Grid to Chip Surge Protection - Industrial Automation Nation

advertisement
Surge Protection
For Business-Critical ContinuityTM
Grid to Chip Surge Protection
Product Catalog
Power Quality Solutions for
ALL 'our Application Needs
“Dirty” power is a problem. Whether it’s called a
surge, spike, transient or noise, “dirty” power is an abnormality in
the power that runs your facility. These power problems can leave
buildings in the dark and disable equipment, costing you thousands
in repairs and lost revenue. Your productivity uptime and reputation
depend on consistent power quality. Emerson Network Power Surge
Protection provides products and solutions that ensure reliability
from Grid to Chip. For more than 30 years, Facility Managers,
Engineers, and System Integrators have trusted Emerson Network
Power Surge Protection products to protect critical equipment in
the Industrial Process, Computing, Research/Testing and
Communications fields.
Emerson Network Power Surge Protection and the IEEE Standard
1100-1999 (Emerald Book) recommend a properly rated surge
protection device should be applied on ALL electrical conductors
entering your facility including: power, voice, and data. Without
proper protection – data disruption, hardware stress or destruction
could occur.
As a line of defense against damaging transients, Emerson Network
Power Surge Protection manufactures products in the following
categories:
■ Transient Voltage Surge Suppressors (TVSS) — which focus on
limiting high-voltage spikes to an acceptable level
■ Filtering/Line Conditioning — protect against low-energy
transients and high frequency noise and finally\
■ Data/Signal Line Protection — products guard sensitive
instrumentation against what we refer to as abackdoor’
transients and noise.
Why allow “dirty” power to put your equipment at risk Turn
to Emerson Network Power Surge Protection products for
peace of mind. We provide solutions for all your application needs
and the foundation for Business-Critical ContinuityX.
Table of Contents
Products
Page #
TRANSIENT VOLTAGE SURGE SUPPRESSION
TVSS — Product Selection Guide
IslaGuard® — IH Series
IslaGuard® — IM Series
IslaGuard® — IL Series
IslaGuard® — IH, IM, IL Ordering Information
DRS Series
Edco EMC-240B — 120/240 VAC Heavy Duty (Parallel)
Edco FAS-120AC — 120 VAC Medium Duty (Parallel) AC-Hardware
2
3
4
5
6
7
8
8
FILTERING/LINE CONDITIONING
Filtering/Line Conditioning — Product Selection Guide
Islatrol® IE Series — Active Tracking Filter®
Islatrol® IC+/LRIC+ Series — Active Tracking Filter®
Islatrol® — E Series — Active Tracking Filter® for DC Voltages
Islatrol® — SP-6TVN — Industrial Strength Surge Suppression (Series)
Islatrol® — RM Series — 120 VAC Rackmount
9
10
12
13
14
15
DATA/SIGNAL LINE PROTECTION
Data/Signal Line Protection — Product Selection Guide
Edco DRS (DC) Series — DIN Rail Protection
Edco PC642 Series — Zone/Loop/Data
Edco PHC Series — Two-Pair Signaling Circuit Protector (Modular)
Edco RJA-RJD Series — RJ-45 Telephone/Data
Edco RM-CAT6-16POE — CAT6-16POE Channel Rackmount
Edco CX-HFN-FF/CX-HFN-FM — High Frequency Line Protector — N-Type
Edco SLAC Series — AC Power/Signal
Edco SS64 & SS65 Series — Wastewater/Industrial Applications
Edco CX Series — CCTV & Data Applications/Coax
Edco RM-CXO6-16R — Channel Rackmount
16
17
18
19
20
21
21
22
23
24
24
TECHNICAL BULLETINS
High-Density Multiple Input Rack
Surge Protection for the Water Industry
Surge Protection for Power and Signal Lines
25
26
27
Transient Voltage Surge Suppression
TVSS — Product Selection Guide
Find your application in the left column.
Then look across for the appropriate product.
PRODUCTS
APPLICATIONS
Facility Service
Entrance
Distribution Panels
Sub-Distribution
Panels
Branch Panelboards
(Commercial)
Branch Panelboards
(Residential)
Motor Control Centers
Control Panels
(AC Power)
Various OEM Equipment
2
IslaGuard®
IH
Series
IslaGuard®
IM
Series
IslaGuard®
IL
Series
DRS
Series
Edco
EMC
Series
Edco
FAS
Series
Transient Voltage Surge Suppression
IslaGuard® — IH Series
Modular Surge Protective Device (SPD) capable of handling the high-impulse,
potentially damaging transients commonly found at the service entrance or
distribution panels. Its robust design allows for placement and protection in the
most severe exposure locations.
Features
■ Surge current capacity — 100,000 to
400,000 Amps per phase
■ Status indication includes: audible alarm,
form C contact, and internal/external
status indication
■ Replaceable modules ensure protected
mode flexibility
■ Optional equipment includes rotary
disconnect, surge counter, NEMA 3R,
4 or 4X enclosures
■ All voltage and phase configurations
■ Unique MOV/silver link fuse array enables
the IH Series to deliver the industry’s most
robust design; Coordination between fuse
gauge and MOV ensures repeatable
strike performance
■ 5 year warranty
Performance Technical Specifications
General Technical Specifications
Clamping
Peak Surge Current Capability (8 x 20 µs)
Operating Voltage Range
UL 1449 Classification*
Model: IHxxxx400
Fault Current Rating (AIC)
120/208
Phase:
400,000 Amps
Operating Frequency Range
Line to Neutral
500 Volts
L-N:
200,000 Amps
Capacity
Line to Line
700 Volts
L-L:
200,000 Amps
50 ⍀ EMI/RFI Attenuation
Line to Ground
500 Volts
L-G:
200,000 Amps
Response Time
Neutral to Ground
400 Volts
N-G:
200,000 Amps
Operating Temperature
277/480
Line to Neutral
Line to Line
Model: IHxxxx200
900 Volts
200,000 Amps
Certifications
Warranty
1,600 Volts
L-N:
100,000 Amps
900 Volts
L-L:
100,000 Amps
Neutral to Ground
800 Volts
L-G:
100,000 Amps
N-G:
100,000 Amps
Line to Line
1,800 Volts
Model: IHxxxx200-2
Line to Ground
1,800 Volts
Phase:
200,000 Amps
L-N:
200,000 Amps
L-L:
200,000 Amps
* UL classifications for other voltages available
upon request.
L-G:
N-G:
200 kAIC
47 - 63 Hz
Continuous
50 dB
< 0.5 ns
-40°C to +50°C
Operating Humidity
Phase:
Line to Ground
480
+/- 15%
0% to 95%
UL 1449, 1283, CUL, CE
5 Year
Dimensional Diagram
N/A
200,000 Amps
Model: IHxxxx100-2
Phase:
100,000 Amps
Model
A
B
C
D
E
F
L-N:
100,000 Amps
IHxxxY400
16
14
8
16.75
12
.31
L-L:
100,000 Amps
IHxxxD400
16
14
8
16.75
12
.31
L-G:
N/A
IHxxxY200-2 16
14
8
16.75
12
.31
100,000 Amps
IHxxxD200-2 16
14
8
16.75
12
.31
IHxxxY200
16
14
8
16.75
12
.31
IHxxxD200
16
14
8
16.75
12
.31
IHxxxY100-2 16
14
8
16.75
12
.31
IHxxxD100-2 16
14
8
16.75
12
.31
N-G:
3
Transient Voltage Surge Suppression
IslaGuard® — IM Series
A compact Surge Protective Device (SPD) designed to protect electronic
equipment and microprocessor-based systems from transients on distribution
and sub-distribution panels, or any medium exposure locations.
