LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire PROJECT INFORMATION Project Name Type Catalog No. Date CONSTRUCTION FEATURES • High-performance LED luminaire • Long-life, 50,000 hour LEDs at L90 (90% lumen maintenance) reduce life cycle maintenance costs • DesignLights Consortium® qualified • Superior color consistency to a 3-step MacAdam ellipse and 82 CRI • Full distribution provides controlled high angle light for visual comfort • Lens design and materials provide uniform appearance without pixilation • Unique frameless optical system and modular electrical system allow for easy LED module or driver replacement from below the ceiling • Most configurations produce low W/ft2 to meet the most restrictive lighting power density codes • Available with exclusive wiHUBB technology preinstalled – Peer to peer, self-healing wireless mesh network – Integrated control system for 0-10VDC or step dimming, or On/Off • U.S. Transformed ORDERING INFORMATION LEPC 24 – Luminaire is available to fit exposed grid ceilings, or hard ceilings when a flange kit is ordered. For information on compatibility with specific ceilings, or where plenum depth is a problem, contact your Columbia Lighting representative. Four integral T-bar clips are standard. FINISH All luminaires are built to UL 1598 and 2108 standards,and bear appropriate CSA labels. Tested to LM79 and LM80 standards. Damp location labeling is standard. Emergency-equipped fixtures labeled UL 924. IC rating is standard on all models (Does not apply to thru-wiring). DesignLights Consortium® (DLC) qualified. Please refer to the DLC website for specific product qualifications at www. designlights.org. All visible parts are custom formulated soft, nonglare high-reflectance white powder coat finish, painted after fabrication. SHIELDING Lenses are high transmission extruded acrylic. INSTALLATION An access plate is furnished with each recessed fixture for fast wiring connections without the necessity to open the fixture or wireway. – CEILING COMPATIBILITY Luminaire housing, end caps, and reflectors are die-formed code-gauge cold-rolled steel. Frameless optics system hinges from either side for easy access to lamps and electrical components. Mechanical light trap prevents light leaks. Latches are spring loaded. Fixture construction is standard static. Air handling return air side slots are available as option. LL CERTIFICATION WARRANTY Five year warranty. (Terms and Conditions Apply) EXAMPLE LEPC24-35LWG-LL-EDU – U – MODEL COLOR TEMP CEILING TYPE AIR FUNCTION DRIVER VOLTAGE LEPC e∙poc® LED Full Distribution Luminaire 30 3000K 4 35 3500K 40 4000K G Grid SM Surface Mount For hard ceilings use flange kit. Blank Static A Air Return Side Slots ESD Fixed Output / Step Dimming1 ED 0-10V Dimming U 120V-277V SIZE 24 2' × 4' LUMEN OUTPUT LW Low Watt (4400 Lumens Nominal) HL High Lumen (6600 Lumens Nominal) SHIELDING LL Low Lamp Image OPTIONS C388 C488 C588 GLR NYC NYCU WIH RM ELL14 3-Wire Flex 4-Wire Flex 5-Wire Flex Fast Blow Fuse NYC Compliant NYC Compliant, Union Label wiHUBB Enabled 2,3 Row Mount Emergency Battery Pack Installed, 1400 Lumens4 ACCESSORIES (ORDER SEPARATELY) FK24 2' ×4' Single Flange Kit FKCR Flange Kit Row Adaptor Can be converted to fixed output by tying the hot leads together. In-Fixture Module Antenna adds 2" to overall fixture height at specific location. Not available with Surface Mount ceiling types. 4 For compatibility with Dual-Lite LiteGear® inverters in lieu of installed Battery Pack, contact Hubbell Lighting Representative. 1 2 3 Damp Label - standard IC Rating - standard (no thru-wiring) Protected by US Patents D603,999; D604,446. Additional US and Canada Patents Pending. Specifications subject to change without notice. Page 1/3 Rev. 01/09/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com RECESSED ARCHITECTURAL / LEPC24 LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire PHOTOMETRIC DATA Test ITL73228 Test Date 6/13/2012 LUMINAIRE DATA ZONAL LUMEN SUMMARY Zone LEPC24-35LWG-LL-ESD LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lenses (2) D150CQ25UNVA-A 1.00 LED 4399 40.50 0º = 90 90º = 90 0º = 1.18 90º = 1.25 Length: 3.83 Width: 1.85 Height: 0.00 Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet ENERGY DATA Lumens % Lamp % Fixt. 0-30 1242 28.2 28.2 0-40 2012 45.7 45.7 0-60 3497 79.5 79.5 0-90 4399 100.0 100.0 0-180 4399 100.0 100.0 INDOOR CANDELA PLOT RCR 80 50 104 91 80 71 63 57 52 47 43 40 30 100 84 72 62 54 48 43 39 35 32 