PRODUCT LEAFLET DRY TYPE TRANSFORMER Single-phase, three-single, three-two and three-phase transformers 1.1 kV to 7.2 kV classes 1 60 40152 - 13/09/2011 Dry Type Transformers Transformers meant to be installed in a dry and air conditioned room or in a PTI AUGIER type substation. ELECTRICAL CHARACTERISTICS : Power rating and type : Single-phase : TMAI : 5 - 7.5 - 10 - 16 - 25 - 32 - 50 kVA Three-single : TTMAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-two : TTBAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 kVA Three-phase : TTAI : 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Standard : Three-phase transformer : Step-down Dyn11 - Step-up YNd1– single-phase transformer :Ii0 Specific : Three-single transformer, Leblanc three-two transformer, other couplings on request. Manufacturing specifications on request : Inrush current transformer reduced or very reduced. CONNEXION: Primary and secondary connesion on copper slots, by the upper side of the transformer. STANDARD ACCESSORIES : Empty setting plugs : Three outputs on slots. Two earthing switches. Lifting lugs. Four rollers for 10 kVA and higher power rating transformers. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. Single-phase transformer, TMAI type, with IP21 encolsure, fuse terminal 3200 V and locking. 2 CONSTRUCTION : Magnetical circuits with crystal made sheet metal, oriented, with low losses. Copper or aluminium windings, impregnated vacuum with a fungicide varnish, class H impregnation. Metallic flanges. Ironed chassis with rollers. Wooden terminals plate bakelised. Cooling Use Color : in natural air : NA. : use in dry, air conditioned rooms, at a room temperature of -15 °C ; + 40°C. : RAL 7035 gray. STANDARDS AND TESTS : Conforms to NFC 17200 - NFC 52100 - CEI 76 standards. Other specifications on request. Routine tests U.T.E made on each transformer, specific tests on request.. Dry type transformer, naked presentation on frame Connexion plates Tap changer MV side view LV side dismantle panel Fixation by screw Lifting lugs Connexion plates Dry type transformer With IP21 enclosure rollers Side panel dismantling (cables passage) Fixation by screw Bakélite matter To be screwed on request Signaletic plate Firm plate LV side dismantling panel 3 Three-phase dry Type Transformers TTAI ELECTRICAL CHARACTERISTICS : Power rating: 16 - 25 - 32 - 50 - 63 - 80 - 100 - 125 - 160 - 200 - 250 - 400 - 500 - 630 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V - 5500 V and 6600 V. Secondary load voltage : 400 V - 950 V - 3200 V - 5500 V and 6600 V. Couplings : Step-down Dyn11 - Step-up YNd1, other couplings on request. CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % or +- 5% output on slots. Two earthing terminals. Lifting lugs. Four rollers for 10 kVA and higher power rating transformers. Naked presentation on frame : IP00. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP 21. Connexion on pluggable terminals 3200 V or 5500 V. