Cut Sheet

advertisement
SPEC-5
Horizontal Compact Fluorescent
(1) 13W or 18W Quad Tube
Open Recessed
Downlight and Wallwasher
online
Find it Fast
Applications: This fixture offers
excellent brightness control in a 6"
aperture. Suitable for use in offices,
stores and lobbies, this recessed
downlight has a low profile that allows
it to be used in shallow plenum areas.
Available in two wattages with a
standard electronic ballast.
6"
114
Type:________________________________________
Project:______________________________________
____________________________________________
ORDERING NOTE: Complete unit consists of rough-in and trim section. Indicate ballast/voltage and desired options.
6202_____
S5D_____
BALLAST/VOLTAGE
ROUGH-IN
S5D6102
(1) 13W Quad Tube
S5D6103
(1) 18W Quad Tube
U Universal 120V/277V
S3 Dedicated 347V
LE1* LUTRON EcoSystem® (5%) 120V
LE2* LUTRON EcoSystem® (5%) 277V
AM1 ADVANCE® MARK VII® (5%) 120V
AM2 ADVANCE MARK VII (5%) 277V
AX1* ADVANCE® MARK X® (5%) 120V
AX2*ADVANCE MARK X (5%) 277V
TRIM
TRIM FINISH
6202R Downlight
Reflector
6202W Wallwasher
Reflector
6202K Corner
Wallwasher
6202DDouble
Wallwasher
* Available in 18W only.
Downlight
C
UL
®
S5D6103
shown
6 1/4"
6 3/4"
7 1/4"
Wallwasher
3. Mounting Brackets - Adjustable
butterfly mounting brackets allow for
a vertical adjustment of 2" and accept
one piece universal or C-channel
mounting bars (ordered as an optional
accessory).
US
LISTED
Suitable for damp locations
Fixtures with standby battery packs
are rated for dry locations only
Approved for thru-wiring
Above ceiling access not required
Thermally protected
IBEW Union Made
Alzak®is a registered trademark of the
Aluminum Company of America.
1. Yoke Assembly - 16 gauge steel
yoke assembly is corrosion protected
and fixed to the mounting pan.
2. Plaster Frame - 18 gauge
galvanized, die-formed plaster frame
has a fixed throat depth of 1".
4. Splice Compartment - 18 gauge
galvanized splice compartment is
U.L. listed for thru-wiring (4 in and 4
out at 90˚C) and has 7/8" knock-outs.
Ground wire is supplied. Splice compartment assembly is accessible from
below ceiling and is attached to the
yoke assembly by contractor.
5. Standby Battery Pack - IOTA
I-42, mounted on splice compartment
cover. An integral test light/switch,
supplied, is accessible and visible
through reflector aperture. Operates
on 120v or 277v, 60Hz only.
Zumtobel Lighting, Inc. ©2013
17-09 Zink Place, Unit 7
Fair Lawn, NJ 07410
845-691-6262
800-932-0633
zli.us@zumtobel.com
06/27/13
www.zumtobel.us
C Clear Specular
Reflector
MC Matte Clear
Alzak® Reflector
NOTE: Add “E” to
end of reflector
description for
standby fixture.
F* Fusing
W
White painted reflector flange
9930 Set of two 27" C-channel mounting bars
9952 Set of two 52" C-channel mounting bars
9956 Set of two 28" 10 ga. one piece
universal mounting bars
E4
Standby Battery Pack 120/277v
E4 is not available with 347V.
*Fusing not available with 347V.
12 1/4"*
10"
6 1/8"
6 1/8"
6 1/4"
6 3/4"
7 1/4"
OPTICS
S5D6103
shown
10"
12 9/16"
S5D6103 shown
*11 15/16” for
S5D6102
(Ceiling Opening = 6 3/4")
6. Reflector - One piece spun aluminum reflector with 1/2" flat flange
with low iridescence, specular clad
finish. Clear specular and matte clear
Alzak® finishes are available. A white
painted reflector flange is also available. The reflector is secured to the
yoke assembly by a center screw.
9. Ballast - One (1) lamp, thermally
protected Class P electronic ballast
is supplied.
7. Wallwasher Reflector - A
hydroformed aluminum kicker plate
is mounted to the main reflector
and is available in three specific
configurations for wall illumination.
Wallwasher reflector mounts in a
fixed orientation.
NOTE: National or municipal codes
must be followed regarding set back
of thermal insulating material from
fixture. As a guideline, any insulation
materials must be held away from the
fixture by a minimum of 3". Fixtures
are not designed for direct contact with thermal insulation.
8. Lamp/Socket - (1) 13W or 18W
quad tube compact fluorescent lamp
with a G24q-1 (13W) or a G24q-2
(18W) socket. Lamp supplied by
others.
In a continuing effort to offer the best product possible, we
reserve the right to change, without notice, specifications or
materials. Technical specification sheets that appear on
www.zumtobel.us are the most recent version and supersede all
other versions that exist in any other printed or electronic form.
EcoSystem ballast is wired to E1 & E2
(not dim hot) unless otherwise specified.
10. Weight - Housing - 4.6 lbs;
trim - .05 lbs.
