SERIES E TYPE VALVES
BULLETIN
E-2010
AIR VALVES FOR INDUSTRY SINCE 1949
E Full Size Manifold Mounting —
Page 4
Electric Quick Exhaust —
Page 13
E5 Compact —
Page 6
EZ Bantam —
Page 10
E Full Size —
Page 2
www.versa-valves.com
email: sales@versa-valves.com
Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey, USA 07652 • 201/843-2400 FAX: 201/843-2931
Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands • 01131-55-3681900 FAX: 01131-55-361909
SERIES E
Versa exercises diligence to assure that information contained in this catalog is correct,
but does not accept responsibility for any errors
or omissions. Versa also reserves the right to
change or delete data or products at any time
without prior notification. To be sure the data you
require is correct, consult factory.
FULL SIZE
Side-Ported Types
Series E Full-Size Side-Ported valves are direct solenoid actuated and are individually mounted. 1/8 NPT or 1/4 NPT ports are
provided in the valve body.
TECHNICAL DATA
Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult
factory for clarification.
Seals: Ordinary Location Valves—NBR (Nitrile) is standard; other sealing materials are available for compatibility with various
oils, acidic fluids & gases, etc. See Options on page 14 or consult factory.
Hazardous Location Valves—FKM (fluorocarbon) per ASTM D1418/ISO-1629.
Construction: Stainless steel (302, 304 & 430F) wetted parts. Coil cover is zinc chromate coated steel.
Electrical: Class F epoxy molded coils rated for continuous duty; 9.5-12 watt DC, 7.3-10 watt AC nominal power. See page 17
for coil voltages.
Ordinary Location Solenoids are CSA certified; NEMA 1, 2 & 3; NEMA 4/IP65.
Hazardous Location Solenoids are UL listed and CSA certified; NEMA 7 & 9. Solenoids approved by ATEX are also
available. See pages 16 & 18.
Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges.
Flow: See page 19.
Options: See pages 14 thru 16.
ORDINARY LOCATIONS
(NEMA 1, 2, 3)
PORTED ADAPTER-SPECIFY
-H FOR 1/4ⴖ NPT
-H2 FOR 1/8ⴖ NPT
24ⴖ (61 cm) COIL LEADS
#18AWG WIRE
C
HAZARDOUS LOCATIONS
(NEMA 7 & 9)
PORTED ADAPTER-SPECIFY
-H FOR 1/4ⴖ NPT
-H2 FOR 1/8ⴖ NPT
.75
19
1/2ⴖ NPT.
CONDUIT CONNECTION
C
.75
19
24ⴖ (61 cm) GROUND
LEAD
(GREEN)
24ⴖ (61 cm) COIL LEADS
#18AWG WIRE
1/2ⴖ NPT.
CONDUIT CONNECTION
2.82
71.6
OPTIONAL
MANUAL OVERRIDE
OPTIONAL
MANUAL OVERRIDE
3.22
81.8
1.84
46.7
.62
15.7
B
.31
7.9
1.88 ø
47.8
2.16
54.9
.34
8.6
1.62 ø
41
.62
15.7
B
.31
7.9
1/8 OR 1/4ⴖ NPT.
( 2 PORTS)
1.62 ø
41
.34
8.6
1/8 OR 1/4ⴖ NPT.
( 2 PORTS)
DIMENSIONS SHOWN IN INCH
MM
2.39
60.7
B
2.59
65.8
B
.88
22.4
.44
11.2
A
.44
11.2
.88
22.4
A
#10 - 32 UNF - 2B
x .31 THREAD DEPTH
( 2 MOUNTING HOLES )
#10 - 32 UNF - 2B
x .31 THREAD DEPTH
( 2 MOUNTING HOLES )
.44
11.2
.88
22.4
.44
.88 11.2
22.4
Color shows piped port C or normally open valve; metric dimensions.
Coil cover shown is supplied as standard and provides housing with threaded boss for conduit connection. Other housing types
are available. See Suffix Detail Options on page 14.
2
ORDINARY LOCATIONS
(For Coil Voltages See Page 17)
Type
TWO-WAY 2/2
NORMALLY CLOSED
Air, Oil or Water
Maximum
Operating
Pressure
Differential1
psi (bar)2
250 (17)
200 (14)
125 (8.6)
100 (6.9)
75-50 (5.2-3.4)
50-25 (3.4-1.7)
20-5 (1.4-0.3)
Product Number
with conduit type coil housing. For other
housing options see page 14.
1/8” NPT
ESM-2201-30-(*)
ESM-2201-40-(*)
ESM-2201-60-(*)
ESM-2201-80-(*)
ESM-2201-100-(*)
ESM-2201-120-(*)
ESM-2201-160-(*)
1/4” NPT
ESM-2301-30-(*)
ESM-2301-40-(*)
ESM-2301-60-(*)
ESM-2301-80-(*)
ESM-2301-100-(*)
ESM-2301-120-(*)
ESM-2301-160-(*)
Min. Orifice
between Ports
“A”-“B”
Piping Arrangement
and Flow Pattern
“B”-“C”
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
5/32 (4.0 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
B
DE-ENERGIZED
ENERGIZED
A
Port B = Inlet
Port A = Outlet
A
B
Port B blocked to Port A.
TWO-WAY 2/2
NORMALLY OPEN
Air, Oil or Water
200 (14)
150 (10)
125 (8.6)
ESM-2202-03-H2-(*)
ESM-2202-04-H2-(*)
ESM-2202-06-H2-(*)
ESM-2302-03-H-(*)
ESM-2302-04-H-(*)
ESM-2302-06-H-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
B
DE-ENERGIZED
ENERGIZED
C
C
C
Port B = Inlet
Port C = Outlet
B
Port B connected to Port C.
THREE-WAY 3/2
NORMALLY CLOSED
(EXHAUST TO
ATMOSPHERE)
Air Only
150 (10)
100 (6.9)
75 (5.2)
50 (3.4)
20 (1.4)
Vac-AC only
ESM-3201-34-(*)
ESM-3201-44-(*)
ESM-3201-66-(*)
ESM-3201-86-(*)
ESM-3201-126-(*)
ESM-3201-166-(*)
ESM-3301-34-(*)
ESM-3301-44-(*)
ESM-3301-66-(*)
ESM-3301-86-(*)
ESM-3301-126-(*)
ESM-3301-166-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
THREE-WAY 3/2
NORMALLY CLOSED
(PIPED EXHAUST)
Air, Oil or Water
150 (10)
100 (6.9)
75 (5.2)
50 (3.4)
20 (1.4)
Vacuum-AC
only
ESM-3201-34-H2-(*)
ESM-3201-44-H2-(*)
ESM-3201-66-H2-(*)
ESM-3201-86-H2-(*)
ESM-3201-126-H2-(*)
ESM-3201-166-H2-(*)
ESM-3301-34-H-(*)
ESM-3301-44-H-(*)
ESM-3301-66-H-(*)
ESM-3301-86-H-(*)
ESM-3301-126-H-(*)
ESM-3301-166-H-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
ESM-3202-43-H2-(*)
ESM-3202-44-H2-(*)
ESM-3202-84-H2-(*)
ESM-3202-66-H2-(*)
ESM-3202-86-H2-(*)
ESM-3302-43-H-(*)
ESM-3302-44-H-(*)
ESM-3302-84-H-(*)
ESM-3302-66-H-(*)
ESM-3302-86-H-(*)
1/16” (1.6 mm)
1/16” (1.6 mm)
1/8” (3.2 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
THREE-WAY 3/2
NORMALLY OPEN
Air, Oil or Water
150 (10)
100 (6.9)
100 (6.9)
75 (5.2)
75 (5.2)
A C
ENERGIZED
C
ESM-7202-43-H2-(*)
ESM-7202-44-H2-(*)
ESM-7202-66-H2-(*)
ESM-7202-86-H2-(*)
ESM-7302-43-H-(*)
ESM-7302-44-H-(*)
ESM-7302-66-H-(*)
ESM-7302-86-H-(*)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
B
A
150 (10)
100 (6.9)
75 (5.2)
ESM-8202-33-H2-(*)
ESM-8202-44-H2-(*)
ESM-8202-66-H2-(*)
ESM-8302-33-H-(*)
ESM-8302-44-H-(*)
ESM-8302-66-H-(*)
A
B
Port A blocked to Port B;
Port B connected to Port C.
DE-ENERGIZED
Port A connected to Port B;
Port C blocked.
A C
ENERGIZED
C
C
B
Port C = Inlet
Port B = Cylinder Port
Port A = Exhaust
A
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
DE-ENERGIZED
A
B
Port C blocked.
Port B connected to Port A.
A C
ENERGIZED
C
C
B
A
Port B connected to Port C;
Port A blocked.
THREE-WAY 3/2
MULTI-PURPOSE
Air, Oil or Water
C
B
Port A = Inlet
Port B = Cylinder Port
Port C = Exhaust
B
200 (14)
150 (10)
125 (8.6)
100 (6.9)
B
Port B blocked to Port C.
DE-ENERGIZED
Port C connected to Port B;
Port A blocked.
THREE-WAY 3/2
DIRECTIONAL
CONTROL
Air, Oil or Water
A
B
Port B connected to Port A.
3/64” (1.2 mm) 3/64” (1.2 mm)
1/16” (1.6 mm) 1/16” (1.6 mm)
3/32” (2.4 mm) 3/32” (2.4 mm)
B
Port B = Inlet
Port C = Outlet I
Port A = Outlet II
A
B
Port B connected to Port A;
Port C blocked.
A C
B
DE-ENERGIZED
C
B
A
Multi-purpose valves may be
used as Three-Way, NC or ThreeWay, NO or Directional Control
Valves. Two-Way, NC or Two-Way,
NO can be accomplished by
plugging the appropriate port.
ENERGIZED
C
B
A
HAZARDOUS LOCATIONS
Add Suffix -XX To Above
Product Numbers
(See page 16 for other Hazardous
Location Solenoids)
NOTES:
*Specify coil code # from page 17.
1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure in color is for DC. Vacuum is AC only.
2. MPa = bar
10
3
SERIES E
FULL SIZE
Manifold-Mounting Types
Each Series E Full-Size Manifold Mounting valve is direct solenoid actuated and is mounted on a manifold which
can have 1 to 10 valve stations. The manifolds are provided with the threaded ports for pipe connections, which allows
the valves to be easily and swiftly installed or removed without breaking any pipe connections. The manifolds also
provide common ports, such as the inlet and exhaust, making only one such connection necessary per manifold.