Features
■ Form C contact for remote indication,
LED status indication, and audible
alarm standard
■ Surge current capacity — 100,000 to
160,000 Amps per phase
■ All mode and 2 mode protection option
■ Sand encapsulation
■ Small footprints
■ Thermal protection
■ All voltage and phase configurations
■ Silver link fusing
■ NEMA 12 metal enclosure
■ 5 year warranty
Performance Technical Specifications
General Technical Specifications
Clamping
Peak Surge Current Capability (8 x 20 µs)
Operating Voltage Range
Model: IMxxxx160
Fault Current Rating (AIC)
UL 1449 Classification*
Model 100-2
Model 160
L-N:
80,000 Amps
Capacity
Line to Neutral
400 Volts
400 Volts
L-L:
80,000 Amps
50 ⍀ EMI/RFI Attenuation
Line to Line
800 Volts
800 Volts
L-G:
80,000 Amps
Dry Contact Rating
Line to Ground
800 Volts
400 Volts
N-G:
80,000 Amps
Response Time
Neutral to Ground
400 Volts
400 Volts
Model: IMxxxx100-2
120/208
277/480
Line to Neutral
Phase:
160,000 Amps
65 kAIC
Operating Frequency Range
47 - 63 Hz
Continuous
40 dB
125 VAC, 8A, 1.0 pf
< 0.5 ns
Operating Temperature
Phase:
100,000 Amps
Operating Humidity
800 Volts
800 Volts
L-N:
100,000 Amps
Certifications
Line to Line
1,500 Volts
1,500 Volts
L-L:
100,000 Amps
Warranty
Line to Ground
1,500 Volts
800 Volts
L-G:
N/A
800 Volts
800 Volts
N-G:
1,500 Volts
2,500 Volts
800 Volts
1,500 Volts
Neutral to Ground
+/- 15%
-45°C to +50°C
0% to 95%
UL 1449, CUL
5 Year
100,000 Amps
480
Line to Line
Line to Ground
Dimensional Diagram
* UL classifications for other voltages available
upon request.
4
Model
A
B
C
D
E
F
IMxxxY160
8
6
4
8.75
4
.31
IMxxxD160
8
6
4
8.75
4
.31
IMxxxY100-2 6
4
3
6.75
2
.31
IMxxxD100-2 6
4
3
6.75
2
.31
Transient Voltage Surge Suppression
IslaGuard® — IL Series
Electronic grade Surge Protective Device (SPD) designed to protect
electronic equipment and microprocessor-based systems from
transients on sub-distribution panels, branch panels, or equipment
located in low exposure locations.
Features
■ Surge current capacity — 25,000 to 100,000
Amps per phase
■ Sand encapsulation
■ Thermal protection
■ All mode and 2 mode protection option
■ Silver link fusing
■ Small footprint
■ 5 year warranty
■ All voltage and phase configurations
■ LED status indication and form C contact
for remote indication
Performance Technical Specifications
General Technical Specifications
Clamping
Peak Surge Current Capability (8 x 20 µs)
Operating Voltage Range
+/- 15%
UL 1449 Classification*
Model ILxxxx100
Fault Current Rating (AIC)
22 kAIC
Model
25-2
Models
50 & 100
120/208
Line to Neutral
500 Volts
500 Volts
Line to Line
800 Volts
800 Volts
Line to Ground
800 Volts
500 Volts
Neutral to Ground
500 Volts
500 Volts
120/240
Line to Neutral
500 Volts
500 Volts
Line to Line
800 Volts
800 Volts
Line to Ground
800 Volts
500 Volts
Neutral to Ground
500 Volts
500 Volts
900 Volts
900 Volts
Line to Line
1,800 Volts
1,800 Volts
Line to Ground
2,500 Volts
1,000 Volts
Neutral to Ground
1,200 Volts
1,200 Volts
Line to Ground
Operating Frequency Range
50,000 Amps
Capacity
L-L:
50,000 Amps
50 Ω EMI/RFI Attenuation
L-G:
50,000 Amps
Dry Contact Rating
N-G:
50,000 Amps
Response Time
Model ILxxxx50
Operating Temperature
Phase:
50,000 Amps
Operating Humidity
L-N:
25,000 Amps
Certifications
L-L:
25,000 Amps
Warranty
L-G:
25,000 Amps
N-G:
25,000 Amps
Phase:
25,000 Amps
L-N:
25,000 Amps
L-L:
25,000 Amps
L-G:
N-G:
480
Line to Line
100,000 Amps
L-N:
47 - 63 Hz
Continuous
40 dB
125 VAC, 8 A, 1.0 pf
< 0.5 ns
-40°C to +50°C
0% to 95%
UL 1449, CUL, CE
5 Year
Dimensional Diagram
Model ILxxxx25-2
277/480
Line to Neutral
Phase:
1,800 Volts
N/A
25,000 Amps
1,800 Volts
1,800 Volts
* UL classifications for other voltages available
upon request.
5
Transient Voltage Surge Suppression
IslaGuard® — Ordering Information
®
IslaGuard High Exposure Model Number : I H
1 2 3 6
IslaGuard® Medium Exposure Model Number : I M
How to Specify the Appropriate Model
All model numbers begin with a prefix (IH, IM, IL).
Moving from left to right, choose correct configuration
from each column for your application. Your completed
model number should look similar to the example below:
1 2 4
IslaGuard® Low Exposure Model Number : I L 1 2 5
Example Part Number: IH 120 L 200 X
1
Voltage Code
Nominal Voltage Level
2
Phase Configuration
Model
Identification
L–N
L–L
L–G
120
N/A
120
120
208
120
120
240
120
N/A
240
240
240
277
480
277
277
N/A
480
480
480
120
Phase Configuration
Single Phase 2 Wires + Gnd
(Line & Neutral)
N
Single Phase 2 Wires + Gnd
(Line & Line)
L
Single (Split) Phase
3 Wires + Gnd
S
Three Phase Wye
4 Wires + Gnd
Y
Three Phase Delta
3 Wires + Gnd
D
Three Phase Delta Hi-Leg
4 Wires + Gnd
H
Three Phase Wye w/no Neutral
3 Wires + Gnd
X
4
Surge Capacity (Medium Exposure)
160 kA
Model
Identification
Model
Identification
400 kA
L–N
L–G
N–G
200
200
200
400
Model
Identification
L–N
200
L–G
N–G
N/A
200
200 kA
L–N
L–G
N–G
100
100
100
Surge Capacity Per Phase
(L-N + L-G)
100 kA
Model
Identification
L–G
N–G
100
N/A
100
100-2
6
Options
Option
Model
Identification
Rotary Disconnect
R
L–G
N–G
L–N
L–G
N–G
Surge Counter
C
80
80
80
50
50
50
NEMA 3R Enclosure
3R
100-2
100
200
100 kA
L–N
5
Surge Capacity (Low Exposure)
160
200-2
L–N
100 kA
50 kA
L–N
L–G
N–G
L–N
100
N/A
100
25
50
L–G
N–G
25
25
200 kA
25-2
L–N
L–G
N–G
25
N/A
25
Recommended Connections
6
Surge Capacity Per Phase
(L-N + L-G)
200 kA
Other voltages available, please consult factory.
Surge Capacity Per Phase
(L-N + L-G)
3
Surge Capacity (High Exposure)
NEMA 4 Enclosure
4
NEMA 4X Enclosure
4X
Transient Voltage Surge Suppression
DRS Series
Modular Surge Protective Device (SPD) designed to be easily installed in existing
AC panelboards and control panels using standard DIN rail mounting brackets.
These devices offer both normal and common surge protection up to
40 kA per phase.
