SPECIFICATIONS
Features
• The RJT is a direct replacement for fluorescent troffers and offers the right
options for versatility of use across a wide range of project types.
• Choice of four lumen packages and dimming option available.
• Same LED door styles, lens types and mounting for 1x4, 2x2 or 2x4 configurations.
• Long-life, LEDs at L80 (80% lumen maintenance) at 60,000
hours to reduce life cycle maintenance costs.
• Optional emergency battery backup for safety lighting.
• Available in 2' and 4' lengths.
• Up to 107 lumens per watt.
• Color Rendering Index (CRI) > 80.
• Multiple shielding options.
Construction
• Fixture housing, end caps, and reflectors are die-formed
code-gauged cold-rolled steel
• Hinged optical system allows easy access to LED modules
and electrical from below the ceiling
• Multiple shielding options. Certain airborne contaminants can diminish
integrity of acrylic. Contact factory for chemical compatibility.
• Metal to metal light leak protection on all four sides of shielding frame
• Two door frame choices
• Weight: 1x4-8 lbs. 2x2-7 lbs. 2x4-10 lbs.
Electrical
•
•
•
•
•
•
•
•
•
Input Voltage Range: 120-277 VAC Nom.
Frequency: 50/60 Hz Nom.
Active Power Factor Correction
Power Factor: >0.90 @ full load, 120V through 277V
Harmonic Distortion: THD < 20% @ full load
Protection: Over-Voltage, Over-Temperature (110º) & Short Circuit
Compliant to FCC Part 15 requirements for EMI/RFI emissions
NEC/CEC compliant ballast disconnect is standard.
Optional emergency battery pack
Certifications
•
•
•
•
•
•
CSA listed for Canada and U.S. Tested to UL 1598 & UL 8750 standards.
Luminaires bear appropriate listing labels.
Emergency-equipped fixtures labeled UL 924.
Adheres to LM79, LM80 and TM21 industry standards.
DesignLights Consortium® (DLC) qualified.
Please refer to the DLC website for specific product qualifications
at www.designlights.org.
• Please refer to the Lighting Facts website for specific product qualifications
at www.lightingfacts.com.
Application
• Suitable for use with most wired or wireless lighting control systems
• Suitable for dry & damp locations:
• Government buildings
• Retail
• Commercial areas
• Healthcare facilities
• Educational facilities
Warranty
• Five-year warranty. (Terms and Conditions Apply)
CERTIFICATION
ORDERING INFORMATION
RJT
MODEL
RJT LED
Lensed
Troffer
Fixture
SIZE
14 1x4
Nominal
22 2×2
Nominal
24 2x4
Nominal
EXAMPLE RJT22-35HLG-FSA12F-EU
–
–
COLOR
TEMP
30
35
40
50
3000K
3500K
4000K
5000K
LUMEN
OUTPUT
LW Low
(2x4 Only)
ML Medium
(2x2, 2x4)
HL High
(2x2,2x4)
VL Very High
(2x2, 2x4)
XL Extra High
Lumen
(2x4 Only)
Page 1/4 - Revised: 05/26/16 | Created: 2016
CEILING
TYPE
G Grid1
SM Surface
Mount
DOOR
FS White Flush
Steel
FA White Flush
Aluminum
–
SHIELDING
A12 Pattern 12
Acrylic Lens
A12125 Pattern 12 Acrylic
Lens, 0.125" Nominal
A12F Pattern 12
Frosted Acrylic Lens
A12F125 Pattern 12
Frosted Acrylic Lens,
0.125" Nominal
A19 Pattern 19 Acrylic
Lens, 0.156" Nominal
A19F Pattern 19 Frosted
Acrylic Lens 0.156"
FOOTNOTES
1. For hard ceilings use flange kit accessory (order separately).
2. Bi-Level driver must be controlled by sensor or A/B switching.
3. Must be used in conjunction with lighting controls.
4. Not available with surface mount.
U
DRIVER
OUTPUT
E Fixed
ESD Bi-Level2
ED 0-10V
–
OTHER
ELL14 Emergency
Battery Pack4
C388 3-Wire Flex,
6', 18 Ga
Dimming3
C488 4-Wire Flex,
DRIVER
VOLTAGE
C588 5-Wire Flex,
6', 18 Ga
6', 18 Ga
U Universal
120/277 VAC
ACCESSORIES
(ORDER SEPARATELY)
FK14 1'x 4' Single Flange Kit
FK22 2'x 2' Single Flange Kit
FK24 2'× 4' Single Flange Kit
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RJT
1x4, 2x2, 2x4 LED Troffer
PHOTOMETRIC DATA
PHOTOMETRIC DATA: RJT14-40ML-XXA12-EDU
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
ENERGY DATA
Luminaire
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
RJT14-40ML-XXA12-EDU
LED Lensed Troffer Fixture
1x4 LED with A12 patern
acrylic prismed lens
D10C55UNVTC
1.00
LED
3860
39
Recessed
0° = 90 90° = 90
0° = 1.23 90° = 1.13
Length: 3.81
Width: 0.83
Height: 0.00
Test: L051401401
Test Date: 05/22/14
INDOOR CANDELA PLOT
90
Total Luminaire Efficiency
100.0%
Total Lumens per Watt
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
98
Noncompliant
75
$2.42 based on
3000 hrs. and
$0.08 per KWH
950
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
1445
2253
3365
3860
37
58
87
100
37
58
87
100
60
1900
0
15
30
Horiz 0-180
45
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
PHOTOMETRIC DATA: RJT22-35MLG-FSA12-EDU
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
ENERGY DATA
Luminaire
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
RJT22-35MLG-FSA12-ESD
LED Lensed Troffer Fixture
D15CC55UNVT-C
1.00
LED
3261
35
Recessed
0° = 90 90° = 90
0° = 1.12 90° = 1.16
Length: 1.82
Width: 1.83
Height: 0.00
Test: L051401401
Test Date: 05/22/14
INDOOR CANDELA PLOT
90
Total Luminaire Efficiency
100.0%
Total Lumens per Watt
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
93
Noncompliant
75
$2.58 based on
3000 hrs. and
$0.08 per KWH
800
ZONAL LUMEN SUMMARY
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
1176
1834
2785
3261
36
56
85
100
36
56
85
100
60
1600
0
15
30
Horiz 0-180
45
0.0 _____ 40.0 _ _ _ _ 90.0 _ _ _ _
PHOTOMETRIC DATA: RJT24-35MLG-FSA12-EDU
All published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP certified lab.