Installation is neater and maintenance easier since valves are grouped in one location. Several different piping
arrangements are available to provide flexibility of application.
Valves are supplied assembled to manifolds, but must be ordered separately. Station Blanks (E-189) are available for
blocking off any unused or “future” valve stations on the manifold. To order complete unit, specify manifold desired
and quantity and valve model number required. Valves must all be the same model.
TECHNICAL DATA
Application: Air, oil or water, and many other media that are
compatible with the specific sealing materials used. Consult
factory for clarification.
Seals: NBR (nitrile) is standard; other sealing materials are
available for compatibility with various oils, acidic fluids & gases,
etc. See Options on page 14 or consult factory.
Construction: Valve bodies and manifolds are aluminum.
(Stainless steel valve bodies and manifolds are available. Consult
factory.) Wetted solenoid parts are stainless steel (302, 304 &
430F). Coil cover is zinc chromate coated steel.
Electrical: Class F epoxy molded coils rated for continuous duty;
9.5-12 watt DC, 7.3-10 watt AC nominal power. See page 17 for
coil voltages.
Ordinary Location Solenoids are CSA certified:
NEMA 1, 2 & 3; NEMA 4/IP65.
Hazardous Location Solenoids are UL listed and
CSA certified; NEMA 7 & 9.
Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory
for other temperature ranges.
Flow: See page 19.
Options: See pages 14 thru 16.
WITHOUT ELECTRICAL PLUG-IN
(NEMA 1, 2, 3)
WITH ELECTRICAL PLUG-IN
(NEMA 1, 2, 3)
Typical THREE-WAY Normally Closed Type
DIMENSIONS SHOWN IN INCH
MM
(Piped Exhaust)
FEATURES OF MANIFOLD:
COMMON INLET FOR ALL VALVES
INDIVIDUAL OUTLETS (CYLINDER PORTS) FOR EACH
VALVE
COMMON EXHAUST PORT FOR ALL VALVES
Plug-in type also has common electrical junction box & conduit
connection
(Types Available Include 2-Way
NC, 2-way NO, 3-way NC, 3-Way
NO, Directional. Consult factory
for information concerning
specific product required.)
(Exhaust to Atmosphere)
FEATURES OF MANIFOLD:
COMMON INLET FOR ALL VALVES
INDIVIDUAL OUTLETS (CYLINDER PORTS) FOR EACH
VALVE
Plug-in type also has common electrical junction box & conduit
connection
1/2⬙ Standard Conduit Connection
3/4 NPT Electrical
Conduit Connection
1.75
44.5
2.0
51
EXHAUST
(BOTH ENDS)
1.78
45.2
Typical
SEE TABLE FOR VALVE
PRODUCT NUMBER
6.56
167
Two Mounting Holes for 1/4⬙ Screws
1/4 NPT Cylinder Ports
1.25
31.8
4
CYL
CYL
CYL
4.5
114
2.0
51
SINGLE STATION:
1/4 NPT
MULTIPLE STATION:
3/8 NPT
INLET BOTH ENDS
Add 1.78” (45.2 mm) for each
additional valve station required.
Detail and descriptions in color
apply to plug-in type valve and
manifold.
1.78
45.2 Typical
6.56
167
Two Mounting Holes for 1/4⬙ Screws
1/4 NPT Cylinder Ports
1.25
31.8
CYL
CYL
CYL
ORDINARY LOCATIONS
(For Coil Voltages See Page 17)
Product Number
Valve
Type
TWO-WAY 2/2
NORMALLY CLOSED
Air, Oil or Water
TWO-WAY 2/2
NORMALLY OPEN
Air, Oil or Water
Maximum
Operating
Pressure
Differential (Note 1)
psi (bar) (Note 2)
250 (17)
200 (14)
125 (8.6)
100 (6.9)
75-50 (5.2-3.4)
50-25 (3.4-1.7)
20-5 (1.4-0.3)
200 (14)
150 (10)
125 (8.6)
Listed with
conduit type
coil housing.
(Note 3)
Manifold
Min. Orifice
between Valve Ports
One Inlet
(3/8 NPT)
serves all Valves:
Individual Outlets
(1/4 NPT)
(Notes 3 & 4)
Individual Inlet
(1/4 NPT) and
Outlet (1/4 NPT)
for Each Valve
(Notes 3 & 4)
Individual Inlet
(1/4 NPT) for Each
Valve: One Outlet
(3/8 NPT) Serves
all (Notes 3 & 4)
ESM-2011-30-(*)
ESM-2011-40-(*)
ESM-2011-60-(*)
ESM-2011-80-(*)
ESM-2011-100-(*)
ESM-2011-120-(*)
ESM-2011-160-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
5/32” (4.0 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
EM-21-210-†
EM-21-220-†
EM-21-120-†
ESM-2012-03-Z-(*)
ESM-2012-04-Z-(*)
ESM-2012-06-Z-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
EM-22-012-†
EM-22-022-†
—
EM-31-210-†
“In”“Cyl”
“Cyl”
“Exh”
THREE-WAY 3/2
NORMALLY CLOSED
(EXHAUST TO
ATMOSPHERE)
Air Only
150 (10)
100 (6.9)
75 (5.2)
50 (3.4)
20 (1.4)
Vacuum-AC Only
ESM-3011-34-(*)
ESM-3011-44-(*)
ESM-3011-66-(*)
ESM-3011-86-(*)
ESM-3011-126-(*)
ESM-3011-166-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
EM-31-120-†
EM-31-220-†
THREE-WAY 3/2
NORMALLY CLOSED
(COMMON PIPED
EXHAUST)
Air, Oil or Water
150 (10)
100 (6.9)
75 (5.2)
50 (3.4)
20 (1.4)
Vacuum-AC Only
ESM-3011-34-Z-(*)
ESM-3011-44-Z-(*)
ESM-3011-66-Z-(*)
ESM-3011-86-Z-(*)
ESM-3011-126-Z-(*)
ESM-3011-166-Z-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
EM-31-121-†
EM-31-221-†
150 (10)
100 (6.9)
100 (6.9)
75 (5.2)
75 (5.2)
ESM-3012-43-Z-(*)
ESM-3012-44-Z-(*)
ESM-3012-84-Z-(*)
ESM-3012-66-Z-(*)
ESM-3012-86-Z-(*)
3/64” (1.2 mm) 1/16” (1.6 mm)
1/16” (1.6 mm) 1/16” (1.6 mm)
1/16” (1.6 mm) 1/8” (3.2 mm)
3/32” (2.4 mm) 3/32” (2.4 mm)
3/32” (2.4 mm) 1/8” (3.2 mm)
EM-32-121-†
THREE-WAY 3/2
NORMALLY OPEN
(COMMON PIPED
EXHAUST)
Air, Oil or Water
“In”“Out 1”
THREE-WAY 3/2
DIRECTIONAL
CONTROL
Air, Oil or Water
200 (14)
150 (10)
125 (8.6)
100 (6.9)
ESM-7012-43-Z-(*)
ESM-7012-44-Z-(*)
ESM-7012-66-Z-(*)
ESM-7012-86-Z-(*)
Add Suffix -XX
to Valve Product
Numbers Shown
Above. See
Pages 16 & 18
for Other Options
3/64” (1.2 mm) 1/16” (1.6 mm)
1/16” (1.6 mm) 1/16” (1.6 mm)
3/32” (2.4 mm) 3/32” (2.4 mm)
3/32” (2.4 mm) 1/8” (3.2 mm)
{
†Insert Number of Valve Stations
Required. Manifolds Are Supplied In
1 to 10 Stations.
“In”“Out 2”
HAZARDOUS
LOCATIONS
}
EM-72-212-†
Change Prefix “EM”
to “E7M.” Example:
E7M-72-212-†.
NOTES:
*Specify coil code # from page 17.
1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure in color is for DC. Vacuum is AC only.
2. MPa = bar
10
3. To specify electrical plug-in option add -P to product number shown. Indicator lights mounted in junction box can also be provided when
using plug-in valves. Use Suffix -36B for this option. Limitation: 90-250VDC, 70-250VAC/50 or 60 Hz. Plug in option not available with
solenoids for hazardous location.
4. All ports of single station manifolds are 1/4 NPT.
5
SERIES E5
COMPACT
Versa exercises diligence to assure that information contained in this catalog is correct,
but does not accept responsibility for any errors
or omissions. Versa also reserves the right to
change or delete data or products at any time
without prior notification. To be sure the data you
require is correct, consult factory.
Side-Ported Types
Series E5 compact valves are direct solenoid actuated valves. They are physically smaller than the
Series E full-size valves described on pages 2 through 5, but offer most of the same orifice sizes and
operating pressure ranges as the larger valves. Ports are 1/8 NPT in the valve body and the valves are
individually mounted.
TECHNICAL DATA
Application: Air, oil or water, and many other media that are compatible with the specific sealing
materials used. Consult factory for clarification.
Seals: Ordinary Location Valves—NBR (Nitrile) is standard; other sealing materials are available for
compatibility with various oils, acidic fluids & gases, etc. See Options on page 14 or consult
factory.
Hazardous Location Valves—FKM (fluorocarbon) per ASTM D1418/ISO-1629.
Construction: Stainles steel (302, 304 & 430F) wetted parts. Coil cover is zinc chromate coated steel
(available in 182FM stainless steel on Hazardous Location valves). See Options on page 14.
Electrical: Class F epoxy molded coils rated for continuous duty; 1.8-10.5 watt DC, 4-8.5 watt AC
nominal power. See page 17 for coil voltages.
Ordinary Location Solenoids are CSA certified; NEMA 1, 2 & 3; NEMA 4/IP65.
Hazardous Location Solenoids are UL listed and CSA certified; NEMA 7 & 9. Solenoids
approved by FM & ATEX are also available. See pages 16 & 18.
Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges.
Flow: See page 19.
Options: See pages 14 thru 18.
