Product information Maintenance package USB FBI1210-0 TCS TürControlSysteme AG, TCS Hotline Germany: FAX: +49 (0) 41 94/ 9 88 129 Mail: info@tcs-germany.de Subject to technical changes PI_FBI1210_uk 1A mi 2 02/2013 Scope of delivery 1x 1x 1x 1x 1x 1x 1x 1x PC Service interface FBI1210 CD: TCS Software EEPROM adapter Connector board (FBI1210) USB cable for PC, 1 m Cable assembly, 4-wires Patch cord RJ45 CAT.5e FTP (8-pin, 2 m) Handset ISH3030 Product information Safety instructions Attention! Mounting, installation, commissioning and repair of electronic devices have ! to be carried out only by qualified electricians. The standards and instructions for the installations of systems must be observed. The device is only suitable for a connection to a USB port at a PC. The housing may only be opened at the manufacturer’s site. Additions or modifications to the device are not allowed and void the warranty Device overview USB jack for PC I2C-jack for EEPROM board RJ11 jack for handset RJ45 jack for TCS:BUS status LED TCS TürControlSysteme AG, TCS Hotline Germany: FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 02/2013 3 Display and operating elements Description Function LED Status indication for operation and serial communication OFF: out of operation ON: in operation Flash OFF: FBI1210 sends / receives UART protocols at/from PC Intended use The maintenance package USB FBI1210-0 is suitable for configuration, monitoring and maintenance of TCS systems. The enclosed interface connects a PC (Laptop) with a TCS system. It should be used indoors. For a short period, it can also be used outdoors, if protected against rain (temperature 0 to 40 °C). The maintenance package USB is only licensed for the use with full versions of con- ! figurators. The user software on the TCS-CD is only for informational and testing purposes. Short description Consists of maintenance interface and TCS-CD TCS-CD encloses: a) driver for maintenance interface, b) limited full version for user software, that requires a license key subject to charge (PCitACC and call central), c) full version of configurators: – configuartion software configo™ – ADx configurator – PFS configurator – maintenance programme Status indication for operation and serial communication standard USB connection galvanic isolation between TCS system and PC error detection and optical indication of overloads und under-voltage at input: – under-voltage at a: below 18 V – overload at a: as of 24,5 V – under-voltage at P: below 15 V – overload at P: as of 28 V – detection of “short-circuit“ and “not supplied“ at M and at V1 and V2 TCS TürControlSysteme AG, TCS Hotline Germany: FAX:+49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 4 02/2013 I2C-Buchse für EEPROM-Platine von PES, PUK, PAK, TCU1, TCU2, AD3; ASI11000-EEPROM über Adapter anschließbar (im Lieferumfang) (EEPROMs von AD1, AD2 können nicht angeschlossen werden) Hörer für Sprechverbindung mit Innen- oder Außenstationen oder für Durchsagen in GFA-Anlagen Commissioning System requirements PC USB-Host-Interface, USB1.2 or USB2.0 standard Operating systems: Windows XP (as of SP2), Vista and Windows 7, Linux (Kernel with CDC Interface) Connection diagram Patchkabel RJ45 Western jack not part of the delivery Patch cord RJ45 Assignment of connectors see table p. 5 TCS TürControlSysteme AG, TCS Hotline Germany: FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 02/2013 5 Possible connections For frequent configuration works, the interface can be connected via a Western socket or an adapter board with the system (Patch cord RJ45 CAT.5e FTP, 2.0 m). V1, V2 and P are only connected to the FBI1210 for monitoring purposes. Connection assignment RJ45 jack, connector board Pin Function 1 - 2 a 3 b 4 - Description Not used Polartity-free 2-wire connection for protocol transfer Polartity-free 2-wire connection for protocol transfer Not used Pin Function 5 P Voltage supply +15 … 28 V DC 6 M Video ground 7 V1 Differential video input 8 V2 Differential video input Description The connector board also features two 4-pin jacks for connecting a bell button extension as well as a 6-pin screw terminal to connect a cable provided by customer. EEPROM connection Via the I2C interface, the following memories can be read-out