INSTALLATION OF PREMIER SWIVEL TOWEL

advertisement
INSTALLATION OF PREMIER SWIVEL TOWEL WARMER
For Warm Fluffy Towels
SPECIFICATIONS
Model WPS620C (or CTWC)
Model WPS620W (or CTWW)
Voltage 240 VAC Chrome Rating 56 Watts at 240 Volts AC
Voltage 240 VAC White Rating 80 Watts at 240 Volts AC
OPERATION
Your Premier Towel Warmer uses only minimal electrical power - about the same as an average light bulb. It will take
approximately 20-30 minutes to reach maximum operating temperature. For best results, only two generous sized towels should
be heated at one time. The heat of this unit may increase significantly if overloaded with an excessive number of towels.
CAUTION
Prior to installation please ensure the product is to your satisfaction. Once installed Heirloom cannot be responsible for defects
in the product finish that would have been apparent at that time. This Appliance is not intended for use by young children or
infirmed persons without supervision. Young children should be supervised to ensure they do not play with the
appliance. Do not plug the towel warmer into the power supply until installation is complete.
This package contains:
1 towel warmer frame and flex with 3 Pin plug
2 Premier mounting body assemblies
2 assembly screws
2 wall mounting brackets
2 grub screws
4 decorative trim rings (2 Gold 2 Chrome)
4 wall mounting screws
Fig 1
ASSEMBLY & INSTALLATION INSTRUCTIONS
1. Please ensure your towel warmer is installed by a registered electrician and ensure the electrical supply, plug & switch location,
and product location will comply with your local regulations. Attach the Premier Mounting Body assemblies to the towel
warmer frame, as shown in Fig 1: Fit the cavity in the Mounting Body over the hinge upturn on the towel warmer frame,
making sure that the two holes in the Body line up with the two holes in the hinge upturn. Using the assembly screws,
secure the body to the frame. Use the plastic sleeve supplied to hold the screw onto the tip of the screwdriver.
Ensure that the screw is completely tightened. Repeat for the second Main Body assembly.
2.
The Premier Swivelling Towel Warmer can be mounted with the wall mounting on either the left or right hand side of
the warmer frame, with the cable entry positioned at the bottom. The towel warmer should be at least 55mm below the
ceiling or any overhanging surface, and at least 300mm above the floor or 40mm above counter top. Screw the
mounting brackets to the wall vertically above each other at 415mm centres (Use the template supplied). The
mounting brackets should be fixed through the wall cladding direct to a stud (or other suitable anchor material). For
maximum strength pre-drill all screw holes before fixing. Use nylon plugs for brick or masonry walls. If unable to screw
into studs, use Toggle Anchors for cavity walls.
NOTE: On plaster board walls over tightening mounting bracket screws may pull the fixing bracket into the wall surface
thereby preventing correct bracket/body engagement. To overcome, fit washers (same diameter as bracket width)
under fixing bracket to pack it out flush with the wall surface.
3.
Place the trim ring over the mounting bracket. Position body assemblies per Fig 2 and
carefully tighten grub screws.
ELECTRICAL INSTALLATION
Note: to avoid hazard, the power supply cord must only be replaced by a qualified person.
Please ensure your towel warmer is installed by a registered electrician and ensure
the electrical supply, plug & switch location, and product location will comply with
your local regulations. New Zealand electrical wiring requirements stipulate that this
appliance must be wired by a registered electrician in accordance with current
electrical wiring regulations. This appliance must be fitted with an air gap phase
isolation switch. For complete temperature control a wall mounted dimmer switch
(with “off” position) is recommended.
PREMIER SWIVEL NZAust v2.03.doc
PREMIER SWIVEL TOWEL WARMER
For Soft Fluffy Towels
Locating Instructions
Detailed installation instructions are provided on the reverse side. The Premier Swivel Towel Warmer
should be fixed through the wall cladding directly to studs or other suitable anchor material. It should
be at least 55mm below the ceiling or any overhanging surface and at least 300mm above the floor
or 40mm above counter top.
The Towel Warmer should be fixed through the wall cladding directly to studs or other suitable
anchor material. The towel warmer should be located in compliance with local electrical codes and
regulations by a qualified person. The warmer should not be located in the direct path of a water
source (tap or shower etc)
A towel warmer is designed to warm and assist the drying of towels and will normally operate at a
temperature that is too hot for the warmer to be grasped for an extended time
Care and Cleaning
All components are made from high quality materials. The epoxy resin (white) or chrome finish of
your Towel Warmer is hard wearing and easily maintained. Clean regularly with a soft cloth and nonabrasive cleaning agent. Do not use ammoniated detergent, metal or abrasive cleaning agents.
Guarantee
This product is guaranteed against defects due to faulty workmanship or materials for 5 years from
date of purchase. In the event of a defect in the product, it should be returned with the sales receipt to
the retailer from whom it was purchased. Under the guarantee the defective article will be repaired or
replaced at Heirloom’s option – free of charge. Costs of disconnection, reconnection, and freight are
the responsibility of the owner, as is any damage arising in transit to and from servicing.
This guarantee does not cover:
a. Any damage to the product caused by misuse, neglect, accident, or in violation of the
manufacturer’s instructions, or
b. Any damage, loss or injury arising as a consequence of the use of the product.
Contact Us
We welcome your feedback on our products. You can view our full range of towel warmers on our
website and send us your comments about this product to info@heirloom.co.nz
Heirloom International Limited
P O Box 204 235, Manukau 2161
New Zealand.
www.heirloom.co.nz
PREMIER SWIVEL NZAust v2.03.doc
Download