AEROVOLTAIC SOLAR ENERGY R-Volt Reversible energy www.systovi.com MADE IN FRANCE THE REFERENCE IN ENERGY INDEPENDENCE PATENTED SYSTEM IDEAL FOR N RENOVATIO Reversible effect Innovative air recovery offering four functions within a single system. 900 W (250 Wp + 650 W) The most advanced solar panel in the world. Guaranteed energy saving.. Certified Solar Keymark R-Volt 3 R-Volt HOW IT WORKS The aerovoltaic panels generate electricity and collect hot or cold air which is normally wasted. The MODUL-R filters and directs all air flows for heating or cooling. Air evacuation evacuates excess heat for your comfort and to ensure your system runs smoothly. The digital thermostat regulates the temperature of comfort and the operating modes. The electrical part is composed of an inverter and an AC Box. Blow vents provide fresh air and ensure you can relax at a comfortable temperature. R-Volt 5 R-Volt HOW IT WORKS MODUL-R Smart Management Unit of Energy. Centralize airflow and adapt it to your needs. MODUL-R is synchronized to your main heating system. The electronic card receives thermal data and thermostat instructions to manage the MODUL-R. Low consumption fan Variable flow from 100 to 400 m3/h. Motorized flat Opening automatically calculated according to the blowing setpoint. F5 filter purifies air up to 95 %. EcoBoost Low consumption electrical resistance. Brings +5 °C if necessary. R-Volt 7 ELECTRICITY GENERATION TOTAL FREEDOM OF INSTALLATION Ultra-integrated design « Flat surface » effect thanks to an edge to edge joint between the panels. Perfect homogeneity for a highly aesthetic finish on all roof types. 2 options to meet all your requirements On-roof design SYSTOétanche® technology (Patented) Monoblock rail and double sealed frame. Proven strength and reliability in all conditions. Technical appraisal of CSTB n°21/12-31 Hyper fast assembly with no change to the roof’s impermeability. Adaptable to all configurations while retaining an appearance as close as possible to the roofing. NEW 2015 L-Frame technology (Patented) Single sensor format that can be installed either vertically or horizontally. The inter-panel assembly guarantees high modularity and airtightness. R-Volt 9 ELECTRICITY GENERATION DOUBLE-SIDED ENERGY Generates electricity at the front, uses the air at the back Premium components High surface productivity (167W / m2) for optimal power generation. ‘On Roof Air Tightness’ Technology (Patented) Interlocking insulated rear collectors for tight air circulation throughout the solar field. Maximised air heating thanks to the turbulent flow and a single extractor outlet per sensor line. Mechanical ventilation under the panels Recovery of turbulent air flow (Patented « Turbulent Flow ») and permanent cell cooling. Great quantity of available heat, up to 10% more electricity and increased panel life. R-Volt 11 HEATING A SOURCE OF HEAT & SAVINGS Recovering hot air Innovative heating system. Create a comfortable environment and save up to 50% on your bill. EcoBoost mode +5°C in available heat. 30% more energy savings. *: Non-contractual estimate. Energy saving rate depends on the building insulation level and the heating needs. R-Volt 13 HEATING EFFECTIVE IN WINTER AND WHEN IT’S OVERCAST SUNNY WEATHER WITH NO CLOUDS MISTY CLOUDY VERY CLOUDY OVERCAST VERY OVERCAST March : 10 °C 42,8 °C 40,2 °C 31,9 °C 25,9 °C 22,4 °C 13,9 °C December : 5 °C 23,7 °C 22,7 °C 22,5 °C 11,2 °C 9,2 °C 7,1 °C Outdoor temperatures It clouds over, but the heat remains While a lovely sunny day is still the ideal situation, the arrival of clouds will not prevent your system