ORDINARY LOCATION
VALVE
(NEMA 1, 2, 3)
6
HAZARDOUS LOCATION
VALVE
(NEMA 7 & 9)
ORDINARY LOCATION VALVE
PIPED EXHAUST
1.3
34
1.3
34
1/2 NPT
CONDUIT
HOUSING
(NEMA 1, 2, 3)
1/2 NPT
3.0
75
2.4
61
1.5
38
1.5
38
0.3
7.5
1.0
25.4
0.3
7.5
0.3
7.5
1.0
25.4
0.2
5.2
0.2
5.2
0.3
7.5
0.3
7.5
0.3
7.5
0.2
5.2
GROMMETED
LEADS
(NEMA 1, 2, 3)
Mounting Holes
# 8-32 UNC x 15/64⬙ (5.9)
2 places as shown
0.2
5.2
Two-Way NC
Three-Way NC (Exhaust to Atmosphere)
Mounting Holes
# 8-32 UNC x 15/64⬙ (5.9) Thd.
2 places as shown
Three-Way NC (Piped Exhaust)
Three-Way NO
Two-Way NO
Directional
Multi-purpose
DIN COIL &
CONNECTOR
(NEMA 4/IP65)
DIMENSIONS SHOWN IN INCH
MM
HAZARDOUS LOCATION VALVE
(NEMA 7 & 9)
UL Listed or CSA Certified.
(See pages 16 & 18 for other Hazardous Location Solenoids)
All coils provided
with 3rd
wire ground
1.5
39
1.5
39
1/8 PTF
1/2 NPT
1/2 NPT
3.3
83
2.5
63
1.6
0.9 42
23
1/8 PTF
(2 PLACES)
0.2
0.3 5.2
7.5
1.0
25.4
0.3
7.5
0.9
23
1/8 PTF
(2 PLACES)
0.2
5.2
0.3
7.5
0.2
5.2
8-32 UNC 15/64⬙ DEEP
2 places (5.9)
DIMENSIONS SHOWN IN INCH
MM
Two-Way NC
Three-Way NC (Exhaust to Atmosphere)
0.3
7.5
1.4
37
1.4
37
0.3
7.5
1.0
25.4
1.6
42
0.3
7.5
0.2
5.2
8-32 UNC 15/64⬙ DEEP
2 places (5.9)
Three-Way NC (Piped Exhaust)
Three-Way NO
Two-Way NO
Directional
Multi-purpose
7
SERIES E5
COMPACT
ORDINARY LOCATIONS (For Coil Voltage See Page 17)
Maximum Operating Pressure
Differential — psi (bar)††
Type
AC
DC
with 1/2” NPT Conduit
Connection
with DIN Coil &
Connector
with Grommeted Leads
NC-Comm
E5SM-2201-20-(*)
E5SM-2201-30-(*)
E5SM-2201-40-(*)
E5SM-2201-60-(*)
E5SM-2201-80-(*)
E5SM-2201-20-HC-(*)
E5SM-2201-30-HC-(*)
E5SM-2201-40-HC-(*)
E5SM-2201-60-HC-(*)
E5SM-2201-80-HC-(*)
E5SM-2201-20-243-(*)
E5SM-2201-30-243-(*)
E5SM-2201-40-243-(*)
E5SM-2201-60-243-(*)
E5SM-2201-80-243-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
E5SM-2202-02-H2-(*)
E5SM-2202-03-H2-(*)
E5SM-2202-04-H2-(*)
E5SM-2202-02-HC-H2-(*)
E5SM-2202-03-HC-H2-(*)
E5SM-2202-04-HC-H2-(*)
E5SM-2202-02-H2-243-(*)
E5SM-2202-03-H2-243-(*)
E5SM-2202-04-H2-243-(*)
Comm-NO
TWO-WAY 2/2
NORMALLY
CLOSED
Air, Oil or Water
500
400
200
100
75
TWO-WAY 2/2
NORMALLY
OPEN
Air, Oil or Water
400 (27)
200 (14)
125 (8.6)
200 (14)
100 (6.9)
60 (4.1)
THREE-WAY 3/2
NORMALLY
CLOSED
(EXHAUST TO
ATMOSPHERE)
Air Only
200
150
150
100
60
30
(14)
(10)
(10)
(6.9)
(4.1)
(2.1)
200
150
150
100
60
30
(14)
(10)
(10)
(6.9)
(4.1)
(2.1)
E5SM-3201-22-(*)
E5SM-3201-33-(*)
E5SM-3201-34-(*)
E5SM-3201-44-(*)
E5SM-3201-64-(*)
E5SM-3201-84-(*)
E5SM-3201-22-HC-(*)
E5SM-3201-33-HC-(*)
E5SM-3201-34-HC-(*)
E5SM-3201-44-HC-(*)
E5SM-3201-64-HC-(*)
E5SM-3201-84-HC-(*)
E5SM-3201-22-243-(*)
E5SM-3201-33-243-(*)
E5SM-3201-34-243-(*)
E5SM-3201-44-243-(*)
E5SM-3201-64-243-(*)
E5SM-3201-84-243-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
THREE-WAY 3/2
NORMALLY
CLOSED
(PIPED
EXHAUST)
Air, Oil or Water
200
150
150
100
60
30
(14)
(10)
(10)
(6.9)
(4.1)
(2.1)
200
150
150
100
60
30
(14)
(10)
(10)
(6.9)
(4.1)
(2.1)
E5SM-3201-22-H2-(*)
E5SM-3201-33-H2-(*)
E5SM-3201-34-H2-(*)
E5SM-3201-44-H2-(*)
E5SM-3201-64-H2-(*)
E5SM-3201-84-H2-(*)
E5SM-3201-22-HC-H2-(*)
E5SM-3201-33-HC-H2-(*)
E5SM-3201-34-HC-H2-(*)
E5SM-3201-44-HC-H2-(*)
E5SM-3201-64-HC-H2-(*)
E5SM-3201-84-HC-H2-(*)
E5SM-3201-22-H2-243-(*)
E5SM-3201-33-H2-243-(*)
E5SM-3201-34-H2-243-(*)
E5SM-3201-44-H2-243-(*)
E5SM-3201-64-H2-243-(*)
E5SM-3201-84-H2-243-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
THREE-WAY 3/2
NORMALLY
OPEN
Air, Oil or Water
150
125
100
75
(10)
(8.6)
(6.9)
(5.2)
150
125
75
45
(10)
(8.6)
(5.2)
(3.1)
E5SM-3202-22-H2-(*)
E5SM-3202-33-H2-(*)
E5SM-3202-44-H2-(*)
E5SM-3202-64-H2-(*)
E5SM-3202-22-HC-H2-(*)
E5SM-3202-33-HC-H2-(*)
E5SM-3202-44-HC-H2-(*)
E5SM-3202-64-HC-H2-(*)
E5SM-3202-22-H2-243-(*)
E5SM-3202-33-H2-243-(*)
E5SM-3202-44-H2-243-(*)
E5SM-3202-64-H2-243-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
THREE-WAY 3/2
DIRECTIONAL
CONTROL
Air, Oil or Water
300
200
100
75
(21)
(14)
(6.9)
(5.2)
200
100
50
25
(14)
(6.9)
(3.4)
(1.7)
E5SM-7202-22-H2-(*)
E5SM-7202-33-H2-(*)
E5SM-7202-44-H2-(*)
E5SM-7202-64-H2-(*)
E5SM-7202-22-HC-H2-(*)
E5SM-7202-33-HC-H2-(*)
E5SM-7202-44-HC-H2-(*)
E5SM-7202-64-HC-H2-(*)
E5SM-7202-22-H2-243-(*)
E5SM-7202-33-H2-243-(*)
E5SM-7202-44-H2-243-(*)
E5SM-7202-64-H2-243-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
1/16” (1.6 mm)
THREE-WAY 3/2
MULTIPURPOSE
Air, Oil or Water
125 (8.6)
100 (6.9)
65 (4.5)
125 (8.6)
100 (6.9)
50 (3.4)
E5SM-8202-22-H2-(*)
E5SM-8202-33-H2-(*)
E5SM-8202-44-H2-(*)
E5SM-8202-22-HC-H2-(*)
E5SM-8202-33-HC-H2-(*)
E5SM-8202-44-HC-H2-(*)
E5SM-8202-22-H2-243-(*)
E5SM-8202-33-H2-243-(*)
E5SM-8202-44-H2-243-(*)
1/32” (0.8 mm) 1/32” (0.8 mm)
3/64” (1.2 mm) 3/64” (1.2 mm)
1/16” (1.6 mm) 1/16” (1.6 mm)
1/2 NPT Conduit
Connection
Mini-DIN
Connector
Grommeted Leads
(Flying Leads)
(34)
(27)
(14)
(6.9)
(5.2)
250
150
100
45
25
NOTES:
*Specify coil code # from page 17.
†
For air only.
††
MPa = bar
10
8
Minimum Orifice
between Ports
Product Number
(17)
(10)
(6.9)
(3.1)
(1.7)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
HAZARDOUS LOCATION VALVES
UL Listed or CSA Certified.
