WHITE GOODS FILTERS
LCR 095/02
High Ambient, High Surge Washing Machine and White Goods Filters
Features
VDE approved per EN60939-2 and UL approved per UL1283, design to operate in 70°C
ambient, small and compact EMI filters.
L
Cy
L
Cx
R
Washing machine, refrigerator, air conditioner and other appliances.
2
Cy
Typical Applications
1
Unique capacitor combination provides higher safety/surge performances and better
EMI performances in a very economical solution with standard RAST 5 connection.
Electrical Schematic
N
A
095/02 - Electrical Schematic
Specifications
L
Rated Current (A)
4-16 A @ 70°C
Frequency (Hz)
50/60 Hz
Leakage Current
L
Cx
R
@ 250 VAC 50 Hz
N
@ 120 VAC 60 Hz B
095M/02 - Electrical Schematic
Hipot Rating
IP Class
2
120/250 VAC
1
Rated Voltage Max. (V)
0.89/2.08 mA Max.
0.49/1.15 mA Max.
IP68
Line to Line
1450 VDC
Flammability
UL 94 V-0
Line to Ground
2250 VDC
GWFI (EN 60695-2-12)
> 850°C
3 KV/5 KV
GWIT (EN 60695-2-13)
> 750°C
Surge per EN61000-4-5
Case
Modified Plastic
CTI (EN 60112)
> 250 V
Climatic Category (EN60068-1)
25/100/21
BPT (EN 60695-10-2)
> 125°C
Specifications are subject to change. Consult factory to verify specifications.
For more information on our filter products call us at: (800) 527-4362 or (714) 289-0055
LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI
www.AstrodyneTDI.com
WHITE GOODS FILTERS
LCR 095/02
High Ambient, High Surge Washing Machine and White Goods Filters
Rated Current
(A) @ 70°C
L (mH)
095.20603.00
6
1.8
1.0
NA
470 K
A
095.21001.00
10
2.0
1.0
2.2
470 K
095.21201.00
12
1.0
0.68
22.0
470 K
095.21202.00
12
0.5
0.47
22.0
095.21601.00
16
3.0
1.0
2.2
095.21603.00
16
3.0
1.0
095.21615.00
16
1.0
095.21624.00
16
1.0
Model No.
Cx (uF)
Cy (nF)
R (Ω)
Schematic
Terminal Options
Unit Weight (g)
In
Out
120
QD 6.35*0.8
QD 6.35*0.8
A
120
QD 6.35*0.8
QD 6.35*0.8
A
120
QD 6.35*0.8
QD 6.35*0.8
470 K
A
120
QD 6.35*0.8
QD 6.35*0.8
470 K
A
120
QD 6.35*0.8
QD 6.35*0.8
2.2
330 K
A
120
QD 6.35*0.8
QD 6.35*0.8
0.47
4.7
680 K
A
120
QD 6.35*0.8
QD 6.35*0.8
0.47
22.0
680 K
A
120
QD 6.35*0.8
QD 6.35*0.8
LCR 095/02 Mechanical Outlines
55
45
36
The difference between A/B
22
35
25
42
21.5
28.5
16.5
31.5
Front View
Left View
3.3
3x
1.7
19
26
10
Top View
A
B
LCR 095/02 Insertion Loss in dB Measured in a 50 Ω System
Differential Mode
Common Mode
80.00
60
40
60
40
20
20
0
0
0.1
1
Frequency (MHz) 10
Insertion Loss (dB)
100.00
80
Insertion Loss (dB)
100
80
Insertion Loss (dB)
100
40.00
20.00
0.00
0.1
100
60.00
095.20603.00
1
Frequency (MHz)
10
0.1
100
095.21001.00
80
40.00
60
40
20.00
20
0.00
0
0.1
1
Frequency (MHz)
10
095.21202.00
100
Insertion Loss (dB)
100
80
Insertion Loss (dB)
100
80.00
Insertion Loss (dB)
100.00
60.00
1
Frequency (MHz)
10
100
095.21201.00
60
40
20
0
0.1
1 Frequency (MHz) 10
095.21601.00
100
0.1
1 Frequency (MHz) 10
100
095.21602.00
Specifications are subject to change. Consult factory to verify specifications.
For more information on our filter products call us at: (800) 527-4362 or (714) 289-0055
LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI
www.AstrodyneTDI.com
Download