Protection and Disconnection Equipment for High and Medium Voltage and Transformers Line IUSA is present in Mexico, Europe, Asia, the US, Central and South America. • Established in 1939. • Workforce of over 12,000 employees. • Manufacturing facilities established in Mexico and USA. • More than 6,000 diversified products for construction, metering and industry. • 90% of the companies have ISO-9001:200. UL, ANCE, NMX and ASTM certification, and comply with international regulations applicable to export products. • Proprietary infrastructure and logistics with 22 sales and distribution offices in Mexico and the US. CONTENTS MEDIUM AND HIGH VOLTAGE 3 5 6 6 8 10 13 I. PORCELAIN INSULATORS II. GLASS INSULATORS III. POLYMER INSULATOR IV. CIRCUIT BREAKER V. PORCELAIN BUSHINGS VI. ARRESTERS VII. DISCONNECTOR BLADES TRANSFORMERS 21 22 I. PEDESTAL TYPE DISTRIBUTION TRANSFORMERS II. POST TYPE IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE 2 MEDIUM AND HIGH VOLTAGE I. PORCELAIN INSULATORS Spool-Type Porcelain Insulators General Description Applicable Standards: CFE 52000-55. R3 Code 311023 310953 Catalogue number P-1323 Description Telephone spool type insulator 1 slot P-12341 Spool type insulator DTP-1323 reel CFE brief description Pieces per package 150 50 Dry flashover voltage 60Hz Wet flashover voltage 60Hz Minimal transversal mechanical resistance Diameter and height Minimal leakage distance kV kV kN mm mm 1C 25 12V/ 15H 178 77 x 82 - Strain-Type Porcelain Insulator General Description Applicable Standards: CFE 52000-55. R3 Code Description 311024 311421 310954 Catalogue number Pieces per package Porcelain strain insulator BT P-1351 ball Porcelain strain insulator BT P-1348 fin Porcelain strain insulator BT P-1353 CFE brief description Dry flashover voltage 60Hz 2R 3R 4R 25 35 40 P-1351 P-1353 P-1348 kV Wet flashover voltage 60Hz 50 12 12 Minimal transversal mechanical resistance kV kN 12 18 23 44.5 89.0 89.0 Diameter and height mm 64 x 89 86 x 140 89 x 172 Minimal leakage distance mm 42 58 77 Line Post-Type Porcelain Insulator General Description Applicable Standards: CFE 52000-92, 52000-91. R3 Code 311422 311424 362485 300882 373335 362492 302433 605054 605055 Catalogue number P-2025 P-2035 P-2045 P-2115 P-2122 P-2130 P-2125(Wprotected DF) Description Line post-type porcelain insulator P-2025 Line post-type porcelain insulator P-2035 Line post-type porcelain insulator P-2115 Line post-type porcelain insulator P-2045 Line post-type porcelain insulator P-2122 P / ZC Line post-type porcelain insulator P-2130 P / ZC Line post-type porcelain insulator P-2125 Line post-type porcelain insulator P-2135 Line post-type porcelain insulator P-2145 Old CFE brief description 13PD 22PD 33PD 13PC 22PC 33PC 13PC Current CFE brief description 13PDPG1 22PDPG1 33PDPG1 13PCPG3 22PCPG2 33PCPG2 13PCPG4 Nominal system voltage 13,8 23,0 34,5 13,8 23,0 34,5 13,8 Dry flashover voltage 60Hz 70 95 125 70 95 125 70 Pieces per package 3 2 2 2 2 1 2 2 2 Wet flashover voltage 60 Hz (kV) 40 65 95 40 65 95 40 www.iusa.mx Lightning impulse critical flashover voltage (kV) 120 160 200 120 160 200 120 Maximum radio interference voltage 1000 kHz <100 <100 <200 <100 <100 <200 <100 Mechanical bending resistance (N-m) 12,5 12,5 12,5 12,5 12,5 12,5 12,5 3 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE I. PORCELAIN INSULATORS Column-Type Porcelain Insulator General Description Applicable Standards: NMX-J-250-1. NRF-007-CFE. IEC-60273. R3 Code 102780 102784 102781 102781 Catalogue number C8-125-II C8-150-II C8-170-II C8FA-200-II Description Pieces per package Column-type porcelain insulator C8-125-II Column-type porcelain insulator C8-150-II Column-type porcelain insulator C8-170-II Column-type porcelain insulator C8-200-II 2 2 1 1 Old CFE brief description Nominal system voltage (kV) Lightning impulse withstand voltage (kV) Wet withstand voltage 60 Hz (kV) Minimum class II leakage distance (mm) Insulator height (mm) CP8-125-II CP8-150-II CP8-170-II CP8-200-II 13,8 23,0 23,0 34,5 125 150 170 200 50 50 70 70 500 660 850 950 305±1 355±1 445±1 475±1 Maximum radio interference voltage 1000 kHz μV < 50 <100 <100 <100 Mechanical bending resistance (N) Mechanical torsion resistance (N-m) 8000 8000 8000 8000 1,200 1,500 2,000 2,000 Pin-Type Porcelain Insulator General Description Applicable Standards: NMX-J-246-ANCE. CFE 52000-03. R3 Code 310956 310957 310958 Description Pieces per package Pin-type porcelain insulator AT P-2851-A 13.8 kV Pin-type porcelain insulator AT P-3300 23.0 kV Pin-type porcelain insulator AT-4800 34.5 kV Dry flashover voltage 60Hz Wet withstand voltage 60 Hz (kV) 8 4 3 Positive impulse flashover critical voltage Negative impulse flashover critical voltage Maximum radio interference voltage 1000 kHz CFE brief description Nominal system voltage kV kV kV kV kV µV kV kN P-2851-A P-3300 P-4800 13A2 22A2 33A 13,8 23,0 34,5 80 110 125 45 70 80 130 175 200 150 225 265 <100 <100 <200 115 145 165 13,36 13,36 13,36 4 Breakdown voltage at 60Hz Mechanical bending resistance (N-m) Catalogue number MEDIUM AND HIGH VOLTAGE II. GLASS INSULATORS Suspension-Type Tempered Glass Insulator General Description Applicable Standards: NRF-018-CFE-2004. EC 60383-1. ANSI C29.2. R3 Code Description 310950 310961 311682 311401 311402 311403 392914 318712 Catalogue number Suspension-type glass insulator CT-4 Suspension-type glass insulator N-12 Suspension-type glass insulator N-12 C/M Suspension-type glass insulator N-160 Suspension-type glass insulator N-120P Suspension-type glass insulator 160P