(See pages 16 & 18 for other Hazardous Location Solenoids)
Low Wattage
†For Air Only
Standard
Wattage
NO
COM
DE-ENERGIZED
NO
1.8 Watt Max
See Available Voltage Below
E5SM-2201-20-XX-(*)
E5SM-2201-30-XX-(*)
E5SM-2201-40-XX-(*)
E5SM-2201-60-XX-(*)
E5SM-2201-80-XX-(*)
120 (8.3)
80 (5.5)
50 (3.4)
E5SM-2201-20-LB-XX-(*)
E5SM-2201-30-LB-XX-(*)
E5SM-2201-40-LB-XX-(*)
E5SM-2202-02-H2-XX-(*)
E5SM-2202-03-H2-XX-(*)
E5SM-2202-04-H2-XX-(*)
120 (8.3)
50 (3.4)
E5SM-2202-03-H2-LB-XX-(*)
E5SM-2202-04-H2-LB-XX-(*)
E5SM-3201-22-XX-(*)
E5SM-3201-33-XX-(*)
E5SM-3201-34-XX-(*)
E5SM-3201-44-XX-(*)
E5SM-3201-64-XX-(*)
E5SM-3201-84-XX-(*)
120 (8.3)
60 (4.1)
30 (2.1)
E5SM-3201-23-LB-XX-(*)
E5SM-3201-33-LB-XX-(*)
E5SM-3201-44-LB-XX-(*)
E5SM-3201-22-H2-XX-(*)
E5SM-3201-33-H2-XX-(*)
E5SM-3201-34-H2-XX-(*)
E5SM-3201-44-H2-XX-(*)
E5SM-3201-64-H2-XX-(*)
E5SM-3201-84-H2-XX-(*)
120 (8.3)
60 (4.1)
30 (2.1)
E5SM-3201-23-H2-LB-XX-(*)
E5SM-3201-33-H2-LB-XX-(*)
E5SM-3201-44-H2-LB-XX-(*)
E5SM-3202-22-H2-XX-(*)
E5SM-3202-33-H2-XX-(*)
E5SM-3202-44-H2-XX-(*)
E5SM-3202-64-H2-XX-(*)
COM - INLET
NO - OUTLET
NC - OUTLET
E5SM-7202-22-H2-XX-(*)
E5SM-7202-33-H2-XX-(*)
E5SM-7202-44-H2-XX-(*)
E5SM-7202-64-H2-XX-(*)
NO
NC
COM NC
COM
DE-ENERGIZED
ENERGIZED
AC or DC
N0 - INLET
COM - OUTLET
NC - EXHAUST
NO
NC
COM NC
COM
DE-ENERGIZED
ENERGIZED
NO
NC - INLET
COM - OUTLET
NO - EXHAUST
NO
NC
COM NC
COM
DE-ENERGIZED
ENERGIZED
NO
COM - INLET
NC - OUTLET
NO
NC
COM NC
COM
DE-ENERGIZED
ENERGIZED
NO
COM - INLET
NC - OUTLET
NO
COM
ENERGIZED
Product Number†
(For Coils Available; See Below)
Product Number
(For Coils Available
See Page 17)
Piping Arrangement
and Flow Pattern
NC
COM NC
COM
DE-ENERGIZED
ENERGIZED
Maximum Operating
Pressure Differential†
psi (bar)††
FOR INLET/OUTLET
INFORMATION
SEE CHART BELOW
E5SM-8202-22-H2-XX-(*)
E5SM-8202-33-H2-XX-(*)
E5SM-8202-44-H2-XX-(*)
1/2 NPT Conduit
Connector
PORT
N.C.
N.O.
COM.
2-WAY
N.O.
PLUG
OUTLET
INLET
2-WAY
N.C.
OUTLET
PLUG
INLET
3-WAY
N.O.
EXHAUST
INLET
OUTLET
3-WAY
N.C.
INLET
EXHAUST
OUTLET
AC
Voltage
12/60
24/60
48/60
120/60
240/60
Coil Code #
A012
A024
A048
A120
A240
DC
Voltage
6
12
24
48
120
Coil Code #
D006
D012
D024
D048
D120
1/2 NPT Conduit
Connector
SELECTOR DIVERTER
INLET
INLET
OUTLET
OUTLET
OUTLET
INLET
9
SERIES EZ
Versa exercises diligence to assure that information contained in this catalog is correct,
but does not accept responsibility for any errors
or omissions. Versa also reserves the right to
change or delete data or products at any time
without prior notification. To be sure the data you
require is correct, consult factory.
BANTAM
Side Ported Types
Series EZ Bantam valves are direct solenoid actuated valves and, physically are the smallest of the Series E type valves. Ports
are 1/8 NPT in the valve body and are individually mounted. See below for technical data.
Multiple Manifold Types
Series EZ Bantam Multiple Manifold valves are direct solenoid actuated and have 2 to 10 valve cavities within a single body.
Each valve within the manifold must be the same and perform the same function. See page 12 for a typical product example.
Functional Types Available
2-way, NC or NO . . . . . . . .
3-way, NC . . . . . . . . . . . .
3-way, NO . . . . . . . . . . . .
Multipurpose . . . . . . . . . . .
.
.
.
.
.
.
.
.
.
.
.
.
Ports Provided
. Common inlet, individual outlets
. Common inlet, individual outlets, exhaust to atmosphere. Common exhaust is available.
. Common inlet & exhaust, individual outlets
. Individual “NC,” “COM,” & “NO” ports
TECHNICAL DATA FOR SIDE-PORTED AND MULTIPLE MANIFOLD TYPES
Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult
factory for clarification.
Seals: FKM (fluorocarbon) per ASTM D1418/ISO-1629.
Construction: Aluminum body or manifold; stainless steel (302, 304 & 430F) solenoid wetted parts.
Electrical: Class F epoxy molded coil rated for continuous duty; 10.5 watt DC, 7-8.5 watt AC nominal power. Mini DIN style
connector; NEMA 4/IP65 protection. See Options on page 14.
Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges.
Flow: See page 19.
Options: See pages 14 & 15.
DIMENSIONS SHOWN IN INCH
MM
1.76
44.7
PG-9 CORD GRIP
1/8 NPT ADAPTER
1/2⬙ NPT CONDUIT
CONNECTION
OPTIONAL 1/8ⴖ NPT
ADAPTER
N O
N O
24ⴖ (61 cm LEADS)
24ⴖ (61 cm LEADS)
2.94
74.6
2.25
57.2
1.09
27.8
PARAMUS, NJ
NC
OPTION-228L
#8-32UNC-2B
THD.
.875
22.2
.296
7.5
.296
7.5
.56
14.3
1.13
28.6
CL
COM
OPTION -243
.198
5.0
1/8 NPT
PORTS
.198
5.0
(STANDARD DIN STYLE COIL & CONNECTOR)
10
PARAMUS, NJ
NC
COM
SIDE PORTED VALVES
Type
TWO-WAY, 2/2
NORMALLY CLOSED
Air, Oil or Water
Maxumum Operating
Pressure Differential1
psi (bar)
500 (34)
400 (27)
200 (14)
150-100 (10-6.8)
65-45 (4.4-3.1)
Product Number with
Micromini DIN Style Connector
(8mm gap). For Other Options
See Page 14
EZ-2120-0-HC-(*)
EZ-2130-0-HC-(*)
EZ-2140-0-HC-(*)
EZ-2160-0-HC-(*)
EZ-2180-0-HC-(*)
Minimum Orifice Between Ports
“NC”-“COM”
“COM”-“NO”
Piping Arrangement
and Flow Pattern
COM
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
DE-ENERGIZED
ENERGIZED
NC
COM
NC
Port COM = Inlet
Port NC = Outlet
Port COM blocked to Port NC.
TWO-WAY, 2/2
NORMALLY OPEN
Air, Oil or Water
400 (27)
200 (14)
125 (8.6)
40 (2.7)
EZ-2202-H2-HC-(*)
EZ-2203-H2-HC-(*)
EZ-2204-H2-HC-(*)
EZ-2206-H2-HC-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
COM
DE-ENERGIZED
EZ-3122-1-HC-(*)
EZ-3133-1-HC-(*)
EZ-3144-1-HC-(*)
EZ-3166-1-HC-(*)
EZ-3186-1-HC-(*)
200 (14)
150 (10)
100 (6.8)
50 (3.4)
30 (2.1)
THREE-WAY 3/2
NORMALLY CLOSED
(PIPED EXHAUST)
Air, Oil or Water
200 (14)
150 (10)
100 (6.8)
50 (3.4)
30 (2.1)
EZ-3122-H2-HC-(*)
EZ-3133-H2-HC-(*)
EZ-3144-H2-HC-(*)
EZ-3166-H2-HC-(*)
EZ-3186-H2-HC-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
THREE-WAY, 3/2
NORMALLY OPEN
Air, Oil or Water
150 (10)
125 (8.6)
100 (6.8)
50 (3.4)
EZ-3222-H2-HC-(*)
EZ-3233-H2-HC-(*)
EZ-3244-H2-HC-(*)
EZ-3266-H2-HC-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
NO
Port COM = Inlet
Port NO = Outlet
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
MULTIPURPOSE,
3/2
Air, Oil or Water
300-200 (20-14)
200-150 (14-10)
100-75 (6.8-5.2)
75-40 (5.2-2.7)
EZ-7222-H2-HC-(*)
EZ-7233-H2-HC-(*)
EZ-7244-H2-HC-(*)
EZ-7266-H2-HC-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
125 (8.6)
100 (6.8)
65-50 (4.4-3.4)
25 (1.7)
EZ-8222-H2-HC-(*)
EZ-1-HC-(*)
EZ-8244-H2-HC-(*)
EZ-8266-H2-HC-(*)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
ENERGIZED
NO
COM
Port COM blocked to Port NO
NC NO
DE-ENERGIZED
NO
COM
NC
ENERGIZED
COM
COM
Port NC blocked to Port COM;
Port COM connected to Port NO.
DE-ENERGIZED
NO
Port NC = Inlet
Port COM = Outlet
Port NO = Exhaust
NC NO
NC
Port NC connected to port COM;
Port NO blocked.
ENERGIZED
NO
NO
COM
Port NO = Inlet
Port COM = Cylinder Port
Port NC = Exhaust COM
COM
NC
Port NO connected to Port COM;
Port NC blocked.
DIRECTIONAL
CONTROL, 3/2
Air, Oil or Water
NC
NO
COM
Port COM connected to Port NO
THREE-WAY, 3/2
NORMALLY CLOSED
(EXHAUST TO
ATMOSPHERE)
Air Only
COM
Port COM connected to Port NC.
DE-ENERGIZED
NC
Port NO blocked.
Port COM connected to Port NC.
NC NO
ENERGIZED
NO
NO
COM
Port COM = Inlet
Port NO = Outlet I
Port NC = Outlet II
COM
NC
COM
NC
Port COM connected to Port NC;
Port COM connected to Port NO;
Port NO blocked.
Port NC blocked.
NC NO
COM
DE-ENERGIZED
NO
COM
NC
Multi-purpose valves may be
used as Three-Way, NC or ThreeWay, NO or Directional Control
Valves. Two-Way, NC or Two-Way,
NO can be accomplished by
plugging the appropriate port.
ENERGIZED
NO
COM
NOTES:
1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure shown in color is for DC. Vacuum is AC only.
*Specify coil code # from page 17.
