J6.1.8.2 T4 METAL HALIDE MULTI-SPOTS® PRODUCT SPECIFICATIONS Lamp: One, two or three T4 metal halide lamps. Lamp Holder: T4/T4.5 – G8.5 bi-pin socket base with recessed female contacts • 1A, 750V, rated for 5KV pulse • T4 Mini – Twist and lock GU6.5 base; 2A, 250V rated for 5KV pulse • BT5 – Twist and lock PGJ5 base; 2A, 250V rated for 2.5KV pulse. Lamp Housing Integral accessory holder and metal snoot for improved lamp shielding • Can be combined with accessory louver and/or accessory color filters. Multi-Lamp Recessed Adjustables, Ceramic Arc Tube 20/39/70W T4/T4.5, 20/39W T4 Mini, 20/39W BT5 MST4, MSTM, MSBT ELECTRONIC BALLAST Aiming 45˚ vertical aiming capability and 360˚ horizontal rotation • Each lampholder is individually aimable. Trim Finish All black with white flange (BL) or all white with white lamp cartridge and white flange (WH). Electronic Ballast Premium, high efficiency, constant power electronic ballast provides optimum color and CRI uniformity from fixture to fixture • Offers most consistent lumen output and photometric performance over life of lamp • Controlled starting current and stable normal operation maximizes lamp life • Faster hot restrike and lamp warm-up time compared to magnetic ballast • Automatic resetting thermal protection • MOV transient protection • End-of-life shutdown prevents nuisance cycling and flashing • May be replaced from above or below ceiling • T4/T4.5 and T4 Mini – Universal 120/277 volt electronic solid state, high power factor and reliable starting to -30˚C • BT5 – 120 volt electronic solid state, high power factor and reliable starting to -20˚C. Type Cat. No. _____________________________________ _____________________________________ Project:_________________________________________ Notes: _________________________________________ DIMENSIONS Lamp Guard Clear tempered glass. Labels UL/C-UL listed for through-branch wiring, damp locations, and IP • Product thermally protected against improper use of lamps or insulation • I.B.E.W. Union made • CSA certified. 11" 9 5/8" 6 3/4" Product specifications subject to change without notice. INSTALLATION Mounting Bracket Mounting brackets have 2.5” vertical adjustment and accept proprietary Tru-Lock bar hangers, 1 1/2” C-channel and flat linear bars (ordered as accessories) or 1/2” EMT, 3/4” and 1 1/2” C-channel (by others) • One-piece Tru-Lock bar hangers have integral T-bar locking screws and alignment notches for locating and locking fixture in the center or 1/4 tile increments. 9 1/2" 8 5/8" Ceiling Cutout 6 3/4" Housing 22 gauge die-formed galvanized steel, vented • Electrical connections can be made from below the ceiling in an internal wireway or from above the ceiling through a wireway access cover • Wireway access cover has (2) 1/2” knockouts with pry-out slot for conduit attachment • 1/2” knockouts with pry-out slots are located on each end of fixture for conduit attachment or continuous row, end-to-end fixture installation. 23 5/8" 14 5/8" 9 1/2" 8 1/2" Ceiling Cutout 8 1/2" Ceiling Cutout Trim Attaches to housing using torsion springs • Lamps are replaced by removing lampholder insert/snoot assembly for easy front relamping. Accessories Up to three accessories may be used simultaneously in each lampholder including the optional snoot. 