Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers Overview Overview Features Designed to provide branch and feeder circuit protection in industrial control panels, this line of Molded Case Circuit Breakers supplies protection against overload in conductors and short circuit in connected equipment such as motors. They are UL listed for installation in UL 508 control panels. Their small size, in relation to standard circuit breakers or other comparable devices, saves panel space. Four frame sizes and all standard accessories are available. Listings • UL 489 MCCB, File: E7819 • Field-installed accessories: UL file E64983 • CSA 22.2 No.5, File: 43556 • IEC 157-1 • NEMA Standards Pub. No. AB1-1993 • UL489 listed performance for branch circuit overcurrent protection and disconnecting means • Patented contact conductor designs featuring high-speed “blow-open” action, providing superior performance when high level fault currents produce extra-ordinary electromechanical forces • Advanced arc extinguishing technology • Toggle handle provides three positions (on/off/tripped) along with visual indicators • Manufactured in ISO 9000 certified facilities • HACR (heating, air conditioning and refrigeration) rated • G-Frame and F-Frame breakers are suitable for reverse feed • K-Frame and L-Frame breakers include 3-pole adjustable magnetic trip. Manufactured by Eaton Corporation Note: These parts available for sale to North American locations only. Molded Case Circuit Breakers Technical Specifications UL 489 Interrupting Ratings Volts Type Federal (rms Symmetrical Amperes) (kA) Circuit Breaker Ampere Rat- No. of Specification Volts AC (50/60 Hz) Volts DC Type ing at 40°C Poles AC DC Trip* W-C-375b G-Frame F-Frame K-Frame L-Frame 240 480 600 250** 15 -100 3 480 250 N.I.T.U 13b 65 22 – 10 60 - 225 3 600 250 N.I.T.U 22a 65 35 18 10 250 - 400 3 600 250 I.T.U 23a 65 35 25 10 400 - 600 3 600 250 I.T.U 23a 65 35 25 22 *Note: N.I.T.U denotes non-interchangeable trip unit. I.T.U denotes interchangeable trip unit. **Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker Molded Case Circuit Breakers Part Numbering System G 3P - 020 - AUX Accessory Description Code AUX: auxiliary contact STAC: shunt trip AC STDC: shunt trip DC UVAC: undervoltage release n e oltage elea e Amp Rating 3 Pole Molded Case Circuit Breaker Series (by frame size) G: 15 to 100 Amp F: 60 to 225 Amp K: 250 to 400 Amp L: 400 to 600 Amp Book 3 (14.3) eCP-34 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 60 - 225 Amp F-Frame F-Frame circuit breakers are available as a single unit, or with accessories preinstalled only. Accessories are not field installable on this frame size. Company Information Terminal Blocks This frame size is suitable for reverse feed use. All breakers include base mounting hardware for panel mount applications. F3P-060 F3P-070 F3P-080 F3P-090 F3P-100 F3P-125 F3P-150 F3P-150-AUX F3P-150-STAC F3P-150-STDC F3P-150-UVAC F3P-200 FHMVD12B F3P-175 F3P-200 F3P-200-AUX F3P-200-STAC F3P-200-STDC F3P-200-UVAC F1S03C F3P-225 Price Pre-Installed Accessories* Description $572.00 $612.25 $612.25 $577.50 $612.25 $612.25 $612.25 $673.00 $673.00 $673.00 $673.00 Molded case circuit breaker with nonadjustable thermal magnetic trip; line and load lug terminals included. Molded case circuit breaker with nonadjustable thermal magnetic trip; line and load lug terminals included. Molded case circuit breaker with non$612.25 adjustable thermal magnetic trip; line and load lug terminals included. $612.25 $673.00 Molded case circuit breaker with non$673.00 adjustable thermal magnetic trip; line $673.00 and load lug terminals included. $673.00 Molded case circuit breaker with non$612.25 adjustable thermal magnetic trip; line and load lug terminals included. Ampere Voltage Interrupt Rating Capacity None None None None None None None auxiliary contact, SPDT 120 VAC shunt trip 24 VDC shunt trip 120 VAC undervoltage release 60 70 80 90 100 125 None 175 None auxiliary contact, SPDT 120 VAC shunt trip 24 VDC shunt trip 120 VAC undervoltage release 