M03E-EN-02B+S8VT+Datasheet.fm Seite 1 Montag, 8. Juni 2009 3:35 15 Switch Mode Power Supply S8VT 120/240/480/960 W Models Natural Cooling Three-phase Power Supply Range from 5A up to 40A with Output Voltage of 24VDC • 3 phase 400 to 500 VAC • 5, 10, 20 and 40 A; 24 VDC output • Higher stability, lower ripple and noise level • Mounts to DIN rail • Fuses protection included • Natural ventilation • UL60950 (CSA22.2-60950), UL508 listing in addition to the CE mark • Conform to EN61000-3-2 • Parallel & serial operation possible Model Number Structure Model Number Legend S8VT - 24 E 1 2 3 1. Input Voltage 2. Power Rating 3. Output Voltage F: 400 to 500 VAC 3-phase 120: 240: 480: 960: 24: 24 V 120 W 240 W 480 W 960 W Ordering Information List of Models Input voltage 400 to 500 VAC 3-phase Power rating Output voltage Output current Model number 120 W 24 V 5A S8VT-F12024E 240 W 24 V 10 A S8VT-F24024E 480 W 24 V 20 A S8VT-F48024E 960 W 24 V 40 A S8VT-F96024E 1 M03E-EN-02B+S8VT+Datasheet.fm Seite 2 Montag, 8. Juni 2009 3:35 15 S8VT Specifications Item Nominal Input Voltage Efficiency (400 VAC FULL LOAD) Input Output Others F: 400 to 500 VAC Nominal Input Current 5A 86% 10 A 90% 20 A 40 A 91% 91% Voltage range 340 to 576 V 3AC resp. 480 to 810 VDC Frequency 50 to 60 Hz Current (max.) (Vin = Range min., Pmax) 0.5A 1A 1.5A 3A Power factor (400 VAC FULL LOAD) 0.66 0.66 0.86 0.86 Leakage current (max.) <3.5mA <3.5mA <3.5mA <3.5mA Inrush current (max.) (Pmax) < 30A @ Vin max. < 30A @ Vin max. < 40A @ Vin max. < 30A @ Vin max. EMI filter 2×10 mH 2×27 mH 2×6.8 mH 2×2.2 mH Line fuses T2A T3.15A T4A T6.3A Voltage adjustment range 21.6 to 28.0 VDC min. Tolerance adjustment accuracy 1% Ripple & noise (Pmax.) 100 mV max. (p.p. 0-20 MHz) Load variation influence ±0.5% max. Input variation influence ±0.25% max. Temperature variation influence Less than 0.05%/°C Startup time (max.) 1.3 s 1.3 s 1.3 s 1.3 s Hold time (min.) (Vin = 400 VAC) 15 ms 15 ms 15 ms 15 ms Protection - Short circuit protection continuative - Over load protection - Over voltage protection Parallel operation Yes (for two units) Serial operation Yes (for two units) Indicator Yes (Green LED) Heat radiation Natural air cooling Ambient temperature -10 to 70°C (de-rating: 5%/°C for 60 to 70°C) Temperature power derating 60 to 70°C see diagram Storage temperature -40 to 85°C Ambient humidity 10 to 90% noncondensing Dielectric strength 2.5 kVAC Input-PE (for 1 sec.; routine test) 3 kVAC Input-Output on isolation components (transformers) (for 1 sec.; high-pot routine test) 1 kVAC Output-PE (for 1 sec.; routine test). Insulation resistance 500 Mohm min at 500 VDC, Output - P.E. Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y and Z directions 10 to 150 Hz, 0.35 mm single amplitude for 80 min each in-X, Y and Z directions Shock resistance 150 m/s², 3 times each in ±X, ±Y, ±Z directions EMC EN55011 (EN55022) EN61000-3-2, EN61000-4-2, EN61000-4-3,EN61000-4-4,EN61000-4-5, EN61000-4-6,EN61000-4-8,EN61000-4-11, EN61204-3 Approval standards (AC and DC input) IEC60950-1, EN60950-1 UL60950-1, CSA 22.2 No. 60950-1, UL508 Listed *1, EN50178, EN60204 Life expectancy 10 years (Vin=400-500 VAC 50% of rated output current Ta=40°C) MTBF *2 > 300.000hrs Weight 0.71 kg 0.91 kg 1.8 kg 3.3 kg *1) UL approval up to 600 VDC *2) MTBF stands for Mean Time Between Failures, which is calculated according to the probability of accidental device failures, and indicates reliability of devices. 2 M03E-EN-02B+S8VT+Datasheet.fm Seite 3 Montag, 8. Juni 2009 3:35 15 S8VT Operation Block Diagram S8VT-F AC-PH3 Vout- Driver P.E./Chassis Control Module Opto-isolator AC-PH2 RFI filter AC-PH1 Input Line Fuses Vout+ Ouput Voltage Control Module Engineering Data Definition of Inrush Current, Start up Time and Hold Time Input ON Input OFF AC input voltage Inrush current input application AC input current 90% 95% Output voltage Start up time Hold up time Overload Protection Overvoltage Protection The Power supply is provided with an overload protection function that protect the load and the power supply from possible damage by over current. When the output current rises above between 105 to 130% (105 to 120% for the 40 A model) of the rated current, the protection function is triggered, decreasing the output voltage. When output current falls within the rated range, the overload protection function is automatically cleared. 