NC
11
SERIES EZ
BANTAM
MULTIPLE MANIFOLD TYPE VALVES (2-10 VALVES)
Maximum
Product Number with
Operating Pressure Micromini DIN Style Connector
Differential1
(8 mm gap). For Other Options
psi (bar)
See page 14
Type
TWO-WAY, 2/2
NORMALLY CLOSED
with Common Inlet
Air, Oil or Water
EZM-2130-**-0-HC-(*)
EZM-2140-**-0-HC-(*)
EZM-2160-**-0-HC-(*)
EZM-2180-**-0-HC-(*)
150 (10)
100 (6.8)
60 (4.1)
30 (2.1)
TWO-WAY, 2/2
NORMALLY OPEN
with Common Inlet
Air, Oil or Water
200 (14)
125 (8.6)
40 (2.7)
EZM-2203-**-Z-HC-(*)
EZM-2204-**-Z-HC-(*)
EZM-2206-**-Z-HC-(*)
THREE-WAY, 3/2
NORMALLY CLOSED
(Exhaust to
atmosphere)
with Common Inlet
Air Only
150 (10)
100 (6.8)
50 (3.4)
30 (2.1)
EZM-3133-**-1-HC-(*)
EZM-3144-**-1-HC-(*)
EZM-3166-**-1-HC-(*)
EZM-3186-**-1-HC-(*)
THREE-WAY, 3/2
NORMALLY CLOSED
(PIPED EXHAUST)
with Common Inlet
& Common Exhaust
Air, Oil or Water
150 (10)
100 (6.8)
50 (3.4)
30 (2.1)
THREE-WAY, 3/2
NORMALLY OPEN
with Common Inlet
& Common Exhaust
Air, Oil or Water
125 (8.6)
100 (6.8)
50 (3.4)
MULTIPURPOSE, 3/2
with Common
“NC” Port
(See Also Note @)
Air, Oil or Water
100 (6.8)
65-50 (4.4-3.4)
25 (1.7)
Minimum Orifice
Between Ports
“NC”-“COM”
“COM”- “NO”
Piping Arrangement
“NC” port = Common Inlet for all valves
“COM” port = Individual Outlet for each valve
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
“NO” port = Common Inlet for all valves
“COM” port = Individual Outlet for each valve
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
“NC” port = Common Inlet for all valves
“COM” port = Individual Outlet for each valve
“NO” port - Individual Exhaust for each valve
EZM-3133-**-Z-HC-(*)
EZM-3144-**-Z-HC-(*)
EZM-3166-**-Z-HC-(*)
EZM-3186-**-Z-HC-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
1/8” (3.2 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/32” (2.4 mm)
“NC” port = Common Inlet for all valves
“COM” port = Individual Outlet for each valve
“NO” port - Common Exhaust for all valves
EZM-3233-**-Z-HC-(*)
EZM-3244-**-Z-HC-(*)
EZM-3266-**-Z-HC-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
“NO” port = Common Inlet for all valves
“COM” port = Individual Outlet for each valve
“NC” port - Common Exhaust for all valves
EZM-8233-**-@-HC-(*)
EZM-8244-**-@-HC-(*)
EZM-8266-**-@-HC-(*)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
The table below lists all the possible valve functions
which can be obtained by just changing the
connections.
Port
N.C.
N.O.
COM
2-Way 2-Way
N.O.
N.C.
3-Way
N.O.
3-Way
N.C. Selector Diverter
Inlet
Plug Inlet Exhaust Inlet
Exhaust Inlet
Inlet Plug Inlet
Outlet Outlet
Outlet Outlet Outlet
Outlet
Outlet
Inlet
NOTES:
1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure shown in color is for DC.
*Specify coil code # from page 17.
**Specify number of valve stations required, 2 thru 10.
@ “NO” Port variations available:
—1—
“NO” valve ports are unpiped and exchange to atmosphere.
—H2— Each “NO” valve port is provided with a 1/8” NPT adapter for piping each “NO” port individually.
—Z—
“NO” ports of all valves are connected to a common “NO” port in the manifold.
3.6
90.5
DIMENSIONS SHOWN IN INCH
MM
1.75
44.5 1.0
25.4 .25
6.4
12
3.06
77.8
.196
5 MOUNTING HOLE (2)
.375
9.5
1.14
29
N.C.
4.0
102
(3 STATION OVERALL LENGTH.)
1.0
1.0
25.4
25.4
C
C
C
L #1
L #2
L #3
.375
9.5
.25
6.4
N.O.
Typical Multiple Manifold
(Shows common “NO” port arrangement and micromini DIN style connector)
1/8ⴖ NPT PORTING
(Both Ends)
1/8ⴖ NPT PORTING
.375
9.5
1
2.8
71.4
.5
12.7
PG-9 CORD GRIP
COM
COM
COM
ELECTRIC QUICK
EXHAUST VALVES
(For Pneumatic Application Only)
Functional Description
Construction
The Electric Quick Exhaust Valve is a three-way, NC, 3/2 valve
with extra large exhaust orifice in order to provide extra fast
movement of the cylinder rod, or to exhaust systems rapidly.
When the solenoid is energized the outlet port is connected to
the inlet port and the exhaust port is closed. When the solenoid
is de-energized the inlet port is closed and the outlet port is
connected to the exhaust port, providing rapid evacuation of the
system.
Body: 316 stainless steel. (Conforms to NACE standard MR-01-75)
Solenoid Operator: 304, 430F & 302 stainless steel (wetted parts)
Seals: FKM (fluorocarbon) O ring seals;
CR (neoprene) coated nylon flapper.
Screws: stainless steel
TYPES
SERIES E5
SERIES E
E5QE
EQE
BASIC VALVE PRODUCT NUMBER BASIC VALVE PRODUCT NUMBER
Function
Non-Hazardous Location Solenoids
(See SUFFIX OPTIONS below for
Hazardous Locations)
(See SUFFIX OPTIONS below for
Hazardous Locations)
E5 Series
E Series
Operating
Pressure PSI
(bar)
1/4” NPT Inlet
1/4” Outlet &
3/8” NPT Exhaust
1/4” NPT Inlet
1/2” Outlet &
3/4” NPT Exhaust
1/4” NPT Inlet
1/2” Outlet &
3/4” NPT Exhaust
1/4” Quick Exhaust
5-150 (0.3 -10)
5-100 (0.3 -6.9)
E5QE-30304-316-*-**
E5QE-30404-316-*-**
-----------------------------------
-----------------------------------
.06 (.87)
.106 (1.5)
3.3 (48)
3.3 (48)
1/2” Quick Exhaust
5-150 (0.3 -10)
5-100 (0.3 -6.9)
-----------------------------------
E5QE-50304-316-*-**
E5QE-50404-316-*-**
EQE-50304-316-*-**
EQE-50406-316-*-**
.06 (.87)
.106 (1.5)
8.8 (128)
8.8 (128)
Basic Size
3-Way, 3/2,
Normally Closed
**Specify any Suffix Options listed below (description on pages 14, 15 & 16).
E5QE SUFFIX OPTIONS
Standard, none req.
-PC (page 14)
Flow Cv (Kv)
Inlet
Exhaust
** Specify Coil Code from page 17.
EQE SUFFIX OPTIONS
SOLENOID OPERATOR
(Non-Hazardous Locations)
-----------------------------------
NEMA 1, 1/2 NPT Conduit Entry
NEMA 4, 1/2 NPT Conduit Entry
SOLENOID OPERATOR
(Hazardous Locations, page 16)
-XX
-LB-XX
-PC-XX
-ST-XX
UL/CSA, 1/2 NPT Conduit Entry
w/ (Low Watt)
w/ (Potted Coil)
w/ (Stainless Steel Coil Housing)
-XN
-LB-XN
-PC-XN
-ST-XN
ATEX, M20 x 1.5 Conduit Entry
w/ (Low Watt)
w/ (Potted Coil)
w/ (Stainless Steel Coil Housing)
-HC-XISC
-HCC-XISC
+++FACTORY MUTUAL/CSA
Intrinsic Safe, DIN connector
w/ Pg9 Cord Grip
w/ 1/2 NPT Conduit Entry
-HC-XISX6
-HCC-XISX6
+++ATEX, Intrinsic Safe (ia),
DIN connector
w/ Pg9 Cord Grip
w/ 1/2 NPT Conduit Entry
+++IMPORTANT NOTE - Consult Factory. All above Intrinsic Safe Operators
require respective product number change to:
E5QE-30202-316-*-D024 (1/4” NPT Basic Size) or
E5QE-50202-316-*-D024 (1/2” NPT Basic Size)
Operating Pressure is 5-115 PSI (0.3-7.9 bar)
Inlet Flow for each is 0.2 Cv (.32 Kv).
ATEX, Flameproof (d),
Integral Junction Box
w/ M20 x 1.5 Conduit Entry
w/ 1/2 NPT Conduit Entry
-XDAS
-XDAT
ATEX, Flameproof (d),
Encapsulation (m), Increased Safety (e)
Integral Junction Box
w/ M20 x 1.5 Conduit Entry
w/ 6-12 mm Cable Gland
w/ 1/2 NPT Conduit Entry Adapter
w/ 9-16 mm Cable Gland
-XMAA
-XMAE
-XMAF
-XMAG
ATEX, Intrinsic Safe (ib),
Integral Junction Box
w/ M20 x 1.5 Conduit Entry
w/ 6-12 mm Cable Gland
w/ 1/2 NPT Conduit Entry Adapter
-XIFA
-XIFE
-XIFF
13
SERIES E
TYPE VALVES
OPTIONS
(Add designation to product number in alpha-numeric order)
COILS – see page 17 (Series E Fullsize, Series E5 Compact, Series EZ Bantam)
COIL HOUSINGS FOR NONHAZARDOUS SERVICE VALVES:
(FOR HAZARDOUS SERVICE VALVES SEE PAGE 16)
Suffix Detail
-HC
DIN type 3 prong coil with quick
disconnect. Includes female
socket with cord grip. NEMA
4I IP65 protection. Series E
fullsize, Electrical Quick Exhaust.
-HCC
DIN type 3 prong coil with quick
disconnect. Includes female
socket with 1/2” NPT conduit
connection. NEMA 4/IP65
protection. Series E fullsize, E5
compact, EZ bantam, Electrical
Quick Exhaust.
-228L
Coil & 1/2” NPT conduit
connection integrally molded in
epoxy. 24” (61 cm) lead length.
NEMA 4/IP65 protection.
Series EZ bantam.
-243
Grommeted lead housing. 24”
(61 cm) lead length. NEMA 1, 2, 3
protection. Series E fullsize.
Electrical Quick Exhaust.
Flying leads; 24” (61 cm) length.
NEMA 1, 2, 3 protection.
Series EZ bantam.
