RJT 1x4, 2x2, 2x4 LED Troffer Product Information Project Name Type Catalog Number Date SPECIFICATIONS Features • The RJT is a direct replacement for fluorescent troffers and offers the right options for versatility of use across a wide range of project types. • Choice of four lumen packages and dimming option available. • Same LED door styles, lens types and mounting for 1x4, 2x2 or 2x4 configurations. • Long-life, LEDs at L80 (80% lumen maintenance) at 60,000 hours to reduce life cycle maintenance costs. • Optional emergency battery backup for safety lighting. • Available in 2' and 4' lengths. • Up to 107 lumens per watt. • Color Rendering Index (CRI) > 80. • Multiple shielding options. Construction • Fixture housing, end caps, and reflectors are die-formed code-gauged cold-rolled steel • Hinged optical system allows easy access to LED modules and electrical from below the ceiling • Multiple shielding options. Certain airborne contaminants can diminish integrity of acrylic. Contact factory for chemical compatibility. • Metal to metal light leak protection on all four sides of shielding frame • Two door frame choices • Weight: 1x4-8 lbs. 2x2-7 lbs. 2x4-10 lbs. Electrical • • • • • • • • • Input Voltage Range: 120-277 VAC Nom. Frequency: 50/60 Hz Nom. Active Power Factor Correction Power Factor: >0.90 @ full load, 120V through 277V Harmonic Distortion: THD < 20% @ full load Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit Compliant to FCC Part 15 requirements for EMI/RFI emissions NEC/CEC compliant ballast disconnect is standard. Optional emergency battery pack Certifications • • • • • • CSA listed for Canada and U.S. Tested to UL 1598 & UL 8750 standards. Luminaires bear appropriate listing labels. Emergency-equipped fixtures labeled UL 924. Adheres to LM79, LM80 and TM21 industry standards. DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www.designlights.org. • Please refer to the Lighting Facts website for specific product qualifications at www.lightingfacts.com. Application • Suitable for use with most wired or wireless lighting control systems • Suitable for dry & damp locations: • Government buildings • Retail • Commercial areas • Healthcare facilities • Educational facilities Warranty • Five-year warranty. (Terms and Conditions Apply) CERTIFICATION ORDERING INFORMATION RJT MODEL RJT LED Lensed Troffer Fixture SIZE 14 1x4 Nominal 22 2×2 Nominal 24 2x4 Nominal EXAMPLE RJT22-35HLG-FSA12F-EU – – COLOR TEMP 30 35 40 50 3000K 3500K 4000K 5000K LUMEN OUTPUT LW Low (2x4 Only) ML Medium (2x2, 2x4) HL High (2x2,2x4) VL Very High (2x2, 2x4) XL Extra High Lumen (2x4 Only) Page 1/4 - Revised: 05/26/16 | Created: 2016 CEILING TYPE G Grid1 SM Surface Mount DOOR FS White Flush Steel FA White Flush Aluminum – SHIELDING A12 Pattern 12 Acrylic Lens A12125 Pattern 12 Acrylic Lens, 0.125" Nominal A12F Pattern 12 Frosted Acrylic Lens A12F125 Pattern 12 Frosted Acrylic Lens, 0.125" Nominal A19 Pattern 19 Acrylic Lens, 0.156" Nominal A19F Pattern 19 Frosted Acrylic Lens 0.156" FOOTNOTES 1. For hard ceilings use flange kit accessory (order separately). 2. Bi-Level driver must be controlled by sensor or A/B switching. 3. Must be used in conjunction with lighting controls. 4. Not available with surface mount. U DRIVER OUTPUT E Fixed ESD Bi-Level2 ED 0-10V – OTHER ELL14 Emergency Battery Pack4 C388 3-Wire Flex, 6', 18 Ga Dimming3 C488 4-Wire Flex, DRIVER VOLTAGE C588 5-Wire Flex, 6', 18 Ga 6', 18 Ga U Universal 120/277 VAC ACCESSORIES (ORDER SEPARATELY) FK14 1'x 4' Single Flange Kit FK22 2'x 2' Single Flange Kit FK24 2'× 4' Single Flange Kit © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer PHOTOMETRIC DATA PHOTOMETRIC DATA: RJT14-40ML-XXA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT14-40ML-XXA12-EDU LED Lensed Troffer Fixture 1x4 LED with A12 patern acrylic prismed lens D10C55UNVTC 1.00 LED 3860 39 Recessed 0° = 90 90° = 90 0° = 1.23 90° = 1.13 