Surge Protective device OEM ODM Professional Manufacturer www.thorspd.com All Program Lightning Protection Systems Company profile Wenzhou Tuoer Electric Co., Ltd. is a professional enterprise specialized in producing surge protectors. Our company is located in Liushi. Our company currently provides up to 60 kinds of surge protectors. We also provide surge protectors according to customers' requirements. With strict management, standardized production workshops, advanced ERP management system, efficient workers, and professional technical personnel, we are providing customers with high quality and cheap products. We welcome the friends from all over the world to negotiate with us for the cooperation and development of lightning over-voltage protection market. Our goals: To become a professional company of designing and manufacturing over-voltage protection products and lightning products Certificate CE ISO9001 TEST REPROT Work Theory In there-phase-four-wire system. There are protective devices between the wires and the land. Normally, protective device is high resistance When urban network is struck by lightning or others high pulse voltage. SPD will convey the surge voltage into the earth in ns level. So the equipments are protected. When surge voltage passes the SPD and disappears. The SPD return to high resistance. It won't effect network's normal operation. Technical Data: ■ Frequency:50~60Hz ■ Max continuous operating voltage Uc(V) 140,275,320,385,440 ■ Discharge current □ Nominal discharge current In(kA):5,8,10,20,30,40,50,60,80 □ Max discharge current Imax(kA):10,15,20,40,60,80,100,120,150 ■ Voltage protection level Up:1.0 1.2 1.5 1.8 2.0 2.5 3.0 4.0 ■ When the Surge Protector has reach to the Maximum continuous operating voltage Uc ,Then the leakage current Ic is: □ 1P/4P:<800μA □ 1P+N/3P+N:0μA ■ Through the window of mechanical instructions that display the working stste □ Green or white:Normal working condition □ Red:Replaceable parts must be replaced ■ Connection port allows the cross-sectional area □ Copper conductor:2.5~36mm2 ■ Environment temperate:-25℃--+60℃ ■ Conserve temperate:-40℃--+70℃ ■ Protective level:IP 20 ■ Reference weight(g) □ 1P:90 □ 1P+N:180 □ 4P:390 □ 3P+N:420 ■ Complies with the standards □ IEC 61643-11/Ⅱtest ■ Distant instruction contacts □ Electrical parameters DC:12V,≥10mA AC250V,≤1A □ Cross-sectional area:0.5~1.5mm2 Type definition Protective level B,C,D Design serial number Combinations 1P,2P,3P 4P,3P+N Rated voltage Uc Max discharge current(kA) Annex : XDistance instuction contacts TRS1-C / Overall structure TRS system SPD using modular design,35mm electrial trail mount,90mm product width,Thickness into three kinds:18mm 27mm 36mm. Mounting SPD adopts standard 35mmtrail to mount; SPD adopts 4-35mm2 copper wire to connect, and has two ways; From the power switch to SPD , then from SPD to the load .In this way, it is suitable the distribution box of loading not over 100A.,The section should base on the current of the load。 From the power switch to SPD . Then from power switch to the load . In this way . It is suitable the distribution box of loading over 100A. The section should not longer than 500mm The earthed wire is adopted over 4mm2 double color wrie. And not longer than500mm。 The L wire, connected the protector should have a fuse of 10-32A. To make sure the network working normally . And avoid of the SPD disabled。 In this way . Please adopt the folowing section to connect: Class B:Over Imax 60kA phase wire>16mm2 earthed wire>25mm2 Class C:Over Imax 40kA phase wrie>10mm2 earthed wire>16mm2 Class D: Below Imax 20kA phase wire >6mm2 earthed wire>10mm2 Using and maintenance After demanding mounting . Need not to adjust ; It can protect the network automatically after the SPD mounted rightly; It sgould check the mark of the module red or not , and lamp of the fuse is light or not . And change the disabled components immediately Order When ordering, Indicating type, quantity should be marked 。