SINETAMER. ESPECIFIACIONES EQUIPOS COMERCIALIZADOS POR EDC SUPPLY y
RESPALDADOS POR EDCEECA EN VENEZUELA
SUPRESOR PRINCIPAL DE 300 KA. ST-SMLA 3N4
TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST TRANSIENT INPUT
AND LIGHTNING. -DISCHARGE CAPACITY: 300 KA PER PHASE (EXCLUSIVE): TRANSIENT
VOLTAGE SUPPRESSOR, A UNIT INSTALLED IN PARALLEL WITH 480 VAC INPUT VOLTAGE,
DELTA, 3 PHASE, 60 HZ FEATURES: INPUT VOLTAGE: 480 VAC, 3F DELTA (03 + PE). WITH
KIND AND INSTALLATION. -DISCHARGE CAPACITY: 300 KA PER PHASE. -DIAGNOSIS OF
CIRCUITS: BRIGHT LED, NORMALLY ON. -6 PROTECTION MODES: 3L-L, 3L-T (DELTA
SYSTEM). -PROTECTION ELEMENTS DIRECTLY CONNECTED IN ALL MODES (6 MODES
DELTA SYSTEMS) ACCORDING TO NEMA LS-1 IEEE STD 1100-2005. LISTED TO UL1449 3RD
EDITION (SEPT. 2009) BY CSA, AN NRTL, ANSI C62.45, CSA MC#214804, UL1283 AND CE
COMPLIANT, ISO 9001:2000, ANSI C62.72-20071I2-CATEGORY. -FOR USE WITH ANSI
C62.41.1 C3 AND C62.41.2-2002. -ELECTRONIC COMPONENTS ENCAPSULATED IN RESIN
OF DISSIPATION. THERMAL FUSE BUILT-COMPONENT LEVEL TO PROVIDE SECURITY AND
INTEGRITY OF STAFF TO THE TEAM (THE SPD DID NOT EXPLODE), FUSE 200KA INTERNAL
OVER CURRENT. NOMINAL DISCHARGE-TEST IN = 20KA, VPR = 1800V ACCORDING TO
ANSI / UL 1449, 2006, THIRD EDITION IN PLACE SINCE SEPTEMBER 9, 2009 AND THE NEC,
2008. -NEMA 4 ENCLOSURE. –RESPONSE TIME <1 NANOSECOND. - COMPREHENSIVE
WARRANTY 25 YEARS MANUFACTURING FAULT AND / OR ANY INTERNAL OR EXTERNAL
ELECTRICAL ANOMALY.
SUPRESOR DE 180 KA. PARA PROTEGER LA ELECTRÓNICA FUERZA O POTENCIA DEL
VARIADOR. LA-ST180 3N4
TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST TRANSIENT INPUT
AND LIGHTNING. -DISCHARGE CAPACITY: 180 KA PER PHASE (EXCLUSIVE) : TRANSIENT
VOLTAGE SUPPRESSOR, INSTALLED CASCADE UNIT, INPUT VOLTAGE 480 (DELTA). WITH
KIND AND INSTALLATION. FEATURES: INPUT VOLTAGE: 480 VAC, 3F (DELTA) (03 + PE). DISCHARGE CAPACITY: 180 KA PER PHASE. -DIAGNOSIS OF CIRCUITS: BRIGHT LED,
NORMALLY ON. -6 PROTECTION MODES: 3L-L, 3L-T. -PROTECTION ELEMENTS DIRECTLY
CONNECTED IN ALL MODES (6 MODES DELTA SYSTEMS) ACCORDING TO NEMA LS-1 IEEE
STD 1100-2005. LISTED TO UL1449 3RD EDITION (SEPT. 2009) BY CSA, AN NRTL, ANSI
C62.45, CSA MC#214804, UL1283 AND CE COMPLIANT, ISO 9001:2000, ANSI C62.72-20071I2CATEGORY. -FOR USE WITH ANSI C62.41.1 C3 AND C62.41.2-2002. -ELECTRONIC
COMPONENTS ENCAPSULATED IN RESIN OF DISSIPATION. THERMAL FUSE BUILTCOMPONENT LEVEL TO PROVIDE SECURITY AND INTEGRITY OF STAFF TO THE TEAM
(THE SPD DID NOT EXPLODE), DOWNLOAD COUNTER-DISPLAY. -CARD AND DRY
CONTACT TO EXPORT COUNT DOWNLOADS TO THE DRIVE. FREQUENCY ATTENUATION
NETWORK TECHNOLOGY. .INTERNAL FUSE OVER CURRENT DISSIPATION CAST RESIN.