200 None 225 M12 Junction Blocks Panel Interface Connectors Wiring Duct 150 240VAC 480VAC 600VAC 250VDC** 65kA 35kA 18kA 10kA Power Supplies DC Converters $73.25 $104.50 $118.25 $320.25 $347.25 $52.00 $77.25 NEMA 1/12 rotary handle for F-frame. Position indicating. Lock-off feature. Shaft length: 12” NEMA 4/4X rotary handle for F-frame. Position indicating. Lock-off feature. Shaft length: 12” NEMA 4/4X rotary handle for F-frame. Position indicating. Lock-off feature. Shaft length: 24” NEMA 1/12 flex shaft cable operator for F-frame. Flange mountable. Lockable. Cable length: 3’ NEMA 1/12 flex shaft cable operator for F-frame. Flange mountable. Lockable. Cable length: 6’ Multi-wire connector to allow 6 wires to be connected to the F-frame. UL for copper only. 14-6 AWG. Package of 3 Replacement lug kit for F-frame. Package of 3 F-Frame Electrical Ratings 1,2 Frequency F-Frame Auxiliary Switch 1 125 VDC DC 0.504 250 VDC DC 0.254 F-Frame Shunt Trip F-Frame Undervoltage Release Mechanism 6 2500 1. Endurance: 5000 electrical operations plus 4000 mechanical operatons. 2. Pigtail wire size: 18 AWG (0.82 mm2) 3. Use in electronice circuit of 100 micro-amperes and 15 VDC minimum. 4. Non-inductive load Supply Min Operating VA Voltage Voltage 120 VAC 36 VAC 24 VDC 9 VDC 570 400 AWG Wire Range Specifications Dropout Volt- Pickup Supply age Voltage VA Voltage Min Max Maximum 120 VAC 44.5 VAC 77.0 VAC 93.5 VAC 1.5 Circuit Ampere Wire AWG Wire Metric Wire Breaker Rating Type Range Range mm2 F-Frame 60 - 100 Cu/AI 125 - 225 14 - 1/0 4 - 4/0 2.5 - 50 25 - 95 Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Dielectric Max Notes Amperes Withstand Voltage 125 VAC 50/60 Hz 600 VAC 50/60 Hz 3 Transformers and Filters Tools Description Max Volts Wire Wire Management Products Price 3TA225FD Cable Ties Bulk Multi-conductor Cables F-Frame Accessory Selection Guide 3TA150F6K Multi-wire Connectors Sensor Cables and Connectors *Note: Available accessories are pre-installed on G-Frame and F-Frame Molded Case Circuit Breakers. They are not field installable or interchangeable. **Note: For DC or 1-phase AC applications, use the two outside poles of the 3-pole circuit breaker Part Number FHMVD12B HM1R12X HM1R24X F1S03C F1S06C 3TA150F6K 3TA225FD Wiring Accessories ZIPLink Connection System F-Frame Series Three Pole Molded Case Circuit Breakers Part Number Power Distribution Blocks Circuit Protection eCP-37 Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 60 Amp F-Frame 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 500 400 40 50 60 70 8090 200 30 100 20 2 HOURS Circuit Breaker Time/Current Curves F3P 2 HOURS 5 6 7 8 9 10 10,000 300 CURRENT IN AMPERES 60A 60 Amperes 1 HOUR For application and coordination purposes only . Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (60˚C up to 125 amps, 75˚C above 125 amps) per terminal. Tested in open air with current in all poles. 3,000 2,000 1 HOUR 5,000 5,000 3,000 2,000 Maximum AC Volts: 600 at 60 Hz Maximum DC Volts: 250 Breaker Rating Continuous Amperes 60 Amps 1,000 Interrupting Rating (UL/CSA Listed) Breaker Symmetrical RMS Amperes (KA) @ 240 VAC @ 480 VAC @ 600 VAC Type 500 F3P 65 1,000 Instantaneous Trip Amperes See Curve 35 18 Amps (KA) 250VDC 500 10 300 300 200 1 Single pole test data at 25˚C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circuit breakers. 200 100 100 50 50 30 30 20 20 Minimum Maximum 5 5 3 3 2 2 1 1 .5 .5 .3 .3 .2 .2 .1 .1 TIME IN SECONDS 10 .05 TIME IN SECONDS 10 .05 .03 .03 Maximum Interrupting Time .02 .02 .01 .01 Interrupting Rating Determines End of Curve (See Above) .005 .003 .002 .005 .003 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 40 50 60 70 8090 500 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 1 MINUTE 1 MINUTE Maximum Single Pole Trip Times at 25°C 1 .001 CURRENT IN AMPERES Book 3 (14.3) eCP-38 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 70 Amp F-Frame 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 500 400 40 50 60 70 8090 200 30 100 20 300 CURRENT IN AMPERES 70A 2 HOURS Circuit Breaker Time/Current Curves F3P 2 HOURS 5 6 7 8 9 10 10,000 70 Amperes 1 HOUR For application and coordination purposes onl y. Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (60˚C up to 125 amps, 75˚C above 125 amps) per terminal. Tested in open air with current in all poles. 3,000 2,000 3,000 1 HOUR 5,000 5,000 Breaker Rating Continuous Amperes 70 Amps Instantaneous Tr ip Amperes See Curve Interrupting Rating (UL/CSA Listed) Breaker Symmetrical RMS Amperes (kA) @ 240 V AC @ 480 V AC @ 600 V AC Type 500 F3P 65 35 18 Amps (kA) @250 V DC 1 Single pole test data at 25˚C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circuit breakers. 500 M12 Junction Blocks Panel Interface Connectors 200 100 100 50 50 30 30 20 Wiring Duct Cable Ties Wire Bulk Multi-conductor Cables 20 Minimum ZIPLink Connection System Sensor Cables and Connectors 1 MINUTE 1 MINUTE Maximum Single Pole Trip Times at 25°C 1 Wiring Accessories 1,000 300 200 Power Distribution Blocks Multi-wire Connectors 10 300 Terminal Blocks 2,000 Maximum AC Vo lts: 600 at 60 Hz Maximum DC Vo lts: 250 1,000 Company Information Wire Management Products Maximum 10 10 5 5 DC Converters 3 3 2 2 Transformers and Filters Power Supplies TIME IN SECONDS Circuit Protection 1 .5 .5 Test Equipment Enclosures TIME IN SECONDS 1 Tools .3 .3 .2 .2 .1 .1 Safety: Electrical Components .05 Safety: Protective Wear .05 .03 Enclosure Climate Control .03 Terms and Conditions Maximum Interrupting Time .02 .02 .01 .01 Interrupting Rating Determines End of Curve (See Above) .005 .003 .002 .003 .001 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 40 50 60 70 8090 500 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 .005 CURRENT IN AMPERES Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-39 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 80 Amp F-Frame 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 500 400 200 40 50 60 70 80 90 100 30 2 HOURS Circuit Breaker Time/Current Curves 2 HOURS 10,000 20 300 CURRENT IN AMPERES 80A 5 6 7 8 9 10 F3P 80 Amperes 1 HOUR For application and coordination purposes only. Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (60˚C up to 125 amps, 75˚C above 125 amps) per terminal . Tested in open air with current in all poles. 3,000 2,000 1 HOUR 5,000 5,000 3,000 2,000 Maximum AC Vo lts: 600 at 60 Hz Maximum DC Vo lts: 250 Breaker Rating Continuous Amperes 80 Amps 1,000 Interrupting Rating (UL/CSA Listed) Breaker Symmetrical RMS Amperes (kA) @ 240V. AC @ 480 V AC @ 600VAC Type 500 F3P 65 1,000 Instantaneous Tr ip Amperes See Curve 35 18 Amps (kA) @ 250V DC 300 300 200 Maximum Single Pole Trip Times at 25°C 1 1 Single pole test data at 25˚C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circui t breakers. 200 100 100 50 50 30 30 20 20 10 10 5 5 3 3 Maximum 2 2 1 1 .5 .5 .3 .3 .2 .2 .1 .1 .05 TIME IN SECONDS Minimum TIME IN SECONDS 1 MINUTE 1 MINUTE 500 10 .05 .03 .03 Maximum Interrupting Time .02 .02 .01 .01 Interrupting Rating Determines End of Curve (See Above) .005 .003 .002 .003 6000 7000 8000 9000 10000 5000 4000 3000 2000 50 60 70 80 90 600 700 800 900 1000 40 500 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 .005 .001 CURRENT IN AMPERES Book 3 (14.3) eCP-40 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 90 Amp F-Frame 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 500 400 40 50 60 70 8090 300 30 200 20 100 90A 2 HOURS Circuit Breaker Time/Current Curves 2 HOURS 5 6 7 8 9 10 10,000 CURRENT IN AMPERES F3P 90 Amperes 1 HOUR For application and coordination purposes only . Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (60˚C up to 125 amps, 75˚C above 125 amps) per terminal. Tested in open air with current in all poles. 