SERIES E TYPE VALVES BULLETIN E-2010 AIR VALVES FOR INDUSTRY SINCE 1949 E Full Size Manifold Mounting — Page 4 Electric Quick Exhaust — Page 13 E5 Compact — Page 6 EZ Bantam — Page 10 E Full Size — Page 2 www.versa-valves.com email: sales@versa-valves.com Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey, USA 07652 • 201/843-2400 FAX: 201/843-2931 Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands • 01131-55-3681900 FAX: 01131-55-361909 SERIES E Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissions. Versa also reserves the right to change or delete data or products at any time without prior notification. To be sure the data you require is correct, consult factory. FULL SIZE Side-Ported Types Series E Full-Size Side-Ported valves are direct solenoid actuated and are individually mounted. 1/8 NPT or 1/4 NPT ports are provided in the valve body. TECHNICAL DATA Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult factory for clarification. Seals: Ordinary Location Valves—NBR (Nitrile) is standard; other sealing materials are available for compatibility with various oils, acidic fluids & gases, etc. See Options on page 14 or consult factory. Hazardous Location Valves—FKM (fluorocarbon) per ASTM D1418/ISO-1629. Construction: Stainless steel (302, 304 & 430F) wetted parts. Coil cover is zinc chromate coated steel. Electrical: Class F epoxy molded coils rated for continuous duty; 9.5-12 watt DC, 7.3-10 watt AC nominal power. See page 17 for coil voltages. Ordinary Location Solenoids are CSA certified; NEMA 1, 2 & 3; NEMA 4/IP65. Hazardous Location Solenoids are UL listed and CSA certified; NEMA 7 & 9. Solenoids approved by ATEX are also available. See pages 16 & 18. Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges. Flow: See page 19. Options: See pages 14 thru 16. ORDINARY LOCATIONS (NEMA 1, 2, 3) PORTED ADAPTER-SPECIFY -H FOR 1/4ⴖ NPT -H2 FOR 1/8ⴖ NPT 24ⴖ (61 cm) COIL LEADS #18AWG WIRE C HAZARDOUS LOCATIONS (NEMA 7 & 9) PORTED ADAPTER-SPECIFY -H FOR 1/4ⴖ NPT -H2 FOR 1/8ⴖ NPT .75 19 1/2ⴖ NPT. CONDUIT CONNECTION C .75 19 24ⴖ (61 cm) GROUND LEAD (GREEN) 24ⴖ (61 cm) COIL LEADS #18AWG WIRE 1/2ⴖ NPT. CONDUIT CONNECTION 2.82 71.6 OPTIONAL MANUAL OVERRIDE OPTIONAL MANUAL OVERRIDE 3.22 81.8 1.84 46.7 .62 15.7 B .31 7.9 1.88 ø 47.8 2.16 54.9 .34 8.6 1.62 ø 41 .62 15.7 B .31 7.9 1/8 OR 1/4ⴖ NPT. ( 2 PORTS) 1.62 ø 41 .34 8.6 1/8 OR 1/4ⴖ NPT. ( 2 PORTS) DIMENSIONS SHOWN IN INCH MM 2.39 60.7 B 2.59 65.8 B .88 22.4 .44 11.2 A .44 11.2 .88 22.4 A #10 - 32 UNF - 2B x .31 THREAD DEPTH ( 2 MOUNTING HOLES ) #10 - 32 UNF - 2B x .31 THREAD DEPTH ( 2 MOUNTING HOLES ) .44 11.2 .88 22.4 .44 .88 11.2 22.4 Color shows piped port C or normally open valve; metric dimensions. Coil cover shown is supplied as standard and provides housing with threaded boss for conduit connection. Other housing types are available. See Suffix Detail Options on page 14. 2 ORDINARY LOCATIONS (For Coil Voltages See Page 17) Type TWO-WAY 2/2 NORMALLY CLOSED Air, Oil or Water Maximum Operating Pressure Differential1 psi (bar)2 250 (17) 200 (14) 125 (8.6) 100 (6.9) 75-50 (5.2-3.4) 50-25 (3.4-1.7) 20-5 (1.4-0.3) Product Number with conduit type coil housing. For other housing options see page 14. 1/8” NPT ESM-2201-30-(*) ESM-2201-40-(*) ESM-2201-60-(*) ESM-2201-80-(*) ESM-2201-100-(*) ESM-2201-120-(*) ESM-2201-160-(*) 1/4” NPT ESM-2301-30-(*) ESM-2301-40-(*) ESM-2301-60-(*) ESM-2301-80-(*) ESM-2301-100-(*) ESM-2301-120-(*) ESM-2301-160-(*) Min. Orifice between Ports “A”-“B” Piping Arrangement and Flow Pattern “B”-“C” 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 5/32 (4.0 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) B DE-ENERGIZED ENERGIZED A Port B = Inlet Port A = Outlet A B Port B blocked to Port A. TWO-WAY 2/2 NORMALLY OPEN Air, Oil or Water 200 (14) 150 (10) 125 (8.6) ESM-2202-03-H2-(*) ESM-2202-04-H2-(*) ESM-2202-06-H2-(*) ESM-2302-03-H-(*) ESM-2302-04-H-(*) ESM-2302-06-H-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) B DE-ENERGIZED ENERGIZED C C C Port B = Inlet Port C = Outlet B Port B connected to Port C. THREE-WAY 3/2 NORMALLY CLOSED (EXHAUST TO ATMOSPHERE) Air Only 150 (10) 100 (6.9) 75 (5.2) 50 (3.4) 20 (1.4) Vac-AC only ESM-3201-34-(*) ESM-3201-44-(*) ESM-3201-66-(*) ESM-3201-86-(*) ESM-3201-126-(*) ESM-3201-166-(*) ESM-3301-34-(*) ESM-3301-44-(*) ESM-3301-66-(*) ESM-3301-86-(*) ESM-3301-126-(*) ESM-3301-166-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) THREE-WAY 3/2 NORMALLY CLOSED (PIPED EXHAUST) Air, Oil or Water 150 (10) 100 (6.9) 75 (5.2) 50 (3.4) 20 (1.4) Vacuum-AC only ESM-3201-34-H2-(*) ESM-3201-44-H2-(*) ESM-3201-66-H2-(*) ESM-3201-86-H2-(*) ESM-3201-126-H2-(*) ESM-3201-166-H2-(*) ESM-3301-34-H-(*) ESM-3301-44-H-(*) ESM-3301-66-H-(*) ESM-3301-86-H-(*) ESM-3301-126-H-(*) ESM-3301-166-H-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) ESM-3202-43-H2-(*) ESM-3202-44-H2-(*) ESM-3202-84-H2-(*) ESM-3202-66-H2-(*) ESM-3202-86-H2-(*) ESM-3302-43-H-(*) ESM-3302-44-H-(*) ESM-3302-84-H-(*) ESM-3302-66-H-(*) ESM-3302-86-H-(*) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/8” (3.2 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) THREE-WAY 3/2 NORMALLY OPEN Air, Oil or Water 150 (10) 100 (6.9) 100 (6.9) 75 (5.2) 75 (5.2) A C ENERGIZED C ESM-7202-43-H2-(*) ESM-7202-44-H2-(*) ESM-7202-66-H2-(*) ESM-7202-86-H2-(*) ESM-7302-43-H-(*) ESM-7302-44-H-(*) ESM-7302-66-H-(*) ESM-7302-86-H-(*) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) B A 150 (10) 100 (6.9) 75 (5.2) ESM-8202-33-H2-(*) ESM-8202-44-H2-(*) ESM-8202-66-H2-(*) ESM-8302-33-H-(*) ESM-8302-44-H-(*) ESM-8302-66-H-(*) A B Port A blocked to Port B; Port B connected to Port C. DE-ENERGIZED Port A connected to Port B; Port C blocked. A C ENERGIZED C C B Port C = Inlet Port B = Cylinder Port Port A = Exhaust A 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) DE-ENERGIZED A B Port C blocked. Port B connected to Port A. A C ENERGIZED C C B A Port B connected to Port C; Port A blocked. THREE-WAY 3/2 MULTI-PURPOSE Air, Oil or Water C B Port A = Inlet Port B = Cylinder Port Port C = Exhaust B 200 (14) 150 (10) 125 (8.6) 100 (6.9) B Port B blocked to Port C. DE-ENERGIZED Port C connected to Port B; Port A blocked. THREE-WAY 3/2 DIRECTIONAL CONTROL Air, Oil or Water A B Port B connected to Port A. 3/64” (1.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) B Port B = Inlet Port C = Outlet I Port A = Outlet II A B Port B connected to Port A; Port C blocked. A C B DE-ENERGIZED C B A Multi-purpose valves may be used as Three-Way, NC or ThreeWay, NO or Directional Control Valves. Two-Way, NC or Two-Way, NO can be accomplished by plugging the appropriate port. ENERGIZED C B A HAZARDOUS LOCATIONS Add Suffix -XX To Above Product Numbers (See page 16 for other Hazardous Location Solenoids) NOTES: *Specify coil code # from page 17. 