SPECIFICATIONS D03 Pattern Directional Control Valves Also refer to "Directional Valve Features, Selection and Operating Recommendations" (dynexdcvoperating.pdf) CONTACT INFORMATION USA Headquarters Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI 53072 U.S.A. Tel: 262-691-2222 FAX: 262-691-0312 E-mail: sales@dynexhydraulics.com Power Units & Systems Dynex/Rivett Inc. 54 Nickerson Road Ashland, MA 01721 U.S.A. Tel: 508-881-5110 FAX: 508-881-6849 E-mail: ashland@dynexhydraulics.com European Sales Dynex/Rivett Inc. Unit C5 Steel Close, Little End Road, Eaton Socon, Huntingdon, Cambs. PE19 8TT United Kingdom Tel: +44 (0) 1480 213980 FAX: +44 (0) 1480 405662 E-mail: sales@dynexhydraulics.co.uk For more information visit our web site: www.dynexhydraulics.com BROCHURE NOTES: Consult the Dynex sales department for a review of any application which requires operating above the rated flows or pressures, or higher than normal operating temperatures. Specifications shown were in effect when published. Since errors or omissions are possible, contact your sales representative for the most current specifications before ordering. Dynex reserves the right to discontinue or change designs at any time without incurring any obligation. DYNEX High Pressure Hydraulics Copyright © Dynex/Rivett Inc. Bulletin dynexvesd03specs-1101 D03 PATTERN Compact Valves Control Flow to 15 U.S. gpm (57 L/min) High performance D03 valves are rated for 8 U.S. gpm (30 L/min) nominal and 15 U.S. gpm (57 L/min) maximum flow, at pressures to 5000 psi (350 bar). This high pressure and high flow capability provides great efficiency in a very compact size. HIGH EFFICIENCY OPERATION 6500 Series Explosion Proof Large internal flow passages, with uniform flow areas throughout the body coring, provide exceptional efficiency. Typical loop pressure drop (open center spool) is a low 98 psi at 8 U.S. gpm (7 bar at 30 L/min) nominal flow (∆P loop = P→A + B →T). 6500 Series Double Solenoid 6800 Series Hydraulic Piloted 6900 Series Air Piloted SMOOTH, RELIABLE SHIFTING A four-land spool design assures exceptionally smooth spool travel. Additional outboard lands provide greater support, eliminating spool imbalance. Balancing grooves provide precise centering, reducing silt buildup and potential spool sticking. HIGH PRESSURE TANK PORT RELIABLE VALVE SEALING High pressure tank port capability provides the highest “T” port rating available. This option (“HPT”) is ideal for higher pressure “series” circuits. Tapered o-ring counterbores reduce leakage, by assuring seal retention in high flow or rapid cycling operation. High-torque mounting prevents weepage between sections when using sandwich accessory valves. 2000 3000 DC 1000 AC 4000 0 Close tolerances assure accurate land sequencing and low leakage. Spools are interchangeable to meet changing requirements. LOW POWER REQUIREMENTS On solenoid models, efficient low power requirements reduce energy consumption. 