SEALS (See also “Solenoid Operators for
Special Conditions”, -3.)
-HCCL
DIN type 3 prong coil with quick
disconnect. Includes female
socket with 1/2” NPT conduit
connection, and indicator light
when power is on coil. NEMA
4I IP65 protection. Series E
fullsize, E5 compact, EZ bantam,
Electrical Quick Exhaust.
Suffix Detail
-155
-EP
-HCL
DIN type 3 prong coil with quick
disconnect. Includes female
socket with cord grip and
indicator light when power is on
coil. NEMA 4/IP65 protection.
Series E fullsize, E5 compact, EZ
bantam, Electrical Quick
Exhaust.
FKM (fluorocarbon) per ASTM D1418/ISO-1629, Equips valve with
all seals of fluorocarbon (includes
suffix -3). Use suffix only for
manifold mounting valve when all
fluorocarbon seals are required.
Series E fullsize.
EPR (ethylene propylene) seals
(gray/gray) for use with some
synthetic oils. Consult factory.
Series E fullsize, E5 compact,
Electrical Quick Exhaust.
For other seal materials consult factory.
MANUAL OVERRIDE
(Series E fullsize only)
Suffix Detail
Suffix -M
-PC
Potted coil for nonhazardous
service; coil epoxy encased
within housing. NEMA 4/IP65
protection. Series E fullsize, E5
compact, Electrical Quick
Exhaust. For Hazardous service
see page 15 “Options For
Special Conditions”.
Suffix -MAE
14
-G5R
Guarded type, holding. Requires
screwdriver to operate.
-M
Guarded type, non-holding.
Requires probe to operate.
-M5R
Unguarded type, holding. Has
knurled knob.
-MAE
Unguarded type. Push to operate.
SERIES E
OPTIONS
TYPE VALVES
(Add designation to product number in alpha-numeric order)
FLOW Series E fullsize
Suffix Detail
MOUNTING BRACKETS Series E fullsize
(Side-ported valves only)*
-A
Adjustable Metering Exhaust
Adapter, provides metering of
exhaust flow on Three-Way NC
valves. (See -N for Three-Way NO.)
Supplied with 1/16” NPT threaded
port for pipe connection. Series E
fullsize.
Suffix Detail
-WE
Wall mounting bracket attached
to coil housing. Mounting holes
on 2-1/8” (54 mm) centers. (Not
for Hazardous Service Valves.
See -WEX.)
Adjustable Metering Inlet Flow
(Three-Way NC)
Adjustable Metering Outlet Flow
(Two-Way NC)
Adjustable Exhaust (Three-Way NO)
(On side-ported models the
adjusting needle is located in the
side of the valve body. On manifold
mounting models a separate
Adapter Plate, E-112-A, is required
for mounting between the valve and
the manifold. The Adapter Plate
contains the adjustable needle.
Therefore, the suffix “-N” is not
required as part of the valve product
number, and the Adapter Plate is
specified separately.) Series E
fullsize.
-WEX
Wall mounting bracket attached
to valve body. Mounting holes on
2” (51 mm) centers. (Required for
Hazardous Service Valves when
wall mounting bracket is desired.
Cannot be used when valves
have suffix detail -N.)
-N
*All side-ported valves may be
line mounted or mounted by
using the 10-32 mounting holes
in the bottom of the valve body.
A Bottom Mounting Bracket,
(part no. A-4222-B) with
mounting holes on 2” (51 mm)
centers can also be supplied, but
must be ordered separately.
1.97ⴖ
50 mm
1.13ⴖ
28.7 mm
1.13ⴖ
28.7 mm
1.06ⴖ
26.9 mm
1.06ⴖ
26.9 mm
Suffix -WE
OPTIONS FOR SPECIAL CONDITIONS
Suffix Detail
Suffix Detail
-HT
SOLENOID OPERATOR WITH CLASS H COIL: For UL
or CSA approval, consult factory. Recommended for
all applications above 150ºF (65ºC) and for DC
continuous duty above 120ºF (50ºC). Includes suffix
-3. Not for use with suffix -P. Series E fullsize,
E5 compact, Electrical Quick Exhaust.
-3
-ST
Stainless steel (182 FM) coil housing with 1/2” NPT
conduit connection. For hazardous service valves
only. Series E5 compact, Series E5, Electrical Quick
Exhaust.
-PS
Potted coil for hazardous service valves. Coil and
wires sealed at factory. Provides 1/2” NPT conduit
connection. Series E fullsize or Series E Electrical
Quick Exhaust. For Series E5 compact or Series E5
Electrical Quick Exhaust use -PC.
CONTINUOUS DUTY SOLENOID AND/OR HIGH AMBIENT OR MEDIA TEMPERATURE: FKM (Fluorocarbon)
seals (TAN/TAN); recommended when coil may be
energized for long periods and/or when ambient or media
temperature will exceed 120ºF (50ºC). Ordinary Locations:
Series E fullsize and Series E Electrical Quick Exhaust,
Series E5 compact and Series E5 Electrical Quick Exhaust.
Hazardous Locations: option is included.
DUST EXCLUDER NUT FOR SOLENOID EXHAUST
Non-Hazardous Service
Hazardous Service
Series E fullsize
& Series E Electrical
Quick Exhaust
-14
-E14
Series E compact
& Series E5 Electrical
Quick Exhaust
-L14
-L14
Series EZ bantam
-L14
n/a
15
16
Class I Groups C & D,
Area Classification
and (Gas Grouping)
(ia) Intrinsic Safe
Intrinsic Safe
(mb) Encapsulation
(e) Increased Safety
(tD) Tight Dust
(d) Flameproof
II 2 G EEx ia IIC T4 to T6
II 2 G EEx ia IIC T6
Class I, Groups (A, B, C & D)
Class II, Groups (E, F, &G)
Class III, Division 1
II 2 G Ex e mb II T5, T6
II 2 D Ex tD A21 T100ºC, T85ºC
Ex e mb II T5, T6 Gb
Ex tD A21 T100ºC T85ºC Db
II 2 G Ex d IIC T4 to T6
ATEX
Factory Mutual
CSA
ATEX
IECEx
ATEX
IECEx
ATEX
Ex d IIC T4 to T6 Gb
IECEx
II 2 G Ex d IIB+H2 T3 to T6
UL
CSA
Certification
(Conformance)
Ex d IIB+H2 T3 to T6 Gb
Class II, Divison 2, Groups E, F & G; T3C;
Hazardous Locations Class I, Division 2, Groups A, B, C & D;
Protection
Classification
IP66 & IP67
IP65
IP66 & IP67
IP66 & IP67
IP66 & IP68
NEMA 7 & 9
Ingress
Protection
24VDC (0.8W)
(Consult factory for other
voltages)
24VDC system voltage
prior to barrier (1.6 watt
max.)
24VDC system voltage
prior to barrier (1.6 watt
max.)
(Consult factory for other
voltages)
24VDC (10W inrush,
2.6W holding)
24VDC (4W)
(Consult factory for other
voltage options)
50 Hz and 60 Hz
AC (10W)
DC (10W), except 24V50
and 230V50 (6W)
60 Hz
AC (1.8W)
DC (1.8W)
50 Hz and 60 Hz
AC (5.6W)
DC (7.2W)
60 Hz
AC (1.8W)
DC (1.8W)
50 Hz & 60 AC (Series E:
7.3W Series E5: 5.6W)
DC (Series E: =9.5W
and Series E5:7.2W.)
Voltage
(Power)
Continuous duty.
Coil and power controller
potted, within housing.
Class F epoxy molded coil
(155ºC) Continuous duty.
Class F epoxy molded coil
(155ºC) Continuous duty
Continuous duty. Coil & power
potted within housing.
Continuous duty. Coil &
Rectifier,
including surge suppression,
potted within housing.
Class F epoxy molded coil
(155ºC) Continuous duty.
Class F epoxy molded coil
(155ºC) Continuous duty.
3 leads 24” (60 cm).
Class F epoxy molded coil
(155ºC) Continuous duty.
3 leads 24” (60 cm).
Class F epoxy molded coil
(155ºC) Continuous duty.
3 leads 24” (60 cm).
Class F epoxy molded coil
(155ºC) Continuous duty. 3
leads 24” (60 cm)
Electrical
Characteristics
*See page 17 for available Voltages and Coil Code.
**Consult factory for pressure rating when using XIF_ coils
NOTE: Option -HC-XISC, -HCC-XISC, -HC-XISX6 and -HCC-XISX6 are only available with 3-way NC valves with 1/32” (0.08 mm) orifice, and maximum pressure 115 psi (7.8 bar).
-XIFF
**(Series E)
-XIFE
-XIFA
(Series E5)
See important note
below chart
-XISX6
(Series E5)
See important note
below chart
-XISC
-XMFG
(Series E)
-XMFF
-XMFE
-XMFA
-XMAG
(Series E)
-XMAF
-XMAE
-XMAA
-XDAT
(Series E)
-XDAS
(Series E5)
-LB-XN
(Series E5)
-XN
(series E)
-LB-XX
(series E & E5)
-XX
Suffix
Identification
HAZARDOUS LOCATION SOLENOIDS
Requires the use of an approved safety
barrier or isolator.
Thick wall epoxy coil housing and integral
junction box. Internal ground terminal.
M20 x 1.5 conduit entry; (-XIFA)
Cable gland for 6-12 mm ø cable: (-XIFE)
1/2 NPT conduit entry with adapter: (-XIFF)
Requires the use of an approved barrier or isolator.
Maximum operating system voltage before barrier 28VDC.
Maximum pilot pressure 115 psi (8 bar)
3 spade terminals & DIN connector with PG9
cable gland; (-HC)
1/2 NPT conduit entry: (-HCC)
Requires the use of an approved barrier or isolator.
Maximum operating system voltage before barrier 28VDC.
Maximum pilot pressure 115 psi (8 bar)
3 spade terminals & DIN connector with PG9
cable gland; (-HC)
1/2 NPT conduit entry: (-HCC)
Thick wall epoxy coil housing with integral junction
box. Internal ground terminal.
M20 x 1.5 conduit entry: (-XMFA)
Cable gland for 6-12 mm ø cable: (-XMFE)
1/2 NPT conduit entry with adapter: (-XMFF)
Cable gland for 9-16 mm ø cable: (-XMFG)
Thick wall epoxy coil housing with integral junction box.
