Electrified Cylindrical Locks With Request-to

advertisement
Z7200 Series Electrified Cylindrical Lockset
Electrified Cylindrical Locks
With Request-to-Exit Output
Application
Z7200 Electrified Cylindrical Locksets are designed for the
access control of openings in commercial, industrial and
institutional facilities where code compliance, dependable
operation and resistance to physical abuse is required,
including:
•
•
•
•
• Government Centers
High-Rise Offices
Hospitals
Universities
Museums
• Airports
• Factories
Building and Fire Life Safety Code Compliant
Z7200 electrified cylindrical locks ensure that the door stays
latched even when unlocked, maintaining fire door integrity.
Z7200 locksets comply with all national building and fire
life safety code requirements for use on fire rated doors,
including high-rise stairwell and elevator lobby doors where
the use of electric strikes and magnetic locks is prohibited.
Security with Superior Aesthetics
Available in failsafe and failsecure modes to accommodate
either security or fire life safety applications, Z7200
electrified locksets provide a superior appearance compared
to exposed and vulnerable electric strikes and magnetic
locks, while eliminating the need for request-to-exit devices.
Vandal Resistant Lever Handles Standard
With SDC Brand Lockset
When locked, the built-in clutch permits the
handles to operate without retracting the latch,
reducing potential for damage.
Features
•
Request-to-exit output standard with all locksets
•
Dual Voltage 12 and 24VDC
•
Choice of failsafe or failsecure operating mode
•
Clutch allows the lever to operate while the door stays locked for increased vandal and abuse resistance
•
Independant power return springs for effective lever action and prevention of lever sag
•
SDC cylinder with 'C' keyway
•
Small format Interchangeable core (optional)
•
No exposed mounting screws
•
Strikes available to match existing frame preparation
•
Choice of seven architectural finishes
•
Exceeds ANSI A156-2 Grade 1 specifications
•
SDC lever handle styles comply with ADA easy access requirements and CSFM, California State Fire Marshal, Title 19 PTH Power Transfer Hinge
with 5ft Cable
Benefits
•
May be used in new or retrofit construction
•
Building and Fire Life Safety Code Compliance
•
Ideal for high usage environments.
•
Retrofits existing mechanical lock prep
Electrically Operated Single Point Locks
& Latches, 3hr ‘A’ Label Fire Doors
ADA
Compliant
10B Listed for 3hr Fire
Rated Door
CSFM
3774-0324-104
security door controls
www.sdcsecurity.com
E-mail: service@sdcsecurity.com
ISO 9001 : 2000
FM 52705
Ordering Information
Model
Options
A Request-to-Exit output is standard with all models. Turning
the inside lever for egress activates the built in REX output
providing a momentary signal to the access control REX input
for alarm shunt during egress.
All standard locksets are supplied with a 6 pin cylinder with a
Schlage "C" equivalent keyway. Keyed different, with 2 keys.
See keyed alike options below.
Z7250 Failsafe - Outside locked when energized, unlocked by
an access control or key from the outside and rotating
the inside lever provides egress at all times.
Z7252 Failsecure - Outside locked when de-energized.
Unlocked by an access control or key from the outside
and rotating the inside lever provides egress at all times
Optional Strikes
A 4.875" ANSI strike is standard unless specified otherwise
ST2
2.25" ANSI strike with square corners
ST3
2.25" Full lip strike with square corners (for wood frames)
ST4
standard
Optional Latch and Backset Assemblies
The standard latch assembly supplied has a 0.5625"
projection, 2.75" backset and is UL listed for use with single
door openings with 3 hour A Label fire doors. A 0.75" projection
latchbolt must be specified for use with pairs of fire doors.
L75
0.75" latchbolt assembly
B2
2.375" backset latch assembly with 0.5625" latch
Electrical Specifications
Lever Trim
SDC Z7200 HiTower® levers comply with ADA requirements.
The heavy-duty power spring provides smooth and efficient
action and the lever’s clutch mechanism prevents breakage.