10 96 78 65 55 48 42 37 33 30 27 70 106 96 88 80 74 68 64 59 55 52 70 50 102 89 78 69 62 56 51 47 43 40 30 98 83 71 61 54 48 43 38 35 32 10 95 77 65 55 47 41 37 33 30 27 50 98 85 75 67 60 54 49 45 42 39 50 30 94 80 69 60 53 47 42 38 34 32 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE: Comparative Yearly Lighting Energy Cost per 1000 Lumens 109 75 0 10 0 92 84 76 70 64 59 54 51 47 44 41 38 36 34 33 30 29 27 27 25 850 60 0.0 22.5 45.0 67.5 0 2469 2469 2469 2469 2469 30 2265 2289 2319 2377 2394 40 2096 2130 2215 2320 2372 45 1996 2039 2155 2301 2368 50 1872 1947 2101 2302 2378 55 1777 1859 2076 2320 2426 60 1659 1765 2048 2346 2422 65 1542 1675 2056 2239 2243 70 1426 1630 1994 1994 1870 75 1350 1608 1825 1632 1514 80 1225 1557 1470 1234 1137 85 1150 1290 959 697 593 15 0.0 30 Horiz 0-180 45.0 90.0 Test ITL73733 Test Date 7/27/2012 ZONAL LUMEN SUMMARY LLEPC24-35HLG-LL-ESD LEPC Epoc LED Full Distribution, Recessed Architectural 2 x 4 LED with frosted linear prismed lens (2) D255CQ42UNVA-A 1.00 LED 6966 66.10 0º = 90 90º = 90 0º = 1.18 90º = 1.25 Length: 3.83 Width: 1.85 Height: 0.00 Zone ENERGY DATA Lumens % Lamp % Fixt. 0-30 1969 28.3 28.3 0-40 3187 45.7 45.7 0-60 5537 79.5 79.5 0-90 6966 100.0 100.0 0-180 6966 100.0 100.0 INDOOR CANDELA PLOT RCR 80 50 30 104 100 91 84 80 72 71 62 63 54 57 48 52 43 47 39 43 35 40 32 10 96 78 65 55 48 42 37 33 30 27 70 106 96 88 80 74 68 64 59 55 52 70 50 30 102 98 89 83 78 71 69 61 62 54 56 48 51 43 47 38 43 35 40 32 10 95 77 65 55 47 42 37 33 30 27 50 98 85 75 67 60 54 49 45 42 39 50 30 95 80 69 60 53 47 42 38 34 32 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance 0 10 0 92 84 76 70 64 59 54 51 47 44 41 38 36 34 33 30 29 27 27 25 100.0% Total Lumens per Watt ANSI/IESNA RP-1-2004 COMPLIANCE: Comparative Yearly Lighting Energy Cost per 1000 Lumens 105 Noncompliant $2.26 based on 3000 hrs. and $0.08 per KWH AVG. LUMINANCE (Candela/Sq. M.) 0.0 22.5 45.0 67.5 0 3919 3919 3919 3919 3919 30 3578 3622 3671 3764 3798 40 3320 3375 3514 3681 3762 45 3158 3216 3414 3650 3762 50 2971 3082 3325 3651 3779 55 2807 2929 3268 3679 3840 3843 90 75 COEFFICIENTS OF UTILIZATION (%) 70 109 99 90 83 76 70 65 61 57 53 Total Luminaire Efficiency 1300 60 Average Luminance Angle LUMINAIRE DATA RC RW 1 2 3 4 5 6 7 8 9 10 90.0 45 PHOTOMETRIC DATA Ballast Ballast Factor Lamp Fixture Lumens Watts Shielding Angle Spacing Criterion Luminous Opening in Feet $2.18 based on 3000 hrs. and $0.08 per KWH 1700 0 RCR = Room Cavity Ratio RC = Effective Ceiling Cavity Reflectance RW = Wall Reflectance Luminaire Noncompliant AVG. LUMINANCE (Candela/Sq. M.) 90 COEFFICIENTS OF UTILIZATION (%) RC RW 70 1 109 99 2 90 3 83 4 76 5 70 6 65 7 61 8 57 9 10 53 Total Luminaire Efficiency Average Luminance Angle Luminaire 90.0 60 2613 2774 3227 3701 65 2423 2649 3242 3573 3541 70 2234 2585 3163 3180 2963 75 2095 2547 2905 2624 2389 80 1933 2450 2336 1995 1811 85 1708 1987 1464 1081 906 2600 0 15 0.0 30 Horiz 0-180 45.0 Page 2/3 Rev. 01/09/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com 45 90.0 RECESSED ARCHITECTURAL / LEPC24 LEPC24 2' × 4' LED, e•poc® Full Distribution Luminaire DIMENSIONAL DATA - GRID CEILING COMPATIBILITY Type G FKCR 33/8" 24" Side End For lay-in installation in exposed grid ceilings. Maximum tee widths of 1" and maximum tee heights of 2" allowed. 24" For flanged fixtures in row configurations, the FKCR adapter bracket kit is required in addition to the FK24 kit. Order one less FKCR than the total number of fixtures in row. (Example: Row of two, order (2) FK24 & (1) FKCR) FK24 Flange Kit 48" Side For hard ceiling applications, order FK24 flange kit. Flange kit wires directly into concealed ceiling opening for a clean, finished appearance. DIMENSIONAL DATA - SURFACE MOUNT 4.244 3.01 5.770 5.000 End 9.920 Row cut out dimensions using FK24s & FKCR adapters: Width 243/8", Length [48" × (# in row)] + 3/8". Example: (48" × 2) + 3/8" = 963/8" Flange kit cut out dimension for single unit only: 243/8" × 483/8" 3.01 4.500 4.270 48.850 .250 KOS 4 PLCS 2.98 2.98 4.270 4.244 3.776 25.015 NOTE: All dimensions are in inches; dimensions and specifications are subject to change without notice. Please consult factory or check sample for verification. Page 3/3 Rev. 01/09/14 © 2014 Columbia Lighting, a division of Hubbell Lighting, Inc. Specifications subject to change without notice. 701 Millennium Blvd. Greenville, SC 29607 / Tel 864.678.1000 / Website www.columbialighting.com RECESSED ARCHITECTURAL / LEPC24