1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure in color is for DC. Vacuum is AC only. 2. MPa = bar 10 3 SERIES E FULL SIZE Manifold-Mounting Types Each Series E Full-Size Manifold Mounting valve is direct solenoid actuated and is mounted on a manifold which can have 1 to 10 valve stations. The manifolds are provided with the threaded ports for pipe connections, which allows the valves to be easily and swiftly installed or removed without breaking any pipe connections. The manifolds also provide common ports, such as the inlet and exhaust, making only one such connection necessary per manifold. Installation is neater and maintenance easier since valves are grouped in one location. Several different piping arrangements are available to provide flexibility of application. Valves are supplied assembled to manifolds, but must be ordered separately. Station Blanks (E-189) are available for blocking off any unused or “future” valve stations on the manifold. To order complete unit, specify manifold desired and quantity and valve model number required. Valves must all be the same model. TECHNICAL DATA Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult factory for clarification. Seals: NBR (nitrile) is standard; other sealing materials are available for compatibility with various oils, acidic fluids & gases, etc. See Options on page 14 or consult factory. Construction: Valve bodies and manifolds are aluminum. (Stainless steel valve bodies and manifolds are available. Consult factory.) Wetted solenoid parts are stainless steel (302, 304 & 430F). Coil cover is zinc chromate coated steel. Electrical: Class F epoxy molded coils rated for continuous duty; 9.5-12 watt DC, 7.3-10 watt AC nominal power. See page 17 for coil voltages. Ordinary Location Solenoids are CSA certified: NEMA 1, 2 & 3; NEMA 4/IP65. Hazardous Location Solenoids are UL listed and CSA certified; NEMA 7 & 9. Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges. Flow: See page 19. Options: See pages 14 thru 16. WITHOUT ELECTRICAL PLUG-IN (NEMA 1, 2, 3) WITH ELECTRICAL PLUG-IN (NEMA 1, 2, 3) Typical THREE-WAY Normally Closed Type DIMENSIONS SHOWN IN INCH MM (Piped Exhaust) FEATURES OF MANIFOLD: COMMON INLET FOR ALL VALVES INDIVIDUAL OUTLETS (CYLINDER PORTS) FOR EACH VALVE COMMON EXHAUST PORT FOR ALL VALVES Plug-in type also has common electrical junction box & conduit connection (Types Available Include 2-Way NC, 2-way NO, 3-way NC, 3-Way NO, Directional. Consult factory for information concerning specific product required.) (Exhaust to Atmosphere) FEATURES OF MANIFOLD: COMMON INLET FOR ALL VALVES INDIVIDUAL OUTLETS (CYLINDER PORTS) FOR EACH VALVE Plug-in type also has common electrical junction box & conduit connection 1/2⬙ Standard Conduit Connection 3/4 NPT Electrical Conduit Connection 1.75 44.5 2.0 51 EXHAUST (BOTH ENDS) 1.78 45.2 Typical SEE TABLE FOR VALVE PRODUCT NUMBER 6.56 167 Two Mounting Holes for 1/4⬙ Screws 1/4 NPT Cylinder Ports 1.25 31.8 4 CYL CYL CYL 4.5 114 2.0 51 SINGLE STATION: 1/4 NPT MULTIPLE STATION: 3/8 NPT INLET BOTH ENDS Add 1.78” (45.2 mm) for each additional valve station required. Detail and descriptions in color apply to plug-in type valve and manifold. 1.78 45.2 Typical 6.56 167 Two Mounting Holes for 1/4⬙ Screws 1/4 NPT Cylinder Ports 1.25 31.8 CYL CYL CYL ORDINARY LOCATIONS (For Coil Voltages See Page 17) Product Number Valve Type TWO-WAY 2/2 NORMALLY CLOSED Air, Oil or Water TWO-WAY 2/2 NORMALLY OPEN Air, Oil or Water Maximum Operating Pressure Differential (Note 1) psi (bar) (Note 2) 250 (17) 200 (14) 125 (8.6) 100 (6.9) 75-50 (5.2-3.4) 50-25 (3.4-1.7) 20-5 (1.4-0.3) 200 (14) 150 (10) 125 (8.6) Listed with conduit type coil housing. (Note 3) Manifold Min. Orifice between Valve Ports One Inlet (3/8 NPT) serves all Valves: Individual Outlets (1/4 NPT) (Notes 3 & 4) Individual Inlet (1/4 NPT) and Outlet (1/4 NPT) for Each Valve (Notes 3 & 4) Individual Inlet (1/4 NPT) for Each Valve: One Outlet (3/8 NPT) Serves all (Notes 3 & 4) ESM-2011-30-(*) ESM-2011-40-(*) ESM-2011-60-(*) ESM-2011-80-(*) ESM-2011-100-(*) ESM-2011-120-(*) ESM-2011-160-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 5/32” (4.0 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) EM-21-210-† EM-21-220-† EM-21-120-† ESM-2012-03-Z-(*) ESM-2012-04-Z-(*) ESM-2012-06-Z-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) EM-22-012-† EM-22-022-† — EM-31-210-† “In”“Cyl” “Cyl” “Exh” THREE-WAY 3/2 NORMALLY CLOSED (EXHAUST TO ATMOSPHERE) Air Only 150 (10) 100 (6.9) 75 (5.2) 50 (3.4) 20 (1.4) Vacuum-AC Only ESM-3011-34-(*) ESM-3011-44-(*) ESM-3011-66-(*) ESM-3011-86-(*) ESM-3011-126-(*) ESM-3011-166-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) EM-31-120-† EM-31-220-† THREE-WAY 3/2 NORMALLY CLOSED (COMMON PIPED EXHAUST) Air, Oil or Water 150 (10) 100 (6.9) 75 (5.2) 50 (3.4) 20 (1.4) Vacuum-AC Only ESM-3011-34-Z-(*) ESM-3011-44-Z-(*) ESM-3011-66-Z-(*) ESM-3011-86-Z-(*) ESM-3011-126-Z-(*) ESM-3011-166-Z-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) EM-31-121-† EM-31-221-† 150 (10) 100 (6.9) 100 (6.9) 75 (5.2) 75 (5.2) ESM-3012-43-Z-(*) ESM-3012-44-Z-(*) ESM-3012-84-Z-(*) ESM-3012-66-Z-(*) ESM-3012-86-Z-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/8” (3.2 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) EM-32-121-† THREE-WAY 3/2 NORMALLY OPEN (COMMON PIPED EXHAUST) Air, Oil or Water “In”“Out 1” THREE-WAY 3/2 DIRECTIONAL CONTROL Air, Oil or Water 200 (14) 150 (10) 125 (8.6) 100 (6.9) ESM-7012-43-Z-(*) ESM-7012-44-Z-(*) ESM-7012-66-Z-(*) ESM-7012-86-Z-(*) Add Suffix -XX to Valve Product Numbers Shown Above. See Pages 16 & 18 for Other Options 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) { †Insert Number of Valve Stations Required. Manifolds Are Supplied In 1 to 10 Stations. “In”“Out 2” HAZARDOUS LOCATIONS } EM-72-212-† Change Prefix “EM” to “E7M.” Example: E7M-72-212-†. NOTES: *Specify coil code # from page 17. 1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure in color is for DC. Vacuum is AC only. 2. MPa = bar 10 3. To specify electrical plug-in option add -P to product number shown. Indicator lights mounted in junction box can also be provided when using plug-in valves. Use Suffix -36B for this option. Limitation: 90-250VDC, 70-250VAC/50 or 60 Hz. Plug in option not available with solenoids for hazardous location. 4. All ports of single station manifolds are 1/4 NPT. 5 SERIES E5 COMPACT Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissions. Versa also reserves the right to change or delete data or products at any time without prior notification. To be sure the data you require is correct, consult factory. Side-Ported Types Series E5 compact valves are direct solenoid actuated valves. They are physically smaller than the Series E full-size valves described on pages 2 through 5, but offer most of the same orifice sizes and operating pressure ranges as the larger valves. Ports are 1/8 NPT in the valve body and the valves are individually mounted. TECHNICAL DATA Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult factory for clarification. Seals: Ordinary Location Valves—NBR (Nitrile) is standard; other sealing materials are available for compatibility with various oils, acidic fluids & gases, etc. See Options on page 14 or consult factory. Hazardous Location Valves—FKM (fluorocarbon) per ASTM D1418/ISO-1629. Construction: Stainles steel (302, 304 & 430F) wetted parts. Coil cover is zinc chromate coated steel (available in 182FM stainless steel on Hazardous Location valves). See Options on page 14. Electrical: Class F epoxy molded coils rated for continuous duty; 1.8-10.5 watt DC, 4-8.5 watt AC nominal power. See page 17 for coil voltages. Ordinary Location Solenoids are CSA certified; NEMA 1, 2 & 3; NEMA 4/IP65. Hazardous Location Solenoids are UL listed and CSA certified; NEMA 7 & 9. Solenoids approved by FM & ATEX are also available. See pages 16 & 18. Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges. Flow: See page 19. Options: See pages 14 thru 18. ORDINARY LOCATION VALVE (NEMA 1, 2, 3) 6 HAZARDOUS LOCATION VALVE (NEMA 7 & 9) ORDINARY LOCATION VALVE PIPED EXHAUST 1.3 34 1.3 34 1/2 NPT CONDUIT HOUSING (NEMA 1, 2, 3) 1/2 NPT 3.0 75 2.4 61 1.5 38 1.5 38 0.3 7.5 1.0 25.4 0.3 7.5 0.3 7.5 1.0 25.4 0.2 5.2 0.2 5.2 0.3 7.5 0.3 7.5 0.3 7.5 0.2 5.2 GROMMETED LEADS (NEMA 1, 2, 3) Mounting Holes # 8-32 UNC x 15/64⬙ (5.9) 2 places as shown 0.2 5.2 Two-Way NC Three-Way NC (Exhaust to Atmosphere) Mounting Holes # 8-32 UNC x 15/64⬙ (5.9) Thd. 2 places as shown Three-Way NC (Piped Exhaust) Three-Way NO Two-Way NO Directional Multi-purpose DIN COIL & CONNECTOR (NEMA 4/IP65) DIMENSIONS SHOWN IN INCH MM HAZARDOUS LOCATION VALVE (NEMA 7 & 9) UL Listed or CSA Certified. (See pages 16 & 18 for other Hazardous Location Solenoids) All coils provided with 3rd wire ground 1.5 39 1.5 39 1/8 PTF 1/2 NPT 1/2 NPT 3.3 83 2.5 63 1.6 0.9 42 23 1/8 PTF (2 PLACES) 0.2 0.3 5.2 7.5 1.0 25.4 0.3 7.5 0.9 23 1/8 PTF (2 PLACES) 0.2 5.2 0.3 7.5 0.2 5.2 8-32 UNC 15/64⬙ DEEP 2 places (5.9) DIMENSIONS SHOWN IN INCH MM Two-Way NC Three-Way NC (Exhaust to Atmosphere) 0.3 7.5 1.4 37 1.4 37 0.3 7.5 1.0 25.4 1.6 42 0.3 7.5 0.2 5.2 8-32 UNC 15/64⬙ DEEP 2 places (5.9) Three-Way NC (Piped Exhaust) Three-Way NO Two-Way NO Directional Multi-purpose 7 SERIES E5 COMPACT ORDINARY LOCATIONS (For Coil Voltage See Page 17) Maximum Operating Pressure Differential — psi (bar)†† Type AC DC with 1/2” NPT Conduit Connection with DIN Coil & Connector with Grommeted Leads NC-Comm E5SM-2201-20-(*) E5SM-2201-30-(*) E5SM-2201-40-(*) E5SM-2201-60-(*) E5SM-2201-80-(*) E5SM-2201-20-HC-(*) E5SM-2201-30-HC-(*) E5SM-2201-40-HC-(*) E5SM-2201-60-HC-(*) E5SM-2201-80-HC-(*) E5SM-2201-20-243-(*) E5SM-2201-30-243-(*) E5SM-2201-40-243-(*) E5SM-2201-60-243-(*) E5SM-2201-80-243-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) E5SM-2202-02-H2-(*) E5SM-2202-03-H2-(*) E5SM-2202-04-H2-(*) E5SM-2202-02-HC-H2-(*) E5SM-2202-03-HC-H2-(*) E5SM-2202-04-HC-H2-(*) E5SM-2202-02-H2-243-(*) E5SM-2202-03-H2-243-(*) E5SM-2202-04-H2-243-(*) Comm-NO TWO-WAY 2/2 NORMALLY CLOSED Air, Oil or Water 500 400 200 100 75 TWO-WAY 2/2 NORMALLY OPEN Air, Oil or Water 400 (27) 200 (14) 125 (8.6) 200 (14) 100 (6.9) 60 (4.1) THREE-WAY 3/2 NORMALLY CLOSED (EXHAUST TO ATMOSPHERE) Air Only 200 150 150 100 60 30 (14) (10) (10) (6.9) (4.1) (2.1) 200 150 150 100 60 30 (14) (10) (10) (6.9) (4.1) (2.1) E5SM-3201-22-(*) E5SM-3201-33-(*) E5SM-3201-34-(*) E5SM-3201-44-(*) E5SM-3201-64-(*) E5SM-3201-84-(*) E5SM-3201-22-HC-(*) E5SM-3201-33-HC-(*) E5SM-3201-34-HC-(*) E5SM-3201-44-HC-(*) E5SM-3201-64-HC-(*) E5SM-3201-84-HC-(*) E5SM-3201-22-243-(*) E5SM-3201-33-243-(*) E5SM-3201-34-243-(*) E5SM-3201-44-243-(*) E5SM-3201-64-243-(*) E5SM-3201-84-243-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) THREE-WAY 3/2 NORMALLY CLOSED (PIPED EXHAUST) Air, Oil or Water 200 150 150 100 60 30 (14) (10) (10) (6.9) (4.1) (2.1) 200 150 150 100 60 30 (14) (10) (10) (6.9) (4.1) (2.1) E5SM-3201-22-H2-(*) E5SM-3201-33-H2-(*) E5SM-3201-34-H2-(*) E5SM-3201-44-H2-(*) E5SM-3201-64-H2-(*) E5SM-3201-84-H2-(*) E5SM-3201-22-HC-H2-(*) E5SM-3201-33-HC-H2-(*) E5SM-3201-34-HC-H2-(*) E5SM-3201-44-HC-H2-(*) E5SM-3201-64-HC-H2-(*) E5SM-3201-84-HC-H2-(*) E5SM-3201-22-H2-243-(*) E5SM-3201-33-H2-243-(*) E5SM-3201-34-H2-243-(*) E5SM-3201-44-H2-243-(*) E5SM-3201-64-H2-243-(*) E5SM-3201-84-H2-243-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) THREE-WAY 3/2 NORMALLY OPEN Air, Oil or Water 150 125 100 75 (10) (8.6) (6.9) (5.2) 150 125 75 45 (10) (8.6) (5.2) (3.1) E5SM-3202-22-H2-(*) E5SM-3202-33-H2-(*) E5SM-3202-44-H2-(*) E5SM-3202-64-H2-(*) E5SM-3202-22-HC-H2-(*) E5SM-3202-33-HC-H2-(*) E5SM-3202-44-HC-H2-(*) E5SM-3202-64-HC-H2-(*) E5SM-3202-22-H2-243-(*) E5SM-3202-33-H2-243-(*) E5SM-3202-44-H2-243-(*) E5SM-3202-64-H2-243-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) THREE-WAY 3/2 DIRECTIONAL CONTROL Air, Oil or Water 300 200 100 75 (21) (14) (6.9) (5.2) 200 100 50 25 (14) (6.9) (3.4) (1.7) E5SM-7202-22-H2-(*) E5SM-7202-33-H2-(*) E5SM-7202-44-H2-(*) E5SM-7202-64-H2-(*) E5SM-7202-22-HC-H2-(*) E5SM-7202-33-HC-H2-(*) E5SM-7202-44-HC-H2-(*) E5SM-7202-64-HC-H2-(*) E5SM-7202-22-H2-243-(*) E5SM-7202-33-H2-243-(*) E5SM-7202-44-H2-243-(*) E5SM-7202-64-H2-243-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) THREE-WAY 3/2 MULTIPURPOSE Air, Oil or Water 125 (8.6) 100 (6.9) 65 (4.5) 125 (8.6) 100 (6.9) 50 (3.4) E5SM-8202-22-H2-(*) E5SM-8202-33-H2-(*) E5SM-8202-44-H2-(*) E5SM-8202-22-HC-H2-(*) E5SM-8202-33-HC-H2-(*) E5SM-8202-44-HC-H2-(*) E5SM-8202-22-H2-243-(*) E5SM-8202-33-H2-243-(*) E5SM-8202-44-H2-243-(*) 1/32” (0.8 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 1/16” (1.6 mm) 1/2 NPT Conduit Connection Mini-DIN Connector Grommeted Leads (Flying Leads) (34) (27) (14) (6.9) (5.2) 250 150 100 45 25 NOTES: *Specify coil code # from page 17. † For air only. †† MPa = bar 10 8 Minimum Orifice between Ports Product Number (17) (10) (6.9) (3.1) (1.7) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) HAZARDOUS LOCATION VALVES UL Listed or CSA Certified. (See pages 16 & 18 for other Hazardous Location Solenoids) Low Wattage †For Air Only Standard Wattage NO COM DE-ENERGIZED NO 1.8 Watt Max See Available Voltage Below E5SM-2201-20-XX-(*) E5SM-2201-30-XX-(*) E5SM-2201-40-XX-(*) E5SM-2201-60-XX-(*) E5SM-2201-80-XX-(*) 120 (8.3) 80 (5.5) 50 (3.4) E5SM-2201-20-LB-XX-(*) E5SM-2201-30-LB-XX-(*) E5SM-2201-40-LB-XX-(*) E5SM-2202-02-H2-XX-(*) E5SM-2202-03-H2-XX-(*) E5SM-2202-04-H2-XX-(*) 120 (8.3) 50 (3.4) E5SM-2202-03-H2-LB-XX-(*) E5SM-2202-04-H2-LB-XX-(*) E5SM-3201-22-XX-(*) E5SM-3201-33-XX-(*) E5SM-3201-34-XX-(*) E5SM-3201-44-XX-(*) E5SM-3201-64-XX-(*) E5SM-3201-84-XX-(*) 120 (8.3) 60 (4.1) 30 (2.1) E5SM-3201-23-LB-XX-(*) E5SM-3201-33-LB-XX-(*) E5SM-3201-44-LB-XX-(*) E5SM-3201-22-H2-XX-(*) E5SM-3201-33-H2-XX-(*) E5SM-3201-34-H2-XX-(*) E5SM-3201-44-H2-XX-(*) E5SM-3201-64-H2-XX-(*) E5SM-3201-84-H2-XX-(*) 120 (8.3) 60 (4.1) 30 (2.1) E5SM-3201-23-H2-LB-XX-(*) E5SM-3201-33-H2-LB-XX-(*) E5SM-3201-44-H2-LB-XX-(*) E5SM-3202-22-H2-XX-(*) E5SM-3202-33-H2-XX-(*) E5SM-3202-44-H2-XX-(*) E5SM-3202-64-H2-XX-(*) COM - INLET NO - OUTLET NC - OUTLET E5SM-7202-22-H2-XX-(*) E5SM-7202-33-H2-XX-(*) E5SM-7202-44-H2-XX-(*) E5SM-7202-64-H2-XX-(*) NO NC COM NC COM DE-ENERGIZED ENERGIZED AC or DC N0 - INLET COM - OUTLET NC - EXHAUST NO NC COM NC COM DE-ENERGIZED ENERGIZED NO NC - INLET COM - OUTLET NO - EXHAUST NO NC COM NC COM DE-ENERGIZED ENERGIZED NO COM - INLET NC - OUTLET NO NC COM NC COM DE-ENERGIZED ENERGIZED NO COM - INLET NC - OUTLET NO COM ENERGIZED Product Number† (For Coils Available; See Below) Product Number (For Coils Available See Page 17) Piping Arrangement and Flow Pattern NC COM NC COM DE-ENERGIZED ENERGIZED Maximum Operating Pressure Differential† psi (bar)†† FOR INLET/OUTLET INFORMATION SEE CHART BELOW E5SM-8202-22-H2-XX-(*) E5SM-8202-33-H2-XX-(*) E5SM-8202-44-H2-XX-(*) 1/2 NPT Conduit Connector PORT N.C. N.O. COM. 2-WAY N.O. PLUG OUTLET INLET 2-WAY N.C. OUTLET PLUG INLET 3-WAY N.O. EXHAUST INLET OUTLET 3-WAY N.C. INLET EXHAUST OUTLET AC Voltage 12/60 24/60 48/60 120/60 240/60 Coil Code # A012 A024 A048 A120 A240 DC Voltage 6 12 24 48 120 Coil Code # D006 D012 D024 D048 D120 1/2 NPT Conduit Connector SELECTOR DIVERTER INLET INLET OUTLET OUTLET OUTLET INLET 9 SERIES EZ Versa exercises diligence to assure that information contained in this catalog is correct, but does not accept responsibility for any errors or omissions. Versa also reserves the right to change or delete data or products at any time without prior notification. To be sure the data you require is correct, consult factory. BANTAM Side Ported Types Series EZ Bantam valves are direct solenoid actuated valves and, physically are the smallest of the Series E type valves. Ports are 1/8 NPT in the valve body and are individually mounted. See below for technical data. Multiple Manifold Types Series EZ Bantam Multiple Manifold valves are direct solenoid actuated and have 2 to 10 valve cavities within a single body. Each valve within the manifold must be the same and perform the same function. See page 12 for a typical product example. Functional Types Available 2-way, NC or NO . . . . . . . . 