Test Report Report No: GZES150801017531

advertisement
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
The follow ing sample(s) w as/w ere submitted and identified on behalf of the client as:
Licensee :
Shenzhen EPQI Technology Co., Ltd.
No. 602 Building 18, WangTang Industrial, XinWei Village XiLi Town, NanShan
District, ShenZhen, China
Manufacturer :
Shenzhen EPQI Technology Co., Ltd.
No. 602 Building 18, WangTang Industrial, XinWei Village XiLi Town, NanShan
District, ShenZhen, China
Model Name :
et100
Product Category :
Low Power Transmitter
Compliance Test
Specification :
System Description Wireless Power Transfer
Volume I: Low Power Part 3 : Compliance Testing Ver1.1.2 June 2013
Interoperability Test
Specification :
Qi Interoperability Test Specification v1.3
(tested by Testronic Laboratories)
Interoperability ID :
IDD10150470T
(issued date: 2015-10-28)
______________________
Ryan Li
Project Reviewer
Safety Laboratory
______________________
Alvin Xie
Project Engineer
This document is issued by the Company subject to its General Conditions of Service,available on request or accessible at http://www.sgs.com/en/Terms-and-Conditions.aspx and, for
electronic format documents, subject to Terms and Conditions for Electronic Documents at http://www.sgs.com/en/Terms-and-Conditions/Terms-e-Document.aspx. Attention is drawn
to the limitation of liability, indemnification and jurisdiction issues defined therein.
Any holder of this document is advised that information contained hereon reflects the Company’s findings at the time of its intervention only and within the limits of Client’s
instructions, if any. The Company’s sole responsibility is to its Client and this document does not exonerate parties to a transaction from exercising all their rights and obligations
under the transaction documents. This document cannot be reproduced except in full, without prior written approval of the Company. Any unauthorized alteration, forgery or
falsification of the content or appearance of this document is unlawful and offenders may be prosecuted to the fullest extent of the law.
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 1 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
1. General Information :
Test lab
Test lab :
SGS-CSTC Standards Technical Services Co., Ltd E&E Lab Guangzhou
Address :
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology
Development District, Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel :
+86 20 8215 5555
Fax :
+86 20 8207 5058
Website :
www.sgs.com
Licensee
Licensee :
Shenzhen EPQI Technology Co., Ltd.
Address :
No. 602 Building 18, WangTang Industrial, XinWei Village XiLi Town,
NanShan District, ShenZhen, China
Telephone :
+86 18002508068
Contact person :
RIVER WANG
e-mail :
18002508068@163.com
General Information of EUT
Product Category :
Low Power Transmitter
The design of Power
transmitter :
A11
Model :
et100
Rated input:
5 Vd.c., 2 A
Additional Info :
Tested together with power adapter
JHD-AP012C-050200AB, 5 Vd.c., 2 A
2. Label :
--
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 2 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
3. Test :
The test was done in the Electrical Safety Laboratory of SGS-CSTC in Guangzhou.
These tests fulfil the requirements of standard ISO/IEC 17025.
When determining the test conclusion, the Measurement Uncertainty of test has been considered.
Ambient Temperature: 20 – 25 degreeC
Relative Humidity: 35 – 65 %
Possible test case verdicts:
Test case does not apply to the test object :
N/A (or N)
Test item does meet the requirement :
P(ass)
Test item does not meet the requirement :
F(ail)
Testing :
Date of receipt of test item :
2015-08-12
Date(s) of performance of tests :
2015-08-12 to 2015-10-10
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 3 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
Clause
Test Name
Measure:
Verdict
CONFORMANCE TO COMMUNICATIONS INTERFACE REQUIREMENTS
Load modulation
1
The BSUT establishes and maintain communications
st
with TPR #3, 1 attempt
--
P
The BSUT establishes and maintain communications
nd
with TPR #3, 2 attempt
--
P
The BSUT establishes and maintain communications
rd
with TPR #3, 3 attempt
--
P
CONFORMANCE TO SYSTEM CONTROL REQUIREMENTS
Selection phase
2
TPR#1A enters power transfer phase at most 3 times.