3,000 2,000 3,000 1 HOUR 5,000 5,000 Breaker Rating Continuous Amperes 90 Amps Instantaneous Tr ip Amperes See Curve Interrupting Rating (UL/CSA Listed) Breaker Symmetrical RMS Amperes (kA) @ 480 V AC @ 600 V AC Type @ 240 V AC 500 F3P 65 35 18 Amps (kA) @ 250 VDC 1 Single pole test data at 25˚C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circui t breakers. ZIPLink Connection System Sensor Cables and Connectors M12 Junction Blocks 500 Panel Interface Connectors 200 100 100 50 50 30 30 20 20 10 10 Wiring Duct Cable Ties 1 MINUTE 1 MINUTE Maximum Single Pole Trip Times at 25°C 1 Wiring Accessories 1,000 300 200 Power Distribution Blocks Multi-wire Connectors 10 300 Terminal Blocks 2,000 Maximum AC Vo lts: 600 at 60 Hz Maximum DC Vo lts: 250 1,000 Company Information Wire Bulk Multi-conductor Cables Wire Management Products Power Supplies Minimum Maximum DC Converters 3 3 2 2 Transformers and Filters TIME IN SECONDS 5 5 Circuit Protection 1 .5 .5 Test Equipment TIME IN SECONDS 1 Tools .3 .3 Enclosures .2 .2 Enclosure Climate Control .1 .1 Safety: Electrical Components .05 Safety: Protective Wear .05 .03 .03 Maximum Interrupting Time .02 .01 .01 Interrupting Rating Determines End of Curve (See Above) .005 .003 .002 .005 .003 .001 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 40 50 60 70 8090 500 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 .02 CURRENT IN AMPERES Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-41 Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. 4000 3000 2000 500 600 700 800 900 1000 400 30 40 50 60 708090 300 20 200 5 6 7 8 910 CURRENT IN AMPERES 2 HOURS Circuit Breaker Time/Current Curves F3P 100 Amperes ¨ 5,000 3,000 2,000 Breaker Rating Continuous Amperes 100 Amps 1,000 3,000 2,000 Instantaneous Trip Amperes See Curve Interrupting Rating (UL/CSA Listed) Amps (KA) Breaker Symmetrical RMS Amperes (KA) @ 480 VAC @ 600 VAC @ 250VDC Type @ 240 VAC 500 F3P 65 35 18 1,000 500 10 300 300 200 * Single pole test data at 25°C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circuit breakers. Maximum Single Pole Trip Times at 25°C * 200 100 100 50 50 30 30 20 20 10 10 Minimum Maximum 5 3 3 2 2 1 1 .5 .5 .3 .3 .2 .2 .1 .1 .05 TIME IN SECONDS TIME IN SECONDS 5 1 MINUTE 1 MINUTE 5,000 For application and coordination purposes only Based on 40°C ambient, cold start. Connected with four . (4) feet of rated wire (60°C up to 125 amps, 75°C above 125 amps) per terminal Tested in open air with current in all poles. Maximum AC Volts: 600 at 60 Hz Maximum DC Volts: 250 1 HOUR 1 HOUR 2 HOURS 10,000 100 100A 5000 6000 7000 8000 9000 10000 3P Series Molded Case Circuit Breakers 100 Amp F-Frame .05 .03 .03 Maximum Interrupting Time .02 .02 .01 .01 Interrupting Rating Determines End of Curve (See Above) .005 .003 .002 5000 6000 7000 8000 9000 10000 4000 3000 CURRENT IN AMPERES 2000 500 600 700 800 900 1000 40 50 60 708090 400 30 300 20 200 5 6 7 8 9 10 .003 .002 100 .001 .005 .001 Book 3 (14.3) eCP-42 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 125 Amp F-Frame 2 HOURS 6000 7000 8000 9000 10000 5000 4000 Circuit Breaker Time/Current Curves 125 Amperes F3P Circuit Breakers For application and coordination purposes only 5,000 Based on 40°C ambient, cold start. Connected with four (4) feet of rated wire (60°C up to 125 amps, 75°C above 125 amps) per terminal. Tested in open air with current in all poles. . 5,000 3,000 3,000 Maximum AC Volts: 600 at 60 Hz Maximum DC Volts: 250 2,000 Power Distribution Blocks Wiring Accessories 1 HOUR 1 HOUR 3000 2000 600 700 800 900 1000 500 400 40 50 60 70 8090 300 30 200 20 CURRENT IN AMPERES Terminal Blocks 2 HOURS 5 6 7 8 9 10 10,000 100 125A Company Information ZIPLink Connection System 2,000 Multi-wire Connectors Breaker Rating 1,000 Sensor Cables and Connectors Instantaneous Trip Amperes 1,000 See Curve Continuous Amperes 125 Amps Interrupting Rating (UL/CSA Listed) 500 Breaker Type @ 300 F3P 1 200 65 35 18 Amps (KA) VAC 250 VDC 10 Single pole test data at 25°C based on NEMA Procedures (AB 4-1991) for verifying performance of molded case circuit breakers. Maximum Single Pole Trip Times at 25°C 1 100 M12 Junction Blocks 500 300 Panel Interface Connectors 200 Wiring Duct 100 50 50 30 30 20 20 10 Cable Ties 1 MINUTE 1 MINUTE Symmetrical RMS Amperes (KA) @ 480 VAC @ 600 240 VAC Wire Bulk Multi-conductor Cables Wire Management Products 10 Power Supplies Minimum Maximum 5 3 