3-way, NC . . . . . . . . . . . . 3-way, NO . . . . . . . . . . . . Multipurpose . . . . . . . . . . . . . . . . . . . . . . . Ports Provided . Common inlet, individual outlets . Common inlet, individual outlets, exhaust to atmosphere. Common exhaust is available. . Common inlet & exhaust, individual outlets . Individual “NC,” “COM,” & “NO” ports TECHNICAL DATA FOR SIDE-PORTED AND MULTIPLE MANIFOLD TYPES Application: Air, oil or water, and many other media that are compatible with the specific sealing materials used. Consult factory for clarification. Seals: FKM (fluorocarbon) per ASTM D1418/ISO-1629. Construction: Aluminum body or manifold; stainless steel (302, 304 & 430F) solenoid wetted parts. Electrical: Class F epoxy molded coil rated for continuous duty; 10.5 watt DC, 7-8.5 watt AC nominal power. Mini DIN style connector; NEMA 4/IP65 protection. See Options on page 14. Temperature Range: 0ºF (-18ºC) to 180ºF (82ºC). Consult factory for other temperature ranges. Flow: See page 19. Options: See pages 14 & 15. DIMENSIONS SHOWN IN INCH MM 1.76 44.7 PG-9 CORD GRIP 1/8 NPT ADAPTER 1/2⬙ NPT CONDUIT CONNECTION OPTIONAL 1/8ⴖ NPT ADAPTER N O N O 24ⴖ (61 cm LEADS) 24ⴖ (61 cm LEADS) 2.94 74.6 2.25 57.2 1.09 27.8 PARAMUS, NJ NC OPTION-228L #8-32UNC-2B THD. .875 22.2 .296 7.5 .296 7.5 .56 14.3 1.13 28.6 CL COM OPTION -243 .198 5.0 1/8 NPT PORTS .198 5.0 (STANDARD DIN STYLE COIL & CONNECTOR) 10 PARAMUS, NJ NC COM SIDE PORTED VALVES Type TWO-WAY, 2/2 NORMALLY CLOSED Air, Oil or Water Maxumum Operating Pressure Differential1 psi (bar) 500 (34) 400 (27) 200 (14) 150-100 (10-6.8) 65-45 (4.4-3.1) Product Number with Micromini DIN Style Connector (8mm gap). For Other Options See Page 14 EZ-2120-0-HC-(*) EZ-2130-0-HC-(*) EZ-2140-0-HC-(*) EZ-2160-0-HC-(*) EZ-2180-0-HC-(*) Minimum Orifice Between Ports “NC”-“COM” “COM”-“NO” Piping Arrangement and Flow Pattern COM 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) DE-ENERGIZED ENERGIZED NC COM NC Port COM = Inlet Port NC = Outlet Port COM blocked to Port NC. TWO-WAY, 2/2 NORMALLY OPEN Air, Oil or Water 400 (27) 200 (14) 125 (8.6) 40 (2.7) EZ-2202-H2-HC-(*) EZ-2203-H2-HC-(*) EZ-2204-H2-HC-(*) EZ-2206-H2-HC-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) COM DE-ENERGIZED EZ-3122-1-HC-(*) EZ-3133-1-HC-(*) EZ-3144-1-HC-(*) EZ-3166-1-HC-(*) EZ-3186-1-HC-(*) 200 (14) 150 (10) 100 (6.8) 50 (3.4) 30 (2.1) THREE-WAY 3/2 NORMALLY CLOSED (PIPED EXHAUST) Air, Oil or Water 200 (14) 150 (10) 100 (6.8) 50 (3.4) 30 (2.1) EZ-3122-H2-HC-(*) EZ-3133-H2-HC-(*) EZ-3144-H2-HC-(*) EZ-3166-H2-HC-(*) EZ-3186-H2-HC-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) THREE-WAY, 3/2 NORMALLY OPEN Air, Oil or Water 150 (10) 125 (8.6) 100 (6.8) 50 (3.4) EZ-3222-H2-HC-(*) EZ-3233-H2-HC-(*) EZ-3244-H2-HC-(*) EZ-3266-H2-HC-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) NO Port COM = Inlet Port NO = Outlet 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) MULTIPURPOSE, 3/2 Air, Oil or Water 300-200 (20-14) 200-150 (14-10) 100-75 (6.8-5.2) 75-40 (5.2-2.7) EZ-7222-H2-HC-(*) EZ-7233-H2-HC-(*) EZ-7244-H2-HC-(*) EZ-7266-H2-HC-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 125 (8.6) 100 (6.8) 65-50 (4.4-3.4) 25 (1.7) EZ-8222-H2-HC-(*) EZ-1-HC-(*) EZ-8244-H2-HC-(*) EZ-8266-H2-HC-(*) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) ENERGIZED NO COM Port COM blocked to Port NO NC NO DE-ENERGIZED NO COM NC ENERGIZED COM COM Port NC blocked to Port COM; Port COM connected to Port NO. DE-ENERGIZED NO Port NC = Inlet Port COM = Outlet Port NO = Exhaust NC NO NC Port NC connected to port COM; Port NO blocked. ENERGIZED NO NO COM Port NO = Inlet Port COM = Cylinder Port Port NC = Exhaust COM COM NC Port NO connected to Port COM; Port NC blocked. DIRECTIONAL CONTROL, 3/2 Air, Oil or Water NC NO COM Port COM connected to Port NO THREE-WAY, 3/2 NORMALLY CLOSED (EXHAUST TO ATMOSPHERE) Air Only COM Port COM connected to Port NC. DE-ENERGIZED NC Port NO blocked. Port COM connected to Port NC. NC NO ENERGIZED NO NO COM Port COM = Inlet Port NO = Outlet I Port NC = Outlet II COM NC COM NC Port COM connected to Port NC; Port COM connected to Port NO; Port NO blocked. Port NC blocked. NC NO COM DE-ENERGIZED NO COM NC Multi-purpose valves may be used as Three-Way, NC or ThreeWay, NO or Directional Control Valves. Two-Way, NC or Two-Way, NO can be accomplished by plugging the appropriate port. ENERGIZED NO COM NOTES: 1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure shown in color is for DC. Vacuum is AC only. *Specify coil code # from page 17. NC 11 SERIES EZ BANTAM MULTIPLE MANIFOLD TYPE VALVES (2-10 VALVES) Maximum Product Number with Operating Pressure Micromini DIN Style Connector Differential1 (8 mm gap). For Other Options psi (bar) See page 14 Type TWO-WAY, 2/2 NORMALLY CLOSED with Common Inlet Air, Oil or Water EZM-2130-**-0-HC-(*) EZM-2140-**-0-HC-(*) EZM-2160-**-0-HC-(*) EZM-2180-**-0-HC-(*) 150 (10) 100 (6.8) 60 (4.1) 30 (2.1) TWO-WAY, 2/2 NORMALLY OPEN with Common Inlet Air, Oil or Water 200 (14) 125 (8.6) 40 (2.7) EZM-2203-**-Z-HC-(*) EZM-2204-**-Z-HC-(*) EZM-2206-**-Z-HC-(*) THREE-WAY, 3/2 NORMALLY CLOSED (Exhaust to atmosphere) with Common Inlet Air Only 150 (10) 100 (6.8) 50 (3.4) 30 (2.1) EZM-3133-**-1-HC-(*) EZM-3144-**-1-HC-(*) EZM-3166-**-1-HC-(*) EZM-3186-**-1-HC-(*) THREE-WAY, 3/2 NORMALLY CLOSED (PIPED EXHAUST) with Common Inlet & Common Exhaust Air, Oil or Water 150 (10) 100 (6.8) 50 (3.4) 30 (2.1) THREE-WAY, 3/2 NORMALLY OPEN with Common Inlet & Common Exhaust Air, Oil or Water 125 (8.6) 100 (6.8) 50 (3.4) MULTIPURPOSE, 3/2 with Common “NC” Port (See Also Note @) Air, Oil or Water 100 (6.8) 65-50 (4.4-3.4) 25 (1.7) Minimum Orifice Between Ports “NC”-“COM” “COM”- “NO” Piping Arrangement “NC” port = Common Inlet for all valves “COM” port = Individual Outlet for each valve 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) “NO” port = Common Inlet for all valves “COM” port = Individual Outlet for each valve 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) “NC” port = Common Inlet for all valves “COM” port = Individual Outlet for each valve “NO” port - Individual Exhaust for each valve EZM-3133-**-Z-HC-(*) EZM-3144-**-Z-HC-(*) EZM-3166-**-Z-HC-(*) EZM-3186-**-Z-HC-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 1/8” (3.2 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/32” (2.4 mm) “NC” port = Common Inlet for all valves “COM” port = Individual Outlet for