Baying systems TS 8 Height: 1200, depth: 500/height: 1400, depth: 500 F1 T F1 T B G1 H G1 B H B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Width (B) mm Packs of Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Approvals, see page 30. Detailed drawing/nominal dimensions, see page 1184 – 1185. Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. 600 800 1200 600 800 1200 Height (H) mm 1200 1200 1200 1400 1400 1400 Depth (T) mm 500 500 500 500 500 500 Mounting plate width (F1) mm 499 699 1099 499 699 1099 Mounting plate height (G1) mm Model No. TS 1 1096 1096 1096 1296 1296 1296 8615.500 8815.500 8215.500 8645.500 8845.500 8245.500 Door(s) Weight (kg) 1 1 2 1 1 2 74.5 92.1 140.0 86.0 107.5 163.5 Page Walls Side panels 2 8115.235 8115.235 8115.235 8145.235 8145.235 8145.235 917 Divider panel 1 – – – 8609.450 8609.450 8609.450 921 Height 100 mm 1 set 8601.600 8601.800 8601.200 8601.600 8601.800 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.200 8602.600 8602.800 8602.200 893 Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 8601.050 893 Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 8602.050 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 4191.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 4944.000 4945.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4596.000 4596.000 4598.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 4116.000 4118.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Signal pillar LED compact, Model No. see page 1125. Baying cover, top, Model No. see page 932. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 138 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 1600, depth: 500 F1 F1 T B B G1 H G1 T H B Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Width (B) mm Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Approvals, see page 30. Detailed drawing/nominal dimensions, see page 1184 – 1185. Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Packs of 600 800 1200 Height (H) mm 1600 1600 1600 Depth (T) mm 500 500 500 Mounting plate width (F1) mm 499 699 1099 Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) Baying systems TS 8 1.3 1496 1496 1496 8665.500 8865.500 8265.500 1 1 2 100.0 103.0 159.3 Page Walls Side panels 2 8165.235 8165.235 8165.235 917 Divider panel 1 8609.650 8609.650 8609.650 921 Height 100 mm 1 set 8601.600 8601.800 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.200 893 Height 100 mm 1 set 8601.050 8601.050 8601.050 893 Height 200 mm 1 set 8602.050 8602.050 8602.050 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Connector gland for connecting a keyboard, mouse or scanner, Model No. see page 1057. Hinge attachment for partial mounting plates, Model No. see page 985. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Rittal Catalogue 32/Industrial Enclosures 139 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 1800, depth: 400 F1 T F1 T B G1 H G1 B H B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Width (B) mm Packs of Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Accessories: Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 600 800 1000 1000 1200 Height (H) mm 1800 1800 1800 1800 1800 Depth (T) mm 400 400 400 400 400 Mounting plate width (F1) mm 499 699 899 899 1099 Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) 1696 1696 1696 1696 1696 8684.500 8884.500 8084.500 8080.500 8284.500 1 1 1 2 2 91.3 113.5 136.4 140.0 170.6 Page Walls Side panels 2 8184.235 8184.235 8184.235 8184.235 8184.235 917 Divider panel 1 8609.840 8609.840 8609.840 8609.840 8609.840 921 Height 100 mm 1 set 8601.600 8601.800 8601.000 8601.000 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.000 8602.000 8602.200 893 Height 100 mm 1 set 8601.040 8601.040 8601.040 8601.040 8601.040 893 Height 200 mm 1 set 8602.040 8602.040 8602.040 8602.040 8602.040 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4336.000 4336.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4946.000 4946.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4599.000 4309.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4124.000 4115.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Snap-on nut for screw-fastening to the vertical section, Model No. see page 1005. System window to protect against unauthorised access and preserve the protection category, Model No. see page 943. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Ppage 632 140 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 1800, depth: 500 F1 T F1 T B G1 H G1 B H B Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8485.510). Width (B) mm Packs of Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Accessories: Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 400 600 800 800 1200 Height (H) mm 1800 1800 1800 1800 1800 Depth (T) mm 500 500 500 500 500 – 499 699 699 1099 Mounting plate width (F1) mm Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) Baying systems TS 8 1.3 – 1696 1696 1696 1696 8485.5101) 8685.500 8885.500 8880.500 8285.500 1 1 1 2 2 49.2 93.8 115.8 122.5 173.3 Page Walls Side panels 2 8185.235 8185.235 8185.235 8185.235 8185.235 Divider panel 1 8609.850 8609.850 8609.850 8609.850 8609.850 917 921 Divider panel for module plates 1 8609.100 8609.100 8609.100 8609.100 8609.100 922 Height 100 mm 1 set 8601.400 8601.600 8601.800 8601.800 8601.200 893 Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.800 8602.200 893 Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 893 Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 893 Cable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4945.000 4947.000 999 Support strips for door 20 – 4596.000 4598.000 4594.000 4596.000 964 Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4114.