COOPER LIGHTING - METALUX ® DESCRIPTION The WN Series is a specification wraparound luminaire featuring energy efficient performance. The luminaire's clean, low profile design is both appealing and functional. The WN Series utilizes a clear, low brightness, extruded acrylic refractor for high performance and aesthetics. Type Catalog # Project Date Comments The efficient and stylish WN Series is the perfect wraparound for schools, offices and other commercial and retail spaces. Prepared by S P E C I F I C AT I O N F E AT U R E S A…Construction B…Electrical* D…Lens Housing consists of die formed cold rolled steel. Ends formed with the housing for strength and provisions for continuous row aligners. Steel end plates with 7/8" KO and light-seal embossment. Ballast cover easily removed without tools. Ballasts are CBM/ETL Class "P" and are positively secured by mounting bolt. Rotor lock lampholders. UL/CUL listed. Suitable for damp locations. 100% clear acrylic prismatic lens. Sides have inside linear prisms and bottom has pyramidal prisms for low brightness control. C…Finish Multistage, prepaint ensures maximum bonding and rust prevention. A B C WN 217 228T8 232 D 6" [152mm] 2 ' , 4 ' O R 8 ' S U R FA C E T8 LAMPS 2-1/2" [63mm] Commercial Wrap 7-5/8" [194mm] L A M P C O N F I G U R AT I O N S L E N S R E M O VA L 6" [152mm] 1 2-1/2" [63mm] 4-5/8" [117mm] 7-5/8" [194mm] 2 M O U N T I N G D ATA E N E R G Y D ATA Input Watts: EB Ballast & STD Lamps 217 (36) 228T8 (48) 232 (55) 92-1/2" [2349mm] 8' 1-13/16" [46mm] Luminaire Efficacy Rating LER = FW-80 Catalog Number: WN-232A 90-7/8" [2309mm] 44-1/2" [1131mm] 42-15/16" [1090mm] 7-5/8" [194mm] 6" [152mm] 1-1/8" [29mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 3" [76mm] 4-1/2" [114mm] Ceiling Stand-Off Embossments LER = FW-93 Catalog Number: WN-228T8-HB1 41-3/8" [1051mm] 42-3/8" [1076mm] Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.59 88-7/16" [2246mm] 90-7/16" [2297mm] 96" [2440mm] 4' 1-13/16" [46mm] 44-1/2" [1131mm] 42-15/16" [1090mm] Ceiling Stand-Off Ground Screw Bump Embossments 7-5/8" [194mm] 6" [152mm] 1-1/8" [29mm] 2' 1-13/16" [46mm] 1-1/8" [29mm] 7-5/8" [194mm] 6" [152mm] 3" [76mm] 4-1/2" [114mm] 40-7/16" [1027mm] 7/8" [22mm] K.O. (5) 42-7/16" [1078mm] *Reference the lamp/ballast data in the Technical Section for specific lamp/ballast requirements. 20-5/8" [523mm] 19" [483mm] 1" [25mm] 8-3/16" [208mm] 24" [610mm] 1" [25mm] LAMPS CONTAIN MERCURY. DISPOSE ACCORDING TO LOCAL, STATE OR FEDERAL LAWS Safe and convenient means of disconnecting power. 