3 2 2 DC Converters TIME IN SECONDS TIME IN SECONDS 5 Transformers and Filters Circuit Protection 1 1 .5 .5 Test Equipment .3 .3 Enclosures .2 .2 Enclosure Climate Control .1 .1 Safety: Electrical Components .05 .03 Maximum Interrupting Time .02 .01 Terms and Conditions .02 .01 .005 Interrupting Rating Determines End of Curve (See Above) .003 .002 .005 .003 .001 6000 7000 8000 9000 10000 5000 4000 3000 2000 600 700 800 900 1000 40 50 60 70 8090 500 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 Safety: Protective Wear .05 .03 CURRENT IN AMPERES Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection Tools eCP-43 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 150 Amp F-Frame T ype F3P 150 A m peres 6000 7000 8000 9000 10000 5000 Circuit Breaker Time/Current Curves ¨ F3P Circuit Breaker 150 Amperes 5,000 5,000 For application and coordination purposes only. Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (60˚C up to 125 Amps, 75˚C above 125 Amps) per terminal. Tested in open air with current in all poles. . 3,000 2,000 3,000 1 HOUR 1 HOUR 4000 3000 2000 600 700 800 900 1000 500 400 40 50 60 70 8090 300 30 200 20 2 HOUR S 5 6 7 8 9 10 CURRENT IN AMPERES 2 HOUR S 10,000 100 150A 2,000 M ax im u m A C Vo l t s : 600 at 60 Hz M ax im u m D C Vo l t s : 250 Breaker Rating Continuous A mperes 150 A m ps 1,000 500 M axim um Single Po leTr ip Tim es at 25˚C 1 300 500 10 300 Single pole test data at 25˚C based on NEMA (AB4-1991) for verifying performance of molded case circuit breakers. 200 100 50 50 30 30 20 20 10 10 M inim um M axim um 1 MINU TE 1 MINU TE Am ps (k A) @250VDC 1,000 100 5 5 3 3 2 2 1 1 .5 .5 .3 .3 .2 .2 .1 .1 .05 .05 .03 TIME IN SECONDS TIME IN SECONDS Interrupting Rating (UL/CSA listed) B reaker S ym m etrical RM S A mperes (k A) @ 480 VAC @ 600VAC Type @240VAC F3 P 65 35 18 1 200 Instantaneous Trip Amperes See Curve .03 M axim um Interrupting Tim e .02 .02 .01 .01 Interrupting Rate determines End of Curve .005 .003 (See A bove) .002 .003 6000 7000 8000 9000 10000 5000 4000 3000 2000 500 40 50 60 70 8090 600 700 800 900 1000 30 400 20 300 5 6 7 8 9 10 200 .002 100 .001 .005 .001 C urve No. CURRENT IN AMPERES Book 3 (14.3) eCP-44 Octo ber 1997 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers 175 - 225 Amp F-Frame 2 HOURS Circuit Breakers Time/Current Curves Molded-Case Circuit Breakers 5,000 3,000 Maximum AC Volts: 690 at 50/60 Hz Maximum DC Volts: 250 3,000 1 HOUR Catalog Types F3P Circuit Breakers For application and coordination purposes only . Based on 40˚C ambient, cold start. Connected with four (4) feet of rated wire (75˚C) per terminal. Tested in open air with current in all poles. 2,000 À 1,000 Multi-wire Connectors 2,000 Instantaneous Pick-up, Amperes 2400 2400 2400 Sensor Cables and Connectors 1,000 Interrupting Ratings Breaker Type Maximum Single Pole Trip Times at 25˚C Á 300 480 VAC 35 600 VAC 18 250 VAC 10 500 À Fixed Inverse Ð Time Overcurrent Release. Á Single Pole Test Data at 25 ˚C based on NEMA Procedures (AB 4-1991) for verifying performances of Molded Case Circuit Breakers. Â Total Operation Time. Ã Interrupting Rating Determines End of Curve. In this interruption region: The curve is drawn for I n = 200A. For I n ¹ 200A, the end points in this region are displaced along the current-axis by a factor (200A/I n ) 300 Panel Interface Connectors 200 Wiring Duct Notes: 200 Cable Ties 100 100 50 50 30 Wire 1 MINUTE 1 MINUTE 65 F3P 500 M12 Junction Blocks Symmetrical RMS Amperes (kA), Icu 240 VAC Power Distribution Blocks ZIPLink Connection System 1 HOUR 5,000 Breaker Rating In Amperes 175 200 225 Terminal Blocks Wiring Accessories 600 700 800 900 1000 500 400 300 200 60 70 80 90 100 50 5 6 7 8 9 40 4 20 3 10 2 2 HOURS 5 6 7 8 91 10,000 30 CURRENT IN MULTIPLES of I n (AMP) 175-225A Company Information Bulk Multi-conductor Cables 30 Maximum Trip Time 20 20 10 10 Wire Management Products Power Supplies 5 5 3 3 TIME IN SECONDS 2 Minimum Trip Time 1 1 Transformers and Filters TIME IN SECONDS 2 DC Converters Circuit Protection Tools 175 A .5 .5 