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. 1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810. Delivery times available on request. Interface flap for safe, modular accommodation of sockets and interfaces, Model No. see page 1151. Compact light for space-saving installation on a vertical or horizontal section, Model No. see page 1027. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 Rittal Catalogue 32/Industrial Enclosures 141 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 1800, depth: 600 F1 T F1 T B G1 H G1 B H B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8486.510). Mounting plates and gland plates: Zinc-plated Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel, roof plate and 2 support strips (TS 4696.000, see page 997), fitted in the enclosure depth. Width (B) mm Packs of Accessories: Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 400 600 800 800 1200 Height (H) mm 1800 1800 1800 1800 1800 Depth (T) mm 600 600 600 600 600 – 499 699 699 1099 Mounting plate width (F1) mm Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) – 1696 1696 1696 1696 8486.5101) 8686.500 8886.500 8881.500 8286.500 1 1 1 2 2 51.7 96.8 120.3 125.8 179.9 Page Walls Side panels 2 8186.235 8186.235 8186.235 8186.235 8186.235 Divider panel 1 8609.860 8609.860 8609.860 8609.860 8609.860 917 921 Divider panel for module plates 1 8609.110 8609.110 8609.110 8609.110 8609.110 922 Climate control side panel 1 3331.XXX 3331.XXX 3331.XXX 3331.XXX 3331.XXX 635 Height 100 mm 1 set 8601.400 8601.600 8601.800 8601.800 8601.200 893 Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.800 8602.200 893 Height 100 mm 1 set 8601.060 8601.060 8601.060 8601.060 8601.060 893 Height 200 mm 1 set 8602.060 8602.060 8602.060 8602.060 8602.060 893 Cable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4945.000 4947.000 999 Support strips for door 20 – 4596.000 4598.000 4594.000 4596.000 964 Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4114.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. 1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 913. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810. Delivery times available on request. TFT monitor for installation in doors and side panels, Model No. see page 1133. Gland plates, Model No. see from page 911. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 142 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 2000, depth: 400 F1 T F1 T B G1 H G1 B H B Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Accessories: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Width (B) mm Possible alternative: 600 800 1000 1200 Height (H) mm Packs of 2000 2000 2000 2000 Depth (T) mm 400 400 400 400 Mounting plate width (F1) mm 499 699 899 1099 Mounting plate height (G1) mm Model No. TS Baying systems TS 8 1.3 1 Door(s) Weight (kg) 1896 1896 1896 1896 8604.500 8804.500 8004.500 8204.500 1 1 2 2 99.0 124.0 152.8 184.5 Page Walls Side panels 2 8104.235 8104.235 8104.235 8104.235 917 Divider panel 1 8609.040 8609.040 8609.040 8609.040 921 Height 100 mm 1 set 8601.600 8601.800 8601.000 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.000 8602.200 893 Height 100 mm 1 set 8601.040 8601.040 8601.040 8601.040 893 Height 200 mm 1 set 8602.040 8602.040 8602.040 8602.040 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4336.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4946.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4309.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4115.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Cable trunking, vertical, to match the section and horizontally to match the mounting plate, Model No. see page 1059 – 1060. Rail for EMC shielding brackets and cable clamps, Model No. see page 1031. