LOW PRESSURE FILTERS NF MMP Series Manifold Modular Parallel Inline Filters - with ECOmicron®-fit option 360 psi • up to 450 gpm (4” header) • up to 1350 gpm (6” header) Hydraulic Symbol NF 52XX Manifold Modular NF 52XX MANIFOLD A → A → MODULAR NF 52XX MANIFOLD MODULAR B ← B ← NF 104XX Manifold Modular A → A → NF 104XX MANIFOLD MODULAR NF 104XX MANIFOLD MODULAR B ← B ← Features Technical Specifications • L ess weight/handling - reducing shipping costs • Towers isolated individually • • • • • (versus NFD 5210 and up, duty-standby arrangement) Lower Clean ∆P (less filters, elements, and piping) Significant Cost Reduction (less components, smaller footprint) Ease of Operation/Maintenance (less leakage points) Uses NF Series proven housing and element technology Replacement Elements - Optimicron®, ECOmicron®-fit, ECOmicron® (environmentally friendly, incinerable) Configurations NF Optimicron® Size 5210, 7810, 10410 • Bypass located in element endcap NF ECOmicron®-fit Size 5214, 7814, 10414 • Bypass separate, replaceable component Applications Pulp & Paper Steel / Heavy Industry Industrial Mounting Method Port Connection See drawings 4” SAE-64 Flange Code 61 (with M16 bolts included) Flow Direction 2.0 version Construction Materials Head, Housing, Lid 6” Piping headers Elbows, Manifolds Flow Capacity 5210, 5214, 7810, 7814, 10410, 10414 Inlet: Side Outlet: Side Aluminum Carbon Steel Ductile Iron DCP… 4” Header Piping 450 gpm (1700 lpm) DC7… 6” Header Piping 5210, 5214 900 gpm (3406 lpm) 7810, 7810, 10410, 10414 1350 gpm (5110 lpm) Housing Pressure Rating Max. Allowable Working Pressure 360 psi (25 bar) Fatigue Pressure 360 psi (25 bar) Burst Pressure Contact HYDAC Element Collapse Pressure Rating ON, 290 psid (20 bar) ECON2, ECO/N 145 psid (10 bar) Fluid Temperature Range 14°F to 212°F (-10°C to 100°C) Consult HYDAC for applications below 14˚F (-10˚C) Fluid Compatibility Compatible with all hydrocarbon based, synthetic, water glycol, oil/water emulsion, and high water based fluids when the appropriate seals are selected. Indicator Trip Pressure ∆P = 29 psid (2 bar) -10% ∆P = 72 psid (5 bar) -10% 2.0 - Differential Bypass Valve Cracking Pressure ∆P = 14.5 psid (1 bar) +10% ∆P = 43 psid (3 bar) +10% (standard) ∆P = 87 psid (6 bar) +10% D180 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Model Code NF ECO/N 5214 D C P 6 D 2.0 / A V B6 EM - DBV Filter Type NF = Inline Filter Element Media ON = Optimicron® ECO/N = ECOmicron®-fit ECON2 = ECOmicron® Size 5210, 7810, 10410 = ON, ECON2 5214, 7814, 10414 = ECO/N Operating Pressure D = 360 psi (25 bar) Type of Isolation Valve C = Butterfly valves upstream and downstream Type of Connection P = SAE DN 100 (4”) Flange - Code 61 7 = 6” ANSI CS 300lb. Flange Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 6, 12, 25 = ECO/N 3, 5, 10, 20 = ECON2 Type of ∆P Clogging Indicator A = No Indicator (plugged) B, BM, C, D, LE (Others available upon request) Type Number / Modification Number 2.0= Inline Filter - ∆P indicator Flow Path (facing Inlet manifold headers) A = Left inlet, Left outlet C = Left inlet, Right outlet B = Right inlet, Right outlet D = Right inlet, Left outlet Seals (omit) = Nitrile rubber (NBR) (standard) Bypass Valve (omit) = B1 = B6 = KB = V = Fluorocarbon elastomer (FKM) 43 psid (3 bar) (standard) 14.5 psid (1 bar) (lube or coolant) 87 psid (6 bar) (return line extended life) no bypass (flushing system) EPR = Ethylene propylene rubber (EPR) not available with ECON2 Supplementary Details SO263 = Modification of ON and W/HC elements for Skydrol or HYJET phosphate ester fluids L24, L48, L110, L220 = Lamp for D-type clogging indicator (LXX, XX = voltage) SFREE = Element specially designed to minimize electrostatic charge generation EM DBV = = Manual vent valve set Double butterfly valve VKD = cRUus= Drain manifold Electrical Indicator with underwriter’s recognition Replacement Element Model Code (ON, ECON2) 2600 R 005 ON / V B6 Clogging Indicator Model Code . Size 2600 Filtration Rating (micron) 1, 3, 5, 10, 15, 20 = ON 3, 5, 10, 20 = ECON2 Element Media ON, ECON2 Seals (omit)=Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPDM) Bypass Valve (omit) = 43 psid (3 bar) (standard) B6 = 87 psid (6 bar) Supplementary Details SO263 = (See above) B1 = 14.5 psid (1 bar) KB = no bypass SFREE = (See above) Replacement Element Model Code (ECO/N) 1.14.39D 6 ECO/N - V. Size 1.14.39D Filtration Rating (micron) 3, 6, 12, 25 = ECO/N Element Media ECO/N VM 5 BM . X / . Indicator Prefix VM = ∆P, G 1/2” 3000 psi VD =∆P G 1/2” 6000 psi (2.0 ver. - LE Indicators only) Trip Pressure 2 = 29 psid (2 bar) (return filters) 5 = 72 psid (5 bar) (optional) Type of Indicator A = No indicator, plugged port BM = Pop-up indicator (manual reset) C = Electric switch - SPDT D = Electric switch and LED light - SPDT LE = Electric switch and pop-up Modification Number Supplementary Details Seals (omit) = Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) EPR = Ethylene Propylene rubber (EPDM) Light Voltage (D type indicators only) L24 = 24V L110 = 110V Thermal Lockout (VM type C, D, J, J4 only) T100 = Lockout below 100˚F Underwriter’s Approval (VM type C, D, J, J4 only) cRUus= Electrical Indicator with underwriter’s recognition (For additional details and options, see Section G - Clogging Indicators.) Seals (omit)=Nitrile rubber (NBR) (standard) V = Fluorocarbon elastomer (FKM) Model Codes Containing RED are non-stock items — Minimum quantities may apply – Contact HYDAC for information and availability PN#02081318 / 03.16 / FIL1505-1696 D181 LOW PRESSURE FILTERS Dimensions NF 5210 2.0 Version (Modular Parallel) 11.81 300 23.32 592.3 [36.02] 915 Clearance required for element removal 10.24 260 Lid Top 28.18 716 Manual vent valves Option G 1/2" ports 2 places 52.68 1338 Connection for static clogging indicator G 1/2" 2 places 7.87 200 3.06 77.8 0.75 19 Thru 8 places 60.08 1526 INLET SAE DN100 4" Flange Filling connection port G 3/4" 2 places 15.96 405.5 3.94 100 Isolation valve INLET Drain manifold (Option) 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 Isolation valve OUTLET OUTLET SAE DN100 4" Flange 25.66 652 ∆ P Clogging indicator port G 1/2" 2 places Dirty side drain port G 1/2" 11.81 300 0.55 14 Thru 4 Places Size 5210 Weight (lbs.) 287 4.72 120 Mounting pattern Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. D182 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Dimensions: NF 5214 2.0 Version (Modular Parallel) 11.81 300 23.32 592.3 28.18 716 [36.02] 915 Clearance required for element removal 10.24 260 Lid top Manual vent valves Option G 1/2" ports 2 places 68.11 1730 7.87 200 3.06 77.8 0.75 19 Thru 8 places Connection for static clogging indicator G 1/2" 2 places Isolation valve INLET 60.78 1543.8 INLET SAE DN100 4" Flange Filling connection port G 3/4" 2 places Drain manifold (Option) 15.96 405.5 3.94 100 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 Isolation valve OUTLET OUTLET SAE DN100 4" Flange 25.66 652 ∆ P Clogging indicator port G 1/2" 2 places 11.81 300 0.55 14 Thru 4 Places Size 5214 Weight (lbs.) 291 Dirty Side Drain Port G 1/2" 4.72 120 Mounting pattern Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. PN#02081318 / 03.16 / FIL1505-1696 D183 LOW PRESSURE FILTERS Dimensions: NF 7810 2.0 Version (Modular Parallel) 11.81 300 11.81 300 23.32 592.3 10.24 260 Lid Top Manual vent valves Option (G 1/2" ports) (3 places) 60.08 1526 3.06 77.8 Connection for static clogging indicator G 1/2" 3 places 0.75 19 Thru 8 places Filling connection port G 3/4" 3 places Isolation valve INLET 52.69 1338.3 15.96 405.5 3.94 100 42.67 1084 [36.02] 915 Clearance required for element removal 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 7.87 200 INLET SAE DN100 4" Flange Drain manifold (Option) Isolation valve OUTLET OUTLET SAE DN100 4" Flange ∆ P Clogging indicator port G 1/2" 3 places 34.24 869.7 Dirty Side Drain Port G 1/2" 11.81 300 0.55 14 thru 6 places Size 7810 Weight (lbs.) 370 13.7 348 4.72 120 Mounting pattern Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. D184 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Dimensions: NF 7814 2.0 Version (Modular Parallel) 11.81 300 11.81 300 23.32 592.3 10.24 260 Lid Top Manual vent valves Option (G 1/2" ports) (3 places) 60.08 1526 3.06 77.8 Connection for static clogging indicator G 1/2" 3 places 0.75 19 Thru 8 places Filling connection port G 3/4" 3 places Isolation valve INLET 52.69 1338.3 15.96 405.5 3.94 100 42.67 1084 [36.02] 915 Clearance required for element removal 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 7.87 200 INLET SAE DN100 4" Flange Drain manifold (Option) Isolation valve OUTLET OUTLET SAE DN100 4" Flange ∆ P Clogging indicator port G 1/2" 3 places 34.24 869.7 Dirty Side Drain Port G 1/2" 11.81 300 0.55 14 thru 6 places Size 7814 Weight (lbs.) 380 13.7 348 Mounting pattern 4.72 120 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. PN#02081318 / 03.16 / FIL1505-1696 D185 LOW PRESSURE FILTERS Dimensions: NF 10410 2.0 Version (Modular Parallel) 11.81 300 11.81 300 11.81 300 23.32 592.3 51.22 1301 [36.02] 915 Clearance required for element removal 10.24 260 Lid top 60.08 1526 3.06 77.8 Connection for static clogging indicator G 1/2" 4 places 7.87 200 52.69 0.75 1338.3 19 Thru 8 places Filling connection port G 3/4" 4 places 15.96 405.5 3.94 100 Manual vent valves Option (G 1/2" ports) (4 places) 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 Isolation valve INLET INLET SAE DN100 4" Flange Drain manifold (Option) Isolation valve OUTLET OUTLET SAE DN100 4" Flange Dirty Side Drain Port G1/2" 49.28 1251.8 ∆ P Clogging indicator port G 1/2" 4 places 11.81 300 11.81 300 0.55 14 Thru 8 Places Size Weight (lbs.) 11.81 300 Mounting pattern 4.72 120 10410 554 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. D186 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Dimensions: NF 10414 2.0 Version (Modular Parallel) 11.81 300 11.81 300 11.81 300 23.32 592.3 51.22 1301 [36.02] 915 Clearance required for element removal 10.24 260 Lid top 3.06 77.8 Connection for static clogging indicator G 1/2" 4 places 68.11 1730 7.87 200 0.75 19 Thru 8 places Filling connection port G 3/4" 4 places 60.78 1543.8 15.96 405.5 3.94 100 Manual vent valves Option G 1/2" ports 4 places 5.12 130 Bolt Spacing 13.21 335.5 17.81 452.3 Isolation valve INLET INLET SAE DN100 4" Flange Drain manifold (Option) Isolation valve OUTLET OUTLET SAE DN100 4" Flange 49.28 1251.8 ∆ P Clogging indicator port G 1/2" 4 places Dirty Side Drain Port G 1/2" 11.81 300 11.81 300 0.55 14 Thru 8 Places Size Weight (lbs.) 11.81 300 Mounting pattern 4.72 120 10414 562 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. PN#02081318 / 03.16 / FIL1505-1696 D187 LOW PRESSURE FILTERS Dimensions: NF 5210DC7 2.0 Version (Modular Parallel High Flow) 11.81 300 [36.02] 915 Clearance required for element removal Manual vent valves Option (G 1/2" ports) (2 