Features
■ Effectively handles high-energy transients
on TT, TN-C, TN-S and TN-C-S three-phase
power systems
■ SPD rated Type 2 in accordance with
EN 61643-11; Class I & II in accordance
with IEC 61643-1
■ Built-in thermal components disconnect
SPD from the power source to avoid
thermal runaway conditions
■ MOV only or MOV+Gas Tube models
available
■ Fast response time, high surge current
capability, low voltage protection levels
■ Visual inspection window on each module
indicates status
■ 3-pole terminal provides remote status
monitoring
■ DIN rail mounting and plug-in module
design allow for easy installation,
maintenance and replacement of
surge element
■ 5 year warranty
How to Specify the Appropriate Model
Example: DRS 120 3 1 Q
Nominal Voltage
(Un) (XXX)
# of Metal Oxide Varistor Modules*
(X)
# of Gas Tube Modules**
(X)
Higher Rated Voltage***
(Optional)
120
0
0
Q
230
1
1
240
2
277
3
346
4
*MOV modules are typically one module per phase and may be wired L-N, L-G or N-G.
**Gas Tube modules typically used in the N-G mode for type TT grounding systems.
***Certain applications require higher rated components in order to survive frequent
voltage rises, in this case order a unit with a “Q” at the end of the part number.
480
600
Replacement modules available: Order DRS + Un + M (for MOV) or G (for Gas Tube)
Performance Technical Specifications
DRS12031
DRS23031
DRS27731
DRS34631
Electrical
Characteristics
System Voltage
Type of Network
120/208,
230/400, 220/380, 277/480,
127/220 VAC
240/415 VAC 254/440 VAC
TT-TN
346/600 VAC
TT-TN
TT-TN
TT-TN
Modes of Protection L-N; N-PE
L-N; N-PE
L-N; N-PE
L-N; N-PE
Nominal Voltage
Un–120 V
Un–230 V
Un–277 V
Un–346 V
Rated Voltage
(MCOV)
Uc–150 V
Uc–320 V
Uc–320 V
Uc–420 V
Nominal Discharge
Current (8 x 20 µs)
1n–20 kA
Test Standards
EN 61643-11
Type 2
IEC61643- 1:1998-02
Class II
Mechanical
Characteristics
Dimensions (Length x Width x Height)
70.8mm x 90.5mm x 68mm
I/O Connections
By Screw Terminal: 4-25 mm2
By Connection Bus
MOV Encapsulation Material
Disconnection Indicator
1n–20 kA
1n–20 kA
1n–20 kA
Status Monitoring
Mounting
Maximum
Discharge Current
Imax–40 kA
Imax–40 kA
Imax–40 kA
Imax–40 kA
Voltage Protection
Level
Up–1.2 kV
Up–1.6 kV
Up—1.6 kV
Up–2.0 kV
Response Time
TS–25 ns
TS–25 ns
TS–25 ns
TS–25 ns
95%
95%
95%
95%
Risol
> 103 MV
Risol
> 103 MV
Risol
> 103 MV
Risol
> 103 MV
Relative Humidity
Isolation
Resistance
Operation Temperature Range
Degree of Protection
Disconnection Device
Housing Material
Epoxy Resin
Mechanical Indicator
Remote Alarm Terminals
Symmetrical Rail (EN50022/DIN46277-3)
-40°C to +85°C
IP 20
Thermal Cutoff System
ABS/PA UL94V0
7
Transient Voltage Surge Suppression
Edco EMC-240B
120/240 VAC Heavy Duty (Parallel)
The Edco EMC 240B surge suppressor is designed to protect AC distribution
panel circuits or 120 V power supplies feeding sensitive electronic equipment.
Electrically, the unit incorporates MOV and thermal fusing technology. The
Edco EMC 240B is designed to be installed in parallel on standard single phase
120 VAC (L,N,G) circuits.
Features
■ Fast response time
■ Operational status indicators
■ 40,000 Amps per phase capacity
■ UL 1449 listed and OWHX listed
■ Failsafe and fused
■ 5 year warranty
1449
General Technical Specifications
Operating Voltage
120/240 VAC
Clamping Voltage
395 VAC
Fault Current Rating (AIC)
42 kAIC
Operating Current
Total Peak Surge Current
EMI Attenuation (100 kHz to 100 MHz)
SPD Technology
> 40 dB
Metal Oxide Varistors (MOVs)
Modes of Protection
Line-to-Line,
Line-to-Neutral
NA, Parallel
80 kA (8 x 20 µs)
Status Indication
Power On & MOVs functional
47-63 Hz
Connection Type
Wire Leads
Operating Frequency
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
4.6H x 2.2W x 2.8L
Weight
Certifications
13.5 oz
UL 1449, Suppressor/
OWHX Arrester
Edco FAS-120AC
120 VAC Medium Duty (Parallel) AC-Hardware
The Edco FAS-120AC surge suppressor is designed to protect AC distribution
panel circuits or 120 V power supplies feeding sensitive electronic equipment.
Electrically, the unit incorporates MOV and thermal fusing technology. The Edco
FAS-120AC is designed to be installed in parallel on standard single phase 120
VAC (L,N,G) circuits.
Features
■ LED indicator
■ Compact size
■ Fast response time
■ Liquid tight conduit fitting
■ Thermal fuse
■ UL 1449 listed
■ L-G, L-N, & N-G protection
■ 5 year warranty
General Technical Specifications
120 VAC
SPD Technology
Clamping Voltage
325 VAC
Modes of Protection
Operating Current
NA, Parallel
Operating Voltage
Total Peak Surge Current
Line-to-Neutral,
Line-to-Ground, Neutral-to-Ground
15.5 kA (8 x 20 µs)
Status Indication
Power On & MOV Functional
47-63 Hz
Connection Type
Wire Leads
Operating Frequency
EMI Attenuation (100 kHz to 100 MHz)
8
Metal Oxide Varistors (MOVs)
> 25 dB
Operating Temperature
-40°C to +85°C
Dimensions (Inches)
Weight
Certifications
2.5H x 1.5W x 3.0L
4.2 oz
UL 1449
Filtering/Line Conditioning
Filtering/Line Conditioning — Product Selection Guide
Find your application in the left column.
Then look across for the appropriate product.
PRODUCTS
APPLICATIONS
Islatrol®
IE
Series
Programmable Logic
Controllers
Control Panels
(AC Power)
Various OEM
Equipment
Home
Entertainment/Office
Islatrol®
IC+/LRIC+
Series
Islatrol®
SP-6TVN
Series
Islatrol®
RM
Series
*
*
*
*
*
*
AC Rack Equipment
9
Filtering/Line Conditioning
Islatrol® IE Series
Active Tracking Filter®
Series connected DIN/flange mount high-frequency noise filter/surge
suppressor. Ideal applications include critical industrial loads drawing
up to 20 Amps of continuous current. Typical applications include any
microprocessor-based products, including industrial PLCs, OEM
applications, and motion control systems.