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 Rittal Catalogue 32/Industrial Enclosures 143 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 2000, depth: 500 F1 T F1 T B G1 H G1 B H B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plate and gland plates: Zinc-plated Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8405.510). Width (B) mm Packs of Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Accessories: Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 400 600 800 1000 1200 Height (H) mm 2000 2000 2000 2000 2000 Depth (T) mm 500 500 500 500 500 – 499 699 899 1099 Mounting plate width (F1) mm Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) – 1896 1896 1896 1896 8405.5101) 8605.500 8805.500 8005.500 8205.500 1 1 1 2 2 60.7 101.3 126.3 157.1 190.6 Page Walls Side panels 2 8105.235 8105.235 8105.235 8105.235 8105.235 Divider panel 1 8609.050 8609.050 8609.050 8609.050 8609.050 917 921 Divider panel for module plates 1 8609.120 8609.120 8609.120 8609.120 8609.120 922 Height 100 mm 1 set 8601.400 8601.600 8601.800 8601.000 8601.200 893 Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.000 8602.200 893 Height 100 mm 1 set 8601.050 8601.050 8601.050 8601.050 8601.050 893 Height 200 mm 1 set 8602.050 8602.050 8602.050 8602.050 8602.050 893 Cable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4336.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4946.000 4947.000 999 Support strips for door 20 – 4596.000 4598.000 4309.000 4596.000 964 Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4115.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956 and comfort handle, see page 947 – 948. 1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810. Delivery times available on request. Cable glands of polyamide or brass, Model No. see page 1054. Keyboard, pull-out with integral trackball, Model No. see page 1137. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 144 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 2000, depth: 600 F1 T F1 T B G1 H G1 B H B Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12 (except TS 8406.510). Mounting plates and gland plates: Zinc-plated Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel, roof plate and 2 support strips (TS 4696.000, see page 997), fitted in the enclosure depth. Width (B) mm Packs of Accessories: Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 400 600 800 1000 1200 Height (H) mm 2000 2000 2000 2000 2000 Depth (T) mm 600 600 600 600 600 – 499 699 899 1099 Mounting plate width (F1) mm Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) Baying systems TS 8 1.3 – 1896 1896 1896 1896 8406.5101) 8606.500 8806.500 8006.500 8206.500 1 1 1 2 2 55.7 104.0 130.5 161.2 194.6 Page Walls Side panels 2 8106.235 8106.235 8106.235 8106.235 8106.235 Divider panel 1 8609.060 8609.060 8609.060 8609.060 8609.060 917 921 Divider panel for module plates 1 8609.130 8609.130 8609.130 8609.130 8609.130 922 Climate control side panel 1 3331.XXX 3331.XXX 3331.XXX 3331.XXX 3331.XXX 635 Height 100 mm 1 set 8601.400 8601.600 8601.800 8601.000 8601.200 893 Height 200 mm 1 set 8602.400 8602.600 8602.800 8602.000 8602.200 893 Height 100 mm 1 set 8601.060 8601.060 8601.060 8601.060 8601.060 893 Height 200 mm 1 set 8602.060 8602.060 8602.060 8602.060 8602.060 893 Cable clamp rails for cable clamps 2 4193.000 4191.000 4192.000 4336.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 – 4944.000 4945.000 4946.000 4947.000 999 Support strips for door 20 – 4596.000 4598.000 4309.000 4596.000 964 Wiring plan pocket, sheet steel 1 – 4116.000 4118.000 4115.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. 1) Without tubular door frame, mounting plate and gland plates. Available to order as accessories: Mounting plate, see page 987, gland plates, see from page 911. To order enclosures in textured RAL 7032 please add extension .600 or .610 to the Model No., and for primed enclosures use extension .800 or .810. Delivery times available on request. Section for cable entry for top mounting on gland plates with routing of the cable clamp strip, Model No. see page 1046. Module plate for cable entry in the divider panel, Model No. see page 923 – 924. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 Rittal Catalogue 32/Industrial Enclosures 145 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 2000, depth: 800 F1 T F1 T B G1 H G1 B H B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Width (B) mm Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Possible alternative: Instead of a door or rear panel, matching section doors with integral cooling module, see page 633 – 634. Accessories: Approvals, see page 30. Corner enclosures, see page 933. Detailed drawing/nominal dimensions, see page 1184 – 1185. 600 800 1200 Height (H) mm Packs of 2000 2000 2000 Depth (T) mm 800 800 800 Mounting plate width (F1) mm 499 699 1099 Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) Page 1896 1896 1896 8608.500 8808.500 8208.500 1 1 2 111.3 137.0 203.0 Walls Side panels 2 8108.235 8108.235 8108.235 Divider panel 1 8609.080 8609.080 8609.080 917 921 TS 8 internal fan mounting panel 1 3348.200 3348.200 3348.200 707 Height 100 mm 1 set 8601.600 8601.800 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.200 893 Height 100 mm 1 set 8601.080 8601.080 8601.080 893 Height 200 mm 1 set 8602.080 8602.080 8602.080 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Punched section without mounting flange 45 x 88 mm The universal configuration solution with 11 rows of holes for heavy equipment and screwfastening to the frame, Model No. see page 995. Mounting plate attachment in conjunction with mounting plate infill, Model No. see page 979. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 146 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Height: 2200, depth: 600 F1 F1 T B B G1 H G1 T H B Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Width (B) mm Protection category: IP 55 to EN 60 529/09.2000, complies with NEMA 12. Accessories: Corner enclosures, see page 933. Supply includes: Enclosure frame with doors, mounting plate, gland plates, rear panel and roof plate. Packs of Approvals, see page 30. Detailed drawing/nominal dimensions, see page 1184 – 1185. 600 800 1200 Height (H) mm 2200 2200 2200 Depth (T) mm 600 600 600 Mounting plate width (F1) mm 499 699 1099 Mounting plate height (G1) mm Model No. TS 1 Door(s) Weight (kg) Baying systems TS 8 1.3 2096 2096 2096 8626.500 8826.500 8226.500 1 1 2 113.1 139.3 208.0 Page Walls Side panels 2 8126.235 8126.235 8126.235 917 Divider panel 1 8609.260 8609.260 8609.260 921 Height 100 mm 1 set 8601.600 8601.800 8601.200 893 Height 200 mm 1 set 8602.600 8602.800 8602.200 893 Height 100 mm 1 set 8601.060 8601.060 8601.060 893 Height 200 mm 1 set 8602.060 8602.060 8602.060 893 Cable clamp rails for cable clamps 2 4191.000 4192.000 4196.000 1061 Cable clamp rails (C section) for cable clamps 6 4944.000 4945.000 4947.000 999 Support strips for door 20 4596.000 4598.000 4596.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 967 Base/plinth Components front and rear Trim panels (sides) Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in textured RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Gland plate with sealing bar for sub-dividing the base assembly for varying cable entry, Model No. see page 912. Module plate with cable sleeves for cable diameters 10 – 65 mm, Model No. see page 924. Accessories Page 890 TS 8 stainless steel Page 322 TS 8 EMC-shielded Page 329 Modular climate control concept Page 632 Rittal Catalogue 32/Industrial Enclosures 147 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Electronic enclosure T B H Z 48 4 4 46 50 5 Z B Baying systems TS 8 1.3 Material: Enclosure frame: Sheet steel, 1.5 mm Front frame: Extruded aluminium sections with die-cast corner pieces Rear door: 2 mm sheet steel Roof and gland plates: 1.5 mm sheet steel Adaptor sections: Aluminium Surface finish: Enclosure frame: Dipcoat-primed Front frame, rear door and roof: Powder-coated in RAL 7035 Gland plates: Zinc-plated U Packs of Supply includes: Enclosure frame, front frame (r/h hinge, opening angle 130°, held via mechanical snap fasteners on left), rear door (r/h hinge, may be swapped to opposite side), roof, adaptor sections and gland plates. Approvals, see page 31. Detailed drawing/nominal dimensions, see page 1186. 33 33 42 42 Width (B) mm 600 600 600 600 Height (H) mm 1600 1600 2000 2000 Depth (T) mm 600 800 600 800 8410.510 8418.510 8430.510 8438.510 1 1 1 1 Model No. TS 1 Door(s) Page Base/plinth Height 100 mm 1 set 8601.600 8601.600 8601.600 8601.600 893 Height 200 mm 1 set 8602.600 8602.600 8602.600 8602.600 893 Height 100 mm 1 set 8601.060 8601.080 8601.060 8601.080 893 Height 200 mm 1 set 8602.060 8602.080 8602.060 8602.080 893 Side panels 2 8166.235 8168.235 8106.235 8108.235 917 Cable clamp rails for cable clamps 2 4191.000 4191.000 4191.000 4191.000 1061 Components front and rear Trim panels (sides) Accessories Cable clamp rails (C section) for cable clamps 6 4944.000 4944.000 4944.000 4944.000 999 Adaptor sections for rear 2 8613.360 8613.360 8613.300 8613.300 1090 Lock systems Standard double-bit lock insert (in rear door) may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. For primed enclosures, please add extension .810 to the Model No. Delivery times available on request. Slide rails, Model No. see page 1097. Aluminium cross rail, for sub-division of the front, Model No. see page 1090. Accessories Page 890 482.6 mm (19″) mounting accessories From page 1079 Subrack systems Page 548 482.6 mm (19″) climate control Page 698 – 700 148 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 For modular front design T H B B The basic enclosures without ● Mounting plate for universal interior installation with − Partial mounting plates − Component shelves and drawers − Punched sections and rails ● Doors Frame for the installation of − Partial doors with and without viewing panels − Fully glazed doors − Drawers and desk sections − Profile blanking frame − Vertically divided doors − Trim panels hinged at the top Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Supply includes: Enclosure frame, roof, rear panel, gland plates, three-piece. Detailed drawing (TS basic enclosures without door), see page 1186. Baying systems TS 8 1.3 Surface finish: Enclosure frame: Dipcoat-primed Door and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Gland plates: Zinc-plated Width (B) mm Packs of Height (H) mm Depth (T) mm Model No. TS 1 Weight (kg) 600 800 2000 2000 600 600 8606.512 8806.512 52.5 63.0 Page Walls Side panels 2 8106.512 8106.512 942 Divider panel 1 8609.060 8609.060 921 Divider panel for module plates 1 8609.130 8609.130 922 Height 100 mm 1 set 8601.600 8601.800 893 Height 200 mm 1 set 8602.600 8602.800 893 Height 