This Data Sheet Contains Important Information About The Product. VersaFlashTM Solid Sample Cartridge Kits Cat. Nos. 97721-U, 97722-U, 97738-U, 97746-U, 97747-U, 97751-U - 97756-U c) Once the desired volume of adsorbed media is in the solid sample cartridge, backfill with non-adsorbed packing media to within 0.5 cm from the top of the cartridge. Attach frit insertion sleeve and use frit insertion plunger to level the packing media, do not over pack the media. E000927 The solid sample cartridge kits are designed for samples that have low solubility. Both liquid and solid samples with low solubility can be dissolved in a small amount of strong solvent and absorbed onto an inert media, such as silica or celite. The solvent is evaporated and the absorbed media is packed into the solid sample cartridge. The samples thus can be desorbed onto the separation cartridge in the VersaFlash station. The materials of construction of the solid sample module are polypropylene, stainless steel, and Teflon®. The solid sample cartridges should be used at operating pressures less than 50 psi. The solid sample cartridge kits consist of: 40 mm SSM Kit Cat. No. Small Solid Sample Modules* Large Solid Sample Modules* Stainless Steel Cap Frit Insertion Tools Polyethylene Frits Replacement O-ring 97738-U 6 each 40 x 37.5 mm 6 each 40 x 75 mm 1 with O-ring 40 mm Plunger/sleeve 12 @ 40 mm 1 @ 40 mm P001006 d) Once the packing is leveled, place frit (smooth side up) into the frit insertion sleeve. Use the frit insertion plunger to press the frit into place, this will set the proper depth for the frit. 80 mm SSM Kit 97753-U 3 each 80 x 50 mm 3 each 80 x 100 mm 1 with O-ring 80 mm plunger/sleeve 6 @ 80 mm 1 @ 80 mm *1 endcap pre-assembled Loading a Solid Sample Cartridge If the sample material exhibits low solubility in the mobile phase to be used in the flash purification, it may be necessary to apply the sample through the use of a solid sample module using the following procedure: P001007 a) Adsorb the sample material onto a solid support media such as silica or celite. The media is then dried along with the adsorbed sample material. b) Pour the desired volume of adsorbed media into the appropriate sized solid sample cartridge. P001008 T703009D ©2004 Sigma-Aldrich Co. SUPELCO Bellefonte, PA e) Remove the frit insertion sleeve and inspect the cartridge. Wipe any excess packing from the top edge of the cartridge. P001009 f) Attach the stainless steel cap and hand-tighten. Approximately 4 mm of thread will be visible on the tube; this is normal. The solid sample cartridge is ready to desorb by placing a VersaPak™ cartridge after the solid sample cartridge using the cartridge stacking connector. Follow instructions for cartridge stacking in the VersaFlash station instruction manual. g) The stainless steel cap should be removed and cleaned directly after use. Under prolonged conditions, some organic solvents could swell the cartridge causing difficulty removing the stainless steel cap. If this occurs, flush the solvent from the cartridge and let it soak overnight in a non-aggressive solvent such as water or methanol to reduce the swelling. The stainless steel cap is machined for use with a 13/16" wrench if the cap cannot be removed by hand. Never use a wrench to tighten the cap onto the cartridge. h) It is recommended that you periodically inspect and replace the O-ring inside the stainless steel cap. To remove the worn O-ring, simply use forceps or a small spatula to pry the O-ring from the groove. Care should be taken to not damage the Teflon flow distributor or groove in the cap. To replace the O-ring, lay the new O-ring inside the cap. The O-ring should be pressed into the Oring groove prior to screwing the cartridge on. Use a dull object to press it into place and to minimize the potential for damage to the O-ring. Screw the empty solid sample module into the cap to seat the new O-ring. Additional replacement O-rings are available. (See Ordering Information). i) The solid sample cartridge tubes are intended for one time use, they are not recommended for reuse, due to concerns of sample cross contamination. Ordering Information Description P001010 Cat. No. VersaFlash 40 mm Solid Sample Cartridge Kit VersaFlash 40 mm x 37.5 mm Solid Sample Cartridges, 12/pk. VersaFlash 40 mm x 75 mm Solid Sample Cartridges, 12/pk. VersaFlash 40 mm Solid Sample Module Cap with O-rings VersaFlash 40 mm Solid Sample Module O-ring, 3/pk. 97738-U 97746-U 97747-U 97722-U 97721-U VersaFlash 80 mm Solid Sample Cartridge Kit VersaFlash 80 mm x 50 mm Solid Sample Cartridges, 6/pk. VersaFlash 80 mm x 100 mm Solid Sample Cartridges, 6/pk. VersaFlash 80 mm Solid Sample Module Cap with O-rings VersaFlash 80 mm Solid Sample Module O-ring, 1/pk. VersaFlash 80 mm to 110 mm Cartridge Stacking Connector, 1/pk. 97753-U 97751-U 97752-U 97754-U 97755-U 97756-U Flash Bulk Media VersaFlash spherical silica, dried, 100 g VersaFlash spherical silica, dried, 1 Kg VersaFlash spherical C18 silica, 100 g 97728-U 97729-U 97727-U In the USA and Canada: please contact us at the following telephone numbers Monday - Friday during the hours of 8AM - 8PM Eastern Time: Phone: 800-359-3041 / 814-359-3041 Fax: 800-359-3044 / 814-359-5468 Email: techservice@sial.com Other countries, contact your local Sigma-Aldrich representative. For more information, visit sigma-aldrich.com Trademarks Teflon - E.I. duPont de Nemours & Co., Inc. VersaFlash, VersaPak - Sigma-Aldrich Co.