5000 PSI VALVE BODY PRESSURE PORT MOUNTING SURFACE O-RING HIGH PRESSURE SOLENOID TUBES High pressure solenoid tubes (HPT option) make the D03 ideal for use in higher pressure “series” circuits. Holding power requirements are only 20 Watts for 115 Volt A.C. or 28 Watts for 12 or 24 Volt D.C. solenoids. 2 Potential leakage is reduced by tapered o-ring counterbores which assure seal retention in high flow applications. D03 PATTERN SPECIFICATIONS General For a description of spools,operator functions, electrical options and operating recommendations, refer to dynexdcvoperating.pdf. Mounting Subplate, N.F.P.A. D03 (CETOP 3) pattern Operator Options 6100 Series:Manual Lever; 6500 Series: Direct Solenoid; 6800 Series: Hydraulic Piloted; 6900 Series: Air Piloted Rated Flow Nominal: 8 U.S. gpm (30 L/min); Maximum: 15 U.S. gpm (57 L/min) Maximum flow for models using a Type 011 spool is 9 U.S. gpm (34 L/min) for solenoid models and 10 U.S. gpm (38 L/min) for air and hydraulic pilot operated model. See flow capacity curves on page 4. ELECTRICAL DATA Solenoid Code➀ Input Voltage (Volts) Frequency (Hz) Inrush Current (Amps) Holding Current (Amps) Holding Power (Watts) Coil Resistance (Ohms ± 10%) 24/DF (Dual Frequency) 24 A.C. 24 A.C. 50 60 9.50 8.60 2.60 1.75 27 22 1.67 1.67 115/DF (Dual Frequency) 110 A.C. 115 A.C. 50 60 1.65 1.55 .47 .40 20 20 40.00 44.00 230/DF (Dual Frequency) 220 A.C. 230 A.C. 50 60 .86 .80 .22 .18 20 20 150.00 150.00 460/DF (Dual Frequency) 440 A.C. 460 A.C. 50 60 .40 .41 .13 .10 23 21 600.00 600.00 12 VDC 12 D.C. — — — 28 5.10 24 VDC 24 D.C. — — — 28 20.60 12VDC EPW 12 D.C. — — — 33 4.36 24VDC EPW 24 D.C. — — — 33 17.50 110/50 EPW 110 A.C. 50 1.86 .54 23 35.20 115/60 EPW 115 A.C. 60 1.90 .50 23 33.50 ➀ Ordering Codes shown are for standard wire leads with wiring box. “Plug-In-Terminal” solenoids (Hirschmann GDM 209) are also available; see “Typical Model Code” on page 17. Rated Pressure 5000 psi (350 bar) Tank Port Pressure (Maximum) Standard: 1500 psi (105 bar); High Pressure Option (“HPT”): A.C., 2300 psi (160 bar); D.C., 3000 psi (210 bar) Response Time (Full Stroke) Solenoid Energized: A.C., 12 ms; D.C., 20 ms Spring Returned: A.C., 15 ms; D.C., 20 ms Solenoids Models are available with A.C. or D.C. solenoids. Electrical Connections Standard Wiring Box with leads; Optional Terminal Strip, Cable Grip or Pin Connector (N.F.P.A. standard T3.5-29-1980; A.N.S.I. standard B93,55M-1981); Optional Plug-In-Terminal Solenoids fit DIN Connector Standard 4365 (Hirschmann GDM 209) Explosion Proof Option (“EPW”) Solenoids with special enclosures are approved by UL and CSA for use in hazardous locations. Available with A.C. or D.C. solenoids. UL Classification: Class I, Group C,D; Class II, Group E,F,G CSA/UL Recognized (“C” Option) Solenoid coils are printed with the symbol: C ® (CSA and UL Recognized) Available with 115/DF coils only. For other voltages, contact the Dynex sales department. The table above shows electrical specifications