For example:TRS1-C/4-420-40 100PCS To meet special specification should contact us When the goods are packed with product has the folowing ducuments: Product certification(each group) instruction (each group) Packing list(each package) AC Surge Protection Device Parameter list could be developed Discharge current Noted:●Already have or can be chosen. In-Imax(kA) TRS1-D TRS1-C TRS1-B TRS2 TRS4 TRS5 TRS6 TRS7 TRS9 ● ● ● ● ● ● ● ● ● 60-120 ● ● 80-150 ● ● TRS7 TRS9 ● ● TRS7 TRS9 5-10 ● ● ● 10-20 ● ● ● 15-30 ● ● ● ● ● ● ● 20-40 ● 30-60 ● 40-80 ● ● 50-100 Width Noted:●Already have or can be chosen. 1P/4P(mm) TRS1-D TRS1-C TRS1-B 18/72 ● ● 27/108 TRS2 TRS4 TRS5 ● ● ● ● TRS6 ● 36/144 Others Noted:● Already have or can be chosen. Named TRS1-D TRS1-C TRS1-B TRS2 TRS4 TRS5 TRS6 Replaceable module ● ● ● ● ● ● ● Working instructions ● ● ● ● ● ● ● ● ● Distance instruction contacts ● ● ● ● ● ● ● ● ● TRS2 TRS4 TRS5 TRS6 TRS7 TRS9 Composite type Noted:●Already have or can be chosen. In-Imax(kA) TRS1-D TRS1-C TRS1-B 1P ● ● ● ● ● ● ● ● ● 2P ● ● ● ● ● ● ● ● ● 3P ● ● ● ● ● ● ● ● ● 4P ● ● ● ● ● ● ● ● ● 1P+NPE ● ● ● ● ● ● ● ● ● 3P+NPE ● ● ● ● ● ● ● ● ● TRS1-D AC Surge Protection Device Application: TRS1-D AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS1D/□-140 TRS1D/□-275 TRS1D/□-320 TRS1D/□-385 TRS1D/□-440 140 275 320 385 440 IEC category II Nominal discharge current (In)(8/20μS) (KA) 5/10/15 5/10/15 5/10/15 5/10/15 5/10/15 Max discharge current (8/20μS)(Imax): (KA) 10/20/30 10/20/30 10/20/30 10/20/30 10/20/30 Voltage protection level (UP)(KV) <0.8kV <1.2kV <1.5kV <1.8kV <1.8kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ yellow Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS1-C AC Surge Protection Device Application: TRS1-C AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS1-C/□275 275 TRS1-C/□320 TRS1-C/□385 320 IEC category TRS1-C/□440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 20 20 20 20 Max discharge current (8/20μS)(Imax): (KA) 40 40 40 40 Voltage protection level (UP)(KV) <1.2kV <1.5kV <1.8kV <2.0kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Gray Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS1-B AC Surge Protection Device Application: TRS1-B AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS1-B/□275 275 TRS1-B/□320 TRS1-B/□385 320 IEC category TRS1-B/□440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 30/40 30/40 30/40 30/40 Max discharge current (8/20μS)(Imax): (KA) 60/80 60/80 60/80 60/80 Voltage protection level (UP)(KV) <1.5kV <1.8kV <2.0kV <2.5kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Red Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS2 AC Surge Protection Device Application: TRS2 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS2/□-275 275 TRS2/□-320 TRS2/□-385 320 IEC category TRS2/□-440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 15/20/30 15/20/30 15/20/30 15/20/30 Max discharge current (8/20μS)(Imax): (KA) 30/40/60 30/40/60 30/40/60 30/40/60 Voltage protection level (UP)(KV) <1.5kV <1.8kV <2.0kV <2.5kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Gray Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS4 AC Surge Protection Device Application: TRS4 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS4/□140 140 TRS4/□275 275 IEC category TRS4/□320 TRS4/□385 320 TRS4/□440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 Max discharge current (8/20μS)(Imax): (KA) 10/20/30 /40 10/20/30 /40 10/20/30 /40 10/20/30 /40 10/20/30 /40 Voltage protection level (UP)(KV) <0.8kV <1.2kV <1.5kV <1.8kV <2.0kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Red/Black Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS5 AC Surge Protection Device Application: TRS5 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS4/□140 140 TRS4/□275 275 IEC category TRS4/□320 TRS4/□385 320 TRS4/□440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 5/10/15/ 20 Max discharge current (8/20μS)(Imax): (KA) 10/20/30 /40 10/20/30 /40 10/20/30 /40 10/20/30 /40 10/20/30 /40 Voltage protection level (UP)(KV) <0.8kV <1.2kV <1.5kV <1.8kV <2.0kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Red/Gray Strengthen fire resistance PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS6 AC Surge Protection Device Application: TRS6 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS6/□-275 275 TRS6/□-320 320 IEC category TRS6 (convex) TRS6/□-440 385 440 II Nominal discharge current (In)(8/20μS) (KA) 30/40/80 