each valve “NO” port - Common Exhaust for all valves EZM-3233-**-Z-HC-(*) EZM-3244-**-Z-HC-(*) EZM-3266-**-Z-HC-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) “NO” port = Common Inlet for all valves “COM” port = Individual Outlet for each valve “NC” port - Common Exhaust for all valves EZM-8233-**-@-HC-(*) EZM-8244-**-@-HC-(*) EZM-8266-**-@-HC-(*) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) The table below lists all the possible valve functions which can be obtained by just changing the connections. Port N.C. N.O. COM 2-Way 2-Way N.O. N.C. 3-Way N.O. 3-Way N.C. Selector Diverter Inlet Plug Inlet Exhaust Inlet Exhaust Inlet Inlet Plug Inlet Outlet Outlet Outlet Outlet Outlet Outlet Outlet Inlet NOTES: 1. Pressures are for both AC or DC coil unless two pressures are shown. In that case, the pressure shown in color is for DC. *Specify coil code # from page 17. **Specify number of valve stations required, 2 thru 10. @ “NO” Port variations available: —1— “NO” valve ports are unpiped and exchange to atmosphere. —H2— Each “NO” valve port is provided with a 1/8” NPT adapter for piping each “NO” port individually. —Z— “NO” ports of all valves are connected to a common “NO” port in the manifold. 3.6 90.5 DIMENSIONS SHOWN IN INCH MM 1.75 44.5 1.0 25.4 .25 6.4 12 3.06 77.8 .196 5 MOUNTING HOLE (2) .375 9.5 1.14 29 N.C. 4.0 102 (3 STATION OVERALL LENGTH.) 1.0 1.0 25.4 25.4 C C C L #1 L #2 L #3 .375 9.5 .25 6.4 N.O. Typical Multiple Manifold (Shows common “NO” port arrangement and micromini DIN style connector) 1/8ⴖ NPT PORTING (Both Ends) 1/8ⴖ NPT PORTING .375 9.5 1 2.8 71.4 .5 12.7 PG-9 CORD GRIP COM COM COM ELECTRIC QUICK EXHAUST VALVES (For Pneumatic Application Only) Functional Description Construction The Electric Quick Exhaust Valve is a three-way, NC, 3/2 valve with extra large exhaust orifice in order to provide extra fast movement of the cylinder rod, or to exhaust systems rapidly. When the solenoid is energized the outlet port is connected to the inlet port and the exhaust port is closed. When the solenoid is de-energized the inlet port is closed and the outlet port is connected to the exhaust port, providing rapid evacuation of the system. Body: 316 stainless steel. (Conforms to NACE standard MR-01-75) Solenoid Operator: 304, 430F & 302 stainless steel (wetted parts) Seals: FKM (fluorocarbon) O ring seals; CR (neoprene) coated nylon flapper. Screws: stainless steel TYPES SERIES E5 SERIES E E5QE EQE BASIC VALVE PRODUCT NUMBER BASIC VALVE PRODUCT NUMBER Function Non-Hazardous Location Solenoids (See SUFFIX OPTIONS below for Hazardous Locations) (See SUFFIX OPTIONS below for Hazardous Locations) E5 Series E Series Operating Pressure PSI (bar) 1/4” NPT Inlet 1/4” Outlet & 3/8” NPT Exhaust 1/4” NPT Inlet 1/2” Outlet & 3/4” NPT Exhaust 1/4” NPT Inlet 1/2” Outlet & 3/4” NPT Exhaust 1/4” Quick Exhaust 5-150 (0.3 -10) 5-100 (0.3 -6.9) E5QE-30304-316-*-** E5QE-30404-316-*-** ----------------------------------- ----------------------------------- .06 (.87) .106 (1.5) 3.3 (48) 3.3 (48) 1/2” Quick Exhaust 5-150 (0.3 -10) 5-100 (0.3 -6.9) ----------------------------------- E5QE-50304-316-*-** E5QE-50404-316-*-** EQE-50304-316-*-** EQE-50406-316-*-** .06 (.87) .106 (1.5) 8.8 (128) 8.8 (128) Basic Size 3-Way, 3/2, Normally Closed **Specify any Suffix Options listed below (description on pages 14, 15 & 16). E5QE SUFFIX OPTIONS Standard, none req. -PC (page 14) Flow Cv (Kv) Inlet Exhaust ** Specify Coil Code from page 17. EQE SUFFIX OPTIONS SOLENOID OPERATOR (Non-Hazardous Locations) ----------------------------------- NEMA 1, 1/2 NPT Conduit Entry NEMA 4, 1/2 NPT Conduit Entry SOLENOID OPERATOR (Hazardous Locations, page 16) -XX -LB-XX -PC-XX -ST-XX UL/CSA, 1/2 NPT Conduit Entry w/ (Low Watt) w/ (Potted Coil) w/ (Stainless Steel Coil Housing) -XN -LB-XN -PC-XN -ST-XN ATEX, M20 x 1.5 Conduit Entry w/ (Low Watt) w/ (Potted Coil) w/ (Stainless Steel Coil Housing) -HC-XISC -HCC-XISC +++FACTORY MUTUAL/CSA Intrinsic Safe, DIN connector w/ Pg9 Cord Grip w/ 1/2 NPT Conduit Entry -HC-XISX6 -HCC-XISX6 +++ATEX, Intrinsic Safe (ia), DIN connector w/ Pg9 Cord Grip w/ 1/2 NPT Conduit Entry +++IMPORTANT NOTE - Consult Factory. All above Intrinsic Safe Operators require respective product number change to: E5QE-30202-316-*-D024 (1/4” NPT Basic Size) or E5QE-50202-316-*-D024 (1/2” NPT Basic Size) Operating Pressure is 5-115 PSI (0.3-7.9 bar) Inlet Flow for each is 0.2 Cv (.32 Kv). ATEX, Flameproof (d), Integral Junction Box w/ M20 x 1.5 Conduit Entry w/ 1/2 NPT Conduit Entry -XDAS -XDAT ATEX, Flameproof (d), Encapsulation (m), Increased Safety (e) Integral Junction Box w/ M20 x 1.5 Conduit Entry w/ 6-12 mm Cable Gland w/ 1/2 NPT Conduit Entry Adapter w/ 9-16 mm Cable Gland -XMAA -XMAE -XMAF -XMAG ATEX, Intrinsic Safe (ib), Integral Junction Box w/ M20 x 1.5 Conduit Entry w/ 6-12 mm Cable Gland w/ 1/2 NPT Conduit Entry Adapter -XIFA -XIFE -XIFF 13 SERIES E TYPE VALVES OPTIONS (Add designation to product number in alpha-numeric order) COILS – see page 17 (Series E Fullsize, Series E5 Compact, Series EZ Bantam) COIL HOUSINGS FOR NONHAZARDOUS SERVICE VALVES: (FOR HAZARDOUS SERVICE VALVES SEE PAGE 16) Suffix Detail -HC DIN type 3 prong coil with quick disconnect. Includes female socket with cord grip. NEMA 4I IP65 protection. Series E fullsize, Electrical Quick Exhaust. -HCC DIN type 3 prong coil with quick disconnect. Includes female socket with 1/2” NPT conduit connection. NEMA 4/IP65 protection. Series E fullsize, E5 compact, EZ bantam, Electrical Quick Exhaust. -228L Coil & 1/2” NPT conduit connection integrally molded in epoxy. 24” (61 cm) lead length. NEMA 4/IP65 protection. Series EZ bantam. -243 Grommeted lead housing. 24” (61 cm) lead length. NEMA 1, 2, 3 protection. Series E fullsize. Electrical Quick Exhaust. Flying leads; 24” (61 cm) length. NEMA 1, 2, 3 protection. Series EZ bantam. SEALS (See also “Solenoid Operators for Special Conditions”, -3.) -HCCL DIN type 3 prong coil with quick disconnect. Includes female socket with 1/2” NPT conduit connection, and indicator light when power is on coil. NEMA 4I IP65 protection. Series E fullsize, E5 compact, EZ bantam, Electrical Quick Exhaust. Suffix Detail -155 -EP -HCL DIN type 3 prong coil with quick disconnect. Includes female socket with cord grip and indicator light when power is on coil. NEMA 4/IP65 protection. Series E fullsize, E5 compact, EZ bantam, Electrical Quick Exhaust. FKM (fluorocarbon) per ASTM D1418/ISO-1629, Equips valve with all seals of fluorocarbon (includes suffix -3). Use suffix only for manifold mounting valve when all fluorocarbon seals are required. Series E fullsize. EPR (ethylene propylene) seals (gray/gray) for use with some synthetic oils. Consult factory. Series E fullsize, E5 compact, Electrical Quick Exhaust. For other seal materials consult factory. MANUAL OVERRIDE (Series E fullsize only) Suffix Detail Suffix -M -PC Potted coil for nonhazardous service; coil epoxy encased within housing. NEMA 4/IP65 protection. Series E fullsize, E5 compact, Electrical Quick Exhaust. For Hazardous service see page 15 “Options For Special Conditions”. Suffix -MAE 14 -G5R Guarded type, holding. Requires screwdriver to operate. -M Guarded type, non-holding. Requires probe to operate. -M5R Unguarded type, holding. Has knurled knob. -MAE Unguarded type. Push to operate. SERIES E OPTIONS