Surge Protective device

advertisement
Surge Protective device
OEM ODM Professional Manufacturer
www.thorspd.com
All Program Lightning Protection Systems
Company profile
Wenzhou Tuoer Electric Co., Ltd. is a professional enterprise specialized in producing surge protectors. Our company is
located in Liushi.
Our company currently provides up to 60 kinds of surge protectors. We also provide surge protectors according to
customers' requirements.
With strict management, standardized production workshops, advanced ERP management system, efficient workers,
and professional technical personnel, we are providing customers with high quality and cheap products.
We welcome the friends from all over the world to negotiate with us for the cooperation and development of lightning
over-voltage protection market.
Our goals:
To become a professional company of designing and manufacturing over-voltage protection products and lightning
products
Certificate
CE
ISO9001
TEST REPROT
Work Theory
In there-phase-four-wire system. There are protective devices between the wires and the land. Normally, protective
device is high resistance
When urban network is struck by lightning or others high pulse voltage. SPD will convey the surge voltage into the
earth in ns level. So the equipments are protected. When surge voltage passes the SPD and disappears. The SPD return
to high resistance. It won't effect network's normal operation.
Technical Data:
■ Frequency:50~60Hz
■ Max continuous operating voltage
Uc(V)
140,275,320,385,440
■ Discharge current
□ Nominal discharge current
In(kA):5,8,10,20,30,40,50,60,80
□ Max discharge current
Imax(kA):10,15,20,40,60,80,100,120,150
■ Voltage protection level
Up:1.0 1.2 1.5 1.8 2.0 2.5 3.0 4.0
■ When the Surge Protector has reach to the Maximum continuous operating voltage Uc ,Then the leakage current Ic
is:
□ 1P/4P:<800μA
□ 1P+N/3P+N:0μA
■ Through the window of mechanical instructions that display the working stste
□ Green or white:Normal working condition
□ Red:Replaceable parts must be replaced
■ Connection port allows the cross-sectional area
□ Copper conductor:2.5~36mm2
■ Environment temperate:-25℃--+60℃
■ Conserve temperate:-40℃--+70℃
■ Protective level:IP 20
■ Reference weight(g)
□ 1P:90
□ 1P+N:180
□ 4P:390
□ 3P+N:420
■ Complies with the standards
□ IEC 61643-11/Ⅱtest
■ Distant instruction contacts
□ Electrical parameters
DC:12V,≥10mA
AC250V,≤1A
□ Cross-sectional area:0.5~1.5mm2
Type definition
Protective
level
B,C,D
Design
serial
number
Combinations
1P,2P,3P
4P,3P+N
Rated
voltage
Uc
Max
discharge
current(kA)
Annex :
XDistance
instuction contacts
TRS1-C /
Overall structure
TRS system SPD using modular design,35mm electrial trail mount,90mm product width,Thickness into three
kinds:18mm
27mm 36mm.
Mounting
SPD adopts standard 35mmtrail to mount;
SPD adopts 4-35mm2 copper wire to connect, and has two ways;
From the power switch to SPD , then from SPD to the load .In this way, it is suitable the distribution box of loading not
over 100A.,The section should base on the current of the load。
From the power switch to SPD . Then from power switch to the load . In this way . It is suitable the distribution box of
loading over 100A. The section should not longer than 500mm
The earthed wire is adopted over 4mm2 double color wrie. And not longer than500mm。
The L wire, connected the protector should have a fuse of 10-32A. To make sure the network working normally . And
avoid of the SPD disabled。
In this way . Please adopt the folowing section to connect:
Class B:Over Imax 60kA phase wire>16mm2 earthed wire>25mm2
Class C:Over Imax 40kA phase wrie>10mm2 earthed wire>16mm2
Class D: Below Imax 20kA phase wire >6mm2 earthed wire>10mm2
Using and maintenance
After demanding mounting . Need not to adjust ;
It can protect the network automatically after the SPD mounted rightly;
It sgould check the mark of the module red or not , and lamp of the fuse is light or not . And change the disabled
components immediately
Order
When ordering, Indicating type, quantity should be marked 。For example:TRS1-C/4-420-40 100PCS
To meet special specification should contact us
When the goods are packed with product has the folowing ducuments:
Product certification(each group)
instruction (each group)
Packing list(each package)
AC Surge Protection Device Parameter list could be developed
Discharge current
Noted:●Already have or can be chosen.