DRY CONTACTS FOR ALARM-NA AND NC (STANDARD OPTION C). -NEMA 4 ENCLOSURE.
INTERNAL FUSE 200KA OVER CURRENT. NOMINAL DISCHARGE-TEST IN = 20KA, VPR =
1800V ACCORDING TO ANSI / UL 1449, 2006, THIRD EDITION IN PLACE SINCE SEPTEMBER
9, 2009 AND THE NEC, 2008. -RESPONSE TIME <1 NANOSECOND. - COMPREHENSIVE
WARRANTY 20 YEARS MANUFACTURING FAULT AND / OR ANY INTERNAL OR EXTERNAL
ELECTRICAL ANOMALY.
SUPRESOR DE 120 KA. PARA PROTEGER LA ELECTRÓNICA DE FUERZA O POTENCIA DEL
VARIADOR. LA-ST120 3N4
TRANSIENT VOLTAGE SURGE SUPPRESSORS. PROTECTION AGAINST TRANSIENT INPUT
AND LIGHTNING. -DISCHARGE CAPACITY: 120 KA PER PHASE (EXCLUSIVE) : TRANSIENT
VOLTAGE SUPPRESSOR, INSTALLED CASCADE UNIT, INPUT VOLTAGE 480 (DELTA). WITH
KIND AND INSTALLATION. FEATURES: INPUT VOLTAGE: 480 VAC, 3F (DELTA) (03 + PE). DISCHARGE CAPACITY: 180 KA PER PHASE.
-DIAGNOSIS OF CIRCUITS: BRIGHT LED, NORMALLY ON. -6 PROTECTION MODES: 3L-L, 3LT. -PROTECTION ELEMENTS DIRECTLY CONNECTED IN ALL MODES (6 MODES DELTA
SYSTEMS) ACCORDING TO NEMA LS-1 IEEE STD 1100-2005. LISTED TO UL1449 3RD
EDITION (SEPT. 2009) BY CSA, AN NRTL, ANSI C62.45,CSA MC#214804, UL1283 AND CE
COMPLIANT, ISO 9001:2000, ANSI C62.72-20071I2-CATEGORY. -FOR USE WITH ANSI
C62.41.1 C3 AND C62.41.2-2002. -ELECTRONIC COMPONENTS ENCAPSULATED IN RESIN
OF DISSIPATION. THERMAL FUSE BUILT-COMPONENT LEVEL TO PROVIDE SECURITY AND
INTEGRITY OF STAFF TO THE TEAM (THE SPD DID NOT EXPLODE), DOWNLOAD COUNTERDISPLAY. -CARD AND DRY CONTACT TO EXPORT COUNT DOWNLOADS TO THE DRIVE.
FREQUENCY ATTENUATION NETWORK TECHNOLOGY. .INTERNAL FUSE OVER CURRENT
DISSIPATION CAST RESIN. DRY CONTACTS FOR ALARM-NA AND NC (STANDARD OPTION
C). -NEMA 4 ENCLOSURE. INTERNAL FUSE 200KA OVER CURRENT. NOMINAL DISCHARGETEST IN = 20KA, VPR = 1800V ACCORDING TO ANSI / UL 1449, 2006, THIRD EDITION IN
PLACE SINCE SEPTEMBER 9, 2009 AND THE NEC, 2008. -RESPONSE TIME <1
NANOSECOND. - COMPREHENSIVE WARRANTY 20 YEARS MANUFACTURING FAULT AND /
OR ANY INTERNAL OR EXTERNAL ELECTRICAL ANOMALY.
SUPRESOR DE 60 KA. PARA PROTEGER LA ELECTRÓNICA DE CONTROL DEL VARIADOR.