Internal ground terminal.
M20 x 1.5 conduit entry: (-XMAA)
Cable gland for 6-12 mm ø cable: (-XMAE)
1/2 NPT conduit entry with adapter: (-XMAF)
Cable gland for 9-16 mm ø cable: (-XMAG)
Stainless Steel coil housing with internal Junction
Box. Internal and external ground screw.
M20 x 1.5 conduit entry: (-XDAS)
1/2 NPT conduit entry: (-XDAT).
Steel Chromate plated coil housing
with M20 x 1.5 conduit entry. Ground terminal on cover.
For stainless steel (182 FM) cover add: -ST.
Maximum pilot pressure 120 psi (8 bar).
1.8W nominal power.
Steel Chromate plated coil housing
with M20 x 1.5 conduit entry. Ground terminal on cover.
For stainless steel (182 FM) cover add: -ST..
Steel Chromate plated coil housing
with 1/2 NPT conduit entry. For stainless steel (182 FM)
coil housing add: -ST.
Maximum pilot pressure 120 psi (8 bar).
1.8W nominal power.
Steel Chromate plated coil housing
with 1/2 NPT conduit entry. For (182FM)
stainless steel cover add: -ST
Miscellaneous
SOLENOID OPERATORS FOR HAZARDOUS SERVICE
SERIES E
TYPE COILS
CONTINUOUS DUTY COIL VOLTAGES1
SERIES E FULLSIZE & SERIES E Electrical Quick Exhaust
Solenoid Operator
information
Nominal Coil Power
AC
2NC = 7.7W
2NO, 3-Way,
Directional,
Multi-Purpose
= 8.7W
Ordinary Location
9.5W
All coils are
Class F
epoxy
Molded.2
Hazardous Location
(Suffix -XX) UL Listed Rated voltge
or CSA certified. continuous
duty 100%
Ordinary Location
DIN Style Coil &
Connector
(Suffix -HC, -HCC,
-HCCL, -HCL
7.3W
Coil Voltages
DC
AC
DC
Voltage
Coil Code #
Inrush
Amp
Holding
Amp
Ohm
24/60
120/60
240/60
480/60
A024
A120
A240
A480
1.30
0.26
0.13
0.07
0.82
0.16
0.08
0.04
5.8
146
593
2365
24/50
110/50
230/50
240/50
E024
F120
E230
E240
1.05
0.23
0.11
0.11
0.67
0.15
0.07
0.07
8.5
193
700
876
120/60
240/60
110/50
220/50
A120
A240
E110
E220
0.20
0.13
0.20
0.13
0.16
0.08
0.16
0.08
205
845
205
845
Voltage
Coil Code # Inrush &
Holding
Amp
Ohm
6
12
24
48
125
D006
D012
D024
D048
D125
1.54
0.78
0.38
0.19
0.08
3.9
15.5
63
249
1675
12
24
48
D012
D024
D048
0.86
0.44
0.21
14
55
225
9.5W
2NC = 7.7W
12W
10W
SERIES E5 COMPACT & SERIES E5 Electrical Quick Exhaust
Solenoid Operator
information
Ordinary Location
AC
6W
Hazardous Location
(Standard Wattage
Suffix -XX & -XN) All coils are
UL Listed or CSA Class F epoxy
certified. molded.2
Hazardous Location
(Low Wattage
Suffix -LB-XX & -LB-XN)
UL Listed or
CSA certified.
Nominal Coil Power
Rated
voltage
continuous duty
100%.
Ordinary Location
DIN Style Coil &
Connectors
(Suffix -HC, -HCC,
-HCCL, -HCL)
2NC = 4W
2NO, 3-Way,
Directional,
Multi-Purpose
= 5.6W
1.8W
8.5W
Coil Voltages
DC
AC
DC
Voltage
Coil Code #
Inrush
Amp
Holding
Amp
Ohm
24/60
120/60
240/60
480/60
A024
A120
A240
A480
0.63
0.13
0.06
0.03
0.38
0.08
0.04
0.02
19
475
2000
8460
24/50
110/50
220/50
240/50
E024
E110
E220
E240
0.61
0.13
0.07
0.06
0.37
0.08
0.04
0.04
25
475
2030
2714
12/60
24/60
48/60
120/60
240/60
A012
A024
A048
A120
A240
0.58
0.29
0.14
0.06
0.03
0.30
0.15
0.07
0.03
0.02
11
43
175
1085
5050
24/60
120/60
240/60
A024
A120
A240
0.63
0.13
0.06
0.05
0.10
0.05
26
647
2790
110/50
220/50
240/50
E110
E220
E240
0.13
0.06
0.06
0.10
0.05
0.05
647
2790
3058
Voltage
7W
7.2W
1.8W
10.5W
Coil Code # Inrush &
Holding
Amp
Ohm
6
12
24
47
125
D006
D012
D024
D047
D125
1.30
0.63
0.32
0.16
0.06
4.6
19
75
295
2030
6
12
24
48
120
D006
D012
D024
D048
D120
10.32
0.16
0.08
0.04
0.02
19
75
312
1337
7815
12
24
48
D012
D024
D048
0.86
0.44
0.22
14
55
222
NOTES
1. Many voltages, other than those listed, are available. Consult factory for delivery and technical information.
2. Class H coils are available for both ordinary and hazardous locations. Consult factory.
SERIES EZ BANTAM
Solenoid Operator
information
Nominal Coil Power
AC
Non-hazardous
All coils are
Standard (DIN style)
Class F
NEMA 4
epoxy
Molded.
Also Suffix:
-HCC
Rated voltge
-HCCL
continuous
-HCL
duty 100%
-243
-228L
Coil Voltages
DC
AC
DC
Voltage
Coil Code #
Inrush
Amp
Holding
Amp
Ohm
24/60
120/60
240/60
A024
A120
A240
0.63
0.13
0.06
0.50
0.10
0.05
26
647
2790
110/50
220/50
240/50
E110
E220
E240
0.13
0.06
0.06
0.10
0.05
0.05
647
2790
3058
Voltage
2NC = 7W
8.5W
10.5W
12
24
48
Coil Code # Inrush &
Holding
Amp
D012
D024
D048
0.87
0.43
0.22
Ohm
14
55
222
17
SERIES E
OPTIONS & AVAILABILITY
Selector Chart & Option Availability for Series E Type Valves
PORT SIZE
SERIES E fullsize
& SERIES E
Electrical Quick Exhaust
SERIES E5 compact
& SERIES E5
Electrical Quick Exhaust
1/8NPT, 1/4NPT
1/8NPT
1/8NPT
1/4NPT
na
1/8NPT
NC
vacuum to 250 psi (17 bar)
vacuum to 500 psi (34 bar)
vacuum to 500 psi (34 bar)
NO
vacuum to 200 psi (14 bar)
vacuum to 400 psi (27 bar)
vacuum to 400 psi (27 bar)
NC
vacuum to 150 psi (10 bar)
vacuum to 200 psi (14 bar)
vacuum to 200 psi (14 bar)
NO
vacuum to 150 psi (10 bar)
vacuum to 150 psi (10 bar)
vacuum to 150 psi (10 bar)
Directional
vacuum to 200 psi (14 bar)
vacuum to 300 psi (21 bar)
vacuum to 300 psi (21 bar)
Multipurpose
vacuum to 150 psi (10 bar)
vacuum to 125 psi (8.6 bar)
vacuum to 125 psi (8.6 bar)
.06-.79 (0.9-11.5)
.022-.23 (0.3-3.3)
.022-.23 (0.3-3.3)
stainless steel
stainless steel
aluminum
aluminum
na
aluminum
aluminum
na
na
7.3-8.7 AC, 9.5 DC
6-10.5 AC, 7 DC
7-8.5 AC, 10.5 DC
Sideported
Manifold
PRESSURE RANGE
psi (bar)
2-Way
3-Way
FLOW RANGE CV(KV)
CONSTRUCTION
Body
Sideported
Manifold MTG
Manifold
NOMINAL POWER (watt)
ELECTRICAL CONNECTION/
COIL COVER
1/2” NPT Conduit entry
std
std
-228L
Grommeted (flying leads)
-243
-243
-243
DIN coil & cable gland connector
-HC
-HC
std
DIN coil & 1/2” NPT conduit entry
-HCC
-HCC
-HCC
DIN coil & 1/2” NPT conduit entry
with indicator light
-HCCL
-HCCL
-HCCL
DIN coil & cable gland connector
with indicator light
-HCL
-HCL
-HCL
Ordinary service
-PC
-PC
na
Hazardous service
-PS
-PC
na
Potted coil
SEALS
NBR-nitrite (Buna N)
std
std
na
FKM (fluorocarbon)
-3 (sideported); -155 (manifolded)
std (hazardous locations)
-3 (ordinary locations);
std (hazardous locations)
std
EPR-ethylene propylene
FLOW OPTIONS
MANUAL OVERRIDE
Adjustable metering exhaust
-EP
-EP
na
3-Way NC
-A
na
na
3-Way NO
-N (1/4 NPT only)
na
na
Adjustable metering inlet
3-Way NC
-N (1/4 NPT only)
na
na
Adjustable metering outlet
2-Way NC
-N (1/4 NPT only)
na
na
Guarded
holding
-G5R
na
na
-M
na
na
holding
-M5R
na
na
push
-MAE
na
na
na
na
nonholding
Unguarded
MOUNTING BRACKETS
(sideported only)
Wall mounting
-WE (ordinary locations)
-WEX (hazardous locations)
Base mounting
Part #A-4222-B Bracket
na
na
OPTIONS FOR
SPECIAL CONDITIONS
High ambient temperature and/or
Continuously energized coil
-3
-3 (ordinary locations)
std (hazardous locations)
std
Class H coil
-HT
-HT
na
Silencer/dust excluder for solenoid exhaust
-14
-L14
-L14
Std. Wattage
-XX
-XX
na
na
-LB-XX; (1.8W)
na
na
-XN
na
na
-LB-XN; (1.8W)
na
na
-ST
na
S
O
L
E
N
O
I
D
O
P
E
R
A
T
O
R
S
Hazardous location
(d) Flameproof
H
A
Z
A
R
D
O
U
S
S
E
R
V
I
C
E
*
Low-Watt
Std. Wattage
Low Watt
UL & CSA approved
ATEX approved
Stainless steel coil covers
for Hazardous service & (d) Flameproof operators above
(d) Flameproof
F
O
R
(me) Encapsulation
(e) Increased Safety
Hazardous location
(Ia) Intrinsic Safe
(ib) Intrinsic Safe
*See Page 16
18
SERIES E bantam
Standard
Wattage
ATEX approved
-XDAS, -XDAT
na
na
Standard
Wattage
ATEX approved
-XMAA, -XMAF
-XMAE, -XMAG
na
na
-XMFA, -XMFF
-XMFE, -XMFG
na
na
FM & CSA approved
na
-HC-XISC
-HCC-XISC
na
ATEX approved
na
-HC-XISX6
-HCC-XISX6
ATEX approved
-XIFA, -XIFE, -XIFF
na
Standard
Wattage
na
SERIES E
TYPE VALVES
FLOW DATA
250
200
Series E Fullsize
LE
T
PR
ES
SU
RE
–
PS
125
100
75
50
30
I
75
50
25
3
0
20
20
10
3
1
/64
40
20
10
5
/16
FINAL PRESSURE – PSI
60
40
30
10
2
60
40
20
5
80
50
15
4
100
80
60
20
10
6
150
1
/32
PRESSURE DROP – PSI
IN
8
70
40
25
15
225
200
175
150 125 100
1
/ 16 3/ 32 1/ 8 5/ 323/ 16 1/ 4
ORIFICE – INCH
100
30
10
250
25
250 225 200 175
3
/ 64
AIR FLOW IN CFM AT 70º F
5
/8
3
/32
50
10
5
1
/16
/4
ORIFICE – INCH
1
0.1
0.2
0.5
1
2
5
10
20
WATER FLOW – G.P.M.