from operating effectively. To give just one example, on a cloudy day with an outdoor temperature of 5°C in December, R-VOLT can blow hot air at over 22°C! That should bring down your energy bill, even during bad weather. Cold outside, warm inside under the panels When outdoor temperatures drop, the sun will continue to shine on the aerovoltaic panels. The panels collect the rays and convert them into heat, which will then be ingeniously harvested on the rear side by the Systovi patented air duct. Outdoor temperature 28,4 13,4 24,4 October 8,6 November December After 6pm, main heating system 24,8 23,5 12:00 20,3 EcoBoost EcoBoost 9,8 From 11am to 6pm, R-VOLT 38,3 36,6 Temperature of the aerovoltaic sensors * Produce heat throughout the day and enjoy it in the evening! Heat supplied by R-VOLT on a day in March 13,9 14,8 EcoBoost 6,2 January 7,3 February March April The EcoBoost effect: + 5 °C 15:00 18:00 21:00 00:00 6:00 09:00 Thermal intelligence How does your R-VOLT system share the workload with your central heating system? Well, in a smart and simple way. Most of the day, R-VOLT can heat your home without assistance. In addition, the hot air blown throughout your home will only dissipate slowly. You will therefore considerably reduce the length of time your central heating system is on and it will also come on much later! Mid-season, R-VOLT can even be used as your main heating system. Even from December to February, R-VOLT can blow hot air at 20°C despite the panels not reaching this temperature. This is because an electrical resistor boosts the thermal potential of the system. This means you can enjoy a comfortable temperature indoors while continuing to save energy! Smart Monitoring With our app, you can check the performance of your R-VOLT system in real time! Available on smartphones and tablets. * Measurements taken from a system rolled out in 01/03/12. The Coefficient Of Performance (COP) for the system remains above 3 (1 kWh input = 3 kWh output). R-Volt 15 HEATING NEED MORE HEATING ? ADD THE 750 W THERMAL BOOSTER. Self-sufficiency with R-VOLT Produce energy more cheaply than the network and use it yourself! This is your first step towards energy autonomy. Example of a 3 person 100 m² house in London : Recommended configuration 6 aerovoltaic panels 4 thermal boosters Find our recommended configurations depending on your installation on page 31. Premium components 3.2 mm solar glass with anti-reflective coating Selective aluminium solar absorber (98 % absorption) Polycarbonate air collector Patented turbulent flow R-Volt 17 NIGHT-TIME COOLING The free cooling effect The air collected under the panels is cooler than the outdoor air. By blowing this cool air into your home, after all-day heating, you can create a temperature difference which cools your home down efficiently and for free. HEAT DURING THE WINTER, COOL AIR OVER THE SUMMER Night-time cooling 4°C cooler than the outdoor temperature. Ideal night-time comfort, with the windows closed. Less than 30 decibels* Makes no noise when running. Cool nights = sleep tight. *: for an average blowing flow of 200 m3/h. R-Volt 19 PURIFY YOUR INDOOR AIR A NEW WORLD OF COMFORT Solar ventilation by blown air The ideal addition to mechanical ventilation systems. Benefit from purer air and extra energy savings. F5 filtration Air that is fresh and purified up to 95%. Protect your home and those living in it. Cold and damp air from indoors is expelled by the warm solar air. Cold outdoor air is stopped from entering Dual action mechanical ventilation Your mechanical ventilation system is designed to remove