for these valves. MANUAL OPERATED MODELS A12 or B12 Lever operated models offer handle position flexibility with four positions on either port “A” end or port “B” end of valve. A9 or B9 A3 or B3 In-the-field changes are easy, by removing the bracket assembly and rotating the handle to the desired position. A6 or B6 To specify position, see “Typical Model Code” on page 8 and refer to the drawing at right. Handle Position Viewed from Port “A” or Port “B” End of Valve 3 D03 PATTERN Typical Valve Performance FLOW CAPACITY The flow capacity curves show typical performance for each spool type. The letters in the “Flow Curve Reference” table identify the appropriate curve. PRESSURE SOLENOID MODELS BAR PSI 350 5000 300 250 A BC 4000 200 3000 150 2000 J H DE F K G 100 50 LEVER OPERATED MODELS 0 PILOT OPERATED MODELS The maximum flow for pilot operated models is dependent on pilot pressure. Generally, the maximum flow for most pilot operated models is 15 U.S. gpm (57 L/min). When using a Type 011 spool (tandem center, open crossover), the maximum flow rating is 10 U.S. gpm (38 L/min). Minimum Pilot Pressure The table shows the minimum pressure required to shift the spool, for various flow capacities. These values are based on zero tank pressure. As back pressure increases above zero, the minimum pilot pressure must be increased equally. Maximum Pilot Pressure Hydraulic Piloted, 3000 psi (210 bar); Air Piloted, 200 psi (14 bar) Volume Maximum required to shift spool full stroke: Hydraulic, 0.014 in3 (0,23 cm3); Air, 0.220 in3 (3,61 cm3) 2 U.S. GPM Most manual models are rated for 15 U.S. gpm (57 L/min) maximum. The exception is model 613011-D03 which is rated for 13 U.S. gpm (49 L/min) maximum. This model has a Code 3 internal operator (two position, detented operation) with Type 011 spool (tandem center). 1000 4 6 10 L/MIN. 8 20 10 30 12 40 14 16 50 60 FLOW FLOW CURVE REFERENCE Spool Type Solenoid Type 0 A.C. 4 03 1 3 A A H A C E E J J B B D.C. and “EPW” A A A A D K K F F G A 011 2 2R 32 36 32R MINIMUM PILOT PRESSURE Pilot Pressure At: Series Spool Type psi bar psi bar psi bar 6800 Series Hydraulic Piloted 0 1 3 4 011 2 or 2R 32 or 32R 36 03 130 150 145 130 190 190 150 150 130 9,0 10,3 10,0 9,0 13,1 13,1 10,3 10,3 9,0 165 165 165 165 275 275 200 200 165 11,4 11,4 11,4 11,4 19,0 19,0 13,8 13,8 11,4 200 420 180 200 — — — 350 200 13,8 29,0 12,4 13,8 — — — 24,1 13,8 6900 Series Air Piloted 0 1 3 4 011 2 or 2R 32 or 32R 36 03 25 21 25 25 23 23 25 25 25 1,7 1,4 1,7 1,7 1,6 1,6 1,7 1,7 1,7 28 22 28 28 40 40 30 28 28 1,9 1,5 1,9 1,9 2,8 2,8 2,1 1,9 1,9 33 24 34 33 — — — 34 33 2,3 1,7 2,3 2,3 — — — 2,3 2,3 4 5 U.S. gpm (19 L/min) 8 U.S. gpm (30 L/min) 15 U.S. gpm (57 L/min) D03 PATTERN VALVE EFFICIENCY D03 valves provide exceptionally low pressure drop, as shown in the performance curves. PRESSURE DROP (∆P) A BAR The curves show resistance to flow for various spool types. The table identifies the proper pressure drop curve for each spool