--
P
Operation Frequency fop1
172,3 kHz
P
Operation Frequency fop2
172,4 kHz
P
Rectified Voltage Vr (TPR#1A)
5,42 V
P
Operation Frequency fop1
173,7 kHz
P
Operation Frequency fop2
173,1 kHz
P
Rectified Voltage Vr (TPR#1B)
7,44 V
P
Operation Frequency fop1
173,2 kHz
P
Operation Frequency fop2
173,5 kHz
P
Rectified Voltage Vr (TPR#1C)
11,2 V
P
Operation Frequency fop1
172,0 kHz
P
Operation Frequency fop2
171,4 kHz
P
Rectified Voltage Vr (TPR#1D)
5,74 V
P
75,4 ms
P
Operation Frequency fop1
172,3 kHz
P
Operation Frequency fop2
172,2 kHz
P
Rectified Voltage Vr
4,16 V
P
Digital ping: Power signal characteristics
3(a)
3(b)
3(c)
3(d)
Digital ping: No response
4
Time interval tping_test
Digital ping: Signal Strength
5
Digital ping: Termination
6
tpingterm1 < 48 ms
34,16 ms
P
6(a)
tpingterm4 < 48 ms
31,04 ms
P
7(a)
tpingterm2 < 29 ms
11,832 ms
P
7(b)
tpingterm3 < 29 ms
12,908 ms
P
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 4 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
Clause
Test Name
Measure:
Verdict
7(c)
tpingterm4 < 29 ms
13,38 ms
P
Identification & Configuration: Packet sequence
8(a)
|Vr1 – Vr2 | < 0,2 V
0,12 V
P
8(b)
timpropersequence < 155 ms
136,8 ms
P
8(c)
Transmitting at least 3 Control Error Packets
--
P
8(d)
Transmitting at least 3 Control Error Packets
--
P
Identification & Configuration: Packet timing
9
tpacket timing < 111.0 ms
102,5 ms
P
10
--
--
--
145,9 ms
P
Identification & Configuration: Communication error
11
tcommerror < 158 ms
Identification & Configuration: Packet content
12
--
--
--
13
tout of range < 245 ms
178,6 ms
P
13(a)
tout of range < 245 ms
178,8 ms
P
13(b)
tcount low < 245 ms
232,2 ms
P
13(c)
tcount high < 245 ms
233,8 ms
P
14
Transmitting at least 3 Control Error Packets
--
P
--
--
Identification & Configuration: Power transfer contract
15
--
Power transfer: Packet sequence
16
tpowerpacket < 256 ms
233 ms
P
16(a)
Transmitting at least 3 times Proprietary Packets
--
P
16(b)
Remains power transfer phase for at least 12 sec
--
P
Power transfer: Packet timing
17(a)
Removed the Power Signal < 1828.0 ms
1668,2 ms
P
17(b)
Removed the Power Signal < 1828.0 ms
1643,0 ms
P
18
Removed the Power Signal < 24028.0 ms
22207,0 ms
P
--
--
Rectified Voltage V1
7,0 V
P
Rectified Voltage V2
7,36 V
P
Rectified Voltage V3
7,44 V
P
Power transfer: Packet content
19
--
Power transfer: Power control
20(a)
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 5 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
Clause
20(b)
21
Test Name
Measure:
Verdict
Rectified Voltage V1_min
--
P
Rectified Voltage V2_max
--
P
Rectified Voltage V1
7,04 V
P
Rectified Voltage V2
6,52 V
P
Rectified Voltage V3
6,52 V
P
Rectified Voltage V2_min
--
P
Rectified Voltage V1_max
--
P
tstabilize ≥ 100 ms
102,3 ms
P
Power transfer: Termination
22
tendpower ≤ 28.0 ms
7,0 ms
P
22(a)
TPR#1A is able to transmit the sequence packets
--
P
CONFORMANCE TO SYSTEM PERFORMANCE REQUIREMENTS
Guaranteed power
23(a)
Rectified Voltage Vr (TPR#1A)
4,25 V
P
23(b)
Rectified Voltage Vr (TPR#1B)
7,11 V
P
23(c)
Rectified Voltage Vr (TPR#1C)
4,27 V
P
23(d)
Rectified Voltage Vr (TPR#1D)
7,62 V
P
23(e)
Rectified Voltage Vr (TPR#1E)
5,05 V
P
23(f)
Rectified Voltage Vr (TPR#06)
5,08 V
P
32,2 degreeC
P
Temperature of Foreign Object #1
50 degreeC @ 600 mA
P
Temperature of Foreign Object #1 (2 mm space)
shut down
P
Temperature of Foreign Object #1 (5 mm space)
shut down
P
Temperature of Foreign Object #1-OC
40 degreeC @ 200 mA
P
Temperature of Foreign Object #1-OC (2 mm space)
shut down
P
Temperature of Foreign Object #1-OC (5 mm space)
shut down
P
Temperature of Foreign Object #2
shut down
P
Temperature of Foreign Object #2 (2 mm space)
shut down
P
Temperature of Foreign Object #2 (5 mm space)
shut down
P
Temperature of Foreign Object #3
shut down
P
Temperature of Foreign Object #3 (2 mm space)
shut down
P
Temperature of Foreign Object #3 (5 mm space)
shut down
P
Thermal Performance
24
o
The Interface Surface temperature < 45 C, or
the temperature rising < 20 K
Foreign Object detection
25(a)
25(b)
25(c)
25(d)
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 6 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
Clause
Test Name
Measure:
Verdict
User interface : object placed
26
tindicate ≤ 0.5 s
35 ms
P
Yes
P
6,58 ms
P
6,32 ms
P
User interface : transfer in progress
27
BSUT enter power transfer or charging indication is
active
User interface : transfer complete
28
tcomplete ≤ 3 s
User interface : fault
29
tcomplete ≤ 3 s
User interface : multiple devices
30
Power transfer or charging indication is active for both
individual Test Power Receivers
--
N/A
--
P
User interface : limited power
31
Limited power indication is active with the load
resistance of TPR #1A at 8 Ω and/or 3.5 Ω
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 7 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
4. Photo document
Details of:
View:
[
] general
[
] front
[
] rear
[
] right
[
] left
[
] top
[
] bottom
[
] Internal
Details of:
View:
[
] general
[
] front
[
] rear
[
] right
[
] left
[
] top
[
] bottom
[
] Internal
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch
198 KEZHU Road, SCIENTECH Park Guangzhou Economic & Technology Development District,
Guangzhou, Guangdong, CHINA. Zip Code: 510663
Tel: +86 20 8215 5555 Fax: +86 20 8207 5058
WPC_LP_BS_A
Page 8 of 9
_______________________________________________________________________
Test Report
Report No: GZES150801017531
Date: 2015-11-02
Details of:
View:
[
] general
[
] front
[
] rear
[
] right
[
] left
[
] top
[
] bottom
[
] Internal
- - - End of Report - - -
SGS-CSTC Standards Technical Services Co., Ltd. Guangzhou Branch