Repair Parts and Maintenance Guide Optima Plus® EAF-750 PARTS LIST—EAF-750 FAUCETS Item No. 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. EAF-750 1 11. Code No. — — — 0335001 3335099 0335000 3335023 0335007 0335048 3335086 Part No. –– –– –– EAF-2 EAF-1017-A EAF-1 EAF-1008 EAF-9 EAF-48 EAF-1014-A 3335087 EAF-1015-A 3335088 EAF-1016-A 3335018 EAF-1003 Description Spout Assembly Integral Side Mixer Handle Cap Integral Side Mixer Kit Solenoid Sensor Assembly Mounting Hardware 13” (330 mm) Flexible Supply Hose Filter/Strainer Battery Box Multi-Lam Spray Head Kit 0.5 gpm (1.9 Lpm) Male Cache TJ Spray Head Kit 1.5 gpm (5.7 Lpm) Aerated Male Cache TJ Spray Head Kit 1.5 gpm (5.7 Lpm) Laminar Male Cache TJ Battery Replacment Kit (CR-P2) 10 2 3 5 4 6 Faucets and Soap Dispensers 11 7 9 8 The information contained in this document is subject to change without notice. 194 Repair Parts and Maintenance Guide Optima Plus® EAF-750 Step 1 Step 1 OPERATION SENSOR RANGE ADJUSTMENT 1 As the user’s hands enter the beam’s effective range, the beam isStep reflected back into the sensor receiver and activates the solenoid valve allowing water to flow from the faucet. Water will flow until the hands of the user are removed or until the faucet reaches its automatic time out limit setting. 2x + 2x 1x5+ Sec. 1x5 Sec. Step 3 + Step 1 2x 1x5 Sec. Step Step23 Step 2 Step 3 Step 4 4x Step 4 Step 2 Faucets and Soap Dispensers Step 5 Step 5 1x FACTORY 2x DEFAULT = 6 1x 2x FACTORY DEFAULT = 6 1x5 Sec. DEFAULT = 6 Step FACTORY 4 Step 5 Step 5 Step 5 5 Sec. Step 3 1x( 1x, 2x,...,5x) Step 3 1 x ( 5 1x, 2x,...,5x) Step Step 3 1x( 1x, 2x,...,5x) Step 2 Step 2 Step 4 2x 4x Step 4 Step 3 Step 2 Step 1 x3 ( 1x, 2x,...,5x) 4x Step 2 1x( 1x, 2x,...,5x) 4x Step 3 1x( 1x, 2x,...,5x) HOT LIMIT STOP ADJUSTMENT Step 1 Step 4 Step 4 5 Sec. Limit the maximum water temperature. Note: this does not take the place of an ASSE 1070 certified mixing device. But is an added measure to limit delivery of hot water. 5 Sec. Step 1 1x 2x + 1x5 Sec. 2x + 1x5 Sec. 2x + 5 Sec. 5 Sec. Step 1 1x 2x FACTORY DEFAULT =6 1x 2x FACTORY DEFAULT = 8x6 7x FACTORY DEFAULT = 6 8x Step 4 7x 8x Step 4 7x 4x 5 Step Sec.2 1x 2x Step 2 Step 1 Step 2 4x Step 1 Step 2 8x 7x Factory setting is appropriate for the majority of applications and should not require resetting unless under extreme situations. SET AND FIX TEMPERATURE (OPTIONAL) Step 21 Step 8x 8x 7x 7x Step 4 Step 4 Step 5 Step 5 Step 5 Step 5 12/24 LINE PURGE FEATURE This feature will operate the faucet every 12 or 24 hours since last Step 5 use, if not used to prevent stagnant water conditions. Default purge duration is two (2) minutes. Consult factory regarding other timing options. 1x 24 sec 2x Step 3 Step 3 Step 3 195 The information contained in this document is subject to change without notice. Repair Parts and Maintenance Guide Optima Plus® EAF-750 I.Q.-CLICK FEATURE BATTERY REPLACEMENT 1. CONTINUOUS RUN Continuous run of water for two minutes. Note: Replace battery when red LED 1x indicator flashes each time faucet is in use or when faucet stops functioning. No need to turn off water. Loosen screw with hex wrench 1 and x remove cap. Slide cover forward and lift off. 1 x 2 Sec. 1 x 2 Sec. Faucet will operate 1 x 2normally Sec.after two minutes or after pressing i.q.-click button once. 1x Remove battery. 1x Replace batteries with new “CR-P2” lithium battery (Sloan Kit# EAF-1003A). 