Suspension-type glass insulator N-160 C/M Suspension-type glass insulator N-111 SN CFE brief description N-12 N-12 CM 13A2 22A2 N-120P 33A CT-4 N-160P N-1115N N-160 N-160 C/M N-160 N-160 C/M Pieces per Crate Pallet Use in zone Normal Corrosion Pollution and/ or corrosion Normal Pollution and/ or corrosion Pollution and/ or corrosion Normal Corrosion Normal Corrosion 6 6 6 3 6 3 3 3 180 210 210 144 144 90 144 90 Minimum leakage distance Test voltage at 50Hz mm 292 292 kV 10 10 Maximum radio interference voltage at 1 MHz µV 50 50 140 445 10 50 100 100 178 7,5 50 65 160 160 540 10 50 110 60 170 170 612 10 50 80 80 80 80 50 50 50 50 125 125 125 125 130 130 130 130 370 370 370 370 10 10 10 10 50 50 50 50 Impulse flashover critical voltage (1, 2/50) Mechanical resistance Impact resistance Routine mechanical load 3s Dry flashover at 60Hz Wet flashover at 60Hz 111 111 Nm 7,0 7,0 kN 55,5 55,5 kV 80 80 kV 50 50 Positive kV 125 125 Negative kV 130 130 111 10 55,5 100 60 140 44 5,0 22,0 60 30 160 10 80,0 100 111 10 55,5 160 160 160 160 10 10 10 10 80 80 80 80 N-12 N-160P N-1115N N-160 N-120P CT-4 www.iusa.mx 5 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE III. POLYMERIC INSULATOR / IV. CIRCUIT BREAKER Suspension-Type Synthetic Insulator General Description Applicable standards: IEC-61109. NRF-005-CFE. R3 Code 339072 339073 339074 Catalogue number ASSI-15 ASII-25 ASII-35 Description Pieces per package Pallet Synthetic polymeric Insulator 15kV Synthetic polymeric Insulator 25kV Synthetic polymeric Insulator 35kV 16 16 16 18 boxes 12 boxes 12 boxes CFE brief description 13SHL45C 23SHL45C 34SHL45C Nominal system voltage Dry flashover voltage 60Hz Wet withstand voltage 60 Hz Positive impulse flashover critical voltage kV kV kV kV 13,8 23,0 34,5 90 130 145 65 110 130 140 215 250 Maximum radio interference voltage 500 kHz Nominal leakage distance Mechanical resistance to stress* Mechanical resistance to torsion µV mm Kn N-m <10 <10 <10 395 770 1,003 45 45 45 47 47 47 *In case of customer request, the mechanical resistance may be 70kN. Fuse Circuit Breaker General Description It protects system lines and different equipment of lines such as: transformers, capacitor banks, primary and branch lines, etc. Fuse circuit breakers are used in 13.8, 23.0, and 34.5kV distribution systems; they provide reliable protection to interrupt power failures or overloads through the fusion of the fuse element within its range of interrupting capacity. TIPO C Designed for outdoor service, these are provided with arcing horns to open under load with a portable breakload tool. The fuse tube is made of fiberglass, epoxy resin and a vulcanized fiber internal coating, which helps arc interruption during failure or excessive overload conditions. Types of Circuit Breakers “C” type circuit breaker of the “APD” family, IUSA brand for areas with normal pollution, nominal voltage of 15, 27, and 38kV. “V” type circuit breaker of the “CPV” family, IUSA brand for areas with normal pollution, nominal voltage of 15, 27, and 38kV. “V” type circuit breaker of the “CPV-C” family, IUSA brand for areas with high pollution, nominal voltage of 15, 27, and 38kV. 6 TIPO V MEDIUM AND HIGH VOLTAGE IV. CIRCUIT BREAKERS Catalogue number Abbreviations APD = IUSA description for type “C” circuit breakers. CPV = IUSA description for type “V” circuit breakers. CPV-C = IUSA description for type “V” circuit breakers for areas with high pollution. 15, 27, and 38 = Maximum design voltage in kV. 05 and 12 = Asymmetrical interrupting current in kA. 100 = Nominal current in A. General Specifications Applicable standards: ANSI C37.42. Specification: CFE V4100-03. R3 Code 385973 385975 385971 310720 310721 310959 311449 311451 311452 311453 311454 Catalogue number APD-1512100 APD-27-12-100 APD-3805100 CPV-1512100 CPV-2712100 CPV-3805100 CPV-C-1512100 CPV-C-2712100 CPV-C-3805100 Description Pollution circuit breaker 1512100 CPV-C “V” Pollution circuit breaker 2712100 CPV-C “V” Pollution circuit breaker 3805100 CPV-C “V” Circuit breaker APD-1512100 “C” Circuit breaker APD-2712100-150 “C” Circuit breaker APD-3805100-200 “C” Circuit breaker CPV-1512100-110 “V” Circuit breaker CPV-2712100-150 “V” Circuit breaker CPV-3805100-200 “V” Spare Bobbin APD-1512100 E20 Spare Bobbin APD-2712100 E20 CFE brief description CF-15-100-110-8000 CCF-15-100-110-10000 CCF-15-100-110-12000 CCF-27-100-150-8000 CCF-27-100-150-12000 CCF-38-100-200-2000 CCF-38-100-200-5000 CCF-15-100-110-8000 CCF-15-100-110-10000 CCF-15-100-110-12000 CCF-27-100-150-8000 CCF-27-100-150-12000 CCF-38-100-200-2000 CCF-38-100-200-5000 CCF-C-15-100-110-8000 CCF-C-15-100-110-10000 CCF-C-15-100-110-12000 CCF-C-27-100-150-8000 CCF-C-27-100-150-12000 CCF-C-38-100-200-2000 CCF-C-38-100-200-5000 Maximum design voltage in effective kV 15 15 15 27 27 38 38 15 15 15 27 27 38 38 15 15 15 27 27 38 38 Dry at 60Hz 1 min effective kV 35 35 35 70 70 95 95 35 35 35 70 70 95 95 35 35 35 70 70 95 95 Pieces per Package 1 1 1 1 1 1 1 1 1 20 20 From terminal From terminal to terminal Wave Test to ground, impulse 1,2 Dry at Wave impulse voltage at wet, at / 50 60Hz 60Hz 1,2 / 50 60 Hz Effective Peak 1 min Peak kV kV kV kV effect. kV 30 30 30 60 60 80 80 30 30 30 60 60 80 80 30 30 30 60 60 80 80 110 110 110 150 150 200 200 110 110 110 150 150 200 200 110 110 110 150 150 200 200 35 35 35 70 70 95 95 35 35 35 70 70 95 95 35 35 35 70 70 95 95 www.iusa.mx 110 110 110 150 150 200 200 110 110 110 150 150 200 200 110 110 110 150 150 200 200 9,41 9,41 9,41 15,7 15,7 22 22 9,41 9,41 9,41 15,7 15,7 22 22 9,41 9,41 9,41 