WHITE GOODS FILTERS LCR 095/02 High Ambient, High Surge Washing Machine and White Goods Filters Features VDE approved per EN60939-2 and UL approved per UL1283, design to operate in 70°C ambient, small and compact EMI filters. L Cy L Cx R Washing machine, refrigerator, air conditioner and other appliances. 2 Cy Typical Applications 1 Unique capacitor combination provides higher safety/surge performances and better EMI performances in a very economical solution with standard RAST 5 connection. Electrical Schematic N A 095/02 - Electrical Schematic Specifications L Rated Current (A) 4-16 A @ 70°C Frequency (Hz) 50/60 Hz Leakage Current L Cx R @ 250 VAC 50 Hz N @ 120 VAC 60 Hz B 095M/02 - Electrical Schematic Hipot Rating IP Class 2 120/250 VAC 1 Rated Voltage Max. (V) 0.89/2.08 mA Max. 0.49/1.15 mA Max. IP68 Line to Line 1450 VDC Flammability UL 94 V-0 Line to Ground 2250 VDC GWFI (EN 60695-2-12) > 850°C 3 KV/5 KV GWIT (EN 60695-2-13) > 750°C Surge per EN61000-4-5 Case Modified Plastic CTI (EN 60112) > 250 V Climatic Category (EN60068-1) 25/100/21 BPT (EN 60695-10-2) > 125°C Specifications are subject to change. Consult factory to verify specifications. For more information on our filter products call us at: (800) 527-4362 or (714) 289-0055 LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI www.AstrodyneTDI.com WHITE GOODS FILTERS LCR 095/02 High Ambient, High Surge Washing Machine and White Goods Filters Rated Current (A) @ 70°C L (mH) 095.20603.00 6 1.8 1.0 NA 470 K A 095.21001.00 10 2.0 1.0 2.2 470 K 095.21201.00 12 1.0 0.68 22.0 470 K 095.21202.00 12 0.5 0.47 22.0 095.21601.00 16 3.0 1.0 2.2 095.21603.00 16 3.0 1.0 095.21615.00 16 1.0 095.21624.00 16 1.0 Model No. Cx (uF) Cy (nF) R (Ω) Schematic Terminal Options Unit Weight (g) In Out 120 QD 6.35*0.8 QD 6.35*0.8 A 120 QD 6.35*0.8 QD 6.35*0.8 A 120 QD 6.35*0.8 QD 6.35*0.8 470 K A 120 QD 6.35*0.8 QD 6.35*0.8 470 K A 120 QD 6.35*0.8 QD 6.35*0.8 2.2 330 K A 120 QD 6.35*0.8 QD 6.35*0.8 0.47 4.7 680 K A 120 QD 6.35*0.8 QD 6.35*0.8 0.47 22.0 680 K A 120 QD 6.35*0.8 QD 6.35*0.8 LCR 095/02 Mechanical Outlines 55 45 36 The difference between A/B 22 35 25 42 21.5 28.5 16.5 31.5 Front View Left View 3.3 3x 1.7 19 26 10 Top View A B LCR 095/02 Insertion Loss in dB Measured in a 50 Ω System Differential Mode Common Mode 80.00 60 40 60 40 20 20 0 0 0.1 1 Frequency (MHz) 10 Insertion Loss (dB) 100.00 80 Insertion Loss (dB) 100 80 Insertion Loss (dB) 100 40.00 20.00 0.00 0.1 100 60.00 095.20603.00 1 Frequency (MHz) 10 0.1 100 095.21001.00 80 40.00 60 40 20.00 20 0.00 0 0.1 1 Frequency (MHz) 10 095.21202.00 100 Insertion Loss (dB) 100 80 Insertion Loss (dB) 100 80.00 Insertion Loss (dB) 100.00 60.00 1 Frequency (MHz) 10 100 095.21201.00 60 40 20 0 0.1 1 Frequency (MHz) 10 095.21601.00 100 0.1 1 Frequency (MHz) 10 100 095.21602.00 Specifications are subject to change. Consult factory to verify specifications. For more information on our filter products call us at: (800) 527-4362 or (714) 289-0055 LCR, Radius Power, and Filter Concepts are now part of Astrodyne TDI www.AstrodyneTDI.com