Features
■ Multi-staged design, combining a unique
hybrid clamping network with the active
tracking technology of the Islatrol ® family
■ LED status indication and form C contact
for remote indication
■ DIN mountable enclosure
■ Surge current capacity — 45,000 Amps
■ UL 1449, 1283, CUL recognized, CE
■ Transient protection in all modes: line
to neutral, line to ground, and neutral
to ground
Performance Technical Specifications General Technical Specifications
Ordering Information
UL 1449 Surge Voltage Rating
Voltage*
MCOV
Continuous Current
Model
120V Normal Mode
330 Volts
120 Volt
150 VRMS
120 V
3 Amps
IE-103
120V Common Mode
400 Volts
240 Volt
275 VRMS
120 V
5 Amps
IE-105
240V Normal Mode
600 Volts
Line Frequency
47 - 63 Hz
120 V
10 Amps
IE-110
240V Common Mode
800 Volts
Connection
Terminal
120 V
20 Amps
IE-120
Peak Surge Current Capability (8 x 20 µs)
Mounting Type
Line to Neutral
Weight
15,000 Amps
Line to Ground
15,000 Amps
Response Time
Neutral to Ground
15,000 Amps
Normal Mode
Total
45,000 Amps
Frequency Response (Forward-Reverse)
Normal Mode
Common Mode
100 kHz to 50 MHz - 90 dB Min
5 MHz to 50 MHz - 60 dB Min
Typical Category A Ringwave (6 kV, 200 A, 100 kHz)
Normal Mode/Common Mode
3 Amp
1 V/300 V
5 Amp
0.7 V/292 V
10 Amp
0.7 V/300 V
20 Amp
0.7 V/300 V
Typical Category B Ringwave (6 kV, 500 A, 100 kHz)
Normal Mode/Common Mode
10
■ 10 year warranty
3 Amp
178 V/300 V
5 Amp
162 V/291 V
10 Amp
153 V/300 V
20 Amp
200 V/300 V
DIN/Flange
< 3 lbs
Voltage*
240 V
Common Mode
Operating Temperature
Model
3 Amps
IE-203
< 0.5 ns
240 V
5 Amps
IE-205
< 5 ns
240 V
10 Amps
IE-210
-40°C to +45°C
240 V
20 Amps
IE-220
Derate Linearly to 60% at +70ºC
Operating Humidity
Continuous Current
* All voltage configurations are single phase - 2 wire + gnd.
0% to 95%
Dimensional Diagram
Filtering/Line Conditioning
Islatrol™ IE Series
Active Tracking Filter™
System Design
Shunt Absorbing Components
line side sine wave tracking circuitry
Shunt Absorbing Components
load side sine wave tracking circuitry
Finger Safe Terminals
IEC 998 approved terminals
Form C Relay Contacts
normally open and normally closed dry
contact for remote status monitoring
Unit Status Indicator
green LED monitors the operational
status of the Elite Series
MOV Array
high-energy surge current diversion
array providing transient protection
line to neutral, line to ground, and
neutral to ground
Series Blocking Inductor
voltage blocking current
soothing inductor
Pulse Capacitor
high-frequency noise absorption
DIN Rail Mountable
mounts to standard 35 mm
industrial DIN rail; rotates 90°
for mounting flexibility
Connection Diagram
11
Filtering/Line Conditioning
Islatrol® IC+/LRIC+ Series
Active Tracking Filter®
Series connected high-frequency noise filter with transient protection. Offers
the flexibility of either receptacle/line cord connection or hard-wired connection
to critical loads (up to 30 Amperes). Applications include industrial or office
equipment, computers placed in harsh environments.
Features
■ Typically reduces normal mode transients
to +/-2 volts
■ LED power indication
■ UL 1283, CSA recognized
■ Surge current capacity — 45,000 Amps
■ 10 year warranty
■ Transient protection in all modes: line
to neutral, line to ground, and neutral
to ground
1283
MCOV
Typical Category A Ringwave (6 kV, 200 A, 100 kHz)
120 Volt
150 VRMS
Model
Normal
Common
240 Volt
275 VRMS
IC+102 / LRIC+102
1.0 / 0.9
302 / 287
Line Frequency
47 - 63 Hz
IC+105 / LRIC+105
0.7 / 0.8
292 / 307
IC+107 / LRIC+107
0.7 / 0.7
302 / 293
IC+115 / LRIC+115
0.7 / 0.7
304 / 306
IC+130 / IC+202
0.5 / 1.1
306 / 536
IC+205 / IC+207
1.5 / 0.8
628 / 616
IC+215 / IC+230
0.6 / 0.9
572 / 566
Response Time
Normal Mode
< 0.5 ns
Common Mode
<5ns
Operating Temperature
-40°C to +45°C at Full Load
Derate Linearly to 60% at +70ºC
Operating Humidity
0% to 95%
Model
Normal
Common
Peak Surge Current Capability (8 x 20 µs)
IC+102 / LRIC+102
178 / 188
302 / 285
Line to Neutral
15,000 Amps
IC+105 / LRIC+105
162 / 191
291 / 300
Line to Ground
15,000 Amps
IC+107 / LRIC+107
173 / 190
300 / 298
Neutral to Ground
15,000 Amps
IC+115 / LRIC+115
153 / 149
307 / 309
Load Surge Current Rating
IC+130 / IC+202
241 / 302
299 / 532
10 mSec
5 x Nominal
IC+205 / IC+207
378 / 336
594 / 596
1 sec
3 x Nominal
IC+215 / IC+230
272 / 342
548 / 578
10 sec
2 x Nominal
Packaging
• High Impact Plastic Case
• Vacuum Impregnated Magnetics
• Epoxy Encapsulated
Frequency Response (Forward-Reverse)
Normal Mode
Common Mode
12
Typical Category B Ringwave (6 kV, 500 A, 100 kHz)
100 kHz to 50 MHz - 90 dB Min
5 MHz to 50 MHz - 60 dB Min
System Design
Series Blocking Inductors
voltage blocking current
smoothing inductors
Shunt Absorbing Components
sine wave tracking circuitry
MOV Transient Protection
high-energy transient
protection line to neutral,
line to ground,
neutral to ground
Pulse Capacitor
high-frequency noise absorption
Note: All measurements in volts. IEEE test results with
no AC applied. Normal mode—L1-N or L1-L2;
Common mode—L-G, N-G or L1-G, L2-G.
Connection Diagram
Filtering/Line Conditioning
Islatrol® IC+/LRIC+ Series
Active Tracking Filter®
Ordering Information
Dimensional Diagram
120 VAC Models with barrier strip at input and output/with wire leads at input and output (WL)
F
B
Model
Rated
Output
(Amps)
Case
Dimensions (In)
AxBxC
Mounting Flange
Dimensions (In)
DxExFxG
Screw
Size
Weight
(lbs)
IC+102 / IC+102WL
2.5
4 x 2.88 x 1.81
4.38 x 2.12 x 5.31 x 0.19
#6
1.0
IC+105 / IC+105WL
5.0
4 x 2.88 x 1.81
4.38 x 2.12 x 5.31 x 0.19
#6
1.3
IC+107 / IC+107WL
7.5
4.75 x 4.75 x 2.35
5.25 x 3.50 x 6.25 x 0.19
#6
2.0
IC+115 / IC+115WL
15
6.25 x 4.75 x 2.35
6.75 x 3.50 x 7.75 x 0.19
#8
3.5
IC+130 / IC+130WL
30
7.75 x 4.75 x 2.35
8.25 x 3.50 x 9.00 x 0.19
#8
6.0
A
C
D
M
DIMOUN
EN TING
SIO
NS
G
E
120 VAC Models with 5 foot line cord and single NEMA 5-15 receptacle
Model
Rated
Output
(Amps)
Case
Dimensions (In)
AxBxC
Mounting Flange
Dimensions (In)
DxExFxG
Screw
Size
Weight
(lbs)
LRIC+102
2.5
4.5 x 3.0 x 1.88
N/A
N/A
1.3
LRIC+105
5.0
4.5 x 4.5 x 2.38
N/A
N/A
2.0
LRIC+107
7.5
6.0 x 4.5 x 2.38
N/A
N/A
2.3
LRIC+115
15
7.5 x 4.5 x 2.38
N/A
N/A
4.0
240 VAC Models with barrier strip at input and output/with wire leads at input and output (WL)
F
B
Model
Rated
Output
(Amps)
Case
Dimensions (In)
AxBxC
Mounting Flange
Dimensions (In)
DxExFxG
Screw Weight
Size
(lbs)
IC+202 / IC+202WL
2.5
4 x 2.88 x 1.81
4.38 x 2.12 x 5.31 x 0.19
#6
1.3
IC+205 / IC+205WL
5.0
4.75 x 4.75 x 2.35
5.25 x 3.50 x 6.25 x 0.19
#6
2.0
IC+207 / IC+207WL
7.5
6.25 x 4.75 x 2.35
6.75 x 3.50 x 7.75 x 0.19
#8
3.3
IC+215 / IC+215WL
15
7.75 x 4.75 x 2.35
8.25 x 3.50 x 9.00 x 0.19
#8
5.8
IC+230 / IC+230WL
30
7.75 x 4.75 x 2.35
8.25 x 3.50 x 9.00 x 0.19
#8
6.0
A
C
D
M
DIMOUN
EN TING
SIO
NS
G
E
Islatrol® E Series
F
B
A
Active Tracking Filter® for DC Voltages
C
Provides continuous sine wave Active Tracking® filtration, normal mode (line to line
or line to neutral) for protection from spikes, transients, and noise on AC power line.