Test Equipment .3 Enclosures 200 A .3 225 A .2 .2 .1 .1 .05 Safety: Electrical Components .05 .03 Safety: Protective Wear .03 Â Ã .02 Terms and Conditions .02 .01 .01 .005 .005 .003 .003 .002 .002 600 700 800 900 1000 500 400 300 200 .001 50 5 6 7 8 9 60 70 80 90 100 4 40 3 30 2 20 1 10 .001 Enclosure Climate Control CURRENT IN MULTIPLES of In (AMP) Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-45 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers – Dimensions 15 - 100 Amp G-Frame inches(mm) 60 - 225 Amp F-Frame inches(mm) Book 3 (14.3) eCP-50 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories Rotary Handle A universal rotary handle is available for each frame size of molded case circuit breaker. The handles are suitable for use with NEMA 1, 12, 4 or 4x enclosures. Features include: • Large handle easily accommodates gloves • Global ON/OFF markings (I/ON, O/OFF) and TRIP indication on handle • Access Handle Lock-Off by pressing arrow on handle insert • Door interlock and defeater • Metal shaft and base • Pipe valve operation (ON=Vertical, OFF=Horizontal) with 90 degree rotation • UL 489, IEC 947-1/-2, CSA GHMVD12B Rotary Handle Accessory Selection Guide Part Number Price Description $66.25 NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 6” GHMVD06B GHMVD12B FHMVD12B HM1R12X $73.25 NEMA 1/12 black rotary handle for G-Frame MCCB. Shaft length: 12” $73.25 NEMA 1/12 black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R12X $104.50 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 12” HM1R24X $118.25 NEMA 4/4X black rotary handle for F-Frame MCCB. Shaft length: 24” KHMVD12B $106.50 NEMA 1/12 black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R12X $129.25 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM3R24X $143.75 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24” LHMVD12B $122.50 NEMA 1/12 black rotary handle for L-Frame MCCB. Shaft length: 12” HM4R12X $167.50 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 12” HM4R24X $176.50 NEMA 4/4X black rotary handle for K-Frame MCCB. Shaft length: 24” Flex Shaft™ Flexible Handle Meeting crucial time limits for shutdown procedures is easier with an externally mounted handle. The flexible handle makes it possible to operate the circuit breaker externally, and can be used in enclosures of varying depths and heights. It can be used with NEMA 1, NEMA 3R and NEMA 12 enclosures, and accepts up to three padlock shackles. Note: A minimum bending radius of four inches is necessary for proper operation. Flexible Handle Accessory Selection Guide Part Number Price Description $286.75 NEMA 1/12 flex shaft cable operator for G-Frame MCCB. Cable length: 3’ F0S03C F0S03C F0S06C $320.25 NEMA 1/12 flex shaft cable operator for G-Frame MCCB. Cable length: 6’ F1S03C $320.25 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 3’ F1S06C $347.25 NEMA 1/12 flex shaft cable operator for F-Frame MCCB. Cable length: 6’ F3S03C $381.00 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 3’ F3S06C $403.25 NEMA 1/12 flex shaft cable operator for K-Frame MCCB. Cable length: 6’ F4S04C $437.25 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 4’ F4S06C $504.50 NEMA 1/12 flex shaft cable operator for L-Frame MCCB. Cable length: 6’ Book 3 (14.3) eCP-52 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories Auxiliary Contact Note:Field installable auxiliary contacts are not available for the G and F frame breakers. For G and F frame auxiliary contacts, order breakers with -AUX as part of the part number. Please see G and F-frame sections for available selections. Sensor Cables and Connectors Description $193.50 Field installable auxiliary contact for L-Frame MCCB, SPDT, 18” pigtail leads 50/60 Hz DC DC 6 0.50 Max Frequency Max Dielectric Volts Amperes Withstand Voltage 600 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. Pigtail wire size: 18 AWG (0.82 mm²) 3. Non-inductive load 3 2500 0.253 L-Frame Auxiliary 125 Switch 250 50/60 Hz 6 DC 0.503 DC 3 M12 Junction Blocks 2500 0.25 Cable Ties Wire Bulk Multi-conductor