Series E5 Compact
AIR FLOW RATE IN CFM AT 70º F
6
400
5
12
T
PR
ES
SU
15
RE
–
PS
I
250
200
150
100
4
50
/32
20
10
5
3
/64
1
/16
3
1
/32
/8
3
/ 32
1
/8
ORIFICE – INCH
50
10
5
ORIFICE – INCH
1
0.1
0.2
0.5
1
2
5
WATER FLOW – G.P.M.
AIR FLOW RATE IN CFM AT 70º F
6
400
350
IN
T
PR
250
ES
SU
200
RE
–
PS
200
12
4
10
150
100
8
3
6
150
I
250
14
5
300
LE
300
30
2
1
Series EZ Bantam
350
20
10
5
1
0
40
15
2
FINAL PRESSURE – PSI
400
10
6
150
25
/ 16
/ 64
100
8
3
200
1
3
/ 32
50
PRESSURE DROP – PSI
LE
300
1
35
20
10
4
250
50
350
400
60
30
300
100
400
40
40
35
20
30
25
15
20
10
15
2
100
50
50
25
4
1
0
FINAL PRESSURE – PSI
2
/32 3/64
1
5
1
/16
ORIFICE – INCH
Flow Factors for various orifice sizes
400
10
5
1
/ 32
3
/32
1
3
/ 16
/ 64
3
/ 32
ORIFICE – INCH
100
PRESSURE DROP – PSI
IN
350
25
14
50
10
5
Orifice
1/32” (0.8 mm)
3/64” (1.2 mm)
1/16” (1.6 mm)
3/32” (2.4 mm)
Cv
.022
.06
.106
.21
Kv
.32
.87
1.5
3.1
Orifice
1/8” (3.2 mm)
5/32” (4.0 mm)
3/16” (4.8 mm)
1/4” (6.4 mm)
Cv
.26
.45
.56
.79
Kv
3.8
6.5
8.1
11.5
1
0.1
0.2
0.5
1
2
5
WATER FLOW – G.P.M.
19
IF YOU HAVEN’T FOUND THE VALVE YOU NEED,
YOU HAVEN’T ASKED US.
Versa Valves… designed, built, and tested
to meet your air requirements.
SERIES “B” VALVES:
1/8” NPT, 3/16” (4.7mm) Orifice. Two- & Three-Way. Brass & SS
Construction. Manual, Pilot & Cam Actuation. Pneumatic Service
Vacuum to 200 psi (14 bar).
Bulletin B.
SERIES “B-316”, “B-900” & “B-550” AUTOMATION
AND CONTROL VALVES & COMPONENTS FOR
PROCESS CONTROL:
Suitable for Offshore, Process Control, Material Specs Meet NACE
MR-01-75. Fluorocarbon Seals, 1/4” NPT, 3/16” (5mm) Orifice.
Three-Way. Solenoid/Pilot, Remote Pilot, Mechanical, Manual &
Many Special Actuators. Main Supply Reset Valves; First Out
Indicating Valves. Pneumatic Service Vacuum to 200 psi (14 bar).
Bulletin B316
SERIES “C” VALVES:
Fluorocarbon Seals. Solenoid/Pilot, Remote Pilot, Cam & Manual
Actuation. Pneumatic Service Vacuum to 175 psi (12 bar).
Bulletin K.
SERIES “H” VALVES:
High pressure hydraulic valves: High pressure valves for the Oil &
Gas Industry; to 10,000 psi operating pressure, 316 stainless steel
construction, leakproof, balanced dynamic ceramic sealing, O ring
static seals, modular design, manifold mounting.
Bulletin H
SERIES “V” & “T” VALVES:
1/8” thru 1-1/4” NPT or G, Full Ported, Two-, Three-, Four- & FiveWay, Selector, Diverter. All types of Actuation. Forged Brass
Construction. Pneumatic Service Vacuum to 200 psi (14 bar),
Hydraulic Service to 500 psi (35 bar).
Bulletin VT.
10-32 (M5), 1/8” NPT OR G1/8”, 1/4” NPT OR G1/4, 0.6 to 7mm
Orifice. Three- & Four-Way, Multi-purpose. Individual Mount,
Stacking, or Manifold Mounted. Aluminum, SS & Nylon Construction.
Solenoid/Pilot, Pilot, Manual & Mechanical Actuation. Pneumatic
Service Vacuum to 115 psi (8 bar).
Bulletin C.
SERIES “V-316” STAINLESS STEEL VALVES:
SERIES “E” VALVES:
SOLENOID VALVES FOR THE PROCESS CONTROL
INDUSTRY:
1/8” NPT & 1/4” NPT. 1/32” (0.8mm) thru 1/4” (6.4mm) Orifice. Two& Three-Way, Directional, Multi-Purpose. Sideported, and Manifold
Mounted. SS or Aluminum Construction. Direct Solenoid Actuation,
including LOW WATT. Pneumatic & Hydraulic Service Vacuum to
500psi (35 bar).
Bulletin E.
Suitable for Offshore, Process Control, Material Spec Meet NACE
MR-01-75. Fluorocarbon Seals. 1/4”, 3/8”, 1/2” NPT, Full Ported.
Two-, Three-, Four- & Five-Way. Selector. Diverter. All Type of
Actuation. Pneumatic Service Vacuum to 200 psi (14 bar).
Bulletin V316.
Complete Range of Stainless Steel, Brass or Aluminum Constructed
Valves, 1/8” NPT through 1 NPT. Direct NAMUR Mount & Bodyported
Styles. Latching Manual Reset, Lockout Valves, Redundant Valves.
Bulletin PCg.
ACCESSORIES:
SERIES “K” VALVES:
Compact Air Management System. ¼” NPT or G1/4”, 4.7mm &
6.5mm Orifice. Two-, Three-, Four- & Five-Way, Selector, Diverter.
Manifold Mounted, Integrated Circuitry, Aluminum Construction.
Shuttle Valves, Bleed Control Valves, Dust Excluders, Foot Guards,
Bleed Valves, Quick Exhaust Valves, Status Indicators.
Bulletin ACC.
WARNINGS REGARDING THE DESIGN APPLICATION,
INSTALLATION AND SERVICE OF VERSA PRODUCTS
The warnings below must be read and reviewed before designing a system utilizing, installing,
servicing, or removing a Versa product. Improper use, installation or servicing of a Versa product could create a hazard to personnel and property.
DESIGN APPLICATION WARNINGS
Versa products are intended for use where compressed air or industrial hydraulic fluids are
present. For use with media other than specified or for non-industrial applications or other
applications not within published specifications, consult Versa.
Versa products are not inherently dangerous. They are only a component of a larger system.
The system in which a Versa product is used must include adequate safeguards to prevent
injury or damage in the event of system or product failure, whether this failure be of switches,
regulators, cylinders, valves or any other system component. System designers must provide
adequate warnings for each system in which a Versa product is utilized. These warnings,
including those set forth herein, should be provided by the designer to those who will come in
contact with the system.
Where questions exist regarding the applicability of a Versa product to a given use, inquiries
should be addressed directly to the manufacturer. Confirmation should be obtained directly
from the manufacturer regarding any questioned application prior to proceeding.
INSTALLATION, OPERATION AND SERVICE WARNINGS
Do not install or service any Versa product on a system or machine without first depressurizing
the system and turning off any air, fluid, or electricity to the system or machine. All applicable
electrical, mechanical, and safety codes, as well as applicable governmental regulations and
laws must be complied with when installing or servicing a Versa product.
Versa products should only be installed or serviced by qualified, knowledgeable personnel who
understand how these specific products are to be installed and operated. The individual must
be familiar with the particular specifications, including specifications for temperature, pressure,
lubrication, environment and filtration for the Versa product which is being installed or serviced.
Specifications may be obtained upon request directly from Versa. If damages should occur to
a Versa product, do not operate the system containing the Versa product. Consult Versa for
technical information.
LIMITED WARRANTY DISCLAIMER AND
LIMITATION OF REMEDIES
Products sold by Versa are warranted to be free from defective material and workmanship
for a period of ten years from the date of manufacture, provided said items are used in
accordance with Versa specifications. Versa’s liability pursuant to that warranty is limited
to the replacement of the Versa product proved to be defective provided the allegedly
defective product is returned to Versa or its authorized distributor.
Versa provides no other warranties, expressed or implied, except as stated above. There
are no implied warranties of merchantability or fitness for a particular purpose. Versa’s liability for breach of warranty as herein stated is the only and exclusive remedy and in no
event shall Versa be responsible or liable for incidental or consequential damages.
Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey, USA 07652 • 201/843-2400 FAX: 201/843-2931
Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands • 01131-55-3681900 FAX: 01131-55-3681909
www.versa-valves.com