Conzerv Power and Energy Meters NEW

advertisement
Conzerv Power and Energy Meters
NEW
L
®
Simultaneous Sampling of Volts & Amps
Programmable CT & PT ratios
Built-in Phase Analyzer
RS-485 Modbus Serial Port
‘One Touch’ Operation and Setup
Measure 4 Quadrant Power & 2 Quadrant Energy
Demand Monitoring (Optional)
Auto-Scrolling 3 Line, 4 Digit LED Display
Color-Coded Analog Load Bar (%A FS)
Wide Range Auxiliary Supply
DIGITAL
METERS
•
•
•
•
•
•
•
•
•
•
EM6400
SPECIFICATIONS
EM6459
• Displays Volts, Amps, Frequency / PF
simultaneously
• Monitors generator speed
• Monitors generator loading efficiency
EM6433
• Monitors load currents, active power &
energy consumption
• Displays Amps & Power simultaneously
EM6434
• Analyzes motor performance
• Monitors loading characteristics of motors
• Monitors motors efficiency
59
64
Par ame ter s
V1, V2, V3, V12, V23, V31
A1, A2, A3
Freq
% Load - Amps
% Unbal - Amps
Power Factor 1, 2, 3
RPM
Phase Angle 1, 2, 3
W1, W2, W3
VA1, VA2, VA3
VAR1, VAR2, VAR3
THD% on V1, V2, V3
THD% on A1, A2, A3
Demand W or VA
Rising demand, Max
Demand Time remaining
Hour of Max demand
INT: Wh
INT: VAh, VARh, -VARh
INT: Run hours
INT: Interruptions, On hours
INT W I/E: Wh
INT W I/E: VAh, VARh, -VARh
INT W I/E: Run hours
OLD: Wh
OLD: VAh, VARh, -VARh
OLD: Run hours
33
64
34
64
36 400
6
64
O
O
O
O
O
O
O
O
O
O = optional
EM6436
• Monitors active power & energy consumption, system voltage, load current and PF
• Displays Amps, Power, PF simultaneously
EM6400 All of the above plus:
• Optimizes demand utilization
• Analyzes power quality
• Helps energy balancing
Demand Parameters Option (EM6400)
• Monitors Demand – Present, Rising
& Maximum, Time remaining
• VA & W demand is selectable through
setup table
• Demand may be Sliding window (auto)
or Fixed window (User), selectable
through setup mode
• The time of occurrence for the Maximum
Demand is based on “On hrs” of the
system
• Maximum Demand can be cleared
independently or along with the
integrators through the CLR function in
the setup mode
Sensing:
Measurement:
True RMS, 1 sec update time
4 quadrant Power & 2 quadrant
Energy (4 quadrant optional)
Input voltage:
4 Voltage inputs
110 or 415 V L-L nominal
Range:
80 to 600V L-L
Input current:
3 current inputs,
field configurable 1A or 5A
Range:
20mA – 6A
Overload:
10A cont., 50A for 3 sec
Burden:
0.2VA max per Volts/Amps input
Frequency:
45-65Hz
Aux supply:
44-300 V AC/DC, 3VA max
Resolution:
RMS 4 digit, INTEG 8 digit
Communication: 2-wire RS-485, Modbus RTU
Demand:
Integration period 5-30 minutes
in 5 minute increments
Environment:
-10°C to +60°C operating,
5-95% RH non condensing
Dimensions:
96x96mm bezel, 80mm behind
panel
Measurement Accuracy (% Reading)
Volts L-N, L-L per phase & Avg
Amps per phase & Avg
Amps phase angle per phase
Frequency
Real Power per phase & total
Reactive Power per phase & total
Apparent Power per phase & total
Active Energy Import/Export
Reactive Energy
Apparent Energy
RPM
CL1.0
1.0
1.0
2°
0.1
1.0
2.0
1.0
1.0
2.0
1.0
1.0
CL0.5
0.5
0.5
1°
0.1
0.5
1.0
0.5
0.5
1.0
0.5
0.5
These meters can be setup using the front panel
or a free GUI based software utility.
ORDERING INFO
CZ/EM6459-xx
CZ/EM6434-xx
CZ/EM6436-xx
CZ/EM6400-xx
CZ/EM6400-xxPlus
Programmable Multi-function Meter: V, A, F, PF
Programmable Multi-function Power & Energy Meter
Programmable Multi-function Meter: V, A, F, PF, Power & Energy
Programmable Multi-function Meter
Programmable Multi-function Meter with Demand, THD & Bi-directional
xx specify either 1.0 or 0.5 Accuracy Class
34
NEW
Conzerv Power and Energy Monitors
•
•
•
•
•
•
•
Record and Analyze Power & Energy Data of Energy Intensive Loads
Auto Scrolling Display of up to 16 User Selectable Parameters
Separately Monitor Import/Export of Energy (optional)
Store Previous Period Integrated Data
Built-in Phase Analyzer
Data Maintained During Power Failure
6 Digit Readout for Energy Parameters, 4 Digit Readout for
Instantaneous Parameters
User Programmable
60 80 60
33 34 34
Feature
EM3360
EM3360
• Offers comprehensive power and energy monitoring
at feeders and individual loads
• Retrieves previous energy reading to cross check
utility meter readings or electricity bills
• Analyzes loading patterns
• Visualizes unbalances in system
• Checks for wrong connection, reversed phase
sequence, deteriorating power factor compensation
on one of the phases, etc.