100 mm 1 set 8601.060 8601.060 893 Height 200 mm 1 set 8602.060 8602.060 893 Base/plinth Components front and rear Trim panels (sides) To order enclosures in textured RAL 7032 please add extension .612 to the Model No., and for primed enclosures use extension .812. Delivery times available on request. Trim panels TS For height trim at the top and bottom, Model No. see page 941. Protective bar and holder, Model No. see page 938. Accessories Page 890 Partial doors Page 941 Partial mounting plates Page 984 Rittal Catalogue 32/Industrial Enclosures 149 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 For isolator door locking F T B H G B2 B Baying systems TS 8 1.3 Material: Sheet steel Enclosure frame, roof, rear panel and gland plates: 1.5 mm Door and trim panel: 2.0 mm Mounting plate: 3.0 mm Surface finish: Enclosure frame: Dipcoat-primed Door, trim panel, roof and rear panel: Dipcoat-primed, powder-coated in textured RAL 7035 on the outside Mounting plates and gland plates: Zinc-plated Width (B) mm Packs of Height (H) mm Protection category: IP 55 to EN 60 529/09.2000 Complies with NEMA 12 (with fitted/sealed isolator switch actuation) Rittal service: Enclosures with 100 mm (instead of 200 mm) wide trim panel on request. Supply includes: Enclosure frame, door (l/h hinge), trim panel (r/h hinge, with a swing lever at the top and bottom, with cut-out for isolator switch actuation), roof, rear panel, mounting plate, threepiece gland plates. Approvals, see page 31. Detailed drawing/nominal dimensions, see page 1187. 800 800 800 800 1800 1800 2000 2000 Depth (T) mm 400 500 500 600 Mounting plate width (F) mm 699 699 699 699 Mounting plate height (G) mm Model No. TS 1 Door(s) Weight (kg) 1696 1696 1896 1896 8984.500 8985.500 8905.500 8906.500 1 1 1 1 113.5 115.8 126.3 130.5 Page Base/plinth Components front and rear Trim panels (sides) Height 100 mm 1 set 8601.800 8601.800 8601.800 8601.800 893 Height 200 mm 1 set 8602.800 8602.800 8602.800 8602.800 893 Height 100 mm 1 set 8601.040 8601.050 8601.050 8601.060 893 Height 200 mm 1 set 8602.040 8602.050 8602.050 8602.060 893 Also required Door latch for bayed suites 960 Accessories Isolator door locking (USA version) 1 8611.310 8611.310 8611.310 8611.310 960 Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. To order enclosures in RAL 7032 please add extension .600 to the Model No., and for primed enclosures use extension .800. Delivery times available on request. Cable gland Cable glands made from polyamide or brass, Model No. see page 1054. Snap-on nut for screw-fastening to the vertical section, Model No. see page 1005. Accessories Page 890 Adjacent door locking Page 951 150 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 IP 66/NEMA 4x, NEMA 4 F T H G B B Material: NEMA 4x: Stainless steel 1.4301 (AISI 304) NEMA 4: Sheet steel, spray-finished Enclosure frame, roof, base/ plinth, rear panel, side panels: 1.5 mm Door: 2.0 mm Mounting plate: 3.0 mm (sheet steel) Surface finish: NEMA 4x: Enclosure frame: Uncoated Door, roof, base, rear panel, side panels: Brushed on the outside, grain size 400 Mounting plate: Zinc-plated Protection category: IP 66 to EN 60 529/09.2000 (complies with NEMA 4x/ NEMA 4) NEMA 4: Enclosure frame, door, roof, base, rear panel, side panels: Dipcoat-primed and powder-coated in textured RAL 7035 on the outside Mounting plate: Zinc-plated Supply includes: NEMA 4x/NEMA 4: Enclosure frame with door, roof/base plate, rear panel, side panels, mounting plate. NEMA 4x, stainless steel Packs of Rittal service: Enclosures with depth 800 mm on request. Approvals, see page 31. NEMA 4, sheet steel Page Width (B) mm 600 800 600 800 600 800 600 800 Height (H) mm 1800 1800 2000 2000 1800 1800 2000 2000 Depth (T) mm 600 600 600 600 600 600 600 600 Mounting plate width (F) mm 499 699 499 699 499 699 499 699 Mounting plate height (G) mm 1696 1696 1896 1896 1696 1696 1896 1896 8458.640 8459.640 8452.640 8450.640 8686.540 8886.540 8606.540 8806.540 1 1 1 1 1 1 1 1 Model No. TS 1 Door(s) Baying systems TS 8 1.3 Base/plinth Height 100 mm 1 set 8701.600 8701.800 8701.600 8701.800 8601.600 8601.800 8601.600 8601.800 893, 899 Height 200 mm 1 set 8702.600 8702.800 8702.600 8702.800 8602.600 8602.800 8602.600 8602.800 893, 899 Height 100 mm 1 set 8701.060 8701.060 8701.060 8701.060 8601.060 8601.060 8601.060 8601.060 893, 899 Height 200 mm 1 set 8702.060 8702.060 8702.060 8702.060 8602.060 8602.060 8602.060 8602.060 893, 899 4 2913.000 2913.000 2913.000 2913.000 – – – – 899 Cable clamp rails 2 4191.000 4192.000 4191.000 4192.000 4191.000 4192.000 4191.000 4192.000 1061 System support rails 2 4361.000 4362.000 4361.000 4362.000 4361.000 4362.000 4361.000 4362.000 1000 Support strips for door 20 4596.000 4598.000 4596.000 4598.000 4596.000 4598.000 4596.000 4598.000 964 Wiring plan pocket, sheet steel 1 4116.000 4118.000 4116.000 4118.000 4116.000 4118.000 4116.000 4118.000 967 Components front and rear Trim panels (sides) Base/plinth trim, modular SO Accessories Lock systems Standard double-bit lock insert may be exchanged for lock inserts, type