Voltage
Dual 12/24VDC Input
Current
600/300mA @ 12/24VDC
REX Output SPDT 3 Amps @ 30VDC
Mechanical Specifications
G
Galaxy
E
Eclipse
Finish
C
605 Bright Brass
H
613 Oil Rubbed Bronze
D
606 Dull Brass
P
625 Bright Chrome
F
611 Bright Bronze
Q
626 Dull Chrome (std.)
G
612 Dull Bronze
Latchbolt
Backset
0.5625" throw
2.75"
Strike
4.875" ANSI A115.2
Door
Thickness
1.75" to 2.125"
To Fire Command Center
600 Power Supply with
Emergency Release
Cylinders
Standard Cylinders
Keyed different is standard and need not be specified
6PKA
7200
Cylindrical Lock
Access
Control
6 Pin Cylinder, keyed alike (optional)
Interchangeable Core
IC6P-KD 6 pin I-Core, small format, keyed different
IC6P-KA 6 pin I-Core, small format, keyed alike
PTH Hinge with
standard 5ft Cable
Options
10B Listed for 3hr Fire Rated Door
DPS Contact
PTH hinge with door positions switch
Optional door status switches are disguised as mounting
screws. Laboratory tested, UL Listing is maintained when door
status switches are specified.
DPS
Door Position Switch SPDT, 500 mA @ 30VDC
PTH Power Transfer Hinge
Door Core Drill Fixture Kit
Features
• UL10B Listed for 3 Hr Fire Doors. If the hinge you are presently using does not bear the F mark, it is not listed for use with fire doors.
• 800,000 cycles. 8 times UL test criteria
• Wire Replacement Warranty
Application
Features
The SDC door core drill fixture provides the best method of
wire preparation for fire rated or non-fire rated particle filled
or solid wood doors to accommodate the installation of electrified locksets, exit devices and hinges while maintaining
door integrity and rating
Installed in the center hinge position of the door, PTH Power
Transfer Hinges provide the concealed wires required between the
door and the frame, for the purpose of powering and monitoring
electric door hardware.
•
Uses Include
•
•
•
•
•
• Electric Lock Power and Control
• Door and Lock Status Signaling
• Request-to-Exit Signaling
Ordering Information
Model
PTH-4
•
Tested by ITS/ Warnock Hersey for field drilling of rated doors Installer may call for inspection of doors to be re-certified after drilling
Allows for drilling from the hinge side without removing the door from the frame
Will drill at 20 degrees from center, up or down, from the hinge to the lock prep on a 3-0 door
Drills doors in 3 minutes
Easy to use, no experience required
Includes special 58 inch evacuator drill bit with custom tool room sharpened end
High speed Delrin bushings ensure long tool life at high speed drilling with little or no noise. Your commercial customers will love the quiet operation in their offices
Four conductor hinge 28 Ga. 1-pair 1 Amp,
1-pair 250 mA, 4.5" x 4.5" standard weight
PTH-10 Ten conductor hinge, 30 Ga. 1-pair 1 Amp,
4-pair, 250 mA, 4.5" x 4.5" standard weight
Consult factory for 3 knuckle, special size, or heavy weight
requirements.
Finish
All base material steel
Q 626 Dull Chrome (standard)
C 605 Bright Brass
P 625 Bright Chrome
7000-DF
Door Core Drill Fixture
H 613 Oil Rubbed Bronze
U 630 Dull Stainless Steel
7000-DB
5/16 Custom Replacement Drill bit
Product Scope 7200 Series
7200 ELECTRIFIED CYLINDRICAL LOCKSETS
Application
Code compliant 7200 Series electrified cylindrical locksets stay latched even when unlocked, maintaining fire door integrity.
This basic ability complies with national code requirements for up to 3-hour fire rated doors, including elevator lobby and
stairwell doors where electromagnetic locks and electric strikes are not permitted. (See Misapplication*, page 2)
For high profile installations that require security with superior aesthetics, failsafe and failsecure electric cylindrical locks
eliminate the need for exposed and vulnerable locking devices, such as electric strikes, magnetic locks and remote request to
exit devices.