Cables L-Frame Electrical Ratings 1,2 Notes Multi-wire Connectors Wiring Duct $188.75 Field installable auxiliary contact for K-Frame MCCB, SPDT, 18” pigtail leads K-Frame Electrical Ratings 1,2 ZIPLink Connection System Panel Interface Connectors Auxiliary Contact Accessory Selection Guide A1X3PK A1X4PK 600 Power Distribution Blocks Wiring Accessories Part Number Price K-Frame 125 Auxiliary Switch 250 Terminal Blocks The auxiliary contact provides circuit breaker contact status information by monitoring the position of the molded cross bar which contains the moving contact arms. The auxiliary switch is used for remote indication and interlock system verification, and consists of one SPDT switch housed in a plug-in module. Each SPDT switch has one ‘a’ and one ‘b’ contact. When the circuit breaker contacts are open, the ‘a’ contact is open and the ‘b’ contact is closed. A1X3PK Max Frequency Max Dielectric Volts Amperes Withstand Voltage Company Information Notes 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. Pigtail wire size: 18 AWG (0.82 mm²) 3. Non-inductive load Wire Management Products Power Supplies DC Converters Transformers and Filters Circuit Protection Undervoltage Release This product monitors a voltage (typically a line voltage) and trips the circuit breaker when the voltage falls to between 70% and 35% of the solenoid coil rating. It consists of a continuous rated solenoid, with a plunger and tripping lever mounted in a plug-in module. Note: The undervoltage release is a pre-installed accessory on G-Frame and F-Frame breakers. Undervoltage Release Accessory Selection Guide UVH3LP21K Part Number UVH3LP08K UVH4LP08K UVH3LP21K UVH4LP21K Dropout Pickup Supply Voltage Voltage VA Notes Voltage Min Max Max K-Frame Undervolt24 VDC 8.4 16.8 20.4 age Release 2 Mechanism 110 VAC 120 VAC2 44.5 77.0 93.5 127 VAC2 3.1 1.8 2.1 2.4 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. 50/60 Hz Price $383.25 $386.00 $383.25 $409.25 Field installable 110 - 127 VAC undervoltage release for K-Frame MCCB Field installable 110 - 127 VAC undervoltage release for L-Frame MCCB Field installable 24 VDC undervoltage release for K-Frame MCCB Field installable 24 VDC undervoltage release for L-Frame MCCB Dropout Pickup Supply Voltage Voltage VA Notes Voltage Min Max Max 120 VAC2 44.5 77.0 127 VAC2 93.5 3.1 1.8 2.1 2.4 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. 50/60 Hz Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection Test Equipment Enclosures Enclosure Climate Control Safety: Electrical Components Description L-Frame Undervoltage Release 24 VDC 2 8.4 16.8 20.4 Mechanism 110 VAC Tools eCP-53 Safety: Protective Wear Terms and Conditions Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers – Accessories Field Mountable Accessories Shunt Trip The Shunt Trip provides remote controlled tripping of the circuit breaker. Consisting of an intermittent rated solenoid with a tripping plunger and a cutoff switch assembled to a plug-in module, shunt trip coils are designed to be applied at specific AC or DC voltages. Shunt Trip Accessory Selection Guide Part Number SNT3P11K SNT4RP11K SNT3P04K SNT4RP03K Price $383.25 $409.25 $383.25 $409.25 Description Field installable 110/240 VAC / 110/125 VDC shunt trip for K-Frame MCCB. Field installable 110/240 VAC shunt trip for L-Frame MCCB Field installable 12/24 VAC/DC shunt trip for K-Frame MCCB Field installable 12/24 VAC/DC shunt trip for L-Frame MCCB SNT3P04K Supply Min Supply Min Operating VA VA Notes Voltage Voltage Voltage Operating Voltage VAC 50/60 Hz K-Frame 12 24 Shunt 110 Trip 120 127 208 220 240 9 60 VDC 45 200 100 120 140 420 470 550 12 24 110 120 125 – – – 8.4 77 77 77 – – – 35 170 110 130 140 – – – 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 8 ms Supply Min Supply Min VA Voltage Operating VA Notes Voltage Operating Voltage Voltage VAC 50/60 Hz L-Frame Shunt Trip 12 24 110 120 127 208 220 240 9 60 VDC 45 200 100 120 140 420 470 550 12 24 – – – – – – 9 – – – – – – 35 170 – – – – – – 1. Endurance: 5000 electrical operations plus 1000 mechanical operatons. 