TYPE VALVES (Add designation to product number in alpha-numeric order) FLOW Series E fullsize Suffix Detail MOUNTING BRACKETS Series E fullsize (Side-ported valves only)* -A Adjustable Metering Exhaust Adapter, provides metering of exhaust flow on Three-Way NC valves. (See -N for Three-Way NO.) Supplied with 1/16” NPT threaded port for pipe connection. Series E fullsize. Suffix Detail -WE Wall mounting bracket attached to coil housing. Mounting holes on 2-1/8” (54 mm) centers. (Not for Hazardous Service Valves. See -WEX.) Adjustable Metering Inlet Flow (Three-Way NC) Adjustable Metering Outlet Flow (Two-Way NC) Adjustable Exhaust (Three-Way NO) (On side-ported models the adjusting needle is located in the side of the valve body. On manifold mounting models a separate Adapter Plate, E-112-A, is required for mounting between the valve and the manifold. The Adapter Plate contains the adjustable needle. Therefore, the suffix “-N” is not required as part of the valve product number, and the Adapter Plate is specified separately.) Series E fullsize. -WEX Wall mounting bracket attached to valve body. Mounting holes on 2” (51 mm) centers. (Required for Hazardous Service Valves when wall mounting bracket is desired. Cannot be used when valves have suffix detail -N.) -N *All side-ported valves may be line mounted or mounted by using the 10-32 mounting holes in the bottom of the valve body. A Bottom Mounting Bracket, (part no. A-4222-B) with mounting holes on 2” (51 mm) centers can also be supplied, but must be ordered separately. 1.97ⴖ 50 mm 1.13ⴖ 28.7 mm 1.13ⴖ 28.7 mm 1.06ⴖ 26.9 mm 1.06ⴖ 26.9 mm Suffix -WE OPTIONS FOR SPECIAL CONDITIONS Suffix Detail Suffix Detail -HT SOLENOID OPERATOR WITH CLASS H COIL: For UL or CSA approval, consult factory. Recommended for all applications above 150ºF (65ºC) and for DC continuous duty above 120ºF (50ºC). Includes suffix -3. Not for use with suffix -P. Series E fullsize, E5 compact, Electrical Quick Exhaust. -3 -ST Stainless steel (182 FM) coil housing with 1/2” NPT conduit connection. For hazardous service valves only. Series E5 compact, Series E5, Electrical Quick Exhaust. -PS Potted coil for hazardous service valves. Coil and wires sealed at factory. Provides 1/2” NPT conduit connection. Series E fullsize or Series E Electrical Quick Exhaust. For Series E5 compact or Series E5 Electrical Quick Exhaust use -PC. CONTINUOUS DUTY SOLENOID AND/OR HIGH AMBIENT OR MEDIA TEMPERATURE: FKM (Fluorocarbon) seals (TAN/TAN); recommended when coil may be energized for long periods and/or when ambient or media temperature will exceed 120ºF (50ºC). Ordinary Locations: Series E fullsize and Series E Electrical Quick Exhaust, Series E5 compact and Series E5 Electrical Quick Exhaust. Hazardous Locations: option is included. DUST EXCLUDER NUT FOR SOLENOID EXHAUST Non-Hazardous Service Hazardous Service Series E fullsize & Series E Electrical Quick Exhaust -14 -E14 Series E compact & Series E5 Electrical Quick Exhaust -L14 -L14 Series EZ bantam -L14 n/a 15 16 Class I Groups C & D, Area Classification and (Gas Grouping) (ia) Intrinsic Safe Intrinsic Safe (mb) Encapsulation (e) Increased Safety (tD) Tight Dust (d) Flameproof II 2 G EEx ia IIC T4 to T6 II 2 G EEx ia IIC T6 Class I, Groups (A, B, C & D) Class II, Groups (E, F, &G) Class III, Division 1 II 2 G Ex e mb II T5, T6 II 2 D Ex tD A21 T100ºC, T85ºC Ex e mb II T5, T6 Gb Ex tD A21 T100ºC T85ºC Db II 2 G Ex d IIC T4 to T6 ATEX Factory Mutual CSA ATEX IECEx ATEX IECEx ATEX Ex d IIC T4 to T6 Gb IECEx II 2 G Ex d IIB+H2 T3 to T6 UL CSA Certification (Conformance) Ex d IIB+H2 T3 to T6 Gb Class II, Divison 2, Groups E, F & G; T3C; Hazardous Locations Class I, Division 2, Groups A, B, C & D; Protection Classification IP66 & IP67 IP65 IP66 & IP67 IP66 & IP67 IP66 & IP68 NEMA 7 & 9 Ingress Protection 24VDC (0.8W) (Consult factory for other voltages) 24VDC system voltage prior to barrier (1.6 watt max.) 24VDC system voltage prior to barrier (1.6 watt max.) (Consult factory for other voltages) 24VDC (10W inrush, 2.6W holding) 24VDC (4W) (Consult factory for other voltage options) 50 Hz and 60 Hz AC (10W) DC (10W), except 24V50 and 230V50 (6W) 60 Hz AC (1.8W) DC (1.8W) 50 Hz and 60 Hz AC (5.6W) DC (7.2W) 60 Hz AC (1.8W) DC (1.8W) 50 Hz & 60 AC (Series E: 7.3W Series E5: 5.6W) DC (Series E: =9.5W and Series E5:7.2W.) Voltage (Power) Continuous duty. Coil and power controller potted, within housing. Class F epoxy molded coil (155ºC) Continuous duty. Class F epoxy molded coil (155ºC) Continuous duty Continuous duty. Coil & power potted within housing. Continuous duty. Coil & Rectifier, including surge suppression, potted within housing. Class F epoxy molded coil (155ºC) Continuous duty. Class F epoxy molded coil (155ºC) Continuous duty. 3 leads 24” (60 cm). Class F epoxy molded coil (155ºC) Continuous duty. 3 leads 24” (60 cm). Class F epoxy molded coil (155ºC) Continuous duty. 3 leads 24” (60 cm). Class F epoxy molded coil (155ºC) Continuous duty. 3 leads 24” (60 cm) Electrical Characteristics *See page 17 for available Voltages and Coil Code. **Consult factory for pressure rating when using XIF_ coils NOTE: Option -HC-XISC, -HCC-XISC, -HC-XISX6 and -HCC-XISX6 are only available with 3-way NC valves with 1/32” (0.08 mm) orifice, and maximum pressure 115 psi (7.8 bar). -XIFF **(Series E) -XIFE -XIFA (Series E5) See important note below chart -XISX6 (Series E5) See important note below chart -XISC -XMFG (Series E) -XMFF -XMFE -XMFA -XMAG (Series E) -XMAF -XMAE -XMAA -XDAT (Series E) -XDAS (Series E5) -LB-XN (Series E5) -XN (series E) -LB-XX (series E & E5) -XX Suffix Identification HAZARDOUS LOCATION SOLENOIDS Requires the use of an approved safety barrier or isolator. Thick wall epoxy coil housing and integral junction box. Internal ground terminal. M20 x 1.5 conduit entry; (-XIFA) Cable gland for 6-12 mm ø cable: (-XIFE) 1/2 NPT conduit entry with adapter: (-XIFF) Requires the use of an approved barrier or isolator. Maximum operating system voltage before barrier 28VDC. Maximum pilot pressure 115 psi (8 bar) 3 spade terminals & DIN connector with PG9 cable gland; (-HC) 1/2 NPT conduit entry: (-HCC) Requires the use of an approved barrier or isolator. Maximum operating system voltage before barrier 28VDC. Maximum pilot pressure 115 psi (8 bar) 3 spade terminals & DIN connector with PG9 cable gland; (-HC) 1/2 NPT conduit entry: (-HCC) Thick wall epoxy coil housing with integral junction box. Internal ground terminal. M20 x 1.5 conduit entry: (-XMFA) Cable gland for 6-12 mm ø cable: (-XMFE) 1/2 NPT conduit entry with adapter: (-XMFF) Cable gland for 9-16 mm ø cable: (-XMFG) Thick wall epoxy coil housing with integral junction box. Internal ground terminal. M20 x 1.5 conduit entry: (-XMAA) Cable gland for 6-12 mm ø cable: (-XMAE) 1/2 NPT conduit entry with adapter: (-XMAF) Cable gland for 9-16 mm ø cable: (-XMAG) Stainless Steel coil housing with internal Junction Box. Internal and external ground screw. M20 x 1.5 conduit entry: (-XDAS) 1/2 NPT conduit entry: (-XDAT). Steel Chromate plated coil housing with M20 x 1.5 conduit entry. Ground terminal on cover. For stainless steel (182 FM) cover add: -ST. Maximum pilot pressure 120 psi (8 bar). 