MODEL QTRE080R Page 1 ULTRA SILENT TM VENTILATION FAN READ AND SAVE THESE INSTRUCTIONS WARNING CLEANING & MAINTENANCE TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: 1. Usethisunitonlyinthemannerintendedbythemanufacturer. Ifyouhavequestions,contactthemanufacturerattheaddress ortelephonenumberlistedinthewarranty. 2. Beforeservicingorcleaningunit,switchpoweroffatservice panel and lock the service disconnecting means to prevent powerfrombeingswitchedonaccidentally.Whentheservice disconnecting means cannot be locked, securely fasten a prominentwarningdevice,suchasatag,totheservicepanel. 3. Installation work and electrical wiring must be done by a qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction codes and standards. 4. Sufficientairisneededforpropercombustionandexhausting of gases through the flue (chimney) of fuel burning equipment to prevent backdrafting. Follow the heating equipment manufacturer’sguidelineandsafetystandardssuchasthose publishedbytheNationalFireProtectionAssociation(NFPA), andtheAmericanSocietyforHeating,RefrigerationandAir ConditioningEngineers(ASHRAE),andthelocalcodeauthorities. 5. When cutting or drilling into wall or ceiling, do not damage electricalwiringandotherhiddenutilities. 6. Ductedfansmustalwaysbeventedtotheoutdoors. 7. Acceptableforuseoveratuborshowerwhenconnectedto aGFCI(GroundFaultCircuitInterrupter)-protectedbranch circuit(ceilinginstallationonly). 8. Thisunitmustbegrounded. Forquietandefficientoperation,longlife,andattractiveappearance-lowerorremovegrilleandvacuuminteriorofunitwiththe dustingbrushattachment. CAUTION 1. Forgeneralventilatinguseonly.Donotusetoexhausthazardousorexplosivematerialsandvapors. 2. Toavoidmotorbearingdamageandnoisyand/orunbalanced impellers,keepdrywallspray,constructiondust,etc.offpower unit. 3. Pleasereadspecificationlabelonproductforfurtherinformationandrequirements. To register this product visit: www.broan.com Themotorispermanentlylubricatedandneverneedsoiling.Ifthe motorbearingsaremakingexcessiveorunusualnoises,replace themotorwiththeexactservicemotor.Theimpellershouldalso bereplaced. OPERATION Useanon/offswitchorspeedcontroltooperatethisventilator.See “ConnectWiring”fordetails.Useofspeedcontrolsotherthanthe BroanModels78Vand78Wmaycauseamotorhummingnoise. WARRANTY BROAN THREE YEAR LIMITED WARRANTY Broanwarrantstotheoriginalconsumerpurchaserofitsproductsthatsuch productswillbefreefromdefectsinmaterialsorworkmanshipforaperiod ofthreeyearsfromthedateoforiginalpurchase.THEREARENOOTHER WARRANTIES,EXPRESSORIMPLIED,INCLUDING,BUTNOTLIMITED TO,IMPLIEDWARRANTIESOFMERCHANTABILITYORFITNESSFOR APARTICULARPURPOSE. Duringthisthree-yearperiod,Broanwill,atitsoption,repairorreplace, withoutcharge,anyproductorpartwhichisfoundtobedefectiveunder normaluseandservice. THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERSANDTUBES.Thiswarrantydoesnotcover(a)normalmaintenanceandserviceor(b)anyproductsorpartswhichhavebeensubject to misuse, negligence, accident, improper maintenance or repair (other thanbyBroan),faultyinstallationorinstallationcontrarytorecommended installationinstructions. Thedurationofanimpliedwarrantyislimitedtothethree-yearperiodas specified for the express warranty. Some states do not allow limitation onhowlonganimpliedwarrantylasts,sotheabove