F, see page 956, and comfort handle, see page 947 – 948. Delivery times available on request. Cable glands IP 68 Cable glands made from polyamide or brass, Model No. see page 1054. Punched rail 25 x 38 mm, Model No. see page 996. Accessories Page 890 Cable entry From page 1045 Rittal Catalogue 32/Industrial Enclosures 151 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 Prepared for EX pressurisation F T H G B B Baying systems TS 8 1.3 With this empty enclosure and an external overpressure controller such as those offered by STAHL, Bartec or Gönnheimer, conventional operating materials may be used in explosion hazard areas. To this end, a permanent overpressure is applied to the enclosure which prevents the ingress of potentially explosive atmospheres. Empty enclosure, prepared for pressurisation, ensures efficient operation thanks to low leakage rates of approximately 20 l/min, at 2 mbar overpressure. Ex overpressure enclosures must be constructed and operated in conformity with standards DIN EN 60 079-0 and DIN EN 60 079-2. For populated enclosures of protection type “p”, in accordance with Directive 94/9 EC, type testing certification from a designated office is required. Design: ● Base as for roof ● Reinforced: − Rear panel − Side panels − Door with additional cams top and bottom, r/h hinge, l/h hinge on request Protection category: IP 55 to EN 60 529/09.2000 complies with NEMA 12 Surface finish: Sheet steel: Enclosure frame: Dipcoatprimed door, roof, base, side panels and rear panel: Dipcoatprimed, powder-coated in textured RAL 7035 on the outside Mounting plate: Zinc-plated Supply includes: Enclosure frame with door (with additional cam top and bottom), roof/base plate, rear panel, side panels, mounting plate. Stainless steel: Enclosure frame: Uncoated Door, side panels, roof, base/ plinth, and rear panel: Brushed, grain size 400 Mounting plate: Zinc-plated Rittal service: Enclosures for baying available on request. Width (B) mm 600 800 600 800 600 800 1000 600 800 600 – Height (H) mm 1400 1400 1600 1600 1800 1800 1800 1800 1800 1800 – Depth (T) mm 500 500 500 500 400 400 400 500 500 600 – Mounting plate width (F) mm 499 699 499 699 499 699 899 499 699 499 – Mounting plate height (G) mm 1296 1296 1496 1496 1696 1696 1696 1696 1696 1696 – 8645.560 8845.560 8665.560 8865.560 8684.560 8884.560 8084.560 8685.560 8885.560 8686.560 – Model No. TS sheet steel Width (B) mm 800 600 800 600 800 600 800 600 800 600 800 Height (H) mm 1800 2000 2000 2000 2000 2000 2000 2000 2000 2200 2200 Depth (T) mm 600 400 400 500 500 600 600 800 800 600 600 Mounting plate width (F) mm 699 499 699 499 699 499 699 499 699 499 699 Mounting plate height (G) mm 1696 1896 1896 1896 1896 1896 1896 1896 1896 2096 2096 8886.560 8604.560 8804.560 8605.560 8805.560 8606.560 8806.560 8608.560 8808.560 8626.560 8826.560 Width (B) mm 800 1000 600 800 600 600 800 800 – – – Height (H) mm 1800 1800 1800 1800 1800 2000 2000 2000 – – – Depth (T) mm 400 400 500 500 600 600 600 800 – – – Mounting plate width (F) mm 699 899 499 699 499 499 699 699 – – – Mounting plate height (G) mm 1696 1696 1696 1696 1696 1896 1896 1896 – – – Model No. TS stainless steel 8454.660 8461.660 8457.660 8455.660 8458.660 8452.660 8450.660 8460.660 – – – Model No. TS sheet steel Delivery times available on request. Accessories Page 890 Cable entry From page 1045 152 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Baying systems TS 8 For areas at risk from earthquakes 2 4 TS 8 for earthquake zone 1, 2 and 3 to Bellcore TS 8806.500: W x H x D 800 x 2000 x 600 mm TS 8 for earthquake zone 4 to Bellcore TS 8806.500: W x H x D 800 x 2000 x 600 mm With base/plinth (base/plinth components front and rear and base/plinth trim, side, see page 893), 100 mm high with a weight load of 125 kg spread evenly over the mounting plate. Fitted with: ● Earthquake kit and ● Earthquake base/plinth, see page 153, Note: These versions have been tested and meet the requirements to Telcordia GR 63-CORE. They should be seen as a comparative variable to the customer’s own plant, since the certification of empty enclosures is not possible. 1 Earthquake kit Material: Sheet steel 3 Surface finish: Zinc-plated, passivated Supply includes: with weight load of 450 kg distributed evenly over the mounting plate. 1.3 Rittal service: ● Mounting on the enclosure on request. For enclosures WxHxD mm Packs of 800 x 2000 x 600 1 8613.860 600 x 2000 x 600 1 8613.6601) 600 x 2000 x 400 1 8613.6401) 1) Delivery B Baying systems TS 8 3 Model No. TS times available on request. 