M
DIMOUN
EN TING
SIO
NS
D
G
E
Available in either hardwired, printed circuit board mount, wire lead mount or single
receptacle/line cord configurations, single phase or three phase, 50/60 Hz.
Ordering Information
35 VDC, printed circuit board mount or with wire leads at input and output
(Add “WL” suffix in place of “PC” suffix.)
Model Number
E-025PC
E-05PC
E-1PC
Amperes
0.25
0.50
1.00
Weight (lbs)
1
1
1
100 VDC with barrier strips at input and output
Model Number
E-1 (only 35 VDC)
E-2
E-5
E-7
E-15
E-30
E-50
E-100
Amperes
1.0
2.5
5.0
7.5
15.0
30.0
50.0
100.0
Weight (lbs)
3
3
3
3
9
9
10
15
Islatrol® Active Tracking Filters® carry a 10 year warranty
13
Filtering/Line Conditioning
Islatrol® — SP-6TVN
Industrial Strength Surge Suppression (Series)
The Islatrol® SP-6TVN is an industrial-strength surge suppression/filtering
device that plugs into a standard duplex receptacle. It features uniquely
designed repositionable outlets for easy installation behind desks and
other furniture. It protects your sensitive home or office equipment,
including TVs, home theaters, satellite dishes, computers, printers,
copiers, and fax machines, from damaging power disturbances traveling
through your wiring into your electrical outlets.
Features
Repositionable Outlets
■ Plugs into standard 120 V, 15 Amp
electrical outlet
■ Perfect for tight spaces, behind furniture
and appliances
■ Total peak surge current capacity of
39,000 Amps
■ Intelligent monitoring against improper
wiring/grounding
■ Cables for telephone, video, and
data connections
■ 60 dB maximum high frequency
■ Operational indicator lamp
■ Repositionable outlets rotate to
accommodate available space
■ 5 year limited warranty
General Technical Specifications
AC Power Protection
Nominal Operating Voltage
120 VAC, Single Phase
Operating Voltage Range
120 VAC +/- 10%
Operating Frequency Range
265 V
Common Mode
290 V
ANSI/IEEE C62.41 Cat B Ringwave (6 kV, 500 A, 100 kHz)
Normal Mode
275 V
Common Mode
290 V
47 — 63 Hz
Rated Output (Amps)
15 Amperes
ANSI/IEEE C62.41 Category
Connection Type
ANSI/IEEE C62.41 Cat A Ringwave (6 kV, 200 A, 100 kHz)
Normal Mode
Category A & B
(6) 5-15R Receptacles and
5-15P Plug
Phase Configuration
Size
Enclosure
Weight
Modes Of Protection
Indication of Suppression Status
Response Time
Certifications
2 Wire + Gnd
7.5 x 4.75 x 1.75 (Inches)
Frequency Response
Normal Mode
2.0 lbs (0.9 kgs)
Low Voltage Protection
Video 1 & 2
L — N, L — G, N — G
Status Indicator
< .5 ns Normal Mode
Connection Type
CablesProvided
5 Year
130 VAC
Protection Level
Clamping Voltage (DC)
14
Phone
Network
Type “F”
Type RJ-11
Type RJ-45
6'(2x)Type“F”
6'Ends
6'RJ-11Male
6'Ends
6'RJ-45Male
Ends
5 kA
(8 x 20 µs)
2 kA
(10 x 1000 µs)
3 kA
(8 x 20 µs)
UL 1449 Listed
Capacitance
Maximum Continuous Operating Voltage (MCOV)
Line to Neutral
40 dB Maximum, forward/reverse, 5 MHz to 50 MHz
High Impact Plastic
Peak Surge Current
Warranty
60 dB Maximum, forward/reverse, 100 kHz to 50 MHz
Common Mode
Attenuation
Peak Surge Current (8 x 20 ms)
Line to Neutral
13,000 Amps
Line to Ground
13,000 Amps
Neutral to Ground
13,000 Amps
Total
39,000 Amps
<12 pf
<50 pf
<70 pf
L-G
T-R, T-G, R-G
L-G (8 Lines)
145 V
270-350 V
30 V
1 dB @ 2 Ghz
N/A
N/A
Filtering/line Conditioning
islatrol® — rM Series
120 VAC Rackmount
This line of A­C surge protectors is ideal for protecting the power feeding
valuable rack equipment. A­ll models provide ten protected outlets on the
back and two protected convenience outlets on the front. This series provides
40,000 A­mps of surge protection and up to 60 dB of high-frequency noise
filtering. Status LEDs indicate the correct power is coming to the unit, whether
Model shown: rM-115-10 rM
the unit is properly grounded and whether the surge components are still in
tact. Units are available with an optional digital meter, mounted on the front of the
unit, that will monitor the voltage, current and power of the protected equipment.
Features
n 40 kA­ surge protection
n Digital meter
n 60 dB max noise filtering
n Optional twist lock plug
n 15 & 20 A­ models available
n 1 year warranty
n Power, ground and surge status indicators
general Technical Specifications
Voltage
amperage
Plug (NEMa)
receptacles (NEMa)
digital Meter
locking Plug
RM-115-10RM
Model
120 V
15 A­
5-15P
5-15R
Yes
No
RM-120-10RM
120 V
20 A­
5-20P
5-20R
Yes
No
rackmount aC Power Protection
Rated Voltage
120 V
Rated Current
15 A­ & 20 A­
Peak Surge Current
Response Time
EMI/RFI Filtering
LED Indicators
Digital Meter
(Optional)
Input Power
15 A­ Models
20A­ Models
20 kA­/mode, 40 kA­/phase
<5 ns
60 dB Max
Green-Power on
Green-Ground OK
Green-Surge Circuit OK
Voltage A­mps, Watts, VA­, Hz, PF,
Kwh, and Clock
Output Receptacles
15A­ Models
20A­ Models
Thermal Protection
Overcurrent Protection
Dimensions
Certifications
Warranty
Front- (2) NEMA­ 5-15R
Back- (10) NEMA­ 5-15R
Front- (2) NEMA­ 5-20R
Back- (10) NEMA­ 5-20R
Thermal Protected MOVs
Circuit
1.75”H x 19”W x 3.8”D (1U)
UL1449
1 Year
SJT 14/3C Power Cord (15 ft)
with NEMA­ 5-15P Plug
SJT 12/3C Power Cord (15 ft)
with NEMA­ 5-20P Plug
NEMA­ L5-20P Plug- Optional
15
Data/Signal Line Protection
Data/Signal Line Protection — Product Selection Guide
Find your application in the left column.
Then look across for the appropriate product.