8 1/2" Ceiling Cutout 8 1/2" 13 5/8" Dia. Ceiling Cutout 22 5/8" Dia. Ceiling Cutout ORDERING INFORMATION: Rough-in and accessories ordered separately. Example: MSBT-SS-20H1-BL Example: HB-TL Beam Spread/ One per Lamp 1 2 3 Rough-In - Wattage/Lamp - S Spot N Narrow Flood F Flood Finish - 20H WH White (T4 Mini, T4/T4.5) BLBlack 20W 120V/277V Electronic Note: Only use one 20H1 1 beam spread designaMSTM (BT5 only) tions for 1-lamp unit. T4 Mini MH 20W 120V Electronic Lamp GU6.5 (see example below) 39H base (T4 Mini, T4/T4.5 only) Note: Only use two 39W 120/277V Electronic 2 beam spread designaMSBT 39H1 tions for 2-lamp units. BT5 MH (BT5 only) (see example below) Lamp 39W 120V Electronic PGJ5 base 39H2 (BT5 only) 39W 277V Electronic 70H 1 GE SuperMini T4 (T4/T4.5 only) 2 Philips Mini MasterColor® CDM-Tm 70W 120/277V Electronic MST4 T4/T4.5 MH Lamp G8.5 base Ordering Example: 1-Lamp Unit; MSBT-S-20H1-BL 2-Lamp Unit; MSBT-SS-20H1-BL 3-Lamp Unit; MSBT-FSF-20H1-BL 1/10 Options Accessories †347 347 Volt ***F Fuse and Fuse Holder (Where *** = voltage) †CP Chicago Plenum † Consult Factory for Availability HB-TL HB-28 HB-52 LB-27 Two Two Two Two 25” 28” 52” 27” Tru-Lock Bar Hangers, Pair C-channel Bar Hangers, Pair C-channel Bar Hangers, Pair Linear Bar Hangers, Pair T569BL T561 T562 T563 T564 T565 T566 T5677 T5678 T5621 T5619 T5622 Louver-3 3/4” Dia. with 1/2 Sq. Cells Med. Pink Color Filter Warm Red Color Filter Daylite Blue Color Filter Med. Blue Color Filter Med. Amber Color Filter Med. Green Color Filter Prismatic Spread Lens Linear Spread Lens Uniformity Lens Color Correction Lens/UV Filter UV Filter 1300 South Wolf Road • Des Plaines, Illinois 60018 PHONE 800-367-5866 • FAX 888-708-6578 www.junolightinggroup.com J6.1.8.2 T4 METAL HALIDE MULTI-SPOTS® Multi-Lamp Recessed Adjustables, Ceramic Arc Tube 20/39/70W T4/T4.5, 20/39W T4 Mini, 20W BT5 MST4, MSTM, MSBT ELECTRONIC BALLAST ENGINEERING DATA 20W 39W 70W ANSI # M156 M-130 M-98/M-139/M-143 Input Voltage 120V 277V 120V 277V 120V 277V Input Current 0.22A 0.10A 0.39A 0.18A 0.67A 0.29A Input Power 26W 46W 78W Power Factor >0.90 >0.90 >0.90 Lamp Current Crest Factor <1.2 Typ. <1.2 Typ. <1.2 Typ. Ballast Factor 1.0 Typ. 1.0 Typ. 1.0 Typ. T.H.D. <15%<15% <15% Max. Recommended Ambient Operating Temperature 40˚ C 40˚ C 40˚ C EMI FCC Part 18 Class A FCC Part 18 Class A FCC Part 18 Class A Sound Rating A AA FOR HORIZONTAL AIMING ANGLES MH W Aim Point A 0ϒ Aiming Angle (A = 0ϒ) W Aim Point L L Aiming Angle (A = 30ϒ) FOR VERTICAL AIMING ANGLES FOR HORIZONTAL AIMING ANGLES D X MH W Aim Point A 0ϒ Aim Point L L Aiming Angle (A = 0ϒ) CBCP • Centerbeam candlepower FC • Footcandles at beam center (aim point) L Aiming Angle (A = 30ϒ) Vertical Aiming Angles D X A 0ϒ 0° Lamp Aim Point W FOR VERTICAL AIMING ANGLES Horizontal Aiming Angles In vertical aiming applications, aim point (X) is determined by dividing distance from the wall (D) by the tangent of the desired aim angle (A) (0.5774 for 30˚, 1.0 for 45˚). A 0ϒ W Aim Point L W 30° Beam Beam Rated TypeSpread° Life CBCPMHFC LWFC LW 30° 45° DFC X LWFC X L W 1.7 1.7326 2.2 1.9 2.0 2.0227 2.7 2.3 2.4 2.4166 3.1 2.7 2.7 2.7127 3.6 3.1 3.0 3.0101 4.0 3.5 4392 6.92.71.311104.01.41.0 617410.44.12.04936.02.01.4 8 9813.95.52.72778.02.71.9 106317.36.93.4178 10.03.42.4 124420.88.24.0123 12.04.12.9 NFL 1000014462 8226 3.8 3.8147 5.2 4.4 27° 10145 4.8 4.8 94 6.5 5.5 12100 5.8 5.8 65 7.8 6.7 14746.76.7489.17.8 16567.77.737 10.48.9 2452 3.54.61.912782.02.01.4 4113 6.99.33.83204.04.12.7 6 5010.4 13.95.81426.06.14.1 8 2813.91.67.7 808.08.25.4 10 18 17.3 23.2 9.6 5110.0 10.2 6.8 FL 40° 10000 8833 8138 5.8 5.8 90 8.1 6.7 10887.27.257 10.18.4 12618.78.740 12.1 10.0 1445 10.1 10.129 14.1 11.7 1635 11.6 11.622 16.2 13.4 2276 3.59.52.97812.03.32.0 3123 5.2 14.34.33473.05.03.1 4 69 6.9 19.15.81954.06.74.1 5 44 8.7 23.97.21255.08.35.1 6 31 10.4 **8.7 87 6.010.0 6.1 70W T4 G8.5 SP 10° 1000050218 Ceramic Metal Halide For 39W lamps use 0.55 multiplier. For 20W lamps use 0.28 multiplier. 10502 12349 14256 16196 18155 The beam spread in degrees and the beam “L” and “W” in the above tables are computed at 50% of centerbeam candlepower and represent areas of “effective illumination.” **Due to steep aiming angle, length of beam extends beyond 25’. 1300 S. Wolf Road • Des Plaines, IL 60018 • Phone (800) 367-5866 • Fax (888) 708-6578 Visit us at www.junolightinggroup.com Printed in U.S.A. ©2016 Acuity Brands Lighting, Inc.