Installation/Operating Instructions Targa Electric Projection Screen by Draper Operation Caution ➀ Read instructions through completely before proceeding. ➁ Follow instructions carefully. Installation contrary to instructions invalidates warranty. ➂ Screen should be accessible for complete removal should fabric become damaged or should other service be required. ➃ Screen should be installed level (using a carpenter’s level). ➄ Nothing should be fastened to screen dowel or viewing surface. ➅ Operating switch(es) packed separately in screen carton. Do not discard with packing material. ➆ Screen operates on 110-120V, 60 hz. current. NOTE: Screen has been thoroughly inspected and tested at factory and found to be operating properly prior to shipment. These instructions are meant as a guide only. They do not imply any responsibility on the part of Draper, Inc. for improper installation or faulty workmanship at the jobsite. Hanging Screen General: When locating viewing surface and checking clearance for screen’s operation, remember surface is centered in case. Handle case carefully to protect its finish. Regardless of mounting method, screen should be positively and securely supported so that vibration or even abusive pulling on the viewing surface will not cause case to work loose or fall. Installer must insure that fasteners used are of adequate strength and suitable for the mounting surface chosen. Suspended Installation: Suspend screens from holes in endcaps as shown. “S” hooks, chains (or cable) and turnbuckles should be provided by installer. “S” hooks should go through the front holes on the endcaps (see drawing on page 2), and both ends of the “S” hooks should be crimped for additional safety. Chains should be attached to beams or other structural members. Turnbuckles should be adjusted so screen hangs level. Wall Installation: Mount screen through holes in back of endcaps as shown. Installer should furnish screws, toggle bolts, molly bolts, nylon or lead anchors as required. Wall Installation with 6" Extension Brackets: Mount the brackets (not included with screen—see diagram below right) using hardware recommended for “Wall Installation” (above). Then, suspend the screen from the front holes with “S” hooks (as in “Suspended”). For added safety, crimp both ends of the “S” hooks so the screen cannot come off. For a more rigid installation, mount the screen from the back holes to the front of the bracket by using the screws and nuts provided with the brackets. Recessed Installation: Recess should permit access for removal of screen if necessary. Screen may be mounted as in suspended or wall installation. Optional Ceiling Opening Trim Kit available; see diagrams below and on page 2, and separate instruction sheet (included with Ceiling Opening Trim Kit). Electrical Connections Screen operates on 110-120v, 60 hz. current. Junction box is located inside left endcap and cover plate is secured to endcap with two screws. Junction box contains red, black and white pigtail leads and green internal ground wire, per wiring diagram on reverse. Screen is shipped with internal wiring complete and control switch(es) fully boxed. Wire connecting screen to switch(es) and switch(es) to power supply should be furnished by installer. Connections should be made in accordance with attached wiring diagram, and wiring should comply with National and local electrical codes. All operating switches should be “off” before power is connected. Screen Case Back Ceiling Tile (By others) Before operating screen remove tape securing fabric and dowel to roller. If viewing surface hangs out of case 8"-9", tape has probably been broken by rough handling in shipment, allowing surface to “unwrap” one turn about the roller. Manually wrap fabric back around the roller without turning the roller itself. 110-120V Single Station Control — 3-position up-off-down switch permits operation to be stopped at any point. Factory adjusted limit switches automatically stop screen when fully down or fully up. 110-120V Multiple Station Control—Switches are similar in appearance to 110-120V Single Station Control. Screen stops when switch is released and may be restarted in either direction. Factory adjusted limit switches stop screen automatically when fully up or fully down. 24V Control — Three-button up-stop-down switches stop at any point desired, operate in any sequence. Factory adjusted limit switches automatically stop screen when fully up or fully down. Key Operated Switching — Two kinds of key-operated switches are optionally available with this unit. ➀ The key-operated power supply switch controls power to the screen and switches. When it is “off ”, the switches will not operate screen. Key may be removed from the switch in either “on” or “off” position. ➁ A three-position key switch permits the screen to be operated directly by key. In this case, the screen’s operator must always have a key. RS232/Ethernet—Serial communication and network communication optionally available with wall switches, RF or IR remote. Limit Adjustments—Standard and Quiet Motor Screen has been factory set and should not normally require further adjustment. However, if you desire to