Optima Plus® EAF-750

advertisement
Repair Parts and Maintenance Guide
Optima Plus® EAF-750
PARTS LIST—EAF-750 FAUCETS
Item
No.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
EAF-750
1
11.
Code No.
—
—
—
0335001
3335099
0335000
3335023
0335007
0335048
3335086
Part No.
––
––
––
EAF-2
EAF-1017-A
EAF-1
EAF-1008
EAF-9
EAF-48
EAF-1014-A
3335087
EAF-1015-A
3335088
EAF-1016-A
3335018
EAF-1003
Description
Spout Assembly
Integral Side Mixer Handle Cap
Integral Side Mixer Kit
Solenoid
Sensor Assembly
Mounting Hardware
13” (330 mm) Flexible Supply Hose
Filter/Strainer
Battery Box
Multi-Lam Spray Head Kit 0.5 gpm (1.9 Lpm) Male
Cache TJ
Spray Head Kit 1.5 gpm (5.7 Lpm) Aerated Male
Cache TJ
Spray Head Kit 1.5 gpm (5.7 Lpm) Laminar Male
Cache TJ
Battery Replacment Kit (CR-P2)
10
2
3
5
4
6
Faucets and
Soap Dispensers
11
7
9
8
The information contained in this document is subject to change without notice.
194
Repair Parts and Maintenance Guide
Optima Plus® EAF-750
Step 1
Step 1
OPERATION
SENSOR RANGE ADJUSTMENT
1
As the user’s hands enter the beam’s effective range, the beam isStep
reflected
back into the sensor receiver and activates the solenoid valve allowing
water to flow from the faucet. Water will flow until the hands of the user are
removed or until the faucet reaches its automatic time out limit setting.
2x +
2x
1x5+ Sec.
1x5 Sec.
Step
3 +
Step
1 2x
1x5 Sec.
Step
Step23
Step 2
Step 3
Step 4
4x
Step 4
Step 2
Faucets and
Soap Dispensers
Step 5
Step 5
1x
FACTORY
2x DEFAULT = 6
1x
2x
FACTORY DEFAULT = 6
1x5 Sec.
DEFAULT = 6
Step FACTORY
4
Step 5
Step 5
Step 5
5 Sec.
Step 3
1x(
1x, 2x,...,5x)
Step 3
1 x ( 5 1x, 2x,...,5x)
Step
Step 3
1x(
1x, 2x,...,5x)
Step 2
Step 2
Step 4
2x
4x
Step 4
Step 3 Step 2
Step
1 x3 (
1x, 2x,...,5x)
4x
Step 2
1x(
1x, 2x,...,5x)
4x
Step 3
1x(
1x, 2x,...,5x)
HOT LIMIT STOP ADJUSTMENT
Step 1
Step 4
Step
4
5 Sec.
Limit the maximum water temperature. Note: this does not take the place
of an ASSE 1070 certified mixing device. But is an added measure to limit
delivery of hot water.
5 Sec.
Step 1
1x
2x +
1x5 Sec.
2x +
1x5 Sec.
2x +
5 Sec.
5 Sec.
Step 1
1x
2x
FACTORY DEFAULT
=6
1x
2x
FACTORY DEFAULT
=
8x6
7x
FACTORY DEFAULT = 6
8x
Step 4
7x
8x
Step 4
7x
4x
5 Step
Sec.2
1x
2x
Step 2 Step 1
Step 2
4x
Step 1
Step 2
8x
7x
Factory setting is appropriate for the
majority of applications and should
not require resetting unless under
extreme situations.
SET AND FIX TEMPERATURE (OPTIONAL)
Step
21
Step
8x
8x 7x
7x
Step 4
Step 4
Step 5
Step 5
Step 5
Step 5
12/24 LINE PURGE FEATURE
This feature will operate the faucet
every 12 or 24 hours since last
Step 5 use, if not used to prevent stagnant
water conditions.
Default purge duration is two (2)
minutes.
Consult factory regarding other
timing options.
1x 24 sec
2x
Step 3
Step 3
Step 3
195
The information contained in this document is subject to change without notice.