In-Imax(kA)
TRS1-D TRS1-C TRS1-B
TRS2
TRS4
TRS5
TRS6
TRS7
TRS9
●
●
●
●
●
●
●
●
●
60-120
●
●
80-150
●
●
TRS7
TRS9
●
●
TRS7
TRS9
5-10
●
●
●
10-20
●
●
●
15-30
●
●
●
●
●
●
●
20-40
●
30-60
●
40-80
●
●
50-100
Width
Noted:●Already have or can be chosen.
1P/4P(mm)
TRS1-D TRS1-C TRS1-B
18/72
●
●
27/108
TRS2
TRS4
TRS5
●
●
●
●
TRS6
●
36/144
Others
Noted:● Already have or can be chosen.
Named
TRS1-D TRS1-C TRS1-B
TRS2
TRS4
TRS5
TRS6
Replaceable module
●
●
●
●
●
●
●
Working instructions
●
●
●
●
●
●
●
●
●
Distance instruction
contacts
●
●
●
●
●
●
●
●
●
TRS2
TRS4
TRS5
TRS6
TRS7
TRS9
Composite type
Noted:●Already have or can be chosen.
In-Imax(kA)
TRS1-D TRS1-C TRS1-B
1P
●
●
●
●
●
●
●
●
●
2P
●
●
●
●
●
●
●
●
●
3P
●
●
●
●
●
●
●
●
●
4P
●
●
●
●
●
●
●
●
●
1P+NPE
●
●
●
●
●
●
●
●
●
3P+NPE
●
●
●
●
●
●
●
●
●
TRS1-D AC Surge Protection Device
Application:
TRS1-D AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS1D/□-140
TRS1D/□-275
TRS1D/□-320
TRS1D/□-385
TRS1D/□-440
140
275
320
385
440
IEC category
II
Nominal discharge
current
(In)(8/20μS)
(KA)
5/10/15
5/10/15
5/10/15
5/10/15
5/10/15
Max discharge
current
(8/20μS)(Imax):
(KA)
10/20/30
10/20/30
10/20/30
10/20/30
10/20/30
Voltage protection
level (UP)(KV)
<0.8kV
<1.2kV
<1.5kV
<1.8kV
<1.8kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
yellow
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS1-C AC Surge Protection Device
Application:
TRS1-C AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS1-C/□275
275
TRS1-C/□320
TRS1-C/□385
320
IEC category
TRS1-C/□440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
20
20
20
20
Max discharge
current
(8/20μS)(Imax):
(KA)
40
40
40
40
Voltage protection
level (UP)(KV)
<1.2kV
<1.5kV
<1.8kV
<2.0kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Gray
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS1-B AC Surge Protection Device
Application:
TRS1-B AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS1-B/□275
275
TRS1-B/□320
TRS1-B/□385
320
IEC category
TRS1-B/□440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
30/40
30/40
30/40
30/40
Max discharge
current
(8/20μS)(Imax):
(KA)
60/80
60/80
60/80
60/80
Voltage protection
level (UP)(KV)
<1.5kV
<1.8kV
<2.0kV
<2.5kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Red
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS2 AC Surge Protection Device
Application:
TRS2 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS2/□-275
275
TRS2/□-320
TRS2/□-385
320
IEC category
TRS2/□-440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
15/20/30
15/20/30
15/20/30
15/20/30
Max discharge
current
(8/20μS)(Imax):
(KA)
30/40/60
30/40/60
30/40/60
30/40/60
Voltage protection
level (UP)(KV)
<1.5kV
<1.8kV
<2.0kV
<2.5kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Gray
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS4 AC Surge Protection Device
Application:
TRS4 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS4/□140
140
TRS4/□275
275
IEC category
TRS4/□320
TRS4/□385
320
TRS4/□440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
5/10/15/
20
5/10/15/
20
5/10/15/
20
5/10/15/
20
5/10/15/
20
Max discharge
current
(8/20μS)(Imax):
(KA)
10/20/30
/40
10/20/30
/40
10/20/30
/40
10/20/30
/40
10/20/30
/40
Voltage protection
level (UP)(KV)
<0.8kV