Length: 3.81 Width: 0.83 Height: 0.00 Test: L051401401 Test Date: 05/22/14 INDOOR CANDELA PLOT 90 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 98 Noncompliant 75 $2.42 based on 3000 hrs. and $0.08 per KWH 950 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 1445 2253 3365 3860 37 58 87 100 37 58 87 100 60 1900 0 15 30 Horiz 0-180 45 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ PHOTOMETRIC DATA: RJT22-35MLG-FSA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT22-35MLG-FSA12-ESD LED Lensed Troffer Fixture D15CC55UNVT-C 1.00 LED 3261 35 Recessed 0° = 90 90° = 90 0° = 1.12 90° = 1.16 Length: 1.82 Width: 1.83 Height: 0.00 Test: L051401401 Test Date: 05/22/14 INDOOR CANDELA PLOT 90 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 93 Noncompliant 75 $2.58 based on 3000 hrs. and $0.08 per KWH 800 ZONAL LUMEN SUMMARY Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 1176 1834 2785 3261 36 56 85 100 36 56 85 100 60 1600 0 15 30 Horiz 0-180 45 0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _ PHOTOMETRIC DATA: RJT24-35MLG-FSA12-EDU All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab. LUMINAIRE DATA ENERGY DATA Luminaire Ballast Ballast Factor Lamp Fixture Lumens Watts Mounting Shielding Angle Spacing Criterion Luminous Opening in feet RJT24-35MLG-FSA12-EDU LED Low Profile Wrap D15CC55UNVT-C 1.00 LED 4772 45 Recessed 0º = 90 90º = 90 0º = 1.17 90º = 1.17 Length: 3.81 Width: 1.80 Height: 0.00 Test: L051401202 Test Date: 05/14/14 INDOOR CANDELA PLOT 90 Total Luminaire Efficiency 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 Compliance Comparative Yearly Lighting Energy Cost per 1000 Lumens 105 Noncompliant $2.26 based on 3000 hrs. and $0.08 per KWH 75 1100 ZONAL LUMEN SUMMARY 60 Zone Lumens %Lamp %Fixt 0-30 0-40 0-60 0-90 1636 2586 4044 4772 34 54 85 100 34 54 85 100 2200 0 15 30 45 Horiz 0-180 0.0 _____ 45.0 _ _ _ _ 90.0 _ _ _ _ Page 2/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer LUMEN PACKAGE OPTIONS 4000K DETAILS 3500K DETAILS Proposed System CRI RJT14-LW RJT14-ML RJT14-HL RJT14-VL RJT22-ML RJT22-HL RJT22-VL RJT24-LW RJT24-ML RJT24-HL RJT24-VL RJT24-XL >80 >80 >80 >80 >80 >80 >80 >80 >80 >80 >80 >80 CCT Lumens Per Fixture Input Watts Lumens Per Watt 3500K 3500K 3500K 3500K 3500K 3500K 3500K 3500K 3500K 3500K 3500K 3500K 2,489 3,607 4,430 4,920 3,261 3,845 4,329 4,151 4,772 5,490 6,941 8,352 26 39 50 54 35 43 51 39 45 49 68 85 96 92 88 91 93 89 85 107 106 112 102 99 CCT Lumens Per Fixture Input Watts Lumens Per Watt 4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K 4000K 2,606 3,860 4,755 5,351 3,472 4,051 4,552 4,234 4,867 5,600 7,080 8,500 26 39 51 55 35 43 50 40 46 51 69 85 102 98 94 97 99 94 91 107 105 110 102 100 *Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards. FIXTURE DIMENSIONS 1X4 CROSS SECTION 4.8125" 12" 2X4 CROSS SECTION 2X2 CROSS SECTION 3.125" 4.250" 24" 24" 2X4 TOP VIEW 2X2 TOP VIEW 48" 4.500" A 24" 3" K A- 7/8" Diameter Knockout K- 2"x 3" through hole for access plate 3" 3.15625" 3.09375" A 4.250" K 16.500" A- 7/8" Diameter Knockout K- 2"x 3" through hole for access plate *Drawings N.T.S. Page 3/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com RJT 1x4, 2x2, 2x4 LED Troffer SURFACE MOUNT DIMENSIONS 1X4 DIMENSIONS 43" 2.875" 7/8" Feed KO 2.875" A A 5.25" A 9.5" 2X4 DIMENSIONS 2X2 DIMENSIONS 44.625" Mounting Holes: (4) 1/4"-1/2" DIA KOs 4.750" 12.375" 5.5625" 21.625" Mounting Holes: (4) 1/4"-1/2" DIA KOs 12.375" 14" 1 ½" Thru Hole 4 1/2" x 5" Mounting Collar (SM). 12.375" 15" 1 ½" Thru Hole 4 1/2" x 5" Mounting Collar (SM). 5" *Drawings N.T.S. CEILING COMPATIBILITY TYPE G FLANGE KIT End Side For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. End Side For hard ceiling applications order flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. *Drawings N.T.S. Page 4/4 - Revised: 05/26/16 | Created: 2016 © 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com