polluted air from your home, however it will not replace indoor air. R-VOLT makes up for this shortcoming through its large-scale supply of fresh air. R-Volt 21 HOT WATER PRODUCTION SYSTOVI & ATLANTIC group innovate together in hot water thermodynamic production By using preheated air from R-VOLT aerovoltaic panels, the thermodynamic water tank with solar air Odyssée 2 R-VOLT has a thermal efficiency 50 % higher than a regular thermodynamic water tank. This is the highest COP on the market. In addition, the electricity produced by the panels fully offset the residual consumption of the water tank. Hot water is 100 % free during the whole year! THE INDEPENDENT HOT WATER WITH THE OPTION ODYSSÉE 2 R-Volt Up to 100 % savings on hot water A maximized use of heat and electricity produced by R-VOLT aerovoltaic panels. R-Volt 23 YOUR OWN ENERGY, CHEAPER, AT CONSTANT PRICE AND ECO-FRIENDLY 100 % OF THE ELECTRICITY PRODUCED IS CONSUMED € ENERGY PRICE ENERGY SUPPLIER GREEN ENERGY CHEAPER THAN THE ENERGY FROM THE GRID NO KWH RISING PRICE FOR 25 YEARS R-VOLT SAME ADMINISTRATIVE PROCESSES AS REGULAR PV SYSTEMS TIME ELIGIBLE FOR THE FEED-IN-TARIFF (and other possible financial subsidies) Simulate Systovi solutions in your home Free app available on: Windows Store R-Volt 25 SUITABLE FOR ALL CONFIGURATIONS Even with converted attic, the MODUL-R can be easily installed in all houses (new or renovated buildings). INSTALLATION AT THE TIP OF THE AT TIC An access hatch to the attic is enough to easily install the R-VOLT sytem in the tip of the attic. The blow vents provide new air and real thermal comfort. Flexible installation Benefit from total freedom thanks to our connection solutions. From panels to air vents, with MODUL-R you can adapt our systems to any configuration thanks to our flexible set-up. Flat ducts enable to go down into the rafters. Wall plenum can be installed to distribute air from the ground. INSTALLATION UNDER THE AT TIC LOF T PLENUM WALL S PA C E F I T T I N G LO F T C E I L I N G S PA C E FITTING INSTALLATION IN AN UNCONVERTED LOF T IN A TWO-STOREY HOUSE (GROUND + UPPER FLOOR) INSTALLATION IN THE TECHNICAL CLOSET OF A TWO-STOREY HOUSE (GROUND + UPPER FLOOR) WITH A CONVERTED LOF T R-Volt 27 Technical specifications Airflow specifications 900 W 650 W 250 WP AIR FLOW AND REGULATION COMPONENTS Dimensions H x L x W (mm) Weight Envelope Inner trim Motors Fan Filter Mechanical specifications MECHANICAL DATA Dimensions (H x L x D) Sensor weight Solar cells Number of cells Origin of panels (encapsulation) Glass Rear surface Frame Maximum load Hail resistance 1518 x 1011 x 43 mm 17.5 kg (16 kg/m2) 6.2’’ (156 x 156 mm) monocrystalline Si cells 54 France (Saint-Herblain - 44) 3.2 mm with anti-reflective coating Black composite film Black anodised aluminium Advanced test up to 5400 Pa as per IEC 61215 Up to a diameter of 25 mm with an impact speed of 23 m/s INTEGRATION DATA Orientation Roof Roof angle Min. slope required (including flashing) Integration standard Portrait All types 15° - 60° (up to 6° for complete roof, subject to conditions) 3.4 m (min. 2 rows of panels) IAB, all roofs, including slate (< 2 cm) 250 -2/+2% 16.5% 1000 V 17 A 28.84 8.502 34.40 8.811 15 47°C from -40°C to 85°C -0.346 %/K 0.036 %/K -0.47 %/K -7 °C/ 60 °C Heating mode 65 °C 400 m3/h: circular vent diam. 330 mm - 200 m3/h: circular vent…. Rectangular plenum, 400 m3/h or 200 m3/h Wall Electric Power supply 230 VAC Electrical protection Class II Capacity (L) 270 Power supply 230 V Total power input (W) 2,550 Resistance (W) 1,800 591 2.76 4.07 (2) Standard heating time 11h32 6h35 Solar