30/40/80 30/40/80 30/40/80 Max discharge current (8/20μS)(Imax): (KA) 60/80/100 60/80/100 60/80/100 60/80/100 Voltage protection level (UP)(KV) <1.5kV <1.8kV <2.0kV <2.5kV Response time (ns) Degree of protection TRS6 (flat) TRS6/□-385 Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Gray Strengthen fire resistance PC PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS7 AC Surge Protection Device Application: TRS7 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS7/□-320 320 TRS7/□-385 TRS7/□-440 385 TRS7/□-660 440 IEC category 660 II Nominal discharge current 30/40/50/80 30/40/50/80 30/40/50/80 30/40/50/80 (In)(8/20μS) (KA) Max discharge current (8/20μS)(Imax): (KA) 60/80/100/ 150 60/80/100/ 150 60/80/100/ 150 60/80/100/ 150 Voltage protection level (UP)(KV) <2.0kV <2.5kV <3.0kV <3.5kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Gray Strengthen fire resistance PC PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRS9 AC Surge Protection Device Application: TRS9 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998 Technical Data Type Max continuous operating voltage (UC):(V) TRS9/□-320 320 TRS9/□-385 TRS9/□-440 385 TRS9/□-660 440 IEC category 660 II Nominal discharge current 30/40/50/80 30/40/50/80 30/40/50/80 30/40/50/80 (In)(8/20μS) (KA) Max discharge current (8/20μS)(Imax): (KA) 60/80/100/ 150 60/80/100/ 150 60/80/100/ 150 60/80/100/ 150 Voltage protection level (UP)(KV) <2.0kV <2.5kV <3.0kV <3.5kV Response time (ns) Degree of protection Operating temp range Color Frame material Cross section area ≤25ns IP20 -40℃--+80℃ Red Black Strengthen fire resistance PC PBT Phase wire :6-35mm2 Earthed wire:6-35mm2 Remote sig terminal: 1.5mm2 Accessonies Addtion remote signal control TRSS-RJ45 Data Line Surge Protection Application TRSS-RJ45 Multi-Connection signal surge arrester used for protecting Ethernet 100 Base-Y/TX . LAN and 10 Base -T(IEEE802.5) from damage for inductive thunderbolt electric wave , surge and atatic interference Technical data TRSS-RJ45 Type Nominal voltage Un(V) 5V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 60V line-PE 250V Max transfer speed 100MB/S Response time (ns) 1ns Connection inpotout put RJ45 Pinning 1/2,3/6, 1-8 TRSS-RJ45-24 Data Line Surge Protection Application TRSS-BNC-24 multi-connection net signal surge arrester . used for protecting Ethernet 100 BASE T/TX . 100Vg-Any-LAN ,CDDI . OBASE-TIEEE802. EURO-ISDN etc . Like HUB from damage for inductive thunder bolt electric wave . surge and static interference Technical data TRSS-RJ45-24 Type Nominal voltage Un(V) 5V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 60V line-PE 250V Max transfer speed 100MB/S Response time (ns) 1ns Connection inpotout put Pinning RJ45 1/2,3/6, 1-8 TRSS-RJ11 Data Line Surge Protection Application TRSS-RJ11 signal surge arrester for public switched telephone network system ,ect. It is used to protect the indirect thunder influence or other instantaneous over voltage surge Technical data Type TRSS-RJ11 Nominal voltage Un(V) ≤180V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 250V line-PE 250V Max transfer speed 2MB/S Response time (ns) 1ns Connection inpotout put RJ11 Pinning 3/4 TRSS-485 Data Line Surge Protection Application TRSS-485 signal control surge arrester for transporting analog signals and controlling system like: supervisory control system, communication system, PLC , MCR ,etc.Possessing low limiting voltage with high discharging capablity . It is used to protect the indirect thunder influence or other instantaneous over voltage surge Technical data Type TRSS-485 Nominal voltage Un(V) 24V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 65V line-PE 65V Max transfer speed 2MB/S Response time (ns) 1ns Connection inpotout put CH 3.96terminal TRSS-BNC Data Line Surge Protection Application TRSS-BNC is coaxial signal surge arrester for coaxial computer system like: 100 Base-2 , video and camera system, etc. it is used to protect the indirect thunder influence or other instantaneous over-voltage surge Technical data TRSS-BNC Type Nominal voltage Un(V) 5V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 25V line-PE 600V Max transfer speed 16MB/S Bestwith fo ≥20MHZ Imax ≤0.3db loss Test socket connection loss Connection inpotout put ≥20db BNC TRSS-BNC-24 Data Line Surge Protection Application TRSS-BNC-24 multi-connection net signal surge arrester . used for protecting Ethernet 100 BASE T/TX . 