15,7 15,7 22 22 Leakage Opening angle distance Maximums at 1MHz Nominal Asymmetric μV A A mm º 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 250 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 8,000 10,000 12,000 8,000 12,000 2,000 5,000 8,000 10,000 12,000 8,000 12,000 2,000 5,000 8,000 10,000 12,000 8,000 12,000 2,000 5,000 210 210 210 432 432 660 660 246 246 246 520 520 870 870 246 246 246 660 660 870 870 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 160 7 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE V. PORCELAIN BUSHING Low Voltage Porcelain Bushing General Description Porcelain bushing with eyebolt and flange for low voltage. General Specifications Device used in distribution transformers, on the low voltage side, to conduct a specific current from the winding, thus providing effective insulation outdoors. R3 Code 311501 311503 311505 311506 311500 311504 377258 Description Porcelain low voltage bushing 10010-H mm 100A Porcelain low voltage bushing 10025-H mm 250A Porcelain low voltage bushing 10050-H mm 500A Porcelain low voltage bushing 10075-H mm 750A Porcelain low voltage bushing 10010-A 100A Porcelain low voltage bushing 10050-A 500A/750A Porcelain low voltage bushing 750A Technical Specifications Pieces per package 16 12 6 6 16 6 6 Values Unit Type of Insulation (B.T) Maximum design voltage to ground Basic level of insulation to the BIL impulse 1.2 kV 0.75 kV Complete wave 1,2 x 50 µs 30 kV Dry (1 min) 10 kV at 60 Hz Withstand voltage Wet (10 sec) 6 kV To the complete wave impulse 1,2x50 30 kV 36 kV Peak voltage Flashover to the cut wave impulse at 1,2 x 50 µs Minimum time 1 µs 3,000 m Maximum operation altitude Operation temperature range from -10 to +50 ° C Catalog number Full Bushing 10010-H 10025-H 10050-H 10075-H 10100-H 8 Current Only the porcelain 10025-A 10050-A 10100-A Nominal at 100 250 500 750 1,000 MEDIUM AND HIGH VOLTAGE V. PORCELAIN BUSHING Medium Voltage Porcelain Bushing Distribution-Type General Description Porcelain medium voltage bushing with connector, inner flange, and outer flange for distribution equipment. General Specifications Device used in distribution transformers, on the medium voltage side, to conduct a specific current to the windings, providing effective insulation outdoors. The porcelain can be provided as a stand-alone unit, or the bushing with interior cable or copper rod. Applicable Standards: NMX-J-234-ANCE. NRF-008-CFE. R3 Code 311471 311492 311472 311476 311487 311477 311480 311499 311481 311483 311496 311495 311484 311473 311489 326073 320554 311475 311478 318691 318694 377247 Description Medium voltage bushing 18415-CI mm 15.0 kV Medium voltage bushing 18415-CC mm 15.0 kV Medium voltage bushing 18415-CH mm 15.0 kV Medium voltage bushing 18423-CI mm 25.0 kV Medium voltage bushing 18423-CC mm 25.0 kV Medium voltage bushing 18423-CH mm 25.0 kV Medium voltage bushing 18434-CI mm 34.5 kV Medium voltage bushing 18434-CC mm 34.5 kV Medium voltage bushing 18434-CH mm 24.5 kV Medium voltage bushing 18415-CITT mm 15.0 kV Medium voltage bushing 18415-CCTT mm Medium voltage bushing 18415-CHTT mm Medium voltage bushing 18434-CCTT mm 34.5 kV Medium voltage bushing 18415-LH 15.0 kV Medium voltage bushing 18423-LH mm 25.9 kV Medium voltage bushing 18423-CB 25.0 kV Medium voltage bushing 18434-LA 34.5 kV Medium voltage bushing 18423-CI 25.0 kV Medium voltage bushing 18434-CC 34.5 kV Medium voltage bushing 18415-LC 15.0 kV Medium voltage bushing 18423-LI mm 23.0 kV Medium voltage bushing 18434-CA 34.5 kV 4 4 9 9 9 9 2 2 1 9 9 9 2 2 2 9 1 9 2 9 2 2 ELECTRICAL CHARACTERISTICS Technical Specifications Nominal system voltage Type of Insulation Maximum design voltage to ground BIL-wave 1,2 x 50 µs Withstand voltage Pieces per Package at 60 Hz Critical flashover voltage to the cut wave impulse Radio interference maximum voltage at 1MHz Flashover distance Minimum leakage distance Nominal voltage Maximum operation altitude Temperature range Dry (1 min) Wet (10 sec) To the complete wave impulse Peak voltage Minimum flashover time 13.8 15 10 95 50 45 95 110 1.6 50 152 279 www.iusa.mx Values 23 25 16 150 60 50 150 175 3 100 203 432 34.5 13.8TT 35 15 22.5 10 200 95 80 50 75 45 200 95 230 110 3 1.6 150 50 305 250 660 440 250 3,000 from -10 to +50 Unit 34.5 TT 35 27.5 200 80 75 200 230 3 150 390 960 kV kV kV kV kV kV kV kV µs µV mm mm A m °C 9 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE V. PORCELAIN BUSHING / VI. ARRESTERS Nominal voltage Stand-alone porcelain (A) P-18415CA 13,8 kV 23 kV P-18415CATT P-18423CA P-18423LA P-18434CA P-18434LA P-18434CATT 34,5 kV COMPONENTS M8 connector, cable, M8 connector, cable, exterior flange seal, 3/8” seal without flange seal, brackets, flange M10 screws (B) (C) P-18415CB P-18415CC P-18415LA P-18415LC P-18415CBTT P-18415CCTT P-18423CB P-18423CC P-18423LB P-18423LC P-18434CB P-18434CC P-18434LB P-18434LC P-18434CBTT P-18434CCT NOTES: C-SHORT TAIL L-LONG TAIL TT-COAST TYPE A B C I H Metal Oxide Ceramic Arresters General Specifications Applicable Standards: IEC 60099-4. NMX-J-321-ANCE. CFE-43 VA400. R3 Code 311462 311692 310722 311463 311026 311693 311027 311694 311466 327229 311467 311691 10 Description Distribution arrester 9/10kV APMOA 10kA Distribution arrester 9/10kV APMOAC 10kA coast type Distribution arrester 12kV APMOA 10kA Distribution arrester 12kV APMOAC 10kA coast type Distribution arrester 18kV APMOA 10kA Distribution arrester 18kV APMOAC 10kA coast type Distribution arrester 21kV APMOA 10kA Distribution arrester 21 kV APMOAC 10kA coast type