<1.2kV
<1.5kV
<1.8kV
<2.0kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Red/Black
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS5 AC Surge Protection Device
Application:
TRS5 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS4/□140
140
TRS4/□275
275
IEC category
TRS4/□320
TRS4/□385
320
TRS4/□440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
5/10/15/
20
5/10/15/
20
5/10/15/
20
5/10/15/
20
5/10/15/
20
Max discharge
current
(8/20μS)(Imax):
(KA)
10/20/30
/40
10/20/30
/40
10/20/30
/40
10/20/30
/40
10/20/30
/40
Voltage protection
level (UP)(KV)
<0.8kV
<1.2kV
<1.5kV
<1.8kV
<2.0kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Red/Gray
Strengthen fire resistance PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS6 AC Surge Protection Device
Application:
TRS6 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS6/□-275
275
TRS6/□-320
320
IEC category
TRS6 (convex)
TRS6/□-440
385
440
II
Nominal discharge
current
(In)(8/20μS)
(KA)
30/40/80
30/40/80
30/40/80
30/40/80
Max discharge
current
(8/20μS)(Imax):
(KA)
60/80/100
60/80/100
60/80/100
60/80/100
Voltage protection
level (UP)(KV)
<1.5kV
<1.8kV
<2.0kV
<2.5kV
Response time (ns)
Degree of
protection
TRS6 (flat)
TRS6/□-385
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Gray
Strengthen fire resistance PC PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS7 AC Surge Protection Device
Application:
TRS7 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS7/□-320
320
TRS7/□-385
TRS7/□-440
385
TRS7/□-660
440
IEC category
660
II
Nominal discharge
current
30/40/50/80 30/40/50/80 30/40/50/80 30/40/50/80
(In)(8/20μS)
(KA)
Max discharge
current
(8/20μS)(Imax):
(KA)
60/80/100/
150
60/80/100/
150
60/80/100/
150
60/80/100/
150
Voltage protection
level (UP)(KV)
<2.0kV
<2.5kV
<3.0kV
<3.5kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Gray
Strengthen fire resistance PC PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRS9 AC Surge Protection Device
Application:
TRS9 AC surge protection device suit for the AC 50Hz/60Hz . for the TT. TN-S . TN-C .and IT .not over 380V . It is
used to protect the direct or indirect thunder influence or other instantaneous over-voltage surge . This protect is
mainly used in house . thied industry field for surge protection . This product is comply with IEC 61643-1998
Technical Data
Type
Max continuous
operating voltage
(UC):(V)
TRS9/□-320
320
TRS9/□-385
TRS9/□-440
385
TRS9/□-660
440
IEC category
660
II
Nominal discharge
current
30/40/50/80 30/40/50/80 30/40/50/80 30/40/50/80
(In)(8/20μS)
(KA)
Max discharge
current
(8/20μS)(Imax):
(KA)
60/80/100/
150
60/80/100/
150
60/80/100/
150
60/80/100/
150
Voltage protection
level (UP)(KV)
<2.0kV
<2.5kV
<3.0kV
<3.5kV
Response time (ns)
Degree of
protection
Operating temp
range
Color
Frame material
Cross section area
≤25ns
IP20
-40℃--+80℃
Red Black
Strengthen fire resistance PC PBT
Phase wire :6-35mm2
Earthed wire:6-35mm2
Remote sig terminal: 1.5mm2
Accessonies
Addtion remote signal control
TRSS-RJ45 Data Line Surge Protection
Application
TRSS-RJ45 Multi-Connection signal surge arrester used for protecting Ethernet 100
Base-Y/TX . LAN and 10 Base -T(IEEE802.5) from damage for inductive thunderbolt
electric wave , surge and atatic interference