LUMINAIRE DATA
ENERGY DATA
Luminaire
Ballast
Ballast Factor
Lamp
Fixture Lumens
Watts
Mounting
Shielding Angle
Spacing Criterion
Luminous Opening
in feet
RJT24-35MLG-FSA12-EDU
LED Low Profile Wrap
D15CC55UNVT-C
1.00
LED
4772
45
Recessed
0º = 90 90º = 90
0º = 1.17 90º = 1.17
Length: 3.81
Width: 1.80
Height: 0.00
Test: L051401202
Test Date: 05/14/14
INDOOR CANDELA PLOT
90
Total Luminaire Efficiency
100.0%
Total Lumens per Watt
ANSI/IESNA RP-1-2004
Compliance
Comparative Yearly Lighting
Energy Cost per 1000 Lumens
105
Noncompliant
$2.26 based on
3000 hrs. and
$0.08 per KWH
75
1100
ZONAL LUMEN SUMMARY
60
Zone
Lumens
%Lamp
%Fixt
0-30
0-40
0-60
0-90
1636
2586
4044
4772
34
54
85
100
34
54
85
100
2200
0
15
30
45
Horiz 0-180
0.0 _____ 45.0 _ _ _ _ 90.0 _ _ _ _
Page 2/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RJT
1x4, 2x2, 2x4 LED Troffer
LUMEN PACKAGE OPTIONS
4000K DETAILS
3500K DETAILS
Proposed
System
CRI
RJT14-LW
RJT14-ML
RJT14-HL
RJT14-VL
RJT22-ML
RJT22-HL
RJT22-VL
RJT24-LW
RJT24-ML
RJT24-HL
RJT24-VL
RJT24-XL
>80
>80
>80
>80
>80
>80
>80
>80
>80
>80
>80
>80
CCT
Lumens
Per Fixture
Input
Watts
Lumens
Per Watt
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
3500K
2,489
3,607
4,430
4,920
3,261
3,845
4,329
4,151
4,772
5,490
6,941
8,352
26
39
50
54
35
43
51
39
45
49
68
85
96
92
88
91
93
89
85
107
106
112
102
99
CCT
Lumens
Per Fixture
Input
Watts
Lumens
Per Watt
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
4000K
2,606
3,860
4,755
5,351
3,472
4,051
4,552
4,234
4,867
5,600
7,080
8,500
26
39
51
55
35
43
50
40
46
51
69
85
102
98
94
97
99
94
91
107
105
110
102
100
*Lumen values shown are initial delivered lumens tested at 25°C per IES LM-79 standards.
FIXTURE DIMENSIONS
1X4 CROSS SECTION
4.8125"
12"
2X4 CROSS SECTION
2X2 CROSS SECTION
3.125"
4.250"
24"
24"
2X4 TOP VIEW
2X2 TOP VIEW
48"
4.500"
A
24"
3"
K
A- 7/8" Diameter Knockout
K- 2"x 3" through hole for access plate
3"
3.15625"
3.09375"
A
4.250"
K
16.500"
A- 7/8" Diameter Knockout
K- 2"x 3" through hole for access plate
*Drawings N.T.S.
Page 3/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
RJT
1x4, 2x2, 2x4 LED Troffer
SURFACE MOUNT DIMENSIONS
1X4 DIMENSIONS
43"
2.875"
7/8"
Feed KO
2.875"
A
A
5.25"
A
9.5"
2X4 DIMENSIONS
2X2 DIMENSIONS
44.625"
Mounting
Holes: (4)
1/4"-1/2"
DIA KOs
4.750"
12.375"
5.5625"
21.625"
Mounting
Holes: (4)
1/4"-1/2"
DIA KOs
12.375"
14"
1 ½"
Thru
Hole
4 1/2" x 5"
Mounting Collar (SM).
12.375"
15"
1 ½"
Thru
Hole
4 1/2" x 5"
Mounting Collar (SM).
5"
*Drawings N.T.S.
CEILING COMPATIBILITY
TYPE G
FLANGE KIT
End
Side
For lay-in installation in exposed grid ceilings. Maximum tee
widths of 1" and maximum tee heights of 2" allowed.
End
Side
For hard ceiling applications order flange kit. Flange kit wires directly
into concealed ceiling opening for a clean, finished appearance.
*Drawings N.T.S.
Page 4/4 - Revised: 05/26/16 | Created: 2016
© 2016 Precision-Paragon [P2], a division of Hubbell Lighting, Inc. Because of continuing product improvement programs, Precision-Paragon [P2] reserves
the right to change specifications without notice. Telephone [Midwest] 715.381.2971 / Website www.P-2.com
Download