire pumps…. All rights reserved by SPP Pumps Ltd Types of Fire Pumps All rights reserved by SPP Pumps Ltd HORIZONTAL SPLIT CASE ELECTRIC All rights reserved by SPP Pumps Ltd HORIZONTAL SPLIT CASE DIESEL All rights reserved by SPP Pumps Ltd Split Case Fire Pump Models • • • • Ease of Installation and Maintenance Longevity and Durability Serviceability Reliability • • • • • • Typical applications Warehouse Hospital Manufacturing plant University or large school Office High Rise All rights reserved by SPP Pumps Ltd VERTICAL INLINE (ELECTRIC ONLY) All rights reserved by SPP Pumps Ltd Vertical In-Line Requires less space than split case pump of the same capacity Typically Less expensive Motor can be serviced without disconnecting suction & discharge flanges from piping Typical applications Small schools Churches Parking garages All rights reserved by SPP Pumps Ltd END SUCTION ELECTRIC All rights reserved by SPP Pumps Ltd END SUCTION DIESEL All rights reserved by SPP Pumps Ltd VERTICAL TURBINE ELECTRIC All rights reserved by SPP Pumps Ltd VERTICAL TURBINE DIESEL All rights reserved by SPP Pumps Ltd Vertical Turbine Fire Pumps All rights reserved by SPP Pumps Ltd Vertical Turbine Design Features No priming Adaptability to water level Adaptability to various driver combinations Compact “footprint” No alignment necessary Minimal maintenance All rights reserved by SPP Pumps Ltd Vertical Turbine Applications Vertical Turbines Applications where city water is not available Ponds and lakes to utilize water supply Only pump approved for suction lift conditions All rights reserved by SPP Pumps Ltd 90% rule… 90% of what drives a pump quote is? Flow Pressure All rights reserved by SPP Pumps Ltd Electric or Diesel? Electric sets are typically used where there is a reliable source of power What to ask.. – What voltage? • – 208? 230? 460? Transfer Switch? • Transfer switch is used when the source of power may not be reliable and/or precaution. – Transfer switch for 2nd utility – Starting method? • Full voltage? – across the line • Reduced Voltage? – Part winding – Primary reactor – Wye Delta Open – Wye Delta closed – Soft Start – Auto Transformer That’s all you need to know……. See rapid All rights reserved by SPP Pumps Ltd Typical Brands of Fire Pump Controllers – – – – – – Firetrol Master Metron Cutler Hammer Joslyn Clarke Tornatech All rights reserved by SPP Pumps Ltd Electric motors Electric motors are used to drive – – – – Horizontal split case End suction Vertical inline Vertical turbine Motors are selected based on – – – – Voltage HP required by the pump Frame size Configuration of pump (i.e. vertical or horizontal) All rights reserved by SPP Pumps Ltd Typical Brands of Electric Motors – – – – WEG Motors US Electric Motors Marathon GE All rights reserved by SPP Pumps Ltd Why Diesel? Diesel units are used primarily where there is not a reliable source of power or by preference Typical Engine Manufacturers – Clarke engines (John Deere) – Cummins – Caterpiller Diesel units may drive – Horizontal split case – Vertical turbine – End suction Engines are selected based on – HP of pump requirement – RPM – EPA emissions standards as stated on presentation below All rights reserved by SPP Pumps Ltd Diesel controllers Diesel engine fire pumps are especially nice because of how reliable they can be and by the inexpensive control panel. There are only a few options tend to be required on diesel control panels. The most distinct difference is voltage of the battery used to back up the engine – 12 volt DC? – 24 volt DC? All rights reserved by SPP Pumps Ltd What is a jockey pump? A jockey pump is a pressure maintenance pump set so that in the event of slight fluctuations in sprinkler system pressure, the fire pump will not need to turn on. Typically set 10 psi over the fire pump Jockey pumps are replaced frequently and can be purchased from you…. What to ask? In order to sell a jockey pump, you will need to know. If the customer is replacing a jockey pump, you will at least