EM3480
All benefits of EM3360 plus:
• Offers Demand Monitoring
• Ensures automatic synchronization of demand with
utility meter
• Displays Max demand along with date and time of
occurrence
• Helps to set realistic demand target
Voltage L-L per phase & average
Voltage L-N per phase & average
Voltage Neutral to earth
Current per phase & average
Neutral current
Phase Angle
%THD V1,V2,V3, I1,I2,I3
Line Frequency, Generator RPM
kW, kVA, kVAR per phase & total
PF per phase and 3 phase
kWh, kVAh, KVARh, Ah; avg: PF, Hz, V
Run hours & number of interruptions
Demand: instantaneous & maximum
Settable upper/lower limits & interval
3 Demand limit alarm outputs
High/Lo data store
High/Lo max. demand profile store
19 level Demand Target profile
Real-time clock w. On/Off & run times
Relay outputs for load control
User settable demand targets
All benefits of EM3480 plus:
• Predictive feature enables prior indication of
crossing demand
• Facilitates tripping of non essential loads
• Analyzes electrical faults & planning of load
schedules
• Optimizes demand utilization
• Improves system efficiency
These meters can be setup using the front panel or a
free GUI based software utility.
• EHT, HT or LT, Delta 2E or
Star 3E measurement; PT &
CT Ratios; kVA or kW
Demand
• VA measurement – 3D or
Arithmetic
• Demand Period (1 to 30
minutes)
• Manual Synchronization
(fixed window, to suit most
popular EB meters) or sliding window.
• Auto Synchronization: User
programmable password for
all Setup, Demand
Synchronization and Clear
Functions.
From Software:
• TOU calendar
• Monthly auto reset date
SPECIFICATIONS
Sensing:
EM3460
From Front Panel:
3 Phase, 3 Wire/4 Wire
(field configurable)
Measurement: True RMS
Voltage Input: 110 to 415 VAC nominal
Range:
80 – 500V
Current Input: 5 or 1 Amp nominal
(factory set)
Maximum:
120% of nominal
Burden:
0.2 VA Max.
Frequency:
50 Hz ± 5%, 60 Hz ± 5%
Auxiliary Supply: Factory Set, Single Phase,
240V (190-270V) or 110V
(85-130V), 5VA max.
Power Factor:
0.5 PF Lag – Unity – 0.8 PF
Lead
Accuracy:
For V, A, PF, all Power &
Energy parameters
Class 1.0:
± (0.2% of Full Scale +
0.8% of reading + 1 digit)
Class 0.5:
± (0.1% of Full Scale +
0.4% of reading + 1 digit)
Accuracy of Hz: ± 0.2% of reading
Accuracy of Ø: ± 1° (20% to 120% of Full
Scale)
Display:
7 digit, 0.56" LED,
auto scaling (kilo/Mega)
Temperature:
0° - 60°C operating
Dimensions:
Bezel 192 x 144mm,
110m behind panel
Panel Cutout:
186 x 138mm (+ 1.0 mm)
ORDERING INFO
Example: CZ/DM3360–1.0–5A–110–R–TOU–485–IE
Model
Accuracy
CZ/EM3360 Power & Energy Monitor
1.0
CZ/EM3480 Trivector Monitor
CZ/EM3460 Smart Demand Controller
34a
0.5
0.2
Input
1A
5A
Aux. Supply
Enable
VAC
Auto Reset
R=on
110
x=off
240
specify
date & time
Enable TOU
(x=off)
Comm Port Import/
(RS-485) Export
Energy
Energy+MaxDM
Energy+MaxDM+
DM Ctrl
485=install
x=none
IE=on
x=off
National Meter KW Hour Meters
Three Phase Energy & Demand Meters
Displays kWhrs and
kW Demand along with
Volts, Amps and real
time kW per phase.
K4000PM
SPECIFICATIONS
▲ KW4000
SPECIFICATIONS
Accuracy:
Burden:
Operating Temperature:
Relay Output:
RS-485:
Dimensions:
Enclosure:
Connections:
Dimensions:
Standards:
▲
• Six Digit kWh LCD Display
• L1, L2 & L3 Power Readings
• Three Digit V, A & kW Readout
• kWh Pulse Relay
• RS-485 Modbus RTU Output
• Use with CTs Rated to 10,000A
• 3Ø Revenue Class Meter
• 9 Digit LED Display
• Field Programmable
• Memory Backup Without
Batteries
• Direct Energy Display
– No Multipliers
ANSI C12.16
Isolated CT circuit, burden 0.06VA
-10°F to 120°F, <95% RH non-condensing
SPST Form A, 240VAC@10A resistive
4 wire
7.5"W x 8" H x 3.5" D
Surface mount, ABS plastic, NEMA 1
Screw terminals
5.6" W x 8.1" H x 3.5" D
UL61010B-1,CUL
Max Display:
Accuracy:
Burden:
Operating Temperature:
Relay Output:
Contacts:
Indicator:
Enclosure:
Dimensions:
Standards:
999,999,999 kWh
±0.5% ±2d
Isolated CT circuit, burden 0.75VA
-10°C to 50°C
Energy/alarm pulse, 1/sec max rate
440VAC, 10A, 2500VA resistive
Front panel LED
UL VO rated plastic, NEMA 1
3.78"W x 3.78" H x 3.3" D
CAT III 300V, Class II double insulated
ORDERING INFORMATION
CAT NO.
NM/KW4240
NM/KW4480
NM/K4240PM
NM/K4480PM
DESCRIPTION
120/208/240V 3Ø, 3 or 4 Wire, KWh/Demand Meter
277/480V 3Ø, 3 or 4 Wire, KWh/Demand Meter
120/208/240V 3Ø, 3 or 4 Wire, KWh Meter
277/480V 3Ø, 3 or 4 Wire, KWh Meter
400A solid core CTs included. Split core and larger sizes
available. Single phase models also available.
34b
Download