ST-SPT120-15
PROTECTION AGAINST TRANSIENT INPUT AND LIGHTNING. -DISCHARGE CAPACITY: 60 KA
PER PHASE. (EXCLUSIVE) : TRANSIENT VOLTAGE SUPPRESSOR, A UNIT INSTALLED AT
THE OUTLET OF 120 VAC CONTROL TRANSFORMER, 1F, 60 HZ. FEATURES: INPUT
VOLTAGE: 120 VAC, 1F (PHASE + NEUTRAL + EARTH)-DISCHARGE CAPACITY: 60 KA PER
PHASE. -DIAGNOSIS OF CIRCUITS: BRIGHT LED, NORMALLY ON. -PROTECTION MODES: L N, L - G, N - G. -PROTECTION ELEMENTS CONNECTED IN ALL MODES ACCORDING TO
NEMA LS-1 IEEE STD 1100-2005. LISTED TO UL1449 3RD EDITION (SEPT. 2009) BY CSA, AN
NRTL, ANSI C62.45, CSA MC#214804, UL1283 AND CE COMPLIANT, ISO 9001:2000, ANSI
C62.72-20071I2-CATEGORY. -FOR USE WITH ANSI C62.41.1 C3 AND C62.41.2-2002. ELECTRONIC COMPONENTS ENCAPSULATED IN RESIN OF DISSIPATION. THERMAL FUSE
BUILT-COMPONENT LEVEL TO PROVIDE SECURITY AND INTEGRITY OF STAFF TO THE
TEAM (THE SPD DID NOT EXPLODE OPTIMAL RESPONSE NETWORK AND ENHANCED
SINEWAVE TRACKING. INTERNAL FUSE OVER CURRENT DISSIPATION CAST RESIN. -NEMA
4 ENCLOSURE. -RESPONSE TIME <1 NANOSECOND.COMPREHENSIVE GUARANTEE 25
YEARS MANUFACTURING FAULT AND / OR ANY INTERNAL OR EXTERNAL ELECTRICAL
ANOMALY.
SUPRESOR DE 60 KA. PARA PROTEGER LA ELECTRÓNICA DE CONTROL DEL VARIADOR.
ST-SPT240-30
PROTECTION AGAINST TRANSIENT INPUT AND LIGHTNING. -DISCHARGE CAPACITY: 60 KA
PER PHASE. (EXCLUSIVE) : TRANSIENT VOLTAGE SUPPRESSOR, A UNIT INSTALLED AT
THE OUTLET OF 240 VAC CONTROL TRANSFORMER, 1F, 60 HZ. FEATURES: INPUT
VOLTAGE: 240 VAC, (HOT + HOT + EARTH)-DISCHARGE CAPACITY: 60 KA PER PHASE. DIAGNOSIS OF CIRCUITS: BRIGHT LED, NORMALLY ON. -PROTECTION MODES: L - L, L - G.
-PROTECTION ELEMENTS CONNECTED IN ALL MODES ACCORDING TO NEMA LS-1 IEEE
STD 1100-2005. LISTED TO UL1449 3RD EDITION (SEPT. 2009) BY CSA, AN NRTL, ANSI
C62.45,CSA MC#214804, UL1283 AND CE COMPLIANT, ISO 9001:2000, ANSI C62.72-20071I2CATEGORY. -FOR USE WITH ANSI C62.41.1 C3 AND C62.41.2-2002. -ELECTRONIC
COMPONENTS ENCAPSULATED IN RESIN OF DISSIPATION. THERMAL FUSE BUILTCOMPONENT LEVEL TO PROVIDE SECURITY AND INTEGRITY OF STAFF TO THE TEAM
(THE SPD DID NOT EXPLODE), OPTIMAL RESPONSE NETWORK AND ENHANCED
SINEWAVE TRACKING. INTERNAL FUSE OVER CURRENT DISSIPATION CAST RESIN. -NEMA
4 ENCLOSURE. -RESPONSE TIME <1 NANOSECOND. COMPREHENSIVE GUARANTEE 25
YEARS MANUFACTURING FAULT AND / OR ANY INTERNAL OR EXTERNAL ELECTRICAL
ANOMALY.
SUPRESOR DE 10 KA. PARA PROTEGER LA DATA DEL VARIADOR. ST-CLP5A4DIN-B
PROTECTION AGAINST TRANSIENT INPUT AND LIGHTNING. -DISCHARGE CAPACITY: 10 KA
LL AND LG, (EXCLUSIVE) : TRANSIENT VOLTAGE SUPPRESSOR, A UNIT IN PARALLEL WITH
12 VDC INPUT VOLTAGE, RS-485 2 PAIRS. FEATURES: INPUT VOLTAGE: 12VDC. DISCHARGE CAPACITY: 10 KA LL AND LG-ANSI C62.41.1 CATEGORY B3/C1 AND C62.41.22002. -500MA OPERATING CURRENT. –MAXIMUM OPERATING VOLTAGE 15VDC-RESIN
TYPE. -UL 94-5VA ENCLOSURE. -RESPONSE TIME <1 NANOSECOND. COMPREHENSIVE
GUARANTEE 25 YEARS MANUFACTURING FAULT AND / OR ANY INTERNAL OR EXTERNAL
ELECTRICAL ANOMALY.