100Vg-Any-LAN ,CDDI . OBASE-TIEEE802.3 EURO-ISDN etc . Like HUB from damage for inductive thunder bolt electric wave . surge and static interference Technical data TRSS-BNC-24 Type Nominal voltage Un(V) 5V Nominal discharge current(In)(8/20μS) 5kA Voltage protection level (UP): line-line 25V line-PE 600V Max transfer speed 16MB/S Bestwith fo ≥20MHZ Imax loss ≤0.3db Test socket connection loss ≥20db Connection inpotout put BNC TRSS-BNC+2 Application TRSS-BNC +2 surge arrester is mainly used for supervisory control system . preventing product form Lightning strike and surge possessing three kinds of production for single-phase AC power source 24V 36V 48V and video signal Technical data AC Power Source Protection Class III/C Mode of connection In series Nominal voltage(Un) 220V AC Voltage protection level(Up) 1800V Max discharge current(In)(8/20μS) 10KA 485 Signal control Nominal voltage Un(V) 24V DC Voltage protection level(Up) 60V Max discharge current(In)(8/20μS) 5KA Video signal Connection inputout put BNC Nominal voltage Un(V) 24V DC Voltage protection level Lineline/line-PG(Up) 65V/300V Max discharge current(In)(8/20μS) 5KA Max transfer speed 20M VSWR <1.2 Insertion loss <0.2dB TRSS-DB Data Line Surge Protection Technical data Type TRSS-DB25 Connection and pinning L:2/3 SG7 PGl 12 18 L:2/3/ 4/5 /6/8/20 Sg7 PG1 12 18 TRSS-DB25 TRSS-DB15 L:2/3 SG5 TRSS-DB9 PG1 TRSS-DB9 Un(V) Uc(V) Isn(8/2 transport Note 5692a 0μS) speed≤bits 92a ≤KA 12 18 L:2/9/4/1 SG8 PG1 8 15 L:1/2/3/4/6/ 7/8/9 SG5 PG 12 18 5 1M 5 1M RS232 RS422 SDLC RS423 RS485 HDLC TRSS-W Coaxial surge arrester series Technical data Type Gas tube discharge connection BNC Frequency band (MHz) 0--2000 0--1500 0--2000 0--1500 0--1500 0--1500 0--1500 Max continuous voltage(Uc)(V) BNC F <1.2 Insertion loss <0.2 Max power Response time (ns) TNC UHF DIN7/1 6 DC68/AC130V/AC280V VSWR impedance N 75 50 75 300W 1ns 50 500W 50 50 50 TRSB Lightning Rod Protection Carachteristic&Benefits 1) 100% of efficacy in discharge capture 2) high level of protection 3) Electric continuity guaranteed The device does not offer any resistance to discharge conduction 4) Lightning rod without electrical components , maxim durability guaranteed. 5) It does not need external power supply TYPE TRSB-1/3.1 TRSB-1/3.3 TRSB-1/4.3 TRSB-1/5.3 TRSB-1/6.3 TRSL Socket surge arrester Application TRSL Socket surge arrester series is used for protecting electronic equipment from damage for inductve thunderbolt electric wave, surge and static interference Technical date Max continuous operating voltage (UC)(V) 275V/320V/385V-50Hz 60Hz Nominal discharge current(In)(8/20μS) 5KA 8KA Max discharge current (8/20us)(Imax) 8KA 15KA Voltage protection level (UP): 1.0KV/1.2KV/1.5KV Response time (ns) ≤2.5ns Operating temp -40℃--+80℃ TRS230 DC surge arrester series Application: DC surge arrester series used for protecting supervisory control system and 24V dc control from damage for inductive thunderbolt electric wave, surge and static interference Technical date Nominal operating voltage Un TRS230-12 TRS2302-4 TRS230-36 TRS230-48 Nominal operating voltage Un 12V DC 24V DC 36V DC 48V DC Voltage protection level(Up) 40V 60V 80V 110V Max discharge current (8/20μS)(Imax): (Isn) 5kA 5kA 5kA 5kA TRSX power supply arrester series Application: TRSX power supply arrester series is used for three- phase power supply system, The protective device sort is class B. connected parallel in power supply system, preventing from damage for inductive thunderbolt electric wave , surge and static interference Technical date Type TRSX-20 TRSX-40 Nominal operating voltage Un AC380V Max continuous voltage(Uc)(V) AC440V TRSX-80 TRSX-60 TRSX-100 20 Max discharge current(In)(8/2 0μS) 40 60 80 100 Nominal discharge 10 current(In)(8/2 0μS) 20 30 40 50 Response time (ns) Voltage protection level(8/20μS3KA )Up(V) Protection mode Connection way Remote signal control Frequency Operating temp ≤2.5ns ≤800 ≤1000 ≤1200 L1/L2/L3-N ≤1500 N-PE In parallel Yes 47--63Hz -40℃--+85℃ ≤2000