48" [1219mm] COOPER LIGHTING ADF081637 WN T8 P H OTO M E T R I C S Candlepower WN-232-EB81-U Energy Saving Ballast Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 F32T8/35K lamps 3100 lumens Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency = 82.0% Test Report: 134P132 LER = FW-80 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $3.00 Along II 1583 1588 1580 1554 1512 1454 1380 1291 1181 1043 848 602 429 317 240 180 123 62 3 Candlepower WN-228T8-HB81-U Energy Saving Ballast Across ⊥ 1583 1591 1607 1618 1605 1563 1488 1375 1225 1030 809 626 512 444 409 390 369 347 332 45° 1583 1594 1597 1591 1573 1534 1473 1384 1258 1077 851 655 518 413 333 270 223 185 155 Coefficients of Utilization rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 95 82 72 64 57 51 46 42 38 35 32 95 79 67 57 50 44 39 35 31 28 26 95 76 62 52 45 39 34 30 27 24 22 92 83 76 69 64 59 54 50 47 44 41 92 80 70 62 55 49 45 41 37 34 31 92 76 65 56 49 43 38 34 31 28 26 92 73 61 51 44 38 33 29 26 24 22 Zonal Lumen Summary Zone 0-30 0-40 0-60 0-90 90-180 0-180 Lumens 1304 2152 3544 4441 645 5086 %Lamp 21.0 34.7 57.2 71.6 10.4 82.0 Spacing criterion: (II) 1.3 x mounting height, (⊥) 1.4 x mounting height Efficiency = 90.2% Test Report: 134P133 LER = FW-93 Yearly Cost of 1000 lumens, 3000 hrs at .08 KWH = $2.59 Angle 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 Along II 1562 1566 1558 1532 1490 1432 1358 1270 1162 1025 833 590 422 312 236 178 121 61 3 Across ⊥ 1562 1569 1586 1597 1586 1545 1472 1361 1214 1022 803 623 510 442 407 389 367 345 332 45° 1562 1572 1576 1570 1552 1514 1453 1365 1242 1063 841 648 512 408 328 267 221 184 152 Coefficients of Utilization Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 95 86 79 72 66 61 57 52 49 46 43 F28T8 28W lamps 2800 lumens %Fixture 25.6 42.3 69.7 87.3 12.7 100.0 20% 50% 50 30 10 30% 50 30 10 50 85 74 65 58 52 47 42 38 35 32 30 80 69 61 54 49 44 40 36 33 31 29 74 65 57 51 46 41 38 34 32 29 27 85 72 61 53 46 41 36 33 30 27 25 85 69 58 49 42 37 32 29 26 23 21 80 67 58 50 44 39 35 31 28 26 24 80 65 55 47 40 35 31 28 25 22 20 10% 30 10 74 63 54 47 42 37 33 30 27 25 23 74 61 52 45 39 34 30 27 24 22 20 0% 0 72 59 50 42 37 32 28 25 22 20 18 Ty p i c a l VC P Pe r c e n t a g e s Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Height Along 8.5’ 10.0’ 52 58 43 48 36 40 40 46 32 37 Height Across 8.5’ 10.0’ 44 53 31 39 15 21 35 42 17 22 rc rw RCR 0 1 2 3 4 5 6 7 8 9 10 Effective floor cavity reflectance 80% 70% 70 50 30 10 70 50 30 10 105 95 87 79 73 67 62 58 54 50 47 105 91 79 70 62 56 50 46 42 38 35 105 105 87 83 73 68 63 57 55 49 48 42 43 37 38 33 34 29 31 26 29 24 101 91 83 76 70 64 60 55 52 48 45 101 87 77 68 60 54 49 45 41 37 35 101 84 71 61 53 47 42 37 34 31 28 101 81 66 56 48 42 36 32 29 26 24 20% 50% 50 30 10 30% 50 30 10 50 94 81 72 63 57 51 46 42 39 36 33 87 76 67 59 53 48 44 40 37 34 31 81 71 62 56 50 45 41 38 35 32 30 94 78 67 58 51 45 40 36 32 30 27 94 76 63 53 46 40 35 31 28 25 23 87 74 63 55 48 43 38 34 31 28 26 87 71 60 51 44 39 34 30 27 25 22 Zonal Lumen Summary Ty p i c a l VC P Pe r c e n t a g e s Zone 0-30 0-40 0-60 0-90 0-180 Room Size (Ft.) 20 x 20 30 x 30 30 x 60 60 x 30 60 x 60 Lumens 1286 2124 3498 4389 5052 %Lamp 23.0 37.9 62.5 78.4 90.2 %Fixture 25.5 42.0 69.2 86.9 100.0 10% 30 10 Height Along 8.5’ 10.0’ 52 58 43 49 36 40 41 47 33 37 81 69 60 52 46 41 36 33 30 27 25 81 67 57 49 42 37 33 29 26 24 22 0% 0 78 65 54 46 40 35 31 27 25 22 20 