air heating time(3) Dimensions H x D x Ø (mm) 1950 x 674 x 591 Empty weight (kg) 90 Clear line-of-sight noise level at 1 metre (dB(A)) 37 Coolant R134a (1) COP according to EN 16147 - Setpoint ≥ 52.5 °C - Outdoor air 7°C; (2) Value corresponding to 6 R-VOLT panels in zone H2b; (3) Outdoor air 7°C - Setpoint 55°C - Irradiation 700 W/m²; single-phase connection only Acoustic specifications 10-year warranty ACOUSTIC PRESSURE 2-year warranty Clear line-of-sight - Measured 1 m from the air intake point of the MODUL-R ELECTRICAL POWER 10-year warranty 25-year warranty Technical notice - 21/12-31 SYSTOétanche® Heating, cooling, PV ventilation, frost protection Unit location Ceiling Air intake vent mean annual solar COP PRODUCTS Solar Keymark certification Licence 078/000227 Operating mode Max./min. operating temperatures COP(1) Warranties 90% 80% Thermostat Control HYDRAULIC COMPONENTS - ODYSSÉE 2 - R-VOLT THERMODYNAMIC WATER HEATER ELECTRICAL EFFICIENCY R-VOLT aerovoltaic panels Mounting system, integration and seal Airflow components EcoBoost Hydraulic specifications Electrical specifications Pmax (Wp) Power tolerance Yield Max. system voltage, Vmax (U) Max. system current, Imax (A) Vmpp (V) Impp (A) Voc (V) Isc (A) Reverse-current protection IRM (A) Normal operating cell temperature (NOCT) Operating temperature (OC) Temperature coefficient (Voc) Temperature coefficient (Isc) Temperature coefficient (Pmax) Modul-R construction 380 x 550 x 500 10 kg PPE - expanded polypropylene PPE - expanded polypropylene Servomotor 2 Nm/230 VAC Low-consumption variable speed, 100 m3/h - 400 m3/h F5 for incoming air - F7 as an option between Modul-R and air intake point 250 W - heating mode triggered if min. under-panel temperature >15 °C Shutdown if under-panel temperature > 23 °C - Max. air flow with Ecoboost active: 150 m3/h Digital wireless 1950 THERMAL: ELECTRICAL: 674 PMAX (W) r-volt IEC 61215 ed. 2 certificate 61730 certificate Air flow (m3/h) 100 200 300 400 Noise (dbA) 10 27 37 44 PV Cycle membership Modules 85% recycled R-Volt 29 Thermal specifications r-volt MEAN MONTHLY SOLAR IRRADIATION (W/M²) AND IMPACT OF CLOUD COVER THERMAL PERFORMANCE AS A FUNCTION OF THE DISTANCE TRAVELLED BY THE AIR Yield (%) and temperature of intake air (°C) - Irradiation 600 W/m², orientation 180° south, gradient 30°, wind 1.5 m/s Solar irradiation values can be used to assess the energy potential of a geographic zone. Solar irradiation will vary depending on the location of the zone, but will also be affected by cloud cover. The following graphs show mean monthly values for 4 towns, each located in one of the 4 thermal zones of France. ZONE 1 - NORTH: Lille, London, Rotterdam, Brussel... ZONE 2 - CENTRAL NORTH: Paris, Strasbourg, Zurich, Munich... ZONE 3 - CENTRAL SOUTH: Lyon, Geneva, Milan, Venice... ZONE 4 SOUTH: Bilbao, Barcelona, Marseille, Florence... Intake via 2 rows Type of cloud cover Solar irradiation (W/m²) 1,000 Type of cloud cover ZONE 2 - CENTRAL NORTH 40 Air flow: 100 m3/h Air flow: 200 m3/h Air flow: 400 m3/h Intake via 1 row 30 Intake via 1 panel 20 Intake via 3 rows Intake via 2 rows Air flow: 400 m3/h Intake via 1 row 30 ZONE 1 - NORTH Temperature of the intake air (°C) Intake via 3 rows 40 Source: PVGIS - Measurements taken at noon. Solar irradiation (W/m²) Yield (%) Intake via 1 panel Air flow: 200 m3/h 20 Air flow: 100 m3/h 10 1,000 No cover 800 600 No cover 800 600 Moderate cover 400 Moderate cover 10 0 0 1 2 400 200 Overcast Values approved by Solar Keymark as per EN ISO 9806:2013 Licence 078/000227 Ja n. Fe b. M ar ch Ap r. M ay Ju ne Ju l. Au g. Se pt . Oc