or written to without a TCS:BUS must be connected: EEPROM board (A) of PES, PUK, PAK, TCU1, TCU2 ASI11000-EEPROM (B) can be connected via adapter (enclosed in the delivery) SPI-EEPROMs (AD1 and AD2) cannot be connected. Put the EEPROM board into the I2C jack A: on the underside there are the structural elements B: on the upper side of the board conducting paths and structural elements of the ASI-EEPROM. Note: This pin header is coated and does not allow a staggered plugging of the EEPROM board. If the pin header is accidentally turned by 180°, neither the EEPROM nor the FBI1210 will be damaged. A B Handset connection If a handset is connected to the device, by using suitable software e.g. TCS:BUS monitor, voice connections from the FBI1210 to indoor and front-door stations can be established. In GFA systems, announcements can be made to suitable indoor stations. For this, connect the handset to the RJ11 jack. TCS TürControlSysteme AG, TCS Hotline Germany: FAX:+49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 6 02/2013 Important notes The device supports the operating systems Windows XP (as of SP2), Vista and Windows7, Linux (Kernel with CDC Interface) and MacOS X. To operate the FBI1210, a system driver is absolutely necessary. If no driver has been installed, the interface does not work. Even if the respective TCS software has been installed on the PC. The USB interface is supported as of operating system Windows 98 SE. Older Windows versions (e.g. Win95 or Win98) are not suitable for the FBI1210. The FBI1210 can be operated with USB1.1 and USB2.0 interfaces. The USB cable must not be longer than 2 m. When connecting the FBI1200 for the first time, it may only be connected when the ! PC is already booted. Installing the driver 1. Start Windows on your PC. 3. Download the latest driver for the virtual COM interface. (on our homepage www.tcsag.de > downloads > software > driver for FBI1200: http://www.tcsag.de/wDeutsch/pages/downloads/Software_Treiber.php) 2. Start the setup file. The driver and the virtual COM interface are installed. Please wait until Console (ill.) is closed again. 3. Connect the FBI1210 using the USB cable to the USB interface of your PC according to the connection diagram (see p. 2). 6. Connect the FBI1210 to the TCS:BUS using the BUS connection cable (see p. 4). TCS TürControlSysteme AG, TCS Hotline Germany: FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 02/2013 7 Technical data supply voltage: housing: dimension FBI1210 (in mm): weight acceptable ambient temperature: input current, standby: max. input current: via USB connection from PC plastics H 42 x W 90 x D 25 45 g 0 °C to 40 °C I(a) = 0.4 mA, I(P) = 2.0 mA I(Pmax) = 2.0 mA FAQ Error pattern The FBI1210 is not recognised at the PC. Possible cause The virtual COM-port-driver to the FBI1200 cannot manage all Bluetooth communication connections. Our solution 1. Open Windows control panel, System, tab Hardware, open device manager. 2. Open connections, right mouse click on Bluetooth communication connection (COMx), deactivate. Conformity Conformity declaration can be downloaded from www.tcsag.de, downloads, trade information. Waste disposal The adjoining symbol shows, that the device has to be disposed separately from domestic waste. The used materials are recyclable. Please do help protecting our environment and dispose the device via a colection point for electronic scrap. Dispose the parts of the packaging in collecting tanks for cardboard and paper resp. plastics. TCS TürControlSysteme AG, TCS Hotline Germany: FAX:+49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi 8 02/2013 Warranty We offer a simplified processing in case of warranty for electricians. Note our conditions of sale and delivery, download from www.tcsag.de, downloads, trade information and included in our latest price list. Please contact us: hotline@tcsag.de Service Please send your questions and inquiries to hotline@tcsag.de Headquarters TCS TürControlSysteme AG, Geschwister-Scholl-Str. 7, 39307 Genthin Tel.:+49 3933/879910, FAX: +49 3933/879911, Mail: info@ tcs-germany.de, www.tcsag.de TCS TürControlSysteme AG, TCS Hotline Germany: FAX: +49 (0) 41 94/ 9 88 129 Mail: hotline@tcsag.de Subject to technical changes. PI_FBI1210_uk 1A mi