Repair Parts and Maintenance Guide
Optima Plus® EAF-750
I.Q.-CLICK FEATURE
BATTERY REPLACEMENT
1. CONTINUOUS RUN
Continuous run of water for
two minutes.
Note: Replace battery when red LED
1x
indicator flashes each time faucet
is in use or when faucet stops
functioning.
No need to turn off water.
Loosen screw with hex wrench
1 and
x
remove cap. Slide cover
forward and lift off.
1 x 2 Sec.
1 x 2 Sec.
Faucet will operate
1 x 2normally
Sec.after
two minutes or after pressing
i.q.-click button once.
1x
Remove battery.
1x
Replace batteries with new “CR-P2”
lithium battery
(Sloan Kit# EAF-1003A).
2x
2x
2. CLEANING MODE
Pause faucet for cleaning
2 x for
two (2) minutes.
1x
1x
Replace cover.
1x
Faucet will operate
1 x 2normally
Sec.after
two (2) minutes or after pressing
i.q.-click button once.
1x
1 x 6 Sec.
1x
OFF-DELAY (FOLLOW UP TIME)
1x
Sec.
1x
1x
1 x 6 Sec.
1x
1x
1x
Sec.
1x
Faucet will operate for
four (4) seconds.
1x
1 x 6 Sensor
Sec. will flash once and then the
1x
Sec.
1 xfaucet is ready to operate.
1x
1x
Wait 10 seconds and then the
faucet is ready for operation.
1x
The information contained in this document is subject to change without notice.
196
Faucets and
Soap Dispensers
Duration of time the water runs after
target is removed. 2 x
Press the button for approximately
six (6) seconds. Release.
Press again (water flows) and
release when the desired time
of water flow (0-5 seconds) is
reached.
1x by pressing i.q. cliq
Activate faucet
one (1) time, then immediately step
away.
Repair Parts and Maintenance Guide
Optima Plus® EAF-750
TROUBLESHOOTING GUIDE
CARE AND CLEANING
1. Faucet DOES NOT function.
A. Adhesive packaging label affixed over sensor eye. Remove adhesive
label from sensor eye.
B. “Intermittent Off” is activated. Press button once.
C. Water supply stop(s) closed. Open water supply stop(s).
D. Battery is “dead”. Replace battery (refer to Battery Replacement
section of guide).
DO NOT USE abrasive or chemical cleaners
(including chlorine bleach) to clean faucets that may
dull the luster and attack the chrome or special
decorative finishes. Use ONLY mild soap and water,
then wipe dry with clean cloth or towel. While
cleaning the bathroom sink, protect the faucet from
any splattering of cleaner. Acids and cleaning fluids
will discolor or remove chrome plating.
2. Faucet delivers water in an uncontrolled manner.
A. Reflection. Remove reflective surface.
B. Faucet is not working properly. Contact Sloan Technical Support.
When assistance is required, please contact
Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614).
3. Faucet DOES NOT deliver any water when Sensor is activated.
INDICATOR: Solenoid Valve produces an audible “CLICK.”
A. Water supply stop(s) closed. Open water supply stop(s).
B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall
water supply stop strainer(s). Replace strainer(s), if required.
INDICATOR: Solenoid Valve DOES NOT produce an audible
“CLICK.”
A. Battery low (battery powered models). Replace battery (refer to Battery
Replacement section of guide).
Faucets and
Soap Dispensers
4. Faucet delivers only a slow flow or dribble when sensor is
activated.
A. Water supply stop(s) are partially closed. Completely open water
supply stop(s).
B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall
water supply stop strainer(s). Replace strainer(s), if required.
C. Spray head is clogged. Remove, clean, and reinstall spray head.
Replace spray head, if required.
D. Faucet is not working properly. Contact Sloan Technical Support.
5. Faucet DOES NOT stop delivering water or contrinues to drip after
user is no longer detected.
A. Faucet is not working properly. Contact Sloan Technical Support.
6. LED indicator blinks when faucet is in use.
A. Battery low (battery powered models). Replace battery (refer to Battery
Replacement section of guide).
7. The water temperature is too hot or too cold on a faucet
connected to hot and cold supply lines.
A. Supply stops are not adjusted properly. Adjust supply stops.
197
The information contained in this document is subject to change without notice.