1.8W nominal power. Steel Chromate plated coil housing with M20 x 1.5 conduit entry. Ground terminal on cover. For stainless steel (182 FM) cover add: -ST.. Steel Chromate plated coil housing with 1/2 NPT conduit entry. For stainless steel (182 FM) coil housing add: -ST. Maximum pilot pressure 120 psi (8 bar). 1.8W nominal power. Steel Chromate plated coil housing with 1/2 NPT conduit entry. For (182FM) stainless steel cover add: -ST Miscellaneous SOLENOID OPERATORS FOR HAZARDOUS SERVICE SERIES E TYPE COILS CONTINUOUS DUTY COIL VOLTAGES1 SERIES E FULLSIZE & SERIES E Electrical Quick Exhaust Solenoid Operator information Nominal Coil Power AC 2NC = 7.7W 2NO, 3-Way, Directional, Multi-Purpose = 8.7W Ordinary Location 9.5W All coils are Class F epoxy Molded.2 Hazardous Location (Suffix -XX) UL Listed Rated voltge or CSA certified. continuous duty 100% Ordinary Location DIN Style Coil & Connector (Suffix -HC, -HCC, -HCCL, -HCL 7.3W Coil Voltages DC AC DC Voltage Coil Code # Inrush Amp Holding Amp Ohm 24/60 120/60 240/60 480/60 A024 A120 A240 A480 1.30 0.26 0.13 0.07 0.82 0.16 0.08 0.04 5.8 146 593 2365 24/50 110/50 230/50 240/50 E024 F120 E230 E240 1.05 0.23 0.11 0.11 0.67 0.15 0.07 0.07 8.5 193 700 876 120/60 240/60 110/50 220/50 A120 A240 E110 E220 0.20 0.13 0.20 0.13 0.16 0.08 0.16 0.08 205 845 205 845 Voltage Coil Code # Inrush & Holding Amp Ohm 6 12 24 48 125 D006 D012 D024 D048 D125 1.54 0.78 0.38 0.19 0.08 3.9 15.5 63 249 1675 12 24 48 D012 D024 D048 0.86 0.44 0.21 14 55 225 9.5W 2NC = 7.7W 12W 10W SERIES E5 COMPACT & SERIES E5 Electrical Quick Exhaust Solenoid Operator information Ordinary Location AC 6W Hazardous Location (Standard Wattage Suffix -XX & -XN) All coils are UL Listed or CSA Class F epoxy certified. molded.2 Hazardous Location (Low Wattage Suffix -LB-XX & -LB-XN) UL Listed or CSA certified. Nominal Coil Power Rated voltage continuous duty 100%. Ordinary Location DIN Style Coil & Connectors (Suffix -HC, -HCC, -HCCL, -HCL) 2NC = 4W 2NO, 3-Way, Directional, Multi-Purpose = 5.6W 1.8W 8.5W Coil Voltages DC AC DC Voltage Coil Code # Inrush Amp Holding Amp Ohm 24/60 120/60 240/60 480/60 A024 A120 A240 A480 0.63 0.13 0.06 0.03 0.38 0.08 0.04 0.02 19 475 2000 8460 24/50 110/50 220/50 240/50 E024 E110 E220 E240 0.61 0.13 0.07 0.06 0.37 0.08 0.04 0.04 25 475 2030 2714 12/60 24/60 48/60 120/60 240/60 A012 A024 A048 A120 A240 0.58 0.29 0.14 0.06 0.03 0.30 0.15 0.07 0.03 0.02 11 43 175 1085 5050 24/60 120/60 240/60 A024 A120 A240 0.63 0.13 0.06 0.05 0.10 0.05 26 647 2790 110/50 220/50 240/50 E110 E220 E240 0.13 0.06 0.06 0.10 0.05 0.05 647 2790 3058 Voltage 7W 7.2W 1.8W 10.5W Coil Code # Inrush & Holding Amp Ohm 6 12 24 47 125 D006 D012 D024 D047 D125 1.30 0.63 0.32 0.16 0.06 4.6 19 75 295 2030 6 12 24 48 120 D006 D012 D024 D048 D120 10.32 0.16 0.08 0.04 0.02 19 75 312 1337 7815 12 24 48 D012 D024 D048 0.86 0.44 0.22 14 55 222 NOTES 1. Many voltages, other than those listed, are available. Consult factory for delivery and technical information. 2. Class H coils are available for both ordinary and hazardous locations. Consult factory. SERIES EZ BANTAM Solenoid Operator information Nominal Coil Power AC Non-hazardous All coils are Standard (DIN style) Class F NEMA 4 epoxy Molded. Also Suffix: -HCC Rated voltge -HCCL continuous -HCL duty 100% -243 -228L Coil Voltages DC AC DC Voltage Coil Code # Inrush Amp Holding Amp Ohm 24/60 120/60 240/60 A024 A120 A240 0.63 0.13 0.06 0.50 0.10 0.05 26 647 2790 110/50 220/50 240/50 E110 E220 E240 0.13 0.06 0.06 0.10 0.05 0.05 647 2790 3058 Voltage 2NC = 7W 8.5W 10.5W 12 24 48 Coil Code # Inrush & Holding Amp D012 D024 D048 0.87 0.43 0.22 Ohm 14 55 222 17 SERIES E OPTIONS & AVAILABILITY Selector Chart & Option Availability for Series E Type Valves PORT SIZE SERIES E fullsize & SERIES E Electrical Quick Exhaust SERIES E5 compact & SERIES E5 Electrical Quick Exhaust 1/8NPT, 1/4NPT 1/8NPT 1/8NPT 1/4NPT na 1/8NPT NC vacuum to 250 psi (17 bar) vacuum to 500 psi (34 bar) vacuum to 500 psi (34 bar) NO vacuum to 200 psi (14 bar) vacuum to 400 psi (27 bar) vacuum to 400 psi (27 bar) NC vacuum to 150 psi (10 bar) vacuum to 200 psi (14 bar) vacuum to 200 psi (14 bar) NO vacuum to 150 psi (10 bar) vacuum to 150 psi (10 bar) vacuum to 150 psi (10 bar) Directional vacuum to 200 psi (14 bar) vacuum to 300 psi (21 bar) vacuum to 300 psi (21 bar) Multipurpose vacuum to 150 psi (10 bar) vacuum to 125 psi (8.6 bar) vacuum to 125 psi (8.6 bar) .06-.79 (0.9-11.5) .022-.23 (0.3-3.3) .022-.23 (0.3-3.3) stainless steel stainless steel aluminum aluminum na aluminum aluminum na na 7.3-8.7 AC, 9.5 DC 6-10.5 AC, 7 DC 7-8.5 AC, 10.5 DC Sideported Manifold PRESSURE RANGE psi (bar) 2-Way 3-Way FLOW RANGE CV(KV) CONSTRUCTION Body Sideported Manifold MTG Manifold NOMINAL POWER (watt) ELECTRICAL CONNECTION/ COIL COVER 1/2” NPT Conduit entry std std -228L Grommeted (flying leads) -243 -243 -243 DIN coil & cable gland connector -HC -HC std DIN coil & 1/2” NPT conduit entry -HCC -HCC -HCC DIN coil & 1/2” NPT conduit entry with indicator light -HCCL -HCCL -HCCL DIN coil & cable gland connector with indicator light -HCL -HCL -HCL Ordinary service -PC -PC na Hazardous service -PS -PC na Potted coil SEALS NBR-nitrite (Buna N) std std na FKM (fluorocarbon) -3 (sideported); -155 (manifolded) std (hazardous locations) -3 (ordinary locations); std (hazardous locations) std EPR-ethylene propylene FLOW OPTIONS MANUAL OVERRIDE Adjustable metering exhaust -EP -EP na 3-Way NC -A na na 3-Way NO -N (1/4 NPT only) na na Adjustable metering inlet 3-Way NC -N (1/4 NPT only) na na Adjustable metering outlet 2-Way NC -N (1/4 NPT only) na na Guarded holding -G5R na na -M na na holding -M5R na na push -MAE na na na na nonholding Unguarded MOUNTING BRACKETS (sideported only) Wall mounting -WE (ordinary locations) -WEX (hazardous locations) Base mounting Part #A-4222-B Bracket na na OPTIONS FOR SPECIAL CONDITIONS High ambient temperature and/or Continuously energized coil -3 -3 (ordinary locations) std (hazardous locations) std Class H coil -HT -HT na Silencer/dust excluder for solenoid exhaust -14 -L14 -L14 Std. Wattage -XX -XX na na -LB-XX; (1.8W) na na -XN na na -LB-XN; (1.8W) na na -ST na S O L E N O I D O P E R A T O R S Hazardous location (d) Flameproof H A Z A R D O U S S E R V I C E * Low-Watt Std. Wattage Low Watt UL & CSA approved ATEX approved Stainless steel coil covers for Hazardous service & (d) Flameproof operators above (d) Flameproof F O R (me) Encapsulation (e) Increased Safety Hazardous location (Ia) Intrinsic Safe (ib) Intrinsic Safe *See Page 16 18 SERIES E bantam Standard Wattage ATEX approved -XDAS, -XDAT na na Standard Wattage ATEX approved -XMAA, -XMAF -XMAE, -XMAG na na -XMFA, -XMFF -XMFE, -XMFG na na FM & CSA approved na -HC-XISC -HCC-XISC na ATEX approved na -HC-XISX6 -HCC-XISX6 ATEX approved -XIFA, -XIFE, -XIFF na Standard Wattage na SERIES E TYPE VALVES FLOW DATA 250 200 Series E Fullsize LE T PR ES SU RE – PS 125 100 75 50 30 I 75 50 25 3 0 20 20 10 3 1 /64 40 20 10 5 /16 FINAL PRESSURE – PSI 60 40 30 10 2 60 40 20 5 80 50 15 4 100 80 60 20 10 6 150 1 /32 PRESSURE DROP – PSI IN 8 70 40 25 15 225 200 175 150 125 100 1 / 16 3/ 32 1/ 8 5/ 323/ 16 1/ 4 ORIFICE – INCH 100 30 10 250 25 250 225 200 175 3 / 64 AIR FLOW IN CFM AT 70º F 5 /8 3 /32 50 10 5 1 /16 /4 ORIFICE – INCH 1 0.1 0.2 0.5 1 2 5 10 20 WATER FLOW – G.P.M. Series E5 Compact AIR FLOW RATE IN CFM AT 70º F 6 400 5 12 T PR ES SU 15 RE – PS I 250 200 150 100 4 50 /32 20 10 5 3 /64 1 /16 3 1 /32 /8 3 / 32 1 /8 ORIFICE – INCH 50 