GL01 - American Green Technology

advertisement
GL01
REV:
INDUCTION
GARAGE SITE & CANOPY LIGHTING
JUL / 09 / 2014
OVERVIEW
AGT's multi-purpose Garage Site / Canopy Light with a clear lens is suitable for wall, ceiling or pendant
mount and the low profile height is ideal for low clearance applications; even warehouse or stairway
lighting. The highly polished aluminum reflector and prismatic lens spread even illumination over a
broad area. The die-cast aluminum housing is powder coated for durability and high corrosion
resistance while the hinged mounting plate makes installation easy. The modular design allows
dimming, emergency backup or daylight harvesting options to be added easily to the unit. The solid
state generator case is separated from the lamp compartment.
The GL01 is rated IP53 with a weather seal gasket to seal the lens and can be upgraded for IP65
applications. The induction lamp provides outstanding lumen maintenance and a rated lamp life of
100,000 hours.
Dimensions
IP Rating
Wattages
Voltage
Mounting System
Housing
Lens
Reflector
Emergency Backup
15 ½ x 15 ½" and 11" Tall
53 (IP 65 upon request)
40-150W
120-277V; 347V
Ceiling or Wall Mount; ½ “ hole for Pendant Mount
Cast Aluminum
Polycarbonate
Polished Aluminum
7W LED, 90 minute for all wattages
15 ½”
11 ”
N/A
N/A
PROJECT
TYPE
WATTAGE 1
PRODUCT
VOLTAGE
KELVIN
FIX. COLOR
LENS
CORD
SURGE
FUSE
N-None
SP
N-None
F-15A
SENSORS 6
BACKUP 7
GL01
40
60
80
100
120
150 2
80 DIM 3
100 DIM 3
UNV-120 to 277V; 250v DC 4
3-347V
5K-5000
27K-Custom 2700
35K-Custom 3500
41K-Custom 4100
65K-Custom 6500
CL-Clear Lens (Standard)
CO-Conical Lens
CR-Circular Lens
BZ-Pole Bronze (Standard)
CC-Custom color (contact sales)
NOTE: All fields must be completed.
NOTE: Refer to separate Sensors Reference Sheet for in-depth controls information.
1
Wattages listed are standard. Other wattages may be available upon request
150 watt option is ONLY available with the CL-Clear Lens or CR-Circular Lens option. Please be
sure to select either CL or CR for lens option if 150 watt is desired.
3
If step dimming is required add "DIM" to the wattage. DIM generator can be operated
with a 0-10V DC controller.
4
Universal generator can also accept direct feed 250V DC. Please contact Sales for more
information.
5
5-wire cord is optional for dimming systems.
6
Photocells and Dimming sensors can be ordered separately or together. Be sure to select
your desired option.
7
Emergency Backup option is 7W LED downlight with 90 minute battery.
2
APPROVALS
INFO
N-None
MS-Motion Sensor
PC120-PC120 ONLY
PC277-PC277 ONLY
DS-Dimming Sensor ONLY
PC120-DS-PC120 WITH Dimming
PC277-DS-PC277 WITH Dimming
N-None
C1-3 Wire cord - 1 foot long
Cx-Custom 3 wire cord x feet long
CD1-5 Wire cord - 1 foot long 5
CDx-Custom 5 wire cord x feet long 5
N-None
E-Emergency Backup 7
10 Year Limited Warranty
UL cUL 1598 Standards
ETL CUS Listed
10
© 2014 American Green Technology 52129 State Route 933 South Bend, IN 46637 (269) 340 - 9975 info@agtus.org www.agtus.org
CM
IP53
GL01
INDUCTION
GARAGE SITE & CANOPY LIGHTING
Continued
REV:
JULY / 9 / 2014
LAMP FEATURES
LAMP SPECIFICATIONS
POLAR CURVE - 100W Clear Lens
High quality phosphor coating for
superior lumen maintenance
Rated Lamp Life
100,000 hrs.