1 2 side reinforcements, bottom 2 2 bracing struts each, sides 3 8 gusset plates 4 Mounting plate attachment and reinforcement 2 including assembly parts 4 Earthquake base/plinth Height 100 mm Material: Sheet steel Corner pieces: 5 mm Trim panels: 2 mm Surface finish: Powder-coated in RAL 7022 For enclosures WxD mm Packs of 800 x 600 1 8601.860 600 x 600 1 8601.6601) 600 x 400 1 8601.6401) 1) Delivery Model No. TS times available on request. Supply includes: 1 set = ● 4 corner pieces ● 2 depth stays ● 1 trim panel each front and rear fully assembled. Accessories Page 890 Base/plinth Page 892 Rittal Catalogue 32/Industrial Enclosures 153 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Enclosures Large enclosures 1.3 Baying system TS 8 Spray-finished Page 138 – 147 Stainless steel Page 322 B1 B7 T7 35 35 55 46 3.5 2.5 C 64.5 i.L. T3 60 2.5 60 B1 B7 30 T6 2 B6 B6 B6 17 H5 G i.L. H3 Ø6 51 Ø9 32.5 25 H9 71 Ø 4.6 Ø9 H1 4 x 25 (= 100) 4 x 25 (= 100) H9 71 i.L. B5 H2 71 i.L. B5 H4 H8 H6 i.L. H7 H4 71 H8 H6 i.L. H7 i.L. B5 62.5 i.L. T5 44 4.5 22 M6 96 22 96 M6 T4 T1 18 i.L. T3 78.5 i.L. B8 1 Does not apply to 6 30 65 46.5 M12 15 30 65 B2 i.L. B8 Ø1 M12 i.L. B3 46.5 30 65 18 78.5 Note: With fitted side panels, the overall width (B1) is increased by 9 mm. Between bayed enclosures, allow 3 mm for the seal. i.L. B3 B2 Base/plinth mounting: B4 x T2 TS 8880.500/TS 8881.500 15 i.L. B8 16 49 F 78.5 46.5 Ø 30 1 49 T1 49 F 61 B4 30 T2 T2 49 78.5 61 46.5 30 i.L. T3 30 30 65 61 B4 61 T1 Industrial Enclosures 1. i.L. = Clearance width Base/plinth mounting: B4 x T2 Double-door Model No. TS Width dimensions mm Spray- Stainless B1 finished steel B2 B3 B4 B5 B6 Height dimensions mm B7 B8 H1 H2 H3 H4 H5 H6 H7 Mounting plates mm Depth dimensions mm H8 H9 T1 T2 T3 T4 T5 T6 T7 F G 8215.500 – 1197 1192 1112 1075 455 475 1135 500 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 1099 1096 8245.500 – 1197 1192 1112 1075 455 475 1135 500 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 1099 1296 8080.500 – 997 992 912 875 355 375 935 400 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 899 1696 8284.500 8456.X00 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 1099 1696 8880.500 – 797 792 712 675 255 275 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 699 1696 8285.500 8453.X00 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 1099 1696 8881.500 – 797 792 712 675 255 275 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 699 1696 8286.500 – 1197 1192 1112 1075 455 475 1135 500 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 1099 1696 8004.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 899 1896 8204.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 1099 1896 8005.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 899 1896 8205.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 1099 1896 8006.500 – 997 992 912 875 355 375 935 400 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 899 1896 8206.500 8451.X00 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 1099 1896 8208.500 – 1197 1192 1112 1075 455 475 1135 500 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 1099 1896 8226.500 – 1197 1192 1112 1075 455 475 1135 500 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 1099 2096 8265.500 – 1197 1192 1112 1075 455 475 1135 500 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 1099 1496 1184 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Enclosures Large enclosures Enclosure Cross-sections vertical F B1 = B2 = B3 = B4 = 23 25 4.5 48 24.5 42.5 12.5 42 73 25 12.5 24.5 i.L. (T3) 42.5 6.5 23 17 23 B5 = B6 = i.L. (B3) B7 = B8 = 4 H1 = Overall height H2 = Height of rear panel H3 = Clearance between the enclosure frame H4 = Height of door H5 = Section length of system punchings H6 = Distance between axes of tubular door frame holes H7 = Clearance between the tubular door frame H8 = Distance between the fastening bolts of the tubular door frame H9 = Distance from base to centre of lock horizontal G 11.5 20 25 4 10.5 12.5 12.5 42.5 42.5 12.5 i.L. (H3) 4.5 i.L. (B3/T3) Overall width Width of door Clearance between the enclosure frames Section length of system punchings/ hole spacing base/plinth attachment Clearance between the tubular door frames Distance between axes of tubular door frame holes Distance between the lifting eyes Clearance in the base opening C 1. Industrial Enclosures Mounting plate T1 = Overall depth T2 = Section length of system punchings/ hole spacing T3 = Clearance between the enclosure frames T4 = Depth of base frame T5 = Clearance of base opening T6 = Possible mounting depth (mounting plate assembly) depth-adjustable on a 25 mm pitch pattern T7 = Centre of lifting eye to centre of lifting eye i.L. = Clearance width Mounting plate F = Overall width G = Overall height Single-door Model No. TS Width dimensions mm Spray- Stainless B1 finished steel B2 B3 B4 B5 B6 Height dimensions mm B7 B8 H1 H2 H3 H4 H5 H6 H7 Mounting plates mm Depth dimensions mm H8 H9 T1 T2 T3 T4 T5 T6 T7 F G 8615.500 – 597 592 512 475 455 475 535 440 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 499 1096 8815.500 – 797 792 712 675 655 675 735 640 1205 1197 1112 1177.5 1075 1050 1030 1000 611 505 375 412 468 340 130 – 455 435 699 1096 8645.500 – 597 592 512 475 455 475 535 440 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 499 1296 8845.500 – 797 792 712 675 655 675 735 640 1405 1397 1312 1377.5 1275 1250 1230 1200 711 505 375 412 468 340 130 – 455 435 499 1296 8684.500 – 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 499 1696 8884.500 8454.X00 