PRODUCTS
APPLICATIONS
Transmitters
Telephone
Industrial
Communications
Signaling
Circuits
Programmable
Logic Controllers
(I/O) Circuits
Control Panels
(Low Voltage)
Communication
Rack Equipment
Video Equipment
Video Rack
Equipment
Water/
Wastewater
Instrumentation
16
Edco
DRS
Series
Edco
PC642
Series
Edco
PHC
Series
Edco
RJA/RJD
Series
Edco
RM-CAT6
Series
Edco
SLAC
Series
Edco
SS64/65
Series
Edco
CX
Series
Edco
RM-CX06
Series
Data/Signal Line Protection
Edco DRS (DC) Series
DIN Rail Protection
The Edco DRS (DC) Series is a DIN rail mountable, single-pair surge suppression
module implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components. In
addition, sneak currents are mitigated with resettable fuses (PTCs). The PTCs
increase resistance several orders of magnitude when over-currents exceed
safe levels. A normal state resumes when over-currents are removed. The ability
to self-restore in this manner significantly increases suppressor performance
and survivability.
The Edco DRS (DC) Series mounts onto a standard 35 mm industrial DIN rail. There
are three “Field Side” and three “Electronics Side” screw terminals. One is reserved
for a shield. Three electrically tied ground terminals are provided for grounding the
Edco DRS Series unit to Building-Approved Ground. Shield is isolated from ground.
For a 2-terminal version without a shield, order the Edco DRS-XXX-2.
Features
Low-voltage data surge protection
Easy installation
Three-stage hybrid protection
Fits standard 35 mm DIN rail
Sneak/fault current protection with
resettable fuses — PTCs
Fast response time
< 1 nanosecond
Low profile packaging
5 year warranty
UL 497B listed *
General Technical Specifications
Part
Number
Maximum
PeakSignal
Voltage
Nominal
Breakdown
Voltage
Surge
1p10x1000µs
Current
Dimensional Diagrams
PeakCurrent
8x20µs
Waveform
Typ
Cap
(pf)
Maximum
Continuous
Current(ma)
Nominal
Series
Resistance
DRS-008
6
8
>100
10 kA
1500
150
5 Ohms
DRS-015
12
15
>100
10 kA
1500
150
5 Ohms
DRS-232
15
22
>100
10 kA
1500
150
5 Ohms
DRS-030
24
30
>100
10 kA
1500
150
5 Ohms
DRS-036
30
36
>100
10 kA
1500
150
5 Ohms
DRS-043
35
43
>100
10 kA
1500
150
5 Ohms
DRS-050
43
50
>100
10 kA
1500
150
5 Ohms
DRS-060
52
60
>100
10 kA
1500
150
5 Ohms
*DRS-175
**DRS-130
200
170
250
200
>10
>10
8 kA
8 kA
1500
1500
150
5000
DRS-XXX
5 Ohms
None
*NOT UL 497B listed
**Warning!! DRS-130RMS is for Discrete Signal Use Only. Do not use DRS-130RMS on 120 VAC Power Lines. This
unit is a non-hybrid, MOV design, rated above 5 A operational current and can withstand greater than eight
occurrences of a 10 kA 8 x 20 µs waveform, and greater than 1000 occurrences of a 200 A 10 x 1000 µs waveform.
DRS-XXX-2
(2 terminal version)
17
Data/Signal Line Protection
Edco PC642 Series
Zone/Loop/Data
The Edco PC642 Series surge suppressor is a two-pair (four-wire) module
implementing three-stage hybrid technology. This module addresses
over-voltage transients with gas tubes and silicon avalanche components. In
addition, sneak and fault currents are mitigated with resettable fuses (PTCs).
The PTCs increase resistance several orders of magnitude when over-currents
exceed safe levels. A normal state resumes when over-currents are removed.
The ability to self-restore in this manner significantly increases suppressor
EDCO PCB1B BASE SOLD SEPARATELY
performance and survivability.
The Edco PC642 card edge module is gold-plated, double-sided, and is
designed to mate with the Edco PCB1B gold-plated female terminal connector.
When snapped together, the data circuits “pass thru” the protector in a serial
fashion from the four “Field Side” terminals to the four “Electronics Side”
terminals. Terminals 1 or 10 of the Edco PCB1B must be attached to BuildingApproved Ground per Edco Technical Bulletin # 2015.
Features
■ Three-stage hybrid protection
■ Fast response time
■ Sneak/fault current protection
■ Requires Edco PCB1B base
■ Resettable fusing — PTCs
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Low capacitance option
■ 5 year warranty
■ Plug-in module
General Technical Specifications
Ordering Information
Maximum Continuous
Operating Voltage (MCOV)
5, 12, 18, 24, 30, 36,
43, 52, (60-250) VDC
Clamping Voltage
8, 15, 20, 30, 36, 43,
50, 60, 300 VDC
RS423, Token Ring: PC642C-008LC & PCB1B
0.15 A
E-NET, 10 BASE T: PC642C-030LC & PCB1B
Operating Current
Peak Surge Current
4–20ma:
PC642C-020 & PCB1B
PC642C-036 & PCB1B
GDT, SAD, w/Series PTC
Terminal block
w/compression lugs
Terminals accept up to 10 AWG
Operating Temperature
Dimensions (Inches)
Certifications
RS232:
PC642C-008LC & PCB1B
< 0.1 dB at 20 MHz
SPD Technology
Weight
RS485, RS422:
0 to 20 MHz
Insertion Loss
Connection Type
APPLICATION:
10 kA (8 x 20 µs)
Frequency Range
-40°C to +85°C
2H x 1W x 2.5L
(PC642 + PCB1B Base)
1 oz
UL 497B
Caution: The hybrid design of this product includes
series resistance. Do not place this product in
service on any signal line capable of supplying
more than 150 milliamperes continuously.
18
Terminal Assignments
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
How to Specify the Appropriate Model
Data/Signal Line Protection
Edco PHC Series
Two-Pair Signaling Circuit Protector (Modular)
The Edco PHC Series is designed to protect two pairs of wires specifically for
alarm and security systems where operating currents can be as high as 5 Amps.
Electrically, the Edco PHC Series is a rugged series hybrid implementing a
staged complement of MOVs, copper wound inductors and Silicon Avalanche
Diodes. This design reduces series resistance to 0.2 Ohms per pair. These
products are intended to mate with an Edco PCB1B gold-plated female
terminal connector.
The Edco PHC modules plug into a base assembly (Edco PCB1B). The base
assembly can be mounted to any flat surface and should be located as close as
practical to the protected equipment. Terminal 1 and/or terminal 10 should be
connected to Building-Approved Ground with 12 or 10 gauge solid wire.
Features
EDCO PCB1B BASE SOLD SEPARATELY
■ Three-stage protection
■ Continuous current up to 5 Amps
■ Differential protection
■ UL 497B listed
■ Common mode protection
■ Requires Edco PCB1B base
■ Plug-in module
■ PC642PTU (Pass Thru Unit)
available for troubleshooting
■ Automatic recovery
■ 5 year warranty
■ Fast response time
Terminal Assignments
General Technical Specifications
Operating Voltage
12, 18, 24, 36, 52, 60, 120 VDC
Clamping Voltage
15, 20, 30, 43, 60, 70, 150 VDC
Operating Current
How to Specify the Appropriate Model
5A
Peak Surge Current
10 kA (8 x 20 µs)
Frequency Range
0 to 10 MHz
Insertion Loss
< 0.1 dB at 10 MHz
SPD Technology
Connection Type
Ordering Information
MOV, SAD, w/Series Inductor
Terminal block
w/compression lugs
Terminals accept up to 10 AWG
Operating Temperature
Dimensions (Inches)
-40°C to +85°C
3.7H x 1.75W x 2.375L
(PHC + PCB1B Base)
Weight
DO NOT daisy chain grounds. NOT intended for shield
termination. Install ground in accordance with all
applicable codes.