and flow path. PRESSURE DETERMINING PRESSURE DROP 14 200 E 12 175 10 150 F 8 G 125 100 75 4 2 In the table under spool Type 1, curve “C” is called out to determine the pressure drop for P→A. Looking at the curves, “C” indicates a drop of about 55 psi at 8 U.S. gpm (3,8 bar at 30 L/min). For example, curve “F” is used for the return flow B→T for spool Type 1. Curve “F” indicates a pressure drop of 35 psi at 8 U.S. gpm (2,4 bar at 30 L/min). Adding the individual pressure drops results in a “loop” drop through the valve in both directions of 55 + 35 = 90 psi (3,8 + 2,4 = 6,2 bar). C D 6 AN EXAMPLE To determine total “loop” drop, the individual pressure drops for P→A and B →T (or P→B and A→T) must be added. 225 16 Large internal flow paths, with tank retur n pressure boost, increase available shifting forces for dependable high flow operation. B PSI 50 25 0 2 U.S. GPM 4 6 10 L/MIN. 8 20 10 30 12 14 40 50 16 60 FLOW FLOW CURVE REFERENCE Flow Path Spool Type 0 1 3 4 011 2 2R 32 32R 36 03 P→A B C B C C C C B B B B P→B B C B C C C C B B B B A→T E F F E C C C E F G — B→T E F F E C C C F E G — P→T — D — — A A A — — — — Installation and Dimensions 2.00 (50,8) GENERAL VALVE MOUNTING The mounting surface drawing shows the minimum flush or raised surface required for the N.F.P.A. D03 (CETOP 3) pattern. Mounting face must be flat within 0.0004 inch/4.0 inches (0,010 mm/102 mm) with a surface finish of 32 microinch(0,80 µm) AA. Port o-rings are included with all valves. Mounting bolts must be ordered separately; 10-24 U.N.C. Threaded x 0.75 inch (19 mm), Grade 8 or better; four required. Recommended mounting torque is 65 lb• in (7,3 N• m) maximum. 1.594 (40,49) .16 (4,1), .16 (4,1) DEEP MINIMUM LOCATING PIN HOLE 1.30 (33,0) .19 (4,8) P 1.70 (43,2) 32 (0,80) B A .20 (5,1) 1.220 (30,99) 1.02 1.250 (25,9) (31,75) .61 (15,5) T .0004/4.0 (0,010/102) .250 (6,35) , 4 PORTS .50 (12,7) .85 (21,6) 1.19 (30,2) .25 (6,4) .030 (0,76) #10-24 U.N.C.–2B THREADED .37 (9,4) DEEP, 4 MOUNTING HOLES Minimum Mounting Surface, N.F.P.A. D03 (CETOP 3) Pattern 5 D03 PATTERN SOLENOID MODEL DIMENSIONS Refer to the basic installation drawing for typical dimensions common to all D03 valves. 5.00 (127,0) SOLENOID B FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; SOLENOID A FOR TYPE 011, 2, 2R SPOOLS 3.73 (94,7) 2.74 (69,6) .38 (9,7) GRIP .25 (6,4) Double Solenoid: A.C., 4.0 lb (1,8 kg); D.C., 5.3 lb (2,4 kg) SOLENOID A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; SOLENOID B FOR TYPE 011, 2, 2R SPOOLS MANUAL ACTUATOR PIN Dimensions are shown for both A.C. and D.C. solenoids; D.C. configuration shown printed in gray. Weight (Mass) Single Solenoid: A.C., 3.4 lb (1,5 kg); D.C., 3.9 lb (1,8 kg) 1/2-14 N.P.T. STANDARD ELECTRIC ENTRY, 1 EACH SIDE #10-24 U.N.C. THREADED x .75 (19,0) LONG MOUNTING BOLTS, 4 REQUIRED; TORQUE: 65 LB • IN ( 7,3 N • M) 1.250 (31,75) .88 (22,4) 1.75 (44,4) 1.88 (47,8) .94 (23,9) .37 (9,4) .13 (3,3) .125 (3,18) LOCATING PIN 1.30 (33,0) 1.59 (40,4) .92 (23,4) 2.51 A.C. (63,8) 3.12 D.C. (79,2) 3.53 (89,7) CLEARANCE TO REMOVE COIL 1.68 A.C. (42,7) 8.54 A.C. SOLENOID (216,9) 9.77 D.C. SOLENOID (248,2) 2.30 D.C. (58,4) 6500 Series, Double Solenoid Models 1/2–14 N.P.T. STANDARD ELECTRIC ENTRY 1 EACH END SOLENOID A FOR TYPE 0, 1, 3, 4 03, 32, 32R, 36 SPOOLS; SOLENOID B FOR TYPE 011, 2, 2R SPOOLS 3.73 (94,7) 6.78 A.C. SOLENOID (172,2) REMOVE PLUG, 3/8 INCH INTERNAL HEX, FOR ACCESS TO THIS END SOLENOID B FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; SOLENOID A FOR TYPE 011, 2, 2R SPOOLS 3.73 (94,7) .31 (7,9) .31 (7,9) 6.78 A.C. SOLENOID (172,2) 7.39 D.C. SOLENOID (187,7) 7.39 D.C. SOLENOID (187,7) 6500 Series, Single Solenoid Models LEADWIRES (4) TYPICAL #18 AWG, APPROXIMATELY 18 (457) LONG EXPLOSION PROOF SOLENOIDS 1/2-14 N.P.T. STANDARD ELECTRIC ENTRY, 360˚ ROTATABLE WITH BOTTOM OUTLET SUBPLATE Solenoids with special enclosures are approved by UL and CSA for use in hazardous locations. Overall length of single solenoid models (not shown) is 8.23 inches (209,9 mm). Note that spacer plate, part number 10591320, is required when valves are mounted on manifolds, side outlet subplates or when used as a pilot valve. Valves can be mounted without removing nameplate. Openings in nameplate provide access to mounting holes in valve body. Weight (Mass) Single Solenoid: 8.3 lb (3,8 kg); Double Solenoid: 14.0 lb (6,4 kg) MANUAL ACTUATOR PIN 2.88 (73.2) 3.72 (94,5) 45˚ 1.69 (42,9) .37 (9,4) 1.250 (31,75) 1.75 (44,4) GROUNDWIRE (2) TYPICAL #18 AWG (GREEN INSULATION) APPROXIMATELY 18 (457) LONG NOTE: KEEP AIR GAP BETWEEN SOLENOID AND VALVE BODY CLEAN SOLENOID A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS SOLENOID B FOR TYPE 0, 1, 3, 4, 03, 32, 32R 36 SPOOLS SOLENOID B FOR TYPE 011, 2, 2R SPOOLS 1.13 (28,7) GRIP .88 (22,4) .25 (6,4) 1.63 (41,4) CLEARANCE TO REMOVE COIL 3.43 (87,1) SPACER NO. 10591320 .13 (3,3) #10-20 U.N.C. THREADED x 1.50 (38,1) LONG MOUNTING BOLTS, 4 REQUIRED, TORQUE: 65 LB • IN (7,3 N • M) SOLENOID A FOR TYPE 011, 2, 2R SPOOLS .74 (18,8) 1.30 (33,0) 1.59 (40,4) 3.53 (89,7) 12.43 (315,7) SOLENOID POSITION LIMIT WITH SIDE OUTLET SUBPLATE 6500 Series, Double “EPW” Solenoid Models 6 .92 (23,4) .125 (3,18) LOCATING PIN 4.45 (113,0) D03 PATTERN MANUAL OPERATED MODELS Manual models are lever actuated, with handle positioned in a choice of four positions on either port “A” or por t “B” end of valve. Refer to drawing on page 3 and “Typical Model Code” on page 8. HANDLE POSITION FOR P TO A FOR TYPE 0, 1, 3, 4, 03, 32 32R, 36 SPOOLS; P TO B FOR TYPE 011, 2, 2R SPOOLS .625 (15,88) HANDLE POSITION FOR P TO B FOR TYPE 0, 1, 3, 4 03, 32, 32R, 36 SPOOLS; P TO A FOR TYPE 011, 2, 2R SPOOLS Valves can be mounted without removing nameplate. Openings in nameplate provide access to mounting holes in valve body. Weight (Mass) 3.2 lb (1,5 kg) HANDLE POSITION FOR P TO B FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; P TO A FOR TYPE 011, 2, 2R