limitation maynot applytoyou. BROAN’S OBLIGATIONTO REPAIR OR REPLACE,AT BROAN’S OPTION,SHALLBETHEPURCHASER’SSOLEANDEXCLUSIVEREMEDY UNDERTHISWARRANTY.BROANSHALLNOTBELIABLEFORINCIDENTAL,CONSEQUENTIALORSPECIALDAMAGESARISINGOUTOF ORINCONNECTIONWITHPRODUCTUSEORPERFORMANCE.Some statesdonotallowtheexclusionorlimitationofincidentalorconsequential damages,sotheabovelimitationmaynotapplytoyou. Thiswarrantygivesyouspecificlegalrights,andyoumayalsohaveother rights,whichvaryfromstatetostate.Thiswarrantysupersedesallprior warranties. Toqualifyforwarrantyservice,youmust(a)notifyBroanattheaddress ortelephonenumberstatedbelow,(b)givethemodelnumberandpart identificationand(c)describethenatureofanydefectintheproductor part.Atthetimeofrequestingwarrantyservice,youmustpresentevidence oftheoriginalpurchasedate. Broan-NuToneLLCHartford,Wisconsin www.broan.com800-558-1711 Installer: Leave this manual with the homeowner. MODEL QTRE080R Page 2 TYPICAL INSTALLATIONS PLAN THE INSTALLATION Amountingframeisprovidedtoallowforaccurate positioningofthefananywhereintheroom.Itcanbe usedwithI-joists,standardjoistsandtrusses,from16”to 24”on-center. Housing mounted anywhere between I-joists using mounting frame. COOKING AREA Do not install above or inside this area. 45o NOT FOR USE IN A COOKING AREA. 45o Cooking Equipment Floor ROOFCAP* Housing mounted anywhere between standard joists using mounting frame. 4-IN.ROUND DUCT* *Purchase separately Housing mounted anywhere between trusses using mounting frame. 4-IN.ROUND ELBOW* WALL CAP* The unit will operate most quietly and efficiently when located wheretheshortestpossibleductrunandminimumnumberof elbowswillbeneeded. Usearoofcaporwallcapthathasabuilt-indampertoreduce backdrafts. Plantosupplytheunitwithproperlinevoltageandappropriate powercable. MODEL QTRE080R Page 3 NEW CONSTRUCTION INSTALLATION INSTALL MOUNTING FRAME & HOUSING TABS FRAMING MEMBER MOUNTING FRAME SCREW ORNAIL(4) SCREW (provided) INSTALL DUCTWORK 4. Connect4”roundductworktoductconnector.Run ductworktoaroofcaporwallcap.Tapeallductwork connections. INSTALL ELECTRICAL WIRING DUCT CONNECTOR DUCTCONNECTOR BRACKET TABS 1. Holdonesideofthemountingframesothetabs touchthebottomedgeoftheframingmember.Nailor screwmountingframeinplace.Extendthemounting frametotheoppositeframingmember,andnailor screwinplace. 2. Snaptheductconnectorontotheductconnector bracket.Attachtheductconnectorbrackettothe mountingframeusingthescrewprovided.Position thebottomedgeoftheductconnectorbracketsoit willbeflushwiththefinishedsurfaceoftheceiling andtightenthescrew. HOUSING SCREW(5) (provided) 3. Positionthetwomovablebracketsofthemounting framedirectlyacrossfromeachotherandinsertthe housingintothemountingframeuntilittouchesthe ductconnectorbracket.Securethehousingtothe mountingframeandductconnectorbracketusingthe (5)screwsprovided.Positionthehousinghorizontally asdesired. 5. Run120VAChousingwiringtoinstallationlocation. UseaULapprovedconnectortosecurehousewiring towiringplate.Connectwiresasshowninwiring diagrams. MODEL QTRE080R Page 4 INSTALL THUMBSCREW & GRILLE THUMBSCREW 6. Installthumbscrewthroughflangeofmotorplateas shown. 7. Installceilingmaterial.Cutoutaroundhousing. 