Dimensions
8 oz
Certifications
UL 497B
Applications Part Number
24V Horn, Strobe, Bell:
70V Speaker Lines:
PHC-043 & PCB1B
PHC-SP70 & PCB1B
19
Data/Signal Line Protection
Edco RJA-RJD Series
RJ-45 Telephone/Data
The Edco RJA and Edco RJD Series are four pair telephone/data line
protectors that implement advanced two stage hybrid design. These units
address over-voltage transients with silicon breakover devices, while sneak
and fault currents are mitigated with PTC technology, which consists of solid
state resettable fuses.
The Edco RJA and Edco RJD Series incorporate RJ-45 female jacks in and out.
The Edco RJA voltage clamp is set for C.O. Trunks and Analog Telephone
Extensions (with ring in voltage), and the Edco RJD voltage clamp is set for
Digital Extensions (no ring in voltage).
Features
General Technical Specifications
■ Tip and ring to ground protection
■ Solid-state resettable fuses-PTCs
■ CAN/CSA C22.2, No. 226-92 Compliant
■ Silicon breakover technology
■ UL 497A listed
■ Low capacitance
■ 4 pair protection
■ Line-to-line protection
■ 5 year warranty
Installation
Ordering Information
Operating Voltage
48, 220 VDC
Analog Phone
RJA-45
Clamping Voltage
55, 280 VDC
Digital Phone
RJD-45
Operating Current
0.15 A
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
Connection Type
Operating Temperature
Dimensions (Inches)
Weight
Certifications
20
■ <1 nanosecond response time
200 A (10 x 1000 µs)
0 to 50 MHz
< 0.1 dB at 50 MHz
Silicon Breakover
Devices w/Series PTC
RJ-45 Jacks
-40°C to +85°C
1.0H x 2.5W x 4.25L
3 oz
UL 497A, CUL
The Edco RJA and Edco
RJD Series are intended
for indoor use only
and shall be employed
on the equipment side
of a listed primary
telephone protector.
Data/Signal Line Protection
Edco RM-CAT6-16POE
CAT6-16POE Channel Rackmount
The Edco RM-CAT6-16POE is a 16-channel high-speed data line protector that
utilizes a three-stage hybrid design technology. This unit addresses high-energy
voltage transients that can damage expensive computer equipment. Ideal for
Power-Over-Ethernet (POE) protection on network switches and hubs, the Edco
RM-CAT6-16POE is easily mounted in close proximity to the protected equipment.
Features
Exceeds category 6 transmission values
Low insertion loss
Three stage hybrid
Compact 1U rack size
1 year warranty
Meets Power-Over-Ethernet (POE)
requirements
General Technical Specifications
Operating Voltage
57 V
Clamping Voltage
68 V
Transmission Speed
Frequency Range
Operating Current
10 Mbps,
100 Mbps, 1,000 Mbps
0-250 MHz
0.15 A
SPD Technology
2-Port Series
SPD Technology
GDT, SAD, W/Series PTC
Modes of Protection
Signal High-Low,
Signal High-Ground,
Signal Low-Ground
Peak Surge Current
10 kA (8 x 20 µs)
Insertion Loss
<0.1 dB
VSWR
<1.2
Operating Humidity
0-95% Non-Condensing
Operating Temperature
Input Connection Type
RJ-45
Output Connection Type
RJ-45
Mounting
Enclosure Type
Dimensions
Rackmount
Painted Steel
1.75Hx19Wx6.3D
Weight
Warranty
5.5 lbs
1 Year
-40°C to +85°C
Edco CX-HFN Series
High Frequency Coax Protector — N-Type
The Edco CX-HFN surge protectors are designed to protect sensitive electronic
equipment from damage due to excessive voltage or currents generated by
lightning or static build-up.
The Edco CX-HFN offers low signal loss at frequencies up to 4 gigahertz. The unit
also has a replaceable protection cartridge (CX-RC). The Edco CX-HFN
accommodates both bulkhead mount and stud mount. The input and output
connections are interchangeable.
Features
Low signal loss
5 year warranty
General Technical Specifications
Ordering Information
Operating Voltage
130 VDC
Insertion Loss
Clamping Voltage
(DC Spark Over Voltage)
150 VDC
SPD Technology
Operating Current
Peak Surge Current
Connection Type
1A
10 kA (8 x 20 µs)
Maximum Power
10 Watts
Impedence
50 Ohms
Frequency Range
< 0.3 dB to 0.5 dB 2 to 3 GHz
Operating Temperature
Dimensions (Inches)
Weight
Gas Discharge Tube (GDT)
CX-HFN-FF (Female–Female)
CX-HFN-FM (Female-Male)
N-Type
-30°C to +85°C
1.25H x .875W x 2.5L
4 oz
0 to 4 GHz
21
Data/Signal Line Protection
Edco SLAC Series
AC Power/Signal
The Edco SLAC Series suppressor was specifically designed to protect electronic
instruments used by the water/wastewater industries. It combines hybrid AC
power protection and signal line protection in a NEMA-4X polycarbonate case.
The AC power suppressor can supply up to 1875 Watts and has a 15 Amp
replaceable fuse to prevent overloading of the protective elements. A “Power
ON” LED provides visual indication that power is applied to instruments. Signal
line protection is accomplished by the Edco PC642 Series available in a variety
of voltage clamps. Signal current can be monitored by reading the voltage
across the 10 V, 1% resistors (TP1 & TP2 or TP3 & TP4). All leads going to the
Edco SLAC board are terminated by quick disconnect or barrier block
connectors to facilitate easy removal for service or replacement.
Features
Optional twist lock plug lightning & surge
suppression for AC power and low-voltage
signal lines
Test jacks for signal line monitoring
Series hybrid AC suppressor/filter
Optional stainless steel or fiberglass
enclosure
Plug-in protection module
“Power ON” indicator
5 year warranty
15 Amp replaceable fuse
General Technical Specifications
AC Power
Standard Enclosure
Optional Enclosure
Technology
NEMA-4X
NEMA-4X
Glass-Filled Polycarbonate Base
Stainless Steel or Fiberglass
Cover Molded in Clear Polycarbonate
Continuous Hinge
Knockouts for 1/2" and 3/4" hubs
Nominal Outside Dimensions (Inches)
H=10, W=8, D=4
Three-Stage Series Hybrid
Input Voltage
120 VAC 50/60 Hz
Output Current
15 Amps Max.
Response Time
<5 Nanoseconds
Maximum Surge Current (8x20 µs)
10 kA
Occurrences at 500 Amps
Parameter
Normal Mode
(L-N)
>50
Common Mode
(L-G) (N-G)
Bosses for 6 BZ x 3/8" Self-Tapping Screws
Maximum Protection—Total Insulation
Corrosion Resistant
Resists Temperature of 248°F
IEEE 587 CAT A Ring*
172 V
280 V
Flammability Rating UL94-5V
IEEE 587 CAT B Ring*
205 V
280 V
IEEE 587 CAT B Impulse* 330 V
360 V
Nominal Outside dimensions (Inches)
H= 6.89, W=6.89, D=2.95
How to Specify the Appropriate Model
*Measured from zero volts, 90° Phase angle
General Technical Specifications
Signal Line
Technology
Peak Surge Current
Response Time
Voltage Clamp (customer selected)
Series Resistance
22
Series Hybrid
10 kA
<1 Nanosecond
8–200 Volts
5 ⍀ (Typical)
Ordering Information
These blocks are for PC642
VoltageSelection if applicable. See
PC 642 Datasheet for additional
information. 0 3 6 is standard for
4-20 mA Signal Line.
70415-Catalog.qxd
6/4/09
12:40 PM
Page 15
Transient Voltage Surge Suppression
Data/Signal Line Protection
IslaGuard® — Ordering Information
®
IslaGuard High Exposure Model Number : I H
1 2 3 6
®
IslaGuard Medium Exposure Model Number : I M 1 2 4
IslaGuard® Low Exposure Model Number : I L 1 2 5
Edco SS64 & SS65 Series
How to Specify the Appropriate Model
All model numbers begin with a prefix (IH, IM, IL).