need to know the following – – – Boost pressure (can be found by adding at least 10 psi to the fire pump pressure setting HP (should be on the motor nameplate or jockey pump controller) Voltage (also on motor nameplate or jockey pump controller) All rights reserved by SPP Pumps Ltd Jockey Pumps Regenerative Turbine Pumps Vertical Multi-stage All rights reserved by SPP Pumps Ltd Jockey pump controller Jockey pump controllers very small and meant to supply power exclusively to the jockey pump All rights reserved by SPP Pumps Ltd Fire pump accessories and NFPA 20 NFPA 20 suggests minimum pipe and accessory sizes based on flow. In the chart below, you can see how based on the flow, you can select what size flow meter you might need, what size suction and discharge pipe is needed and what size test header etc… Thought you do not need to memorize this chart, it is a helpful tool…. All rights reserved by SPP Pumps Ltd Fire Pump Standards NFPA-20 Minimum Pipe Sizes For Fire Systems Based on NFPA-20, 1996 Edition Pump Rating in Suction GPM In. 25 1 50 1-1/2 100 2 150 2-1/2 200 3 250 3-1/2 300 4 400 4 450 5 500 5 750 6 1000 8 1250 8 1500 8 2000 10 2500 10 3000 12 3500 12 4000 14 Discharge In. 1 1-1/4 2 2-1/2 3 3 4 4 5 5 6 6 8 8 10 10 12 12 12 Relief Valve In. 3/4 1-1/4 1-1/2 2 2 2 2-1/2 3 3 3 4 4 6 6 6 6 8 8 8 Relief Valve Discharge In. 1 1-1/2 2 2-1/2 2-1/2 2-1/2 3-1/2 5 5 5 6 8 8 8 10 10 12 12 14 Meter Number and Size of Hose Device In. Valves In. 1-1/4 (1) 1-1/2 2 (1) 1-1/2 2-1/2 (1) 2-1/2 3 (1) 2-1/2 3 (1) 2-1/2 3-1/2 (1) 2-1/2 3-1/2 (1) 2-1/2 4 (2) 2-1/2 4 (2) 2-1/2 5 (2) 2-1/2 5 (3) 2-1/2 6 (4) 2-1/2 6 (6) 2-1/2 8 (6) 2-1/2 8 (6) 2-1/2 8 (8) 2-1/2 8 (12) 2-1/2 10 (12) 2-1/2 10 (16) 2-1/2 All rights reserved by SPP Pumps Ltd Hose Header Supply In. 1 1-1/2 2-1/2 2-1/2 2-1/2 3 3 4 4 4 6 6 8 8 8 10 10 12 12 Fire Pump System Components Electric Fire Pumps • • • • • • Pump, base, coupling & guard Electric motor Controller - motor Suction and discharge gauges Automatic air release valve Casing relief valve All rights reserved by SPP Pumps Ltd Fire Pump System Components Diesel Fire Pumps • • • • • • • • Pump, base, coupling & guard Diesel engine & fuel tank Controller - engine Suction and discharge gauges Automatic air release valve Batteries, racks & cables Cooling loop Commercial grade muffler, flexible exhaust connector & fittings All rights reserved by SPP Pumps Ltd Accessories for Fire Pump ClaVal 55L Casing relief Valve ClaVal 2050B-4KG Main Relief Valve ClaVal 90G-21 Pressure Reducing Valve All rights reserved by SPP Pumps Ltd Additional Accessories for fire pump Suction side eccentric reducer Discharge side concentric increaser Test Header Hose valves caps and chains All rights reserved by SPP Pumps Ltd Residential 13D The Resistream comes in 2 styles both the open unit with corrosion resistant base for mounting as well as the fully enclosed unit for simple and complete installation. Both units are available in either 115 or 220 volt single phase power depending on horsepower All rights reserved by SPP Pumps Ltd All rights reserved by SPP Pumps Ltd Suction Piping All rights reserved by SPP Pumps Ltd Pump Rotation All rights reserved by SPP Pumps Ltd How well do you know Fire Pumps? Fill in the blanks The first thing to ask when looking for a fire pump quote is the required ________________ and __________________ What are the 4 main types of fire pumps? – – – – Horizontal ___________ __________ Vertical _______ ___________ Turbine End ___________ Is the pump set driven by ____________ motor or _________________ Engine Do you need a __________ __________ (hint adds $13,000) What is the site _____________? (hint 208/230/460) All rights reserved by SPP Pumps Ltd I need a 1000 gpm at 90 psi fire pump, what size jockey do I need? What are the 3 points on a NFPA 20 pump curve? – ______________ (no flow) – _______________ % – _______________ % You have a 500 gpm fire pump, what is the flow at 100%? – ______________________ All rights reserved by SPP Pumps Ltd