Distribution arrester 27kV APMOA 10kA Distribution arrester 27kV APMOAC 10kA coast type Distribution arrester 30kV APMOA 10kA Distribution arrester 30kV APMOAC 10kA coast type Pieces per box Pallet 1 90 1 90 1 90 1 90 1 64 1 64 1 64 1 64 1 56 1 56 1 56 1 56 M8 connector, cable, 3/8” seal, interior flange, seal for flange, spring (I) P-18415CI P-18415LI P-18415CITT P-18423CI P-18423LI P-18434CI P-18434LI P-18434CITT M12 connector and rod, cap and seal for flange, brackets, M12 screws and nuts (H) P-18415CH P-18415LH P-18415CHTT P-18423CH P-18423LH P-18434CH P-18434LH P-18434CHTT MEDIUM AND HIGH VOLTAGE VI. ARRESTERS INSULATION WITHSTAND TENSION Catalogue number CFE short description Pollution level Nominal arrester voltage APMOA – 10 APMOAC-10 APMOA - 12 APMOAC-12 APMOA -18 APMOAC-18 APMOA-21 APMOAC-21 APMOA-27 APMOAC-27 APMOA -30 APMOA -30 ADOM-10 ADOMC-10 ADOM-12 ADOMC-12 ADOM-18 ADOMC-18 ADOM-21 ADOMC-21 ADOM-27 ADOMC-27 ADOM-30 ADOMC-30 MEDIUM HIGH MEDIUM HIGH MEDIUM HIGH MEDIUM HIGH MEDIUM HIGH MEDIUM HIGH 10 10 12 12 18 18 21 21 27 27 30 30 To impulse 1.2/50 μ 75 75 85 85 125 125 125 125 150 150 150 150 60Hz effective in wet 1 min (effective kV) 24,0 24,0 27,0 27,0 36,0 36,0 36,0 36,0 60,0 60,0 60,0 60,0 To voltage impulse due T.C.O. (effective to movement kV) 30/60 μ (peak kV) 8,4 26,5 8,4 26,5 10,2 31,8 10,2 31,8 15,3 47,7 15,3 47,7 17 55,6 17 55,6 22 71,5 22 71,5 24,4 79,5 24,4 79,5 Minimum leakage distance mm 440 440 440 440 645 645 645 645 950 950 950 950 To steep impulse voltage 1/20 μ a (peak kV) To lightning voltage impulse 8/20 μ a (peak kV) Maximum value of partial discharges (PD) 39,8 39,8 47,5 47,5 70,5 70,5 74,9 74,9 95,2 95,2 105,9 105,9 33 33 40 40 60 60 70 70 89 89 99 99 10 10 10 10 10 10 10 10 10 10 10 10 Polymer Arrester General Description Metal oxide arresters with polymeric enclosure. They are smaller and weigh less. Great flexibility to achieve the leakage distance values through outer insulator rings, shortening the length of the arrester body. Its silicone enclosure is greatly hydrophobic and UV resistant; it limits leakage currents, eliminates the costs of washing and can increase the life of the equipment. They can be used in highly polluting environments. General Specifications Certified and approved by the CFE (LAPEM) laboratories. Applicable Standards: IEC 60099-4. NMX-J-321-ANCE. NERF-004-C.F.E. R3 Code 362422 362423 362424 370418 370419 370420 370421 370422 374222 374221 374219 370423 370424 370425 370426 370427 370428 370429 370430 370431 Description DISTRIBUTION ARRESTER 12kV APSIL-10kA DISTRIBUTION ARRESTER 24kV APSIL-10kA DISTRIBUTION ARRESTER 30kV APSIL-10kA DISTRIBUTION ARRESTER 10kV APSIL-10kA DISTRIBUTION ARRESTER 10kV APSILC-10kA DISTRIBUTION ARRESTER 10kV APSILC-10kA MTR DISTRIBUTION ARRESTER 12kV APSILC-10kA DISTRIBUTION ARRESTER 12kV APSILC-10kA MTR DISTRIBUTION ARRESTER 15kV APSIL-10kA DISTRIBUTION ARRESTER 15kV APSILC-10kA DISTRIBUTION ARRESTER 15kV APSILC-10kA MTR DISTRIBUTION ARRESTER 18kV APSIL-10kA DISTRIBUTION ARRESTER 18kV APSILC-10kA DISTRIBUTION ARRESTER 18kV APSILC-10kA MTR DISTRIBUTION ARRESTER 21kV APSIL-10kA DISTRIBUTION ARRESTER 21kV APSILC-10kA DISTRIBUTION ARRESTER 21kV APSILC-10kA MTR DISTRIBUTION ARRESTER 24kV APSIL-10kA L y F DISTRIBUTION ARRESTER 24kV APSILC-10kA DISTRIBUTION ARRESTER 24kV APSILC-10kA MTR Pieces per Package www.iusa.mx 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 11 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE VI. ARRESTERS R3 Code 370432 370433 370434 370435 370436 Description Pieces per package DISTRIBUTION ARRESTER 27kV APSIL-10kA DISTRIBUTION ARRESTER 27kV APSILC-10kA DISTRIBUTION ARRESTER 27kV APSILC-10kA MTR DISTRIBUTION ARRESTER 30kV APSILC-10kA DISTRIBUTION ARRESTER 30kV APSILC-10kA MTR 1 1 1 1 1 WITHSTAND VOLTAGE TO INSULATION Catalogue number CFE short description Pollution level Nominal arrester voltage To impulse 1.2/50 μ (peak kV) APSIL-10 ADOM-10 ADOMC-10 ADOM-12 ADOMC-12 ADOM-18 ADOMC-18 ADOM-21 ADOMC-21 ADOM-27 ADOMC-27 ADOM-30 ADOMC-30 MEDIA ALTA MEDIA ALTA MEDIA ALTA MEDIA ALTA MEDIA ALTA MEDIA ALTA 10 10 12 12 18 18 21 21 27 27 30 30 75 75 85 85 125 125 125 125 150 150 150 150 APSIL-12 APSIL-18 APSIL-21 APSIL-27 APSIL-30 Maximum residual voltage 60Hz effective in wet 1 min (effective kV) Minimum leakage distance (mm) T.C.O. (effective kV) 24,0 24,0 27,0 27,0 36,0 36,0 36,0 36,0 60,0 60,0 60,0 60,0 495 495 495 495 830 830 830 830 1030 1030 1030 1030 8,4 28,4 10,2 10,2 15,3 15,3 17 17 22 22 24,4 24,4 To voltage impulse due to movement 30/60 μ (peak kV) 29 29 35 35 53 53 61 61 79 79 87 87 To steep impulse voltage 1/20 μ a (peak kV) To lightning voltage impulse 8/20 μ (peak kV) Maximum value of partial discharges 36 36 44 44 65 65 76 76 98 98 108 108 40 40 48 48 72 72 84 84 108 108 120 120 10 10 10 10 10 10 10 10 10 10 10 10 IUSA APLEA Polymer Arrestor General Description The IUSA APLEA (Line Arrestors with Air Gap) is equipment to be installed in parallel with line insulators, without mechanical load, that limits surges and arc currents caused by lighthning discharges through an air gap electrode and metal oxide nonlinear resistors that extinguish the arc produced between the electrode and the distribution line cable. Opposed to conventional arrestors, these are disconnected from the distribution line by an air gap that allows controlling the discharges it extinguishes, as demonstrated in the tests performed, which obtained satisfactory results according to specification CFE 52000-66. The design of its silicon rubber sleeve ensures that the