Moving from left to right, choose correct configuration
from each column for your application. Your completed
model number should look similar to the example below:
Wastewater/Industrial Applications
Example Part Number: IH 120 L 200 X
over-voltage transients with gas tube and silicon avalanche technology. In
The Edco SS64 and Edco SS65 Series suppressors are designed for the water
and wastewater industry. These multi-stage hybrid suppressors address
addition, sneak and fault currents are mitigated with PTC devices which
1
Voltage Code
Nominal Voltage Level
2
Phase Configuration
Model
Identification
L–N
L–L
L–G
120
N/A
120
120
208
120
120
240
120
N/A
240
240
240
277
480
277
277
N/A
480
480
480
120
Phase Configuration
Single Phase 2 Wires + Gnd
(Line & Neutral)
N
Single Phase 2 Wires + Gnd
(Line & Line)
L
Single (Split) Phase
3 Wires + Gnd
Surge Capacity Per Phase
(L-N + L-G)
steel pipe nipples making them suitable for use in severe environments. The
Model
Identification
Edco SS64 models protect a signal pair and the Edco SS65 models protect a
400 kA
L–N
200
signal pair plus the cable shield (drain wire).
L–G
N–G
200
200
400
Model
Identification
S
Three Phase Wye
4 Wires + Gnd
Y
Three Phase Delta
3 Wires + Gnd
D
Three Phase Delta Hi-Leg
4 Wires + Gnd
H
Three Phase Wye w/no Neutral
3 Wires + Gnd
X
4
Surge Capacity (Medium Exposure)
160 kA
Model
Identification
consist of solid-state resettable fuses. The units are encapsulated in stainless
200 kA
Other voltages available, please consult factory.
Surge Capacity Per Phase
(L-N + L-G)
3
Surge Capacity (High Exposure)
L–N
L–G
N–G
200
N/A
200
Features
200 kA
L–N
L–G
N–G
100
100
100
Surge Capacity Per Phase
(L-N + L-G)
100 kA
80
L–G
80
N–G
L–N
80
100 kA
50
100-2
L–G
50
L–G
N–G
Model
Identification
100
N–G
50
50 kA
L–N
L–G
L–G
N–G
100
N/A
100
100-2
N/A
100
25
25
■ Protection for one pair
(Two wires & shield on SS65)
■ Differential and common mode protection
■ Automatic recovery
6
Options
Option
Model
Identification
Rotary Disconnect
R
Surge Counter
C
General Technical Specifications
NEMA 3R Enclosure
50
N–G
Typical Applications
< 1 Nanosecond
Maximum Signal Voltage
28 V Max
DC Clamping Level (L-G)
36 V ±l0%
3R
NEMA 4 Enclosure
4
NEMA 4X Enclosure
4X
72 V ±l0%
Peak Surge Current
100
■ Sneak/fault current protection
■ 5 year warranty
L–N
DC Clamping Level (L-L)
L–N
■ Encapsulated in stainless steel
pipe nipples
■ Resettable fusing—PTCs
Response Time
L–N
■ Transient protection for
low-voltage signal lines
200
100 kA
5
Surge Capacity (Low Exposure)
160
200-2
10 kA (8x20 µs)
25
Maximum let-thru Voltage:
200 kA
25-2
Line-to-Ground (10x700 µs)
L–N
L–G
N–G
25
N/A
25
44 V @ 400 A
Maximum let-thru Voltage:
Line-to-Line (10x700 µs)
90 V @ 400 A
Series Resistance (per conductor)
5 V (typical)
Capacitance:
(Zero Volts Bias)
Recommended Connections
(L-L) 600 pf typical
(L-G) 1200 pf typical
Number of Occurrences
400 @ 500 Amps (10x1000 µs)
Caution: The hybrid design of this product includes series resistance. Do not place this product
in service on any signal lines capable of supplying more than 150 milliamperes continuously.
6
23
Data/Signal Line Protection
Edco CX Series
CCTV & Data Applications/Coax
The Edco CX06-M & Edco CX06-MI Surge Protective Devices (SPDs) implement
three-stage hybrid technology. The SPDs address over-voltage transients with a
primary Gas Discharge Tube (GDT), and secondary Silicon Avalanche Diode
(SAD) components. Over-current protection, e.g. sneak and fault currents, are
mitigated with solid-state resettable fuses — PTCs. The Edco CX06-M & Edco
CX06-MI SPDs are designed in accordance with NFPA 780 (2004 edition)
requirements, with up to 20 kA of surge current capability. The Edco CX06-MI
model has an isolated ground and is recommended for use at the camera end.
Features
Sneak/fault current protection
CX06-MI has an isolated ground
Low insertion loss
5 year warranty
Shielded case
General Technical Specifications
Ordering Information
Operating Voltage
5 VDC
Connection Type
Clamping Voltage
6 VDC
Operating Temperature
0.15 A
Dimensions (Inches)
Operating Current
Peak Surge Current
Frequency Range
Insertion Loss
SPD Technology
20 kA (8 x 20 µs)
0 to 20MHz
< 0.1 dB at 20 MHz
Weight
BNC, 50/75 Ohm
-40°C to +85°C
Head End
CX06-M
Camera End
CX06-MI
M = 1.5H x 1W x 3.25L
MI = 1.5H x 1W x 4L
M = 2.3 oz MI = 3 oz
Certifications
UL 497B
GDT, SAD, w/Series PTC
Edco RM-CX06-16R
Channel Rackmount
The Edco RM-CX06-16R Surge Protective Device (SPD) is a 16 channel coax
SPD implementing three-stage hybrid technology. The SPD addresses overvoltage transients with a primary Gas Discharge Tube (GDT), and secondary
Silicon Avalanche Diode (SAD) components. Over-current protection, e.g.,
sneak and fault currents, are mitigated with new solid-state resettable fuses —
PTCs. The Edco RM-CX06-16R SPD is designed in accordance with NFPA 780
(2004 edition) requirements, with up to 20 kA of surge current capability.
Features
Sneak/fault current protection
16 channel
Low insertion loss
1 year warranty
Shielded case
General Technical Specifications
Operating Voltage
5 VDC
Frequency Range
Clamping Voltage
6 VDC
Insertion Loss
Operating Current
0.15 A
SPD Technology
Peak Surge Current
24
20 kA (8 x 20 µs)
Connection Type
0 to 100 MHz
< 0.1 dB at 20 MHz
GDT, SAD, w/Series PTC
BNC, 50/75 Ohm
Operating Temperature
Dimensions (Inches)
Weight
Certifications
-40°C to +85°C
1.75H x 19W x 2.0D (1U)
3.2 lbs
UL 497B
Technical Bulletins
Technical Bulletins — High-Density Multiple Input Rack
25
Technical Bulletins
Technical Bulletins — Surge Protection for the Water Industry
26
Technical Bulletins
Technical Bulletins — Surge Protection for Power and Signal Lines
27
Headquarters
Surge Protection
30 Charles Street
Binghamton, NY 13901
T: 607-721-8840
T: 800-288-6169
F: 607-722-8713
E: contactsurge@emerson.com
Emerson Network Power.
The global leader in enabling Business-Critical ContinuityTM.
EmersonNetworkPower. com
AC Power
Embedded Computing
Outside Plant
Racks & Integrated Cabinets
Connectivity
DC Power
Embedded Power
Monitoring
Power Switching & Controls
Precision Cooling
Services
Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co.
©2008 Emerson Electric Co.
While every precaution has been taken to ensure accuracy and completeness in this literature, Emerson Network Power assumes no responsibility, and disclaims all liability
for damages resulting from use of this information or for any errors or omissions.
SL-30900 Rev.1 6/08 Printed in USA