Failsafe - 7250
Unlocked when energized, the failsafe cylindrical lock function 7250 is ideal for perimeter door applications. Unlike a
*magnetic lock, the failsafe electrified cylindrical lock function 7250 is never locked from the inside and permits uninhibited
egress at all times by turning the inside manual lever handle. This also eliminates the need for secondary request-to-exit
(REX) devices, such as motion detectors, exit switches and switch bars. When connected to the fire life safety command
center, the lock releases immediately in an emergency, transforming a stairwell or elevator lobby door from a one-way exit into
a two-way exit. This permits re-entry and eliminates the possibility of stairwell entrapment and potential exposure to life threatening smoke inhalation. Additionally, fire fighters are permitted uninhibited access to all floors during an emergency, speeding
life saving and fire extinguishing efforts.
Failsecure - 7252
Unlocked when energized, the failsecure electric cylindrical lock function 7252 is ideal for interior high security applications.
The function 7252 is never locked from the inside and permits uninhibited egress at all times by turning the inside manual
lever handle. This also eliminates reliance on secondary request-to-exit (REX) devices. Battery backup power supplies may be
specified to provide power for operation during power outage.
Facility applications include: Commercial High-Rise Buildings, Industrial and Technology Centers, Health Care, Transportation,
Government and Military Facilities, Museums and Universities.
Access control applications include: Office and work center doors, mantrap doors, stairwell doors, elevator lobby doors,
and exit doors.
Code Compliance
UBC, SBC, BOCA, IBC, IFC, NFPA, UFC, California Building Code, Chicago Building Code. ADA - Americans with Disabilities
Act, 1991. California State Reference Code (formerly CSFM Title 19), Galaxy and Eclipse style lever handles return to within
½” of door face.
Listings
UL Listed: Electrically Controlled Single Point Locks & Latches
CSFM Listed: California State Fire Marshal
Page 1 of 2
security door controls
ISO 9001 : 2000
FM 52705
WHAT’S NEW
Electra™ PRO - SDC Brand
The Z7200 series features an SDC manufactured ANSI Grade 1 Heavy Duty cylindrical lockset that retrofits other mechanical
cylindrical lock brands. Standard features include: SPDT request-to-exit output; clutch for vandal and abuse resistance from
forced lever handles; Dual 12/24VDC input.
Specify Z7200 for new or retrofit applications that require a full-featured lockset with or without request-to-exit outputs,
application versatility and vandal resistance.
Electra™ Mod - Schlage D Lock Electrification
The S7200 and ZS7200 series feature an SDC electrified Schlage D ANSI Grade 1 Heavy Duty cylindrical lockset that retrofits
Schlage or other mechanical cylindrical lock brands. Standard dual 12/24VDC input. Request-to-Exit output is optional and
must be specified.
S7200: The Schlage D cylindrical lock supplied by the distributor to the SDC factory for electrification.
ZS7200: SDC electrified Schlage D cylindrical lock is supplied by SDC.
Specify S7200 and SZ7200 series where Schlage electrified locks are preferred for the retrofit of Schlage or other brand
mechanical locksets.
*Misapplication of Magnetic Locks and Strikes
Magnetic Locks
The use of electromagnetic locks is not recommended for stairwell doors for several reasons. (1) National codes have no
provision for locking the interior side of stairwell doors at any time. (2) When a magnetic lock is energized the door is locked
on the interior and exterior. (3) Egress ability relies upon the proper installation and reliability of a secondary switching device
and/or relay (integrated or external), rather than the inherently safe manual lever egress operation of an electrified lockset. (4)
Codes do not permit the use of a wall mounted exit switch for stairwell door egress. This requires both prior knowledge and
two actions to achieve egress, as opposed to the single natural motion of lever rotation provided by electrified lockset.
Electric Strikes
Electric strikes are not permissible on stairwell doors at any time. Failsafe electric strikes do not keep the door latched when
unlocked, failing to maintain fire door integrity. Failsecure electric strikes are incapable of releasing during an emergency.
Approval of these products by local inspectors for stairwell door applications may not qualify as code compliant and may be
indicative of code misinterpretation
Page 2 of 2
P.O. Box 6219, Westlake Village, CA 91359-6219
3580 Willow Lane, Westlake Village, CA 91361-4921
(805) 494-0622 (800) 413-8783 Fax: (805) 494-8861
Email: service@sdcsecurity.com
www.SDCsecurity.com
security door controls
security door controls
© 2006 Security Door Controls
Product Scope 7200 Series Rev. 8.06
Printed in the U.S.A.
Download