places) Isolation valve INLET Connection for static clogging indicator G 1/2" 2 places 64.83 1646.7 60.59 1539 INLET 6" ANSI CS 300 lb flange 51.8 1315.7 Drain manifold (Option) Filling connection (G 3/4" ) 2 places 18.94 481 ∆ P Clogging indicator port G 1/2" (2 places) 15.39 391 29.27 743.4 Isolation valve OUTLET 25.84 656.4 OUTLET 6" ANSI CS 300 lb flange 29.98 761.5 M16 X 2 Threaded Typ 1.5 38.1 12.12 307.8 1.5 38.1 1.5 38.1 4 101.6 13.62 345.9 Mounting Pattern Size Weight (lbs.) 5210DC7 530 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. D188 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Dimensions: NF 7810DC7 2.0 Version (Modular Parallel High Flow) 11.81 300 11.81 300 5.9 150 10.24 260 Lid top 58.54 1487 64.79 1645.7 7.87 200 Connection for static clogging indicator G 1/2" 3 places [36.02] 915 Clearance required for element removal Manual vent valves Option G 1/2" ports 3 places Isolation valve INLET INLET 6" ANSI CS 300 lb flange 51.8 1315.7 Drain manifold Option Filling connection G 3/4" 3 places 18.94 481 OUTLET 6" ANSI CS 300 lb flange Isolation valve OUTLET Dirty Side Drain Port G 1/2" 3 Places 16.18 411 ∆ P Clogging indicator port G 1/2" (3 Places) 6.25 158.8 39.76 1009.8 30.05 763.4 ∆ P Clogging indicator port G 1/2" (3 places) M16 X 2 Threaded Typ 1.5 38.1 11.81 300 11.81 300 25.12 638.1 1.5 38.1 4 101.6 Mounting Pattern Size Weight (lbs.) 7810DC7 679 Dimensions shown are [inches] millimeters for general information and overall envelope size only. Weights listed include element. For complete dimensions please contact HYDAC to request a certified print. PN#02081318 / 03.16 / FIL1505-1696 D189 LOW PRESSURE FILTERS Sizing Information Total pressure loss through the filter is as follows: Assembly ∆P = Housing ∆P + Element ∆P Housing Curve: Pressure loss through housing is as follows: Actual Specific Gravity Housing ∆P = Housing Curve ∆P x 0.86 Adjustments must be made for viscosity & specific gravity of the fluid to be used! (see “Sizing HYDAC Filter Assemblies” in Section B - Overview) NF 330/500/750 HOUSING Q in l/min 0 100 200 300 400 500 0.8 10 0.6 8 6 0.4 4 0.2 2 0 4.0 0 0 20 40 60 80 100 120 140 Q in gpm NF 1310-2650 HOUSING Q in l/min 0 400 800 1200 1600 2000 0.3 3.0 0.2 2.0 0.1 1.0 1.0 2.5 0 100 200 300 400 Q in gpm 500 0.16 0.12 1.5 0.08 1.0 0.04 0.5 0 100 200 300 400 Q in gpm 500 0 0 0.05 0 100 200 300 400 Q in gpm 500 2.0 0.12 1.6 1.2 0.08 0.8 0.04 0.4 0 0 100 200 300 400 Q in gpm NF 7810DC7 HOUSING Q in l/min 0 0 1000 2000 3000 4000 5000 6000 500 20.0 0.9 10.0 1.2 15.0 0.9 10.0 0.6 5.0 0 1000 2000 3000 4000 5000 6000 1.8 1.5 0 NF 10410 HOUSING Q in l/min 0 400 800 1200 1600 2000 NF 5210DC7 HOUSING Q in l/min 25.0 0 0 NF 7810 HOUSING Q in l/min 0 400 800 1200 1600 2000 2.0 0 0.15 0.1 2.0 0 NF 5210 HOUSING Q in l/min 0 400 800 1200 1600 2000 3.0 0.2 0.6 5.0 0.3 0.3 0 250 500 750 1000 1250 1500 Q in gpm 0 0 0 250 500 750 1000 1250 1500 0 Q in gpm All Element K Factors in psi / gpm. D190 PN#02081318 / 03.16 / FIL1505-1696 LOW PRESSURE FILTERS Element K Factors (K) Flow Factor x Flow Rate (gpm) x ∆P Elements = Elements (From Tables Below) Optimicron Size 1300 R XXX ON 2600 R XXX ON Actual Viscosity (SUS) x Actual Specific Gravity 141 SUS 0.86 …R…ON 1 µm 0.094 0.046 3 µm 0.04 0.02 5 µm 0.032 0.016 ECOmicron Size 1300 R XXX ECON2 2600 R XXX ECON2 3 μm 0.044 0.022 5 μm 0.033 0.016 ECOmicron fit Size 1.14.16DXXECO/N 1.14.39DXXECO/N 3 μm 0.046 0.017 6 μm 0.041 0.016 10 µm 0.019 0.01 15 µm 0.018 0.009 20 µm 0.012 0.006 ...R...ECON2 10 μm 0.022 0.011 20 μm 0.016 0.005 12 μm 0.022 0.008 25 μm 0.015 0.006 1.14.XXDXXECO/N Notes PN#02081318 / 03.16 / FIL1505-1696 D191