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kVA) 16 25 32 50 63 80 Copper losses at 75°C (W) 350 470 550 800 1000 1100 Iron losses (W) 100 180 200 250 250 Voltage drop (% ) at Cos = 0.83 3.3 3 3.07 3.14 CC tension (%) at 75°C 3.4 3.2 3.4 Empty current (%) 1 0.7 0.8 100 125 160 200 250 400 500 630 1350 1400 2000 2300 2800 4200 5600 7300 380 450 450 500 550 650 900 1250 1500 3.4 3 3.2 3 3.4 3.2 3.15 3.5 3.5 3.5 3.5 4 3.5 4 4 4 4 4 4 4.5 5 0.9 0.7 0.8 0.9 0.6 0.7 0.5 0.5 0.8 0.6 0.7 4 TTAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME - STEP DOWN TRANSFORMER Power rating (kVA) 16 25 32 50 63 80 100 125 160 200 250 400 500 630 A 636 750 825 825 840 930 930 950 980 1000 1096 1240 1400 1600 B 400 480 500 500 520 530 530 530 530 570 660 660 830 900 C 611 670 718 718 734 809 809 836 858 889 1086 1134 1300 1650 D 380 510 510 510 520 580 580 590 610 650 690 770 870 900 E 295 400 400 400 400 440 440 440 440 465 520 520 520 520 Weight (kg) 155 270 310 345 365 450 465 525 600 700 940 1185 1450 1800 Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE - STEP DOWN TRANSFORMER Power rating (kVA) 16 25 32 50 63 80 100 125 160 200 250 400 500 630 A 850 960 1040 1040 1050 1140 1140 1160 1190 1220 1310 1550 1610 1810 B 550 630 650 650 660 660 660 660 680 720 810 810 980 1050 C 900 970 1020 1030 1040 1100 1100 1140 1200 1200 1390 1500 1600 1950 D 380 510 510 510 520 580 580 590 610 650 690 770 870 900 E 295 400 400 400 400 440 440 440 440 465 520 520 520 520 Weight (kg) 185 300 350 400 405 535 565 630 750 900 1150 1450 1700 2050 Protection degree IP21 5 Single-phase Dry Type Transformers TMAI ELECTRICAL CHARACTERISTICS : Power rating: 5 - 7,5 - 10 - 16 - 25 - 32 - 50 kVA Insulation voltage : 1.1 kV - 3.6 kV - 7.2 kV Primary voltage : Every voltage compatible with insulation voltages above. Usually standard voltages are : 230 V - 400 V - 950 V - 3200 V. Secondary load voltage : 230 V - 950 V - 3200 V. Couplings : Standard : single-phase transformer : Ii0 CONNEXION : Primary and secondary connexions on copper plates, by the upper side of the transformer. STANDARD ACCESSORIES : Voltage tapping adjustable out of voltage : +/- 2,5 % ou +- 5% sorties sur plages. Two earthing terminals. Lifting lugs. Four rollers for 10 kVA and higher power rating transformers. Naked presentation on IP00 frame. OPTIONAL ACCESSORIES Painted sheet metal enclosure with natural airing upwards, IP 21. Connexion on pluggable terminals. HRC fuses protection integrated above the protection envelop. Thermal protection by thermal probe integrated to windings, one or two thresholds protection. Tap changers +/- 2,5 % +/- 5%. Keyhole locking of the protection envelop and or pluggable terminals. NOTE : Transformers mechanical and electrical characteristics are the same for step-down or step-up transformers. The tranformers are not reversible. Step-up transfrormers are built so that inrush currents are limited. ELECTRICAL CHARACTERISTICS Power rating (kVA) 5 7,5 10 16 25 32 50 Copper losses at 75°C (W) 100 120 170 380 500 630 750 Iron losses (W) 40 60 60 80 120 150 200 Voltage drop (% ) at Cos = 0.83 2.92 2.47 3.35 3.7 3.53 3.55 3.7 Cc tension (%) at 75°C 2.95 2.67 3.75 3.86 3.78 4 4 Empty current (%) 3.11 2.53 2.58 2.67 2.52 2.54 2.51 6 TMAI Dry Transformers SIZES-WEIGHT (mm) - PRESENTATION ON IP00 FRAME Power rating (kVA) 5 7,5 10 16 25 32 50 A 320 400 400 540 600 630 650 B 320 390 390 400 400 450 460 C 372 560 494 632 652 710 749 D - - 320 300 315 270 270 E - - 218 230 245 270 270 Weight (kg) 45 72 84 140 190 230 265 Protection degree IP00 SIZES-WEIGHT (mm) - PRESENTATION WITH IP21 ENCLOSURE Power rating(kVA) 5 7,5 10 16 25 32 50 A 380 424 424 570 630 670 700 B 344 414 414 450 460 550 570 C 532 570 600 830 850 960 1020 D - - 320 300 315 270 270 E - - 218 230 245 270 270 Weight (kg) 56 83 98 160 220 270 310 Protection degree IP121 7 With constant improvements, the manufacturer may alter information without prior warning AUGIER IS CERTIFIE ISO 9001 SINCE 1995