arrestor will not release highspeed solid residues and is compliant to be installed under normal and high pollution environmental conditions. IUSA CFE short brochure description APLEA13 APLEA23 APLEA33 12 ALEA13 ALEA23 ALEA33 Nominal system voltage (kV) Critical flashover current to impulse by positive lightning 1,2/50fs (kV) Minimum flashover current at 60Hz dry (kV) Minimum flashover current at 60Hz we t (kV) Length (mm) Nominal arc distance (mm) 13.8 23 34.5 90 125 150 35 50 55 25 40 4 129 168 222 40 60 65 MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES Single-Pole Or Monopole Blade (P) Overview The blades are single-pole or monopole operation type pole unloaded. Outdoors service for distribution substations. Nominal design voltage from 15 to 38kV. Rated from 630 to 2000 A. Basic lightning Impulse insulation Level (BIL) from 125 to 200kV. Applicable for the distribution system. General Specifications International standards: IEC-62271-102. IEC-60694. National Standards: NMX-J-356-ANCE. Specifications: CFE V4200-25. R3 Code Description Pieces per package 311517 311521 311703 311523 311704 311515 311518 311705 326326 327666 311516 311519 318722 311522 311702 311520 Single-pole Blade P-12125 Single-pole Blade P-12150 Single-pole Blade P-12170 Single-pole Blade P-12200 Single-pole Blade P-12250 Single-pole Blade P-20125 Single-pole Blade P-20150 Single-pole Blade P-20170 Single-pole Blade P-20200 Single-pole Blade P-20250 Single-pole Blade P-63125 Single-pole Blade P-63150 Single-pole Blade P-63170 Single-pole Blade P-63200 Single-pole Blade P-63250 Single-pole Blade XP-23600-1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 1 BASIC LIGHTNING IMPULSE INSULATION LEVEL (BIL) KV (PEAK) Catalogue number CFE short description WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) Nominal design Closed to Open through voltage of the Closed to ground and ground and the distance equipment Vn between poles between poles of insulation effective kV Open through the distance of insulation dry 1 min. wet 10 sec. dry 1 min. P-63125 P-63150 P-63200 P-12125 P-12150 P-12200 P-20125 CSP-125-1-15,5-630 CSP-150-1-25,8-630 CSP-200-1-38-630 CSP-125-1-15,5-1250 CSP-150-1-25,8-1250 CSP-200-1-38-1250 CSP-125-1-15,5-2000 15 25.8 38 15 25.8 38 15 125 150 220 125 150 200 125 145 165 220 145 165 220 145 70 70 95 70 70 95 70 www.iusa.mx 60 60 80 60 60 80 60 77 77 105 77 77 105 77 TEST VALUE OF THE WITHSTAND CURRENT Nominal Short current duration Peak value wet 10 sec. A kA (1 sec) kA 66 66 88 66 66 88 66 630 630 630 1250 1250 1250 2000 25.00 25.00 25.00 38.10 38.10 38.10 43.80 65.00 65.00 65.00 99.06 99.06 99.06 113.80 13 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES Three-Pole Blade (TP-II) General Description The three-pole blades are of the no-load operation group. Outdoors service for distribution substations. Mounting type: vertical, horizontal. Nominal design voltage from 15,5 to 38 kV. Nominal current from 630 to 2000 A. Basic lightning Impulse insulation Level (BIL) from 125 to 200 kV Applicable to the distribution system. General Specifications International. R3 Code Description 395833 395832 395831 395830 395829 395828 395827 395826 395825 395824 339151 377001 Three-pole blade TPII 12125 Three-pole blade TPII 12150 Three-pole blade TPII 12170 Three-pole blade TPII 12200 Three-pole blade TPII 12250 Three-pole blade TPII 63125 Three-pole blade TPII 63150 Three-pole blade TPII 63170 Three-pole blade TPII 63200 Three-pole blade TPII 63250 Three-pole blade TPII 20125 Three-pole blade TPII 20200 Pieces per package 1 1 1 1 1 1 1 1 1 1 1 1 BASIC LIGHTNING IMPULSE INSULATION LEVEL (BIL) KV (PEAK) Catalogue number CFE short description WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) Nominal design Closed to Open through voltage of the Closed to ground and ground and the distance equipment Vn between poles between poles of insulation effective kV Open through the distance of insulation dry 1 min. wet 10 sec. dry 1 min. TPII-63125 TPII-63150 TPII-63200 TPII-12125 TPII-12150 TPII-12200 TPII-20125 14 CSP-125-1-15,5-630 CSP-150-1-25,8-630 CSP-200-1-38-630 CSP-125-1-15,5-1250 CSP-150-1-25,8-1250 CSP-200-1-38-1250 CSP-125-1-15,5-2000 15 25.8 38 15 25.8 38 15 125 150 220 125 150 200 125 145 165 220 145 165 220 145 70 70 95 70 70 95 70 60 60 80 60 60 80 60 77 77 105 77 77 105 77 TEST VALUE OF THE WITHSTAND CURRENT Nominal Short current duration Peak value wet 10 sec. A kA (1 sec) kA 66 66 88 66 66 88 66 630 630 630 1250 1250 1250 2000 25.00 25.00 25.00 38.10 38.10 38.10 43.80 65.00 65.00 65.00 99.06 99.06 99.06 113.80 MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES Vertical Opening Blade (TTR6) For Distribution And Transmission General Description The TTR6 blades are group operation non-load blades. Outdoors service for distribution substations. Mounting type: vertical, horizontal. Nominal design voltage from 15 to 170 kV. Nominal current design from 630 to 2000 A. Basic lightning Impulse insulation Level (BIL) from 125 to 750 kV. It can be supplied for design voltages above 123 kV with ground blade as required. General Specifications International standards: IEC 271-102. IEC-60694. National Standards: NMX - J-356. Specifications: CFE V4200-25. CFE V4200-12. R3 Code Description 311708 311709 318724 311706 311028 390988 311707 390987 311525 379359 335252 327667 327668 Blade TTR-6 125-2000 Blade TTR-6 150-2000 Blade TTR-6 170-2000 Blade TTR-6 450-1250 Blade TTR-6 550-1200 Blade TTR-6 550-2000 Blade TTR-6 650-1200 Blade TTR-6 650-2000 Blade TTR-6 750-1250 