REAL RESULTS Reservoir Monitoring with DTS Reduces Operating Costs by Optimizing Gas Lift Operation and Flow Assurance Objectives • Provide deepwater flow assurance and gas-lift monitoring along with production surveillance on a six-well deepwater project. Results • Distributed temperature sensor (DTS) surveys and pressure/temperature (P/T) data were used to accurately identify “cool down” times, the amount of time that a well or flowline can be left untreated before hydrate formation becomes an issue. • DTS Data was then used to optimize wax inhibitor injection by identifying when riser temperatures reached the point where wax inhibitors were required. • DTS measurements were additionally used to establish the operating parameters for the gas-lift system, providing information to determine that gas-lift valves were operating correctly. On this deepwater, six-well monitoring program, Weatherford’s field-wide installation of optical sensing systems provided essential information for production optimization. Location Offshore, Gulf of Mexico Well Type Deepwater TLP platform Water Depth 4,300 ft (1,311 m) Value to Client • Using optical temperature monitoring systems saved the operator money by optimizing the paraffin inhibitor program and reducing the need for costly chemical remedial treatments that the formation of paraffins and hydrates in these wells would have required. Products/Services • DTS analysis • Optical reservoir monitoring system • DTS measurements also helped establish the optimal operating parameters of the live gas-lift valves before installation, enhancing efficiency and providing additional time and money savings. Weatherford International Ltd. 515 Post Oak Blvd., Suite 600 Houston, Texas 77027 USA Tel: 713-693-4000 weatherford.com Weatherford.com/optics Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client. © 2008 Weatherford. All rights reserved. 4965.00 REAL RESULTS Flowing 2 hrs 4 hrs 6 hrs 8 hrs 10 hrs 12 hrs 18 hrs Weatherford's well monitoring with DTS provides temperature measurements every 3.3 ft (1m), which enables continuous temperature logging of the well, above and below the seabed. Gas-lift valve operation monitoring with DTS. Weatherford’s DTS data viewer is used for qualitative analysis of DTS survey data, such as analyzing gas-lift valve operations. For more information on this subject, please see SPE 95798. Weatherford International Ltd. 515 Post Oak Blvd., Suite 600 Houston, Texas 77027 USA Tel: 713-693-4000 weatherford.com Weatherford products and services are subject to the Company’s standard terms and conditions, available on request or at weatherford.com. For more information contact an authorized Weatherford representative. Unless noted otherwise, trademarks and service marks herein are the property of Weatherford. Specifications are subject to change without notice. Weatherford sells its products and services in accordance with the terms and conditions set forth in the applicable contract between Weatherford and the client. © 2008 Weatherford. All rights reserved. 4965.00