8. Squeezegrillespringsandinsertthemintoslotson eachsideofhousing.Pushgrilleagainstceiling. EXISTING CONSTRUCTION INSTALLATION REMOVE EXISTING FAN WARNING Beforeremovingexistingfan,switchpoweroffatservice panelandlocktheservicedisconnectingmeansto preventpowerfrombeingswitchedonaccidentally.When theservicedisconnectingmeanscannotbelocked, securelyfastenaprominentwarningdevice,suchasa tag,totheservicepanel. 3. Bendthefourtabsbackagainstthesidesofthe mountingframe.Insertthemountingframethrough theceilingopeningandletitrestonthebacksideof theceilingmaterial,directlyovertheceilingopening. Positiononesideofthemountingframesoittouches theframingmember.Nailorscrewmountingframe inplace.Extendthemountingframetotheopposite framingmember,andnailorscrewinplace. CONNECT DUCTWORK EXISTING FAN 12” CEILING FRAMING INSTALL MOUNTING FRAME EXISTING DUCTWORK 11” 1. Enlargetheceilingopeningaroundtheexistingfanto 11”x12”.The11”dimensionshouldrunparalleltothe ceilingframing. 2. Carefullyremovetheexistingfanhousingfromthe ceiling.Disconnecttheductworkandelectricalwiring fromthehousingandleavetheminplaceabovethe ceiling. SCREWOR NAIL(4) FRAMING MEMBER MOUNTING FRAME DUCT CONNECTOR DUCTCONNECTOR BRACKET 4. Snaptheductconnectorontotheductconnector bracket.Retrievetheexistingductworkfromabovethe ceilingandconnectittotheductconnector.Tapethe connection.NOTE:Existingrigidductworkwillrequire ashortlengthof4”flexibleduct.Existing3”ductwork willrequirea3”to4”transition. MODEL QTRE080R Page 5 EXISTING ELECTRICAL WIRING INSTALL HOUSING HOUSING MOUNTING FRAME DUCTCONNECTOR SCREW BRACKET (provided) WIRING PLATE (shown removed fromfan housing) 5. Attachtheductconnectorbrackettothemounting frameusingthe(1)screwprovided.Positionthebottom edgeoftheductconnectorbracketsoittouchesthe finishedsurfaceoftheceilingandtightenthescrew. CONNECT ELECTRICAL WIRING SCREW(5) (provided) 7. Positionthetwomovablebracketsofthemounting framedirectlyacrossfromeachotherandinsertthe housingintothemountingframeuntilittouchesthe ductconnectorbracket.Securethehousingtothe mountingframeandductconnectorbracketusing the(5)screwsprovided. INSTALL THUMBSCREW & GRILLE THUMBSCREW 8. Installthumbscrewthroughflangeofmotorplateas shown. 9. Squeezegrillespringsandinsertthemintoslotson eachsideofhousing.Pushgrilleagainstceiling. 6. Retrievetheexistingelectricalwiringfromabovethe ceilinganduseaULapprovedconnectortosecure ittothewiringplate.Re-attachwiringplatetofan housing,ifnecessary.Connectwiresasshownin wiringdiagrams. MODEL QTRE080R Page 6 SERVICE PARTS Key No. Part No. 1 2 3 4 5 6 7 8 9 10 11 97018118 97016449 98010102 99170245 97018010 97017853 97016497 99140199 98010614 97018138 99420665 Description Housing DuctConnector-4” WiringPlate Screw,#8-18X.375(7Req.) WirePanel/HarnessAssembly BlowerAssembly GrilleAssembly (includeskeyno.8) GrilleSpring(2req’d) DuctConnectorBracket FrameAssembly Thumbscrew,#8-18x.375 Orderservicepartsby“PartNo.”-notby“KeyNo.” SERVICE NOTEToremoveBlowerAssembly:Unplug motor.Removethumbscrew(11)frommotorplateflange. FindthesingleTABonthemotorplate(locatednext tothereceptacle).Pushupnearmotorplatetabwhile pushingoutonsideofhousing.Orinsertastraight-blade screwdriverintoslotinhousing(nexttotab)andtwist screwdriver. Replacement parts can be ordered on our website. Please visit us at www.broan.com MODEL QTRE080R Page 7 MODEL QTRE080R Page 8 99044515B