2. Approx. unlatching time: 6 ms Approx. total circuit breaker contact opening time: 18 ms Book 3 (14.3) eCP-54 Circuit Protection 1 - 8 0 0 - 633 - 0 4 0 5 Prices as of April 27, 2016. Check Web site for most current prices. 3P Series Molded Case Circuit Breakers – Accessories Company Information Terminal Blocks Field Mountable Accessories Power Distribution Blocks Six-wire Connector Wiring Accessories This is a field installable multi-wire connector which allows six wires to be connected to the load side (OFF) end terminals. It is used to distribute the load from the circuit breaker to multiple devices without the use of separate distribution terminal blocks. UL listed for copper only as used on the load side (OFF) end. Includes mounting hardware, insulators and tin-plated aluminum connectors. ZIPLink Connection System Multi-wire Connectors Sensor Cables and Connectors Six-wire Connector Accessory Selection Guide Part Number 3TA100G6K 3TA150F6K Price $52.00 $52.00 Description For G-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper For F-Frame MCCBs. Pkg. of 3. Wire size: 14 - 6 AWG, copper 3TA100G6K M12 Junction Blocks Panel Interface Connectors Replacement Lug Kit Wiring Duct Line and load terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. Replacement lugs will accept wire types Cu/AI as standard. Cable Ties Wire Bulk Multi-conductor Cables Replacement Lug Kit Accessory Selection Guide Part Number Price 3TA225FD $77.25 3TA401K $81.00 3TA603LDK $100.25 Description Replacement lug kit for F-Frame MCCB. Wire range (1) #4-4/0 (25-95 mm²). Package of (3) terminals. Replacement lug kit for K-Frame MCCB. Wire range (2) 2/0-250 kcmil or (1) 2/0-500 kcmil (70-240 mm²). 3-pole kit (one terminal per pole and one terminal cover). Replacement lug kit for L-Frame MCCB. 3-pole kit (one terminal per pole and one terminal cover). Wire range 400-500 AWG (185-240 m²), 2 conductors. Wire Management Products 3TA401K Power Supplies DC Converters Note: G-frame terminals are factory-installed only. No replacement terminals available. Transformers and Filters Din Rail Mounting Clip Circuit Protection Din Rail Mount Clip Accessory Selection Guide Part Number ­­­GDIN Price $9.00 GDIN Type C361 door interlocking safety handle kits are designed for use with AutomationDirect 3P series MCCBs and flexible handle, when mounted in an SDN12, or equivalent, enclosure. These handles secure the SDN12 enclosure, protecting against unauthorized entry while the MCCB is in the ON position. Use them on enclosures with right side flanges only and material thickness from 16 gauge through 3/16”. All mounting hardware is included for enclosures up to 40” tall. The addition of the C361KR roller kit is necessary for enclosures taller than 40” that require a 3-point latch. See SDN12 Enclosures section for enclosure specifications Safety Door Hardware Selection Guide Price C361KJ4 $232.00 C361KJ6 $243.75 C361KR $52.50 Test Equipment Clip for mounting G-Frame to 35 mm Din rail. Mounting hardware included. Pkg of 1 NEMA 12 Safety Door Hardware Part Number Tools Description Enclosures Enclosure Climate Control Safety: Electrical Components Safety: Protective Wear Handle in OFF position Terms and Conditions Description Handle length: 4”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed. Handle length: 6”. Mounting hardware included for enclosures up to 40” tall. For taller enclosures that require a 3-point latch, the C361KR (purchase separately) will also be needed. Door Interlocking safety roller kit for use with the C361KJ4 and C361KJ6 safety handle kits when the SDN12 series enclosure is taller than 40 inches and 3-point latching is required. Kit includes roller and all hardware. Note: The 1/4” x 1/2” standard mill rectangular locking bar is not supplied with these kits. The bar is supplied with the enclosures. Release Screw Safety Handle shown on enclosure Book 3 (14.3) w w w. a u t o m a t i o n d i r e c t . c o m / c i r c u i t- p r o t e c t i o n Circuit Protection eCP-55