Photometric Data
S5D6103 6202RC (1) 18W CFL
6" DOWNLIGHT, SPECULAR REFLECTOR
LTL 03061
Total Luminaire Efficiency 64%
0% Uplight
100% Downlight
Spacing Criteria
Lateral Plane
0°
90°
1.4
1.4
TOTAL LAMP LUMENS = 1250
INPUT WATTS = 20
Beam
Diameter
Candela Distribution
35.0
111.3
170.7
212.7
170.9
97.9
0.5
0.0
0.0
Average 90°
15411
13166
0
0
0
15411
13166
0
0
0
Wall
EcoSystem
(wired to E1 & E2 –
not dim hot)
unless otherwise specified
26.7'
3 FC
12'
0'
Ceiling
1'
1' 2'
2' 3'
3'
3' 4'
4'
4' 5'
5'
5' 6'
6'
6' 7'
7'
7' 8'
8'
8' 9'
9'
floor 9'floor
Floor
Maximum
=
Maximum
0.5
72
66
60
55
50
46
42
38
35
33
0.1
72
64
56
50
44
39
35
31
28
26
ceiling ceiling 0'
1' ceiling
1'
ceiling
2'
3'
4'
5'
6'
7'
8'
9'
floor
▲
2' 3'
4'
4'
0' 1'
5
12
13
11
8
7
5
4
3
= =2
2' 3'
1' 1'
3' 4'
4'
3' 3'
2' 2'3'
1'
2'
4
3
11
10
14
15
13
13
9
10
7
6
5
5
3
3
AVG
AVG / MIN / MIN=
3
=
MAX3 / AVG
MAX / AVG
2 AVG
AVG2/ MIN
/ MIN
MAX / MIN=
MAX / MIN
MAX
MAX/ AVG
/ AVG
MAX
MAX/ MIN
/ MIN
4
11
14
13
9
7
5
3
=
3
=
2 ===
4' 4'
▲
▲
2' 2'
3' 3'
4' 4'
=
=
=
==
==
4'
5
12
13
11
8
7
5
4
3
2
= 2
In a continuing effort to offer the best product possible, we
reserve the right to change, without notice, specifications or
materials. Technical specification sheets
that appear on 0'
ceiling
ceiling
0'
www.zumtobel.us are the most recent version and supersede all
1' 1'
other versions that exist in any other printed or electronic form.
ttiioonn
www.zumtobel.us
3'
1' 1'
2' 2'
▲
▲
06/27/13
3'
5
13
16
13
10
7
5
3
3
2
4'3'
3'
1' 2'
0'0' 0'
2'
3'
4'
5'
6'
7'
8'
9'
floor
Minimum
845-691-6262
800-932-0633
zli.us@zumtobel.com
1'
2'2'
1'
4
4
14
14
17
17
14
14
10
10
6
6
5
5
3
3
3
3
AVG2/ MIN=
AVG2 / MIN
= 2
Ceiling
1'
1' 1'
3'
2' 2'
2'3'
3'
3'4' 4'
Wall
4'5' 5'
5'6' 6'
6'7' 7'
7'8' 8'
8'9' 9'
Maximum
=
Maximum
= 9'
floor
floor
=
=
AverageAverage
Floor
Maximum
Maximum
3' 3'
3'
=
MAX / AVG
MAX / AVG
MAX / MIN=
MAX / MIN
=
= 17
= =8
Minimum
Minimum
=
=
Average
=
Average = =15
Maximum
Minimum
Minimum = =7=
Average
Zumtobel Lighting, Inc. ©2013
17-09 Zink Place, Unit 7
Fair Lawn, NJ 07410
3'
▲
▲
0.1
75
66
58
51
45
39
35
31
28
26
3'
0' 1'
0'
5
13
16
13
10
7
5
3
3
=2
▲
0.5
75
69
63
57
51
47
43
39
36
33
10'
▲
0.1
78
68
59
51
45
40
35
32
29
26
Elevation
0.3
78
70
62
55
49
43
39
35
32
29
4
Minimum
0.3
0.3
72
65
58
52
47
42
38
34
31
29
Wall
0.7
78
74
69
64
59
55
51
48
44
42
22.3'
Average
Average
Maximum=
Minimum
Minimum
=
Average
ation
EleWvall
0.1
80
69
60
52
45
40
36
32
29
26
8'
▲
▲
0.3
80
71
63
55
49
44
39
35
32
29
0.5
0.3
75
67
60
53
48
43
38
35
32
29
6
▲
0.7
80
75
70
65
60
56
52
49
45
42
0.7
0.5
78
72
65
59
53
48
44
40
37
34
17.8'
▲
3'
Effective Floor Cavity Reflectance = 20%
0.8
0.5
80
73
66
60
54
49
44
41
37
34
6'
1'
2'
3'
Coefficients of Utilization
pcc
pw
0
1
2
3
4
5
6
7
8
9
10
ceiling ceiling
Wall
Average 45°
15411
13166
0
0
0
13.4'
Wallwash Lighting Data Chart
3'
Average 0°
4'
▲
Angle in Vertical°
23
Beam center footcandles shown in
''cone of light'' are initial, LLF = 1.0
Luminance Data in Candela / Sq. Meter
45°
55°
65°
75°
85°
8.9'
▲
22.5°
500
0.0°
2'
▲
45.0°
400
375
389
396
368
352
215
149
0
0
0
0
94
Elevation
300
0°
5°
15°
25°
35°
45°
55°
65°
75°
85°
90°
4.5'
vatioonn
EElleevati
67.5°
200
Horizontal Angle
Zonal
0°
Lumens
Elevation
100
Vertical
Angle
Wall
90.0°
Distance
3' 3'
4' 4'
Download