SPOOLS 14.5° 14.5° .94 (23,9) .38 (9,7) GRIP 2.09 (53,1) 1.30 (33,0) .125 (3,18) LOCATING PIN 1.594 (40,49) 3.53 (89,7) 1.44 (36,6) .37 (9,4) .92 (23,4) 1.250 (31,75) .88 (22,4) 1.75 (44,4) .609 (15,47) 4.03 (102,4) 5.21 (132,3) 5.45 (138,4) .25 (6,4) #10-24 U.N.C. THREADED x .75 (19,0) LONG MOUNTING BOLTS, 4 REQUIRED; TORQUE: 65 LB • IN ( 7,3 N • M) 5.83 WITH HANDLE OFFSET (148,1) 6100 Series, Manual Lever Operated HYDRAULIC PILOTED MODELS Single and double actuator models are available. Overall length of single configuration (not shown) is 5.25 inches (133,4 mm). Valves can be mounted without removing nameplate. Openings in nameplate provide access to mounting holes in valve body. Refer to page 3 for required shifting pressure and volume. Weight (Mass) Single Actuator: 2.5 lb (1,1 kg); Double Actuator: 2.8 lb (1,3 kg) PILOT A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36, SPOOLS; PILOT B FOR TYPE 011, 2, 2R SPOOLS PILOT B FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36, SPOOLS; PILOT A FOR TYPE 011, 2, 2R SPOOLS 6.46 (164,1) 3.53 (89,7) .88 (22,4) HEX 1.47 (37,3) .94 (23,9) .38 (9,7) GRIP 2.11 (53,6) .13 (3,3) ∅ .125 (3,18) 1.30 (33,0) #10-24 U.N.C. THREADED x .75 (19,0) LONG MOUNTING BOLTS, 4 REQUIRED, TORQUE: 65 LB•IN (7,3 N•M) 1.59 (40,4) .37 (9,4) LOCATING PIN 1.250 (31,75) .25 (6,4) .88 (22,4) PILOT PORT (2) NO. 4 S.A.E. .92 (23,4 1.75 (44,4) 6800 Series, Double Hydraulic Piloted Models AIR PILOTED MODELS Single and double actuator models are available. Overall length of single configuration (not shown) is 5.56 inches (141,2 mm). Valves can be mounted without removing nameplate. Openings in nameplate provide access to mounting holes in valve body. Refer to page 3 for required shifting pressure and volume. Weight (Mass) PILOT A FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; PILOT B FOR TYPE 011, 2, 2R SPOOLS PILOT B FOR TYPE 0, 1, 3, 4, 03, 32, 32R, 36 SPOOLS; PILOT A FOR TYPE 011, 2, 2R SPOOLS 7.09 (180,1) 3.53 (89,7) 1.78 (45,2) PILOT PORT (2) 1/8-27 N.P.T. .94 (23,9) .38 (9,7) GRIP 2.11 (53,6) 1.25 (31,8) HEX .13 (3,3) #10-24 U.N.C. THREADED x .75 (19,0) LONG MOUNTING BOLTS, 4 REQUIRED, TORQUE: 65 LB •IN (7,3 N •M) Single Actuator: 2.3 lb (1,0 kg); Double Actuator: 2.5 lb (1,1 kg) 1.30 (33,0) 1.59 (40,4) ∅ .125 (3,18) LOCATING PIN .92 (23,4) 6900 Series, Double Air Piloted Models 7 .37 (9,4) 1.250 (31,75) .88 (22,4) 1.75 (44,4) .25 (6,4) D03 PATTERN Typical Model Code 6 5 4 0 — D03 — 115/DF Valve Size Valve Type R ✳ — — SL — 1 Reverse Flow Operator (Code 4 and 6 Only) D03 — 8 U.S. gpm (30 L/min) Nominal Flow, N.F.P.A. D03 (CETOP 3) Pattern 6 — Subplate Mounted Directional Control — 0 Modification Number R — Code 4: Two Position; Spring Centered, Actuator Offset (Reverse Flow) Code 6: Two Position; Spring Offset (Reverse Flow), Actuator Centered Design Number Actuator 1 5 8 9 — — — — Manual Lever Solenoid Operated Hydraulic Piloted Air Piloted Lever Position (Manual Models Only) A12 A9 A6 