change the “up” and “down” stopping positions, proceed as follows: CAUTION: Be sure all switches are in “off ” position before adjusting limit switches. Always be prepared to shut screen off manually when new adjust-ment is being tested. Screen may be severely damaged if viewing surface is allowed to run too far up or too far down. Adjusting “fully up” position — “Up” stopping position may be adjusted by turning the yellow limit switch adjustment socket. The yellow socket is located on left end of screen roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turning the socket counterclockwise will allow the viewing surface to retract farther into the case. Turning it clockwise will cause the surface to stop farther out of the case. One full revolution of the socket will alter the stopping position of the viewing surface by approximately 1½". Adjusting “fully down” position — “Down” stopping position may be adjusted by turning the white limit switch adjustment socket. The white socket is located on the left end of screen roller and is accessible to a screwdriver/Allen wrench (4mm or 5/32"). Turning the socket counterclockwise will allow the viewing surface to run farther down. Turning it clockwise will shorten the viewing surface, causing it to stop in a less extended position. At no time should viewing surface be unrolled enough to expose any part of screen roller. Limit Adjustments (Built-in Low Voltage Motors) ➀ Connect the ILT switch to the motor using four conductor modular cable. The cable connectors MUST NOT be crimped in reverse, as with standard telephone cable. ➁ Set the dip switch with 1 ON and 2 OFF. Press and hold the DOWN arrow on the switch to move the viewing surface to the desired lower limit. If the treatment moves in the opposite direction, release the DOWN button and depress the STOP button. This will reverse the operation of the UP and DOWN switches. ➂ Move the motor to the desired lower limit and return both dip switches to OFF to record position. ➃ Set the dip switch with 1 OFF and 2 ON. Move the viewing surface to the desired upper limit by pressing and holding the UP arrow on the wall switch. Return both dip switches to OFF to record position and return to normal operation. ➄ To set the viewing surface to an alternate format position, move the viewing surface to the desired position and press the STOP button. Press and hold the STOP button for at least three seconds to record the position. Please Note: Pressing and releasing the UP arrow on the switch will move the viewing surface to its upper limit. PressG + U D r 5V p o w o ing and releasing the DOWN arrow will move the viewing n u n surface to its lower limit. While the motor is in motion, pressing d the STOP button for less than P PO OTTSS FUNCTION two seconds will stop the viewing SW1 SW2 ON OFF Set LOWER limit surface at its present position. Once the motor is stopped, Set UPPER limit ON OFF To pressing the STOP button will Record Position/ Motor OFF OFF Normal Operation move the viewing surface to its Back View alternate format position. Pressing and holding the STOP button, when the motor is at rest or in motion, for at least three seconds will record a new alternate format position. 1 2 OFF 6" 6" Extension Bracket Copyright © 2007 Draper Inc. Form Targa_Inst07 Printed in U.S.A. If you encounter any difficulties installing or servicing your Targa screen, call your dealer or Draper Inc., Spiceland, Indiana, (765) 987-7999 or fax (765) 987-7142. Page 2 of 2 Targa by Draper Case Dimensions Types of Installation Wall Mounted 5 1/4" Fabric width + 7" 2 5/16" Suspended Appropriate hardware provided by installer. 5 7/8" Appropriate hardware provided by installer. Methods of Installation Fasteners for wall mounting by others. 7/8" dia. electrical connection hole Viewing surface 31/2" Wiring Diagrams—110-120V Motor and Quiet Motor Multiple Station Control Single Station Control Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) S Hooks for suspended installation by others. Internal Screen Wiring White (Common) Black (Down) Red (Up) Green (Ground) 7/8" hole for electrical connection. Cap off with wire nut and tape Dashed wiring by electrician Blue Control switch Red Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep Red Blue Black Red Optional Ceiling Opening Trim Kit (Dims-Side View) Dashed wiring by electrician Black Blue Location of key operated on-off switch if furnished Black Blue Red To 110-120V Line Black Single gang box by others Min. 4" x 2 1/8" x 1 7/8" deep. 3 shown. More or less equally feasible. Location of key operated on-off switch if furnished To 110-120V Line Wiring Diagrams—110-120V Motor and Quiet Motor with Built-in Low Voltage Controller 8" Single Low Voltage Control Multiple Low Voltage Controls Internal Screen Wiring White (Neutral) Black Green (Ground) 21/16" 11/16" 21/8" 4" 63/4" Dashed wiring by electrician Data Cable Internal Screen Wiring White (Neutral) Black Green (Ground) Dashed wiring by electrician Data Cables Wall Switch, RF or IR Receiver, or integrated control system To 110-120V Line www.draperinc.com (765) 987-7999 To 110-120V Line Wall Switches, RF or IR Receivers, or integrated control systems