Current Firmware Revision: 1.06.0000-b005 The following notes provide the revision history, list of known issues, and added features in the current firmware release. For more information please call your Extron Application Engineer. Updated: July 15, 2015 Extron Products Affected: IPL Pro S1 IPL Pro S3 IPL Pro S6 IPL Pro IRS8 IPL Pro CR88 IPCP Pro 250 IPCP Pro 250 W/Link License IPCP Pro 350 IPCP Pro 350 W/Link License IPCP Pro 550 IPCP Pro 550 W/Link License DTP CrossPoint 84 IPCP SA DTP CrossPoint 84 IPCP SA W/LL DTP CrossPoint 84 IPCP MA 70 DTP CrossPoint 84 IPCP MA 70 W/LL IN1608 IPCP SA IN1608 IPCP SA W/Link License IN1608 IPCP MA 70 IN1608 IPCP MA 70 W/Link License 60-1412-01 60-1413-01 60-1414-01 60-1415-01 60-1416-01 60-1429-01 60-1429-01A 60-1417-01 60-1417-01A 60-1418-01 60-1418-01A 60-1368-12 60-1368-12A 60-1368-13 60-1368-13A 60-1238-12 60-1238-12A 60-1238-13 60-1238-13A TECH NOTES Updating firmware – IP Link Pro firmware can be updated from Extron’s Toolbelt utility. Additionally, the firmware can be updated without additional software via the embedded web pages in IP Link Pro control processors. Please consult the User’s Manual for more information on uploading via the embedded webpages. Minimum Firmware Versions in Controller Groups – When a controller group is formed, the same version of firmware must be loaded to all members of the controller group. Page 1 49-247-50 Rev. 1.06.0000-b005 KNOWN ISSUES The following is a list of known firmware issues found in the IP Link Pro firmware version 1.06.0000-b005 Issue (originated in 1.06.0000-b005) – Switched 12VDC Power Ports status not working – The combined load and combined wattage feedback state is not working, if configured for status nothing is returned. Issue (originated in 1.00.0008) – RS-485 not working properly - RS-485 mode is currently not working properly. Issue (originated in 1.00.0008) - Updating Firmware, order of operations for controller groups – When updating controller firmware on a running system configured with controller groups, the primary controller must be the last device updated. Failing to follow this order of operations can result in the secondary controllers losing status for serially controlled devices. This issue may also occur in the event that a secondary controller is power cycled independently of the primary controller. Solution: Power cycling the primary controller will restore the lost status for serially controlled devices. Page 2 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.06.0000-b005 Affects: Firmware Revision: 1.05.0001-b001 Date: Units shipped prior to July 15, 2015 The following is a list of changes and fixes in this release. Added Feature – Support for the TLP Pro 1520 Series - Firmware version 1.06.0000-b005 is the minimum firmware version required for use in systems which contain the TLP Pro 1520 series of touchpanels. Added Feature – Support for the TLP Pro 1220 Series - Firmware version 1.06.0000-b005 is the minimum firmware version required for use in systems which contain the TLP Pro 1220 series of touchpanels. Fixed Issue (originated in v1.05.0001-b001) – Digital output port default condition – Flex I/O and digital I/O ports configured as digital output ports would default to the “on” state following a power cycle. This issue has been resolved, the port will default to the “off” state following a power cycle. Fixed Issue (originated in v1.00.0008) – Sending mail without email server configured – If a system is configured to send email without an email server provided the touchpanel within the system would stop responding. This issue has been resolved. Page 3 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.05.0001-b001 Affects: Firmware Revision: 1.04.0000-b201 Date: Units shipped prior to May 29, 2015 The following is a list of changes and fixes in this release. Added Feature – Support for the TLP Pro 320 Series - Firmware version 1.05.0001-b001 is the minimum firmware version required for use in systems which contain the TLP Pro 320 series of touchpanels. Fixed Issue (originated in v1.00.0008) – Improved system stability – In some systems Touchpanels and/or VTLP will periodically display “waiting For Sync” and would require the primary control