A3 B12 B9 B6 B3 Internal Operator 1 — Two Position; Spring Offset (P→B), Actuator Offset (P→A) 2 — Two Position; Spring Offset (P→A), Actuator Offset (P→B) 3 — Two Position; Actuator Offset, Detented for Non-Manual Actuators➀ Three Position; Detented for Manual Lever 4 — Two Position; Spring Centered, Actuator Offset ➁ 5 — Three Position; Spring Centered, Actuator Offset 6 — Two Position; Spring Offset, Actuator Centered➁ 7 — Manual Lever Only; Two Position, Detented — — — — — — — — 12 o’clock position, on port “A” end of valve 9 o’clock position, on port “A” end of valve 6 o’clock position, on port “A” end of valve 3 o’clock position, on port “A” end of valve 12 o’clock position, on port “B” end of valve 9 o’clock position, on port “B” end of valve 6 o’clock position, on port “B” end of valve 3 o’clock position, on port “B” end of valve Options (Solenoid Models Only) ➀ Only available with Type 0, Type 1 and Type 03 spools. ➁ Not available with Manual Lever Operated valves. C M T CG — — — — SL HPT — — BH3A — BH3B — Spools BH5A — A B A B 2➀ 0 BH5B — P T P T A B A B ➀ Available with 115/DF solenoids only. For other voltages, consult the 2R➀ 1 Dynex sales department ➁ Option not available with “EPW” solenoid models. ➂ Option not available with “Plug-In-Terminal” solenoid models. ➃ N.F.P.A. standard T3.539-1980; A.N.S.I. standard B93.55M-1981. P T P T A B A B 3➀ 32➀ P T P T A B A B 4➀ 32R➀ Electrical – Solenoid Options P T P T A B A B 011➀➁ 36➀ P T P T A B 03 P T ➀ Not available with Type 3 Internal Operators (except manual lever models). ➁ Open crossover CSA and UL Recognized Coils (Etched with Symbol)➀ Hand Actuated Manual Override ➁ Terminal Strip➁➂ Cable Grip, for .38 to .44 inch (9,5 to 11,1 mm) O.D. machine tool cable➁➂ Solenoid Lights (Available 115/DF A.C. Only)➁➂ High Pressure Tank Port 2300 psi (160 bar) maximum A.C. models 3000 psi (210 bar) maximum D.C. models 3-pin Connector (N.F.P.A. standard T3.539-1980), for single solenoid models, on port “A” end of valve➁➂➃ 3-pin Connector, for single solenoid models, on port “B” end of valve➁➂➃ 5-pin Connector, for single or double solenoid models, on port “A” end of valve➁➂➃ 5-pin Connector, for single or double solenoid models, on port “B” end of valve➁➂➃ STANDARD SOLENOIDS: 24/DF — Dual Frequency, 24/60, 24/50 115/DF — Dual Frequency, 115/60, 110/50 230/DF — Dual Frequency, 230/60, 220/50 460/DF — Dual Frequency, 460/60, 440/50 12VDC — Direct Current, 12 Volts 24VDC — Direct Current, 24 Volts 12VDC EPW — Explosion Proof Solenoids 24VDC EPW — Explosion Proof Solenoids 115/60 EPW — Explosion Proof Solenoids 110/50 EPW — Explosion Proof Solenoids 220/50 EPW — Explosion Proof Solenoids PLUG-IN TERMINAL SOLENOIDS:➀ 115/HAC — Dual Frequency, 115/60, 110/50 230/HAC — Dual Frequency, 230/60, 220/50 12/HDC — Direct Current, 12 Volts 24/HDC — Direct Current, 24 Volts For Other Voltages, Consult the Dynex Sales Department ➀ Fits DIN Connector Standard 43650 (Hirschmann GDM 209) 8