High lighting efficacy, instant on,
instant restrict, solid amalgam, and
stable color over long life
Kelvin
2,700 - 6,500 k
Excellent vibration and shock
resistance with unlimited switching
* The below chart compares general depreciation trends
of different lighting technologies under similar conditions.
Actual depreciation may vary and is dependent upon a
number of environmental factors, the manufacturer and
the application in which the luminaire is used.
100%
Vertical and horizontal planes through the 834 Cd. maximum
intensity point
Lumen Maintenance
Minimum 70% @ 80,000 hrs.
90%
80%
70%
60%
MH
50%
0
hrs.
10k
hrs.
20k
hrs.
FL
40k
hrs.
HPS
50k
hrs.
INDUCTION
LED
60k
hrs.
70k
hrs.
80k
hrs.
90k
hrs.
* This photometric chart shows the characteristic lighting
distribution of this luminaire. Please refer to the specific IES
file for more detailed information.
100k
hrs.
SOLID STATE GENERATOR SPECS
Input Voltage
Power Factor
THD
Standard Voltage
Minimum Input Voltage
Maximum Input Voltage
Minimum Input Frequency
Maximum Input Frequency
Inrush Current
Minimum Output Frequency
Nominal Output Frequency
Maximum Output Frequency
RoHS 5 Compliance
Protection - No Load
Protection - Load Short
Protection - Lamp Removed
120 - 277V Universal (UNV),
24V DC, 347V
> .96
< 10%
120 - 277 (Volts AC)
98 (Volts AC)
305 (Volts AC)
47 (Hertz)
63 (Hertz)
< 60 (Amperes)
210 (KiloHertz)
240 (KiloHertz)
270 (KiloHertz)
Yes
Yes
Yes
Yes
Cold Temperature Start
Max Case Temperature
Isolation Resistance - Hot State
Isolation Resistance - Cold State
Isolation Voltage
Ignition Voltage
Differential Mode
Cooling
Generator
Harmonic Current
Electromagnetic Emission
ESD
Electromagnetic Compatibility Immunity
Entire Luminaire
IP Rating & Safety
(Ta) -25 (Standard), -40 (Upon Request)
(Tc) 160F
< 200 Megaohms
500 Megaohms
2,000 Vac (S 10ma) 10s
2,700 +/- 200Vpp
+/- 1kV
Natural
UL935, CAN/CSA-C22.2 No. 74-96,IEC(EN)61347-1,
EN61347-2-3, GB19510.4, GB19510.1
ANSI C82.11,IEC(EN)61000-3-2, GB17625
FCC CFR part18/EN55015/CISPR15/GB17743
IEC 61000-4-2 Level3
IEC61547/EN61547, EN61000-3-3,EN61000-4-5,
GB17743
UL1598, CSA-C22.2 No. 250.0-08
IEC(EN)60598,IEC60529,GB7000,GB4208
WATTAGES
TOTAL LOAD 1
VEL 2
INITIAL LUMENS
LUMEN RANGE 3
LAMP (LM/W)
CRI
HID REPLACEMENT
40 W
60 W
80 W
100 W
120 W
150 W
42 W
63 W
84 W
105 W
126 W
157.5 W
5,488
8,232
11,760
15,680
18,780
23,520
2,800
4,200
6,000
7,500
9,600
12,000
2600 - 2800
3900 - 4200
5600 - 6000
7000 - 7500
9000 - 9600
11250 - 12000
65 - 70
65 - 70
70 - 75
70 - 75
75 - 80
75 - 80
> 80
> 80
> 80
> 80
> 80
> 80
80 / 100 W
120 / 150 W
150 W
200 W
250 W
300 / 325 W
1
2
3
Total load equals the maximum wattage used by both the lamp and the generator
Visually Effective Lumens factor of 1.96
Lumen Range is based upon generator wattage that is supplied to the lamp. See IES file for more details
© 2014 American Green Technology 52129 State Route 933 South Bend, IN 46637 (269) 340 - 9975 info@agtus.org www.agtus.org
INFO
Download