2x 2x 2. CLEANING MODE Pause faucet for cleaning 2 x for two (2) minutes. 1x 1x Replace cover. 1x Faucet will operate 1 x 2normally Sec.after two (2) minutes or after pressing i.q.-click button once. 1x 1 x 6 Sec. 1x OFF-DELAY (FOLLOW UP TIME) 1x Sec. 1x 1x 1 x 6 Sec. 1x 1x 1x Sec. 1x Faucet will operate for four (4) seconds. 1x 1 x 6 Sensor Sec. will flash once and then the 1x Sec. 1 xfaucet is ready to operate. 1x 1x Wait 10 seconds and then the faucet is ready for operation. 1x The information contained in this document is subject to change without notice. 196 Faucets and Soap Dispensers Duration of time the water runs after target is removed. 2 x Press the button for approximately six (6) seconds. Release. Press again (water flows) and release when the desired time of water flow (0-5 seconds) is reached. 1x by pressing i.q. cliq Activate faucet one (1) time, then immediately step away. Repair Parts and Maintenance Guide Optima Plus® EAF-750 TROUBLESHOOTING GUIDE CARE AND CLEANING 1. Faucet DOES NOT function. A. Adhesive packaging label affixed over sensor eye. Remove adhesive label from sensor eye. B. “Intermittent Off” is activated. Press button once. C. Water supply stop(s) closed. Open water supply stop(s). D. Battery is “dead”. Replace battery (refer to Battery Replacement section of guide). DO NOT USE abrasive or chemical cleaners (including chlorine bleach) to clean faucets that may dull the luster and attack the chrome or special decorative finishes. Use ONLY mild soap and water, then wipe dry with clean cloth or towel. While cleaning the bathroom sink, protect the faucet from any splattering of cleaner. Acids and cleaning fluids will discolor or remove chrome plating. 2. Faucet delivers water in an uncontrolled manner. A. Reflection. Remove reflective surface. B. Faucet is not working properly. Contact Sloan Technical Support. When assistance is required, please contact Sloan Technical Support at: 1-888-SLOAN-14 (1-888-756-2614). 3. Faucet DOES NOT deliver any water when Sensor is activated. INDICATOR: Solenoid Valve produces an audible “CLICK.” A. Water supply stop(s) closed. Open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s), if required. INDICATOR: Solenoid Valve DOES NOT produce an audible “CLICK.” A. Battery low (battery powered models). Replace battery (refer to Battery Replacement section of guide). Faucets and Soap Dispensers 4. Faucet delivers only a slow flow or dribble when sensor is activated. A. Water supply stop(s) are partially closed. Completely open water supply stop(s). B. Water supply stop strainer(s) clogged. Remove, clean, and reinstall water supply stop strainer(s). Replace strainer(s), if required. C. Spray head is clogged. Remove, clean, and reinstall spray head. Replace spray head, if required. D. Faucet is not working properly. Contact Sloan Technical Support. 5. Faucet DOES NOT stop delivering water or contrinues to drip after user is no longer detected. A. Faucet is not working properly. Contact Sloan Technical Support. 6. LED indicator blinks when faucet is in use. A. Battery low (battery powered models). Replace battery (refer to Battery Replacement section of guide). 7. The water temperature is too hot or too cold on a faucet connected to hot and cold supply lines. A. Supply stops are not adjusted properly. Adjust supply stops. 197 The information contained in this document is subject to change without notice.