processor in the system be power cycled or rebooted via Toolbelt to restore connectivity. The frequency of this problem has been significantly reduced and should no longer occur in most cases. Page 4 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.04.0000-b201 Affects: Firmware Revision: 1.03.0000-b002 Date: Units shipped prior to March 30, 2015 The following is a list of changes and fixes in this release. Added Feature – GlobalViewer Enterprise Support – Firmware version 1.04.0000-b201 is the minimum firmware version required for integration of IP Link Pro control processors and GlobalViewer Enterprise 2.2. Fixed Issue (originated in v1.03.0000-b002) – Gigabit LAN LED status not working on IPL Pro CR88 – Gigabit LAN LED status on the IPL Pro CR88 controller does not function when connected to a gigabit switch. This issue has been resolved. Fixed Issue (originated in v1.03.0000-b002) – IPL Pro IRS8 and IPL Pro CR88 displaying incorrect model – When discovered using Extron Toolbelt software both the IPL Pro CR88 and IPL Pro IRS8 would display as the IPCP Pro CR88 and IPCP Pro IRS8. This issue has been resolved. Fixed Issue (originated in v1.00.0008) – During a build and upload process, software frequently triggers an error “Hardware is in an unknown state.” – In some combinations of firmware and software, GCP would report “Hardware is in an unknown state” even when the computer running the software had no network issues when attempting to connect to the intended hardware. The frequency of this problem has been significantly reduced and should no longer occur in most cases, but it requires using both the latest software and latest firmware. This issue has been resolved in GCP version 1.3.0 in combination with control processor firmware 1.04.0000-b201. Page 5 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.03.0000-b002 Affects: Firmware Revision: 1.02.0000-b002 Date: Units shipped prior to November 24, 2014 The following is a list of changes and fixes in this release. New Product Support – Minimum firmware required for IPL Pro IRS8 and IPL Pro CR88 – This is the initial shipping firmware version for the IPL Pro IRS8 and IPL Pro CR88 control processors. Fixed Issue (originated in v1.00.0008) – Intermittent performance issues in systems – Temporarily removing or power cycling Ethernet controlled devices at run time causes delayed feedback and slows performance. This issue has been resolved. Page 6 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.02.0000-b002 Affects: Firmware Revision: 1.01.0000-b007 Date: Units shipped prior to September 26, 2014 The following is a list of changes and fixes in this release. New Product Support – Minimum firmware required for IPCP Pro 250 – This is the initial shipping firmware version for the IPCP Pro 250. Fixed Issue (originated in v1.00.0008) – Wake on LAN support intermittent – The WOL (Wake on LAN) driver fails to execute every time the command is sent. This issue has been resolved. Page 7 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.01.0000-b007 Affects: Firmware Revision: 1.00.0008 Date: Units shipped prior to July 31, 2014 The following is a list of changes and fixes in this release. Fixed Issue (originated in v1.00.0008) – Failure to activate LinkLicense for the DTP CrossPoint 84 IPCP and IN1608 IPCP models – The DTP CrossPoint 84 IPCP and IN1608 IPCP models fail to validate Extron LinkLicense upon upload via Toolbelt. This issue has been resolved. Fixed Issue (originated in v1.00.0008) – Touchpanel performance in controller groups declines after approximately 24 hours post configuration – Touchpanel performance would decline after a configuration upload, slowing down the responsiveness of page flips, text feedback and button state changes. This issue has been resolved. Improved HTTP Driver Support – Added support for HTTP device drivers that require session management, custom headers and XML parsing. Page 8 49-247-50 Rev. 1.06.0000-b005 FIRMWARE RELEASE HISTORY Released Version: 1.00.0008 Affects: Firmware Revision: N/A Date: April 30, 2014 The following is a list of changes and fixes in this release. Initial Release – This is the initial release of this software product. Page 9 49-247-50 Rev. 1.06.0000-b005