10 5 ORIFICE – INCH 1 0.1 0.2 0.5 1 2 5 WATER FLOW – G.P.M. AIR FLOW RATE IN CFM AT 70º F 6 400 350 IN T PR 250 ES SU 200 RE – PS 200 12 4 10 150 100 8 3 6 150 I 250 14 5 300 LE 300 30 2 1 Series EZ Bantam 350 20 10 5 1 0 40 15 2 FINAL PRESSURE – PSI 400 10 6 150 25 / 16 / 64 100 8 3 200 1 3 / 32 50 PRESSURE DROP – PSI LE 300 1 35 20 10 4 250 50 350 400 60 30 300 100 400 40 40 35 20 30 25 15 20 10 15 2 100 50 50 25 4 1 0 FINAL PRESSURE – PSI 2 /32 3/64 1 5 1 /16 ORIFICE – INCH Flow Factors for various orifice sizes 400 10 5 1 / 32 3 /32 1 3 / 16 / 64 3 / 32 ORIFICE – INCH 100 PRESSURE DROP – PSI IN 350 25 14 50 10 5 Orifice 1/32” (0.8 mm) 3/64” (1.2 mm) 1/16” (1.6 mm) 3/32” (2.4 mm) Cv .022 .06 .106 .21 Kv .32 .87 1.5 3.1 Orifice 1/8” (3.2 mm) 5/32” (4.0 mm) 3/16” (4.8 mm) 1/4” (6.4 mm) Cv .26 .45 .56 .79 Kv 3.8 6.5 8.1 11.5 1 0.1 0.2 0.5 1 2 5 WATER FLOW – G.P.M. 19 IF YOU HAVEN’T FOUND THE VALVE YOU NEED, YOU HAVEN’T ASKED US. Versa Valves… designed, built, and tested to meet your air requirements. SERIES “B” VALVES: 1/8” NPT, 3/16” (4.7mm) Orifice. Two- & Three-Way. Brass & SS Construction. Manual, Pilot & Cam Actuation. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin B. SERIES “B-316”, “B-900” & “B-550” AUTOMATION AND CONTROL VALVES & COMPONENTS FOR PROCESS CONTROL: Suitable for Offshore, Process Control, Material Specs Meet NACE MR-01-75. Fluorocarbon Seals, 1/4” NPT, 3/16” (5mm) Orifice. Three-Way. Solenoid/Pilot, Remote Pilot, Mechanical, Manual & Many Special Actuators. Main Supply Reset Valves; First Out Indicating Valves. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin B316 SERIES “C” VALVES: Fluorocarbon Seals. Solenoid/Pilot, Remote Pilot, Cam & Manual Actuation. Pneumatic Service Vacuum to 175 psi (12 bar). Bulletin K. SERIES “H” VALVES: High pressure hydraulic valves: High pressure valves for the Oil & Gas Industry; to 10,000 psi operating pressure, 316 stainless steel construction, leakproof, balanced dynamic ceramic sealing, O ring static seals, modular design, manifold mounting. Bulletin H SERIES “V” & “T” VALVES: 1/8” thru 1-1/4” NPT or G, Full Ported, Two-, Three-, Four- & FiveWay, Selector, Diverter. All types of Actuation. Forged Brass Construction. Pneumatic Service Vacuum to 200 psi (14 bar), Hydraulic Service to 500 psi (35 bar). Bulletin VT. 10-32 (M5), 1/8” NPT OR G1/8”, 1/4” NPT OR G1/4, 0.6 to 7mm Orifice. Three- & Four-Way, Multi-purpose. Individual Mount, Stacking, or Manifold Mounted. Aluminum, SS & Nylon Construction. Solenoid/Pilot, Pilot, Manual & Mechanical Actuation. Pneumatic Service Vacuum to 115 psi (8 bar). Bulletin C. SERIES “V-316” STAINLESS STEEL VALVES: SERIES “E” VALVES: SOLENOID VALVES FOR THE PROCESS CONTROL INDUSTRY: 1/8” NPT & 1/4” NPT. 1/32” (0.8mm) thru 1/4” (6.4mm) Orifice. Two& Three-Way, Directional, Multi-Purpose. Sideported, and Manifold Mounted. SS or Aluminum Construction. Direct Solenoid Actuation, including LOW WATT. Pneumatic & Hydraulic Service Vacuum to 500psi (35 bar). Bulletin E. Suitable for Offshore, Process Control, Material Spec Meet NACE MR-01-75. Fluorocarbon Seals. 1/4”, 3/8”, 1/2” NPT, Full Ported. Two-, Three-, Four- & Five-Way. Selector. Diverter. All Type of Actuation. Pneumatic Service Vacuum to 200 psi (14 bar). Bulletin V316. Complete Range of Stainless Steel, Brass or Aluminum Constructed Valves, 1/8” NPT through 1 NPT. Direct NAMUR Mount & Bodyported Styles. Latching Manual Reset, Lockout Valves, Redundant Valves. Bulletin PCg. ACCESSORIES: SERIES “K” VALVES: Compact Air Management System. ¼” NPT or G1/4”, 4.7mm & 6.5mm Orifice. Two-, Three-, Four- & Five-Way, Selector, Diverter. Manifold Mounted, Integrated Circuitry, Aluminum Construction. Shuttle Valves, Bleed Control Valves, Dust Excluders, Foot Guards, Bleed Valves, Quick Exhaust Valves, Status Indicators. Bulletin ACC. WARNINGS REGARDING THE DESIGN APPLICATION, INSTALLATION AND SERVICE OF VERSA PRODUCTS The warnings below must be read and reviewed before designing a system utilizing, installing, servicing, or removing a Versa product. Improper use, installation or servicing of a Versa product could create a hazard to personnel and property. DESIGN APPLICATION WARNINGS Versa products are intended for use where compressed air or industrial hydraulic fluids are present. For use with media other than specified or for non-industrial applications or other applications not within published specifications, consult Versa. Versa products are not inherently dangerous. They are only a component of a larger system. The system in which a Versa product is used must include adequate safeguards to prevent injury or damage in the event of system or product failure, whether this failure be of switches, regulators, cylinders, valves or any other system component. System designers must provide adequate warnings for each system in which a Versa product is utilized. These warnings, including those set forth herein, should be provided by the designer to those who will come in contact with the system. Where questions exist regarding the applicability of a Versa product to a given use, inquiries should be addressed directly to the manufacturer. Confirmation should be obtained directly from the manufacturer regarding any questioned application prior to proceeding. INSTALLATION, OPERATION AND SERVICE WARNINGS Do not install or service any Versa product on a system or machine without first depressurizing the system and turning off any air, fluid, or electricity to the system or machine. All applicable electrical, mechanical, and safety codes, as well as applicable governmental regulations and laws must be complied with when installing or servicing a Versa product. Versa products should only be installed or serviced by qualified, knowledgeable personnel who understand how these specific products are to be installed and operated. The individual must be familiar with the particular specifications, including specifications for temperature, pressure, lubrication, environment and filtration for the Versa product which is being installed or serviced. Specifications may be obtained upon request directly from Versa. If damages should occur to a Versa product, do not operate the system containing the Versa product. Consult Versa for technical information. LIMITED WARRANTY DISCLAIMER AND LIMITATION OF REMEDIES Products sold by Versa are warranted to be free from defective material and workmanship for a period of ten years from the date of manufacture, provided said items are used in accordance with Versa specifications. Versa’s liability pursuant to that warranty is limited to the replacement of the Versa product proved to be defective provided the allegedly defective product is returned to Versa or its authorized distributor. Versa provides no other warranties, expressed or implied, except as stated above. There are no implied warranties of merchantability or fitness for a particular purpose. Versa’s liability for breach of warranty as herein stated is the only and exclusive remedy and in no event shall Versa be responsible or liable for incidental or consequential damages. Versa Products Company, Inc., 22 Spring Valley Road, Paramus, New Jersey, USA 07652 • 201/843-2400 FAX: 201/843-2931 Versa BV., Prins Willem Alexanderlaan 1429, 7312 GB Apeldoorn, The Netherlands • 01131-55-3681900 FAX: 01131-55-3681909 www.versa-valves.com