Height Across 8.5’ 10.0’ 44 54 31 40 15 21 35 43 17 22 O R D E R I N G I N F O R M AT I O N S A M P L E N U M B E R : W N - 2 3 2 A - U N V- E B 8 1 - U Length Blank=2' or 4' Length 8T=8' (Tandem) Series(1) WN=Commercial Surface Wrap Number of Lamps (2) 2=2 Lamps Voltage (3) 120V=120 Volt 277V=277 Volt 347V=347 Volt UNV=Universal Voltage 120-277 (4) Options GL=Single Element Fuse GM=Double Element Fuse EL=Emergency Installed (5) (Not Included) Wattage 17=17W T8 (24") 28T8=28W T8 (48") (6) 32=32W T8 (48") Lens A=Acrylic Refractor/Lens Packaging Options Ballast Type (3) DEC=Decorative End Cap U=Unit Pack EB8 =T8 Electronic Instant Start. CRA=Continuous Row Total Harmonic Distortion < 10% Aligner No. of Ballast 1 or 2 EB8 /PLUS= T8 Electronic Instant Start. High Ballast Factor >1.13. No. of Total Harmonic Distortion < 20% Ballast 1 or 2 ACCESSORIES REB1= T8 Electronic Instant Start Residential Ballast. SCF=Fixed Stem Set (Specify Length) ER8 =T8 Electronic Program Rapid Start. SCS=Swivel Stem Set (Specify Length) Total Harmonic Distortion < 10% SCA=Adjustable 48” Stem Set No. of Ballast WN-2LT-DEC-ENDS=Decorative End 1 or 2 Caps - 2 Lamps (2 pieces) ER8 /PLUS= T8 Electronic Program Start. WN-CRA=Continuous Row Aligner High Ballast Factor >1.13. (24 pieces) No. of Total Harmonic Distortion < 10% Ballast 1 or 2 HPT8 Ballast HB8 L=T8 Electronic Instant Start. Low Ballast Factor .77 HB8 =T8 Electronic Instant Start. Ballast Factor .88 HB8 N=T8 Electronic Instant Start. Normal Ballast Factor 1.0 HB8 H=T8 Electronic Instant Start. High Ballast Factor 1.15-1.2 HR8 DIM=T8 Electronic Program Start Step Dimming. Ballast Factor .88 HR8 L=T8 Electronic Program Start. Low Ballast Factor .77 HR8 =T8 Electronic Program Start. Ballast Factor .88 HR8 H=T8 Electronic Program Start. High Ballast Factor 1.15-1.2 S H I P P I N G I N F O R M AT I O N (1) (2) NOTES: Steel endplates with 7/8" KO standard for continuous row mounting. 2 point suspension recommended for 2 and 4 lamp models. 3 point suspension (3) recommended for 8 foot tandems. Products also available in non-US voltage and freqeuncies for international markets. 120V must be specified with a residential (4) (5) ballast. Not Available when specifying emergencies, voltage must be specified. A low profile battery pack is required for installation with standard ballast cover (6) (consult Cooper Lighting). When utilizing 28W T8 lamps, HB Ballast must be specified. Other ballast restrictions may apply. Consult your Cooper Lighting Representative for availability and ordering information. For complete product data, reference the Fluorescent Specification binder. Specifications & dimensions subject to change without notice. Consult your Cooper Lighting Representative for availability and ordering information. Catalog No. Wt. WN-217A WN-228T8A 8TWN-228T8A WN-232A 8TWN-232A 6 8 15 8 15 lbs. lbs. lbs. lbs. lbs. Visit our web site at www.cooperlighting.com Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 12/09 ADF081637