Blade TTR-6 950-1600 Blade TTR-6-200-2000 Blade AG-7 TTR-6 115/138 kV Blade AG-7 TTR-6 15.5 kV Pieces per package 1 1 1 1 1 1 1 1 1 1 1 1 1 TTR6 FOR DISTRIBUTION UP TO 25.8KV BASIC LIGHTNING IMPULSE INSULATION LEVEL (BIL) KV (PEAK) Catalogue number CFE short description WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) Nominal design Closed to Open through voltage of the ground Closed to ground and the distance equipment Vn and between between poles of insulation effective kV poles Open through the distance of insulation dry 1 min. wet 10 sec. dry 1 min. wet 10 sec. TTR-6-125-630 TTR-6-125-1250 TTR-6-125-2000 TTR-6-150-630 TTR-6-150-1250 CSA-125-3-15,5-630 CSA-125-3-15,5-1250 CSA-125-3-15,5-2000 CSA-150-3-25.8-630 CSA-150-3-25.8-1250 15.5 15.5 15.5 25.8 25.8 125 125 125 150 150 145 145 145 165 165 70 70 70 70 70 www.iusa.mx 60 60 60 60 60 77 77 77 77 77 66 66 66 66 66 TEST VALUE OF THE WITHSTAND CURRENT Nominal Short duration Peak value current A kA (1 sec) kA 630 1250 2000 630 1250 25.00 38.10 43.80 25.00 38.10 65.00 99.06 113.8 65.00 99.06 15 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES TTR6 FOR TRANSMISSION SYSTEM BASIC LIGHTNING IMPULSE INSULATION LEVEL (1,2/50 MICROSEC.) (PEAK KV) Catalogue number TTR-6-550-1250 TTR-6-550-1600 TTR-6-550-2000 TTR-6-650-1250 TTR-6-650-1600 TTR-6-650-2000 TTR-6-650-1250 TTR-6-650-1600 TTR-6-650-2000 TTR-6-750-1250 TTR-6-750-1600 TTR-6-750-2000 TTR-6-750-1250 TTR-6-750-1600 TTR-6-750-2000 CFE short description Nominal design Nominal design voltage of the voltage of blade system Vn effective effective kV kV CSA-550-3-123-1250-MH/MV CSA-550-3-123-1600-MH/MV CSA-550-3-123-2000-MH/MV CSA-650-3-123-1250-MH/MV CSA-650-3-123-1600-MH/MV CSA-650-3-123-2000-MH/MV CSA-650-3-145-1250-MH/MV CSA-650-3-145-1600-MH/MV CSA-650-3-145-2000-MH/MV CSA-750-3-145-1250-MH/MV CSA-750-3-145-1600-MH/MV CSA-750-3-145-2000-MH/MV CSA-750-3-170-1250-MH/MV CSA-750-3-170-1600-MH/MV CSA-750-3-170-2000-MH/MV 115 115 115 115 115 115 138 138 138 138 138 138 161 161 161 123 123 123 123 123 123 145 145 145 145 145 145 170 170 170 Common values Open between contacts of the blade 550 550 550 650 650 650 650 650 650 750 750 750 750 750 750 630 630 630 750 750 750 750 750 750 860 860 860 860 860 860 Central Lateral Opening Blade (DRV) For Distribution And Transmission General Description The DRV blades are of the central lateral opening type; the position of the insulators is in “V”, operating in non-load group, with or without ground connection, manually operated or motorized mechanisms. Outdoors service for distribution substations. Mounting type: vertical, horizontal. Nominal design voltage from 72.5 to 170kV. Nominal current from 800 to 2000 A. Basic lightning Impulse insulation Level (BIL) from 450 to 750kV. It can be supplied for design voltages above 123 kV with ground blade as required. General Specifications International standards: IEC-62271-102. IEC-60694. National Standards: NMX-J-356-ANCE. Specifications: CFE V4200-25. CFE V4200-12. R3 Code Description 335254 335255 379334 335253 376264 Knife-blade DRV 550-1250 Knife-blade DRV 650-1250 Knife-blade DRV 750-1600 Knife-blade DRV-450-1250 Knife-blade DRV 550 2000A 16 Pieces per package 1 1 1 1 1 WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) TEST VALUE OF THE WITHSTAND CURRENT Common values Open between Nominal contacts of current the blade Dry/wet 1 min. 230 230 230 275 275 275 275 275 275 325 325 325 325 325 325 Dry/wet 10 sec. 265 265 265 315 315 315 315 315 315 375 375 375 375 375 375 Short Peak value duration A kA (1 sec) kA 1250 1600 2000 1250 1600 2000 1250 1600 2000 1250 1600 2000 1250 1600 2000 31.50 40.00 40.00 31.50 40.00 40.00 31.50 40.00 40.00 31.50 40.00 40.00 31.50 40.00 40.00 81.90 104.00 104.00 81.90 104.00 104.00 81.90 104.00 104.00 81.90 104.00 104.00 81.90 104.00 104.00 MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES DRV BLADES FOR DISTRIBUTION BASIC LIGHTNING IMPULSE WITHSTAND VOLTAGE TO INSULATION LEVEL (1,2/50 SYSTEM FREQUENCY MICROSEC.) (PEAK KV) KV (EFFECTIVE) Catalogue number DRV-550-800 DRV-550-1250 DRV-650-800 DRV-650-1250 CFE short description CSV-550-3-123-800-MV/MH CSV-550-3-123-1250-MV/MH CSV-650-3-145-800-MV/MH CSV-650-3-145-1250-MV/MH Nominal design Closed to ground Open through Open through the Closed to ground voltage of the system and between the distance of distance and between poles Vn effective kV poles insulation of insulation 123 123 145 145 550 550 650 650 630 630 750 750 dry/wet 1 min. 230 230 275 275 dry/wet 1 min. 265 265 315 315 TEST VALUE OF THE WITHSTAND CURRENT Nominal current Short duration Peak value A kA (1 sec) kA 800 1250 800 1250 25 31.5 25 31.5 65 81.9 65 81.9 DRV BLADES FOR TRANSMISSION SYSTEM BASIC LIGHTNING IMPULSE WITHSTAND VOLTAGE TO INSULATION LEVEL (1,2/50 SYSTEM FREQUENCY MICROSEC.) (PEAK KV) KV (EFFECTIVE) Catalogue number DRV-550-1250 DRV-550-1600 DRV-550-2000 DRV-650-1250 DRV-650-1600 DRV-650-2000 DRV-650-1250 DRV-650-1600 DRV-650-2000 DRV-750-1250 DRV-750-1600 DRV-750-2000 Nominal design voltage of the system Vn effective kV 115 115 115 115 115 115 138 138 138 161 161 161 Nominal design voltage of the blade Vn effective kV Common values 123 123 123 123 123 123 145 145 145 170 170 170 550 550 550 650 650 650 650 650 650 750 750 750 Open between the contacts of the blade 630 630 630 750 750 750 750 750 750 860 860 860 Common values dry/wet 1 min. 230 230 230 275 275 275 275 275 275 325 325 325 Open between the contacts of the blade dry/wet 1 min. 265 265 265 315 315 315 315 315 315 375 375 375 TEST VALUE