SUPRESOR DE 10 KA. PARA PROTEGER LA DATA Y COMUNICACIÓN CONEXIÓN RJ45.
ST-RJ45-CAT5E
SERIES WIRED TRANSIENT VOLTAGE SURGE SUPPRESSOR WITH ENCAPSULATED
OPTIMAL RESPONSE NETWORK CIRCUITRY FOR PROTECTION OF DATA CIRCUITS.
APPLICATION: DESIGNED FOR USE DATA, SIGNAL AND CURRENT LOOP CIRCUITS TO
PROTECT DATA TRANSMISSION SYSTEM EQUIPMENT FROM DAMAGING TRANSIENTS
GENERATED
BETWEEN
TERMINALS
AND
EQUIPMENT
IN
THE
DATA
COLLECTION/TRANSMISSION SYSTEM. WARRANTY: 10 YEARS UNLIMITED FREE
REPLACEMENT. CIRCUIT DESIGN: SERIES WIRED HYBRID DESIGN INCORPORATING
DISCRETE ALL MODE PROTECTION AND UTILIZING OUR OPTIMAL RESPONSE NETWORK
DESIGN TO PROVIDE LOWEST POSSIBLE LET-THROUGH VOLTAGES. PROTECTION
MODES: DEDICATED PROTECTION COMPONENTS AND CIRCUITRY FOR EACH MODE.
DISCRETE L-L (NORMAL MODE) AND L-G, SHIELD-G (COMMON MODE). MAXIMUM DATA
RATE: 100.0 MBPS
OPERATING VOLTAGE: 7.5VDC. OPERATING CURRENT: 360MA. MAXIMUM DATA RATE:
100.0 MBPS. PEAK SURGE CURRENT PER WIRE: 3KW PER WIRE. RESPONSE TIME: <1
NANOSECOND. ENCLOSURE: PLASTIC, UL 94V. MOUNTING VELCRO. CONNECTION
METHOD: RJ45 MODULAR CONNECTORS WITH ALL 8 PINS PROTECTED WITH A DATA
RATE OF 100MBPS.
SUPRESOR PARA PROTEGER CONTROL DC DEL VARIADOR. ST-SPT__DC3XX
SERIES WIRED PARALLEL-CONNECTED TRANSIENT VOLTAGE SURGE SUPPRESSOR WITH
ENCAPSULATED.OPTIMAL RESPONSE NETWORK, FREQUENCY ATTENUATION NETWORK
CIRCUITRY AND THERMALLY FUSED SUPPRESSION COMPONENTS.DESIGNED FOR USE
AT ANSI/IEEE CATEGORY A WITH SUSCEPTIBILITY UP TO MEDIUM EXPOSURE LEVELS TO
PROTECT SENSITIVE/CRITICAL LOADS FED BY A SINGLE DC CIRCUIT.WARRANTY: 25
YEARS UNLIMITED FREE REPLACEMENT.CERTIFICATIONS: IEC-61643-1 CLASS 3
ENCLOSURE: PLASTIC, UL 94VA EXTERNAL MOUNTING FEET. 3-LUG SCREW TERMINAL
STRIP AT BOTH THE INPUT AND OUTPUT SIDES OF THE DEVICE.SHIPPING WEIGHT: ≈
2LBS. SERIES WIRED, PARALLEL CONNECTED HYBRID DESIGN INCORPORATING
DISCRETE ALL MODE PROTECTION DESIGN TO PROVIDE LOWEST POSSIBLE LETTHROUGH-VOLTAGES. ALL SUPPRESSION CIRCUITS ARE COMPLETELY ENCAPSULATED
IN OUR EXCLUSIVE COMPOUND TO ASSURE LONG COMPONENT LIFE AND COMPLETE
PROTECTION FROM THE ENVIRONMENT AND/OR VIBRATION. DEDICATED PROTECTION
COMPONENTS AND CIRCUITRY FOR EACH MODE. DISCRETE P-N (NORMAL MODE), AND
DISCRETE P-G, N-G (COMMON MODE)
OPERATING TEMPERATURE: UP TO 80° C. CAPACITANCE: UP TO 7UF. MAX. OPERATING
CURRENT: 15 AND 30 AMPS. RESPONSE TIME: <1 NANOSECOND. CIRCUIT DIAGNOSTICS:
SUPER BRIGHT LED, NORMALLY ON. DIN OPTION. REMOTE ALARM OPTION: DRY RELAY
CONTACTS, 125VRMS, 0.5 AMPS; 30VDC, 1.0 AMPS – N/O, N/C. THESE CONTACTS ARE FOR
USE IN CONJUNCTION WITH EXTERNAL STATUS MONITORING DEVICES AND ARE
CONNECTED VIA THE 18GA WIRES PROVIDED.