5 A and 10 A models De-rating Curve If output voltage exceed the rated voltage more than 25% (50% at maximum) by some reason, then the output voltage will be turned OFF automatically for safety. To restart the S8VT, turn OFF the input voltage, wait few minutes, then apply the input power again. P If output voltage exceed the rated voltage more than 25% (50% at maximum) by some reason, then the output voltage will be automatic limited for safety. 20 A and 40 A models Pmax 50% 60 70 °C For UL and CSA the maximum temperature is 60°C (70°C for the 20 A model) 3 M03E-EN-02B+S8VT+Datasheet.fm Seite 4 Montag, 8. Juni 2009 3:35 15 S8VT Dimensions and Nomenclature Note: All dimensions shown are in millimeters. S8VT-F12024E 5 6 10 9 7 130 8 136 125 11 2 1 3 4 10 7 9.9 45 S8VT-F24024E 6 9 8 130 181 170 5 1 2 3 11 4 9.9 45 S8VT-F48024E 9 6 10 7 8 130 181 170 5 1 2 3 11 4 9.9 100 S8VT-F96024E 195 181 170 130 1 1. 2. 3. 4. 4 AC input L1 AC input L2 AC input L3 P.E. (Protective Earth) 5. 6. 7. 8. 2 LED Vout ok Vadj. Trim Vout + Vout + 3 4 5 6 7 8 9 10 11 9.9 9. Vout 10.Vout 11.DIN-rail clip M03E-EN-02B+S8VT+Datasheet.fm Seite 5 Montag, 8. Juni 2009 3:35 15 S8VT Notice Three phase input operation when one phase is missing Serial Operation The S8VT will in most cases continue to operate even after the loss of one phase of the supply. The performance specifications are of course not guaranteed under these conditions. As the loss of one phase puts additional stress on some components, the life span of the unit could be shortened. It is prudent therefore to regularly check for signs of the following possible conditions. As shown below, the output voltage from each S8VT can be added. Types must be the same. +V −V Load 1. Input terminals wiring open/loose. 2. Incorrect/No voltage on one or more phases of the supply. 3. Abrupt or periodical loss of input voltage. +V The power supply needs output derating as in the chart for the operation on missing phase at the input voltage range of 340 to 576 V. Otherwise, the power supply may deteriorate or be damaged. In every single application suitability has to be checked. Missing phase de-rating 110 100 −V Parallel Operation As shown below, two S8VT-F (same capacity model) can be paralleled to boost the output power (current). Set the output voltages of the Power Supplies to the same value. Also, make sure that the thickness and the length of all wires connected to the load are the same to ensure that the wires will have no voltage drop difference. 90 80 70 Parallel connection is only permissible with ambient temperature from -10°C to +50°C. Load 60 (%) 50 In case of a redundant system or back-up system, use diode to be connected to output + terminal of all the Power Supplies. 40 +V 20 10 Load 30 −V 0 -20 -10 0 10 20 30 40 50 60 70 80 Ta (°C) S8VT-F12024E S8VT-F24024E S8VT-F48024E S8VT-F96024E Note: In two phase operation, the specification for EMC performance, hold-up time, efficiency and output ripple will no longer be valid. +V −V Three phase input switch off In order to switch off the Power Supply completely: All 3 phases need to be switched off. Mounting To improve and maintain the reliability of the Power Supply over a long period, adequate consideration must be taken to heat radiation. The S8VT is designed to radiate heat by natural air cooling, therefore, mount the S8VT so that enough air flow takes place around the power supply. If installing S8VTF closely, keep the minimum distance of 20 mm at 60°C ambient. Generating (±) Output Voltage An output of ± can be generated as shown below, since the S8VT has a floating output. −V Load +V Load +V −V 5 M03E-EN-02B+S8VT+Datasheet.fm Seite 6 Montag, 8. Juni 2009 3:35 15 S8VT Safety Precautions Safety Signal words This document uses the following signal words to mark safety precautions for the S8VT. These precautions provide important information for the safe application of the product. You must be sure to follow the instructions provided with safety signal words. !WARNING Indicates information that, if ignored, could possibly result in loss of life or seriously injury. !Caution Indicates information that, if ignored, could result in relatively serious or minor injury, damage to the product, or faulty operation. !WARNING Be sure to connect the grounding line. Not doing so may result in electric shock. !Caution Do not attempt to disassemble the Power Supply or touch its internal parts while power is being supplied. Doing so may result in electric shock. !Caution Do not touch the S8VT while the power is being supplied or immediately after the power is turned OFF. The case of the Power Supply can be still hot. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. M03E-EN-01 6 In the interest of product improvement, specifications are subject to change without notice.