OF THE WITHSTAND CURRENT Nominal current Short duration A kA (1 sec) kA 1250 1600 2000 1250 1600 2000 1250 1600 2000 1250 1600 1600 31.50 40.00 40.00 31.50 40.00 40.00 31.50 40.00 40.00 31.50 40.00 40.00 81.90 104.00 104.00 81.90 104.00 104.00 81.90 104.00 104.00 81.90 104.00 104.00 Peak value Central Lateral Double Opening Blade (TTT-7) General Description TTT-7 blades are of central lateral double opening, with three columns of insulators. It has a rotating insulator at the center of each pole. It operates in the non-load group; with or without ground connection, motorized drive mechanisms of the main blade. Mounting type: vertical, horizontal. Nominal design voltage from 245 to 420kV. Rated from 1250 to 3150 A. Basic lightning Impulse insulation Level (BIL) from 1050 to 1550kV. General Specifications International standards: IEC-62271-102. IEC-60694. National Standards: NMX-J-356-ANCE. Specifications: CFE V4200-12. www.iusa.mx 17 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES R3 Code Description 362402 318726 311711 311712 318727 318728 318725 318723 383757 Blade TTT-7 1550 3150 A Blade TTT-7 1050-2000-NO Blade TTT-7 1050-1250/1600/2000 Blade TTT-7 1300-1200 Blade TTT-7 1425-2000 Blade TTT-7 1550-2000 Blade TTT-7 AG 400kV Blade TTT-7 AG-7 230kV Blade TTT-7 AG-9 15.5 kV Pieces per package 1 1 1 1 1 1 1 1 1 TTT-7 (245 kV) BASIC LIGHTNING IMPULSE INSULATION LEVEL (1,2/50 MICROSEC.) (PEAK KV) Catalogue number TTT-7-245-1050-2000 TTT-7-245-1175-2000 WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) Nominal design voltage of the system Vn effective kV Nominal design voltage of the blade Vn effective kV Closed to ground and between phases Open through the contacts of the blade Closed to ground and between poles Open through the distance of insulation 230 230 245 245 1050 1175 1200 1175(+205) Dry/ Wet 1min. 460 460 Dry/ Wet 1 min. 530 530 TEST VALUE OF THE WITHSTAND CURRENT Nominal current Short duration Peak value A kA (1 sec) 50.00 50.00 kA 130.00 130.00 2000 2000 TTT-7 (429 kV) BASIC LIGHTNING IMPULSE INSULATION LEVEL (BIL) KV (PEAK) Catalogue number TTT-7-420-1425-2000 TTT-7-420-1550-2000 TTT-7-420-1425-3150 TTT-7-420-1550-3150 WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) BASIC IMPULSE INSULATION LEVEL BY MOVEMENT KV (EFFECTIVE) Nominal Nominal design Closed to Open through the Open through Closed to Open through voltage of the voltage of the Closed to ground ground and contacts of the the distance of ground and the distance of system blade Vn effective and between poles between poles blade insulation between poles insulation effective kV kV Dry/ Wet 1min. Dry/ Wet 1min. 400 420 425 1425(+245) 520 610 1050 900(+345) 400 420 1550 1550(+315) 620 800 1175 900(+450) 400 420 1425 1425(+245) 520 610 1050 900(+345) 400 420 1550 1550(+315) 620 800 1175 900(+450) COGC Blade General Description COGC equipment is comprised by blades in charged group operation, side opening and position of insulators in “V”. Horizontal and vertical utility pole mount without ground connection blade; manual drive mechanism. Outdoor service for the distribution system. Rated voltage design from 15.5 to 25.8 kV. Nominal current of 630 A. Basic lightning Impulse insulation Level (BIL) from 125 to 170kV. General Specifications International standards: IEC 60265-1. IEC-60694. National standards: NMX-J-323. Specifications NRF-006-CFE. 18 TEST VALUE OF THE WITHSTAND CURRENT Nominal current A 2000 2000 3150 3150 Short duration Peak value kA (1 sec) 50.00 50.00 50.00 50.00 kA 130.00 130.00 130.00 130.00 MEDIUM AND HIGH VOLTAGE VII. DISCONNECTOR BLADES R3 Code Description Pieces per package 361863 361864 387311 387312 385967 Pole-mounted blade COGC 15125 Pole-mounted blade COGC 25150 Pole-mounted blade COG-15125 Pole-mounted blade COG-25150 Pole-mounted blade COG-25170 1 1 1 1 1 BASIC LIGHTNING IMPULSE INSULATION LEVEL (BIL) KV (PEAK) Catalogue number CFE short description COGC15125H/V COG15125H/V COGC25150H/V COG25150H/V COGC25170H/V COG25170H/V COGC-15-125V COG-15-125V COGC-25-150V COG-25-150V COGC-25-170V COG-25-170V 250 Nominal design Closed to ground Open through voltage of the and between the distance equipment Vn poles of insulation effective kV 15.5 15.5 25.8 25.8 25.8 25.8 125 125 150 150 170 170 145 145 165 165 195 195 WITHSTAND VOLTAGE TO SYSTEM FREQUENCY KV (EFFECTIVE) Closed to ground and between poles dry 1 min. wet 10 sec. 70 70 70 70 80 80 60 60 60 60 70 70 www.iusa.mx Open through the distance of insulation dry 1 min. 77 77 77 77 88 88 TEST VALUE OF THE WITHSTAND CURRENT Nominal current wet 10 sec. A 66 66 66 66 77 77 630 630 630 630 630 630 Short duration Peak value kA (1 sec) kA 16 25 16 25 16 25 19 IUSA | Transformers TRANSFORMERS 20 TRANSFORMERS I. PEDESTAL TYPE DISTRIBUTION TRANSFORMERS Single-Phase Pad-Mount Type Distribution Transformers General Description Single-phase distribution pedestal transformers. General Specifications From 25 kVA to 100 kVA in carbon steel or stainless steel. Primary voltage: Volts 13200YT/7620. Secondary voltage: 240/120 volts. Secondary connection: 1 phase, 3 wires. Frequency: 60 Hz. Overheating temperature 65º C or 55° C for the coast type. Branch joints to full capacity: (4) 2 up, 2 down 2.5% each . Operating altitude: 2300 meters above sea level. Cooling type: self-cooling-OA. Overload protection: oil-immersed bayonet expulsion fuse, operated from the outside in series with another internal-mount current-limiting fuse. Secondary circuit, oil operation (optional). High-voltage terminals: dead front with two well