SPEC-5 Horizontal Compact Fluorescent (1) 13W or 18W Quad Tube Open Recessed Downlight and Wallwasher online Find it Fast Applications: This fixture offers excellent brightness control in a 6" aperture. Suitable for use in offices, stores and lobbies, this recessed downlight has a low profile that allows it to be used in shallow plenum areas. Available in two wattages with a standard electronic ballast. 6" 114 Type:________________________________________ Project:______________________________________ ____________________________________________ ORDERING NOTE: Complete unit consists of rough-in and trim section. Indicate ballast/voltage and desired options. 6202_____ S5D_____ BALLAST/VOLTAGE ROUGH-IN S5D6102 (1) 13W Quad Tube S5D6103 (1) 18W Quad Tube U Universal 120V/277V S3 Dedicated 347V LE1* LUTRON EcoSystem® (5%) 120V LE2* LUTRON EcoSystem® (5%) 277V AM1 ADVANCE® MARK VII® (5%) 120V AM2 ADVANCE MARK VII (5%) 277V AX1* ADVANCE® MARK X® (5%) 120V AX2*ADVANCE MARK X (5%) 277V TRIM TRIM FINISH 6202R Downlight Reflector 6202W Wallwasher Reflector 6202K Corner Wallwasher 6202DDouble Wallwasher * Available in 18W only. Downlight C UL ® S5D6103 shown 6 1/4" 6 3/4" 7 1/4" Wallwasher 3. Mounting Brackets - Adjustable butterfly mounting brackets allow for a vertical adjustment of 2" and accept one piece universal or C-channel mounting bars (ordered as an optional accessory). US LISTED Suitable for damp locations Fixtures with standby battery packs are rated for dry locations only Approved for thru-wiring Above ceiling access not required Thermally protected IBEW Union Made Alzak®is a registered trademark of the Aluminum Company of America. 1. Yoke Assembly - 16 gauge steel yoke assembly is corrosion protected and fixed to the mounting pan. 2. Plaster Frame - 18 gauge galvanized, die-formed plaster frame has a fixed throat depth of 1". 4. Splice Compartment - 18 gauge galvanized splice compartment is U.L. listed for thru-wiring (4 in and 4 out at 90˚C) and has 7/8" knock-outs. Ground wire is supplied. Splice compartment assembly is accessible from below ceiling and is attached to the yoke assembly by contractor. 5. Standby Battery Pack - IOTA I-42, mounted on splice compartment cover. An integral test light/switch, supplied, is accessible and visible through reflector aperture. Operates on 120v or 277v, 60Hz only. Zumtobel Lighting, Inc. ©2013 17-09 Zink Place, Unit 7 Fair Lawn, NJ 07410 845-691-6262 800-932-0633 zli.us@zumtobel.com 06/27/13 www.zumtobel.us C Clear Specular Reflector MC Matte Clear Alzak® Reflector NOTE: Add “E” to end of reflector description for standby fixture. F* Fusing W White painted reflector flange 9930 Set of two 27" C-channel mounting bars 9952 Set of two 52" C-channel mounting bars 9956 Set of two 28" 10 ga. one piece universal mounting bars E4 Standby Battery Pack 120/277v E4 is not available with 347V. *Fusing not available with 347V. 12 1/4"* 10" 6 1/8" 6 1/8" 6 1/4" 6 3/4" 7 1/4" OPTICS S5D6103 shown 10" 12 9/16" S5D6103 shown *11 15/16” for S5D6102 (Ceiling Opening = 6 3/4") 6. Reflector - One piece spun aluminum reflector with 1/2" flat flange with low iridescence, specular clad finish. Clear specular and matte clear Alzak® finishes are available. A white painted reflector flange is also available. The reflector is secured to the yoke assembly by a center screw. 9. Ballast - One (1) lamp, thermally protected Class P electronic ballast is supplied. 7. Wallwasher Reflector - A hydroformed aluminum kicker plate is mounted to the main reflector and is available in three specific configurations for wall illumination. Wallwasher reflector mounts in a fixed orientation. NOTE: National or municipal codes must be followed regarding set back of thermal insulating material from fixture. As a guideline, any insulation materials must be held away from the fixture by a minimum of 3". Fixtures are not designed for direct contact with thermal insulation. 