SUPRESOR PARA PROTEGER LOS EQUIPOS REGISTRADORES DE PRESIÓN EN POZO DE
PETRÓLEO. (PIT). ST-CL__C-2
SERIES WIRED TRANSIENT VOLTAGE SURGE SUPPRESSOR WITH ENCAPSULATED
OPTIMAL RESPONSE NETWORK™ CIRCUITRY FOR PROTECTION OF CURRENT LOOP
CIRCUITS, SIGNAL LINES AND OTHER LOW SPEED DATA CIRCUITS. DESIGNED FOR USE
WITH DATA COLLECTION AND SWITCHING CIRCUITS TO PROTECT DATA TRANSMISSION
SYSTEM EQUIPMENT FROM DAMAGING TRANSIENTS GENERATED BETWEEN TERMINALS
AND EQUIPMENT IN THE DATA COLLECTION/TRANSMISSION SYSTEM. WARRANTY: 25
YEARS UNLIMITED FREE REPLACEMENT.ENCLOSURE: 316 STAINLESS STEEL. MOUNTING:
NPT THREADED HOUSING. CONNECTION METHOD: 18 AWG TINNED COPPER WIRE.
SHIPPING WEIGHT: 1LBS. SERIES WIRED HYBRID DESIGN INCORPORATING DISCRETE ALL
MODE PROTECTION AND UTILIZING OUR ENCAPSULATED OPTIMAL RESPONSE
NETWORK™ DESIGN TO PROVIDE LOWEST POSSIBLE LET-THROUGH VOLTAGES. ALL
SUPPRESSION CIRCUITS ARE COMPLETELY ENCAPSULATED IN OUR EXCLUSIVE
COMPOUND TO ASSURE LONG COMPONENT LIFE AND COMPLETE PROTECTION FROM
THE ENVIRONMENT AND/OR VIBRATION. PROTECTION MODES: DEDICATED PROTECTION
COMPONENTS AND CIRCUITRY FOR EACH MODE. DISCRETE L-L (NORMAL MODE) AND L-G
(COMMON MODE) OPERATING VOLTAGE: NOMINAL (MAXIMUM) 5V (7.5V), 12V (15V), 24V
(33V), 48V (53V), 140V (140V) MAXIMUM CONTINUOUS. OPERATING CURRENT:
430MA.FREQUENCY RANGE: DC TO 2MHZ. MAXIMUM DATA RATE: UP TO 200KBITS/SEC.
SERIES RESISTANCE: 10 OHMS PER LINE. PEAK SURGE CURRENT PER PAIR: L-L 20KA, LG 20KA. RESPONSE TIME: <1 NANOSECOND.
SUPRESOR DE 10 KA. TIPO TERMINAL PARA PROTEGER INSTRUMENTACION. ST-C__M4
TRANSIENT VOLTAGE SURGE SUPPRESSORS 10KA PROTECTION FOR 2 OR 4 WIRE
CIRCUITS ON DATA CIRCUITS UP TO 100MHZ. CLAMPING VOLTAGES (12 OR 24 VDC) ON
LOW LEVEL TRANSIENT EVENTS. LOW – 1 OHM – IMPEDANCE PER LINE. EXCELLENT 10
YEAR REPLACEMENT WARRANTY. CAPACITANCE LINE‐LINE C ≤ 20PF. CAPACITANCE
LINE‐PG C ≤ 25PF. RESPONSE TIME LINE‐LINE TA ≤1NS. RESPONSE TIME LINE‐PG TA
≤100NS. OPERATING TEMPERATURE RANGE ‐40℃...+80℃. CROSS‐SECTIONAL AREA
0.08MM2 ~ 4MM2 SOLID / 2.5MM2 FLEXIBLE. MOUNTING ON 35MM DIN RAIL. ENCLOSURE
MATERIAL BLACK THERMOPLASTIC, UL94‐V0.TEST STANDARDS IEC 61643‐21.