bushings, one in ring configuration and the other in radial operation. Low-voltage terminals: three spade-type bushings. Manufacturing standards: NMX-J-285-ANCE. Specification: K-CFE 0000-04. Three-Phase Pedestal Distribution Transformers General Description Three-phase distribution pedestal transformers. General Specifications From 30 to 500 kVA in carbon steel or stainless steel. Primary Voltage: 13200YT/7620 volts. Primary Connection: star. Secondary Voltage: 220/127 Volts. Secondary connection: star. Frequency: 60 Hz. Overheating temperature 65º C or 55° C for coast type. Branch joints to full capacity: (4) 2 up, 2 down 2.5% each . Operating altitude: 2300 meters above sea level. Cooling type: self-cooling-OA. Overload protection, oil-immersed bayonet expulsion fuse, operated from the outside in series with another internal-mount current-limiting fuse. With partial or full range, two-position disconnector. High-voltage terminals: dead front with well bushings up to 500 kVA, 200 amperes. Well bushings up to 500 kVA, with six bushings for ring configuration operation and three for radial operation. Low-voltage terminals: four spade-type bushings. Manufacturing standards: NMX-J-285-ANCE. Specification: K-0000 CFE-07 and K-0000-08. We also carry the NMX-J-285 Delta-Star and Star-Star from 225 kVA to 2500 kVA. Class 25 kV and 34.5 kV in development. www.iusa.mx 21 IUSA | Transformers Protection and Disconnection Equipment for High and Medium Voltage and Transformers TRANSFORMERS II. POST TYPE IUSA Prisma Phase Converter Post-Type General Description The PRISMA phase converter operates by delivering three-phase electric power from a single-phase source. It operates in medium voltage with two phases, two wires, and provides—in low voltage—three-phase voltage values on four wires. This differentiates the PRISMA IUSA phase converter from transformers, selftransformers, or converters, whether electronic, with capacitors, or of the generator type. Our converter behaves as a voltage source connected at medium voltage to an infinite bar (as could be the medium voltage terminals from the power supply company at 33kV, 25kV, 15kV), limiting the power delivered to working elements of the equipment, delivering three-phase power on the low voltage side (it is reversible). Thus, three-, two-, or single-phase loads—resistive, inductive, or capacitive—can be connected to its output terminal blocks at any secondary voltage value used worldwide. General Specifications IUSA Prisma Phase Converter Post-Type CLASS Primay voltage Secondary voltage Frequency Overheating Operating altitude Type of cooling Surge protection Medium voltage terminals Low voltage terminals Specification Standards applicable to product 13200 volts 23000 volts 33000 volts It can be: 440/254 volts, 380/220 volts, 220/127 volts, or any that is necessary. 60 Hz 65° or 55° C for warm climate 2300 meters above sea level OA None on post type Bushings with ring terminals according to the voltage required. Low voltage bushings with ring terminal. PRISMA IUSA phase converter for distribution, post type and substation type (ETO-120-2/3, 240-2/3). The same specification. APPROXIMATE DIMENSIONS TYPE CLASS 15 POST 22 25 kVA 30 45 75 30 45 75 LENGTH WIDTH HEIGHT WEIGHT mm mm mm kg 700 800 890 780 810 600 450 470 500 480 480 500 600 650 700 600 670 750 420 529 668 474 551 766 TRANSFORMERS POST TYPE IUSA Prisma Pedestal Phase Converter General Description The PRISMA phase converter operates by delivering three-phase electric power from a single-phase source. It operates in medium voltage with two phases, two wires, and provides—in low voltage—three-phase voltage values on four wires. This differentiates the PRISMA IUSA phase converter from transformers, self-transformers, or converters, whether electronic, with capacitors, or of the generator type. Our converter behaves as a voltage source connected at medium voltage to an infinite bar (as could be the medium voltage terminals from the power supply company at 33kV, 25kV, 15kV), limiting the power delivered to working elements of the equipment, delivering three-phase power on the low voltage side (it is reversible). Thus, three-, two-, or single-phase loads— resistive, inductive, or capacitive—can be connected to its output terminal blocks at any secondary voltage value used worldwide. General Specifications IUSA Prisma Pedestal Phase Converter CLASS Primay voltage Secondary voltage Frequency Overheating Operating altitude Type of cooling Surge protection Medium voltage terminals Low voltage terminals Specification 13200 volts 23000 volts 33000 volts It can be: 440/254 volts, 380/220 volts, 220/127 volts, or any that is necessary. 60 Hz 65° or 55° C for warm climate 2300 meters above sea level OA Through limiting fuses according to its capacity. Insert type, according to its voltage. Blade type, according to required capacity. Two-pole medium voltage breaker switch according to its capacity. PRISMA IUSA substation type phase converter (ETO-120-2/3P, 240-2/3P). APPROXIMATE DIMENSIONS TYPE CLASS 15 POST 25 kVA 30 45 75 30 45 75 LENGTH WIDTH HEIGHT WEIGHT mm mm mm kg 905 1085 1085 936 936 1085 980 1030 1030 1010 1010 1030 1100 1100 1100 1100 1100 1100 775 984 1056 836 874 1082 www.iusa.mx 23 IUSA | Protection and Disconnection Equipment for High and Medium Voltage and Transformers 24 PASTEJÉ HEADQUARTERS Km 109, Carretera Panamericana México – Querétaro Jocotitlán, Edo. Méx. C.P. 50700, México For further information: EXPORTS Tel +52 5118 1400 ext. 2210 exportaciones@iusa.com.mx