Technical data
TRSS-RJ45
Type
Nominal voltage Un(V)
5V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
60V
line-PE
250V
Max transfer speed
100MB/S
Response time (ns)
1ns
Connection inpotout put
RJ45
Pinning
1/2,3/6, 1-8
TRSS-RJ45-24 Data Line Surge Protection
Application
TRSS-BNC-24 multi-connection net signal surge arrester . used for protecting Ethernet
100 BASE T/TX . 100Vg-Any-LAN ,CDDI . OBASE-TIEEE802. EURO-ISDN etc . Like HUB from
damage for inductive thunder bolt electric wave . surge and static interference
Technical data
TRSS-RJ45-24
Type
Nominal voltage Un(V)
5V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
60V
line-PE
250V
Max transfer speed
100MB/S
Response time (ns)
1ns
Connection inpotout put
Pinning
RJ45
1/2,3/6, 1-8
TRSS-RJ11 Data Line Surge Protection
Application
TRSS-RJ11 signal surge arrester for public switched telephone network system ,ect. It
is used to protect the indirect thunder influence or other instantaneous over voltage
surge
Technical data
Type
TRSS-RJ11
Nominal voltage Un(V)
≤180V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
250V
line-PE
250V
Max transfer speed
2MB/S
Response time (ns)
1ns
Connection inpotout put
RJ11
Pinning
3/4
TRSS-485 Data Line Surge Protection
Application
TRSS-485 signal control surge arrester for transporting analog signals and controlling
system like: supervisory control system, communication system, PLC , MCR
,etc.Possessing low limiting voltage with high discharging capablity . It is used to
protect the indirect thunder influence or other instantaneous over voltage surge
Technical data
Type
TRSS-485
Nominal voltage Un(V)
24V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
65V
line-PE
65V
Max transfer speed
2MB/S
Response time (ns)
1ns
Connection inpotout put
CH 3.96terminal
TRSS-BNC Data Line Surge Protection
Application
TRSS-BNC is coaxial signal surge arrester for coaxial computer system like: 100 Base-2
, video and camera system, etc. it is used to protect the indirect thunder influence or
other instantaneous over-voltage surge
Technical data
TRSS-BNC
Type
Nominal voltage Un(V)
5V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
25V
line-PE
600V
Max transfer speed
16MB/S
Bestwith fo
≥20MHZ
Imax
≤0.3db
loss
Test socket connection loss
Connection inpotout put
≥20db
BNC
TRSS-BNC-24 Data Line Surge Protection
Application
TRSS-BNC-24 multi-connection net signal surge arrester . used for protecting Ethernet
100 BASE T/TX . 100Vg-Any-LAN ,CDDI . OBASE-TIEEE802.3 EURO-ISDN etc . Like HUB from
damage for inductive thunder bolt electric wave . surge and static interference
Technical data
TRSS-BNC-24
Type
Nominal voltage Un(V)
5V
Nominal discharge
current(In)(8/20μS)
5kA
Voltage protection
level (UP):
line-line
25V
line-PE
600V
Max transfer speed
16MB/S
Bestwith fo
≥20MHZ
Imax
loss
≤0.3db
Test socket connection loss
≥20db
Connection inpotout put
BNC
TRSS-BNC+2
Application
TRSS-BNC +2 surge arrester is mainly used for supervisory control system . preventing product form Lightning strike
and surge possessing three kinds of production for single-phase AC power source 24V
36V
48V and video
signal
Technical data
AC Power Source
Protection Class
III/C
Mode of connection
In series
Nominal voltage(Un)