t. No v. De c. Ja n. Fe b. M ar ch Ap r. M ay Ju ne Ju l. Au g. Se pt . Oc t. No v. De c. 0 Solar irradiation (W/m²) Type of cloud cover ZONE 3 - CENTRAL SOUTH Solar irradiation (W/m²) 1,000 Type of cloud cover ZONE 4 - SOUTH No cover 600 No cover 600 400 Moderate cover 400 200 2 3 4 5 Distance travelled by the air (m) Air flow / column (m3/h) 102 m3/h 622 519 416 117 m3/h 661 554 447 REFRIGERATION ENERGY EFFICIENCY RATING (EER) 800 Moderate cover 75 m /h 523 433 342 3 < 1 m/s 1.5 m/s 3 m/s Wind speed (m/s) 1,000 800 1 POWER (W) PER PANEL - IRRADIATION 1,000 W/M² 200 Overcast 0 3 4 5 Distance travelled by the air (m) Outdoor temperature at night (°C) Panel output temperature (°C) - peak Indoor temperature at night (°C) Intake air flow (m3/h) System power consumption (W) 18°C 15°C 26°C Intake air refrigeration power (W) EER 200 m3/h 27 W 400 m3/h 122 W 660 W 1300 W 24 11 200 Overcast Overcast RECOMMENDED CONFIGURATION FOR SELF-CONSUMPTION ACCORDING TO THE THERMAL ZONE 0 House Ja n. Fe b. M ar ch Ap r. M ay Ju ne Ju l. Au g. Se pt . Oc t. No v. De c. Ja n. Fe b. M ar ch Ap r. M ay Ju ne Ju l. Au g. Se pt . Oc t. No v. De c. 0 ZONE 1 ZONE 2 ZONE 3 ZONE 4 6 R-VOLT panels + 2 thermal boosters 6 R-VOLT panels Hot Water Option THERMAL PERFORMANCE AS A FUNCTION OF SOLAR IRRADIATION Maximum air intake temperature (°C) and maximum heating power (W) - Configuration: 2 rows x 6 columns, orientation 180° south, gradient 30°, wind 1.5 m/s OUTDOOR TEMPERATURE -5°C 0°C 5°C 10°C Up to 100 m² (3 people) 6 R-VOLT panels + 4 thermal boosters 15°C SOLAR IRRADIATION Max. temp. (°C) Max. power (W) Max. temp. (°C) Max. power (W) Max. temp. (°C) Max. power (W) Max. temp. (°C) Max. power (W) Max. temp. (°C) Max. power (W) 200 W/M² 0 0 0 0 0 0 24 678 24 986 300 W/M² 0 0 0 0 23 892 28 1480 28 1480 400 W/M² 0 0 22 1106 27 1302 27 1973 32 1973 500 W/M² 22 1320 27 1388 27 2466 32 2466 37 2466 600 W/M² 26 1534 26 2959 31 2959 36 2959 41 2959 700 W/M² 25 3453 30 3453 35 3453 41 3453 45 3453 800 W/M² 30 3946 35 3946 40 3946 45 3946 50 3946 900 W/M² 34 4439 39 4439 44 4439 49 4439 54 4439 1,000 W/M² 38 4932 43 4932 48 4932 53 4932 58 4932 100 to 150 m² (4 people) More than 150 m² (5 people) 8 R-VOLT panels + 4 thermal boosters 8 R-VOLT panels + 2 thermal boosters 8 R-VOLT panels 10 R-VOLT panels + 4 thermal boosters 10 R-VOLT panels + 2 thermal boosters 10 R-VOLT panels Thermodynamic water tank Odyssée 2 R-VOLT + 2 R-VOLT panels EcoBoost active: value including +5°C added to the temperature under the panels, up to 150 m /h, (inactive between 150 and 400 m /h). 3 3 R-Volt 31 Systovi is a French manufacturer and designer of home solar solutions. Its innovative systems can reduce your energy bills and improve your standard of living indoors. The company invented aerovoltaic technology and pays particular attention to selecting components for them and installing them. Systovi products are designed and manufactured in France (Saint-Herblain), and distributed in Europe and North America. MCS Certifications 10/12 Civil liability 10-year warranty ISO 9001 & 14 001 Solar Keymark Certificate Licence 078/000227 IEC 61215 ed. 2 certificate 61730 certificate Technical notice no. 21/12-31 Recycling of all modules at end-of-life Winner of the 2012 Trophy in the Environment category Winner of the Grand Prix de l’Innovation 2013 In the Energy Efficiency category www.syst ov i .co m © SYSTOVI - Siège social : 5 rue du Chêne Lassé - CP 1008 - 44 806 Saint-Herblain Cedex - France - Conception : Bruno Davy Design - Troisième Axe - Brochure R-VOLT Edition de 02/2015 Energy independence through innovation