8. Lamp/Socket - (1) 13W or 18W quad tube compact fluorescent lamp with a G24q-1 (13W) or a G24q-2 (18W) socket. Lamp supplied by others. In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials. Technical specification sheets that appear on www.zumtobel.us are the most recent version and supersede all other versions that exist in any other printed or electronic form. EcoSystem ballast is wired to E1 & E2 (not dim hot) unless otherwise specified. 10. Weight - Housing - 4.6 lbs; trim - .05 lbs. Photometric Data S5D6103 6202RC (1) 18W CFL 6" DOWNLIGHT, SPECULAR REFLECTOR LTL 03061 Total Luminaire Efficiency 64% 0% Uplight 100% Downlight Spacing Criteria Lateral Plane 0° 90° 1.4 1.4 TOTAL LAMP LUMENS = 1250 INPUT WATTS = 20 Beam Diameter Candela Distribution 35.0 111.3 170.7 212.7 170.9 97.9 0.5 0.0 0.0 Average 90° 15411 13166 0 0 0 15411 13166 0 0 0 Wall EcoSystem (wired to E1 & E2 – not dim hot) unless otherwise specified 26.7' 3 FC 12' 0' Ceiling 1' 1' 2' 2' 3' 3' 3' 4' 4' 4' 5' 5' 5' 6' 6' 6' 7' 7' 7' 8' 8' 8' 9' 9' floor 9'floor Floor Maximum = Maximum 0.5 72 66 60 55 50 46 42 38 35 33 0.1 72 64 56 50 44 39 35 31 28 26 ceiling ceiling 0' 1' ceiling 1' ceiling 2' 3' 4' 5' 6' 7' 8' 9' floor ▲ 2' 3' 4' 4' 0' 1' 5 12 13 11 8 7 5 4 3 = =2 2' 3' 1' 1' 3' 4' 4' 3' 3' 2' 2'3' 1' 2' 4 3 11 10 14 15 13 13 9 10 7 6 5 5 3 3 AVG AVG / MIN / MIN= 3 = MAX3 / AVG MAX / AVG 2 AVG AVG2/ MIN / MIN MAX / MIN= MAX / MIN MAX MAX/ AVG / AVG MAX MAX/ MIN / MIN 4 11 14 13 9 7 5 3 = 3 = 2 === 4' 4' ▲ ▲ 2' 2' 3' 3' 4' 4' = = = == == 4' 5 12 13 11 8 7 5 4 3 2 = 2 In a continuing effort to offer the best product possible, we reserve the right to change, without notice, specifications or materials. Technical specification sheets that appear on 0' ceiling ceiling 0' www.zumtobel.us are the most recent version and supersede all 1' 1' other versions that exist in any other printed or electronic form. ttiioonn www.zumtobel.us 3' 1' 1' 2' 2' ▲ ▲ 06/27/13 3' 5 13 16 13 10 7 5 3 3 2 4'3' 3' 1' 2' 0'0' 0' 2' 3' 4' 5' 6' 7' 8' 9' floor Minimum 845-691-6262 800-932-0633 zli.us@zumtobel.com 1' 2'2' 1' 4 4 14 14 17 17 14 14 10 10 6 6 5 5 3 3 3 3 AVG2/ MIN= AVG2 / MIN = 2 Ceiling 1' 1' 1' 3' 2' 2' 2'3' 3' 3'4' 4' Wall 4'5' 5' 5'6' 6' 6'7' 7' 7'8' 8' 8'9' 9' Maximum = Maximum = 9' floor floor = = AverageAverage Floor Maximum Maximum 3' 3' 3' = MAX / AVG MAX / AVG MAX / MIN= MAX / MIN = = 17 = =8 Minimum Minimum = = Average = Average = =15 Maximum Minimum Minimum = =7= Average Zumtobel Lighting, Inc. ©2013 17-09 Zink Place, Unit 7 Fair Lawn, NJ 07410 3' ▲ ▲ 0.1 75 66 58 51 45 39 35 31 28 26 3' 0' 1' 0' 5 13 16 13 10 7 5 3 3 =2 ▲ 0.5 75 69 63 57 51 47 43 39 36 33 10' ▲ 0.1 78 68 59 51 45 40 35 32 29 26 Elevation 0.3 78 70 62 55 49 43 39 35 32 29 4 Minimum 0.3 0.3 72 65 58 52 47 42 38 34 31 29 Wall 0.7 78 74 69 64 59 55 51 48 44 42 22.3' Average Average Maximum= Minimum Minimum = Average ation EleWvall 0.1 80 69 60 52 45 40 36 32 29 26 8' ▲ ▲ 0.3 80 71 63 55 49 44 39 35 32 29 0.5 0.3 75 67 60 53 48 43 38 35 32 29 6 ▲ 0.7 80 75 70 65 60 56 52 49 45 42 0.7 0.5 78 72 65 59 53 48 44 40 37 34 17.8' ▲ 3' Effective Floor Cavity Reflectance = 20% 0.8 0.5 80 73 66 60 54 49 44 41 37 34 6' 1' 2' 3' Coefficients of Utilization pcc pw 0 1 2 3 4 5 6 7 8 9 10 ceiling ceiling Wall Average 45° 15411 13166 0 0 0 13.4' Wallwash Lighting Data Chart 3' Average 0° 4' ▲ Angle in Vertical° 23 Beam center footcandles shown in ''cone of light'' are initial, LLF = 1.0 Luminance Data in Candela / Sq. Meter 45° 55° 65° 75° 85° 8.9' ▲ 22.5° 500 0.0° 2' ▲ 45.0° 400 375 389 396 368 352 215 149 0 0 0 0 94 Elevation 300 0° 5° 15° 25° 35° 45° 55° 65° 75° 85° 90° 4.5' vatioonn EElleevati 67.5° 200 Horizontal Angle Zonal 0° Lumens Elevation 100 Vertical Angle Wall 90.0° Distance 3' 3' 4' 4'