220V AC
Voltage protection level(Up)
1800V
Max discharge current(In)(8/20μS) 10KA
485 Signal control
Nominal voltage Un(V)
24V DC
Voltage protection level(Up)
60V
Max discharge current(In)(8/20μS) 5KA
Video signal
Connection inputout put
BNC
Nominal voltage Un(V)
24V DC
Voltage protection level Lineline/line-PG(Up)
65V/300V
Max discharge current(In)(8/20μS) 5KA
Max transfer speed
20M
VSWR
<1.2
Insertion loss
<0.2dB
TRSS-DB Data Line Surge Protection
Technical data
Type
TRSS-DB25
Connection
and pinning
L:2/3 SG7
PGl
12
18
L:2/3/ 4/5
/6/8/20 Sg7
PG1
12
18
TRSS-DB25
TRSS-DB15 L:2/3 SG5
TRSS-DB9 PG1
TRSS-DB9
Un(V) Uc(V) Isn(8/2 transport
Note 5692a
0μS) speed≤bits 92a
≤KA
12
18
L:2/9/4/1
SG8 PG1
8
15
L:1/2/3/4/6/
7/8/9 SG5
PG
12
18
5
1M
5
1M
RS232
RS422
SDLC
RS423
RS485
HDLC
TRSS-W Coaxial surge arrester series
Technical data
Type
Gas tube discharge
connection
BNC
Frequency band
(MHz)
0--2000 0--1500 0--2000 0--1500 0--1500 0--1500 0--1500
Max continuous
voltage(Uc)(V)
BNC
F
<1.2
Insertion loss
<0.2
Max power
Response time (ns)
TNC
UHF
DIN7/1
6
DC68/AC130V/AC280V
VSWR
impedance
N
75
50
75
300W
1ns
50
500W
50
50
50
TRSB Lightning Rod Protection
Carachteristic&Benefits
1) 100% of efficacy in discharge capture
2) high level of protection
3) Electric continuity guaranteed The device does not offer any
resistance to discharge conduction
4) Lightning rod without electrical components , maxim durability
guaranteed.
5) It does not need external power supply
TYPE
TRSB-1/3.1 TRSB-1/3.3 TRSB-1/4.3 TRSB-1/5.3 TRSB-1/6.3
TRSL Socket surge arrester
Application
TRSL Socket surge arrester series is used for protecting electronic equipment from damage for inductve thunderbolt
electric wave, surge and static interference
Technical date
Max continuous operating voltage
(UC)(V)
275V/320V/385V-50Hz 60Hz
Nominal discharge
current(In)(8/20μS)
5KA
8KA
Max discharge current
(8/20us)(Imax)
8KA
15KA
Voltage protection level (UP):
1.0KV/1.2KV/1.5KV
Response time (ns)
≤2.5ns
Operating temp
-40℃--+80℃
TRS230 DC surge arrester series
Application:
DC surge arrester series used for protecting supervisory control system and 24V dc control from damage for inductive
thunderbolt electric wave, surge and static interference
Technical date
Nominal operating voltage
Un
TRS230-12 TRS2302-4 TRS230-36 TRS230-48
Nominal operating voltage
Un
12V DC
24V DC
36V DC
48V DC
Voltage protection level(Up)
40V
60V
80V
110V
Max discharge current
(8/20μS)(Imax): (Isn)
5kA
5kA
5kA
5kA
TRSX power supply arrester series
Application:
TRSX power supply arrester series is used for three- phase power supply system, The protective device sort is class B.
connected parallel in power supply system, preventing from damage for inductive thunderbolt electric wave , surge and
static interference
Technical date
Type
TRSX-20
TRSX-40
Nominal operating
voltage Un
AC380V
Max continuous
voltage(Uc)(V)
AC440V
TRSX-80
TRSX-60
TRSX-100
20
Max discharge
current(In)(8/2
0μS)
40
60
80
100
Nominal discharge 10
current(In)(8/2
0μS)
20
30
40
50
Response time
(ns)
Voltage protection
level(8/20μS3KA
)Up(V)
Protection mode
Connection way
Remote signal
control
Frequency
Operating temp
≤2.5ns
≤800
≤1000
≤1200
L1/L2/L3-N
≤1500
N-PE
In parallel
Yes
47--63Hz
-40℃--+85℃
≤2000