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 699 1696 8084.500 – 997 992 912 875 855 875 935 840 1805 1797 1712 1777.5 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 899 1696 8485.510 – 397 392 312 275 255 275 335 240 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 – – 8685.500 8457.X00 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 499 1696 8885.500 8455.X00 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 699 1696 8486.510 – 397 392 312 275 255 275 335 240 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 8686.500 – 597 592 512 475 455 475 535 440 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 499 1696 8886.500 – 797 792 712 675 655 675 735 640 1805 1797 1712 1777.5 1675 1650 1630 1600 911 605 475 512 568 440 130 – 555 535 699 1696 8604.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 499 1896 8804.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 405 275 312 368 240 130 – 355 335 699 1896 8405.510 – 397 392 312 275 255 275 335 240 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 8605.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 499 1896 8805.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 699 1896 8406.510 – 397 392 312 275 255 275 335 240 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 – – – – – – 8606.500 8452.X00 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 499 1896 8806.500 8450.X00 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 699 1896 8608.500 – 597 592 512 475 455 475 535 440 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 499 1896 8808.500 – 797 792 712 675 655 675 735 640 2005 1997 1912 1977.5 1875 1850 1830 1800 1011 805 675 712 768 640 130 – 755 735 699 1896 8626.500 – 597 592 512 475 455 475 535 440 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 499 2096 8826.500 – 797 792 712 675 655 675 735 640 2205 2197 2112 2177.5 2075 2050 2030 2000 1111 605 475 512 568 440 130 – 555 535 699 2096 8665.500 – 597 592 512 475 455 475 535 440 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 499 1496 8865.500 – 797 792 712 675 655 675 735 640 1605 1597 1512 1577.5 1475 1450 1430 1400 811 505 375 412 468 340 130 – 455 435 699 1496 Rittal Catalogue 32/Industrial Enclosures 1185 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Enclosures Large enclosures 1.3 Baying system TS 8 Electronic enclosures Page 148 465 535/735 1466.6 (33 HE)/1866.9 (42 HE) 1512/1912 1605/2005 43 63 452 53 486 HE = U 592 622/822 512/712 512 592 1.3 Baying system TS 8 Cross-sections For modular front design Page 149 vertical i.L. 25 42.5 42.5 25 12.5 4.5 12.5 i.L. 512 475 601.5 i.L. 30 30 65 30 6.5 61 42.5 12.5 77 46 3.5 475/675 46.5 61 i.L. 512 535/735 horizontal 31 4 11.5 Ø1 6 20 4.5 4 10.5 12.5 i.L. 12.5 42.5 i.L. 1850 i.L. = Clearance width i.L. 440 77 44 4.5 25 1997 i.L. 1912 2005 25 597/797 42.5 512/712 42.5 30 65 M12 12.5 535 18 35 597/797 60 Industrial Enclosures 1. 9.5 C 31.75 44.45 7.6 452 568 601.5 1186 Rittal Catalogue 32/Industrial Enclosures Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com Industrial Enclosures Large enclosures 1.3 Baying system TS 8 For isolator door locking Page 150 35 797 Detail X 35 T7 i.L. T3 77 3.5 46 2.5 60 735 Industrial Enclosures 12.7 H5 i.L. H3 H1 H2 H4 i.L. 455 1. 119.1 17 71 H8 H6 475 25.4 22.2 25.4 2 T6 X i.L. H7 C 14.3 12.5 55 340.5 90.5 42.5 7.1 93 H9 4 x 25 (= 100) 1 4.5 22 96 M6 44 51 Ø9 35.5 25 Ø 4.6 1 Only for TS 8906.500 i.L. T5 T4 T1 49 i.L. 640 78.5 18 i.L. T3 T2 699 78.5 Ø1 i.L. = Clearance width 46.5 30 65 30 30 49 T1 61 675 61 6 i.L. 712 592 192 15 46.5 30 65 M12 Enclosure H1 = Overall height H2 = Height of rear panel H3 = Clearance between the enclosure frame H4 = Height of door and trim panel H5 = Section length of system punchings H6 = Distance between axes of the tubular door frame rows of holes H7 = Clearance between the tubular door frame H8 = Distance between the fastening bolts of the tubular door frame H9 = Distance from base to centre of lock Model No. TS Note: The cut-outs in the right-hand trim piece are suitable for the following isolator actuators: Allen Bradley 1494 V-H11, Square D9422A1, ITE Siemens1) Max-Flex series/F HOH, General Electric TDA Type 1 and 2, Moeller NZM-XSHGVR12-NA. T1 = Overall depth T2 = Section length of system punchings/ distance between holes of base/ plinth attachment T3 = Clearance between enclosure frames T4 = Depth of base frame T5 = Clearance of base opening T6 = Possible mounting depth (mounting plate assembly) T7 = Centre of lifting eye to centre of lifting eye 1) Height dimensions mm Available in USA only. Depth dimensions mm H1 H2 H3 H4 H5 H6 H7 H8 H9 T1 T2 T3 T4 T5 T6 T7 8984.500 1805 1797 1712 1754 1675 1650 1630 1600 911 405 275 312 368 240 130 – 355 335 8985.500 1805 1797 1712 1775 1675 1650 1630 1600 911 505 375 412 468 340 130 – 455 435 8905.500 2005 1997 1912 1975 1875 1850 1830 1800 1011 505 375 412 468 340 130 – 455 435 8906.500 2005 1997 1912 1975 1875 1850 1830 1800 1011 605 475 512 568 440 130 – 555 535 Rittal Catalogue 32/Industrial Enclosures 1187 Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com